Shared variable synchronization

Hi,
I am trying to send data between computers. I have used shared variable to do this and to avoid race condition I have append "?sync=true" in URL to synchronize access to shared data.  But when I run  Send and Read VI, race condition sometimes still appears? Even when I run both VIs on same PC.
I have attached VIs, if someone would like to try it.
Thanks,
andrej
Attachments:
SV.zip ‏53 KB

You maybe running into a race condition even though you are appending
the '?sync=true' tag is because the synchronous operation only ensures
that the dataflow proceeds after the the datasocket has communicated the
update to the shared variable engine. The race condition maybe caused
due to the time that the shared variable engine takes to update the
variable. The second iteration of the while loop may still read the
value of the SVRead variable from the previous iteration which might
cause a race condition. To avoid this possibility, I implemented a
tri-state SVRead variable. Instead of using a boolean, I used an
integer to check the status so that the Sender/Receiver do not wait for
the same value of SVRead which could potentially cause a race condition.
Assuming that the SVRead variable will be initialized to a '0' Value,
refer to the following image for more information on how the SVread
values are being cycled.
Also, I am attaching the editted version of your VIs so that you can test it out.
Please let me know if this helps in resolving the race condition.
Mehak D.
Attachments:
SV.zip ‏84 KB

Similar Messages

  • How do you synchroniz​e accesses to a LabVIEW Shared Variable?

    I would like to create an ad-hoc weather station program (I'll explain more in a bit).  I am using LabVIEW 8.0 Full Edition, and I would like to share data over a network between stations with the LabVIEW Shared Variable.  Here's what I want to be able to do:
    A node would start up, and begin publishing data to a network via a shared variable.
    The shared variable is an array of clusters
    The cluster information would hold things like:
    Station Name
    Station Location
    Weather information cluster (temperature, rainfall, windspeed, wind direction, etc...)
    Timestamp of last update
    When a new node would like to enter, it would bind to the shared variable, grow the array, and add its information.
    If a node's Station Name and Station Location is already in the shared variable, it would merely update the information in the cluster.
    Viewing nodes could pop in, bind to the shared variable, and read/display the information at any time. 
    I am trying to enumerate problems with this before implementing, and I have run into a stinker of a problem that I am not sure how to solve.  How do I synchronize accesses to the LabVIEW Shared Variable?  If I read the variable, modify it, and write it back, I will undoubtedly run into a race condition where 2 nodes attempt to update its data and I will lose the data written by the first node - Node A reads, Node A modifies, Node B reads, Node A writes, Node B Modifies, Node B Writes, and thus the modifications made by Node A are lost.  In my specific application losing some data isn't critical, but if not remedied this type of problem could cause massive amounts of data to be lost when there are numerous nodes, and that is definitely not acceptable. 
    Does anyone have any recommendations on how to synchronize the read-modify-write operations on the data in the Shared Variable?
    -Danny

    Wendy,
    I am afraid Semaphores are not network-shared objects (to my knowledge), they are system-level objects that use operating-system synchronization mechanisms.  If I were synchronizing on a single machine, a semaphore might be a valid mechanism; as an aside, most user-mode semaphores are designed to synchronize within a single process - to synchronize between processes you need to store the semaphore in the Kernel, and to synchronize over a network you would need a network node to handle serialization of requests.  My Shared Variable is published over a network, and to my knowledge there are no network-published synchronization mechanisms available - mostly because there is no way to currently perform an atomic test-and-set on the Shared Variable (am I correct?) and there isn't a mechanism for blocking access to a Shared Variable from another network device/machine (or is there?).  I've been looking for some way to implement an atomic test-and-set but I am running into a wall; I know that if I select the "single writer" attribute of the Shared Variable I can get LabVIEW to force a single writer allowing me to have an atomic "set", but I need more than that.
    If only there was a network-shared Semaphore or some way to block other network accesses to the Shared Variable I would be in business - something like what I want doesn't exist, does it?
    Thanks!
    -Danny
    Message Edited by texasdiaz on 02-23-2006 02:52 AM

