Use 3 internal table in GUI_Download
Hello expert,
i have 3 internal table: gt_header, gt_body and gt_footer. how can i used all 3 in gui_download fm. here is my sample code:
CALL FUNCTION 'GUI_DOWNLOAD'
EXPORTING
filename = gv_file_name
filetype = 'ASC'
TABLES
data_tab = gt_header.
here i can only pass one internal table.
Help please?
Hi Hassim,
Maybe you can declare another internal table, with all fields is type C and length as you wanted.
Loop those three itabs, append to this new itab. then call this FM download.
regards,
Archer
Similar Messages
-
How to populate field catalogue fields in ALV using dynamic internal table
Hi All,
Please let me know how to populate field catalogue fields in ALV using dynamic internal table.
I have created <dyn_table> using code below.
CALL METHOD cl_alv_table_create=>create_dynamic_table
EXPORTING
it_fieldcatalog = g_t_ifc
it_fieldcatalog = g_t_fieldcat
IMPORTING
ep_table = dy_table.
ASSIGN dy_table->* TO <dyn_table>.
Create dynamic work area and assign to FS
CREATE DATA dy_line LIKE LINE OF <dyn_table>.
ASSIGN dy_line->* TO <dyn_wa>.
Now this <dyn_table> has fields like idoc no.,creation date ,
segment field 1, segment field 2 etc..Now idoc no.,creation date are static fields from table EDIDC. And segment field 1, segment field 2 etc are dynamic fields from table EDSAPPL.
In my ALV report I am getting the final layout properly but I am unable to move values to corresponding fields in the final layout shown.Please let me know how to populate these fields from different tables.
I tried this way but its not working.
SORT g_t_edid4 BY docnum.
LOOP AT g_t_edidc INTO g_r_edidc.
READ TABLE g_t_edid4 into g_r_edid4
WITH KEY docnum = g_r_edidc-docnum
BINARY SEARCH.
IF sy-subrc = 0.
<dyn_wa> = g_r_edid4-sdata.
MOVE-CORRESPONDING g_r_edid4 to <dyn_wa>.
CLEAR g_r_edid4.
ENDIF.
MOVE-CORRESPONDING g_r_edidc to <dyn_wa>.
APPEND <dyn_wa> TO <dyn_table>.You have to assign each field to field symbol and then assign the value to that field symbol and asssign that field symbol to workarea field symbol.
LOOP AT g_t_edidc INTO g_r_edidc.
READ TABLE g_t_edid4 into g_r_edid4
WITH KEY docnum = g_r_edidc-docnum
BINARY SEARCH.
IF sy-subrc = 0.
ASSIGN COMPONENT 'SDATA' OF STRUCTURE <DYN_WA> TO <DYN_FLD>.
<DYN_FLD> = g_r_edid4-sdata.
" <dyn_wa> = g_r_edid4-sdata.
" Assign each fields like this.
" MOVE-CORRESPONDING g_r_edid4 to <dyn_wa>.
CLEAR g_r_edid4.
ENDIF.
" MOVE-CORRESPONDING g_r_edidc to <dyn_wa>.
APPEND <dyn_wa> TO <dyn_table>.
Regards,
Naimesh Patel -
Use of internal table with hearerline in ABAP OO
Hi,
I have a very basic question regarding the use of Internal table with headerline in ABAP OO.
I consider the concept of Internal table with header as one of the most features of ABAP, which is not there in any of the other porgramming languages.
I accept that OO's concept is one of the most powerful and a very good concept. We should also implement OO's concept in ABAP.
But my concern is why in the process of moving to OO's the concept of Internal table with headerline is no more used.
Can any one tell me the main reason for this. Is there any technical reason for this. By this i mean anything to do with memory or effeciency.
Thanx,
SrinivasHi Srinivas,
here is something more which i found about the same
follow this link
https://sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/5ac31178-0701-0010-469a-b4d7fa2721ca
and search for header line.
it says:
Tables with header lines not allowed
Only tables without header lines can be declared in ABAP Objects.
Error message in ABAP Objects if the following syntax is used:
DATA itab TYPE LIKE TABLE OF ... WITH HEADER LINE.
Correct syntax:
DATA: itab TYPE LIKE TABLE OF ... ,
wa LIKE LINE OF itab.
Reason:
It depends on the statement whether the body or header line of a table is accessed. The table name should identify the table uniquely. Programs are easier to read. Tables with header lines do not improve performance.
i hope this will help you.
regards,
Kinshuk
PS mark helpful answers -
How to use an internal table of a calling program in to a called program
Hi Experts,
I am calling a report in another report through SUBMIT .
I want to use the internal table of calling prog into
called prog but problem is i have to do it without exporting to memory id and importing it.
