Teststand full featured ui doesn't show breakpoints

Hi,
I am using the full-featured UI of TestStand within a LabVIEW program.  When I set breakpoints in the sequence, then save the sequence, then open the sequence within the full-featured UI, the breakpoints do not appear.  The breakpoints do appear when I open the sequence normally via TestStand.
Is there some way for the breakpoints to appear within the Full-Featured UI?
Cheers.

AK01 -
When no workspace is loaded, the TestStand engine saves the breakpoint information to the <TestStand Cfg>\TeststandPersistedOptions.opt file. When a workspace is loaded, the <workspacename>.opt file is used. However, the engine typically saves the .opt file when the workspace is saved. For the non workspace case, the engine lazily updates the <TestStand Cfg>\TeststandPersistedOptions.opt file, so I suspect that you would have to either change the workspace state by loading or closing the current workspace or close the sequence editor. The UI will only see the new settings in the .opt file when you launch it or when you change its current workspace.
Scott Richardson
National Instruments

Similar Messages

  • TestStand Full Featured Labview OI - Documentat​ion?

    Can anyone point me to any documentation/examples out there for the TestStand Full-Featured Labview OI? I have tried looking just about everywhere and can't seem to find any good documentation/explainers on how the OI works and how to customize it. I am new to TestStand OIs and am trying to create an OI that allows me to run up to 6 different UUTs independently at the same time. I can't figure out how to wire in each individual Execution Entry point and am looking for examples and/or documentation. I also need some help with Progress bars and test status indicator LEDs.     

    Below is an example front panel of what I am trying to accomplish. Most of the controls are not connected of course :-). I am trying to have one window with 6 different executions shown within it. Each execution would be seperate from one another and you would be able to view each just by clicking on the tab for that particular test fixture. The only thing that would be common is that each execution would be running the same sequence file. The individual test fixtures could be at different points in the test sequence and could have different start and stop times for each. For instance....test fixture #1 could be loaded with a UUT and started into test then while it is running test fixture #5 could be loaded with a UUT and started into test. In the meantime when test fixture #1 has finished testing I could load another UUT into test fixture #1 while test fixture #5 is still running. etc etc
    Attachments:
    MultiUUT.JPG ‏155 KB

  • In Snow Leopard, there was a quick look feature that allowed you to look at files without opening the program.  It doesn't show up in Lion on my iMac.  Any ideas?  Thanks

    In Snow Leopard, there was a quick look feature that allowed you to look at files without opening the program.  It doesn't show up in Lion on my iMac.  Any ideas?  Thanks

    While in Finder, select the file (click on its icon once) then press the Spacebar.

  • How can I get photo of callers to vshow full page since I just did the update it doesn't show but a thumbnail pic

    How can I get photo of callers to vshow full page since I just did the update it doesn't show but a thumbnail pic

    That is the design in iOS 7.1 and there isn't any way to change it. You can provide feedback to Apple if you want: http://www.apple.com/feedback/

  • I have an ipod nano 5th generation. the problem with it's that it doesn't show in itunes when connected to the laptop and it switches on on its own and songs start playing the battery gets consumed too fast after full charge. what is the actual problem?

    i have an ipod nano 5th generation. the problem with it's that it doesn't show in itunes when connected to the laptop and it switches on on its own and songs start playing the battery gets consumed too fast after full charge. what is the actual problem?

    What have you tried so far in terms of troubleshooting this issue?  Are you plugging the iPod into a high powered USB 2.0 port on the back of your PC? Have you tried a different USB cable?
    What happens if you try to reset the device with it still connected to the PC?
    How to reset iPod
    Has this iPod ever worked on this PC or is this the first time you have time you have tried connecting it?
    Have you carefully worked through each and every single suggestion in this Apple support document?
    iPod not recognized in 'My Computer' and in iTunes for Windows
    B-rock

  • How can I remove some menu items in the VC++ "Full featured" example that came with TestStand 3.5.

    The full featured operator interface example of VC++ contains several menus such as File, Execution, Debug, Tools, and Help.  I would like to remove or gray out some of the items base on the access privilege of the user's login.  For instance if a user login as admin, I would turn on all the features. However, if an operator login to run a test sequence, I would only provide limited menu options.

