Simulink to LabVIEW automatic conversion

I used the Tools>>Control Design and Simulation>>Simulation Model Converter to convert a Simulink file (.mdl) to a .vi (multiple files). The problem is that the converted files have a lot of errors and therefore  are not executable. The most frequent error is "You have two terminals of different types. the type of the source is cluster of 2 elements. The type of the sink is 1-D array of double [64 bit real (15 digit precision)] " How to I resolve this error? Is there a difference between Bus Creator/Bus Selector and Bundle/Unbundle in Simulink and LabVIEW respectively? I attach a sample VI. Thanks.
Attachments:
Water Pump.vi ‏13 KB

Hello AAR,
I cannot speak as much to the exact functionality of the Bus Creater/Bus Selector, but I will see if I can describe the bundle/unbundle to help clear up any confusion.
The Bundle function creates a cluster in LabVIEW which can be a group of like or unlike data.  This cluster can be passed around the diagram and then the Unbundle or Unbundle by Name functions can be used to pass out a particular value in the cluster.
I am not sure what your original model was doing, but it is easy to see why the VI you attached is broken.  You can resolve the broken wires in some different ways, and it depends on your intention with your original model.
The attached file builds several scalars and an array into a 1-D array.  This array is then Bundled with a second array.  The cluster output of this bundle function is then being passed to an indicator called Water and a Global Variable called Inlet_water.  The datatype of both Water and Inlet_water is an array of doubles.  In LabVIEW the cluster datatype and array datatype or not interchangable.  I am not sure how these arrays are used in the rest of the model, but here is where your options come in.
You could replace the Bundle with a Build Array(concatenate the inputs to make one 1-D array rather than a 2-D array).  Then, wherever you need access to specific elements of the array you can use the Index Array function.  For this modification you will need to know the index of the element you are interested in when using the Index Array.  Either that or convert your global variable and indicator to be clusters.  I think the first modification would probably be the simpler modification, but again it is dependent on how you intend to use the data in the rest of your model.
I hope this helps, please post back if you have further questions about this.
Regards,
Angela M
Product Support Engineer

Similar Messages

  • In Pages 5, Maverick, How do I stop automatic conversation of URLs to hyperlinks and seeing them underlined

    There used to be a preference setting in Pages.  Now it seems gone in Pages 5.   So how do I stop automatic conversation of URLs to hyperlinks and seeing them underlined in text.  Sometimes I want it, but not always.

    The preference setting to turn off links is gone. When you enter content that triggers link detection, a link character style gets applied. Right-click on the link, choose Edit Link from the menu, and then Remove.
    To prevent Pages from automatically detecting links, visit Edit > Substitutions > and deselect Smart Links.

  • I have taken off/turned off iCloud on my mac mini but when I write an email   and use contacts it will convert a non iCloud email to and iCloud email automatically.  I really don't want this. Any way to stop this automatic conversion?

    I have taken off/turned off iCloud on my mac mini (OS 10.8) but when I send an email and use contacts , it will convert the non - iCloud email to an iCloud email automatically.  Anyway to stop this automatic conversation?    

    Robert...
    the iCloud webserver wont accept my password for a .mac login, nor will it allow me to change it
    See if you can change your password >  Apple - My Apple ID
    If that doesn't help, launch iTunes on your computer.
    From the iTunes menu bar click iTunes / Preferences then select the Advanced tab.
    Click: Reset warnings and Reset cache
    Click OK.
    Restart your computer.
    If that that doesn't help...
    Moreover, when I try to go into my .mac account on the web,
    Delete all apple cookies and empty your browser cache.
    See if  you can access your account at iCloud.com

  • Automatic conversion

    Hi,
    I would like to now if SAP KM can handle automatic conversion to a neutral documents formats (like PDF).
    TREX converts all the documents to HTML but this result is not available as a document in the portal (only when you use the HTML version link in the search results). I would like this result (HTML, PDF or some other format) as a new document...
    Who can help me out here?
    Thanks!