Plz provide me any soln..Check for more information on SUBMIT
[http://www.sapdevelopment.co.uk/reporting/rep_submit.htm] -
BADI cant use an internal table with header line
hi,
In BADI, we cant use an internal table with header line, and I am calling a function module which requires internal table as import parameter, now, the table I am passing is without a header line, So how to solve this problem ?You can use a type and then create an internal table of that type.
types :
begin of t_<example>
*field list
end of t_<example>
data :
gt_<table> type standard table of t_<example>
pass this to the FM -
What are the advantages of using an internal table with workarea
Hi,
can anyone tell me
What are the advantages of using an internal table with workarea
over an internal table with header line?
thnks in adv
regards
nagiHI,
Internal tables are a standard data type object which exists only during the runtime of the program. They are used to perform table calculations on subsets of database tables and for re-organising the contents of database tables according to users need.
http://help.sap.com/saphelp_nw04/helpdata/en/fc/eb35de358411d1829f0000e829fbfe/content.htm
<b>Difference between Work Area and Header Line</b>
While adding or retrieving records to / from internal table we have to keep the record temporarily.
The area where this record is kept is called as work area for the internal table. The area must have the same structure as that of internal table. An internal table consists of a body and an optional header line.
Header line is a implicit work area for the internal table. It depends on how the internal table is declared that the itab will have the header line or not.
e.g.
data: begin of itab occurs 10,
ab type c,
cd type i,
end of itab. " this table will have the header line.
data: wa_itab like itab. " explicit work area for itab
data: itab1 like itab occurs 10. " table is without header line.
The header line is a field string with the same structure as a row of the body, but it can only hold a single row.
It is a buffer used to hold each record before it is added or each record as it is retrieved from the internal table. It is the default work area for the internal table
1) The difference between
whih header line and with out heater line of internal table.
ex:-
a) Data : itab like mara occurs 0 with header line.
b) Data: itab like mara occurs 0.
-While adding or retrieving records to / from internal table we have to keep the record temporarily.
-The area where this record is kept is called as work area for the internal table.
-The area must have the same structure as that of internal table. An internal table consists of a body and an optional header line.
-Header line is a implicit work area for the internal table. It depends on how the internal table is declared that the itab will have the header line or not.
a) Data : itab like mara occurs 0 with header line.
table is with header line
b) Data: itab like mara occurs 0.
table is without header line
2)work area / field string and internal table
which one is prefarable for good performance any why ?
-The header line is a field string with the same structure as a row of the body, but it can only hold a single row , whereas internal table can have more than one record.
In short u can define a workarea of an internal table which means that area must have the same structure as that of internal table and can have one record only.
Example code:
data: begin of itab occurs 10,
ab type c,
cd type i,
end of itab. " this table will have the header line.
data: wa_itab like itab. " explicit work area for itab
data: itab1 like itab occurs 10. " table is without header line.
Regards,
Padmam. -
Create Table Control using Dynamic Internal Table.
Hi,
I have requirement in which I will create a Dynamic Internal Table and then I need to create a Table Control Using that Internal Table. Now this can't be done using Screen Editor as it requires a pre-defined internal table or a DDIC Object.
Please Help.This should be correct answer(I am not author of code below):
REPORT ztablemaintace NO STANDARD PAGE HEADING.
TYPE-POOLS: rsds.
DATA: is_x030l TYPE x030l,
it_dfies TYPE TABLE OF dfies,
is_dfies TYPE dfies,
it_fdiff TYPE TABLE OF field_dif,
is_fdiff TYPE field_dif.
DATA: w_selid TYPE rsdynsel-selid,
it_tables TYPE TABLE OF rsdstabs,
is_tables TYPE rsdstabs,
it_fields TYPE TABLE OF rsdsfields,
it_expr TYPE rsds_texpr,
it_ranges TYPE rsds_trange,
it_where TYPE rsds_twhere,
is_where TYPE rsds_where,
w_active TYPE i.
DATA: it_content TYPE REF TO data,
it_modif TYPE REF TO data,
it_fcat TYPE lvc_t_fcat.
DATA: w_okcode TYPE sy-ucomm.
FIELD-SYMBOLS: <itab> TYPE STANDARD TABLE,
<ntab> TYPE STANDARD TABLE.
* Macros
DEFINE table_error.
message e398(00) with 'Table' p_table &1.
END-OF-DEFINITION.
DEFINE fixed_val.
is_fdiff-fieldname = is_dfies-fieldname.
is_fdiff-fixed_val = &1.
is_fdiff-no_input = 'X'.
append is_fdiff to it_fdiff.
END-OF-DEFINITION.
* Selection screen
SELECTION-SCREEN: BEGIN OF BLOCK b01 WITH FRAME.
