Time Delay Express VI default to show as icon?

I am really only intrested in the Time Delay "express vi"
This is the only express vi I ever use and it drives me nuts everytime I drop it in and this HUGE box takes up space for nothing.
I would really love to have just the one VI able to default to Show as icon.
Attachments:
Time.png ‏32 KB

Part of me says that Express VIs should be as annoying as possible so they go away.  But, in the spirit of trying to be helpful I will offer one suggestion.  I have created a subVI which only contains the time delay Express VI.  You can add this to the Palette (ie. user.lib) and go to Tools->Advanced->Edit Palette Set find the SubVI, right-click and select Place VI contents.  Now when you choose this version it will drop in as an icon.
Attachments:
TimeDelay.vi ‏19 KB

Similar Messages

  • Using more than one time delay in a thread

    Hello,
         I need to use two non-consecutive time delays in a thread. My thread typically proceeds as follows:
    1. Tell an oriel MS257 to change wavelengths
    2. Time delay #1 to give the MS257 time to change
    3. Tell HP 4156C to start sweeping
    4. Poll the 4156C until sweeping is complete
    5. Time delay #2 to give 4156C time to load data
    6. Read/parse/save data
    My problem is that the second time delay seems to start counting immediately after the first one - it does not wait for the sweeping to complete before counting. My VI is attached. It's a bit messy - organizational tips are also welcome!
    Thanks,
    Ying 
    Solved!
    Go to Solution.
    Attachments:
    TFTmeasure.vi ‏115 KB

    Looking into the sources show: Cleanup is a nice tool (even thought it is far from perfect )
    Well, nevertheless, from the wireworking, it seems alright that the second Time Delay express VI should indeed wait for the loop to finish. Therefore, i am wondering why it is skipped. And the only reasonable explanation: You have an error on the error cluster.
    So please debug into it using highlight/probes on the error cluster to make sure that you are not running into issues here.
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Firefox 4 on Windows 7, Tools- Options- General- Startup- When FireFox Starts: Show my windows & Tabs from last time .. but on startup permanently shows only Firefox Default Home page

    Settings (Firefox 4 on Windows 7), Tools->Options->General->Startup->When FireFox Starts: Show my windows & Tabs from last time ..
    On startup permanently shows only Firefox Default Home page

    Make sure that you do not use [[Clear Recent History]] to clear the "Browsing History" if Firefox is closed.
    See also:
    * http://kb.mozillazine.org/Session_Restore

  • Time delay on seeing the changed data onto the webi reports

    Hello,
    I'm new to BOBJ and was hoping someone can help me with adjusting the time delay the reflects the changed data to the Webi reports.
    I have a user that would update a form on our EP.  Afterward, she would have to wait a while before she can see the changed data on our Webi reports.
    can you please tell me the default time lag and show me where I can change it if required?
    thanks.

    Thanks for the reply.
    Our BO is 3.1 SP4.
    We just implemented PBF (Public Budget Formulation) and our forms are running on NWCE server.  It's being written to our backend BW 7.01 SP8 server.  I was told by our users that after she updates some new information on the form, it takes a while before she can see it on the reports.  My understanding was the universe should see the updated data from our BW immediately after they refresh.  Just as you both mentioned.  But according to the users, its not.  there's a time delay.
    I'm going to test this myself if there's a delay.  In the meantime and suggestion would be helpful.

  • Elapsed Time delay only works once in state machine

    Hello.  I'm having problems using the elapsed time delay to show the seconds remaining on a wait step in a simple state machine.  I would like to have a front panel count down showing the time left for the step.  I thought the elapsed time delay was the way to do this.  The problem is the vi runs correctly the first time through.  But then after that the timing does not seem to reset back to the times I had set.  If I remove the elapsed time delay and just stick a wait time in the state, the vi runs as I would expect.  This just doesn't give the user an idea of the time remaining.  What am I missing when using the elapsed time delay, or is this just the wrong tool for the job?
    A smaller issue is that I would like to move the tasks, in this case the LED's outside the loop so I don't have to repeat code.  But when I tried moving them outside with only leaving the constants inside the state they did not work as I expected.  If you have tasks like the operation of a set of booleans that you are used in several states, what is the cleanest way to do this without repeating code?
    Thanks for the help.
    Danny
    Solved!
    Go to Solution.
    Attachments:
    Elapsed Time Delay.vi ‏39 KB