    Hello Simon,
    as far as I know, there's no mechanism in KM to convert documents automatically.
    But there is a business package called "Business Package for Web Editing"
    (find it <a href="https://www.sdn.sap.com/irj/sdn/developerareas/contentportfolio">here</a> by searching for 'web editing').
    This package contains a KM Service that convertes office documents to HTML-Files automatically using the "save as html"-functionality of MS Office. The result is quite excellent.
    Unfortunately this package is developed by SAP Consulting and they charge a fee for it.
    Please reward points, if this helped to solve your problem,
    Carsten

  • Automatic conversion of planned orders

    Hi PP Gurus,
    I have a requirement to convert planned orders to production orders automatically. I believe SAP standard does not offer this functionality.
    The possible solution seems to be writing new program which could be a copy of C041 transaction code.
    Did someone ever worked on this functionality?
    Request to share your experience and possibilities on this - Thanks
    Regards
    Seshu

    Dear Seshu,
    In my understanding there is no T Code for making the conversion of planned order into a production order as an automatic
    process.
    But you can use the T code CO41 for converting a list of planned order's into production orders.
    In many cases the planned order is only a proposal and only after converting it into a production order and releasing it then the
    exact shop floor activities starts like Good's issue.This activity is done by a production scheduler.So in case if you develop a
    program to convert automatically,then reservation gets generated for all the production orders, which is not recommended.
    Also check this link,
    http://www.sap-img.com/production/automatic-conversion-to-production-orders.htm
    Check and revert back.
    Regards
    Mangalraj.S
    Edited by: Mangalraj.S on Aug 11, 2009 10:04 PM

  • Automatic conversions...A Bug? or just a feature(How to turn it off?)

    I Using TS 3.0(.0.12373) I seem to have stubbled over a annoying 'feature' which I can't turn off...Any one got ant ideas.......
    Every sequence file I load(eg from the \examples\) when When loaded the '*' appears next to the file name indicating a change has happend. When closing the file TS asked "......file modified due to automatic conversions TestStand performed when loading file".
    The only change that happened to the .seq file is a change to the Path, timestamps, and Version(From 3.0.0.12373 in the original to 3.0.0.12374 in the Updated one) at certain points in the file (found using a examine differences program ExamDiff.exe) examples below.
    Any ideas how this feature is switched on,
    and more importantly how to switch it off?
    Cheers
    Attachments:
    rtebeep.seq ‏18 KB
    rtebeep_new.seq ‏18 KB

    Wojtek -
    It appears that somehow you have edited an NI type and incremented the version number. Your debug work was correct, so looking at the sequence file you will notice that the following sections have a changed version number:
    [Action]
    %VERSION = "3.0.0.12374"
    [Error]
    %VERSION = "3.0.0.12374"
    Basically TestStand assumes that the newly edited NI type superceeds the one the TestStand finds in the sequence file. For most NI types, the default copy is stored in the type palette files and these probably have the 3.0.0.12374 version. Depending on which NI type was edited, a copy of the newly edited type might also be in the INI files that TestStand uses in the Cfg directory.
    In TestStand 2.x if a user attempted to
    edit an NI type instead of creating your own copy of the type, the sequence editor would warn them and suggest not editing the NI type. In TestStand 3.0, we wanted to be more strict and not allow editing of NI types at all, but the code did not work properly when released and instead it allows anyone to edit NI types without a warning. TestStand 3.1 now propertly prevents the editing of NI types.
    What I recommend is to search all INI files under TestStand and all your sequence files for the '%VERSION = "3.0.0.12374"' text and hand edit them to replace this text with '%VERSION = "3.0.0.12373"'. This should address the issue for you.
    If you have sent sequence files to others, and you do not want them to see the automatic conversion issue, their files should also be hand edited. Sorry for the inconvenience.
    Sincerely,
    Scott Richardson (NI)
    Scott Richardson
    National Instruments

  • SNMP service automatic conversion

    Does Windows SNMP service do automatic conversion from SNMPv2 to SNMPv1 ?
    John

    Hi,
    If I doesn’t misunderstand, you are talking about the SNMP traps translation.
     If so please refer the following KB:
    When the Microsoft WinSNMP implementation receives traps from an entity operating under the SNMPv1 framework, it translates the traps to the SNMPv2C format. Therefore, when
    SnmpRecvMsg delivers a trap it is always in the SNMPv2C format. RFC 1908, "Coexistence between Version 1 and Version 2 of the Internet-standard Network Management Framework," specifies the rules for translating from the SNMPv1 to the SNMPv2C trap
    format.
    The related KB:
    Translating Traps from SNMPv1 to SNMPv2C
    http://msdn.microsoft.com/en-us/library/windows/desktop/aa379177(v=vs.85).aspx
    Hope this helps.

