Visa issues

Hello,
i have a vi that has 25 'draw oval's' in the bolck diagram , this is interfaced with a microcontroller via RS232. The microcontroller is sending data continiousl. when I run the VI There is a big delay in reception by thhe draw oval vi's . WHen I used the same vi but with simple booleans (Leds) instead iof draw oval it works fine. All I am trying to do is read three bytes of data , creat an image (any format) and then save them in a directory. Attached is the VI (downconverted to 2012v) that I am having problems in when run through VISA. ANy help will be appreciated.
Regards
Attachments:
imagegen - Copy.vi ‏52 KB

naserkhan wrote:
thanksf for your reply. by 2nd while loop do you mean Producer/consumer technique? If yes then Can u give me some key tips to work on it.
Greatlyappreciate your concern
Producer/Consumer
There are only two ways to tell somebody thanks: Kudos and Marked Solutions
Unofficial Forum Rules and Guidelines

Similar Messages

  • VISA issues when switching from Labview 5.0 to 8.5

    Hello all
    I am using a pressure transducer that I read using RS-232. In Labview 5.0 I used the Read Serial VI and it worked with no issues (I also tested it with the VISA from 5.0 with no problems either). Now I have upgraded to 8.5 and I seem unable to communicate with it anymore. The usual error I get when i try to read is a timeout error.
    I ran the Troubleshooting Serial Line Monitor VI and it seems to work (RI blinks when the output lines are off, DCD RI and CTS blink when DTR is on, and RI DSR and CTS blink when RTS is pushed) The Basic Read and Write VI does not work however. Whenever I get bytes at port it always returns 0. I am using a USB-RS232 converter but this problem remains when I tried using an RS232 port on another computer running 8.2.
    I recently added the VISA 4.3 drivers but this did not help.
    Thanks for any ideas.
    Thomas

    This morning I tried with both the DOS prompt and Indigo terminal emulator. I also checked the setting on my manometer and the manual says that the settings should be:
    Baud Rate: 9600
    Parity: None
    Auto Line Feed: Yes
    Margin: 0
    Decimal Point: "."
    Send EOF: Yes
    I then followed the instructions to set the port with MODE COM5:9600,N,8,1,P and it returned
    transfer rate: 9600
    parity: none
    databits: 8
    stop bits:1
    timeout: on
    XON/XOFF: OFF
    CTS-handshaking: ON
    DSR-handshaking: ON
    DSR-sensitivity: OFF
    DTR cycle: Handdhake
    RTS cycle: Handshake
    Then when I try to log the data with COPY COM5 log.txt it creates a txt file on my desktop with no information.
    I checked the parameters on the old Labview 5.1 (not 5.0 as I said earlier) computer and they were
    Error Replacement Character: 0
    Flow Control XOFF Character: 0
    Flow Control XON Characcter: 0
    Serial Baud Rate: 9600
    Serial Data Bits:8
    Serial End Mode for Reads: Term Char
    Serial End Mode for Writes: None
    Serial Flow Control: None
    Serial Parity: None
    Serial Stop Bits: 1.0
    Those were the only parameters available in the Serial Settings Node
    With 8.5 I got all the same except
    End Mode for Reads: None (when I changed it to TermChar, it didn't help)
    XON: 17
    XOFF: 19
    There were many many more modem line settings but I didn't include them because they weren't in Labview 5.1

  • Chase MasterCard issues with Apple Pay

    I read back when Apple Pay was first rolling out, that only VISA issued Chase cards are comparable, but that MasterCard access would be added in March. It's now the second half of March, and I'm still not able to add my Chase debit card to Apple Pay. MasterCard's website says their cards work with Apple Pay. Chase's website says their credit & debit cards work with Apple Pay, yet my Chicago Bears debit card will not be added. It's extremely frustrating, and I'm curious when this will be able to be used.

