Time constraint maintainance error

hi, when I am trying to update the infotype 1002, after maintaining the relation between Position and Org Unit through RH_Relation_Maintain I am getting an error ' time constraint not found for S 1002 A003'.  I do not have the previliges to maintain new entries in T777Z either.
any suggestions on how can I handle this would be helpful.

Hi,
Well, are you trying to do a batch input on infotype 0000? If yes you need to check that the proposed values respects the time constraint, meaning no gap, no overlaps and no inversions. Also fields SUBTY, OBJPS, SPRPS and SEQNR must remain initial when processing IT0000...
Kr,
Manu.

Similar Messages

  • Time Constraint Error when calling a Function module from Webdynpro ABAP

    Any help will be greatly appreciated - Thanks RM
    Time Constraint Error
    Information on where terminated
        Termination occurred in the ABAP program "SAPUP50R" - in
         "CHECK_TIME_CONSTRAINT_S1".
        The main program was "MP000000 ".
        In the source code you have the termination point in line 1069
        of the (Include) program "UP50RU01".
    Error occurred during batch input processing
    Source Code Extract
          l_is_inconsistent = 'X'.
        ENDIF.
      Check if there are inverted time periods.
        IF l_prelp_line-begda > l_prelp_line-endda.
          l_is_inconsistent = 'X'.
        ENDIF.
    Check if there are overlaps or gaps.
        IF NOT l_prelp_before IS INITIAL.
          l_date_difference = l_prelp_line-begda - l_prelp_before-endda.
          IF l_date_difference <> 1.
            l_is_inconsistent = 'X'.
          ENDIF.
        ENDIF.
        l_prelp_before = l_prelp_line.
      ENDLOOP.
      IF l_prelp_before-endda <> '99991231'.
        l_is_inconsistent = 'X'.
      ENDIF.
      IF l_is_inconsistent = 'X'.
        IF p_access_type = 'R'.
    490 Datenbankschiefstand Personalnummer & Infotyp &
          MESSAGE x490 WITH l_prelp_before-pernr l_prelp_before-infty.
        ELSE.
    491 Unzulässige Daten Personalnummer & Infotyp &
    Line 1069 Error occcurs >>>>  MESSAGE x491 WITH l_prelp_before-pernr l_prelp_before-infty.
        ENDIF.
      ENDIF.
    ENDFORM.                    " CHECK_TIME_CONSTRAINT_S1     "XYVN0352581
    *&      Form  clear_no_adapter_needed              new     "XREN844998
          text
    FORM clear_no_adapter_needed .
      CLEAR no_adapter_needed.
    ENDFORM.                    " clear_no_adapter_needed
    *&      Form  set_no_adapter_needed              new     "XREN844998
          text
    FORM set_no_adapter_needed .
      no_adapter_needed = 'X'.
    ENDFORM.                    " clear_no_adapter_needed

    Hi,
    Well, are you trying to do a batch input on infotype 0000? If yes you need to check that the proposed values respects the time constraint, meaning no gap, no overlaps and no inversions. Also fields SUBTY, OBJPS, SPRPS and SEQNR must remain initial when processing IT0000...
    Kr,
    Manu.

  • Time Constraint Error when calling a Function Module

    Any help will be greatly appreciated - Thanks RM
    Time Constraint Error
    Information on where terminated
    Termination occurred in the ABAP program "SAPUP50R" - in
    "CHECK_TIME_CONSTRAINT_S1".
    The main program was "MP000000 ".
    In the source code you have the termination point in line 1069
    of the (Include) program "UP50RU01".
    Error occurred during batch input processing
    Source Code Extract
    l_is_inconsistent = 'X'.
    ENDIF.
    Check if there are inverted time periods.
    IF l_prelp_line-begda > l_prelp_line-endda.
    l_is_inconsistent = 'X'.
    ENDIF.
    Check if there are overlaps or gaps.
    IF NOT l_prelp_before IS INITIAL.
    l_date_difference = l_prelp_line-begda - l_prelp_before-endda.
    IF l_date_difference 1.
    l_is_inconsistent = 'X'.
    ENDIF.
    ENDIF.
    l_prelp_before = l_prelp_line.
    ENDLOOP.
    IF l_prelp_before-endda '99991231'.
    l_is_inconsistent = 'X'.
    ENDIF.
    IF l_is_inconsistent = 'X'.
    IF p_access_type = 'R'.
    490 Datenbankschiefstand Personalnummer & Infotyp &
    MESSAGE x490 WITH l_prelp_before-pernr l_prelp_before-infty.
    ELSE.
    491 Unzulässige Daten Personalnummer & Infotyp &
    Line 1069 Error occcurs >>>> MESSAGE x491 WITH l_prelp_before-pernr l_prelp_before-infty.
    ENDIF.
    ENDIF.
    ENDFORM. " CHECK_TIME_CONSTRAINT_S1 "XYVN0352581
    *& Form clear_no_adapter_needed new "XREN844998
    text
    FORM clear_no_adapter_needed .
    CLEAR no_adapter_needed.
    ENDFORM. " clear_no_adapter_needed
    *& Form set_no_adapter_needed new "XREN844998
    text
    FORM set_no_adapter_needed .
    no_adapter_needed = 'X'.
    ENDFORM. " clear_no_adapter_needed