  • Matlab, simulink et labview

    Bonjour à tous,
    Je me suis renseigné sur le sujet, et j'aimerai savoir si j'ai bien compris.
    On peut incorporer du code matlab dans labview , via la boite script "matlab" du diagramme, pour utiliser simulink avec labview, il faut creer une dll à partir du code généré sous simulink.
    Est ce que j'ai bon, ou peut on incorporer aussi du code sous simulink dans Labview, via une boite spéciale.
    Merci pour vos réponses

    Bonjour,
    Merci d’être venu sur le forum de National Instruments.
    A priori vous avez bien compris comment intégrer du code Mathlab dans LabVIEW. Pour ce qui est de Simulink il faut effectivement appeler un DLL créé sous Simulink. Ce lien vous permettra de savoir comment faire.
    Benjamin R.
    R&D Software Development Manager
    http://www.fluigent.com/

  • Simulink and labview syncroniza​tion

    I have a simulink model that has inputs controlled by Labview and outputs displayed in Labview. On my desktop computers the simulink and labview are running in sync, their times are always together. When I load the programs onto my two laptops, the simulink model is running 2-10 times faster than the Labview program, and when I change controls in Labview, they don't take effect in simulink unless I change the control MANY times. I think this lack of communication between labview and simulink on my laptops is happening because they are out of sync, but not sure, any suggestions?

    Hello,
    You mentioned that the program works fine when you are using a desktop, is simulink and LabVIEW running together on the same desktop or do you have them networked together? By default simulink communicates through port 6011 using TCP/IP. It possible that for some reason that the communication is inhibited by some process on your laptop that is also using that port and causing only some of the simulink data to get through. It is possible to change ports when starting simulink if you know that a port is blocked or being used by another process. When starting the SIT server, type NiMatlabServer ('start',xxxx) You can choose any port that you want, but many times firewalls will close ports. Each firewall is different so you will have to look into what ports that you have available for TCP/IP communication with the SIT server. Have a great day.
    Regards,
    Danny G.
    Applications Engineer
    National Instruments

  • How to disable the automatic conversion from JPEG to TIFF?

    I am using Keynote '09 and Safari 4 on OS X 10.6.8, and I often want to drag and drop a JPEG image from Safari to my slides. I would like to keep the image format as is, but Keynote automatically converts the image format from JPEG to TIFF, so the .key file size becomes large.
    Does anyone know how to disable this automatic conversion? Any idea? I know that I can use the original format if I save the JPEG image at a temporary location, such as ~/Desktop. But I would prefer simpler way. Drag and drop is the best.

    Indeed, having the same problem here.  A simple PPT file that was 1 MB ballons often to more than 10 x the size as a KEY file.  If you rename to zip and open, one notices lots of completely useless "PLACEHOLDER" and background files that occupy several MB in total, plus some small JPGs have been converted to very large PNGs.  This is truly annoying. 
    A similar lack of "file size economy" is present in all applications apple produces for the ipad/iphone.  Images I uplodaded to the photo app become very large (often 10 x bigger).  WTH apple?  Be more economical!  Even my 64 GB ipad2 is starting to feel small with your waste.

  • Schnittstellen zwichen Matlab/Simulink und Labview

    Hallo Leute,
    ich habe ein Diplomthema wo ich muss ein Fpga I/O (muss nicht die ganze I/O sein) mit ein block in Simulink(Simulink Model) aufrufen.
    im moment kann ich die Programmierung des Fpga auf ni pxi 7813R unter labview machen und dann würde mir ein file konfiguriet.
    Um ein Simulink model mit Labview zu verbinden braucht man SIT .
    Jetzt kommt die Frage :die I/O des Model kann ich nur unter labview definieren, nun musse ich jetzt in meiner Diplomaufgabe in Matlab/Simulink in einer Blockset definieren .
    Weiss jemand irgendein Information darüber, ich weiss noch nicht wie kann ich das realisieren. bitte sagen sie mir jede Information die mir helfen kann . ich wäre sehr dankbar 
    houssa

    Hi,
    ich benötige leider dringend und kurzfristig Hilfe.
    Ich hab eine 10-15 Seitige Hausarbeit  geschrieben bzw. bin noch dabei, es geht um die  Kopplung von Simulink mit LabVIEW zu schreiben.
    Die Note der Hausarbeit, wird meine Zeugnisnote für dieses Fach sein.
    Daher suche ich jemanden der sich das durchlesen kann und von der Materie versteht.
    Natürlich gegen Zahlung
    Bitte um schnelle Rückmeldung.
    Lieben Gruß,
    Lisa