    Linas Stempuzis wrote:
    Would be nice if Apple would give us an update since none here nor any Chase Service Rep has an inside track on this.
    Apple will not as they do not participate in and do not monitor this forum. And as you have correctly pointed out, nobody on this forum works for Apple,

  • I just came to hong kong to buy it but...

    hi community. Im from Costa Rica but recently im living in china ... when i came to china i lost my ipad ... so i wait till the new one gets out ... i came today fom Jinjiang ... with everything ready... and they told me that i needed to place a pre order ...
    Im learning chinese very hard ... but the reason i wait that long was the desition to have the new ipad ... i have to get back to china and wait for 3 months for my visa issues ... to be able to come back ... is anything Customer Support can make to help me ?
    Thank you all in advance...

    You're not addressing Apple here. This is a user-to-user tech support. At the bottom right of every page is a "Contact Us" link with other Apple contact information. Perhaps something there will be of use. However, given the short supply, I wouldn't hold my breath if I were you.

  • Lacie FW 800 PCMCIA card low speed in Vista

    I have a Lacie FW 800 pcmcia card - whith on my old Toshiba Qosmio would give me read speeds of greater than 50Mb per seconds. Now with my lovely new Satellite and Vista it barely reads @ 7Mbs and writes at a pathetic 2Mbs. Any idea's before I get rid of Vista as a waste of time.
    Dermot

    Hi
    Well, its not easy to say if its a PCMCIA slot issue or Vista issue.
    But I have noticed that some users have had a slow PCMCIA performance with Vista on different notebooks series. So I tending to say its a Visa issue.
    But it would also very interesting to know the performance with XP and then to compare the both results.

  • How to fix this error "this iPad is not able to complete the activation process. Please press Home and start over. If the issue persists, please visit your nearest Apple Store or Authorized service provider for more information or replacement"?

    How to fix this error "this iPad is not able to complete the activation process. Please press Home and start over. If the issue persists, please visit your nearest Apple Store or Authorized service provider for more information or replacement"? When I plugged in my iPad this popped up!

    Hi csreddy, 
    If you are receiving a message to contact an Apple Retail Store or Authorized Service Provider for help updating from iOS 3, click on the link below to initiate that support:
    Update the iOS software on your iPhone, iPad, and iPod touch - Apple Support
    http://support.apple.com/en-us/HT204204
    Update your device using iTunes
    If you can’t update wirelessly, or if you want to update with iTunes, follow these steps:
    Install the latest version of iTunes on your computer.
    Plug in your device to your computer.
    In iTunes, select your device.
    In the Summary pane, click Check for Update. 
    Click Download and Update.
    If you don't have enough free space to update using iTunes, you'll need to delete content manually from your device.
    Find out what to do if you get other error messages while updating your device.
    Last Modified: Jan 12, 2015
    Apple - Find Locations
    https://locate.apple.com
    Contact Apple for support and service - Apple Support
    http://support.apple.com/en-us/HT201232
    Regards,
    - Judy

