XI Adapter and PCK

How XI identify Sender system through XI Adapter?
Foe example I have 2 PCK. I create 2 system PCK1,  PCK2 and 2 sender channels with XI Adapter. Each sender PCK uses different interfaces. Each PCK is configured with receiver channel with XI Adapter (http://server:8000/sap/xi/engine?type=entry)

Hi Sergey,
Hava a look at these links:
http://help.sap.com/saphelp_nw04/helpdata/en/e1/091640a991c742e10000000a1550b0/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/4f/0a1640a991c742e10000000a1550b0/content.htm
http://help.sap.com/saphelp_nw04/helpdata/en/f4/0a1640a991c742e10000000a1550b0/content.htm
Cheers,
Chandra

Similar Messages

  • SOAP Adapter and PCK ??

    Hi,
    I want to implement following scenario.
    .Net Application -> XI -> R/3
    I think the best way would be using a SOAP adapter
    SOAP->XI->RFC(to R/3).
    Can anyone pls let me know , what are the steps that need to be performed to make this happen ?
    Also do I need Partner Connectivity kit to implent this particular scenario , or when would I want to use PCK ?
    Thanks ,
    Vivek
    PS : Point will be definitely awarded

    Hi Vivek,
    Configure your Soap Sender Adapter as given in the link below :
    http://help.sap.com/saphelp_nw04/helpdata/en/fc/5ad93f130f9215e10000000a155106/content.htm
    For configuring your receiver RFC this weblog might be useful
    /people/arpit.seth/blog/2005/06/27/rfc-scenario-using-bpm--starter-kit
    Steps :
    1) <b>Design Part</b>
    1. Create the data type, message type for input( from your .net Application) in XI
    2. Create a Synchronus Message Interface for the input side (SOAP Adapter).
    3. Import the required RFC.
    4. Do the corresponding Message Mapping and Interface Mapping.
    2) <b>Configuration Part</b>.
    1. Add the Business System and the Service (SOAP) needed.
    2. Create the communication channels
      a) SOAP (sender)
      b) RFC (receiver)
    3. Create the sender agreement, receiver determination and receiver agreement.
    4. Now create the wsdl file (using the tools -> Define Web Service of Integration Directory).
    5.Save the wsdl file.
    6. Now create your .Net application and add your wsdl file to that (as Web Reference).
    Hope it will be helpful.
    For any other doubts do revert back.
    Regards
    Suraj

  • Is it possible to test XI Adapter on PCK by JNDI lookup?

    Hi, friends
    I can't test the XI Adapter by using the communication channels and sender/receiver agreements on a standalone PCK (without XI server to be connected). Is it possible to test XI Adapter on PCK by JNDI lookup?
    I can locate the XI Adapter by JNDI lookup (JNDI name is configured on SampleRA.xml):
    ConnectionFactory cxf = (ConnectionFactory)initctx.lookup("deployedAdapters/sample_ra/shareable/sample_ra");
    But later it failed to get the ConnectionSpec and create the Connection. Could anyone give me a sample code for testing XI Adapter by JNDI lookup?
    Thanks in advance.
    Best Regards,
    Jason
    Message was edited by: Jason Wang

    Hi,
    I'm not sure if this is what you are looking for but
    check the link "Using Resource Adapter to Obtain Connection" on this site:
    http://help.sap.com/saphelp_nw04/helpdata/de/89/b262427a65423f87706a0e3faea00d/frameset.htm
    Hope it helps,
    Christian

  • SOAP Adapter in PCK

    Hi,
    I am trying to get the SOAP Adapter in the PCK running, but always get an error while sending a SOAP message to the adapter. I configured the send adapter as described under help.sap.com and when I try to check the availability of the channel by accessing the url
    http://localhost:50000/XISOAPAdapter/MessageServlet?channel=PartyA:SOAPService:soapchannel.
    I always get the following Error:
    Message Servlet is in Status ERROR
    Status information:
    Servlet com.sap.aii.af.mp.soap.web.MessageServlet (Version $Id: //tc/aii/30_VAL_REL/src/_adapters/_soap/java/com/sap/aii/af/mp/soap/web/MessageServlet.java#5 $) bound to /MessageServlet
    Classname ModuleProcessor: null
    Lookupname for localModuleProcessorLookupName: localejbs/ModuleProcessorBean
    Lookupname for remoteModuleProcessorLookupName: null
    ModuleProcessorClass not instantiated
    ModuleProcessorLocal not instantiated
    ModuleProcessorRemote not instantiated
    The file adapter is working without any problems.
    Can anyone tell me what I am doing wrong?
    Regards,
    Ulf

