Test Stand intermitte​nt error/cras​h problems

I've been experiencing an intermittent crash problem on TestStand 4.0 for a long time.
Previously, I got customer support on this issue (Reference#7226468)
and they suggested repairing Test Stand to solve the problem. It seemed the repair solved the problem for a while. But after one month w/o crash, I got the same Run-time Error/crash,
with following messages:
“Microsoft Visual C++ Runtime Library Error”,
“Sequence Editor: Operation failed, error code: -17500”,
“Sequence Editor: Can’t get type palette file list; they must be loaded
first, error code: -17500 Oparetion failed, Source: TSAPI”, etc.
How can I solve this issue?Regards,
Pelin Y.
Test Systems Design Engineer

Pelin,
I would recommend trying to repair TestStand
again if it worked the first time, but having to repeatedly do so could
become bothersome.  Did you change anything in the code between when it
worked and when you get this error? Do the errors come from the same
step in your execution as the did a month ago? If so what is happening
in your code when you get these errors? Have you seen this same error
on any other machines? Are you calling a C++ DLL and if so what version
of Visual Studio do you have on the machine?
Richard S -- National Instruments --Applications Engineer -- Data Acquisition with TestStand

Similar Messages

  • Test Stand Deployment; Internal Error Code 1

    Hi,
    I get the following message from the deploymeny tool when trying to deploy my system...
    Internal error code 1 Processing VIs...
    An installer was not created due to an error
    I have mass compiled everything and all the VIs are working, my workspace processes okay and the sequences run okay in the Run time Engine adaptor of Test Stand.
    Any ideas what could be causing this? I have Test Stand 4.0.0 and labview 8.5.
    Many thanks
    Matt

    Hi Rick, see below cut and paste from this file, does this help?
    08:55:43tarting Log.
    08:55:45tarting Analysis
    08:55:45tarting to process workspace file
    08:55:56one processing workspace file
    08:55:56:Finished Analysis
    08:55:57:Building...
    08:55
    08:57:01:Internal error code 1 Processing VIs...
    08:57:01:Could not process LabVIEW VIs. Fix any broken VIs before rebuilding. LabVIEW error:
    Error copying files.
    Source:
    Destination: <Not A Path>
    Librarian Path Location.vi
    <Call Chain>Error 1 occurred at ABAPI Dist Copy Non-VI Files.vi -> ABAPI Dist Build LLB Image.vi -> ABAPI Copy Files and Apply Settings.vi -> TestStand - Build VI Distribution 8 AX Wrapper.vi -> TestStand - Build VI Distribution 8 AX Wrapper.vi.ProxyCaller
    Possible reason(s):
    LabVIEW:  An input parameter is invalid. For example if the input is a path, the path might contain a character not allowed by the OS such as ? or @.
    =========================
    NI-488:  Command requires GPIB Controller to be Controller-In-Charge.
    08:57:01:An installer was not created due to an error
    08:57:01:The build is finished
    08:57
    08:57:01:Aborted
    08:57:01:---------------------------------------
    Many Thanks
    Matt

  • Test Stand 3.5 install problem

    I'm having problems installing Test Stand 3.5 Development Edition on a WinXP SP1 machine - would anyone have any suggestions.
    I'm performing a custom install and selecting all components other than "Device Drivers".
    The install fails on "NI TestStand 3.5 Support Files. Part 1 of 1" with "Error 1335. The cabinet file 'Cabs.m6' required for this installation is corrupt and cannot be used. This could indicate a network error, an error reading from the CD-ROM, or a problem with this package".
    If I select abort at this point the install of the support files is rolled back and the remaining components apper to install correctly. I can now run Test Stand but am missing the help files. If I rerun setup it attempts to install the support files but fails with the same error.
    I have tried uninstalling and reinstalling & have copied the CD contents to the local hard disk (without any problems) and installing from there. All this is to no avail.
    I've also uninstalled and reinstalled an installation on a second machine using the same install media. This install succedded with no issues.