PARAMETERS: p_table TYPE tabname OBLIGATORY "table
MEMORY ID dtb
MATCHCODE OBJECT dd_dbtb_16.
SELECTION-SCREEN: BEGIN OF LINE,
PUSHBUTTON 33(20) selopt USER-COMMAND sel,
COMMENT 55(15) selcnt,
END OF LINE.
SELECTION-SCREEN: SKIP.
PARAMETERS: p_rows TYPE i. "rows
SELECTION-SCREEN: END OF BLOCK b01,
SKIP,
BEGIN OF BLOCK b02 WITH FRAME.
PARAMETERS: p_displ TYPE c AS CHECKBOX. "display
SELECTION-SCREEN: END OF BLOCK b02.
* Initialization
INITIALIZATION.
MOVE '@4G@ Filter records' TO selopt.
* PBO
AT SELECTION-SCREEN OUTPUT.
IF w_active IS INITIAL.
CLEAR: selcnt.
ELSE.
WRITE w_active TO selcnt LEFT-JUSTIFIED.
ENDIF.
* PAI
AT SELECTION-SCREEN.
IF p_table NE is_x030l-tabname.
CALL FUNCTION 'DDIF_NAMETAB_GET'
EXPORTING
tabname = p_table
IMPORTING
x030l_wa = is_x030l
TABLES
dfies_tab = it_dfies
EXCEPTIONS
OTHERS = 1.
IF is_x030l IS INITIAL.
table_error 'does not exist or is not active'.
ELSEIF is_x030l-tabtype NE 'T'.
table_error 'is not selectable'.
* ELSEIF is_x030l-align NE 0.
* table_error 'has alignment - cannot continue'.
ENDIF.
* Default values for system fields
REFRESH: it_fdiff.
is_fdiff-tabname = p_table.
LOOP AT it_dfies INTO is_dfies.
IF is_dfies-datatype = 'CLNT'.
fixed_val sy-mandt.
ELSEIF is_dfies-rollname = 'ERDAT'
OR is_dfies-rollname = 'ERSDA'
OR is_dfies-rollname = 'AEDAT'
OR is_dfies-rollname = 'LAEDA'.
fixed_val sy-datum.
ELSEIF is_dfies-rollname = 'ERTIM'
OR is_dfies-rollname = 'AETIM'.
fixed_val sy-uzeit.
ELSEIF is_dfies-rollname = 'ERNAM'
OR is_dfies-rollname = 'AENAM'.
fixed_val sy-uname.
ENDIF.
CALL FUNCTION '/SAPDMC/DATAELEMENT_GET_TEXTS'
EXPORTING
name = is_dfies-rollname
IMPORTING
text_middle = is_dfies-reptext
EXCEPTIONS
not_found = 1
OTHERS = 2.
IF sy-subrc <> 0.
MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
ENDIF.
MODIFY it_dfies FROM is_dfies.
ENDLOOP.
* Prepare free selection on table
REFRESH it_tables.
is_tables-prim_tab = p_table.
APPEND is_tables TO it_tables.
CLEAR: w_selid.
ENDIF.
IF sy-ucomm = 'SEL'.
IF w_selid IS INITIAL.
* Init free selection dialog
CALL FUNCTION 'FREE_SELECTIONS_INIT'
EXPORTING
expressions = it_expr
IMPORTING
selection_id = w_selid
expressions = it_expr
TABLES
tables_tab = it_tables
EXCEPTIONS
OTHERS = 1.
ENDIF.
* Display free selection dialog
CALL FUNCTION 'FREE_SELECTIONS_DIALOG'
EXPORTING
selection_id = w_selid
title = 'Selection'
status = 1
as_window = 'X'
IMPORTING
expressions = it_expr
field_ranges = it_ranges
number_of_active_fields = w_active
TABLES
fields_tab = it_fields
EXCEPTIONS
OTHERS = 1.
ENDIF.
* Start of processing
START-OF-SELECTION.
PERFORM f_create_table USING p_table.
PERFORM f_select_table.
PERFORM f_display_table.
* FORM f_create_table *
FORM f_create_table USING in_tabname.
FIELD-SYMBOLS: <fcat> TYPE lvc_s_fcat.
CALL FUNCTION 'LVC_FIELDCATALOG_MERGE'
EXPORTING
i_structure_name = in_tabname
CHANGING
ct_fieldcat = it_fcat
EXCEPTIONS
OTHERS = 1.
IF sy-subrc = 0.
* Complete field catalog
LOOP AT it_fcat ASSIGNING <fcat>.
<fcat>-tabname = in_tabname.
ENDLOOP.
CALL FUNCTION 'LVC_FIELDCAT_COMPLETE'
CHANGING
ct_fieldcat = it_fcat
EXCEPTIONS
OTHERS = 1.
