Setting up the S_tcode Range of T code

Friends
I am trying to remove OBR1 OTZ1 and OBR3 transactions from Transaction Range that I have for the S_TCODE.
I tried to put below range but user still can execute the above transactions.
OA*        OBQ*
OBR2
OBR4     OBY1
OBY3     OTY*
OTZ2     OZZZ*
Any suggestions?
Form
Praveen

Think about it....
How would you react to these to options if you were a kernel:
'OA*' to 'OBQ*'
and...
'OA' to 'OBQ*'
Should there be a difference and what is it? This is one of the dangers of 'ranging*' without reading the documentation carefully.
Most likely you will have several other (possibly bigger) problems of the same ilk in your system.
Cheers,
Julius

Similar Messages

  • How to setting for the number range for Business Partner

    Dear Sir,
    I create the new role for Business Parnter , However, I would like to set the new number range for that buiness Partner with that role.
    Please kindly advise what is the step to do.
    Thank you and best regards,
    Vimol

    Hi Vimol,
    In CRM  standard system it is not possible to link specific role with specific grouping. 
    To achive the same go to following IMG path:
    SAP Implementation Guide>Cross-Application Components>SAP Business Partner>Business Partner>Basic Settings>Number Ranges and Groupings>
    Define Groupings and Assign Number Ranges
    Hope you selected the opton button for column 'Int Std.
    I already suggested a work around above.
    Best Regards,
    Satish Mathala

  • MN05: setting the number of printer copies for the whole range of vendors

    Hi all,
    by t.code MN05 I can set the number of copies of the MM documents printed the FIRST TIME. I can do it for doc.type or vendor.
    I can't set the number of printer copies for the whole range of vendors. Should I do it for each one of them?
    Thanks
    Gandalf

    Unfortunately,
    setting for document type, it doesn't work for all range of vendors.
    Setting for document type, in the field "PartF" I've put in "OA". Could it depend on it?
    you do for document type and then it will cover all range of vendors.
    If you want prints for a specific vendor then set condition recrod for that vendor only.
    regards

  • In Labview 8.5, what happens if the signal input exceeds the signal input range set by the DAQ Assistant?

    Hello all,
    This should be a pretty simple question, but I can't seem to find the answer on-line and don't currently have the capabilities to test this:
    I'm using LabVIEW 8.5 and have a VI that imports sensor data through the DAQ Assistant. In the configuration tab there is a signal input range. What happens if my sensor exceeds this range? Will I get a warning? Will the value default to the maximum (or minimum)? I was interested in writing in some code to display an error as I approach the limits of this range, but was unsure if I also needed to include some code to display an error if the range is exceeded as well.
    Thanks for the help,
    Tristan
    Solved!
    Go to Solution.

    Hello Tristan,
    The behavior depends on the range you choose and the device you are using.
    If you are using a device with only one valid input range, we will use this range even if you set a smaller minimum and maximum in the DAQ Assistant.  Thus, if your device only supports ±10V and you set the range to ±8V, you will still continue to get valid data after your sensor exceeds 8V until you approach 10V.  Once you reach the limit of the range of your device, the output will "rail" and just return the maximum value until the signal drops below the maximum again.
    Note: A device that is nominally ±10V usually has some overshoot (like ±10.2V) that is typically specced in the manual.
    However, if you are using a device with multiple input ranges then things get more complex.
    The NI-DAQmx drive will pick the smallest range that fully encompasses the range you choose.  So, suppose your device supports the following input ranges: ±0.2V, ±1, ±5V, and ±10V and you choose 0V - 3V as the range in the DAQ assistant.  The NI-DAQmx driver is going to look at your input range and the list of input ranges that your hardware supports and choose the smallest that encompasses the full range you set.  This would the ±5V, because that's the only range that contains up to 3V.  As a result, any input signal between ±5V will be returned and any outside this range will "rail" to either the maximum or minimum value.
    We do this because using smaller ranges make more effective use of the resolution of the ADC.  Thus we try to use the most efficient range based on what you request without picking a range that will cause you to miss data.
    Let me know if I can clarify this further. 
    Seth B.
    Staff Test Engineer | National Instruments
    Certified LabVIEW Developer
    Certified TestStand Developer
    “Engineers like to solve problems. If there are no problems handily available, they will create their own problems.”- Scott Adams