  • Issue with adop fs_clone after upgrade to R12.2.3 on VIS instance

    I have installed EBS R12.2.0 Vision instance on Oracle Linux Server release 6.5 x86-64 with Unbreakable Enterprise Kernel release 3 (3.8.13-16.2.2.el6uek.x86_64) and then updated to R12.2.3.  Everything went smooth with the initial install, the AD and TXK patches, and the adop patching cycle for 12.2.3 update.  I'm having an issue with the running fs_clone which is the first post-update step from doc 1586214.1.  The other adop phases ran OK see below.  Also below is the error I'm getting and want to know if anyone has experienced this or any ideas?  I've googled and searched MOS but can't find a direct hit.  I'm new to adop and struggling to troubleshoot this....any help would be appreciated. I've run the fs_clone phase a couple times but got the same result.
    adop -status -detail (this is the R12.2.3 update cycle).  All steps seems OK here.
    Current Patching Session ID: 4
    Node Name       Node Type       Phase       Status          Started                        Finished                       Elapsed
    hn-s-sb13       master         PREPARE     COMPLETED       27-DEC-13 09:27:31 -05:00      27-DEC-13 09:55:35 -05:00      0:28:04
                                              APPLY       COMPLETED       27-DEC-13 10:11:53 -05:00      27-DEC-13 09:35:53 -05:00      11:24:00
                                              FINALIZE    COMPLETED       28-DEC-13 09:28:46 -05:00      28-DEC-13 09:29:52 -05:00      0:01:06
                                              CUTOVER     COMPLETED       28-DEC-13 09:32:12 -05:00      28-DEC-13 10:05:35 -05:00      0:33:23
                                              CLEANUP     COMPLETED       28-DEC-13 10:25:22 -05:00      28-DEC-13 10:48:31 -05:00      0:23:09
    File System Synchronization Used in this Patching Cycle: None
    Generating full ADOP Status Report at location: /u01/oracle/VIS/fs_ne/EBSapps/log/status_20131229_120910/adzdshowstatus.out
    Please wait...
    Done...!
    adop exiting with status = 0 (Success)
    From txkADOPPreparePhaseSynchronize_Sat_Dec_28_12_40_05_2013.log:
    ==========================
    Inside setCloneStatus()...
    ==========================
    Generating SQL file: /u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/fs_clone_20131228_123623/VIS_hn-s-sb13/TXK_SYNC_create_Sat_Dec_28_12_40_05_2013/5_DEREGISTER-ORACLE-HOMES.sql
    SQL Command: UPDATE ad_adop_session_patches SET clone_status = 'DEREGISTER-ORACLE-HOMES' WHERE status = 'N' AND bug_number = 'CLONE' AND node_name = 'hn-s-sb13' AND adop_ses
    sion_id = 5;
    Execute SYSTEM command : sqlplus ********* @/u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/fs_clone_20131228_123623/VIS_hn-s-sb13/TXK_SYNC_create_Sat_Dec_28_12_40_05_2013/5_DEREGI
    STER-ORACLE-HOMES.sql
    EXIT STATUS: 1
    SQL execution went through successfully.
    LOG FILE: /u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/fs_clone_20131228_123623/VIS_hn-s-sb13/TXK_SYNC_create_Sat_Dec_28_12_40_05_2013/5_DEREGISTER-ORACLE-HOMES.out.
    *******FATAL ERROR*******
    PROGRAM : (/u01/oracle/VIS/fs2/EBSapps/appl/ad/12.0.0/patch/115/bin/txkADOPPreparePhaseSynchronize.pl)
    TIME    : Sat Dec 28 12:42:54 2013
    FUNCTION: main::runFSCloneApply [ Level 1 ]
    ERRORMSG: /u01/oracle/VIS/fs2/EBSapps/comn/clone/bin/adclone.pl did not go through successfully.
    From adop_20131228_123623.log:
        ADOP Session ID: 5
        Phase: fs_clone
        [START 2013/12/28 12:39:57] fs_clone phase
          [EVENT]     [START 2013/12/28 12:40:01] Performing CLONE Steps
            [EVENT]     [START 2013/12/28 12:40:02] CLONE Patch File System from Run File System
              [EVENT]     Calling: /u01/oracle/VIS/fs2/EBSapps/appl/ad/12.0.0/patch/115/bin/txkADOPPreparePhaseSynchronize.pl
              [STATEMENT] Output directory: /u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/fs_clone_20131228_123623/VIS_hn-s-sb13
              [UNEXPECTED]Error occurred while executing <perl /u01/oracle/VIS/fs2/EBSapps/appl/ad/12.0.0/patch/115/bin/txkADOPPreparePhaseSynchronize.pl -contextfile=/u01/oracl
    e/VIS/fs2/inst/apps/VIS_hn-s-sb13/appl/admin/VIS_hn-s-sb13.xml -patchcontextfile=/u01/oracle/VIS/fs1/inst/apps/VIS_hn-s-sb13/appl/admin/VIS_hn-s-sb13.xml -promptmsg=hide -co
    nsole=off -mode=create -sessionid=5 -timestamp=20131228_123623 -outdir=/u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/fs_clone_20131228_123623/VIS_hn-s-sb13>
              [UNEXPECTED]Error occurred while CLONE Patch File System from Run File System using command: <perl /u01/oracle/VIS/fs2/EBSapps/appl/ad/12.0.0/patch/115/bin/txkADOP
    PreparePhaseSynchronize.pl -contextfile=/u01/oracle/VIS/fs2/inst/apps/VIS_hn-s-sb13/appl/admin/VIS_hn-s-sb13.xml -patchcontextfile=/u01/oracle/VIS/fs1/inst/apps/VIS_hn-s-sb1
    3/appl/admin/VIS_hn-s-sb13.xml -promptmsg=hide -console=off -mode=create -sessionid=5 -timestamp=20131228_123623 -outdir=/u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/fs_clone_20
    131228_123623/VIS_hn-s-sb13>.
              [PROCEDURE] [START 2013/12/28 12:42:55] Check and Stop Patch Admin Server
                [STATEMENT]         select count(1) from ad_adop_session_patches
            where applied_file_system_base='/u01/oracle/VIS/fs2' and
            patch_file_system_base='/u01/oracle/VIS/fs1' and
            bug_number IN ('CLONE','CONFIG_CLONE') and
            status IN ('N','F')
                [STATEMENT] There is a pending clone session for /u01/oracle/VIS/fs1.
                [STATEMENT] Skipping Check and Stop Patch Admin Server Step.
              [PROCEDURE] [END   2013/12/28 12:43:01] Check and Stop Patch Admin Server
              [UNEXPECTED]fs_clone phase completed with errors/warnings. Please check logfiles
              [PROCEDURE] [START 2013/12/28 12:43:03] Unlocking sessions table
                [STATEMENT] SQL stmt: <       begin
              AD_ZD_ADOP.UNLOCK_SESSIONS_TABLE('hn-s-sb13',60,2);
           end;
    >
              [PROCEDURE] [END   2013/12/28 12:43:07] Unlocking sessions table
              Log file: /u01/oracle/VIS/fs_ne/EBSapps/log/adop/5/adop_20131228_123623.log

