Subvi is not executable

labview 5.1
Once copied my vi's from sol 2.6 machine to sol 2.8, problem is:
"This Code Interface has no code to execute. Popup on it and select Load
Object Code ...,
then select the object code file (lsb)"
In fact, it concerns all the cin nodes including the ones of labview...
Saving development distribution by means of "Save with options" on 2.6
and copying intro 2.8 doesn't help
Thanks for ideas,
Alexandre

Hi Alexandre-
I am a little confused to what is happening, are you able to popup and select the lsb file and it still doesn't work? Or is the lsb file not present?
If the lsb file is no longer present, it probably got lost in your Operating System migration (2.6 -> 2.8)- you will just have to recompile your c code and recreate the object on the new system. This is not difficult and obviously you have achieved this already if your system was working properly. It does, however, require you to have the original source code which I really really hope you still have. If not, there is no present way of getting the source code from a compiled object - this "unfeature" is pretty standard in the CS field.
If the tlb object does exist and you are in fact selecting the file
and your vi is not acting like you expect, I would urge you to contact NI support and we can work through this together.
I think recompiling is the way to go - moving compiled objects from one system to another reeks of potential problems.
good luck, hope this helps-
ben schulte
national instruments

Similar Messages

  • Tried the solutions posted for this "SubVI filter not executable​. Undefined error" but not solving the problem

    Hello,
    I am trying to use a lowpass filter for my application but getting the error "SubVI filter not executable. Undefined error".I tried working with the solutions at this post 
    http://forums.ni.com/t5/LabVIEW/SubVI-filter-not-e​xecutable-Undefined-error/m-p/1996701#M657751 and results with
    1. Create a blank vi, put a VI filter in the block diagram (this should not be functional as it is not wired), copy it and paste it in my other project. I believe if the filter is the first vi of a blank project, it is funcitonal and then you may copy it wherever you need to.
    Result:
    2.Tried to open the filter panel of the Filter but showing the same error as shown inthe below image
    Don't why the solutions worked for others are not working.Can someone suggest a solution for this.
    thanks in advance.

    Hi PatanGova,
    Very strange error. Actually, there are no required inputs on this express VI, so it should be able to run even without wires. It is not correct as you said: "this should not be functional as it is not wired". Nothing will happen, true, but the run arrow should not be broken.
    For some reason, the VI with the Filter express VI fails to compile. I tried it on my computer (LV 2013) and get no error when I add it to a new VI. As was suggested in the linked forum thread, you need to open the front panel of the Filter VI and run it to see the explicit error.
    If you do, do you also get the error:
    "This VI claims to be part of a library that does not include the VI. The VI might have been deleted from the library. Add the VI to the library again or select File - Disconnect from the library."?
    If you do, it seems that you may have a project library somewhere that has taken ownership of the express VI. The ownership prevents you from running or editing the express VI. To free the VI, you need to do one of two things. Either, you need to load the library into memory, or you need to disconnect the VI from the library. Either way, you need to find the project library that has taken the ownership of the VI. As soon as it is released, it should run for you. You release it by selecting File»Disconnect from Library on the VI.
    The workaround described in your link (and also here: http://forums.ni.com/t5/LabVIEW/compatibility-prob​lem-labview-2009-2010-2011-quot-This-VI-claims/td-​... tells that you can make a copy of the VI and thereby create another instance that is free. This solution may work for you as well, but if not, you may not have created the copy properly. Maybe your copy of the VI also became part of some project library that took ownership. In either way, you should rather find the project library to release the VI before trying the workaround to copy it.
    If project library ownership is not the problem, maybe the problem is connected to LV 2011, as most forum posters report that it only happens here.

  • Subvi is not executable error, but it has no error

    Hey I hope you can help me with a weird error.
    I got the error "SubVi  'name' : SubVi is not executable" but when I click on the SubVi and open it it does not show me any description of an error. If I open the main vi or the SubVi alone it shows no error. Could it be a problem of a library or something else?
    I am using Labview 2012 and Labview 2012 Mindstorms NXT.
    If you neew more screenshots or the rest of the SubVis please tell me so :-)
    Thank you!
    Jan
    Attachments:
    automatischer Modus - ohne Wait - ohne Array - global.vi ‏80 KB
    Solar.vi ‏15 KB
    project.png ‏262 KB

