Unspecified error when writing variant shared variable

Hi everybody,
I'm getting an unspecified error (-2147467259) when trying to write a variant to a shared variable hosted on my cRIO device.
I'm using a cRIO chassis as a headless controller that dynamically finds remote ScanIO chassis at startup. Similar to the LabVIEW example, the cRIO finds the chassis and generates clusters containing the IO container refnums as well as other information about the modules. I generate two arrays (local and remote) of these clusters, turn them into a variant, and publish it as a network published shared variable so they can be used in a remote PC to add or remove remote channels as needed.
Has anyone had this sort of issue before? I'm new to real-time so I'm not sure if I have violated some canon here or not Thank you for your help
-Jordan

Jnelson,
There appear to be a few Corrective Action Requests (CARs) associated with using shared variables of the variant data type.  The closest one I could find related to your issue was CAR #291679 where Wiring FieldPoint IO Point into shared variable throws error -2147467259.  All CARs that I could find about using shared variables of the variant type threw the same error you are seeing and are feeding into it less standard datatypes (FieldPoint IO, LVClasses, IMAQ references).
To get a more general overview of your problem, does this error come up the first time you try to write to this shared variable or does it come up somewhat randomly?  It would help if you could tell us exactly what hardware you are doing and if you can recreate this issue by simply deploying a program that writes a constant cluster with the same data types into that shared variable.
A possible workaround for you to try would be using the Flatten to String and Unflatten from String functions and pass that through a string shared variable.  This has seemed to work for others in the past.
Matt J
Professional Googler and Kudo Addict
National Instruments

Similar Messages

  • Errors when writing metadata to files on Windows Server

    Good day!
    I have an iMac running OSX 10.9 (Maverick) and Lightroom 5.2.
    My catalog is on the local iMac drive, and the images are on SMB shared drive (handled by Windows 2012 server).
    I decided to do the final layout of my album using InDesign, and for that I needed to access to images using Bridge. So selected all the images (the rated once...) and issue a Metadata/Save command.
    The system came back with errors on many of the files (such as Photos are read only, and unknown errors).
    Retrying to save the metadata on image that was flagged with an error usually (but not always) worked.
    I tried to select save the metadata for few (6) images in a time, many times it was ok, but sometimes, one or two of them failed (and retrying again usually solved the problem).
    It looks to me like a timing related issue.
    Any ideas?
    (After spending about an hour on this, I have exported the images to my local drive...). In general I don't have similar problems with other apps.
    Any ideas?
    Yuval

    I Yuval
    I'm experiencing more or less the same behavior (see Read-only error when writing metadata to file over network (Synology DS1315+ using AFP) ). For me however, the problem is more pronounced if I use the AFP protocol and is better (I think as you described) if I use SMB (all done on a Synology DS1315+). With SMB it most often works but in very rare cases I also get the "read only" message!
    Do you have solution to this? Or are you stuck as I am?
    Cheers, Chris

  • Error when Writing Metadata to Files in Bridge (Mac) but not in Bridge (PC)

    We get an error when writing metadata to files in Bridge (Mac) but not in Bridge (PC). In the same drive and folder, the PC can successfully write a keyword to a file on the PC, where the Mac returns an error. I have researched this at the Adobe Knowledgebase, but their answer seemed to indicate it was a global issue, and we don't see that behavior on the PC.
    The client is a Mac of course, and the server volume is a Windows share volume. The Mac is bound to AD, and the domain\username and username formats have both been tried when logging in, but you receive the error in both.
    Any help would be appreciated.
    Thanks!
    Rich Oliver

    Hi, I'm having the same problem using FreeNAS (which uses Samba and Netatalk in the backend), but I tried with both AFP and SMB on Mavericks and Yosemite, I still have the same issue.  I think it might be a timing issue with how lightroom interact with a slower write delay using network shares.  I suggest you also chime into this thread:  Lightroom 5 can't write metadata to DNG files   I really hope this is resolved as this is impacting my productivity as I moved my workflow to my Macbook with a shared NAS.