    Hi,
    Well, are you trying to do a batch input on infotype 0000? If yes you need to check that the proposed values respects the time constraint, meaning no gap, no overlaps and no inversions. Also fields SUBTY, OBJPS, SPRPS and SEQNR must remain initial when processing IT0000...
    Kr,
    Manu.

  • How to slove the time constraint error?

    Hi Experts,
    Please help me solving the error " Grouping not possible for infotype 0077  time constraint 3 I '".
    I am getting this error when i click on check and send button. Please help me in solving this on.
    Thanks,
    Rocky.

    Hi,
    I solved a similar problem by changing the configuring Personnel Management->Personnel Administration->Basic Settings->Basic Settings for Concurrent Employment->Editor for Personnel Assignment Groupings->Change Assignment of Grouping Rules to Grouping Reasons in the img.
    Hope it helps.

  • IT2001 error, no time constraint reachion for infotype 2001 with tm const00

    Dear Seriors,
    When I try to add any absence, it show the below given error message (red colour), but if I hit the enter button it allows me to mark absence.
    no time constraint reachion for infotype 2001 with time constraint class 001
    What might be the reason?
    Regards
    ET

    The time constraint class is used to check for collisions between Time Management infotypes (2001 to 2012). It allows you to specify different regulations for checking for collisions between individual subtypes.
    The views Time Constraint Reaction to Time Management Infotypes (V_554Y_B) and Global Time Constraint Reaction (V_T554Y) contain rules for the collision check.
    Please explore on this.

  • Time constraint not found for A1001 B007

    Hi all,
    I have created a role and assigned users to the role and created a workcenter in Po01. While assigning the workcenter to the role, its giving a error "Time constraint not found for A1001 B007". I have checked the start date of workcenter is greater than the start date of the role. Please let me know, any config. needs to be done.

    Hi!
    Check in table T777Z in SM30 or SM31, you will see the time constraint for B007 has not maintained
    Simply add new entry and fix it. Then you can get rid of this error!
    Regards!

  • Time constraint 'T' for custom infotype

    HI experts,
    Im creating a custom infotype and i want to assign time constraint 'T' for that infotype. But while assigning the time constraint in Infotype characteristcs in PM01, it throws the below error message.
    "TIme constraint T is not allowed for 9021 infotype".
    Pls tell me what is the pbm here and how to solve the problem?

    Hi,
    Try this.
    If a subtype needs to be maintained for the Infotype then some additional steps also needs to be performed
    before providing Infotype characteristics
    1. Select the Technical attributes from the initial screen of PM01 transaction .You will see a list of RP_XXXX where XXXX is infotype.
    2. Select the change button on application tool bar. The dialog module in the above screen then becomes
    editable.
    3. Select the Infotype 9021 and select the details button. Make sure you are in change mode.
    4. Provide the Subtype field of the Infotype, Subtype table as T591A and Subty.text table as T591S.
    5. Save and go back to the initial PM01 screen.
    6. The subtypes for an Infotype can be entered via the maintenance view V_T591A.
    Now try maintaining time constraint T with view V_T582A through SM31.
    cheers
    Ajay

  • No Time constraint for S 1001

    Dear Team,
    When I am trying to create a relationship to Position (S) or (C) Job, receiving a message as "There is no time constraint for S 1001". Unable to locate the exact error location in the customization.
    Could anyone know how to solve this. Not maintained any new objects or relationships.
    Thanks and Regards
    Team Member.