    Hello Hans Christian,
    thank you for your reply. The Helper Servlet returns the following:
    <?xml version="1.0" ?>
    - <s:ChannelInfo xmlns:s="http://sap.com/xi/WebService/xi30">
      <channelID>748d6d504759d17c711b6540538844c3</channelID>
      <name>soapchannel</name>
      <type xmlns:st="http://sap.com/xi/XI/System">st:SOAP</type>
      <direction>INBOUND</direction>
      <party>PartyA</party>
      <service>SOAPService</service>
      </s:ChannelInfo>
    I think my problem might have something to do with jndi, because it seems, that the ModuleProcessorBean can not be found (The message servlet returns "ModuleProcessorLocal not instantiated" and when I look in the server log files there is also a NameNotFoundException during the lookup of ModuleProcessorBean.) Could this have something to do with my problem?
    I am now trying to update the WebAS and PCK to the latest support package and hope, that this helps somehow.
    Thanks in advance for any further help.
    Regards,
    Ulf

  • Difference In RFC Adapter and XI proxy

    I am using RFC adapter for master data and XI proxy for transaction data , can anyone tell me what is major difference and what is negative point in using RFC adapter
    Thanking you
    sridhar

    Hi,
    Adapters enable the Integration Engine and the Partner Connectivity Kit (PCK) to communicate with different applications.Adapters connect the Integration Engine to SAP legacy systems, as well as to external systems.
    In this way, adapters integrate existing SAP components with SAP Exchange Infrastructure, for example. In the process, XML and HTTP-based documents are converted to IDocs (IDoc adapter) and RFCs (RFC adapter) and the other way around. This enables you to integrate your existing SAP infrastructure with the new SAP infrastructure, which is based on system integration and the exchange of XML messages.
    The plain HTTP adapter gives application systems the option of communicating with the Integration Engine and exchanging business data in a simple format, using an HTTP connection.
    RFC Adapter :
    The RFC adapter enables you to use the functions of the Integration Engine or the PCK in existing SAP landscapes. It is used by SAP systems to connect to the Integration Engine or the PCK by using the RFC interface. It supports SAP systems as of version 3.1x.
    For FAQs about the RFC adapter, see SAP Note 730870
    The RFC adapter is provided by the Adapter Engine and the PCK. It essentially comprises two parts, namely a sender adapter at the Integration Engine inbound channel, and a receiver adapter at the Integration Engine outbound channel.
    The adapters are configured in the configuration part of the Integration Builder, or in the configuration part of the PCK. You use the SAP Java Connector (JCo), which enables you to manage metadata. This in turn enables you to map RFC data generically to RFC XML and the other way around.
    The receiver RFC adapter can be used for mapping lookups.A communication channel with a receiver RFC adapter can be created automatically for business systems that are defined in the System Landscape Directory.
    The RFC adapter maps the following RFC calls to XML messages and the other way around:
    Synchronous RFC calls (sRFCs) in messages with quality of service Best Effort (BE)
    &#9679;     Transactional RFC calls (tRFCs) in messages with quality of service Exactly Once (EO)
    &#9679;     The receiver RFC adapter can also process messages with quality of service Exactly Once In Order (EOIO). They are mapped to transactional RFC calls (tRFC).
    You require the sender adapter if you want to use the Integration Engine or the PCK to process RFCs. The RFC adapter converts the incoming RFC data to XML message format (RFC XML) so that it can be processed by the Integration Engine or the PCK.
    You require the receiver adapter if the determined receiver system expects the data from the Integration Engine or the PCK to arrive in RFC format. In this case, the Integration Engine or the PCK must transfer the received XML message (RFC XML) to the RFC adapter. The RFC adapter converts the RFC XML message to a valid RFC call and executes the call.
    Proxy :
    Generally speaking, interfaces are where functions in a system can be executed. In the context of SAP Exchange Infrastructure, only the following interfaces are relevant:
    ·        Interfaces designed for message exchange between application systems
    ·        Interfaces used by a cross-component integration process to receive or send messages, or both
    Starting with a cross-system integration process, you can then derive the corresponding interfaces required. SAP Exchange Infrastructure supports this process by using an integration scenario to describe the collaborative process. The integration scenario summarizes the interfaces required for this collaborative process.
    You can use SAP interfaces that already exist in systems, non-SAP interfaces that are connected to SAP Exchange Infrastructure using adapters, or define new interfaces called message interfaces in the Integration Repository. Both worlds can also be interconnected in a collaborative process.
    Interfaces are an essential component of SAP Exchange Infrastructure:
    ·        You define the interfaces to be used in an integration scenario.
    ·        Cross-component integration processes use interfaces to exchange messages.
    ·        You define the XML transformations for messages that are to be exchanged between two interfaces in a mapping.
    ·        You assign an interface in a sender system to one or more interfaces in a receiver system in logical routing.
    ·        You generate proxies to implement your scenario based on message interfaces.
    You save interface descriptions (message interfaces, BAPIs, RFCs, and IDocs) in the Integration Repository so that they can be referenced throughout SAP Exchange Infrastructure. However, adapters for external systems do not normally use interfaces; instead they access files or database tables in order to function, for example. For this reason, it is not necessary to import these interfaces into the Integration Repository. If the structure of the message is described using a WSDL, XSD, or DTD schema, you can import the schema as an external definition.
    Hope this will help you.
    Regards
    Aashish Sinha
    PS : reward points if helpful