  • Adobe Media Encoder (Error compiling movie) Unknown error when writing to Isilon OneFS 6.5.5.18

    Adobe Media Encoder (Error compiling movie) Unknown error when writing to Isilon OneFS 6.5.5.18 while using Adobe Premiere Pro.
    Process:         Adobe Premiere Pro CC 2014
    Path: /Applications/Adobe Premiere Pro CC 2014/Adobe Premiere Pro CC 2014.app/Contents/MacOS/Adobe Premiere Pro CC 2014
    Identifier: com.adobe.AdobePremierePro
    Version:         8.1.0 (8.1.0)
    Code Type: X86-64 (Native)
    Parent Process: launchd [2538]
    Responsible:     Adobe Premiere Pro CC 2014
    Date/Time: 2015-01-06 14:04:23.500 -0700
    OS Version:      Mac OS X 10.9.2 (13C64)
    Report Version:  11
    Crashed Thread: 55  Dispatch queue: com.apple.root.default-priority
    Exception Type: EXC_BAD_ACCESS (SIGSEGV)
    Exception Codes: KERN_INVALID_ADDRESS at 0x0000000000000000
    Customer created test export with 777 permissions and set mount parameters to the following:
    mount_nfs -o vers=3,tcp,rdirplus,intr,nolocks,async,rsize=32768,wsize=32768
      -- Original mount options:
         General mount flags: 0x40 async
         NFS parameters: vers=3,tcp,nolocks,rsize=32768,wsize=32768,rdirplus
      -- Current mount parameters:
         General mount flags: 0x4000058 async,nodev,nosuid multilabel
         NFS parameters: vers=3,tcp,port=2049,nomntudp,hard,nointr,noresvport,negnamecache,callumnt,nolocks,quota, rsize=32768,wsize=32768,readahead=16,dsize=32768,rdirplus,nodumbtimr,timeo=10,maxgroups=16 ,acregmin=5,acregmax=60,acdirmin=5,acdirmax=60,nomutejukebox,nonfc,sec=sys
    The pcap shows once the movie is created a lockup call is responded from Isilon with Error: NFS3ERR_NOENT
    478         V3 CREATE Call (Reply In 479), DH: 0xea5f731c/QBRSN-0-0-1.mov Mode: UNCHECKED
    479         V3 CREATE Reply (Call In 478)
    484         V3 LOOKUP Call (Reply In 485), DH: 0xea5f731c/._QBRSN-0-0-1.mov
    485        V3 LOOKUP Reply (Call In 484) Error: NFS3ERR_NOENT
    V3 LOOKUP Reply (Call In ....) Error: NFS3ERR_NOENT  -   This is by design of OneFS, we coalesce files and then flush them out to disk which is why the commit time is accurate but the file is not immediately available. however when an async option is used within the mount options this should be avoided if writing asynchronously to the cluster.  Has anyone else seen this behavior lately? (current workaround is to store locally and transfer to the cluster via Finder)

    That error can happen for many reasons...one of the reasons that I occassionaly get it is because I try exporting a movie to an external drive that has been formated in the old FAT32 instead of the NTSF standard.  FAT32 only allows for file sizes up to 2 gigs.  And as soon as it reaches that...I would get that error.  I don't know if that is why you are getting that error...but it would be easy to check.  1) are you generating a file that is over 2 gigs?  2) is your drive that you are exporting to FAT 32 (just right click the drive in My Computer and select "properties" then just look for what it says next to "file system".

  • Error when writing to interface table for HR

    We recently did a client copy from Production to our User Testing client. User was trying to enter time via transaction CAT2 but received the following message when attempting to save the timesheet:
    "Error when writing to interface table for HR"
    Does anyone have advice on how to resolve this issue?
    Thanks as always!

    Hi,
    We have the same problem.
    We tried to add many records to HR via a job but it result with en error message LR036 (Error when writing to interface table for HR)
    Did you find a solution since your problem appear ?

  • Itunes 9.2.1.5 "Error when writing file C:\program files\apple software....

    Got an error message when installing itues 9.2.1.5 "Error when writing file C:\program files\apple software update\softwareupdate.exe you do not have admin right to read/write the menu." "寫入檔案時發生錯誤 C:\program files\apple software update\softwareupdate.exe 你沒有權限存取目錄"
    There is no "apple software update" folder in my C:\program files\
    I tried to uninstalled all apple related software, restart the computer and reinstall the itunes, I still get this error message.
    It appears that the installation of quicktime was successful.