    SmartCity-Project wrote:
    Thanks for all your replies!
    I found the error, the NXT does not support global variables in Target on NXT- Mode so I changed to Target on Computer - Mode and now it works.
    Unfortunately the program crashes after 15 minutes more or less. Could you imagine why? Is it because of to many bluetooth connections or a bad programm structure?
    After a very quick look at the code I would say that it is probably bad code. Your overuse of global variables, sequence structures and silly things like a For loop set to run once with everything inside the loop wrapped in a sequence frame is a goo dindication that you need to learn much more about data flow programming techniques. With the amount of global variables you are using your program is probably ripe with race conditions. In addition, you did not include any of the subVIs so we cannot see what is happening in them.
    Mark Yedinak
    "Does anyone know where the love of God goes when the waves turn the minutes to hours?"
    Wreck of the Edmund Fitzgerald - Gordon Lightfoot

  • Open Specific WorkBook.v​i: subVI is not executable error

    Hi,
    I'm trying to programaticaly change some cells of a specific worksheet and then saving it on a new file.
    But I can't run the VI because I get the error Open Specific WorkBook.vi: subVI is not executable.
    I've atteched a printscreen of my VI.
    Any hints?
    Daniel Coelho
    Daniel Coelho
    VISToolkit - http://www.vistoolkit.com - Your Real Virtual Instrument Solution
    Controlar - Electronica Industrial e Sistemas, Lda
    Solved!
    Go to Solution.
    Attachments:
    VI.JPG ‏16 KB

    This is the Open Specific WorkBook.vi with the error.
    Daniel Coelho
    VISToolkit - http://www.vistoolkit.com - Your Real Virtual Instrument Solution
    Controlar - Electronica Industrial e Sistemas, Lda
    Attachments:
    VI2.JPG ‏140 KB

  • SubVI filter not executable. Undefined error.

    Good morning,
    During the development of a bigger labview project, I came to need filtering of my waveforms at some point. I am getting a broken arrow signaling the filter assistant :
    "SubVI 'Filter' : SuvVI is not executable"
    I thought it could have something to see with the whole program and thus created a simple VI of acquisition from a myDAQ aparatus and had the same error.
    Do you have any idea how I could at least identify the error?
    Thanks in advance,
    David

    David Pastorino wrote:
    Good morning,
    During the development of a bigger labview project, I came to need filtering of my waveforms at some point. I am getting a broken arrow signaling the filter assistant :
    "SubVI 'Filter' : SuvVI is not executable"
    I thought it could have something to see with the whole program and thus created a simple VI of acquisition from a myDAQ aparatus and had the same error.
    Do you have any idea how I could at least identify the error?
    Thanks in advance,
    David
    If you open the SubVI Filter and hit Ctrl+R LabVIEW should tell you what you need to fix in that VI.
    When my feet touch the ground each morning the devil thinks "bloody hell... He's up again!"

  • SubVI not executable: many express VIs cannot be opened

    When I create an icon of an express VI on the Block Diagram, "error loading National Instruments\LabVIEW 2012\resource\lvanlys.dll" appears. And when I double click the icon, it is shown on the screen "unable to view properties". I cannot run the VI, and the errors listed are like "SubVI 'simulate signal': SubVI is not executable". I do not know how to solve this problem.
    Hope someone can help me. Thanks a lot!

    What do you mean "create an icon of an express VI on the Block Diagram"?  Give us enough steps to be able to reproduce (or test) your problem.  Include:
    Are you starting with a "blank" VI or a blank Project, i.e. starting from scratch?
    What is on the Block Diagram before you "create the icon of an express VI"?
    Which Express VI are you trying to use?
    Lily092 wrote:
    When I create an icon of an express VI on the Block Diagram, "error loading National Instruments\LabVIEW 2012\resource\lvanlys.dll" appears. And when I double click the icon, it is shown on the screen "unable to view properties". I cannot run the VI, and the errors listed are like "SubVI 'simulate signal': SubVI is not executable". I do not know how to solve this problem.
    Hope someone can help me. Thanks a lot!