  • Shared Variable Engine clock is consistently inconsistent

    From the annals of the weird:
    I noticed a while back that the DSM displays a different time than my system clock when I manually change a NSV value. I didn't think much of this, but then I noticed that it is not just wrong but inconsistently wrong. Here's the time difference, in seconds, between the system clock and the SVE timestamp for a dozen NSV value changes [the SVE clock always lags behind]:
    35, 14, 1, 18, 29, 2, 21, 24, 14, 17, 29, 20
    I checked these numbers in two different ways: (1) with the "Time stamp" event property node with NSV events using the DSC module and (2) manually changing values with the DSM and comparing to the displayed Windows time.
    What's the deal? The timestamp is completely useless to me with a seemingly random offset from the system time; it's by far the best way to deal with this little bit of unfortunate SV event handling behavior. Filtering event timestamps against system time is fairly standard procedure and I can't see it being useful with this going on.
    This should be trivial to reproduce--does anybody else see this? If so, is there an explaination--or better, a fix?
    [I should note that I have seen this but I'm running Intel core 2 duo, not an AMD multicore. I'm using LV and DSC 2010 SP1]

    You may have to set up the Time Synchronization Services on the computer with the DSM running. 
    In LabVIEW Help, look for Shared Variable Engine Page (Options Dialog Box)
    In DSM Help, look for Shared Variable Engine Time Server Configuration Box
    I don't know if both are necessary but I made all the computers on my system point at the same time server. The time server is configured as an Authoritative Time Server under Windows. It is in turn slaved to our DSN server which follows a Public NTP server. 
    JohnCS 

  • Shared Variable VI development on machine other than server

    I'm about to do my first shared variable code, I read the white paper
    http://www.ni.com/white-paper/4679/en
    Something that isn't immediately clear to me is the expected work flow in actually creating ALL the VIs using the shared variables.  I tried creating the project and the variable as per instructions, easy.  But I'm going to have one of those VIs running as the server of the data and one as the client.  Would these be two seperate project files with the same variable name and type?  One project file with seperate builds for server and client executables?
    Actually, SV might not even be the best way to do what I need.
    I have a PXIe machine with a slot 0 controller that has a mux (a pxi-2503) and dmm (pxi-4072) for getting measurements from multiple channels.  Rather than calling via VI server every time I want to grab a measurement I'd rather have an application running waiting on commands.  I was thinking of creating a crude command/acknowledge data avail/acknowledge scheme to synchronize the PXI slot 0 with the client that will be requesting the data, but I can imagine there is probably a more suitable framework that someone else has no doubt tackled?
    I just need to guarantee that the rack takes the measurement when I want it to (ie, after some other action I've triggered the system to perform) and that the data I get back from it is identifiable.
    Ideally, I'd have a MXI controller and this gets really easy but I won't be able to get ahold of one for months if at all so I'm going this route for now.

    Hi Marcus,
    When I drag a shared variable from the project window into the block diagram and then left click it and go to browse, I'm only presented with variables on my local machine to choose from.  If I switch into programmatic access and then go to browse I'm presented with a nice list and am able to browse to the remote shared variables and select it for my constant/control.  This works fine and I'll remember to do this from now on, I just wonder why the two different behaviors.
    I have this working quite well provided I go ahead and start the VI running either with a built exe or through the vi.  As these instruments are going to ultimately be sitting in a headless (no monitor/mouse/keyboard) PXI with slot 0 rack, I am now trying to figure out how to either start these VIs running remotely.  I thought I'd just be able to drop the .exe into a windows scheduled task and have it run on start up.  This works fine but my client VI doesn't communicate.  If I go ahead and log in to the machine I can see the exe running in the Task Manager.  If I kill that exe and start a new one then I'm able to communicate with the VI though with some initially odd behavior, almost as if when I was running it on the client the SVE had changed the states of the variables locally and then when the new process was started it latched those states and causes me to have race-like conditions.  If I then kill that exe and start another one everything is in its expected "default" state and I don't have race like conditions or get into unexpected states.  I can probably add some code on the client side to avoid this weird behavior but I'd rather understand why things aren't working.  My guess is the SVE and other NI processes on the headless box aren't starting properly until I actually log in?

  • Does OPC UA Shared Variable Server support Alarm&Event and historical access?

    OPC UA Shared Variable Server is a sample code and resides at https://decibel.ni.com/content/docs/DOC-25602
    It seems to support DSC <-> OPC-UA tag synchronization.
    But does it support alarm&event and historical access?
    I tried to open it with LabVIEW 2012, but lots of VIs were missing in the code, and I am not familiar with DSC and OPC-UA.

