Connecting two BI systems to one R/3 system

Hi Experts,
We are upgrading our BW 3.x to 7. This activity we are doing on a sandbox server. Now for integration testing we want to connect this BI sandbox to R3 QA system. RFC destination parameters are maintained in both the systems.
Now when we go for source system Restore option from DW workbench, it pops up with message -
"Connection AA is used in the ARQ100 (R/3 QA) source system as a connection ABQ100 (BI QA).
Do you want to delete this connection in the source system? Connection is restored after it has been deleted successfully."
I checked in RSBASIDOC table in R3 QA system, there exists this entry to ABQ100.
My question is - without touching the R/3 QA -> BI QA connection, can I create a connection between R/3 QA & BI sandbox? & How?
or Can we create new connection similar to AA for this new BI sandbox system?
I have already gone thru SAP Note - 775568, but it does not mention anything related to my scenario.
So appreciate help from experts.
Regards,
Vikram.

Hi WernerS,
Thanks for the reply.
Both the BI systems have diff Logical Sys names. And at this time I am not concerned about delta.
But as I mentioned earlier, while trying to restore source system from new BI sandbox server, it is asking to delete the connection from R/3 QA to BI QA which I dont want.
My question is How to establish this new connection without disturbing the existing R3 QA to BI QA connection.
Regards,
Vikram.

Similar Messages

  • Connecting two BW systems to the one R/3 source system

    Hi all!
    I have to connect two BW Systems to one R3 system. In our last tests we have had problems trying to connect two BW  servers simultaneously with R/3 source system because it allows only a logical system name for each R/3 client, and (We guess that we need to define tow diferent logical system name, one for each connection). This has been generating errors when we try to load data from R/3 to BW because, we guess, R/3 does not recognize the BW source system in the ALE connection for someone BW systems at transfer data. In this moment I have one connection active (BW1-R3). The BW2-R3 connection is already inactive. Does anybody know how perform this? we need solve the transfers problem as soon as possible.
    Thanks!  Judi

    Ah...
    please don't post twice the same question...in these forums we are always the same !!!
    You can close this thread to avoid to look in two different posts...
    Bye,
    Roberto

  • When we connect two bw systems to one R/3 system?

    Hi ,
    When we connect two bw systems to one R/3 system,
    could you please exlain what is the imact to SAP and BW in terms of query performance, batch performance,Develoment ,Quality system,security,BW Support.
    Thanks in advance.
    Regards,
    kranthi

    you can connect multiple BW to single R3 source system.
    In the delta queue (RSA7 in source system), you have a field with the target system, so you don´t have problem if you have many target bw system, because the data selection is done by system field.
    Challenge arises when you have multiple R3 feeding to single BW system and then you have to consolidate the master data say 0material fed from different source system R3 then you can consolidate data using consolidated infoobject.
    The following components concatenate to the key of a consolidated InfoObject:
    1)source system ID (two-character source system ID; permitted values are stored NW BI table RSSOURSYSTEM)
    2)one blank character
    3)backend object type (four-character backend object type; permitted values are stored BI table RSBWBEOTYP)
    4)master data key value as stored in the source system
    Note that the key of a consolidated InfoObject solely consists of non-integrated informations from the different source systems. Integration across source systems results from a (maybee repeatedly applied) data consolidation and cleasing process which unveils duplicate master data keys.
    Hope it Helps
    Chetan
    @CP..

  • Can a R3 system connect two XI  system?

    Hi,gurus:
    Can a R3 system connect two XI  system?In SM59 we have to point the rfc to a single xi.Is it right?

    If my scenario is about idoc,we can define two RFC in SM59,
    and two partners in WE21 and two ports in WE20,right?
    Correct..
    If my scenario is about abap proxy,then we can define two RFC in SM59,
    and two parameters in sxmb_adm in the R3 side,right?Then in the tcode:SPROXY,
    we can see both interfaces in two XI systems,right?
    this is not posssible...