    The display of the menu items is already depending on the user's privilieges.
    1/ Modify the privileges of each user profile to enable or disable some menu accesses (Look at "Using TestStand" manual, chapter 7).
    2/ If you need to change the TestStand default behaviour, you can customize the privilieges needed to display some menu items :
    Tools menu : The items are fully customizable. You can define the privilieges needed to display them.
    Process Model : The "Enabled expressions" of the configuration and execution entry points are customizable. (->Sequence properties, "Model" tab)
    3/ Finally you can customize the operator interface to choose the menu items to display. (Look at "TestStand Reference Manual", chapter 9)
    But before you try to customize TestStand, try to explain your needs : The Operator Interface already  updates the menu items depending on the user profile.
    And an operator user has already limited menu options.
    If you need to define  more limited options, the easiest way is to customize the user privilieges of the "operator" profile.
    Bruno

  • The App Store doesn't show me about featured and top charts

    The App Store doesn't show me about featured and top charts

    Thanks Demo.  i had turned on restrictions but I had totally forgotten about it.  I think I had turned it on more just to see what it was, and I had never seen any app be restricted from downloading big before.  I would have never figured this out as there is absolutely no indication in the App Store as to why the button is missing.  Thanks!!

  • Outlook mac Doesn't show the Meeting organizer's full detail as in contact when you hover over

    In the out look , when you received an meeting request, we can see the organizer's email address, but when you hover over the email address it says "presence unknown" and didn't show any details of that email user.
    But i can see the contact search is in All Folder. when its in all folder  it doesn't show his contact. but when i change the search to default GAL LDAP i can see the mail user's details in the contact.
    I hope if i can change the " contact search to Default globla address list LDAP " when you hover over we can see the email user's detail.. But i have no idea how to change the defaut Contact search to another one frm ALl Folder .
    Help me to change this.
    Thanks
    saththiyan

    I have this problem in all the MacBooks... Pro, Air, Ect Ect..

  • Error -17501 flxCVIadp.​dll when starting CVI full featured user interface on Windows 7

    We see the following error dialog when we launch the CVI full-featured user interface (TestExec.exe):
    "Error:
    Unable to load test environment adapter 'flxCVIadp.dll'. Run setup to re-install or remove this adapter.
    Could not connect to TSAutoMgr.exe server. DCOM permissions might be incorrect because of configuration changes for remote execution.  To fix this issue, ensure that the current user is in the default DCOM access permissions or that no users are in the access permissions section of the dcomcnfg.exe dialog box.  You can use the dcomcnfg.exe program, located in the Windows System directory, to change DCOM access permissions.
    Error code: -17501, Unexpected Operating System Error." 
    When this error happens, we can't run any calls to CVI code from within the User Interface.
    We are running Windows 7.  We don't see the error if we run TestExec.exe from the default location:
    C:\Users\Public\Documents\National Instruments\TestStand 2013\UserInterfaces\Full-Featured\CVI
    We get the error message if we copy the CVI directory to somewhere else on the C:\ drive (C:\MyUserInterface for example).  The error happens when we run TestExec.exe directly, but it does not happen if we are already running Labwindows/CVI and we launch TestExec.exe from CVI.
    We are seeing this error with both TestStand 4.2.1 and TestStand 2013 running on different PCs.  This error happens on Windows 7, but not Windows XP.  Though we get the same error with our custom user interface, we see the same error with the stock CVI full-features user interface provided by NI.
    Any ideas about why we can run this from the TestStand directories, but not any directory on our C:\ drive?
    Thanks,
    Peter

    Hi Peter,
    Based on the error messages it looks like this might be a Windows 7 security issue, which would be why it doesn't occur on XP since security is handled differently in that OS. Have you gone into dcomcnfg.exe and checked the DCOM permissions as described in the error message?

  • VI seen as not executable from LV runtime, but only in Full-Featured UI

    Hi,
    I have a very strange situation that one of my VIs is claimed by TestStand as broken but only in Full-Featured UI with LV Runtime.
    - SeqEditor runs it fine both in LV Development and LV Runtime 
    - Simple UI does the same (Program Files\National Instruments\TestStand 4.0\UserInterfaces\NI\Simple\LabVIEW\TestExec.exe)
    - Full-Featured UI runs fine in development but shows Error -18002 in Runtime (Program Files\National Instruments\TestStand 4.0\UserInterfaces\NI\Full-Featured\LabVIEW\TestExec.exe)
    This is even more weird that in our UI what created from Full-Featured this vi works fine in LV Runtime.
    The vi does reading of .ini file from the disk. If it runs correctly and can not find the .ini it shows the selection dialog. I've created the dummy sequence Read INI.seq for this vi and copied its hierarchy.
    I'm using LV 8.6 and TS 4.0
    Message Edited by skof on 07-09-2009 12:24 PM
    Sergey Kolbunov
    CLA, CTD
    Attachments:
    Read INI example.zip ‏218 KB
    error 18002.PNG ‏18 KB

