Three-Phase Power Analyzer, Etc.

Hi All,
I'm not sure if this is the right board for this question, or if I should ask it on one of the hardware boards.  Let me know if I should move it, please.
I need to set up a LabVIEW-based system to monitor the following:
1.  Output from three-phase power analyzer (480VAC, 0-100AAC) - this could involved monitoring formatted power-quality data from a power analyzer OR monitoring voltage and current on all phases, then doing the power quality calcs in LabVIEW
2.  DC output current (0-200ADC) - This needs to be relatively fast (2000 samples/sec), but not very precise (0.1A resolution would be fine).
3.  DC output voltage (0-600VDC) - Again, this needs to be fast but not very precise.  See current specs, above.
4.  CAN bus - I'll be monitoring a CAN bus and processing CAN data, probably using an NI USB-8473.  I have much of the CAN code written already.
Any suggestions on how I should proceed?  Has anyone had good results with specific power analyzers tied into an NI-based system?  What about current probes?  High voltage meters?  Is there any pre-written LabVIEW code for three-phase power analysis?
Many thanks in advance.

diarmaede wrote:
Hi All,
I'm not sure if this is the right board for this question, or if I should ask it on one of the hardware boards.  Let me know if I should move it, please.
I need to set up a LabVIEW-based system to monitor the following:
1.  Output from three-phase power analyzer (480VAC, 0-100AAC) - this could involved monitoring formatted power-quality data from a power analyzer OR monitoring voltage and current on all phases, then doing the power quality calcs in LabVIEW
2.  DC output current (0-200ADC) - This needs to be relatively fast (2000 samples/sec), but not very precise (0.1A resolution would be fine).
3.  DC output voltage (0-600VDC) - Again, this needs to be fast but not very precise.  See current specs, above.
4.  CAN bus - I'll be monitoring a CAN bus and processing CAN data, probably using an NI USB-8473.  I have much of the CAN code written already.
Any suggestions on how I should proceed?  Has anyone had good results with specific power analyzers tied into an NI-based system?  What about current probes?  High voltage meters?  Is there any pre-written LabVIEW code for three-phase power analysis?
Many thanks in advance.
Hmm... I have used a few three phase power analyzers from Voltech, Valhalla, and Yokogawa with LabView.
Right now I would say Yokogawa has my vote. Either the WT230 or (if you got the budget) a WT500. I am currently using both and find the Yokogawa supplied LabView vi's complete and full featured. Since neither of these can measure 100 amps directly you will need to use external current transformers. For best results I recommend buying matching current clamps from Yokogawa when you buy the analyzer Their use is pretty straight forward just enter the scaling factor into the instrument and the readings will be ranged correctly.
DC current and voltage that high will require a current shunt and some scaling for your voltage. Then you could measure it with any decent DAQ device, maybe a cheap as a NI-USB6009. We like to use the Agilent 34970A with a 34901A multiplexer card for this application. The 34970A/34901A is our Engineering Lab workhouse it has the benefit of ISOLATED CHANNELS direct measurement of 300VAC/DC and it can read thermocouples.

Similar Messages

  • Acquiring USB signal from power analyzer

    I have a 6510e power analyzer that I would like to read in Labview. I have connected an RS232 cable from the back of it, through an RS232/USB adapter into a USB port in my laptop. I am having a hard time finding a way to read that USB data in Labview to manipulate it to get the power readings. Any help would be appreciated. Thank you.
    -Tony

    Tsquared80 wrote:
    I have a 6510e power analyzer that I would like to read in Labview. I have connected an RS232 cable from the back of it, through an RS232/USB adapter into a USB port in my laptop. I am having a hard time finding a way to read that USB data in Labview to manipulate it to get the power readings. Any help would be appreciated. Thank you.
    -Tony
    You have not provided the vendor's name, the programming manual, or the code you have been trying.
    Test the commands in the manual with a terminal emulation program such as Hyperterminal, TerraTerm, etc. and then try them with one of serial example programs that come with LabVIEW. Post back with specific problems and include any error codes you get.

  • Three phase Measurament

    Hi everyone,
    I'm trying to measure the phase and the power factor for a three-phase motor. The problemn is that the motor is running with 480V and the SCXI module that I have can only handles until 300Vrms. I'm thinking about using some voltage transformers to step down the voltage and then connect it to the SCXI module. If I do that, will it affect my phase angle and power factor?
    Assuming that this configuration works, how can I find the phase in each wire? Is it possible to run all samples at the same time and then make some comparisson between their plots to measure that?
    Thank you!
    Kenny Caldas
    Solved!
    Go to Solution.