    Hi iCat,
    From your post on the example itself, a colleague of mine responded with: "This uses the OPC UA server included in DSC 2011 SP1 which does not include direct support for Alarms and Events. However you could use this idea to synchronize to shared variables on a Windows host which could have those abilities enabled."
    So it looks like it doesn't directly do this.
    Matt S.
    Industrial Communications Product Support Engineer
    National Instruments

  • I am trying to connect Dashboard shared variables to a server on a different subnet. Any ideas?

    My goal is to control a device that is connected to our wired network using an Android tablet via Dashboard.  I have created a vi with shared variables that controls the device as expected when it runs on a computer that is connected to the same wired network.  The problem is that my Android tablet running the Dashboard app cannot connect to the shared variables on the PC running the vi on the wired network.
    Our wireless network is on a separate subnet from our wired network.  I am able to ping my Android tablet from the PC on the wired network but when I try to connect a variable in Dashboard, the PC running the SVE cannot be found.  I tried listing it in the alternative server settings window and it still did not work.  The only way I have been able to get around this is to run the vi which launches the server on a laptop that is connected to the wireless network and the wired network at the same time.  My tablet can then find the server and my VI can connect to the instrument that is connected to the wired network.  The laptop is somehow acting as a bridge between the subnets.  I need to find a way for the Dashboard app to connect directly to the PC on the wired network.  My PC IP address is 192.168.0.105.  My Android IP address is 192.168.10.93.

    Data Dashboard doesn't care about subnets, but it has to be able to access the server using the right ports. There is probably a firewall blocking the shared variable ports. This document explains how to configure a firewall to allow shared variables to be accessed. Your challenge will probably be to figure out where the firewall is and how to configure it.
    It is also possible that the router that your Android device is connected to doesn't know how to route to the other network. Again, that is an issue with your router that you need to resolve.

  • Performanc​e of Modbus using DSC Shared Variables

       I'm fairly new at using Modbus with LabVIEW.  Out of the roughly dozen tools and API's that can be used, for one project I'm working on I decided to try using Shared Variables aliased to Modbus registers in the project, which is a DSC tool.  It seemed like a clever way to go.  I've used Shared Variables in the past, though, and am aware of some of the issues surrounding them, especially when the number of them begins to increase.  I'll only have about 120 variables, so I don't think it will be too bad, but I'm beginning to be a bit concerned...
       The way I started doing this was to create a new shared variable for every data point.  What I've noticed since then is that there is a mechanism for addressing multiple registers at once using an array of values.  (Unfortunately, even if I wanted to use the array method, I probably couldn't.  The Modbus points I am interfacing to are for a custom device, and the programmer didn't bother using consecutive registers...)  But in any case, I was wondering what the performance issues might be surrounding this API.
        I'm guessing that:
    1) All the caveates of shared variables apply.  These really are shared variables, it's only that DSC taught the SV Engine how to go read them.  Is that right?
       And I'm wondering:
    2) Is there any performance improvement for reading an array of consecutive variables rather than reading each variable individually?
    3) Are there any performance issues above what shared variables normally have, when using Modbus specifically?  (E.g. how often can you read a few hundred Modbus points from the same device?)
    Thanks,
        DaveT
    David Thomson Original Code Consulting
    www.originalcode.com
    National Instruments Alliance Program Member
    Certified LabVIEW Architect
    There are 10 kinds of people: those who understand binary, and those who don't.
    Solved!
    Go to Solution.

    Anna,
        Thanks so much for the reply.  That helps a lot.
        I am still wondering about one thing, though.  According to the documentation, the "A" prefix in a Modbus DSC address means that it will return an array of data, whereas something like the F prefix is for a single precision float.  When I create a channel, I pick the F300001 option, and the address that is returned is a range:  F300001 - F365534.  The range would imply that a series of values will be returned, e.g. an array.  I always just delete the range and enter a single address.  Is that the intention?  Does it return the range just so you know the range of allowed addresses?
       OK, I'm actually wondering two things.  Is there a reason why the DSC addresses start with 1, e.g. F300001, instead of 0, like F300000?  For the old Modbus API from LV7, one of the devices we have that uses that API has a register at 0.  How would that be handled in DSC?
    Thanks,
        Dave
    David Thomson Original Code Consulting
    www.originalcode.com
    National Instruments Alliance Program Member
    Certified LabVIEW Architect
    There are 10 kinds of people: those who understand binary, and those who don't.