    What is the difference between the two machines - where you've had successful and unsuccessful installs?
    Like you've said sometimes this is caused by a faulty read from the CD drive, or faulty media, but as you've managed the install with the same media on the machine - then its not the media, and you've already tried the copy to hard disk from the CD without any luck. 
    What OS is on this other (working) machine?
    Do you have administrator privileges on the machine where you can't install the software? Is the .NET framework 1.1 installed (I think this is part of Windows XP SP 2) so this could be the issue - as TestStand requires the .NET framework 1.1
    Also - I've attached the readme which includes information to consider before installation - and known issues with the installation - check this and see if any of these could be the issue with this machine.
    I hope this helps
    Regards
    Hannah
    NIUK & Ireland
    Attachments:
    ReadMe.txt ‏51 KB

  • Error when closing test stand

    when i try to close test stand after i run a test, i got the error in the
    attached file.
    this error appear only if i dont close the sequence file before i exit test
    stand and only after i run a test.
    please help me.
    advanced thank's.
    [Attachment error.jpg, see below]
    [See first answer for additional information]

    Hello Avi,
    The error is caused by TestStand not being able to finish the LoginLogout sequence before its time limit. These limits are set under Configure >> Station Options >> Time Limits. They will allow you to interrupt a sequence that is taking too long to shut down.
    The real problem may be in the LoginLogout sequence, in the file \Components\User\Callbacks\FrontEnd\FrontEndCallbacks.seq (or substitute "NI" for "User" in the path). If something in that sequence doesn't finish executing within 10 seconds, due to an extreme slowdown or a problem with the sequence, you will see this error. If you have modified that sequence, this could be the cause. You will need at least two steps in the sequence, one for Login and another for Logout. They should
    reference frontend.dll. If you have a modified callback in your User directory, trying copying the default callback from the NI directory.
    Also, make sure that you complete or terminate other sequences before trying to close TestStand, or you will see a similar error message.
    Good luck and feel free to ask if you have further questions.
    Steven Reasoner
    Applications Engineering
    National Instruments

  • Test stand Error while running

    Hii friends,,
    i am facing 1 problem while running the Test stand...... can any 1 suggest me the solution for this..... 
    Attachments:
    Error.doc ‏146 KB

    Hi,
    you can check out the following link
    http://digital.ni.com/public.nsf/allkb/7A806984E7ACB66E86256A50006C2F26
    but I think it might be that you have not got the VI Server access enabled in your LabVIEW preferences.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • Test Stand 2010 Deployment tool Error

    Dear All,
    Whilst attempting to deploy a Test Stand system I am coming across the following error:
    Error: Unable to find all subVIs from saved VIs. Either a subVI is missing or the VI is not saved in the current LabVIEW version.
    The call chain to missing VIs:
    1 - initialise_resistor_card.vi
        2 - pipx40 Initialize.vi (missing)
    I have the Teststand Adaptor set to Labview Run-time Engine --> "Auto detect using VI version"
    This is a new feature in Test Stand 2010 right? So is the deployment tool also able to inherit the ability to auto detect the version of runtime engine to use on a deployed machine?  
    Any ideas?
    Regards
    There is no problem with the VI within the sequence.
    I've encountered this before before with the deployment tool and usually mass compilling or opening and closing the VIs heirarchy helps, but in this case I just can't get the deployemnt tool to process these VIs.

    Hello,
    So it would appear that the VIs giving the problem are within .llb . 
    If I open and save them again within the .llb and mass compile the .llb then the same happens, but if I take the VI out of the llb then the problem goes away?
    Is there any known issues with the Deployment Utility failing to find VIs with llbs? I notice TS 2010 deployment utility introduces the idea of a Packed Project library option rather than the old SupportVIs folder, could using this be the issue?
    Regards
    Matt

  • How to solve conflict errors using Test stand 4.1

    Hi,
    I am using Test stand 4.1. Previoulsy I was using test stand 4.0. When I am trying to open the sequences saved in 4.0 in 4.1 they are giving some conflict errors. So now my problem is if I have a big main sequence in which I have many more child sequences then I was required to open all the sequences that being called in the main sequence save it and close.
    One thing I found is that if once I opened and saved all the child sequences present in the main sequence then it will run fine. i.e. once I clear the conflict error with all sequences, this data is stored in the station globals. If change this again I will be required to do the same job.
    This is costing me a lot of time.
    Please help me in avoiding this conflict error.