    Just want to emphasise Lynn's point about 480 nominal volts and what you might actually have.
    Get your design and wiring checked by someone certified to do so before connecting.
    Some further points:
    How is the motor being fed?
    a. If fed by a Direct On-Line starter or a Star-Delta starter, there will be a big spike when the contacts open to turn the motor off, or during the star-delta transition.
    b. If fed by a PWM inverter, then the inverter synthesises the AC 50 or 60 Hz wave form by chopping DC very fast, and relying on the motor windings to act as the low pass filter. Good luck trying to instrument that.
    Fault Level: You must have fuses as close to the instrumentation pick-off point as possible. That way, if there is a fault in your wiring the instrumentation fuse pops, and you do not have the full fault current flowing through your instrumentation wiring. Fault current will probably be about 4 times motor start current if the motor is fused correctly, and if it is an induction motor.
    I would use isolation amplifiers on the voltage inputs. That way you can use a simple potential divider on the input to scale to the voltage you want, but make sure that the isolation amplifier has a suitable frequency range.
    So it would go something like:
    Line voltage->Fuse(or other protection device)->Potential divider->Isolation Amplifier->SCXI module.
    IF you sample each channel fast, e.g. 10,000 samples per sec., then the time difference between samples and hence sampling induced phase error will be small.
    Also look at the safety issues with Current Transformers here:
    http://en.wikipedia.org/wiki/Current_transformer

  • Phase power on x58 Plat-SLi and Pro-E

    Quick question on "how much" Phase power do each of these x58 board have (6 , 8 , 10 , etc) .....
    x58 Platinum SLi - ?
    and
    x58 Pro-E - ? 
    I would imagine (or hope) atleast 8 on both .
    Tia

    Quote from: Henry on 27-August-09, 05:19:35
    Is this what you are asking about?
       5-phase DrMOS Power Design and APS(Active Phase Switching)
    Yup , thx !

  • How can I calculate the frequency of a 2-4Hz three phase sine wave in 50msec?

    I want to calculate the frequency of a sine wave using either all three phases or just one, but I want to know the frequency after 50 msec, I don't want to have to wait for a full period.

    I have a mathematically sound suggestion but I do not know how well it will work in application. Most period measurements measure the time between a full period or several periods to eliminate the error introduced by the measuring device. Essentially the device error is made insignificant.
    Mathematically you can do much more but there is a tradeoff between recording less information and knowing (or assuming) some values. For instance, if one knew the amplitude and could calculate the derivative of the signal, one could calculate the frequency. A sine wave can be represented by the function: A sin (BX)=C , where A is the amplitude, B is the frequency, C is the present measured value. If the equation is solved for X, we get: X=(sin^(-1)(C/A))/B. The d
    erivative of the first equation is AB cos(BX)=C. If the equation for X is now substituted into the second equation, we get, AB cos(B (sin^(-1)(C/A))/B)=C. Solving for B we get B=C/(A cos(sin^(-1)(C/A))). Remember, we already know A and C, so we are done.
    Practically every step and assumption in the above argument introduces possible error which will affect the accuracy of the frequency. Unfortunately it is a trade off and that is why at least a whole period needs to be measured to get an accurate frequency.
    Jeremy Braden
    National Instruments

  • Where can i find a Labview driver for the "8990a PEAK POWER ANALYZER" it's not on NI's site.

    where can i find a Labview driver for the "8990a PEAK POWER ANALYZER" it's not on NI's site.
    if there is no driver maybe you can tell me the closest instrument that comes to this one from the list at,
    http://search.ni.com/query.html?lk=1&col=alldocs&nh=500&rf=3&ql=&pw=595&qp=%2BContentType%3AInstrumentDriver+%2BIDNetManufacturer%3A%22Hewlett-Packard%22&qt=peak+power+analyzer&layout=IDNet
    so i could modify and use the driver

    Hello,
    It looks like Agilent/HP makes the 8990A, but I was not able to find a driver for it that we or Agilent has written for this device.
    Since I am not familiar with the 8990A, I cannot recommend which drivers might be similar, but you are pointed in the right direction. Agilent themselves might know more about which models use similar command sets so that you can modify a driver easily.
    Hope this helps.
    Scott B.
    Applications Engineer
    National Instruments

  • How much phases power supply does the 875P Neo FIS2R got ??