  • Issue with use of shared variables in Crystal Reports 2008 Offline Viewer

    Hi,
    I have a report that contains a number of sub-reports which include drill-down functionality. The report returns data relating to an individual team with the user being able to view top level summary information in each area from the parent report and then drill into the sub-reports to view see more detail. The data returned by the sub-reports is filtered, using sub-report links, based on the team code parameter value given by the user. This parameter field resides in the main report.
    One of the values returned by the main report is the team name. This is passed to each sub-report using a shared variable and each sub-report displays this team name as part of a heading.
    This all works fine in Crystal Reports 2008, but when a report, containing data, is opened using Crystal 2008 Offline Viewer there is a problem with the shared variable. The value is displayed correctly when the user initially drills into the sub-report. However, when the user begins to drill into grouped data within the sub-report the value passed to the sub-report using the shared variable disappears. 
    How can I ensure that, when a report is viewed using Crystal Offline Viewer 2008, the value within the shared variable is not lost when users drill into grouped data within sub-reports
    Thanks
    Stuart

    Please re-post if this is still an issue or purchase a case and have a dedicated support engineer work with you directly:
    http://store.businessobjects.com/store/bobjamer/DisplayProductByTypePage&parentCategoryID=&categoryID=11522300?resid=-Z5tUwoHAiwAAA8@NLgAAAAS&rests=1254701640551

  • Why should you explicitly open and close shared variable connections?

    I'm looking into switching over from the old Datasocket API to the new Shared Variable API for programmatic access to shared variables, and I noticed that LV doesn't seem to have any problems executing Shared Variable Reads & Writes without first opening the connection explicitly. That is, I can just drop in a shared varaible Read VI, wire a constant to the refnum input, and it will work. I'm wondering, then, what benefits are offered by explicitly opening the conenction ahead of time...?
    I guess I could see some cases where you want to open all necessary connections in an initialization state of a top-level state machine, particularly if you want to use the "Open & Verify Connection"---so you could jump straight to an error case if any connections fail. But other than that, why else might one want to explicitly open the connections.
    And, along those lines, are there any problems with implicitly opening the connections? One reason why I am hesitant to open them explicitly is because for one of our applications, we need to be able to dynamically switch from one variable to another at runtime. It would be nice to just switch the variable refnum (wired to the input of the Read function), without having to manually close out the old connection and open a new one. A quick prototype of this seems to work. But am I shooting myself in the foot by doing so?
    Thanks in advance.

    I'd expect there's a very small number of people at NI that would know the answer to the detail you're asking for.  But, let's try to extrapolate from this rather old post to see if we can understand what they're forming their impression on.
    The shared variable has to have some sort of reference going on in the background.  It looks like they're calling this a connection.  It's how LabVIEW knows where to find this variable on the network.  We can also see this reference certainly exists if we're opening/closing the reference in the explicit method.  You see the connection as just a string referencing the variable by URL.  This "reference" has to be stored somewhere.  No matter how we're looking at this, we're aware there's a reference of some sort stored. 
    Now, we'd want to look at what would cause this reference to go away.  If you open/close explicitly, it's easy to see it goes away at the close.  If it's implicit, when would it make sense to close it out?  The VI can't be expected to guess where it's done being referenced and close it out.  This puts us into a situation where the soonest it could close is when the VI ends.  From my experience, references tend to be wiped when you close out LabVIEW.  It's this kind of idea that makes the FGV possible.  I wouldn't be surprised by Morgan's claim here.
    If we look at scalability, you're talking about two different topics.  You're talking about adding an extra open, close, read, etc rather than just a few wires.  That certainly would look a mess.  In terms of the dynamic swap that was being discussed, we wouldn't be adding all of those.  The concern would be if enough connections were opened it'd start to behave similar to a memory leak.  This could be something that works with a smaller number of variables.  If you continue to scale, it becomes problematic.  This is why they suggest it's not scalable. 
    To your questions:
    Does LV allocate some kind of session in memory using that string as a lookup?
    It would HAVE to allocate some memory to hold that string.  Otherwise, it'd be pointless to even have the reference. 
    Does it reuse that session if other parts of the application reference the same variable, or does it create a unique session for each referencing call to "Read Variable.vi"?
    I would expect this to be "it depends."  With the implicit method, I would expect it to open a new reference in each point it isn't wired.  This is similar to int x,y = 5;  x and y share the same value but are their own unique memory location.  If you wire the reference to the other points, it should use the same reference.  This would make more sense to me than the program seeking out any other potential usage of the variable in the application to see if there's already a reference open.  I could be wrong, though.
    And what resources does this "connection" actually represent?
    At best, this is just the string.  At worst, it's the string and the TCP socket.  I'd lean towards the first.  Opening and closing sockets should be relatively easy in most applications.  But, it also wouldn't surprise me if it holds the socket.
    I'm sure others have a better understanding than I do.  But, that's what I'd expect for anything you've asked.