ELSE.
WRITE: 'Error building field catalog'.
STOP.
ENDIF.
* Create dynamic table for data
CALL METHOD cl_alv_table_create=>create_dynamic_table
EXPORTING
it_fieldcatalog = it_fcat
IMPORTING
ep_table = it_content.
IF sy-subrc = 0.
ASSIGN it_content->* TO <itab>.
ELSE.
WRITE: 'Error creating internal table'.
STOP.
ENDIF.
* Create dynamic table for modif
CALL METHOD cl_alv_table_create=>create_dynamic_table
EXPORTING
it_fieldcatalog = it_fcat
IMPORTING
ep_table = it_modif.
IF sy-subrc = 0.
ASSIGN it_modif->* TO <ntab>.
ELSE.
WRITE: 'Error creating internal table'.
STOP.
ENDIF.
ENDFORM. "f_create_table
* FORM f_select_table *
FORM f_select_table.
IF w_active = 0.
SELECT * FROM (p_table)
INTO CORRESPONDING FIELDS OF TABLE <itab>
UP TO p_rows ROWS.
ELSE.
* Selection with parameters
CALL FUNCTION 'FREE_SELECTIONS_RANGE_2_WHERE'
EXPORTING
field_ranges = it_ranges
IMPORTING
where_clauses = it_where.
READ TABLE it_where INTO is_where WITH KEY tablename = p_table.
SELECT * FROM (p_table)
INTO CORRESPONDING FIELDS OF TABLE <itab>
UP TO p_rows ROWS
WHERE (is_where-where_tab).
ENDIF.
IF sy-dbcnt = 0.
WRITE: 'No record selected'.
STOP.
ENDIF.
ENDFORM. "f_select_table
* FORM f_display_table *
FORM f_display_table.
DATA: l_answer TYPE c,
l_eflag TYPE c.
CLEAR: w_okcode.
REFRESH: <ntab>.
* Display table contents
CALL FUNCTION 'STC1_FULLSCREEN_TABLE_CONTROL'
EXPORTING
header = p_table
tabname = p_table
display_only = p_displ
endless = 'X'
no_button = space
IMPORTING
okcode = w_okcode
TABLES
* nametab = it_dfies
table = <itab>
* fielddif = it_fdiff
modif_table = <ntab>
EXCEPTIONS
OTHERS = 1.
IF sy-subrc = 0.
IF p_displ IS INITIAL AND w_okcode = 'SAVE'.
* Confirm update
CALL FUNCTION 'POPUP_TO_CONFIRM'
EXPORTING
titlebar = p_table
text_question = 'Do you want to update table ?'
default_button = '2'
display_cancel_button = ' '
IMPORTING
answer = l_answer
EXCEPTIONS
OTHERS = 1.
IF l_answer = '1'.
* Apply modifications
IF NOT <ntab>[] IS INITIAL.
PERFORM f_add_system USING space.
MODIFY (p_table) FROM TABLE <ntab>.
IF sy-subrc NE 0.
l_eflag = 'X'.
ENDIF.
ENDIF.
* Apply deletions
IF l_eflag IS INITIAL.
REFRESH: <ntab>.
CALL FUNCTION 'STC1_GET_DATA'
TABLES
deleted_data = <ntab>
EXCEPTIONS
OTHERS = 1.
IF NOT <ntab>[] IS INITIAL.
DELETE (p_table) FROM TABLE <ntab>.
IF sy-subrc NE 0.
ROLLBACK WORK.
l_eflag = 'X'.
ENDIF.
ENDIF.
ENDIF.
* Apply creations
IF l_eflag IS INITIAL.
REFRESH: <ntab>.
CALL FUNCTION 'STC1_GET_DATA'
TABLES
new_data = <ntab>
EXCEPTIONS
OTHERS = 1.
IF NOT <ntab>[] IS INITIAL.
PERFORM f_add_system USING 'X'.
INSERT (p_table) FROM TABLE <ntab>.
IF sy-subrc NE 0.
ROLLBACK WORK.
l_eflag = 'X'.
ENDIF.
ENDIF.
ENDIF.
IF l_eflag IS INITIAL.
COMMIT WORK.
MESSAGE s261(53).
ELSE.
MESSAGE s075(3i).
PERFORM f_select_table.
ENDIF.
ENDIF.
* Display table again
PERFORM f_display_table.
ENDIF.
ENDIF.
ENDFORM. "f_display_table
* FORM f_add_system *
FORM f_add_system USING new TYPE c.
FIELD-SYMBOLS: <irec> TYPE ANY,
<upd> TYPE ANY.
LOOP AT it_fdiff INTO is_fdiff.
READ TABLE it_dfies INTO is_dfies
WITH KEY fieldname = is_fdiff-fieldname.