  • Setting a particular value as default for the Grouping Range at BP Creation

    Hi,
    I am trying to set certain default for the Grouping Range when I create a new Bp using Tcode BP. For this i have changed the PBC fucntion for the view BUP020 ( TCode : BUS3). The Z function module attached is Z_FBSBP_SET_DEFAULT_GROUPING
    FUNCTION z_fbsbp_set_default_grouping.
    ""Local interface:
    *"  IMPORTING
    *"     REFERENCE(IV_ACTION) LIKE  BUS000FLDS-CHAR1
    *"     REFERENCE(IV_SICHT) TYPE  BU_SICHT
      DATA: lv_bu_group TYPE bu_group VALUE 'GR01'.
    Set the Grouping Range with a default value for all roles, each time
    when transaction BP is called
      SET PARAMETER ID 'BPP' FIELD lv_bu_group.
    Call the standard PBC fucntion module for BP Creation
      CALL FUNCTION 'BUP_BUPA_PBC_MISC'
        EXPORTING
          i_action = iv_action
          i_sicht  = iv_sicht.
    ENDFUNCTION.
    As per my notion this fucntion module should get triggered once I open the transaction BP and try to create a new BP, but such a thing is not happening.
    Can someone help me in this?
    Regards
    Priyanka

    Yes we did,
    But its not a very good solution though it serves the purpose.
    See what I did was:
    1. Read the authorization object's values for the logged on user using SUSR_USER_AUTH_FOR_OBJ_GET. From here I retrieve the Grouping Range required for the user.
    2. Keep this value in a variable say gv_grouping_range.
    3. SET PARAMETER ID 'BPP' FIELD gv_grouping_range.
    4. CALL TRANSACTION 'BP'.
    The four steps above have been enclosed in a report which has been attached to a new transaction code. We from now on allow user an access to this new transaction and not the standard BP transaction(which of course calls for a major change in roles).
    Secondly, the first three steps which have been enclosed in a subroutine set_default_grouping are also called from the BDT view BUP050, where the PBO has been changed to ZBUP_BUPA_PBO_MISC
    FUNCTION zbup_bupa_pbo_misc .
    ""Local interface:
    *"  IMPORTING
    *"     VALUE(I_SICHT) TYPE  BU_SICHT
    PERFORM get_set_def_grouping IN PROGRAM zrpbsbp_create_businesspartner.
      CALL FUNCTION 'BUP_BUPA_PBO_MISC'
        EXPORTING
          i_sicht = i_sicht.
    ENDFUNCTION.
    Hope this helps.
    Regards
    Priyanka

  • I wish to reset my ipad.  However, when I selectGeneral Reset Erase all content and Settings, I am prompted for a a Restrictions Passcode (which I have never set).  I have now entered random codes 11 times and the ipad not reset. How do I get past this?

    I wish to reset my ipad (as advised by the Apple Store) to attempt to resolve an issue with a non-responsive part of the screen..  However, when I select General>Reset>Erase all content and Settings, I am prompted for a a Restrictions Passcode (which I have never set).  I have now entered random codes 11 times and the ipad has not reset. How do I get past this?  I am now at the point where I have to wait 60 mins before I can enter another random passcode.  I just want the ipad to clear down, erase everything so I can start again.

    The other option is to force iPad into Recovery Mode.
    http://support.apple.com/kb/HT1808
    Note: You need to be patient and repeat the above many times to recover your iPad

  • HOW TO set the input range for analog in (DAQ)?