  • Connect two ECC systems with one SAP CRM 7.0

    Hi Gurus!
    I have to do a customizing for connect two ECC 6.0 and one SAP CRM 7.0, only I need the organizational structure from both systems and they need update when the structure from CRM has changes. The business partner goes to ECCs system by PI interfaces.
    Both organization models are different, so I have to maintain and update depending the changes in the business.
    But I don't know if this is possible, I don't know if we can do this by Middleware, ALE or PI.
    Can you please, give your oppinion about this topic?
    Best regards,
    Eugenia.-

    Hi Eugenia,
    Please see note 1084315 which descriibes the the multiple backend scenario.
    This should be relevant here.
    Best regards
    Christophe

  • Connect two BW systems to one source system

    Hi Experts!
    I would like to know if I can set up two BW systems connect to one source system.  We copied and built new BW system (BW2) from existing BW system (BW1).  We need to have both system connect to one source system.  When I execut Restore from BW2 - RSA1 - Source System, I'm getting a following prompt:
    "Connection cannot be used. The connection BB is used in the DEV400 source system as a connection BW1400 to BW. Do you want to delete this connection in source system".
    If I select "Delete" then it replace exising connection between BW1 - DEV and creates new connection BW2 - DEV.  If I go back to BW1 and do restore then same thing happens as BW2 connection removed.
    Is there anyway we can set up two BW systems connection to one source system with restore?  Connection works fine since each one can connection with no issues.  Just when I do restore, it removes other connection.
    Thanks.

    Check if it helps:
    Loading two different SAP BW system from one SAP R/3

  • Connecting two SCL systems to one backend

    Hi,
    Is it possible to maintain 2 SCL system connections to one ECC system? We have already connected one SCL system to ECC as a backend and now we want to connect second one.  Is it possible to do that?
    If yes how to maintain Logical Ports call parameters for that?
    Thanks
    Domas

    Hi Domas,
    As pointed our by Holger, this is supported for inbound flows where your use case is to read (pull) some information from SAP into SharePoint. But use cases like reporting and workflow which publishes some items in SharePoint you cannot have the same ECC system.
    But if you intention is only for DEV landscape setup and want to save a VM image and still want to support reporting & WF scenarios, then you could also create a new client which is the copy of your existing clients in the same ECC system.
    Since logical port configurations are client specific you could practically connect same ECC system (but 2 diff clients) to 2 gateway systems.
    Thanks,
    Girimurugan

  • How to connect two BW systems to one ECC system?!?

    Hi Experts!
    We want to connect our ECC system (P11) to multiple SAP BW systems. Therefore we made a system copy of our productive BW System (P81) and create a new second BW System (T81). When I want to restore to connection to the P11 in the T81, Iu2019ll get the following error message:
    u201CDie Verbindung CA wird im Quellsystem P11_001 als Verbindung zum BW T81CLNT001 genutzt.
    Soll diese Verbindung im Quellsystem gelöscht werden? Nach erfolgreicher Löschung wird der Anschluss wiederholt.u201C
    In English this message means something like that: u201EThe connection CA is used as a connection to the BW T81CLNT001 in the source system. Should this connection be deleted in the source system? This connection can be repeated after successful deletion.u201D
    Now I ask myself: How can I connect our new BW System to our ECC System, without destroying the old connection to our productive BW system?!?
    Have anyone of you an idea how we can handle this issue?
    Thanks in advance!
    Regards, Alex

    Hi
    This happens because of RFC settings duplication as your new BW system is copied from Old one.
    First you restore the Production system connection by deleting the existing RFC.  But this will delete the new connection you have created ( that is what your dialog message is saying) 
    Basically , before creating new connection you need to delete some table entries manually , then you can connect both the system to your same source system
    Please find the link below where I mentioned the table names from where you need to delete duplicate entries manually.
    How to delete old source system assignment and assign new source system.
    Regards
    Anindya
    Edited by: Anindya Bose on Oct 13, 2011 9:01 PM