LOOP AT <ntab> ASSIGNING <irec>.
ASSIGN COMPONENT is_fdiff-fieldname OF STRUCTURE <irec> TO <upd>.
IF is_dfies-datatype = 'CLNT'.
<upd> = sy-mandt.
ELSE.
CASE is_dfies-rollname.
WHEN 'AENAM'.
<upd> = sy-uname.
WHEN 'AEDAT' OR 'LAEDA'.
<upd> = sy-datum.
WHEN 'AETIM'.
<upd> = sy-uzeit.
WHEN OTHERS.
ENDCASE.
ENDIF.
ENDLOOP.
ENDLOOP.
ENDFORM. "f_add_system -
Display ALV GRID Using Dynamic Internal Table
Hi all,
I try to display ALV Grid using Dynamic Internal Table, but when i activate my program, i get an error message "DYN_TABLE" is not type-compatible with formal parameter "IT_OUTTAB". ( DYN_TABLE is my Dynamic Itab).
Anybody can help me how to passing Dynamic Itab into ALV Grid ?? Of ALV Grid only accept static Itab ??
Thanks,Hi Vijay,
It's doesn't work, and make new error "Formal parameter "IT_OUTTAB[]" does not exist. However, the parameter "IT_OUTTAB" has a similar name."
Because the method is:
CALL METHOD <ref. var. to CL_GUI_ALV_GRID>->set_table_for_first_display
EXPORTING
I_BUFFER_ACTIVE = <any type (ANY)>
I_STRUCTURE_NAME = <string of type DD02L-TABNAME>
IS_VARIANT = <structure of type DISVARIANT>
I_SAVE = <var. of type CHAR01>
I_DEFAULT = <var. of type CHAR01>
IS_LAYOUT = <structure of type LVC_S_LAYO>
IS_PRINT = <structure of type LVC_S_PRNT>
IT_SPECIAL_GROUPS = <internal table of type LVC_T_SGRP>
IT_TOOLBAR_EXCLUDING = <internal table of type UI_FUNCTIONS>
IT_HYPERLINK = <internal table of type LVC_T_HYPE>
IT_ALV_GRAPHICS = <internal table of type DTC_T_TC>
CHANGING
IT_OUTTAB = <internal table>
IT_FIELDCATALOG = <internal table of type LVC_T_FCAT>
IT_SORT = <internal table of type LVC_T_SORT>
IT_FILTER = <internal table of type LVC_T_FILT>
Thanks, -
No column text displayed in alv when i use dynamic internal table
Hi friends,
when I use dynamic internal table to display the fields in ALV formant, field column text was not displaying ,
total row of column text was blank.
can u sujjest me in this...
with regards,
prasad.Hi
That depends on how you've filled the catalog table, here u need to insert the description for the labels (short, medium and long) and the description for the layout variant management.
So u make sure to fill the fields like
SCRTEXT_L
SCRTEXT_M
SCRTEXT_S
REPTEXT
Max -
Senarious for using different internal table types
please give scenarios for using different internal table types?
Refer to the following.
Internal table types
This section describes how to define internal tables locally in a program. You can also define internal tables globally as data types in the ABAP Dictionary.
Like all local data types in programs , you define internal tables using the TYPES statement. If you do not refer to an existing table type using the TYPE or LIKE addition, you can use the TYPES statement to construct a new local internal table in your program.
TYPES <t> TYPE|LIKE <tabkind> OF <linetype> [WITH <key>]
[INITIAL SIZE <n>].
After TYPE or LIKE, there is no reference to an existing data type. Instead, the type constructor occurs:
<tabkind> OF <linetype> [WITH <key>]
The type constructor defines the table type <tabkind>, the line type <linetype>, and the key <key> of the internal table <t>.
You can, if you wish, allocate an initial amount of memory to the internal table using the INITIAL SIZE addition.
Table type
You can specify the table type <tabkind> as follows:
Generic table types
INDEX TABLE
For creating a generic table type with index access.
ANY TABLE
For creating a fully-generic table type.
Data types defined using generic types can currently only be used for field symbols and for interface parameters in procedures . The generic type INDEX TABLE includes standard tables and sorted tables. These are the two table types for which index access is allowed. You cannot pass hashed tables to field symbols or interface parameters defined in this way. The generic type ANY TABLE can represent any table. You can pass tables of all three types to field symbols and interface parameters defined in this way. However, these field symbols and parameters will then only allow operations that are possible for all tables, that is, index operations are not allowed.
Fully-Specified Table Types
STANDARD TABLE or TABLE
For creating standard tables.
SORTED TABLE
For creating sorted tables.
HASHED TABLE
For creating hashed tables.