  • Scenarios using Sender JMS adapter and Reciver JMS adapter

    Hi All,
    I am not able to find god step by step blog on senderJMS adapter and Receiver JMS adapter.
    also please explain when we use JMS.What does a messng system means?please provide some examples.
    Thanks and regards

    Hi  Goyal,
    Messaging System :
    Messaging system allows separate, uncoupled applications to reliably communicate asynchronously. The messaging system architecture generally replaces the client/server model with a peer-to-peer relationship between individual components, where each peer can send and receive messages to and from other peers.
    Go thru this you will get better idea :
    http://java.sun.com/developer/technicalArticles/Networking/messaging/
    JMS adapter (Java Message Service) enables you to connect messaging systems to the Integration Engine or the PCK.
    regards
    Ganga

  • Testing Adapter in PCK

    I am trying to test sample adapter in PCK Server (Scenario PCK -Sender to PCK-Receiver, cc - sample Adapter). I configured scenario per help.sap.com. in CC Monitoring, it shows as it is functioning and in green legend. Even though I configured sender agreement and receiver agreement, it is not picking file and not doing anything.
    I configured NWA with relevenat config (authorization of user, isconfig url, internal, user, password etc ) as per help.sap.,com.
    Did any one come across this issue?  I appreciate your help.
    NOTE: you will get double points for right answer, with my subscription
    Thanks,
    Ravi Appala
    919 386 0221

    May be some basic check can help:
    1) file location and filename(alongwith extension) are maintained properly in the channel
    2) if possible use the IP address of the file server from where the file is to be picked up.
    3) In case of XI/ PI when such a thing happens, it is blamed on the adapter being locked. If the adapter is locked it will just show message in CC monitoring like processing started (something similar), however in reality the channel is not able to pick the file because the adapter is locked...check if it is the issue for you...not sure if the procedure to check for adapter is the same for PCK and XI/ PI....it is done through Visual Admin in 7.0 and in NWA for 7.1
    Regards,
    Abhishek.

  • Apple Mini-DVI to Video Adapter and Mac mini (2009)

    Can anyone tell me whether the Apple Mini-DVI to Video Adapter listed here:
    http://store.apple.com/ca/product/M9319G/A
    works with the latest Mac mini (early 2009)?
    If it does not what other solutions are there to connect to composite, component or s-video?

    KC from Ann Arbor, MI had this to say as a review on the page to which you have linked;
    10-May-2009
    I bought a Mac Mini (May 2009) and this Mini-DVI to Video adapter with plans to use it to send an S-video signal to an analog TV. Though the sales staff at the Apple store said it should work, it does not. The graphics card apparently should support it, and it may be addressed with a future driver update, but as of now this does not work. I have used a mini-DVI to VGA adapter and monitor to verify that the port is working, and also verified that the S-video cable and TV input work. There are third party VGA to S-video/RCA adapters available so I plan to use one of those for my purposes. This is probably a 5-star product when used with the right Mac; however, Apple should have made it clear that having a mini-DVI port on your Mac is necessary but not sufficient for this to work - hence the 3 stars.

  • I have a targus 4.0 bluetooth usb adapter and so i can pair my iphone 4s and ipad air wirelessly, it seems to pair ok but when i try to connect i get a error message or not compatible. can some one tell me if it i can use this

    i have a targus 4.0 bluetooth usb adapter and so i can pair my iphone 4s and ipad air wirelessly, it seems to pair ok but when i try to connect i get a error message or not compatible. can some one tell me if it i can use this bluetooth with my devices, thanks

    sos1der wrote:
    pairing the apple equipment is not a big deal just wanted to add songs from itunes wirelessly.
    You can only add songs to your iOS device from iTunes via Wi-Fi sync or via your cable, not Bluetooth.
    sos1der wrote:
    but i tried paring my LG bluetooth so i can listen to music on my computer wirelessly buy it gives me the same error message
    That's an entirely different issue, unrelated to your iOS devices.