    NI Labs has a utility that I have used to check for type confilcts.  Check it out...
    NI TestStand Toolkit for Large Application Development
    http://www.ni.com/labs/

  • How To Trigger Test Stand To Assign Step = Error

    Hi everyone, I have a LabVIEW VI step in my sequence and I have an abort button the user can select to abort the user interface VI.  I want the "abort button" boolean to pass back to test stand that abort button = TRUE and I want the sequence step to be set to an "ERROR."  Is there a command to send to the Test Stand Engine to flag this step as an error?
    Thanks so much!
    Solved!
    Go to Solution.

    Hi
    Glad It was helpful.
    There are two ways in which you could achive this..
    1. Use this expression: RunState.Engine.TerminateAll()
    But be wary, this will terminate all the current excutions and the report indicates the status as "terminated"
    or
    2. Use this expression: RunState.Execution.Terminate()
    or
    3. You can add a Goto step (comes with teststand. You can find it under Flow Control section of the insertion palette) and select Cleanup as the destination step.
    This way you can run some clean up steps before closing the execution. (eg, Shutting down any hardware, etc.,)
    Deepak

  • CodedUI Tests Fails Intermittently With Initialization Errors

    I would like to re-ask the question asked in this thread:
    https://social.msdn.microsoft.com/Forums/vstudio/en-US/855c561b-2100-4494-bf65-c5b9ec83e4af/inconsistent-coded-ui-test-behavior-depending-on-lab-size?forum=vsmantest
    There was no answer given and no more replies coming in to that thread.
    We are exactly in the same situation. We have large number of CodedUI test cases (500+) which runs daily. Some of the tests fails intermittently with the initialization failures. The details are:
    ERROR MESSAGE
    Error calling Initialization method for test class TEST_CLASS_NAME: System.Runtime.InteropServices.COMException: Error HRESULT E_FAIL has been returned from a call to a COM component.
    ERROR STACK TRACE
    Microsoft.VisualStudio.TestTools.UITest.Playback.Engine.IRPFPlayback.SetSkipStepEventName(String skipStepEventName)
    Microsoft.VisualStudio.TestTools.UITest.Playback.ScreenElement.InitPlayback()
    Microsoft.VisualStudio.TestTools.UITesting.Playback.Initialize()
    Could someone please let us know what could be the issue of these intermittent failures?

    Hi digitali,
    According to your description, I would like to know the details:
    How many agent machines in the lab environment?
    What’s the details of these machines? (e.g. memory, system)
    What’s the version of TFS, MTM, test controller and test agent?
    Regards
    Starain
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

  • Is there a way to create a database with Test Stand?

    Anyone know of a way to have Test Stand create a database? My company standard MS Office suite is Microsoft Access 2010, and TestStand does not support the .accmdb extension type(format), so I have to create new databases using old formats. I'm worried about backwards compatability down the road since good ole Microsoft doesn't seem to care about legacy formats.
    I'm still a beginner with databasing, so any suggestions would be greatly appreciated.