    The problem is that the Auto Reset on the express VI resets the start time of the timer as soon as the time has completed.  So you are essentially restarting the #1 timer immediately and then go on to #2.  Once #2 is completed, #1 has already passed 10 seconds as well.
    What you need to do is use the reset input for the express VI, but only have that be true the first time it is called.  By using a shift register and the implies function on those loops, you can do that.
    As for the duplication of states, don't have a state 1 and a state 2.  Just have a Run state.  Use a shift register to maintain a value for what your next state will be and a case structure to based on that to show what booleans should be lit and what the next state will be.
    Message Edited by Ravens Fan on 06-12-2009 10:56 AM
    Attachments:
    Example_VI_BD.png ‏2 KB

  • Hi Team, Showing Yellow icons after every 15 to 20 Min and internet stop working.when we enable- disbale the network connection then will internet start working fine.Some time network connection is disable but when we renable that connection it will st

    Hi Team,
    Showing Yellow icons after every 15 to 20 Min and internet stop working.when we enable- disbale the network connection then will internet start working fine.Some time network connection is disable but when we renable that connection it will stuck on enabling
    and will not renable till i am not restart that machine. I have 350 Machine in network but facing this issue in 25 machines. Kindly help me on this issue .
    Regards
    Sahil bhateja

    Hi,
    So switch a LAN card fix this issue...seems a compatibility issue or maybe some packs or programs you installed recently cause this issue.
    Have you manually check the network adapter driver from the PC's manufacture website? sometimes, it will be a time delay before Microsoft push out the driver update.
    Check if issue exists in safemode with network, this mode will launch Windows with limited sets of files and drivers. 
    if you have a restore point, restore the pc to a previous point at which the pc is functioning fine.
    Yolanda Zhu
    TechNet Community Support

  • My recirculating pump in sub vi simulation link doesnt work in the second iteration .It opens for maybe half a second whereas i gave the time delay for 5 secs..plz help very urgent

    Hi,
         I have attached my simulation loop.In the model attached i hav eone main pump with constant rpm which drives the 5 smaller pumps and fills the tank at the same time.As soon as the tanks reach their 90% level,the valves of the five pumps close(SP1,SP2,SP3,Sp4,Sp5).After that the recirculating pumps opens for 5 secs of the first tank.As soon as the recirculation finishes,the drain valve(SV1) for tank 1 open and the volume goes to interim storage.This happens for all the remaining tanks.
    My simulation works the first time,but when the second time the loop starts,it skips the recirculation pump even though i gave a time delay for 5 secs.Plz help ..I have attached the simulation.
    Thanks,
    Rami
    Attachments:
    Spatial Logic_2_Final.vi ‏223 KB

    Rami,
    I suspect that you have a race condition. The widespread use of local variables frequently leads to race conditions. Your subVI (Spatial Logic Sub_2.vi was not included) so I cannot run the VI. You have no way of knowing whether the subVI or the inner case structure will execute first, because there is no data dependency between them.
    I think a shift register or a few and some dataflow thinking would allow you to eliminate the inner case structure, the local variables, and, probably, most of your problems.
    Some of the SPi are indicators and some are controls. How are they used?
    The last case of the inner loop retursn to Case 1. Would case 0 be better?
    As for the second time through issue, it may be related to the Elapsed time function Auto Reset. From the help file: "Resets the start time to the value in Present (s) when the Express VI reaches the Time Target (s)." If more than 5 seconds elapses between the first time you use this and the next, it will exit immediately on the subsequent calls.
    Lynn