Fully-specified table types determine how the system will access the entries in the table in key operations. It uses a linear search for standard tables, a binary search for sorted tables, and a search using a hash algorithm for hashed tables.
Line type
For the line type <linetype>, you can specify:
Any data type if you are using the TYPE addition. This can be a predefined ABAP type, a local type in the program, or a data type from the ABAP Dictionary. If you specify any of the generic elementary types C, N, P, or X, any attributes that you fail to specify (field length, number of decimal places) are automatically filled with the default values. You cannot specify any other generic types.
Any data object recognized within the program at that point if you are using the LIKE addition. The line type adopts the fully-specified data type of the data object to which you refer. Except for within classes, you can still use the LIKE addition to refer to database tables and structures in the ABAP Dictionary (for compatibility reasons).
All of the lines in the internal table have the fully-specified technical attributes of the specified data type.
Key
You can specify the key <key> of an internal table as follows:
[UNIQUE|NON-UNIQUE] KEY <col1> ... <col n>
In tables with a structured line type, all of the components <coli> belong to the key as long as they are not internal tables or references, and do not contain internal tables or references. Key fields can be nested structures. The substructures are expanded component by component when you access the table using the key. The system follows the sequence of the key fields.
[UNIQUE|NON-UNIQUE] KEY TABLE LINE
If a table has an elementary line type (C, D, F, I, N, P, T, X), you can define the entire line as the key. If you try this for a table whose line type is itself a table, a syntax error occurs. If a table has a structured line type, it is possible to specify the entire line as the key. However, you should remember that this is often not suitable.
[UNIQUE|NON-UNIQUE] DEFAULT KEY
This declares the fields of the default key as the key fields. If the table has a structured line type, the default key contains all non-numeric columns of the internal table that are not and do not contain references or internal tables. If the table has an elementary line type, the default key is the entire line. The default key of an internal table whose line type is an internal table, the default key is empty.
Specifying a key is optional. If you do not specify a key, the system defines a table type with an arbitrary key. You can only use this to define the types of field symbols and the interface parameters of procedures . For exceptions, refer to Special Features of Standard Tables.
The optional additions UNIQUE or NON-UNIQUE determine whether the key is to be unique or non-unique, that is, whether the table can accept duplicate entries. If you do not specify UNIQUE or NON-UNIQUE for the key, the table type is generic in this respect. As such, it can only be used for specifying types. When you specify the table type simultaneously, you must note the following restrictions:
You cannot use the UNIQUE addition for standard tables. The system always generates the NON-UNIQUE addition automatically.
You must always specify the UNIQUE option when you create a hashed table.
Initial Memory Requirement
You can specify the initial amount of main memory assigned to an internal table object when you define the data type using the following addition:
INITIAL SIZE <n>
This size does not belong to the data type of the internal table, and does not affect the type check. You can use the above addition to reserve memory space for <n> table lines when you declare the table object.
When this initial area is full, the system makes twice as much extra space available up to a limit of 8KB. Further memory areas of 12KB each are then allocated.
You can usually leave it to the system to work out the initial memory requirement. The first time you fill the table, little memory is used. The space occupied, depending on the line width, is 16 <= <n> <= 100.
It only makes sense to specify a concrete value of <n> if you can specify a precise number of table entries when you create the table and need to allocate exactly that amount of memory (exception: Appending table lines to ranked lists). This can be particularly important for deep-structured internal tables where the inner table only has a few entries (less than 5, for example).
To avoid excessive requests for memory, large values of <n> are treated as follows: The largest possible value of <n> is 8KB divided by the length of the line. If you specify a larger value of <n>, the system calculates a new value so that n times the line width is around 12KB.
Examples
TYPES: BEGIN OF LINE,
COLUMN1 TYPE I,
COLUMN2 TYPE I,
COLUMN3 TYPE I,
END OF LINE.
TYPES ITAB TYPE SORTED TABLE OF LINE WITH UNIQUE KEY COLUMN1.
The program defines a table type ITAB. It is a sorted table, with line type of the structure LINE and a unique key of the component COLUMN1.
TYPES VECTOR TYPE HASHED TABLE OF I WITH UNIQUE KEY TABLE LINE.
TYPES: BEGIN OF LINE,
COLUMN1 TYPE I,
COLUMN2 TYPE I,
COLUMN3 TYPE I,
END OF LINE.
TYPES ITAB TYPE SORTED TABLE OF LINE WITH UNIQUE KEY COLUMN1.
TYPES: BEGIN OF DEEPLINE,
FIELD TYPE C,
TABLE1 TYPE VECTOR,
TABLE2 TYPE ITAB,
END OF DEEPLINE.
TYPES DEEPTABLE TYPE STANDARD TABLE OF DEEPLINE
WITH DEFAULT KEY.
