Serial communication from simulink to labview

hello everybody,
i have problems with establishing serial communication from simulink(where the data is generated) to labview (version 2010).
i tried everything but it won t work.can you please help me on this one pleaaase.
thanks ^^
Attachments:
projet labview.vi ‏15 KB

thanks so far for your replies,
to clarify any confusion this is my system in simulink.
the data are decimal values
thanks again, hope i ll receive a reply from you guys soon cause i really need to progress in my project
Attachments:
xxx.PNG ‏20 KB
yy.PNG ‏35 KB

Similar Messages

  • No output from Simulink to LabVIEW with Simulation Interface Toolkit (0/1)

    I'm able to send data from labview to simulink, but the labview
    display doesn't show any output from the simulink model. I've attached
    two very simple labview and simulink files which gives me this
    problem. I have the same problem when trying to implement the sinewave
    example in the manual for the toolkit as well.
    I'm using LabVIEW 7.1 Pro, Matlab 6.5 and Simulink 5.0 on WinXP pro.

    The Simulation Interface Toolkit 2.0.1 or earlier does not work with LabVIEW 7.1. There is a patch available (or available soon) from NI support that corrects this problem. THe patch is Simulation Interface Toolkit 2.0.2.

  • Fuzzy system from simulink to labview

    Hey all, hope you are well. 
    I have a developed fuzzy system in simulink, how would I go about transfering this over to labview? If anyone has any help or developed a model that can do this. Any advice is well recieved. 
    regards
    Alim Guy

    Hi Alim,
    This can be achieved using the Simulation Interface Toolkit, which can be purchased from this URL, which allows you to directly interact with models developed in Simulink. This toolkit will import the developed files into LabVIEW. In terms of researching Fuzzy Systems created within LabVIEW, if you have the Fuzzy Logic Toolkit, you can go to the NI Example Finder (LabVIEW > Help > Find Examples...) and search for the keyword 'Fuzzy' you can view Fuzzy Systems developed purely in LabVIEW. You can learn in depth about Fuzzy Logic Toolkit here to see if these tools suit your specific requirements.
    In terms of the ease of implementation, it really depends on what you're after. It's not so much what process is easiest, but what you are suits your current process of development. If you're used to developing systems in Simulink and it's the standard at your workplace, then it's probably more suitable to implement your Fuzzy System through the Simulation Interface Toolkit; there are some extra steps required when importing the data in terms of referencing the variables appropriately in LabVIEW but it's not a lot of extra work. If you're interested in developing and implementing your systems entirely from the LabVIEW environment, it will be worth using the Fuzzy Logic Toolkit.
    Regards, 
    Alex Thomas, University of Manchester School of EEE LabVIEW Ambassador (CLAD)

  • Incorporation of Fuzzy Block From Simulink into LabVIEW Through SIT

    I am working on a project where I am using Simulation Interface Toolkit. In my applciation, I am using PXI-8176 with a PXI-6070E DAQ card. I generated my model using Simulink in which there is a Fuzzy Logic Control block.
    However, when I run my application real time on my PXI 8176 machine,  for some reason, the output of the fuzzy logic block is always constant when
    it is supposed to be changing as I change the inputs to the block ( I am able to observe my hardware input). I got in touch with the Mathworks people and confirmed that the DLL file generated by the real-time workshop contains the fuzzy block and everything seems to be working well with that dll file. I was wondering if there is any additional step that I have to follow in order to make the fuzzy block work in real time in my real-time machine. Or is there something that I need to do to be able to observe the fuzzy logic outputs?
    The steps that I walked through as folows:
    1-)I went to build option and the pick nidll.tlc, as I am targeting a PXI
    machine for the real-time application.
    2-) I built my appliciation using Real-time workshop.
    3-) Then I opened  Labview program to generate a user interface for my
    simulink model using (Simulation Interface Toolkit). Then I loaded the dll
    file generated by the real-time workshop and deployed the final code into
    the PXI Real-time machine. Everything is working just fine except that
    when I probe the output of fuzzy logic control block, it always spits out
    constant values. However, the output of the fuzzy logic block is always
    constant when it is supposed to be changing as I change the inputs to the
    block.
    Thank you so much!
    Serdar

    Hi Serdar,
    Have you tried running your model in LabVIEW on your host computer?  Try simulating the hardware with controls and indicators and see if it is running correctly without the hardware.  Also does your model work correctly before using SIT to connect to it.  LabVIEW and SIT only reference the model you created.  
    Best Regards,
    Bryan H.