    Randy,
    Looks like you need to add more space to /tmp directory as I see the following entries in CLONE*.error file.
    CLONE2013-12-28_12-41-01PM.error:
    =================================
    SEVERE : Dec 28, 2013 12:42:46 PM - ERROR - CLONE-20275   Insufficient space to create /tmp/CLONINGCLIENT8522798570339051663.
    SEVERE : Dec 28, 2013 12:42:46 PM - CAUSE - CLONE-20275   Minimum required space was at least "1,798" MB, but only "1,737" MB was available for use.
    SEVERE : Dec 28, 2013 12:42:46 PM - ACTION - CLONE-20275   Make sure that the minimum required space is available for use.
    SEVERE : Dec 28, 2013 12:42:46 PM - ERROR - CLONE-20233   Restoring Middleware home for sourceid "mwhome1@FMW_Home" has failed.
    SEVERE : Dec 28, 2013 12:42:46 PM - CAUSE - CLONE-20233   An internal operation failed.
    Thanks,
    Hussein

  • Need HELP (Project Issue) : Having 3 individual VIs, datalogger.vi, start vi, amksms.vi done. (How to run the VIs in sequence order - datalogger start amksms combine into 1 VIs? )

    Need HELP (Project Issue) : Having 3 individual VIs, datalogger.vi, start vi, amksms.vi done.
    (How to run the VIs in sequence order - datalogger > start > amksms combine into 1 VIs? )

    VIs in icon.
    how would it able to run in the sequence order:
    data first, follow by start and lastly amk sms.
    Attachments:
    dsa.jpg ‏10 KB

  • An issue (bug?) with Config File VIs?!

    Hello to all!
    When using Config File VIs I encountered a very interesting
    and killing (me) issue.
    I spent an hour before I knew where's a bug.
    (Maybe because I'm a novice to LabView).
    From one side, the bug was mine: I used a "for loop" to write string values to keys in section and provided to the loop an array that could be empty sometimes. And I absolutely forgot that "for loop" executes at least one time anyway even if array is empty.
    Ok, no problem, then the function "Write Key" should say "ERROR" and I would find my bug at once on the output of my "for loop".
    BUT IT DOESN'T DO IT. It says "OK".
    And only the next function "write key (string value in my case)"
    fails saying "Error: Config Data Registry.vi [get data]: invalid object 0". I certainly think that something wrong with this "write key", but what means this message?!
    Ok, I found who responds for this (the previous "write key" in for loop).
    But the most interesting thing is that if you set after this bad "for loop" one more such "for loop" you don't get error on the output of the 2nd "for loop" too. It appears only after "write key" that goes after 2nd "for loop".
    Well, forget it. Just look at attached files.
    Something wrong in this "Write Key" function if error goes far beyond its real source of arrising.
    Are you agreed? Or maybe I'm wrong?
    Thanks to all for attention.
    Any comments appreciated.
    Rashid.
    Using LV 8.0.1 Pro on WinXP.
    Attachments:
    Writing bad value to key.vi ‏22 KB
    Writing bad value to key 2.vi ‏24 KB