  • Automatic conversion of TDMS files to *.mat procedure in Diadem

    Hello to all,
    I have a very large set of data aquired with a PXI chassis. The data is saved in TDMS files. Each TDMS file contains data from  10 acquisition channel. I have to convert this data into Matlab readable fiels, *.mat files. Unfortnately, there are a lot of files (900GB), each file is very large (17GB), and therefore manual conversion is very long and I cannot afford to waste so much time. 
    Does anybody know if I can develop an automatic procedure in Diadem that will take a TDMS file and output 10 *.mat files?
    I have to mention that I have tried to convert the TDMS files using Matlab scripts found on Matlab Central, but with no success. I have also tried using some VIs I found on the NI Support forums, but all failed. I am left woth this third solution in Diadem that works, but takes a lot of time.
    I am open to any suggestion.
    Thank you all,
    Jean

    Hi Jean,
    Have you looked at this document: http://digital.ni.com/public.nsf/allkb/1706BA4C65A8533686256C630062DD03
    You can use this dataplugin in DIAdem, to import/export files from/to MATlab: http://zone.ni.com/devzone/cda/epd/p/id/4178
    Let me know if you need more informations.
    Regards,
    Benoit S. - Field Sales Engineer
    Certified LabVIEW Developer
    Certified TestStand Developer
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    Été de LabVIEW 2014
    12 présentations en ligne, du 30 juin au 18 juillet

  • Simulink to labview

    Hi , 
    I want to convert my simulink model to a VI
    I have attached the .mdl file
    Please help me in the conversion
    I am not able to find the substitute for a clock function which is acting as an input as u[1]...it is a unit step signal , increasing linearly with time

    If you want to just call your model from LabVIEW you can try the Model Interface Toolkit. If you just want a clock signal as you've described it, it looks like you just need a loop running at 1 second per iteration and an indicator coming from its iteration terminal. Another option is using the tick count VIs if you want the actual time elapsed instead of just a count. I've coded both in the example below. Is this what you were looking for?
    Miles G.
    National Instruments
    Applications Engineer
    Attachments:
    Forum Clock.png ‏23 KB

  • Automatic conversion of purchase requisition to purchase orders.

    Hi
    I normally convert purchase requisition to purchase order automatically through ME59N. Now I want only firmed requisition to be converted to Purchase order when I run ME59N. Is there any way to do this.
    Other than ME59N is there any way to convert firmed purchase requisition to purchase order automatically.
    Thank you
    Regards
    Sarin Toms

    Hi There
    ME59n is the transaction generally use to convert all the PR to PO
    You can use the release startegy for the PR_PO conversion check instead of Firming indicator.
    (As per the system if anyone do changes or PR is created through MRP this ind will be set automatically,) or you can do minor development on me59n to check the Fixed Indicator enabling before convert the PR to PO
    Lets wait for other experts post on this to check whether is there any other way to do,
    Thanks
    Senthil P

  • Serial communication from simulink to labview

    hello everybody,
    i have problems with establishing serial communication from simulink(where the data is generated) to labview (version 2010).
    i tried everything but it won t work.can you please help me on this one pleaaase.
    thanks ^^
    Attachments:
    projet labview.vi ‏15 KB

    thanks so far for your replies,
    to clarify any confusion this is my system in simulink.
    the data are decimal values
    thanks again, hope i ll receive a reply from you guys soon cause i really need to progress in my project
    Attachments:
    xxx.PNG ‏20 KB
    yy.PNG ‏35 KB

Maybe you are looking for

  • Slow start-up time on iPad 4 after updating to iOS 7

    I have just updated my iPad 4 from iOS 6 to iOS 7, and realized that it took much longer to switch off and back on than it used to be (at least double the time). Anyone have the same issue? How to make the start-up time faster? Thanks.

  • Problem invoking AIR on RHEL 5.1 machine

    Hi, We have been able to successfully install AIR application .rpm on REHL 5 machine. But, it just sits there but no success in being able to open it or any .sir help files using that. Please help. -Pooja

  • Update several data simultaneously in a database

    Hello all, Who can help me on this : I am trying to update simultaneously all data returned with a simple cfoutput query, where all form tags are indexed with all the id(s) returned by the query (same serie of input/textarea/etc. for each id, but onl

  • MIGO- Number of external delivery note "LFSNR"

    Hi all, we use R/3 4.7 release. Is it possible to activate a check which permits to restrict the usage of that field in MIGO one time for each vendor preventing the possibility to double entry a Goods receipt? Your answer is appreciated Thanks in adv

  • Abstract portal component and JSP question

    Can we use htmlb components in abstractportal components. I am using isolatedhtmlcontainer in abstractportal component and it is not compiling. It works fine with Dynpage component Also one more question can we just write a JSP to get the userid of t