  • I use LabVIEW 7.1 but I have some problem when, I use LabVEW to read the data from serial communication

    I use LabVIEW 7.1 but I have some problem when, I use LabVEW to read the data from serial communication.
    I use LabVIEW to read the data from serial communication then, i open the example (.vi) from Serial Communication - Advanced Serial Write and Read  from LabVIEW Example. BUT it have some error message that : Error - 1073807202 occured  at property node in visa configure serial port (instr).vi -> advance serial write and read .vi
    this error code is undefined. no one has provide a description for this code, or you might have wired a number that is not an error code to the error code input.
    I don't know why? please help me. thank you.

    When I copy that code into "Explain Error" I get: "VISA:  (Hex 0xBFFF009E) A code library required by VISA could not be located or loaded."
    You may have a bad install of VISA or the wrong version of VISA loaded. Try re-installing VISA. You can get the latest version from the NI support site: http://digital.ni.com/softlib.nsf/webcategories/85256410006C055586256BBB002C0E91?opendocument&node=1....
    Also ensure that you are not pointing the example towards a serial port that does not exist.
    Please let us know what you find and what gets this working for you.
         Rob

  • Midlet with access to IrDA/serial communication on PDA urgently needed!

    Hi folks,
    our solution needs access to the IrDA or serial communication from within a midlet. Unfortunately this is not possible with the current MIDP implementation. The mobile we are using has additional vendor specific classes, but still IrDA fails when connecting to other mobiles or PDAs. Therefore, we are looking for a KVM on WinCE/Palm which provides access to the IrDA or serical communication channel in order to develop our application on a PDA while waiting for MIDP 2.0 to come.
    Please send me some feedback ;-)
    Cheers Harald

    Indeed the serial port access to the IR port is supported in the latest WSDD releases.

  • Problems with Serial Communication using Labview 6 and Solaris 8

    I am working on a Driver for a Temperature Controller. But I am stuck at the very basics. I am using Labview 6 and the platform is Solaris 8 on a SUN Ultra 60 Workstation. I can not get the Serial communication to work. When I am running raw (uncompiled) code it works (I can read from and write to ttya and ttyb) but once compiled I get error code 37 (device not found). I have tried the following steps to fix this with no luck.
    1) I made sure that the "serpdrv" file is in the same folder with the executable. I also make sure the serpdrv file is added as a support file when building the app.
    2) I changed from using traditional serial VI's to labview 6's new visa functions. With these "new" VI's when
    I try to initiliaze the visa device and wire a control to the "visa reference" input only 1 serial port shows up (ASRL2, missing ASRL1). I am not sure if this is part of same problem or whole new issue.
    3) I reinstalled both visa and labview 6.0.2 update hoping this would help with no luck
    4) I placed the following entry into the ".labviewrc" file
    labview.serialdevices: "/dev/ttya:/dev/ttyb"
    If anybody has had the same problem I would love to hear about it and if you have any solutions
    Jamie Shea

    Hi Jamie,
    1. Do you have NI-VISA driver installed on the machine on which you are running this executable?? If you are trying to run the executable on the same machine on which the development program has ran fine, then you can ignore this point.
    2. If you have done all the changes that are suggested by other discussions related to this topic, then try changing the Port input to Visa Serial Configure.Vi from a control to a constant and try it. In some case, I have seen this to do the trick. I think this point should solve your problem. If it does do tell me. :-))