    Hi Ben, this was a good hint, last time I had problems with that zero iteration issue, I worked with LV 6.1 and kept in mind, that the shift register output was the last value stored in the Shift register output node, it reminded to the use of an uninitialized SR. If somebody still has 6.1 on the machine, it would be nice to test this. But the test with 7.1 showed you are right, the SR- input is reached through. Great!
    Thanks, dave
    Message Edited by daveTW on 06-16-2006 07:05 PM
    Greets, Dave
    Attachments:
    Shift register.png ‏5 KB

  • VISA Read timing issues

    I am using an RS232 to control an older model Power Supply (OXFORD PS 120-10).
    I have successfully written several VI's that all work, the only problem is that VISA Read takes WAY too long. I'm talking 10's of seconds to refresh. I need it have it refreshing in milliseconds or at least tens of seconds for the measurements we need. All of the VI's I have written have the same timing issue. 
    Attached is the most basic Serial Read/Write VI. Is there any way to improve the Read rate? Or might this just be an instrumentation issue. The strange thing is the Write commands work almost instantaneously (I can seem them on the instruments display).
    Please help if you can, I've only been working with LabVIEW for a few weeks and am very must still in the learning process. 
    Thanks!
    Solved!
    Go to Solution.
    Attachments:
    READandWRITE timing test.vi ‏14 KB
    READandWRITE timing test.vi ‏14 KB

    Do you have the communications protocol for the power supply? If you do not have everything right, you will have problems with communications.
    Tens of seconds is a clue that you may be getting timeout errors because the default timeout is 10 seconds. Try placing an inidicator on the error out wire inside the loop (after Read) to see if an error occurs on any iteration. The way you have the VI set up you only see the error on the last iteration of the loop.
    You are writing a carriage return to the instrument. If it requires that, it almost certainly sends a carriage return with the response. (This is why I asked about the protocol). If the instrument sends a carriage return (or other termination character), then you should Enable Termination Character on the Configuration VI and set the termination character to the correct value. The default is line feed (hex A or decimal 10). A carriage return is hex D or decimal 13. You must wire the numeric value to the termination character input for any value other than the default. Then change the byte count value (at the Read input) to a number larger than the longest message the instrument will ever send, perhaps 100 or 500. The Read will end as soon as the termination character is received, regardless of the number of characters.
    I suspect that this is the problem - the instrument sends fewer than 10 characters in most messages but does send a termination character.
    Lynn

  • VISA Debt Card Issued in Mexico and pick the items up at store.

    I live in Mexico and plan to travel to Chula Vista CA., I want to buy some items on November 27th, but they aren't available to pick up at Store by now. I plan to travel to USA between December the 5th and 7th. Is there any possibility to buy the items and to pick them up at store 188 Chula Vista on that dates? Another question. Do you accept payments with my international Visa Debt Card? I don't have a Credit Card. Or maybe I can pay when I pick up the items at store with that Debt Card. Could you please send me your comments? I will appreciate them and also your help. Thank you very much.

    Actually that is the store I work at and we certainly get quite a bit of international traffic. I can safely say we do accept valid Visa Credit cards even if they are issued in another country. Though as a warning I would reccomend calling the issuing bank before your trip to allow the card to be used. 
    Sometimes bank cards from Mexico are flagged as susspicious seing as cards are typically not used in other countries, calling the bank first should be able to clear it for such use. The currency is automatically converted.
    If you are going pick up an item in store you must have a valid ID and passports are accepted, also when placing the order you must use a special address as the billing address as the forms online do not allow Mexican addresses to be used. The address to use is as follows.
    10780 Kempwood Dr.
    Houston, TX 77043
    Feel free to come in for anything we can do for you. 
    I work for Best Buy as a mobile sales associate but all my comments, posts and opinions are my own and do not in anyway reflect Best Buy.