  • Is there a way to reset the shared variable engine?

    I would like to be able to reset the SVE in a manner that is equivalent to what occurs during a hardware reset.
    My motivation for doing so is as follows:
    I have an cRIO app with lots of IOV's and NSV's that operate via the SV API and also with plenty of static nodes.  I am finding
    that on first run, from the DE, my CPU%=~55%.  On all subsequent
    runs my CPU%=~65%.  If I do a hardware reset or redeploy one particular
    NSV library then
    my cpu usage will return to ~ 55%.  I have tried isolating the area of code that accounts for this and have found that
    the problem centers around my initialization of one library of NSV's
    where I set its init value via the SV API.  The NSV references
    are all closed after writing without error.  So I am wondering if it
    is possible that the NSV ref's are not actually closing or possibly
    the setting of the inital value has some effect on the SVE so that subsequent runs get bogged down.
    Anybody have any ideas?

    Hello,
    If you redeploy your library, does that bring your CPU usage back down?  perhaps you can use that as a suitable workaround?  How exactly are you setting the initial value of your shared variables?
    Tejinder Gill
    National Instruments
    Applications Engineer
    Visit ni.com/gettingstarted for step-by-step help in setting up your system.

  • Are clusters or individual elements better for shared variables?

    So...  I have some RT code that is being updated, and pulled out of the Stone Ages of LabVIEW.  It was originally written for an old FieldPoint controller operating in "headless" mode, and used the "publish" and datasocket methods for communications and external control.  I had to get clever way back then, and put together a parsing/unparsing system for strings to send sets of data back and forth between the controller and any HMI or other computer attached.
    Now, I'm completely rewriting the code for a cRIO system, and doing my best to leverage all of the strengths of the latest LabVIEW versions.  I have already done an intermediate stage, where I converted from the publish/datasocket method to using network shared variables for my strings, so I could keep some of the original control and calculation logic.  Now, however, I'm going back to the drawing board for most of the program, with only some of the proven logic being held over into the new version.  And, as I'm putting together the data structures I need for both internal control and external communication, I'm in a bit of a quandary...
    I have come upon a data structure dilemma:  should I use individual shared variables for my data, or assemble associated data into clusters?  My original program had a string (essentially a flattened cluster) for each sensor in use (up to 4), one for the system parameters and states, and one for the control parameters and states.  There was a certain advantage to keeping the data compartmentalized like that, it kept things organized and forced me to avoid too many random references of each data point.  And it kept the number of communications channels limited to just a handful.  Mimicking this structure with cluster shared variables would be easy.  But, I'm not sure it's the best or most network-efficient method.
    I know the bundling/unbundling will add some processor time in my code, that is not new to me (it will still be much faster than my old parsing routines).  But, if I have individual data points being thrown around, I can access them easily from things like Data Dashboard (which is great, but far too limited to be able to grab items in clusters and such).  Having all of my data points individually available would make my project messier, but open up easier access.  It would also dramatically increase the number of data points being thrown around on the network at any one moment.  For reference, I would probably have a maximum of 100 data points at one time, made up of a combination of integers, floats, booleans, integer arrays, boolean arrays.  Or I would have a maximum of 8 clusters that would contain those data points.
    Any suggestions on which way I should lean?  Are there any advantages/disadvantages between shared clusters like the ones I need vs. the number of individual shared variables I would need using the alternative methods?  Network traffic and efficiency are always a concern, particularly since this is a "headless" cRIO in a control situation that must maintain a fast scan rate...
    Thanks for any help.  I'm so stuck on this fence, and I can't figure out which side to fall off!
    Solved!
    Go to Solution.