  • Transfer functions imported from Simulink through MIT not working in Labview

    Hi,
    I am just starting to use Labview interface with Simulink using Model Interface Toolkit (MIT). I am trying to import an integrater model from simulink. The model is very simple. An input port connected to an output port through an integrator model (1/s). Here are the steps I used:
    1. Build the model in Simulink.
    2. Add the NI input-output ports to the model and place the NIVeriStandSignal Probe in the model.
    3. Generate the dll using NiVeriStand.tlc as the target file option.
    4. Import that dll into Labview using Load Model.vi. Follow the steps given in the example file for importing the input/ output ports info along with the timing info.
    5. Then use a numeric control to input value to the integrator dll and pass the output from dll to a waveform chart.
    But when I run the labview VI, the output in the chart is always zero. What could be the possible reason? Please let me know if I am making any mistake in the process?
    I have used Fixed time step with ode4 (Runge-Kutta) as the solver options in Simulink during dll generation. I am using Labview 2014 and Matlab R2014a.
    I have found the issue to occur only when I use any transfer functions or Plecs circuit with inductors or capacitors in my Simulink model. But when I use simulink model with only constant or maths functions like add, subtract etc, this process works and gives me the correct result in Labview.
    Any help would be appreciated.
    Thanks.

    Hello Sachin_Madhu,
    Can you build example programs with a solver included? Does the model work in The MathWorks, Inc. Simulink® Software without tying into LabVIEW? It is important that when you built the model you followed the four steps listed in this help file:
    http://zone.ni.com/reference/en-XX/help/374160A-01​/vsmithelp/mit_convert_model_to_dll/
    MATLAB®, Simulink®, and Real-Time Workshop® are registered trademarks of The MathWorks, Inc. Other product and company names listed are trademarks and trade names of their respective companies.
    Siana A.
    Application Engineering
    National Instruments

  • I w'd like to know if LabVIEW 6.0 Application Builder includes the daqdrv (for data acquisition) and serpdrv (for serial communication) support files by default.

    Building an application to communicate to a device by serial port

    Hi velou
    The LabVIEW 6i Application Builder no longer requires daqdrv. Regardless of your Application Builder and LabVIEW version, you must always install the appropriate driver files on the target machine. For example, if your application communicates with a DAQ board and a GPIB board, then you must install NI-DAQ and NI-488.2 on your target machine. If you are using the VISA VI's for serial communication, than you have to install NI-VISA . If you are using the "old" serial VI's, than you have to include serpdrv separately.
    Luca P.
    Regards,
    Luca

  • Hide serial number from LabVIEW startup screen.

    Is there any way to hide LabVIEW 2009 serial number from startup screen?
    Corporate version, but every visitor can see it. Bad.

    This goes along the same lines as this issue.
    I would recommend you submit an idea to not show the activation code on the startup and about screens. I agree it is sufficient to show these only in the license manager.
    I always struck me as odd to show the number on the startup screen. It is not needed there.
    In the meantime, you might want to startup LabVIEW before the visitors arrive or before you hook up the projector and start the presentation.  
    LabVIEW Champion . Do more with less code and in less time .