    Hi,
    Should have been standard for Position (S) and Job (C), but check table V_T777ZIT for IT1001 that the time constraint entry exists for the exact relationship you are trying to create.  If it does not exist, you will have to create the time constraint for that object and relationship. 
    IMG:  Personnel Management --> Organizational Management --> Basic Settings --> Data Model Enhancement --> Maintain Infotypes.  Select IT1001 and click on the folder on the left for Time Constraint.   Only one relationship at a time (Position described by one Job) - time constraint = 2.  More than one relationship at a time (Job describes many Positions) - time constraint = 3.
    Paul

  • Position Holder relationship Time Constraint

    I have received a unique requirement from my client.  They want only one employee to hold one position and on position only to be held by one employee.  This in itself is the easy part. 
    However, for contingent workers (non-employees) that want to be able to tie multiple people to one position.
    Has anyone ever done this?  If so, how?
    Any additional information that anyone can provide would be much appreciated!

    Hi - You stated the following  - see my notes in Bold:
    You can either turn off the '100%' check for all Positions or make it a Warning or Information instead of an Error. This affects all Positions.  - Not an option as this should throw an error for employees.
    Personnel Management > Organizational Management > Basic Settings > Relationship Maintenance > Maintain Relationships
    Click on Holder (008) > click on 'Relationship Characteristics' > W - Warning or I - Information
    You can also Change the time constraint for the Position to Person A008 part of the relationship.  Also, not an option as we want employee positions to error - only for non-employee positions should this be allowed.
    Personnel Management > Organizational Management > Basic Settings > Relationship Maintenance > Maintain Relationships
    Click on Holder (008) > click on 'Time constraints' > Click on 'A008' > Choose '3'
    You can also, set the 'Staffing' Percentage' on the Relationship Infotype - A008 - holder to a blank.

  • No time constraint reaction for infotype 2005 with time contraint class 00u2019

    Hi,
    We have a incident wherein employee is trying to put overtime, IT 2005 for the period when he is on standby IT 2004. It gives error u2018No time constraint reaction for infotype 2005 with time contraint class 00u2019.
    Can anybody help?

    Hi,
    Please maintain table V_554Y_B for 2005 TC class 00 and 2004 infotype.
    Regards,
    Dilek

  • Retention Period Not maintained Error when Archiving

    Dear Experts,
    i am trying to Archive the Archiving Object(MM_EKKO) but i have got the error below
    "Retention Period Not maintained" Error
    i tried to read different forums on this issue but am not sure i understand why this error happens.
    i appreciate your fast response!
    best regards

    Hai,
    In SPRO - IMG - MM - Purchasing - Define tolerance limit for archiving. In this maintain the residence time 1 & residence time 2 for the Purchasinh doc type & also with item category also.
    Define Tolerance Limit for Archiving
    In this step, you specify how long external purchasing documents are retained unchanged in the database before being archived.
    You can define two time periods, via which you control the archiving of the documents:
    Residence time 1 for items without a deletion indicator
    Before the deletion indicator is set for a document item, the system checks when the relevant item was last changed. In the process, a change in the PO quantity is taken into account in just the same way as a goods receipt, for example.
    The date of the last change is compared with the current date. If no change has been made within the residence time 1 entered , the deletion indicator is set for the item.
    Residence time 2 for items with a deletion indicator
    For document items for which the deletion indicator was set manually or during the archiving run, the system checks how many days have elapsed since the deletion indicator was set.
    The whole document is only archived if:
    The deletion indicator has been set for all items of the document
    None of the items have been changed during the residence time 2 entered - i.e. the last change is the setting of the deletion
    The archived documents are then deleted from the database.

  • Any report to identify Time Constraint issues?

    Hello,
    Is there a report that I can run to get the employees and Infotype records with time constraint issues? So until last week, we had not turned on the PC-UI switch in T77S0 table. So the way it worked was, if in history there were 2 records with time gaps for Infotype with time constraint = 1, then it still allowed us to create new records. Now with the switch turned on, it gives an error. Once the historic records are corrected, it allows us to proceed. This is freaking out a lot of data specialists, and we were wondering if we can proactively identify the employees with these historic data inconsistencies and be able to correct them. Please let me know.
    Thanks,
    Nakul