  • Connecting two BW systems to 4.6 C OLTP SYSTEM

    hello experts,
    i got issue while creating source system in BW SYSTEM.
    My is i trying to conect single oltp source system(4.6C) to TWO BW clients
    one system is having connection already... now i am trying to connect other system.
    all the RFC Conections looks fine from the both the systems..
    here the problem is i am getting error saying source system cannot to created.
    as error occured in the oltp system... when i cheked in R3. THERE IS SHORT DUMP.
    .....can pls help on ythis process... what steps do i need to follow
    other issue.
    same rfc connection between CRM AND BI client.
    when i try to create crm source in bi...all rfc connetions are fine
    i am getting error is source does not exist.
    this is minor issue
    i want help on the FIRST ONE.. THAT IS REALLY IMPORTANT
    THANKS
    NAG

    Hi Roberto,
    Thaks for your quick answer! that is usefull for configuring the system after the connection! but, I need that the connection work properly first. itsn't the case. We connect the both systems to R3 and defined the background user's for connection, but at moment to transfer data the process is not initiated in R3 (back job) for the BW2-R3 link. But for BW1-R3 does. then, we had changed the BW1-R3 link by changed the logical system name in R3, for connect BW2-R3 and this is working correctly. It is the problem: parallel simultaneous load is not working... do you any idea about this? which task we need perform... or some suggestions?  thanks!

  • Connecting Two Power Supplies in one PC

    Hello there  :hypecrite:
    Will someone help me on how to connect two Switching P/S in one PC (If it's possible)?
    I tried using two P/S in my old PC and it's working just fine. However, the problem is that I cannot switch them on simultaneously because the one is connected directly to the motherboard and the other, I just used a simple switch to turn it on.
    Also, please check my P/S for this PC if it's OK.
    Thank you and more POWER!!!
     :hypecrite:

    Hello again :hypecrite:
    Thank you for your support guyz.  I would like to tell you that you are all correct.
    I think it's time for me to stop fooling aroung, experimenting things, too.  And to trust the verdors instead.  I looked for the psu brands that you all mentioned and it turned out my pockets could still handle such a cost, eventhough it costs twice as much as the psu that I have right now, but as long as it's dependable.
    And about the problem with my CPU's temperature that I posted last November 12, 2004 (MSI KT4A-V with S/PDIF out and Core center), AMD support center finally replied to me and told me that my temp is OK but not to go above 70C.
    Below is my inquiry to AMD and their reply:
    My inquiry:
    Dear Sir:
       I would like to ask what is the NORMAL operating temperature of Athlon XP 2400+ FSB 266 model 8?  
       When my PC is at idle, my CPU temp reading is 60C and during full load, it reaches to about 66C. It doesn't have any problems though (such as random reboot) but I'm a bit concerned of the temperature reading.  Some people say that it's a bit TOO HOT  for comfort. Still others say that it is OK.  What do you think?
      I have read your post on MAXIMUM operating temperatures of Athlon XPs but not the recommended NORMAL operating temperatures.
      And also when I turn  the BIOS CPU core voltage to AUTO mode the default is 1.575V. My friends said the minimal operating voltage of 2400+ is 1.650V. Is it OK to just leave it to default?
    Thank you very much
    Sincerely,
    Mark E. Guillem
    Philippines
    My PC Specifications:
    AMD Athlon XP 2400+ (Family 6, Model 8, Stepping 1), FSB266 256L2
    GlobalWin TAK68 CPU fan (dual fan, ball bearing 5200RPM max each)
    MSI KT4A-V (VIA KT400 chipset) BIOS ver. 2.3 date: 09092004 (with MSI Core Center)
    512MB DDR333 mem (2x256MB)
    Inno3D GeForce FX 5200 128MB with AGP8x w/ TV out
    80GB Maxtor 7200RPM 1x133
    40GB Seagate 5400RPM 1x100
    LiteON LDW 411S DVDRW 40x12x40
    LITE-ON XJ-HD166S DVDROM 16x
    Pinnacle PCI PCTV Rave TV tuner/capture card
    OS: Windows XP SP2
    The Reply:
    Dear Guillem,
    Thank you for contacting Asian and Pacific AMD Technical Support Centre.
    I can confirm that the temperatures ranges from 40° - 55° C  in moderate usage and with a higher workload around 65° C, but never over 70° C.
    What the correct voltage is concerned there are three models of the Athlon XP 2400+. If you have the CPU with the OPN AXDA2400DUV3C the
    voltage should be 1.60V otherwise it is 1.65V.
    It seems your system would overheat dangerously when set to the right voltage. I would suggest, you do check if the heatsink /fan is installed
    properly.
    You may find a different reading after upgrading your BIOS.
    * Please make sure to download the right BIOS version for your motherboard.
    Then, please, make sure that your processor Athlon XP 2400+ is configured in BIOS as follows:
    -          FSB speed to 133MHz (It is a bidirecctional bus, the full speed would be 266)
    -          CPU multiplier of 15x
    -          CPU voltage of 1.65V (1.60V if OPN = AXDA2400DUV3C)
    With these settings the clock frequency of the processor should be 2000 MHz.
    And finally you can test the CPU on another system to establish if the processor or the motherboard is responsible for the problem . If no other system is
    available to you then ask your retailer/reseller to test it for you.
    Given the case that the processor is faulty, we inform you that the PIB processors (box processors) have 3 years warranty, whilst OEM processors (tray processors) have only one year. In both cases the first year is given by the reseller and the PIB processors second and third years are served directly by AMD.
    If you have any further questions, please, do not hesitate to contact us again.
    Kind regards,
    Roberto Erler
    Technical Support Engineer
    Spain: 900 99 71 21 (Número Gratuito)
    France: 0800 908 621 (Numéro Vert)
    Germany: +49 89 450 53199
    Italy: 800 877 224
    United Kingdom: +44 1276 803 299
    Yesterday, I increased the CPU voltage to 1.60V (from the default of 1.575) and my temp reading was reduced to 50C at idle (from an idle of 60C) and at full load to 60C (from a full load of 66C).  I was not expecting this though.  I was expecting that my CPU's temp will increase further.  But this is what happened. I guess the RIGHT THING should be the RIGHT THING.
    Tomorrow, I will buy a new psu with the brands that you mentioned and I hope that my PC's stability and performance will increase further.
    Again thank you very much for your support and all.
      :hypecrite:

  • Connecting two USRP N210 to one computer

    Hi,
    I am trying to connect two USRP N210's to one pc. I want to simulate a real-time communication p2p link and I must use some blocks which are only available in MATLAB Simulink, i.e. I will have to configure one USRP as transmitter and the other as the receiver and in the middle I will put some Simulink blocks. My question is very basic. How do I get the operating system/ MATLAB, etc. recognize both of them, i.e. the two different IP addresses. I wonder I should use a network card with two slots or two normal network cards? or is there a simpler solution?
    FYI: I am very new to USRP's. 
    Thanks,
    Reza

    Dear Reza,
    Two possibilities : (a) use the so-called MIMO cable or (b) use two network interface cards.
    In both cases, USRPs are differentiated through their IP adresses.
    I'm not using Matlab so I'm not sure whether (a) works in this environment. Solution (b) will work.
    Also note that for real-time processing our experience tells that the
    quality of the NIC+driver makes a difference.
    Best wishes
    L

  • Connecting Two webapplication servers to one backend

    Hi Gurus,
    We are using MAM 3.0 version on SAP Netweaver 7.0. Can we connect one more Webapplication server  parallely with exising server to the samebackend. Two webapplication servers in parallely with one backend. Is this possible? could you please give us some documents so that it would be very helpful for us.
    Thanks in advance.
    Regards
    Satish