  • Arduino due and Labview wirelss serial communication using Xbee

    Hello.
    I am controlling a mobile robot using the Arduino due and labview
    PWM value caculated on the labview is sent to Arduino due and then Due controls the robot.
    These communicate wirelessly by xbee.
    Now, I'd like to increase the communication speed between Arduino due and Labview.
    but, when i set the value of the "Wait(ms)" function to below 10ms  in Labview, communication has unstability.
    so please let me know how increase the communication speed.
    thank you.
    -experiment image-
    https://www.youtube.com/watch?v=oZdMCdHlDhM
    - Arduino source-
    #include <string.h>
    int PWM1 = 5;
    int DIR1 = 4; //direc
    int PWM2 = 6;
    int DIR2 = 7; //dir
    float readNumber = 0;
    float In1, In2, pwm, newtime, A;
    float newposition1 = 0;
    float newposition2 = 0;
    unsigned int Aold1 = 0;
    unsigned int Bnew1 = 0;
    unsigned int Aold2 = 0;
    unsigned int Bnew2 = 0;
    volatile long encoder1Pos = 0;
    volatile long encoder2Pos = 0;
    int encoder1PinA = 8;//Encoder A pin
    int encoder1PinB = 9;//Encoder B pin
    int encoder2PinA = 11;//Encoder A pin
    int encoder2PinB = 12;//Encoder B pin
    int Direction1, Direction2;
    float pwm1_limit=255;
    float pwm2_limit=255;
    float count_old = 0;
    float power1_old, power1_old2, power1_old3, power1_old4, power1_old5;
    void setup() {
    // put your setup code here, to run once:
    pinMode(DIR1, OUTPUT);
    pinMode(DIR2, OUTPUT);
    Serial.begin(115200);
    Serial.flush();
    Serial2.begin(115200);
    Serial2.flush();
    pinMode(encoder1PinA, INPUT);
    digitalWrite(encoder1PinA, HIGH); // turn on pullup resistor
    pinMode(encoder1PinB, INPUT);
    digitalWrite(encoder1PinB, HIGH); // turn on pullup resistor
    pinMode(encoder2PinA, INPUT);
    digitalWrite(encoder2PinA, HIGH); // turn on pullup resistor
    pinMode(encoder2PinB, INPUT);
    digitalWrite(encoder2PinB, HIGH); // turn on pullup resistor
    attachInterrupt(encoder1PinA, d1EncoderA, CHANGE);
    attachInterrupt(encoder1PinB, d1EncoderB, CHANGE);
    attachInterrupt(encoder2PinA, d2EncoderA, CHANGE);
    attachInterrupt(encoder2PinB, d2EncoderB, CHANGE);
    void loop() {
    if(Serial2.available()>0){
    String first = Serial2.readStringUntil('!');//랩뷰에서 받는 2개의 값을 분리하기 위한 소스("!"앞까지 끊고, "@"앞까지 끊음 ex)123!456@을 받으면 123과 456으로 나눔)
    String second = Serial2.readStringUntil('@');//http://stackoverflow.com/questions/29504679/splitting-a-comma-separated-string-through-serial-arduino
    float x = first.toFloat();//위에서 분리된 문자를 float형으로 바꿔줌
    float y = second.toFloat();
    newposition1 = -encoder1Pos; //Encoder signal
    newposition2 = encoder2Pos; //Encoder signal
    count_old = 0;
    float power1 = x;
    float power2 = y;
    if(power1 >= 0){
    Direction1 = LOW;
    else{
    Direction1 = HIGH;
    if(power2 >= 0){
    Direction2 = HIGH;
    else {
    Direction2 = LOW;
    power1 = abs(power1);
    power2 = abs(power2);
    if(power1 > pwm1_limit){
    power1 = pwm1_limit;
    if(power2 > pwm2_limit){
    power2 = pwm2_limit;
    digitalWrite(DIR1, Direction1); //HIGH = back, LOW = forward
    digitalWrite(DIR2, Direction2); //HIGH = back, LOW = forward
    analogWrite(PWM1, power1);//PWM Speed Control
    analogWrite(PWM2, power2);//PWM Speed Control
    String strValue = String(newposition1);//숫자를 문자형으로 변환
    String Q = "!";
    String strValue2 = String(newposition2);
    String stringThree = strValue + Q + strValue2;//문자 합치기
    Serial2.println(stringThree);//Send encoder pulse to Labview
    else {//when Serial communication stop
    float count = count_old+1;
    if(count > 10000){
    newposition1 = 0; //Encoder initialization
    newposition2 = 0; //Encoder initialization
    encoder1Pos = 0;
    encoder2Pos = 0;
    else{
    newposition1 = newposition1; //Encoder signal
    newposition2 = newposition2; //Encoder signal
    count_old = count;
    Serial.println(count);
    //Encoder Read//////////////////////////////////////////////////////////
    void d1EncoderA()
    Bnew1^Aold1 ? encoder1Pos++ : encoder1Pos--;
    Aold1 = digitalRead(encoder1PinA);
    void d1EncoderB()
    Bnew1 = digitalRead(encoder1PinB);
    Bnew1^Aold1 ? encoder1Pos++ : encoder1Pos--;
    void d2EncoderA()
    Bnew2^Aold2 ? encoder2Pos++:encoder2Pos--;
    Aold2=digitalRead(encoder2PinA);
    void d2EncoderB()
    Bnew2=digitalRead(encoder2PinB);
    Bnew2^Aold2 ? encoder2Pos++:encoder2Pos--;
    }

    piZviZ wrote:
    Only data rate working is 9600  between labview and launchpad(arm cortex m4).Where all data rates work between Arduino serial port monitor and launchpad(arm cortex m4).
    Since the only thing that changed is the Launchpad, then that must be the issue.  Are you sure this device can handle more than just the 9600 baud rate?  Are you sure you are even setting the baud rate on this device?