  • .Not executable subVI

    Using LabView / fieldpoint with FP-1601, FP-TC-120 and FP-DO-410 I can use MAX to test the inputs and outputs, however when setting up any fieldpoint application in the labview window I get an error, of which states 'the subVI is not executable'.  I've checked and re checked but cannot seem to bypass this happenning.  There must be something small I'm not getting set up right.  Any ideas?  Thanks in advance.
    Steve
    Attachments:
    run1.vi ‏195 KB

    Hi Docbritzel
    Im not sure but maby this link will help you.
    regards
    Manuel

  • MS Office Report (Report Generation toolkit) is not executable​, Xnode broken?

    Hi, I am trying to generate an excel report, and I figured it would be easier to use the MS Office report VI, but I am getting the broken arrow saying the SubVI is not executable and that the library that defines the xnode is broken... here is a screensot attached, I already uninstall and reinstall the report generation toolkit and still the same... this is what I found on NI: "This error occurs when the library that defines the XNode you used is broken. To correct this error, reconfigure the XNode." but no idea how to reconfigure xnode
    Attachments:
    Error.png ‏67 KB

    What version of LabVIEW are you using?
    What is the nature of your Report?  What should it look like?  What kind of data should it contain?
    Can you show us some code that you've tried to use?  If so, include the code as either a Snippet or as a VI attachment (so we can plug it into our own LabVIEW installations and experiment with it).
    I generally find that the Report Generation Toolkit is a very easy way to generate Excel Workbooks.  I work primarily with LabVIEW 2012 and LabVIEW 2014.
    Bob Schor

  • Simulation interface toolkit: SUB VI not executable error

    Hi;
    I have a real-time application where I model things in Simulink and use Simulation Interface Toolkit to carry out hardware-in-the-loop simulations. As a real-time target, I am using NI-PXI8106 with NI-PXI6251 DAQ card on it. Up until now, I was able to run my code just fine. However, for some reason, my vi didn't work today and gave several errors such as:
    SubVI NI_SIT_sitclient.Lvlib:RVE.vi: SubVI is not executable
    Details:The SubVI is not executable. You must fix all error in the subVI before this VI can run.
    SubVI NI_SIT_sit Init Model.vi: SubVI is not executable
    Details:The SubVI is not executable. You must fix all error in the subVI before this VI can run.
    This is just few of many error that I received...In the details section of the error list window, the error statement are usually like the following:
    SUBVI not supported for current target..
    Type not supported in the current target...
    The only thing that changed since the last time I ran this program with success is the IP change of the target machine..However, when I use Measurement and Automation tool, I am able to access my target machine (PXI8106) without a problem...Maybe there are some certain rules for IP settings on the PXI target? ...I can provide the details of my new IP configuration numbers if necessary...
    I also  reinstalled the SIT 5.0 on the target machine but It didn't do the trick. I am wondering if there is anyone out there who can help me out with this problem..
    Thank you so much!
    Kind Regards.

    Hi there,
    I was just wondering if you did manage to solve this problem. I'm a new user and have recently started using the Simulation interface toolkit. I have created my model using Simulink and used the real-time workshop to convert it to a .dll file. I tried to run it on labview and it seems to build it on the realtime target, however as soon as map it to the hardware (using a NI BNC-2111,It's just a bunch of analog inputs and output which I have connected to a voltmeter), a dialog box pops up with the the following error:
    Error 1003 occurred during host VI initialization: SIT_test1.vi >> NI_SIT_sitclient.lvlib:sit Init Model.vi >> NI_SIT_sitclient.lvlib:sit Connect to Target.vi
    <append>=========================
    Simulation Interface Toolkit:  The driver VI (SIT_Test_Driver.vi) is not executable.
    Check the following:
    1) You have not modified the driver VI.
    2) You properly installed SIT and any necessary driver software on the target.
    3) The target has not been locked from Measurement and Automation Explorer.
    Do you want to launch the SIT Connection Manager dialog box and reconfigure the simulation?
    Please look at the JPEG picture attached below to see how the error looks on my monitor.
    Thanks
    Attachments:
    error1.JPG ‏135 KB

  • LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the VI in LabVIEW using File Open and verify that it is runnable.

    When trying to run a sequence on a deployment machine I get this error. When I switch the Adaptor back to the Development System the problem goes away however I do not have the luxury of keeping the full Labview development on the test machine. Is there a know fix for this problem and what is the cause of this error. Here is the software and versions I am using. It seems that the vi's that are broken are using Invoke and Property Nodes within them, I am not sure if this is just a coincidence. It appears it is more related to the invoke node than the property node. Any help is greatly appreciated. Why does it seem everything works great until you try and deploy it on a test machine. This is not the first time I have had these kinds of problems using Nation Instruments software.
    Labview 8.2.1
    TestStand 4.0
    Solved!
    Go to Solution.