    After the last update I get "QuickTime was not found" Error I have uninstalled and re-installed itunes 9.2.1.5. several times but the problem persists

  • Error when writing the trace in ST01

    Hi Gurus,
    Good day!
    Please advise on how can I resolve this issue in ST01. I'm getting an error "Error when writing the trace No such file or directory".
    Appreciate your help.
    Cheers,
    Virgilio

    Hi,
    Check this link
    http://help.sap.com/saphelp_nw04/helpdata/EN/ae/ed0ad513d0074e944879f05ef318d5/content.htm
    Regards,
    Renu

  • Error when writing to the Internal Buffer-runtime error during querydisplay

    Hi
              I am working in BW 3.5. I am trying to run a query in BEx Analyzer but I am getting the following Error
    Error when writing in the Internal Buffer see OSS note 156957
    I tried for the note but I am not getting relevant information.
    Please let me know what to do.
    Thanks,
    Padma

    Hi,
    please apply the note 1614788. After note implementation, you need to set parameter RSR_HIER_THRESHOLD_EXPORTDB in table RSADMIN via report SAP_RSADMIN_MAINTAIN in transaction SE38.
    If you set this parameter to value 50.000 for example, all hierarchies with more than 50.000 nodes will be buffered in the database instead of using the export/import buffer.
    To find out the current size of a hierarchy, goto the hierarchy maintenance in transaction RSH1 and copy the hierarchie ID from the header data. With this key you can goto transaction SE16 and select table RSRHIEDIR_OLAP (Field HIEID is the hierarchy ID).
    It should resolved your issue.
    Thanks,
    Venkat

  • Unspecified error when trying to access Control Panel

    I am currently setting up Remote Desktop Services on Server 2012 and I have enabled the policy
    "Prohibit access to Control Panel and PC settings".
    When a user clicks on the Control Panel icon, or anything else that points to Control Panel (Screen Resolution, Personalize) they get the normal error of
    "This operation has been cancelled due to restrcitions in effect on this computer. Please contact your system administrator" which is fine and is expected, but they then get the error,
    "Unspecified error".
    Does anyone know how to fix this?

    Hi Tom,
    Have you enabled the option to display "Personalization" in Group Policy?
    This is because "Personalization" option is linked to Control Panel, so if you prohibit access to control panel, and right click on the desktop select "Personalize", it results in the "Unspecified Error".
    Checkout the below thread on similar discussion,
    http://social.technet.microsoft.com/Forums/windowsserver/en-US/76c3f7aa-9189-461e-be4d-5d8af133b151/windows7-explorerexe-generates-unspecified-error-when-trying-to-access-personalize-in-display?forum=winserverGP
    Regards,
    Gopi
    JiJi
    Technologies

  • I/O Error when writing access Log buffer to file. error number: 28

    Hi,
    Oracle OracleAS Web Cache 10.1.2.3.0, Build 10.1.2.3.0 080201 is writing events like this:
    [alert 13215] I/O Error when writing access Log buffer to file. error number: 28
    I've looked for this alert and i've found this description:
    WXE-13215 I/O Error when writing access Log buffer to file. error number: %d
    Severity: alert
    Cause: I/O error happened when OracleAS Web Cache tried to write to the access log file.
    Action: Check the status of access log file. For example, see if the disk is full
    Anybody knows what "error number: 28" stands for? The logs are sended to other server and it seems that the disk size is ok.
    thanks!

    I tested again...it seems LabVIEW doesn't like the way I wrote the measurement files. I attached a set of VIs (ZIP-file) to give you a clue how it was done. When I try to save and read a file containing just plain DBLs from a 1D-Array (see attached file generating VI) it works perfectly well for large file sizes.
    So there might get something messed up by the way LabVIEW saved the measured data. You'll notice, that I (accidentally) left the "prepend array string size" input of "write to binary file" function unwired which means that the size information will be written as a type of header. Maybe this is the reason that it doesn't work as expected...
    Attachments:
    VibrationMeasurement.zip ‏76 KB
    generate_test_bin_data.vi ‏12 KB

  • Error when fetching into a variable of ROWTYPE

    I came across with a vied error when creating the body of a method.
    Problem:
    I have a Type called Emp_typ and a corresponding table Emp_tab.
    When I create the body of get method it gives the following error msg :
    Compilation errors for PACKAGE BODY CHAMITH.EMP_API
    Error: PLS-00386: type mismatch found at 'EMP_ROW' between FETCH cursor and INTO variables
    Line: 9
    Text: fetch get_emp_rec into emp_row;
    Get Method body :
    function get(id_ number) return emp_tab%rowtype IS
    cursor get_emp_rec IS
    select * from emp_tab;
    emp_row emp_tab%rowtype;
    begin
    open get_emp_rec;
    fetch get_emp_rec into emp_row;
    close get_emp_rec;
    return emp_row;
    end;
    However when I do the same without having a type upon the table emp_tab, it works fine.
    Pls give me a solution for that.
    Thanks,
    Chamith