  • HT201303 My Visa Card was declined due to wrong security code entered by mistake. How I can solve this issue?

    My Visa Card was declined due to wrong security code entered by mistake. How I can solve this issue?  

    Welcome to the Apple Community.
    The following article(s) may help you.
    Credit card security code or postcode issues.     (10)

  • Labview visa write issue

    environment:
    -windows xp professional sp2
    -Labview 8.5
    description:
    I have an instrument with rs232 interface,  when I use UartAssist tool to send the command, the instrument could receive successful.
    but, when I start my labview application to use visa control, and send the exactly same command, there's no response.
    I trace the error during my control, there's no error occured after send command(send successful), but the instrument didn't response.
    I'm sure the baudrate and other configuration is right, why the instrument can not response?
    BTW, I try using the HyperTerminal to send the same command, the instrument can response too...
    Solved!
    Go to Solution.

    Ryan Ge wrote:
    Termination issue! Thanks for your suggestion.
    Labview needs a carriage return constant to append the command string, I thought that type a carriage return in command string is ok.
    So that's why the instrument didn't response.
    You can, but the problem is that when you press "Enter" on the keyboard to enter a new line in a string constant or control what gets entered is a newline character, not a carriage return character. You can see this by setting the display mode of the string constant/control to '\' display mode, as seen here:
    You can replace the "n" at the end there with "r" to get a carriage return instead of a newline. Note that you need to be in '\' display mode for this to work correctly. 
    Message Edited by smercurio_fc on 10-17-2008 09:32 AM
    Attachments:
    Example_VI_BD.png ‏1 KB

  • Labwindows CVI 2009 compatible issue with VISA 4.4.1?

    Hi,
    I would like to understand is there any compatible issue for Labwindows CVI 2009 with NI VISA 4.4.1? If so can you please direct me to the right document where this is document.
    Can you also tell me what is the version of NI VISA for Labwindow CVI 2009. Please reply at the earliest.
    Regards,
    Usha

    Apparently HP has stopped updating that application for Firefox. It wasn't available for Firefox 3.6 last year and now - not for 4.0 either.

  • I have one problem and I think it is a settings issue. When I google the web I get results. Now, when I visit some website and I return to my search results I don't have any markers (diffrent link colour for visited sites in IE).

    Question
    I have one problem and I think it is a settings issue. When I google the web I get results. Now, I visited some website and then I want to return to my search results and pick another search result. And there is a problem: I don't have any markers (diffrent link colour for visited sites in IE) that would help me to distinguish visited and not visited sites.

    Why start a new and very similar thread to your other one which you have not responded to (have you read the replies?)
    I suggest that no response is made to this duplicate thread. 

Maybe you are looking for

  • Changing audio

    I have the audio from the original video but I want to silence3 this and put my own mp3 on - just downloaded the trial version - adn having trouble finding out how to do this. I was able to add something called smart audio (or something like that) -

  • Connectivity issues with AE card after v4.2 update on 10.3.9

    Teach me not to read up on updates before installing them, though I suppose I shouldn't have to....grr. Stupid lack of quality control. Anyway, I have a 1.25ghz PB running os 10.3.9, and my network was running just fine before I installed the update.

  • Text on Preview keeps turning sideways!!!

    So I use Preview for taking notes in class. I just add text boxes on top of the slides and save it afterwards. It usually works great. But the last few PDFs, even though I type all the text correctly and save it before I close, I will reopen the PDF

  • How to improve nokia messaging

    Dear Nokia developers, the new Nokia email messaging service has become quite stable over time. Good work here. I have some ideas how to improve the client, perhaps you can put this on your roadmap: 1. Combined view of all mailboxes, so I don't have

  • Check_requirements - When updating ST-PI thru SPAM

    Hi Experts, I am applying SAPKITLQG8 package and I am getting the following message : Phase CHECK_REQUIREMENTS: Explanation of the Errors Open Data Extraction Requests The system has found a number of open data extraction requests. These should be pr