    I have a similar problem.
    A bit of background - I had developed a test suite with a Labview front panel for manual operations, and a Teststand project which used some of the same lower level vi's, and specific test step vi's. It was developed on LV 2010 32-bit and Teststand 2010. All was fine.
    Recently i had to rebuild my development machine and installed only LV 64-bit 2011 and the latest (2010) Teststand from the 2012 Dev Suite.
    I knew that i wanted to run some new hardware drivers in 64-bit versions due to another problem, so i replaced the .dll in the very lowest level VI with the 64 bit version. And ran the manual interface. All ok.
    But when i try the Teststand execution, i get one of two errors:
    - If i set Teststand to use the LV runtime engine 11.0.1 (2011 SP1), the i get a "Unable to load VI xxxxx with the runtime engine version '11.0'" Despite the fact that each VI does run correctly in LV dev when loaded individually, and i've saved them as version 11.
    - If i set it to use the development system (which shows in the config menu 'active version:32-bit' even though 32-bit LV is not installed), then i get the "The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located." error, even though i when i open each VI in the LV 2011 it runs ok.
    Any ideas?
    How can i set TS dev system to use the 64-bit version? Or is there a separate 64-bit deployemrnt of TS?
    Labview 2010, TestStand 2010

  • ADO function error:SQL execute.vi is not executable​.

    Thanks for everyone who is willing to help me out of this problem that puzzled me several days,I can't find a similar one from Google or other forum..
    Problem:
    When I was using LabSQL,it come an error:
    Subvi "SQL execute":subvi isnot executable. and then I searched the source of the error,it was finally found to be the 
    "ADO Recordset GetString.vi":
    "invoke node:invalid method"
    "invoke node:invalid refnum class". 
    What I used is Windows 7 and LabVIEW7.1.
    Attached is the detail of this problem that includes the vi and some error pictures,and the ADO functions I used.
    ute.vi" is
    Attachments:
    Error.zip ‏1865 KB

    Duplicate - http://forums.ni.com/t5/LabVIEW/ADO-function-error​-SQL-execute-vi-is-not-executable/m-p/2397360#M742​...
    Try to take over the world!

  • VI seen as not executable from LV runtime, correct in LV development

    My current problem is the following:
    On the same PC, having TestStand 4.0 & LabVIEW Development 8.5, I try running a sequence with both adapters: LV development 8.5 and LV runtime 8.5.
    My sequence steps call VIs that call subVIs in a full hierarchy (let's say 1500 VIs are involved in a test sequence).
    The sequence runs with the development adapter, and with the runtime, I got a -18002 LabVIEW error: Vi not executable, broken, etc.
    Of course, when I open the VI within the development environment, everything is correct.
    As I'm testing both adapters on the same PC, the full hierarchy, including LV libraries provided with LV development are at the same location.
    Due to the large amount of VIs I use, I cannot guess which LLB could be missing or not inaccessible.
    Is there a way to investigate the cause, despite the fact that everything is correct under the development environment?
    Is it possible to tell the LV runtime where it should search for LLBs or other required dependencies that the LV development seams able to find?
    Thanks in advance for your help,
    JJD
    Solved!
    Go to Solution.

    Hello,
    I've seen this error when two VIs withthe same name were loaded in memory; this VI was called from a TestStand sequence and from the user interface (very poor design of a customer that I will not mention ^^).
    I'm not sure to understand youy problem: everything works fine when you are using Developpment system (Active Version 8.5) but, do you have this error when you set the adapter to LabVIEW Run-Time Engine 8.5, right? Are LabVIEW and/or VIs used in your sequence open when you run your sequence in Run-Time mode?
    Cordially,
    .mrLeft{float:left} .mrInfo{border-left:solid 1px #989898;font-size:x-small;color:#989898}
    Mathieu R.  
      CTD - Certified TestStand Developer / Développeur TestStand Certifié  
      CLAD - Certified LabVIEW Associate Developer  

  • BPM send step not executed in BPM (after Message split)