    Hi,
    Let me know the Oracle Database Version.
    Regards,
    Sailaja

  • Error when using replacement path variable in exception range

    I'm trying produce a check report that produces exception highlighting based on a range determined by the associated characteristic.
    eg.
    For Check 1, highlight cells in red where the associated key figure is between 1 and 999.
    For Check 2, highlight cells in amber where the associated key figure is between -999 and -1.
    Now, I know that the lower and upper limit of an exception can be populated by a formula variable. However, when I create a formula variable that uses a replacement path to fetch the limit values from the associated Check and use that in the exception, the query errors when I try to run it:
    System Error: 'Variable name ( technical name ) does not exist or is incorrectly used 4 New Exception.'
    The error long text suggests that the variable is being used incorrectly, even though it says for Formula variables:
    ... can be used in all cases. Note: Formula variables can have units or be without them. Incorrect use can also arise here since the system always calculates in accordance with the units. Formula variables can also be used to create the upper and lower limits in exceptions.
    In this case, the formula variable does not have units.
    Interestingly, but equally unhelpfully, if a regular constant is used instead of a formula variable for the lower limit, but a formula variable is still used for the upper limit, the error message changes to:
    System error in program SAPLRRI2 and form FAC_VAR_IN_VREP_INSERT-1-
    The query works if the formula variable simply holds a default value, so the problem clearly appears to be with replacement path. If BEx doesn't support replacement path formula variables in exceptions, then aside from the fact that it would be useful if that was stated in the errors, what alternatives, if any, deliver the functionality of exception ranges that change depending on the corresponding characteristic.

    I put in the curly brackets so my formula now reads
    "Total inquiries for " + {CnAttrCat_1.CnAttrCat_1_Description} + ": " + ToText({@InquiryTypeSubtotal})
    Now when I check the formula I get the error message "This field name is not known."
    Alec

  • Error When Prompting for Substitution Variable

    Hi - I'm receiving an error when I try to run the following using the substitution variable - but only when I enter a string; when I enter a numeric value it runs fine.
    DECLARE
        l_SCR_Info            VARCHAR2(50) := '''SCR'||&SCR_NUM||'-'||'''';
    begin
    dbms_output.put_line(l_SCR_Info);
    end;Here is the error I receive when I supply a string value when prompted:
    ORA-06550: line 3, column 52:
    PLS-00201: identifier 'AB' must be declared
    ORA-06550: line 3, column 27:
    PL/SQL: Item ignored
    ORA-06550: line 10, column 22:
    PLS-00320: the declaration of the type of this expression is incomplete or malformed
    ORA-06550: line 10, column 1:
    PL/SQL: Statement ignoredCan anyone shed some light on what I'm missing here?
    Thanks!
    Christine

    Hi,
    It looks like you just want one string there:
    l_SCR_Info            VARCHAR2(50) := '''SCR&SCR_NUM-''';Remeber how substitution variables work: SQL*Plus replaces them with values before sending the code to the back end to be compiled.
    If you give a value like AB for the variable, the code you posted is equivalent to:
         l_SCR_Info            VARCHAR2(50) := '''SCR'|| AB ||'-'||'''';by the time it reaches the compiler. AB is not inside quotes, so the compiler looks for a variable or function called AB.
    If you gave a number:
         l_SCR_Info            VARCHAR2(50) := '''SCR'|| 123 ||'-'||'''';there's no problem; the compile knows what the literal number 123 is.

  • Error when executing query with variables in excel

    When I execute a query in excel, it gives some errors if it has some variables (From Date, To Date etc):
    Error Specify a value for variable From Date
    Error Specify a value for variable To Date
    I need to execute the query and then save a view. I want to do this in excel as I am not able to save a view if I execute in a web browser.

    Hi Sanjeev.
    Of course Excel supports input of variable values.
    What version of BW/BI both backend and frontend are you using?
    Please check if you can execute the query in TA RSRT. You could try to generate the query again here.
    Hope it helps.
    BR
    Stefan

  • Unspecified error when stopping XL Reporter Add On

    Dear Experts,
    When I try to generate a XL report, I get the error
    "Required COM Addin has not been loaded and prohibits MS Excel from running".
    Afterwhich, I go to Program Files > SAP > Addons to run the COMAddin-peruser-something.reg. After running this registry file. still same error.
    Anyway, I also experienced the below error when trying to Stop the XL Reporter Addon:
    "Run-time error '-2147024882 (8007000e)': System Error &H80004005(-2147467259). Unspecified error"
    Does anyone has any ideas on this?
    Much Thanks!
    Warmest Regards,
    Chinho

    Check this link,it may solve ur problem.
    Re: how to install advance layout designer