    Thanks Tim, that is a great source that I somehow missed in my hunt for information regarding my dilemna...
    I have to wonder though, does that 25 number also include the I/O points on your cRIO?  Anyone know that particular?  Most of the I/O points are network shared by default during initial configuration, and you could very quickly exceed 25 variables on an 8 slot rack (such as the one I use, a 9074).  Now I'm a bit worried that I'm overusing the variable engine, even before the communications clusters get figured in...

  • Print-time charting with shared variables on a report without groups...

    hello all,
    I have an interesting conundrum; I am working on a report (Crystal XI) with no groups to it, just several subreports. Presently the report is run weekly and sent to the manager of one of our departments.
    The report itself showcases all areas of the department with total tasks, longest outstanding task, average days outstanding, MTD tasks completed, and YTD tasks completed. Due to the variety of tables the data pulls from, I have it set up as subreports that simply display the data.
    All total, there are 20 different shared variables that have been obtained from 10 different subreports. I have the shared variables set as the running totals from the subreports (hence, all are print time). Since the running totals and all the subreports are time based and are not actually linked to ANYTHING on the main report, I am struggling with how to set up the formulas described in the white paper, "Charting on Print Time Formulas".
    The setting up of the two formulas ({@onchngof} and {@showval}) will be different for my situation, as all of the subreports run off of date information relative to when the report is ran. I've got all of the subreports that the shared variables originate in early in the report; but where to from here?
    Would I set up maybe a date grouping or some other non-essential consistent grouping to make it work? The way this report is, it really doesn't need grouping, because the main report is just a display agent for the subreports...
    As always, any help is greatly appreciated!

    Let me ask couple of questions before trying to resolve this.
    1. The chart you are trying to built is placed in which section and is it on Main report or sub-report of its own. This is needed because if you are trying to access shared variables values in Main report, the section should be below the sub-report placed sections.
    2. Try pacing few test formulas in Main report and make sure the correct values are being pulled in on Main report.
    If you are successfully pulling the variable values on the report, try creating a simple chart in report footer with the values you have pulled and see if its taking you somewhere...
    Would need more information on how those variables are being accessed form sub to main or sub to other sub for example are you making an array of those variables and splitting or bringing it in as separate...

  • How do I setup shared variables between executables created in sepparate projects

    Hello,
    I have several sepparate projects with their own respective executable files and I would like to be able for these executable files to all share the same variable (one program controls the value of the variable, while the others read from it).
    I got this setup to work on my personal computer (by being able to access variable manager, etc), but I need to deploy these executables on different computers that don't have the labview development program. What steps do I need to do in order for me to be able to put these executables on any computer (I'm assuming I need to setup a path for the shared variable that is always in the same folder, etc)
    Thanks
    Vlad
    Solved!
    Go to Solution.

    Hi Vlad,
    I think this article may answer some of your questions regarding shared variables in deployed applications.
    http://zone.ni.com/devzone/cda/tut/p/id/9900
    It sounds like you already have your executables built, but this article may answer some questions about deploying them to other machines.
    http://zone.ni.com/devzone/cda/tut/p/id/3303
    Jeff S.
    National Instruments

  • How to use shared variables to address multiple Watlow controller​s on the same COM port

    Hello,
    I am trying to use LabVIEW 2010 to control 4 Watlow temperature controllers on one COM port. 3 are Model 96 and 1 is an EZ zone controller. Each controller has a unique modbus address, and I am trying to read from and write to individual registers (such as closed loop setpoint) using shared variables. I am getting return data when reading (although the data appears to be invalid), but am unable to change the value in the register by writing. How can I be sure that the Modbus server is sending commands to the correct controller?
    Chuck
    Solved!
    Go to Solution.