    Hello everybody,
    we use BPM:
    We have a paralell Block which should send the rows of a multiline element. In SXMB_BPE_MONI the send step is not executed?
    Any idea?
    Thanks  lot, regards Mario

    HI,
    Go to SXMB_MONI_BPE->and check the workflow log (technical details).and go to SXI_CACHE and check the return code of the Integration Process. It should be zero. If not try to activate the same
    If there is no error then go with like this-
    Also check the Syntax in Integration Repository with F7. Change the IP and activate it. If there is no syntax errors.
    Then reimport the IP into Directory and then test your scenario
    Regards,
    Moorthy

  • Subvi does not work properly when called inside a vi

    Hello Every body
    thanks for your help. i am using a sub vi for sine signal generation. as a vi it works fine. but when i called this subvi inside another VI it gives some problems. for example timer indicator works properly.it reinitializes as well in the sub vi, but in the main VI it does not work properly. means does not count the time.in the sub vi on the fly i can change the values of frequency and amplitude in real time, but when i use as sub vi, it does not reponse as i change the values in the control arrays.similarly pause and continue works properly in the sub vi, but once again in the main VI, it does not work properly.graph indicator also work properly in the sub vi. but here once again it does not work properly in the main VI.the pause resume indicator also does not blink, when it is continue. in the subvi it blinks very well.generally why the sub vi does not work properly inside the VI?i am sending my VI and sub vis.
    any tips would be highly appreciated.
    thanks
    Regards
    Attachments:
    vi.zip ‏87 KB

    I just want to add some more details to Dan's answer. The subVI is acting exactly like you've coded it. The mistake is in understanding how subVIs work. When you call a subVI (or a function in any other language), you pass some parameters to it, the subVI does it's thing and returns values. the subVI does not accept new parameters from the calling VI until it returns to the caller and the caller runs the subVI again. In your case, you have a subVI with a while loop. You have some front panel control wired to the subVI's stop terminal. When first called, the value is false. So the subVI will keep running until the subVI's stop button becomes true but you cannot change it from main until the subVI finishes and returns so the subVI will never stop. As Dan says, the solution is pass references of front panel controls to the subVI and have the subVI monitor those references for changes and to update references to indicators on Main. You subVI does not need any front panel controls or indicators of it's own.

  • I recieve the following error when running an executable ("This VI is not Executable. The full development version of Labview is required to fix the errors"

    I recieve the following error when trying to build and run a labview executable. I am able to build the executable but when trying to run the executable, a pop up window comes up asking the user to select a dll. (please see screen shot attached). Once the DLL is selected, I get the error that This VI is not Executable. The full development version of Labview is required to fix the errors. (please see screen shot attached). I have also attached a snapshot of the project window.
    I have the professional development system
    I can run the main VI
    all the required DLL's are in the dependencies section of the project window.
    I am trying to find the root cause of this error but to no avail. can anyone give me a clue to what i am missing here. Any suggestions on where i should look to find the problem ?
    Thanks in advance to all labview users for your help
    Attachments:
    project window.PNG ‏36 KB

    other PNG
    Attachments:
    Broken Arrow on EXE.PNG ‏179 KB

Maybe you are looking for

  • Song doesn't show in ''bought'' list

    So i bought a song on itunes and downloaded it on my brand new laptop. I want to send it to my iphone but i know that if i sync my device, i will loose a ton of songs that i didnt buy on itunes but imported from my cd's. I know there's a way to downl

  • Collection to represent ol ul il structures in recursive function

    Hello Im trying to write a terminal based web-browser and have a little problem when it comes to presentation of <ul><ol><li> tags. Im using recursion to step through the tags and the main function looks something like this (just wrote down a simplif

  • Can I use iTunes gift card for in-app purchases?

    I already tried doing it but Apple Support error keeps popping out. An unknown error/transaction error. How do I fix this?

  • Acrord32.exe /h /p does print but results in there was an error

    When using Acrord32.exe /p /h "pdfname.pdf" "Myprinter" in a .Bat File The document is printed but the adobe reader does not close. It comes with an error "There was an error opening this document, This file cannot be found. Checked version 7.0 and 8

  • JMF - video + subtitles ?

    hello everyone, I know the JMF supports only video and audio formats. How can a .srt file (subtitles) or something similar be viewed together with video ? I know SLIM can do the job (viewing both) but I don't think it's capable for media player devel