    TestStand 2012 SP1, and  we are using a modified Generic Recordset (NI). The problem we are having right now is that the Build SQL instructions are not creating the database tables the way we are configuring them from the "Statements" and "Column/Parameters" tabs under Database Options.
    What is happening is when we validate the schema, and drop all schema tables, it empties all the database tables, but then when you build using the TestStand generated sql file, we get errors(shown below) we are not understanding, and we can no longer write to the database and LabVIEW throws a "Data type mismatch in criteria expression" error like this
    "Possible reason(s):
    ADO Error: 0x80040E07
    Exception occured in Microsoft JET Database Engine: Data type mismatch in criteria expression. in NI_Database_API.lvlib:Conn Execute.vi->TSData - Query Actions.vi->Retrieve Test Data.vi->ARA-63 Data Miner.vi->ARA-63 Data Miner.vi.ProxyCaller"
    ==================================================================================================== > CREATE TABLE UUT_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STATION_ID VarChar(255), BATCH_SERIAL_NUMBER VarChar(255), TEST_SOCKET_INDEX Long, UUT_SERIAL_NUMBER VarChar(255), USER_LOGIN_NAME VarChar(255), START_DATE_TIME DateTime, EXECUTION_TIME Double, UUT_STATUS VarChar(32), UUT_ERROR_CODE Long, UUT_ERROR_MESSAGE VarChar(255), PART_NUMBER VarChar(255), TSR_FILE_NAME VarChar(255), TSR_FILE_ID VarChar(64), TSR_FILE_CLOSED Bit, PART_NAME VarChar(255), PRG VarChar(255), Comment VarChar(255), Operator VarChar(255)) Command issued.
    > CREATE TABLE STEP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, UUT_RESULT Long, STEP_PARENT Long, ORDER_NUMBER Long, STEP_NAME VarChar(255), STEP_TYPE VarChar(255), STEP_GROUP VarChar(32), STEP_INDEX Long, STEP_ID VarChar(32), STATUS VarChar(255), REPORT_TEXT VarChar(255), ERROR_CODE Long, ERROR_MESSAGE VarChar(255), CAUSED_SEQFAIL Bit, MODULE_TIME Double, TOTAL_TIME Double, NUM_LOOPS Long, NUM_PASSED Long, NUM_FAILED Long, ENDING_LOOP_INDEX Long, LOOP_INDEX Long, INTERACTIVE_EXENUM Long, CONSTRAINT STEP_RESULT_FK FOREIGN KEY (UUT_RESULT) REFERENCES UUT_RESULT (ID)) Command issued.
    > CREATE TABLE STEP_SEQCALL ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, SEQUENCE_NAME VarChar(255), SEQUENCE_FILE_PATH LongText, CONSTRAINT STEP_SEQCALL_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, PROP_PARENT Long, ORDER_NUMBER Long, NAME VarChar(255), PATH LongText, CATEGORY Long, TYPE_VALUE Long, TYPE_NAME VarChar(255), DISPLAY_FORMAT VarChar(32), DATA Double, FORMATTED_DATA VarChar(255), CONSTRAINT STEP_NUMERICLIMIT1_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_NUMERICLIMIT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, COMP_OPERATOR VarChar(32), HIGH_LIMIT Double, LOW_LIMIT Double, UNITS VarChar(255), STATUS VarChar(255), HIGH_LIMIT_FORMATTED VarChar(255), LOW_LIMIT_FORMATTED VarChar(255), CONSTRAINT STEP_NUMERICLIMIT2_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, PROP_PARENT Long, ORDER_NUMBER Long, NAME VarChar(255), PATH VarChar(255), CATEGORY Long, TYPE_VALUE Long, TYPE_NAME VarChar(255), DISPLAY_FORMAT VarChar(32), DATA VarChar(255), FORMATTED_DATA VarChar(255), CONSTRAINT PROP_MULTINUMERICLIMIT1_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID), CONSTRAINT PROP_MULTINUMERICLIMIT1_FK FOREIGN KEY (PROP_PARENT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_RESULT' already exists. (-2147217900)
    > CREATE TABLE PROP_NUMERICLIMIT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, COMP_OPERATOR VarChar(32), HIGH_LIMIT Double, LOW_LIMIT Double, UNITS VarChar(255), STATUS VarChar(255), HIGH_LIMIT_FORMATTED VarChar(255), LOW_LIMIT_FORMATTED VarChar(255), CONSTRAINT PROP_MULTINUMERICLIMIT2_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_NUMERICLIMIT' already exists. (-2147217900)
    > CREATE TABLE PROP_RESULT ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, STEP_RESULT Long, PROP_PARENT Long, ORDER_NUMBER Long, NAME VarChar(255), PATH VarChar(255), CATEGORY Long, TYPE_VALUE Long, TYPE_NAME VarChar(255), DISPLAY_FORMAT VarChar(32), DATA VarChar(255), FORMATTED_DATA VarChar(255), CONSTRAINT PROP_RESULT_FK FOREIGN KEY (STEP_RESULT) REFERENCES STEP_RESULT (ID)) Command failed with the following error...: Table 'PROP_RESULT' already exists. (-2147217900)
    > CREATE TABLE PROP_ANALOGWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_T DateTime, DELTA_T Double, INITIAL_X Double, DELTA_X Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_ANALOGWAVEFORM_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_DIGITALWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_T DateTime, DELTA_T Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), TRANSITIONS LongBinary, DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_DIGITALWAVEFORM_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.
    > CREATE TABLE PROP_ANALOGWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_X Double, DELTA_X Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_IVIWAVE_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_ANALOGWAVEFORM' already exists. (-2147217900)
    > CREATE TABLE PROP_ANALOGWAVEFORM ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, INITIAL_X Double, DELTA_X Double, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, ATTRIBUTES LongText, CONSTRAINT PROP_IVIWAVEPAIR_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command failed with the following error...: Table 'PROP_ANALOGWAVEFORM' already exists. (-2147217900)
    > CREATE TABLE PROP_BINARY ( ID COUNTER CONSTRAINT TABLE_CONSTRAINT PRIMARY KEY, PROP_RESULT Long, UPPER_BOUNDS VarChar(32), LOWER_BOUNDS VarChar(32), DATA_FORMAT VarChar(32), DATA LongBinary, CONSTRAINT PROP_BINARY_FK FOREIGN KEY (PROP_RESULT) REFERENCES PROP_RESULT (ID)) Command issued.