    How much phases power supply does the 875P Neo FIS2R got  ?(
    And will it be enough for the Prescott  ?(

    Prescott will be made on a 0.09u process so it should use less power per MHz, I wouldn't worry about that.
    According to what I see it has 6 power regulators which usually means 3 phase.

  • How do you load doc's and power points etc on the IPAD2?

    How do you load doc's,power point, etc on Ipad2?

    You first need one or more apps on the iPad that supports those document types, otherwise you won't have anywhere to store them (except as email attachments) - the iPad is not like a 'normal' computer which has a file system, on the iPad each file/document has to be stored/associated with an app. Once you've decided on the app(s) then, depending on the app, transfer may be done by the file sharing section of the iPad's apps tab on your computer's iTunes, wifi, Dropbox, email attachments etc.
    Documents To Go supports word, excel, and powepoint files :
    'normal' version - http://itunes.apple.com/us/app/documents-to-go-office-suite/id317117961?mt=8
    'premium' version - http://itunes.apple.com/us/app/documents-to-go-premium-office/id317107309?mt=8 (can edit as well as view powerpoint)
    Transfer methods to Documents To Go : http://support.dataviz.com/support.srch?docid=14497&pid=198

  • How to generating three phase sine wave simutiously with Vistual C++?

    Here I want to generate three phase sinewave at the same time with the phase angel 120 continiously. I can creat a task that contain 3 AOs, and generate 3 same sine wave at the same time. But I can not create 3 individual task which contains one AO channel, and write data to FIFO. Please tell me how to realize it?

    Hello, Rilee,
    Thank you very you very much. But I am still confused. The website I can not open. As you said, I shall create a data array to contain three phase data, for example, sinedata[750], sinedata[0:249] contains first AO, and sinedata[250:499] the second, and the rest is the third. then
    1. send the data for sinedata[0] to sinedata[249], to the board. with DAQmxWriteAnalogF64;
    2. send the data for sinedata[250] to sinedata[499], to the board. with DAQmxWriteAnalogF64;
    3. send the data for sinedata[500] to sinedata[749], to the board. with DAQmxWriteAnalogF64;
    and or so.
    Is all the above description right?
    Here I have several questions:
    1. When shall I send second section sample data? I think it shall be all the first data have been written to the board. And How can I know that all the first section data have been sent to the buffer?
    2. If I call DAQmxWriteAnalogF64 to write the second section data to buffer after the have finished first section data written, will this function affects the wave of the first section data?

  • Help is needed to implement a PLL to obtain the angle of a three phase sinusoidal system

    Im trying to develop the PLL to obtain the angle of the three phase system that allows to transform a three phase system into dq axes using Park transformations, there is any example?.
    The voltages are obtained from an analogic module in the FPGA using a cRIO device.

    did you ever solve this problem, i am having issues with this as well

  • 3 or 4 Phase power?

    does anyone know whether they use 3 or 4 phase power on the k8n neo?
    usually they state it in reviews, but i can't seem to find it mentioned at all anywhere.
    can anyone relay anything about this? ta.

    You can try to clear CMOS and try out with another video card.

  • LabVIEW Drivers for Norma 5155 power analyzer

    I have several questions concerning a GPIB LabVIEW driver for the power analyzer NORMA 5155 (NORMA is now part of LEM company):
    1- Has anybody programmed a driver specially for this device so far ?
    2- Is it possible to use other similar drivers (LEM/NORMA 4000..6000) for it?
    3- How would you approach building a suitable driver? (Instrument I-O Assistent ...,)?
    Any answer could be helpful.
    Andreas, Germany

    1) There are no drivers for the 5155 at http://zone.ni.com/idnet97.nsf/browse/
    (but perhaps someone beside NI has programmed a driver)
    2) The same type of instrument from the same company will likely have a similar command set. The drivers for the 4000 and 6000 are Plug and play driver and not IVI drivers, so modifying them would be easy.
    3) I would first call LEM tech support and ask what the difference between the commands sets of the the 5155 and 4000/6000 are. If LEM tech support is unable to give a good answer, then I'd try to get the manuals for the 5155, 4000, and 6000 to just compare the command sets myself. If they are very similar I'd just modify the old driver. If they are very different, I'd just make I/O assistant VI for each function in th
    e manual, and I would have a low-level driver. Once you have this low level driver you can just combine functions to make higher level VIs.
    Hope this helps!