  • I have a late 2008 white macbook.  I have a mini dvi to hdmi adapter, and a hdmi cord.  My cannot get my MB to detect an external monitor.  Nothing happens when plugged in.  Also, my display settings does not have an option for mirroring or arrangment tab

    I have a late 2008 white macbook.  I have a mini dvi to hdmi adapter, and a hdmi cord.  My cannot get my MB to detect an external monitor.  Nothing happens when plugged in.  Also, my display settings does not have an option for mirroring or arrangment tab

    Yeah, I'm having the same exact problem - It seems that the thunderbolt minidisplay port is only able to output the analog VGA signal, not the digital signal to support DVI and HDMI. This is a bug that came up after installing 10.7.1. I bought my macbook air with 10.7 on it, upgraded it to 10.7.1 as soon as I got it, so I have never been able to use hdmi or dvi with my macbook air. This is an extremely frustrating problem for me, I used HDMI on a daily basis with my PC. I have spent many hours at the genius bar running diagnostic tests so Apple can get as much information as possible to create a fix for this problem. I have been emailing tech support for 3 or so weeks now, they keep saying that they are working on a fix and it should be out soon, but 10.7.2 has come and gone and I still have no HDMI functionality with my MacBook Air!

  • HT4108 I'm trying to connect my iPad to my tv so that I can mirror whatever is on my iPad. I want to stream movies online and watch on the tv. I have the digital av adapter and an hdmi cable but it's not working. Any tips ?

    I'm trying to connect my iPad to my tv so that I can mirror whatever is on my iPad. I want to stream movies online and watch on the tv. I have the digital av adapter and an hdmi cable but it's not working. Any tips ?

    If this is an iPad 1, it won't mirror, but it will still output video from the 30 Pin dock connector.
    If your new TV has a conventional VGA in and stereo inputs you can try this connector.
    http://store.apple.com/us/product/MC748ZM/A/apple-composite-av-cable?fnode=3a
    I used to stream video from both Netflix and YouTube and from my Mac using iTunes sharing through my iPad then with this connector plug into my iPad and TV.
    It won't be high resolution, but it will get you picture from iPad to TV.
    Good Luck.

  • I've just hooked my 20" iMac up to my Toshiba 37" HDTV using a mini dvi-HDMI adapter, and works well, EXCEPT for the green tinge (or hue) that is showing up on my TV. Any suggestions or ideas?

    I've just hooked my 20" iMac display up to my Toshiba 37" HDTV using a mini dvi-HDMI adapter, and everything works well, EXCEPT for the green tinge (or hue) that is showing up. Everything else looks pretty good though..... The color that is on my iMac is still good, Its just green on the TV.
    Anyone have suggestions or ideas?

    Try opening the Display System Preferences, then click on the Color options in the Display preferences window that appeared on the Toshiba display. Click on the Calibrate button and follow the instructions for creating a custom ColorSync profile that will hopefully solve the green tinge issue. The Apple Display Calibrator Assistant software that launches when you click on the calibrate button will walk you through the process.Assuming that the green tinge is minor and that you don't have a more serious cable or hardware issue, I am hopeful the results will be worth it.

  • Can I use a mini display port to VGA adapter and then a VGA to av adapter to connect my MacBook pro to my standard definition tv?

    Can I use a mini display port to VGA adapter and then a VGA to av adapter to connect my MacBook pro to my standard definition tv?

    No. You need a converter box like this to go with your MDP-VGA adapter:
    http://www.amazon.com/PC-To-TV-Video-Converter/dp/B001CJOLBW/ref=pd_cp_e_2

  • How can I split the video port of an older Mac Mini so I can use both the 922-6199 DVI to RCA, S-Video Adapter and a Cinema Display?

    How can I split the video port of an older Mac Mini so I can use both the 922-6199 DVI to RCA, S-Video Adapter and a Cinema Display?

    Which exact Mini?
    At the Apple Icon at top left>About this Mac.
    Then click on More Info>Hardware and report this upto but not including the Serial#...
    Hardware Overview:
    Model Name: iMac
    Model Identifier: iMac7,1
    Processor Name: Intel Core 2 Duo
    Processor Speed: 2.4 GHz
    Number Of Processors: 1
    Total Number Of Cores: 2
    L2 Cache: 4 MB
    Memory: 6 GB
    Bus Speed: 800 MHz
    Boot ROM Version: IM71.007A.B03
    SMC Version (system): 1.21f4

  • Connect two external monitors to mini DP(using a mini DP to VGA adapter) and the VGA out at once

    I am trying to  connect two external monitors to mini DP(using a mini DP to VGA adapter) and the VGA out at once. Windows recognize both monitors as well. But it dowsn't let me use all three monitors at once(see the below image). In the dropdown, it lists all three monitors. Problem is there are two active displays I can select.

    Mavec wrote:
    I would like to add a third monitor.  
    The GPU(s) in your T400 (and most other laptop brands) will support two different displays concurrently.  If you want to support more than two different displays concurrently, you will need another GPU external to the T400.
    Generally, if you want to use two external displays on a T400 you will nee dto use a docking station.
    I have read messages on various fora on this topic and know that there are a number of ways of doing this, but as I have never had a need to do this myself I can't tell you how to go about it.
    Cheers,
    Bill
    I don't work for Lenovo