  • ABS from MATLAB (simulink) to Labview (.vi file)

    Hello
    My Antiskid Control System project requires me to plot the graphs of wheel speed and vehicle speed. The original model is from Matlab simulink file-absbrake(this is an example of control)
    I tried to convert the whole system into labview representation. I donot want to use SIT or RT or any other Labview tools. I wanted to convert from Simulink model into Labview element-by-element. Can anyone help me...plss
    my due date for submission is 15march...so please help me

    abs.vi is the file that i attempted to 'convert' from matlab into labview
    Attachments:
    abs.vi ‏97 KB
    absbrake.vi ‏32 KB
    absdata.vi ‏1 KB

  • Transmitting more than 8 bits in labview through serial communication

    hello,
    i am working on communication through microcontroller and labview. My data is greater than 8bit. Can anyone may please help me in suggesting how to do it. Also i am interested in getting the real time images of the front pannel during the run time.
    Thanks

    You're going to have to split up your data among multiple bytes.  If you are sending 16 bit data, send it as two bytes.  32 bit data, four bytes.
    Look at split and join numbers VI's and also typecasting.
    You'll have to provide a little more description about what you mean by "real-time images of the front panel".

  • VISA Read function Read buffer problem in serial communication

    Hi,  I use VISA write and read function in serial communication app, the device continuously sends 0x00 if it is not receive a request from Labview program running on PC.
    And the request sent by labview is programmable. I met a weird problem, each time the request changes, the VISA read buffer output port still shows the last request firstly, from second time, shows the right request.
    It works like: Req code: ... 50, 51,51,51,50....;  VISA Read buffer: ...50, 50, 51, 51, 51, 51, 50....
    Please refer to the program.
    Attachments:
    readOne_test.vi ‏21 KB

    How are you running this?  You don't have a while loop around it.  Is it part of a larger VI?  Please don't tell me you are using the run continuously button.
    You don't have any wait statement between you VISA Write and your bytes at port.  So it is very likely the receive buffer is still empty since you didn't give your VI time to wait for the device to turn around and give a reply.  If you read 0 bytes, your VISA read string will be empty.  How does your decoder subVI (which you didn't include) handle an empty string?

  • Serial communication error

    hello,
    when i try to run my application(serial communication simple data transfer using loop back), labview evaluaton 8.6 showing the erron as attached.I dont understand what went wrong, it was working fine earlier.
    Thanks,
    hari
    Solved!
    Go to Solution.
    Attachments:
    laberror.JPG ‏85 KB

    Is that mean permission from NI? it was working fine, once i terminated the labview application abruptly when not responding since then i have this problem.
    hari

Maybe you are looking for

  • Sales Processing

    Hi Everyone, I'm trying to figure out what the correct process would be for the following situations: 1.  A sales order is created and copied to a delivery at the time of shipment.  The shipment is incorrectly processed with everything shipping (the

  • Frozen iPhone - apple logo with black screen

    My phone is frozen with the apple logo on the black screen. I have tried all the suggestions previously posted about holding the button while plugging in the USB...nothing works. It's FROZEN!! Can anyone help? I'm getting desperate.

  • Any way to remove rows without data so groupings and formulas can remain?

    Hi all, Does anyone know of a way (using a macro/Vba code) to remove zero or #missing rows from a spreadsheet so that groupings and formulas remain intact? Simple example: 7183.2224.0000     2000 7183 Misc Exp 1     2000 7430.2220.0000     0 7430.222

  • Joining the cube members in OBI

    Hi I have got the following members in cube : Years --- 2007 ---- 2008 ---- 2009 Year ---- Quarter ----- Month ----- Day and the other FACT members. Now When I am importing the cube into OBI there would be two separate tables and drill down would be

  • From scriplets to JSTL/EL

    Hi everybody! I'm working on a new project given by my boss. It uses struts framework. I have to translate some scriplets into JSTL and EL code in order to reduce the code. I'm working on a page wich lists requests made by the society's administrator