The program defines a table type VECTOR with type hashed table, the elementary line type I and a unique key of the entire table line. The second table type is the same as in the previous example. The structure DEEPLINE contains the internal table as a component. The table type DEEPTABLE has the line type DEEPLINE. Therefore, the elements of this internal table are themselves internal tables. The key is the default key - in this case the column FIELD. The key is non-unique, since the table is a standard table.
http://help.sap.com/saphelp_nw04/helpdata/en/fc/eb35de358411d1829f0000e829fbfe/content.htm -
Passing Nested internal table to GUI_DOWNLOAD
Hi All
I have got a nested internal table, I want this whole report in excel format, I tried using GUI_DOWNLOAD , it gives error. Does any body have any idea how can I solve this.
regards
AJHi,
I think nested and deep structure internal tables will not work with gui_download.
you need to convert before giving it to gui_download
aRs -
Dynamically changing internal table in 'gui_download'
Hi Experts,
i have to download 4 internal tables, each with different structures, to the presentation server using 'gui_download', based on which radio-button is selected in the selection screen. I am hoping to use a single 'form' and 4 'perform' calls. how can I dynamically change the tables in the 'gui_download' function modules.
plz help.....................Hi ,
Build the field catalog dynamically based on the internal table structure based on the radio button selected.Use the dynamic internal table generated from the filedcatalog and use in GUI_DOWNLOAD.
See the below code:
*& Report ZRAJESH02
REPORT zrajesh02.
Dynamic internal table
TYPE-POOLS: slis.
FIELD-SYMBOLS: <dyn_table> TYPE STANDARD TABLE,
<dyn_wa>.
DATA: alv_fldcat TYPE slis_t_fieldcat_alv,
it_fldcat TYPE lvc_t_fcat.
DATA: lv_monate TYPE f,
lv_months TYPE i,
lv_date TYPE sy-datum,
p_check1 type n value '1'.
lv_date = sy-datum + 360.
SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-001.
PARAMETERS: p_check TYPE c.
SELECTION-SCREEN END OF BLOCK b1.
START-OF-SELECTION.
CALL FUNCTION 'MONTHS_BETWEEN_TWO_DATES'
EXPORTING
i_datum_bis = lv_date
i_datum_von = sy-datum
i_kz_incl_bis = ' '
IMPORTING
e_monate = lv_monate.
lv_months = lv_monate.
PERFORM f_fcat USING 'AUFNR' 'CHAR' '12'.
PERFORM f_fcat USING 'POSNR' 'CHAR' '06'.
while p_check1 LE p_check.
PERFORM f_fcat USING p_check1 'CHAR' '1'.
p_check1 = p_check1 + 1.
endwhile.
PERFORM build_dyn_itab.
LOOP AT <dyn_table> INTO <dyn_wa>.
WRITE:/ <dyn_wa>.
ENDLOOP.
FORM f_fcat USING fieldname dattyp length.
DATA:wa_it_fldcat TYPE lvc_s_fcat.
CLEAR wa_it_fldcat.
wa_it_fldcat-fieldname = fieldname.
wa_it_fldcat-datatype = dattyp.
wa_it_fldcat-intlen = length.
APPEND wa_it_fldcat TO it_fldcat .
ENDFORM. "f_fcat
*& Form build_dyn_itab
text
FORM build_dyn_itab.
DATA: new_table TYPE REF TO data,
new_line TYPE REF TO data.
wa_it_fldcat TYPE lvc_s_fcat.
CLEAR wa_it_fldcat.
wa_it_fldcat-fieldname = 'AUFNR'.
wa_it_fldcat-datatype = 'CHAR'.
wa_it_fldcat-intlen = 12.
APPEND wa_it_fldcat TO it_fldcat .
CLEAR wa_it_fldcat.
wa_it_fldcat-fieldname = 'POSNR'.
wa_it_fldcat-datatype = 'CHAR'.
wa_it_fldcat-intlen = 6.
APPEND wa_it_fldcat TO it_fldcat .
Create dynamic internal table and assign to FS
CALL METHOD cl_alv_table_create=>create_dynamic_table
EXPORTING
it_fieldcatalog = it_fldcat
IMPORTING
ep_table = new_table.
ASSIGN new_table->* TO <dyn_table>.
Create dynamic work area and assign to FS
CREATE DATA new_line LIKE LINE OF <dyn_table>.
ASSIGN new_line->* TO <dyn_wa>.