    Peter,
    Thanks for the reply. I have actually solved that problem. I realized that the Modbus server address has to be the same as the controller's Modbus address.
    I have, however, run into another problem. Perhaps you could help me with that. I have a system with 4 Watlow controllers, 3 are series 96 controllers, one is PID only and 2 are ramping. The 4th controller is an EZ zone. I am using RS485 for communications and the controllers are all wired in parallel for communications and power.
    I have set up 2 Modbus servers for 2 of the controllers.
    This is the first I have ever worked with Modbus based communications. I have successfully programmed using the Modbus read/write VIs, and am wanting to move to shared variables. My questions right now revolve around addressing, Modbus I/O servers and COM ports. Specifically, at this point, I know the addresses need to match up between the server and the slave device (Watlow controller in my case), how many servers can I create and use on one COM port? If the number is limited, is there a way I can specify an address that I want the server to talk to? Will the broadcast mode work to request data values from the controllers?
    I'd appreciate any information you can help me with, or if you could point me to some sort of concise 'How-To' for Modbus communication.
    Thanks.
    Chuck

  • How to add a new Shared Variable programmatically to an existing and deployed library?

    Hi there!
    I am trying to accomplish this on both LabVIEW 8.6 and LabVIEW 2010 and seems like it's not any different in this situation.
    My case: A project has a library with 4 Shared Variables (SVs). The library and the variables are deployed (visible in Distributed System Manager 8.6/2010). I want to add 2 more variables into this library. It is possible to do this manually from Project Explorer window's options menu. But while running an application it has to be done programmatically. Can I provide the library reference to the one currently existing without creating a new one?
    "Create Or Add Library To Project" function in the Datalogging and Supervisory Control (DSC) toolkit does not help in this case. That function, as the name suggests, just tries to create a new library in the project.
    Two possible methods:
    The function "Add Shared Variable To Library" (DSC>EngineControl>Libraries & Processes) needs a library reference, which could be provided via "CreateOrAddLibraryToProject" function, but this function tries to create a new library, and if I provide the path of the existing library it throws an exception that the library already exists in the project (yes, as I wrote above, I need to add new variables to an existing and deployed library).
    OR
    The function "Create Shared Variable" (DSC>EngineControl>Variables & I/O Servers) will add Shared Variable in a process, and not physically in a library file, and the problem (limitation) with this approach is that it doesn't allow to add complex data type Shared Variables (for example in LabVIEW 8.6 it has only 4 datatype options in input parameter, and even in LV2010 it does not have "Image" datatype that I need).
    The scond method is my preferred method as it allows to work on Online Shared Variables and doesn't create them physically in libraries (and this is good as the variables' scope remains only till the Variable Engine is running). But it doesn't support advanced data types, and the first method is powerful in terms that it supports to virtually any datatype, it just seems tricky to get that reference to the library.
    Any tips?
    Thanks ahead!
    Vaibhav

       <<<<>>>>   
    As the above two images show, while a library does not exist, it is easy to use the "CreateOrAddLibraryToProject.vi" which will add a new library to the project (if it doesn't exist on file system, a new library will be created) and that way, using the reference (the green wire going out from the function and the Case Structure, can be used to add Shared Variables to the library. The problem was what to do when a library already exists in the project, how to add more variables to it. I was looking for a way to get a library reference, and somehow I could not see it inside a Project's property (VI Server functions). Hence I posted the question. And upon continuing my search, I found it on the Application's property list.
    I hope it was useful for someone else as well. And thanks for the replies. Please share a better idea if you have.
    Vaibhav

Maybe you are looking for

  • How can I connect a MacBook Air (new) to a Sony Bravia TV

    How can I connect a MacBook Air (new) to a Sony Bravia TV

  • How come this program compiles?

    class Base      Base()           int i = 100;           System.out.println(i); public class Pri extends Base      static int i = 200;      public static void main(String[] args)           System.out.println(i);           Pri p = new Pri(); i get very

  • Upgrade new mac air to Lion

    how do i upgrade my OS to lion? its a new mac air, purchased yday. i am told i would be able to do it from apple website, free of charge.

  • Flash CS6 no Fireworks import dialog box?

    In Flash CS6, when I try to import a Fireworks PNG I never see a dialog box asking whether I want to import it as a flattened image or as an editable Fireworks PNG file. It simply imports the PNG as a flattened image. It doesn't seem to work as it di

  • Adding Sales Order

    Hi, I need to add sales orders through my add-on. I could add the sales orders. But, when I'm adding lines to the sales order, I'm getting the following issue: There is a difference between the document total and its components.  [ORDR.DocTotal][line