    "Besides that, the error message text looks different in case of "same name" issue, something like:
    Error
    Message: Unable to load VI 'D:\<...>\Log
    Object_LogEventByReference.vi'. LabVIEW already has the VI
    'D:\<...>\ZCAT.exe\Log Object_LogEventByReference.vi' loaded and
    cannot load different VIs with the same name. [Error Code: -18002]"
    Is this your error message?  If so then it is definitely the fact that you are trying to load two VIs with the same name.  Have you changed the Full-Feature UI. Could it be another VI in your sequence?  
    it looks like you have a VI named Log Object_LogEventByReference.vi somewhere. 
    I tried your example but I don't think I did it right.  When I get back to work Monday I'll give it another peak.
    Regards,
    jigg
    CTA, CLA
    teststandhelp.com
    ~Will work for kudos and/or BBQ~

  • Labwindows CVI Full featured OI fails to start

    I've done a deployment installer for Teststand-2013. On one Target PC( Windows 7 64 bit)  it works fine. But on another target PC starting the Labwindows/CVI Full featured OI fails to start ( screenshot attached) with an Error -145 when trying to load testexec.uir . Both targets  have Windows7 64 bit and Office 2010 installed. How can I find out which Active-X control is missing/damaged on the second PC ?
    I've allready found http://digital.ni.com/public.nsf/allkb/9894BE2B832B7FDE86256ECD00041172. But Office is installed and the ActiveX Control Pad is deprecated and incompatible to Windows7 64Bit and no longer available from MS. 
    Solved!
    Go to Solution.
    Attachments:
    Fehler Teststand.png ‏31 KB

    There are no custom commands. It is launching the Operator Interface after the panel  with the checkbox, where you decide if you want to activate now.  We choose to activate later there.  And it also launches the OI when uninstalling.
     I'am attaching the .tsd file, we are using.  This installer should only include stuff , which is common to all teststations like the OI and Teststand Public. So it doesn't include sequences and other files, which are specific to one teststation. 
    Attachments:
    testand2013.zip ‏25 KB

  • How to get and install a full feature HP driver for CM1312 MFP series for Mac OS v10.8?

    Hi there,
    I am running a Mac OS X v10.8 (in Portuguese) and trying to use a HP CM1312 FMP printer, with full features (double-side printing). In the meantime, I have also downloaded the latest driver/firmware from HP but it does not detect the printer. On the other hand, the printer works fine (except for the full feature part)...
    In addition, when I go on the system preferences, there is no option for the printer "driver". Just the other 2 ones...
    Anyone can help? It would be really good to have the printer fully working with my Mac!
    Thanks in advance

    Hi and here is the first round of thanks!
    So, I have:
    Downloaded the Apple driver
    Reset the printer on the system preferences > printers & scan / fax
    Chosen to install the printer
    The system has automatically chosen the "driver" for the printer (HP Laserjet CM1312 MFP)
    Have confirmed and installed
    Now it shows the possibility of a "manual duplex" (double-sided) and it allows it to be chosen. Though, it doesn't print that way but rather the normal way: 1 side / 1 page... On the other hand, the option "driver" is still not available on the system preferences > print & scan / fax > options & supplies. This probably means that it won't allow a double-sided printing... (just a guess)
    Do you have further knowledge?
    Thanks

  • Visual Studio Adding Controls to Full-Featured

    I am trying to modify the Full-Featured GUI - the C++ Using MFC version- in Visual Studio 2010 but nothing I do to the resource file seems to "take".
    I went through and added a TestStand ActiveX Listbox along with a standard button and listbox. While I can see my changes when I test the dialog box (see attached), when I actually run the application (either in VS 2010 or outside of it) it's like I didn't make a change at all (see attached).
    Any ideas as to what's going on here?
    Attachments:
    UI_Running.gif ‏183 KB
    UI_Test_Dialog.gif ‏65 KB

    Nevermind. I got it. 
    I'm used to just placing the controls and running in in older versions of Visual Studio. VS 2010 is new to me so I figured I was doing something wrong. It took me a while to figure out that these GUI samples size/move the controls programatically. 

  • Jabber for Windows 9.2.1 Contact Away status doesn't show duration

    .Jabber for Windows 9.2.1 Contact "Away" status doesn't show duration. I am wondereing if it is possible with Cisco Jabber client. Microsoft OCS client used to show.

    Hi,
    This is currently not supported in Jabber.
    If you think that this feature should be in Jabber, you can open a TAC case and do Enchancment request with them?
    Regards,
    Srdjan

  • I have an Ipad My apple ID and password works for Ibooks and Icloud but when I try to get into the app store it doesn't show my entire email address on the account. When I try to get into the app store it tells me my password is incorrect.  How can I corr

    I have an Ipad My apple ID and password works for Ibooks and Icloud but when I try to get into the app store it doesn't show my entire email address on the account. When I try to get into the app store it tells me my password is incorrect.  How can I correct this? I have been emailing support but so far they have been no help

    Open the App Store app, go to the Featured pane, swipe to the bottom, tap the Apple ID and sign out. Tap again and sign in with the Apple ID of your choosing.

Maybe you are looking for