ENDFORM. "build_dyn_itab
Thanks,
Rajesh. -
Using an internal table from a strt rountine in an update rule
I created a start routine and i now want to take the value from the internal table and set my result to it in my update rule. I try that and it says it isn't a header table but I defined it this way. here is the code
DATA: T_BILL_DATA LIKE STANDARD TABLE OF /BIC/AZBIL_O5300,
Ls_data like line of T_BILL_DATA.
$$ end of global - insert your declaration only before this line -
FORM compute_key_field
TABLES MONITOR STRUCTURE RSMONITOR "user defined monitoring
USING COMM_STRUCTURE LIKE /BIC/CS2LIS_12_VCSCL
RECORD_NO LIKE SY-TABIX
RECORD_ALL LIKE SY-TABIX
SOURCE_SYSTEM LIKE RSUPDSIMULH-LOGSYS
CHANGING RESULT LIKE /BIC/VZSD_C51T-SALESORG
RETURNCODE LIKE SY-SUBRC
ABORT LIKE SY-SUBRC. "set ABORT <> 0 to cancel update
$$ begin of routine - insert your code only below this line -
fill the internal table "MONITOR", to make monitor entries
result value of the routine
READ TABLE T_BILL_DATA WITH KEY
DOC_NUMBER = COMM_STRUCTURE-DOC_NUMBER
S_ORD_ITEM = COMM_STRUCTURE-S_ORD_ITEM
REFER_DOC = COMM_STRUCTURE-DELIV_NUMB
REFER_ITM = COMM_STRUCTURE-DELIV_ITEM
BINARY SEARCH.
RESULT = T_BILL_DATA-SALESORG.Hi LMM,
The definition is not correct, your table doesn't have header line.
try this,
DATA: T_BILL_DATA LIKE STANDARD TABLE OF /BIC/AZBIL_O5300 with header line.
Hope it helps.
Thanks,
Soumya -
How to use dynamic internal table when using gui_upload?
Hi Experts,
my scenario is like i have header data, item data and serial numbers.
so with respect to the quantity in unit of measure ,there will be number of serial numbers..
i have declared the dynamic internal table,but i am not getting the logic to change the structure accordingly with respect to the flat file entries..
is it possible to do or its not possible....any suggestion!!!!i have declared like this....
TYPES: BEGIN OF ty_final,
bldat TYPE string, "Document Date
budat TYPE string, "Psting Date
bktxt TYPE string, "Document Header Text
werks TYPE string, "Plant
lgort TYPE string, "Storage Location
matnr TYPE string, "Material Number
erfmg TYPE string, "Quantity in Unit Of Entry
anln1 TYPE string, "Asset Number
anln2 TYPE string, "Asset Subnumber
sernr TYPE string, "serial Number
END OF ty_final.
DATA : it_final TYPE TABLE OF ty_final,
wa_final TYPE ty_final.
FIELD-SYMBOLS : <fs_final> TYPE table.
ASSIGN it_final TO <fs_final>.
after this i called gui upload and passed internal table it_final..
but i have to change the internal table structure dynamically before the upload function.so that it will match with the flat file...
Regards
KarthickThere are at least two approaches you can use to change/generate new dynamic-structured table. Either with [RTTI + RTTS|https://wiki.sdn.sap.com/wiki/display/Snippets/CreatingFlatandComplexInternalTablesDynamicallyusingRTTI] or using [CL_ALV_TABLE_CREATE|http://www.sdn.sap.com/irj/scn/advancedsearch?query=cl_alv_table_create] . In this one just determine fieldcatalog of current table and change it accordingly, then regenarate table.
There are plenty of examples in SCN for this. You should not face difficulties applying this.
Regards
Marcin -
How can i use the internal table as a WHERE clause ?
Dear Support ,
I have one internal table that save the material information ...
data : begin of itab ,
matnr like mara-matnr ,
end of itab .
And now i want to fetch the material desription text base on this internal table .
As i know that the "FOR ALL ENTRIES" statement is not allowed us to use "IN" this keyword ....
So , Has another solution for this case ? I don't want to use "LOOP AT ...." this way ...
Many thanks .
CarlosWhy can't you do
SELECT MATNR MAKTX INTO TABLE ITAB2 FROM MAKT FOR ALL ENTRIES IN ITAB WHERE MATNR = ITAB-MATNR.
Maybe you are looking for
-
Creation of Inspection Lot in QM Module without inspection lot origin
I want a solution regarding creation of inspection lot without assigning inspection lot origin to material code. We have developed function which creates inspection lot for the material against which PDI is envisaged on the material of a particular P
-
My ISP changed their email system. I have the same email address, but they have changed the account name to the full email address instead of just the first part of the email address. Example [email protected] My old User Name used to be Johndoe,
-
I have a mac mini that I use at work. Among other things, I'm the bookkeeper for our little business so it's pretty essential that it continue to live and be happy. I've noticed this week that everything is running slower than is normal and the compu
-
How do i change my iphone to another iphone using the same sim but keep all my photos and everything?
-
please advice me please :(