  • Intermittent Runtime error - pure virtual function call

    I have an intermittent runtime error - pure virtual function call & don't know what cause it? Since It only occurs & crashes once awhile therefore it's difficult to trap it for debugging.I suspect it come from TestStand ActiveX API which I use in my User Interface Application project but I'm not really sure.
    Does anyone experience this kind of problem when working with TestStand API ? If so any
    suggestion? I have noticed in the TestStand API header file teapi.tlh contain many raw_.... function defined as pure virtual function. What are these raw_... function ? I don't think I use any of these function in my project.
    Many thanks!

    Danh,
    I don't believe that your problem can be solved with the information you have provided unless someone else has experienced the same symtpoms which coincidentally have the same cause as in your case.
    Is there any other information you can provide that can help localize the problem?
    1) What is happening when the error occurs?
    2) Does the error always occur in the same place?
    3) Does it always occur with use of certain resources (e.g. DAQ, GPIB, VISA, printer)?
    4) Does it occur when using the sequence editor?
    5) Does it occur when using one of the shipping operator interfaces?
    6) Does it occur only when using your operator interfaces?
    7)Is it related to a specific sequence or any sequence?
    8) Does it happen when you executed your sequence with/without a process model entr
    y point (i.e. Execute>>Test UUTs, Execute>>Singal Pass or Execute>>Run MainSequence)?
    9) How often does it happen?
    10) What version of TestStand are you using?
    11) With what language (include versions) are you programming your code modules?
    12) With what language (include versions) are you programming your operator interface?
    13) Is there any error code reported with this error message?
    14) Is this error reported in a TS run-time error dialog or is it reported directly 1by the operating system?
    15) Have you searched the web for related errors? For example, the following link describes a particular programming mistake that can lead to this error
    http://support.microsoft.com/support/kb/articles/Q125/7/49.asp
    By investigating answers to the above questions you may be able to narrow the cause of this error, which might allow you or others to help solve the problem.

  • Test stand crashes: "test stand has detected that your script debugging"

    05-01-201203:18 PM
    Hi everyone. I am setting up a new installation of Test stand and writing my first sequence with an existing sequence of legacy code.
    When I run the sequence and stop on the call to the DLL, and then step into the dll and I get this error:
    test stand has detected that your script debugging settings might cause visual studio to hang when attaching to the teststand process to perform this step into operation.
    To fix this problem, open internet explorer, select tools>>Internet options>> Advanced, check Browsing>>Disabl script debugging, click okay, and restart your sequence execution.
    The message is vague and it is indermanent as to whether I should "enable" or "disable" Script debugging so I tried both. Test stand then crashes again and I get the same error.
    Do I need to reboot after each crash? I'll try that next. Any ideas on how to make this error go away?
    Thank you for your help.
    Richard

    This is a duplicate. Please go here instead:
    http://forums.ni.com/t5/NI-TestStand/quot-test-stand-has-detected-that-your-script-debugging-quot/td...

  • Added a check to Text to sequence file result in Test Stand hang up.

    I added the check in text to sequence file translator.vi (the file is attached)
    With this addition I generated the dll.
    Test Stand load the sequence file without any problem for the first time.
    If I add a space to the sequence file and save the file; test stand tries to load the new sequence file saying file has changed do you want to load the new sequence...
    But fails to load the sequence (Test Stand hangs up)
    The only way to overcome is kill the TestStand thru task manager.
    Which displays
    "You chose to end the nonresponsive program, SeqEdit.exe"
    Attached the displayed error (error.doc)
    Attachments:
    Changed code.vi ‏55 KB
    Error1.doc ‏45 KB

    Hi Vidula,
    Is it only when you add a space to the file name that you see this behavior? If, for instance, you add a '1' to the beginging of the file name does the same thing happen?
    Adam
    National Instruments
    Applications Engineer

  • Can labview call a test stand module

    Having problems with a test dll that runs in test stand, but I get errors when trying to use the wizard in labview, however I can use the call library function node to protypye it.  Problem - the function openComserialPort(char* comPort, ErrStruct & err), how do you difine the parameters for the ErrStruct & err part.
    next Question, since this Dll runs in Test Stand, is their anyway to export to work in LabVIEW. 
    Solved!
    Go to Solution.