    How can I set the input range of a - NI DAQ USB 6259 - analog voltage input?
    I wish to control it directly in my VI. Is it possible to set different ranges for different input channels?
    Thank you,
    Roberto

    duplicate post

  • How to set FBL1N T code Layout to default to all the users using this T cod

    Dear Friends
    I have created a new layout by modifying the some of the fields in FBL1N T code output.  I want to set as default layout to all the users using this T Code. Is there any way we can set the  custom layout as default layout  to all the users.
    Presently Only I can see as default layout but  not the other users
    Thanks in Advance
    Thanks
    MVS

    Hi
    I have one above like issue but in FB03, I have been one layout as default using -lay admin when i come back and re execute the
    FB03 transaction  the default lay out not working directly every time i have to  "display as list from the" Go to" menu then only
    document showing as per lay out..I want  that lay out has to be work with out  going to Dispaly as list
    please advice me where i did wrong .its not working  even after the changes i log out the from the SAP and re login
    thanks
    Ranamka
    Edited by: Ranamka on Mar 10, 2011 9:59 PM

  • Can someone pls explain what the Dynamic Range setting does?

    Hello All,
    In the STB's Audio menu there's an option for Dynamic Range.  The available settings for Dynamic Range are None, Light, or Heavy.   I'm not noticing any difference in the sound regardless of the option chosen.   What is this option supposed to do?  

    http://en.wikipedia.org/wiki/Dynamic_range gives you a bit of a winded explantion of what it is.  In a nutshell dynamic range is the difference between the quietest and loudest sound.
    I beleive the dynamic range setting is designed is to help users that have a certain connections (eg HDMI) deal with fluctationing volume.  Heavy compresses the highs and lows to a narrower range, light uses less compression and none of course is no change.  If you have trouble hearing some channels and commercials are loud you might want to try heavy.  Keep in mind that heavy distorts audio the most and none the least.
    My audio system is a Pioneer Amp with a Polk 5.1 speaker system.  I've noticed no difference but to be fair I don't think I've tried it under condtions that I would notice it.  In addition I'm currently using an optical connection for my audio which apparently doesn't change with dynamic range.
    There is a few other threads that discuss this including ....
    http://forums.verizon.com/t5/FiOS-TV-Technical-Assistance/anyone-else-having-problems-with-volume-ou...
    http://forums.verizon.com/t5/FiOS-TV-Technical-Assistance/Intermittent-Audio-Distortion-with-HDMI-ho...

  • Printing - how to set the page range in the page format dialog?

    Hi
    I need to print the text in a JTextArea; and this text can be more than 1 page. I use MyPrinterJob.setPrintable(new MyPrintable()), and I can print the whole document. But the range of the page in the page format dialog ( which I make appear before the print dialog) is from 1 to 9999. How can we get rid of this and can make the range of page equal the number of pages in a document?
    If I use a Book, how can we set up the range of page in the dialog equal the number of pages in a document or in a JTextArea( assume we do not know how many pages it has at the beginning?)
    I would be thankful if anyone can help me.
    Thank you very much

    All fields in InDesign can be entered in any measurement system. So, if you want to make an 8"x10" document and go to File>New Document and the window looks like this:
    …you can type either 8 in or 8" into the Width field like this:
    …and when you move to the next field, it will convert the eight inches into the equivalent number in the unit of measure that it is using at the moment, like this:
    … (203.2 milimeters is the same as 8 inches). You can also enter a different measurement unit into other fields once the file is created, such as the width or height of a frame, or the position of an object in the X and Y coordinates.
    If you would rather just work in inches instead of having to type the inches mark or abbreviation, go to InDesign>Preferences>General and select the Units & Increments tab. There you will see Ruler Units for Horizontal and Vertical at the top of the window. Set them to Inches and all of the fields will display in inches. If you do that to an open document, you will change the unit of measure for that document. If you do it while no documents are open, it will change the unit of measure for any new documents you create. To change the unit of measure for existing documents, you will have to open each and make the change.

  • T.code F-01, error message  F5150: the number range ...  is missing

    Hi All,
    creating by F-01 a 'sample document', SAP gives me the message F5150: "... the number range ...  is missing ..."
    But in OBA7 and FBN1 I can't find the missing range.
    Is there a different customizing step to create a range for sample document?
    Thanks
    Gandalf

    Refer this link.
    http://help.sap.com/saphelp_erp60_sp/helpdata/EN/96/8b434c43ce11d189ee0000e81ddfac/frameset.htm
    You can basically use the sample document as a reference while posting an accounting document.  Use T Codes FBR1/FBR2.