  • DAQ AO to AI time delay

    Hallo,
    I'm working on an academic control project, where I need to read (ni9215) 3 or 4 channels very fast,
    process the data and write them back (ni 9263) via usb-chassis 9172. To check the accuracy and time
    delays I tried a loop from AO to AI (only one channel) and generated a step, saved the timestamp of the
    step and checked, when the step was readed in the written measurement log. I doesn't see andy difference
    in using two VI's to read and to write or combining them in one VI, so I added images of two VI's.
    While comparing the timestamps of the sampled step and the log file, i noticed time delays of about 200ms
    from output to input. So my VI's are times too slow for my control purpose... anybody knows, what to try?
    In this VI I read data with 500hz, 10 samples to read and 10 samples/channel. The read timeout is set to
    default, but if I set it to zero, strange (negative) times are written to the measurement log... I tried
    to change from N samples acquisition to single sample acq, but it didn't speed up the VI.
    Thanks for answering!

    Hi IoInNBlack,
    first of all thank you for posting in this forum.
    I think you should synchronize your input/output operation, otherwise I don´t understand how you can take the timestamps and consider them
    reliable for your evaluation. I suggest you to modify the LV example here attached with timestamps and file I/O to build up your test and see what results you get then. Consider also that  20 ms are necessary for the acquisition of the samples and then you have add the time necessary to manage the file I/O.
    Best regards.
    Andrea P.
    Message Edited by pxchellone on 07-06-2009 09:23 AM
    Attachments:
    Multi-Function-Synch AI-AO.vi ‏35 KB

  • I've tried every online tutorial for timer.delay + experimented... how to make it work in this sitch

    Hey,
    I've read literally every single timer.delay tutorial I could find online, on youtube, the official documentation, tons of posts on this forum, etc. What I am trying to say is I looked everywhere before posting for help.
    I have a timer running. It runs throughout the game. I need to modify the speed of that timer when a player either hits a certain second(won't work, because the timer is already running) or when someone gets a certain score(can't get it to work, because timer is running).... so my question is how do I get timer.delay to work when the timer is running throughout the entire game. I tried to control the delay by when someone gets a point, but that didn't work either. I am using a trace statement so I see the seconds and the timer speed. the code looks something like
    randomvariable = new Timer(2000,8);
    timer.addEventListener(MouseEvent.CLICK, loop);
    timer.start();
    function loop
    // my looping code here
    What I posted is psuedo code.
    Any ideas on how to make the timer go faster without delay, since I can't get delay to work under the circumstances I explained? Or is there a work around that I don't know about? I will try to give back to the forums by answering other questions. Oh, I am running this on the timeline, not in a .as file. Thanks so much for your help!

    That's what I thought. I thought if I set a delay inside the function or in an if statement for the var that  prints out  the timer decrease that it would work. It doesn't. I'm using Adobe AIR for IOS, but I doubt that makes a difference in this case. I write timer.delay=500; that should make the timer go at 500 milliseconds. My trace shows the amount of milliseconds didn't change throughout the application. It is quite bothersome, since everything else works and every guide and the docs say what I am doing should work. Any ideas?
    Thanks.
    Sincerely,
    Ryan Satterfield

  • PSE 7+ Sudden Animation Time Delay problem?

    I've been using Photoshop Elements 7+ for a long time now. And I've been able to make animations with it. Such as can bee seen on this url: http://i47.tinypic.com/35iumww.gif I know how to change the Time/Frame delay settings quite fine. But as of today my time delay hasn't been working. This is quite random considering I haven't done any kind of updating or editing to the program in general. When trying to set the time delay to 0.15 and clicking the preview button, I find that my animation is as at the default number's speed, 2. Upon changing the time delay many different times, from 0 to 10 (the min and the max), the animation's speed still doesn't change.  I'm at the end of my rope with this and none of my PSE educationed associates know what could possibly be wrong. I did download two fonts today, but that's it. So unless someone might be able to figure out what's changed, then I might have to try and re-install the program. Something I don't want to do. I have a visual if that's of any help.
    http://i47.tinypic.com/e9w64k.png
    Also, I am using a Mac.