    Found it: RPUSCNTC
    Thanks,
    Nakul

  • Deleting an Infotype with Time Constraint 1 - programatically

    Hi there,
    We have a few records (IT0008), that need to be deleted. Unfortunately, when we use PA30 to delete, it won't delete the record(s). (Displays the error msg. "Record has time constraint 1" ) But, when we use the Utilities option in PA30 and go thru', it appears to successfully delete the same.
    Now, could somebody pl. let us know how to go abt. doing the same programatically in ABAP ? I've tried looking at the FM's HR_MAINTAIN_MASTERDATA and HR_INFOTYPE_OPERATION (without much luck though....Although, SAP claims to have a documentation of these FM's, there is actually no proper docmn. at the Field level of these FMs)
    Moreover, the FM HR_MAINTAIN_MASTERDATA returns exactly the same error "Record has time constraint 1".
    Am a bit baffled as it is...
    Any help would be gratefully acknowledged and appreciated.
    Many thanks in anticipation,
    Kind Regards,
    RVS

    there is no function module to do forbidden actions.
    you only can do it with DELETE statement.
    select single dbtab from t777d into gv_dbtab where infty = p_infty.
    delete from (gv_dbtab) where pernr in p_pernr.
    But you will have to be very carefully. There are "blind" infotypes behind some "normal" infotypes you will have to care about (i.e. 0000 -> 0302).

  • Time Constraints on ESS - Record Working Time and Leave Request

    Hi All,
    I have configured Time Constraints and their reaction in V_T554Y.
    When I record the appropriate combination of Attendances and Absences in back-end, I can see the reactions as specified... However, when I try to do the same in ESS - Recording Working Time and Leave Request, I do not see that Time Constraints taking effect on the front end.
    Here is what I have done:
    I have two attendance - P001 and P002. P001 is configured to be recorded on Leave Request where as P002 is configured to be recorded via Record Working Time (CATS) link.
    I record the attendance P001 in Leave Request and also post that into infotypes. After this, I try to record P002 in the Record Working Time Screen and I still get errors (Errors are from: HRTIM00REC E/207 and LR E/335)
    If I try to replicate the same in the back-end in IT20002, then there is no issues.
    Can anyone help and let me know how we can implement the same Time constraints reactions on the front-end and the back-end.
    Thanks a bunch
    - Harshal

    Note that Time constraints are not valid for Leave request and Working time ie in ESS
    it only comes via PA30
    in CATS too, we dont follow much HR related collisions checks these are taken into consideration during CAT6
    and in leave request via Rptarqpost
    so its not gonna work, Its intended and correct! go for a user exit cats0003 or check cac1 profile customisation

  • Time constraint of time Infotype 2006

    Hi all,
    I have a requirement wherein In IT2006 same record should not be created on the same date. For eg. if I create a record in IT2006 for its subtype "Leave Encashable" on 01.04.2014 and again I am creating it on 01.04.2014, It is not restricting me to do so. It is accepting and creating the same record.
    I checked the settings in table V_t544y and V_544y_b, but I am not able to find out where actually I need to make changes.
    Looking forward for a reply.
    Tnx
    Megha

    Check in table V_T582A. Currently it might be maintained as Z. See the below options:
    1
    Record must have no gaps, no overlappings                  
    2
    Record may include gaps, no overlappings                   
    3
    Record may include gaps, can exist more than once          
    A
    Infotype exists just once from Jan.1 1800 to Dec.12 9999   
    B
    IT exists for maximum of once from Jan.1 1800 to Dec.12 9999
    T
    Time constraint is based on subtype or subtype table       
    Z
    Time constraint for time management infotypes -> T554Y     
    But this is SAP Standard Infotype, and making any changes in Standard Infotype is not advisable.
    Thanks and Regards,
    Bhagyashree

Maybe you are looking for

  • Best Practices for Integrating UC-5x0's with SBS 2003/8?

    Almost all of Cisco's SBCS market is the small and medium business space.  Most, if not all of these SMB's have a Microsoft Small Business Server 2003 or 2008. It will be critical, In order for Cisco to be considered as a purchase option, that the UC

  • ISE Using my device Portal , devices still in pending registration status

    Abstract: I'm on ISE 1.2 patch 8. We want give access wireless to devices mobile using 802.1x with Active Directory. The condition is that he previously the user must register mobile device in "my device portal" -The corporate user connected from the

  • How can I use the Locu Menu Widget in Adobe Muse?

    I am trying to use the Locu Short Code in Adobe Muse but each time I use the following short code it crashes the entire site/program. Can someone let me know what additional div's or code I can use to insert this code into my website? <script id="-lo

  • Lumia series and antenna problems - true?

    Hello Just found a very odd recently made study of mobile phones antenna performance. It seems to be serious science, but the results are most definitely not in Lumia's favor. Actually Lumia 925 is rated as the phone with the worst results - which se

  • Editor has stopped working: how do I restore it?

    Up until this morning, SQL Developer was working fine, I'm quite pleased with it overall. This morning, however, I fired it up and opened a query window and discovered that the backspace, delete, enter and arrow keys no longer work. The only thing I