  • How can I set the polarity / range of NI 6014 for 0.0V - 10V?

    How can I set the polarity / range of NI 6014 for 0.0V - 10V?

    Nilton,
    The NI 6014 only has bipolar (10V to -10V) mode available, not unipolar (10V to 0V). Look into our E Series boards for both unipolar and bipolar operation.
    Ames
    Applications Engineering
    National Instruments

  • How is to set the input range of PCI-MIO-16E-1 (6070E) to be 0 to +5V?

    How is to set the input range of PCI-MIO-16E-1 (6070E) to be 0 to +5V? Thank you very much.

    Hi x2am,
    Here is a link to a document about setting input range limits.
    DAQ Input Limits
    Hope this helps!
    Jeremy L.
    National Instruments
    Jeremy L.
    National Instruments

  • I have downloaded a Maverick OS X 10.9.4 and installed it on my Mac from a USB, and i can't receive a Verification Code via SMS when setting up the iCloud Keychain. Please help

    I have downloaded a Maverick OS X 10.9.4 and installed it on my Mac from a USB, and i can't receive a Verification Code via SMS when setting up the iCloud Keychain. Please help.

    Hello, Kutoz. 
    Thank you for visiting Apple Support Communities. 
    Here is some information that you may find helpful with this issue. 
    I'm not receiving the verification code via SMS.
    Make sure that you have a strong cellular network connection on your phone.
    Make sure that your phone number can receive SMS messages. You can do this by asking someone to send you a text message.
    Make sure that the correct phone number is associated with your account:
    iOS 7.0.3 or later: Tap Settings > iCloud > Account, then tap Keychain. Make sure the phone number under Verification Number is correct. If not, enter another phone number.
    OS X Mavericks v10.9 or later: Choose Apple () > System Preferences. Click iCloud, then click Account Details. Make sure the phone number listed under Verification number is correct. If not, enter another phone number.
    If you can't access a device that has iCloud Keychain enabled, you can contact Apple Support and verify your identity to get help completing iCloud Keychain setup.
    Get help using iCloud Keychain
    http://support.apple.com/kb/TS4644
    Cheers,
    Jason H. 

  • How to Off set the variable range ?

    experts !
    i have created a variable on ofiscper, and it gives a range for that. (  e.g. 001/2009 - 012/2009 ) . everything works good. but i have to show values for the same range for previous year too.. so i thought that off set should be working. But i am not gettting the correct results if i use off set to ( -1 ).
    can we use offset for a variable whcih takes range ?
    what are my options ?
    Thaks

    Hi honar,
        1. Take that  0fiscper In Characteristic Restrictions box.
        2. Right click on it choose Restrict option. you will get a window select variabls option.
        3. You may have predefined variable. Take that into selection box.
        4.Take the Offset value -12.
    Note : Make sure that your variable should be Intervel option  in variable Represents.
    This may resolve ur prob.
    Thanks,
    Mahi.

Maybe you are looking for

  • Error while starting OMS during installation of Enterprise Manager12c

    Hello Guys, I am trying to install Oracle Enterprise Manager 12c(64bit) on OEL5.2(64bit), but after successfully going through all the per-requisites of the installation; the installation fails at 89% "Start Oracle Management Service" phase and at "A

  • Installed Windows 7 on iMac. No sound.

    How do I get the sound to work? Reinstall the drivers for the sound card?  Update boot camp? The instructions are not very clear on updating your version of boot camp. Do I do it on the mac side or when I boot up Windows? Thanks in advance! Clay     

  • I have 2 Mac laptops, a Wacom tablet, extenal keyboard

    I have a Mac iBook G4 with phothsop CS2 installed and a MacBook Pro with with the external keyboard and Wacom tablet. (Wacom drivers no longer work on G4). Is it possible to use theh photoshop software on the MacBook Pro if both computers are connect

  • LabVIEW Mac prompting me for dll's in conditional disable structure

    I'm using LabVIEW 2014 Mac and I have several conditional disable structures which call user32.dll but only in the Default case whereas they do nothing in the TARGET_TYPE=Mac case.  When loading my source code in LV Mac I get prompted to find "user32

  • Field "Reference" in MIRO