    Which version are you using now? You can't be using PSE 7 on a mac, because there is no PSE 7 for mac. The frame delay problem exists in the mac versions 6 through 10. You can either upgrade to PSE 11 or use a program like the free giffun from stone.com to assemble the gif and set the frame rate.

  • Time Delay Indicator

    This should be the simplest thing to do, but I'm getting stuck for some reason: I have a time delay running for a user-specified number of seconds, and I want an indicator on the front panel showing how much of this time has elapsed. I thought the "Elapsed Time" VI would be exactly what I was looking for, but I can't seem to get it to do what I want. I've attached my attempt; if you can point out where I'm going wrong, it would be much appreciated.
    Solved!
    Go to Solution.
    Attachments:
    Time Test.vi ‏34 KB

    You don't have a while loop, so your code only runs once.
    Your time delay is running in parallel with the elaspsed time.  So it will delay the execution of the code.
    Get rid of the time delay and put the elapsed time and its indicator in a loop.

  • Time Delay to wait for a solenoid to open

    I have a Shutter that opens fine but I need to wait with some Time Delay before I continue to process some information.
    I am using Labview 7.0 and have a DaqPad-6016.

    It would be helpful to see your code to see exactly what you are doing.
    However, LabVIEW does have several options for waiting. I have attached a screenshot showing some of these. The time delay is especially useful with DAQ because you can wire your task's error wire through the wait. This will cause the delay to explicitly happen in between the execution of VIs.
    -Sal
    Attachments:
    wait.JPG ‏42 KB

  • Time Delay Connector and Chart Question

    Hello,
    I have two problems with the VC 7.1
    First, how can I design a time delay or a refresh function? In VC 7.0 you have the time delay connector to implement this function.
    Second, in VC 7.0 I can click on a chart and start a action to show me the data of this data series. In VC 7.1 I don' t found something like that?
    Regards Tobias Arnold

    the output of the VISA read i got is call read buffer, but it still seems like a number instead of a string?
    Attachments:
    data.png ‏1 KB

  • Estimate time delay during execution

    Hi, everyone.
    Currently, I have a VISA program for reading signals from a GPS receiver. From the program, I want to measure time delay of execution, i.e. time delay between start and end as shown in the jpg. Are there any vi in LabView facilitating this purpose? Thanks a lot.
    Regards,
    yukfai88
    Solved!
    Go to Solution.
    Attachments:
    VISA.vi ‏12 KB
    Estimate delay.jpg ‏54 KB

    See attached VI and below screenshot which shows how to use it in your code. Just one solution...
    Attachments:
    Elapsed time LV80.vi ‏27 KB

  • Expression for default data

    I'm trying to retrieve a file that is in the following format xxxxxxx_xxxxxx.YYYYMMDDHHMISS. I can't retrieve the file with the following sql command in the parameter "Expression for default for data" as
    to_char(sysdate,'YYYYMMDDHHMISS') because my command is looking for a file that is transferred at that exact time, down to the second.  I could pick up the file if it was named xxxxxxx_xxxxxx.YYYYMMDD and I used the command to_char(sysdate,'YYYYMMDD').  I can't use a wait event to pick up the file, because there is no scheduler associated with this server.  When I try to use the wildcard * it cancels with an error and returns the name xxxxxx_xxxxxxx.YYYYMMDD*.
    Do you know a command I could use in the "Expression for default for data" that would pick up the file in the following format: xxxxxxx_xxxxxxx.YYYYMMDDHHMISS.
    Thanks,
    Isaac Bonds

    Hi Isaac,
    Well, the wait event obviously is the easiest, then you have the exact file name available from the event, even hours later still. But this does require a scheduler to be installed on that server indeed.
    Given you do not use an event, how do you trigger this job now ? Do you use a polling mechanism ?
    And what about the other side that is creating the file: can they send you an event or trigger file containing the actual file name that needs to be processed ?
    Regards,
    Anton Goselink.

Maybe you are looking for