  • Why does my mac pro gets extremly hot about 20 min or so that im on and freezes about a 1 hour that im on then i have to power off etc can u help me pls

    why does my mac pro gets extrwhy does my mac pro gets extremly hot about 20 min or so that im on and freezes about a 1 hour that im on then i have to power off etc can u help me pls

    You can find out what processes are loading your system by running Application Monitor (in Launchpad > Utilities if you're running Lion or Launchpad > Other under Mountain Lion). Select "All Processes". Sort the display by CPU% (click on the label of that column). What processes show over 10% CPU?
    Also, when you click on the CPU button on the lower bar, what shows as your % idle? (Mine is showing about 98% just reading and posting here.)
    If no process is causing the heat, you could have a hardware problem.

  • P67A-GD55 board stuck in "CPU is in 1 phase power mode" loop.

    New build: mobo: as stated, CPU: i5-2500k, Cooler: Cooler Master TX3, PSU: OCZ700SXSP, RAM: 4x2GB PNY DDR3-1600, GPU: EVGA GT440, HDD: WD500AAKX, DVD: LGGH22NS50.  System assembled without a hitch in Cooler Master Centurion 534+ ATX case.
    Moment of truth:  Switch PSU on. System launched into loop of CPU 1 phase power mode = on for fraction of second, off for 1-2 sec.  The indicator is led 1 of 6 lighting briefly with each cycle.  The FP power led lights up and the fans all spin during the brief on periods. Started disconnecting peripherals and power connections, removing ram and at each test there was no change.  Got down to just PSU and mobo with still no change.  Pulled CPU power connector leaving just mobo 24 pin and still no change.  Reseated CPU and switched coolers somewhere in the middle of that. 
    What have I missed that will get this system to boot?

    Last update to this thread, just to say problem completely solved with the replacement mobo from MSI.  This one booted up the way it should and my new system is purring and running quite cool under all default settings.  Have just two 120 mm case fans, one intake and one exhaust, plus TX3 cooler on the i2500k.  MSI software says CPU is running about 29 degees and NZXT sentry 2 fan controller says bottom of heatsink is 23-24, with all temps min the case < 25 and no warm air exhaust.  Must be the relatively mousy GPU (EVGA GT440) not cooking everything in the neighborhood.
    I didn't build this for gaming, just for running a very large number of browser, Excel, Windows Explorer et al windows at the same time without hanging.  It's doing that now under W7 Pro 64bit.   to MSI for backing up their warranty and   from me when I use the new rig.

  • How to acquire correctly three-phase signals (Problem with the gap between signals)

    Greetings
    I need to analyze three sinusoidal signals 120 degrees out of phase by nature including my version of LabVIEW 7.1 and the acquisition card I used is the Measurement Computing USB 1208FS. In principle the acquisition and display them individually does not represent any kind of inconvenience, the problem arises when I try to observe the three signals in the same waveform graph. At this point to run the test continuously (Continuously RUN) the signals lose their phase shift and this becomes variable along the process of signal acquisition occasionally taking its original phase shift (in Figure 2 shows how to vary the phase angle between the signals), just watch the same channel form using 3 distinct stages and the signal (in theory the same) is outdated fig 4. How can this problem be corrected? There is some appreciable time lag between data collection in the different channels that would alter the correct acquisition of the signals. You can correct varying the sampling frequency (rate) and the count?
      Pd = vi attachment used for the acquisition
    Thanks
    Attachments:
    figure 2.jpg ‏70 KB
    figure 4.jpg ‏72 KB
    3 channel.vi ‏388 KB

    Duplicate Post
    Cory K

Maybe you are looking for

  • HT1657 How do I view my rented movie on itunes

    How do I view my rented movie on itunes

  • How APEX stores CSS files in a database?

    We are trying to locate the tables in a database, where APEX stores the CSS Aplications files? We have lost some important CSS and Java Script files and we have a backup of these files. However we can not locate the table in a database, where we have

  • Communication with third party

    Hi Folks,     I need to communicate between a 3rd party and SAP system through SAP XI as a middleware. If I have the ip adress of the 3rd party how I'm going to connect the third party. If at all I'm able to connect to SAP XI from the 3rd party then

  • Locking iPhone via icloud doesn't work

    I recently lost an iPhone 5. I went on to my iCloud account and locked the handset via the find my iPhone app. I have since discovered that it's of no consequence at all, apparently. My telco informed me that the SIM was replaced and the phone has be

  • Get Internal Server Error when run the site

    the url of my site is : http://webdb.us.colorcon.com:7777/pls/portal30 everything ran fine till yesterday. but i also created 2 new sites as follows :- http://webdb.us.colorcon.com:7777/pls/prtltest http://webdb.us.colorcon.com:7777/pls/prtltran the