    Here's a description of the dll, to start off, I have a circuit board with a microprocessor on it, that has control for a radio module.  During test I need to program this board serially through its' TX and RX lines on the processor.  The dll given to me, which was written for test stand, has functions to enable me to do this programming.  There are basically  11 function contained is this Dll. 
    Initialize Dll, (no errors),
    open serial port, (no errors), 
    getStandardTable, which sends a command for the microprocessor to send back its information-> get assertion error
    WriteHardwareVersion -> Sends the version and revision number -> assertion error.
    ColdStart -> Which resets board statistics variables -> assertion error.  Now, this function prototype is ColdStart (errStruct & err); So I prototype like I did for the above error struct, but still got an assertion error, which leaves me to believe, that , or vendor, has a bug communicating, or sending the commands via serially, to test this, I could use the serial examples contained in LabVIEW, however I don't know the command set of the microprocessor, or could there be something else wrong,  Any ideas will be appreciated.

  • Test Stand Shut Down with no reason

    Hello ,
    I'm using Test Stand 4.2 & LabWindows CVI 9.0 .
    I'v created a program that checks 30 cards in Batch mode , using Test Stand as master that calls CVI functions from dll files i'v created .
    In the program there are no error nor warnings But i have a strange problem for every 50 runs of the program I'm facing 1 Complete shut down of TS with no reason or warning .
    TS simply shut down and not showing any message . This problem is very disturbing considering that full check for 30 cards using TS is Approximately 3.5 hours .
    The shut down can occur at any part of the run with no repeated pattern , It can happen after 3 min or after 3 hours And by doing so the user need to restart the entire test from the start because TS 
    didn't produced any Report .
    I'm not denying that the crash can be in the dll files written in CVI but thats in low possibility .
    I'm under Win Xp and using intel core2duo L7400 and 4 MB of RAM . 
    Is there any option to avoid this problem ??
    Thank You , Kobi . 
    Kobi Kalif
    Software Engineer

    Thank u Doug i will check it , for now i have pasted the at the bottom the event viewer application log maybe some as i suspected the problem is in the CVI DLL but i don't know what this Error means 
    Maybe You know ?
    The description for Event ID ( 0 ) in Source ( CVI ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. The following information is part of the event: [11:22:25.140] [FATAL] [LRemoveItem] [..\james\list.c:543] Assertion failed: 0 (itemPosition >= kEndOfList && itemPosition <= (*theList)->numItems).
    The description for Event ID ( 0 ) in Source ( CVI ) cannot be found. The local computer may not have the necessary registry information or message DLL files to display messages from a remote computer. You may be able to use the /AUXSOURCE= flag to retrieve this description; see Help and Support for details. The following information is part of the event: [11:18:43.140] [FATAL] [LRemoveItem] [..\james\list.c:543] Assertion failed: 0 (itemPosition >= kEndOfList && itemPosition <= (*theList)->numItems). 
    Kobi Kalif
    Software Engineer

Maybe you are looking for

  • Firefox crashes when I try to rewind or fast forward netflix?

    I have a weird problem with netflix I've been dealing with for awhile and it BUGS me to no end. Whenever I try to fast forward or rewind on netflix, the browser freezes up and then my whole computer is frozen and dead. I can click on the progress bar

  • T500 wont shut down

    Hello there ! We have big problems with our Lenovo T500 model 2241 CTO. We are running Windows Vista on them. The problem is when we are shutting down, they mostly dont shut off correctly. It seem that windows are shutting down, but when the screen t

  • Using FaceTime For Clients in Travel Company

    We own a travel agency in Canada with clients across Canada and US - We would like to use faceTime interact with our clients.  Is this possible?

  • How to see the GL Accounts balance carry forwarded date

    hi gurus can you help me, how to see the date of last GL accounts Carry forwarded? thanks in advance amk

  • Shortcut to make a new slide