    Hi Domas,
    As pointed our by Holger, this is supported for inbound flows where your use case is to read (pull) some information from SAP into SharePoint. But use cases like reporting and workflow which publishes some items in SharePoint you cannot have the same ECC system.
    But if you intention is only for DEV landscape setup and want to save a VM image and still want to support reporting & WF scenarios, then you could also create a new client which is the copy of your existing clients in the same ECC system.
    Since logical port configurations are client specific you could practically connect same ECC system (but 2 diff clients) to 2 gateway systems.
    Thanks,
    Girimurugan

  • Connecting two BW systems

    Hi guys,
    I need at the moment to connect another BW system to ours. The Data should be extract everyday from our BW to the secound one.
    At the moment I have 2 points in my mind:
    - RFC User
    - Datasources
    Is there any other things that I have to keep in mind?
    Do you know maybe any "how to paper..." to this topic?
    Best Regards
    Erwin

    Hi Erwin,
    You can Access to one Particular Cube and provide access to only limited data by Authorization relevant fields.
    You can define all these settings in PFCG t-code.
    Create role and assign particular Users.
    You can use tabs like Menu/Authorizations/User to configure above settings.
    You can just get into PFCG t-code in your first BW system and see What kind of settings are there in the system?
    Regards,
    Suman

  • Connecting two mobile to the one bluetooth car kit...

    Is it possible to connect two mobile phones to the same bluetooth car kit at the same time?

    I dont think its possible, i may be wrong, but imagine if both phones were connected to the car kit and they both got a phone call, there is no way it would work as it would not know what phone to connect.
    So i dont think its possible.
    My posts are my opinion and in no way the direct views of Nokia.
    If my posts are helpful, please give me some KUDOS using the green star on the left.

  • Connecting two R3 systems to BW

    <i><b>Current State:</b></i>
    We currently have two R3 test systems defined as source systems  to our BW test system.   All the infosources, infopackages and process chains are connected to only one of those R3 test systems.
    <i><b>Desired State</b></i>:
    What I want to do is "copy" all these definitions to the second test system creating a parallel set of Infopackages and Process chains that pull from the second test system.
    Is this possible to do via an SAP supplied program or do I have to do each one manually?

    Hi:
    Create a new Entry for the new R/3 System in BW QAS:
    RSA1
    Tools
    Mapping of Source System ID
    DELETE the OLD Mapping that you already have with Old R/3 System.
    Now,
    1) COLLECT all the InfoSOurces including Infopackages that you need and Transport them in QAS. If you chose this step, make sure yuo tell BASIS not to move them to PROD.
    2) Re-IMPORT some of your old Requests that have those InfoSource/Data SOurce. This may not work because you likely mixed up your transports. Then, I would go with Option-1.
    When you complete this step, you will have duplicated all you old R/3 Data SOurces to NEW R/3.
    P-CHains have to manaully COPIED. Here, after Copying, change the InfoPackages to new R/3 system.
    U.P. Chamarthy
    Message was edited by:
            U.P. Chamarthy

Maybe you are looking for

  • FAIL_OVER in jdbc url

    Hello, Recently one of db database node was down and our application did not connect to another node as per the below URL because we have configured FAIL_OVER=ON. <connection-url> jdbc:oracle:thin:@(DESCRIPTION=(LOAD_BALANCE=ON)(FAILOVER=ON)(ADDRESS=

  • Connection Reset by peer errors in Weblogic

    Hi, The weblogic server is throwing the following error , Any inputs to solve this will be highly appreciated. ####<Feb 2, 2006 3:43:11 PM CST> <Error> <HTTP> <xdaawsf001> <AWSServer> <ExecuteThread: '21' for queue: 'weblogic.kernel.Default'> <<WLS K

  • ISchedulerTask - Access Resources

    Hi guys, does anyone of you know how to access a resource from an ISchedulerTask's "run" method? I want to access an XML-file that contains some configuration data. The XML-file is in the same PAR-file as the ISchedulerTask. Although they are in diff

  • Mail 4.2 again - and more

    The plot thickens, I'll try again, even though there was no answer to my rather general first posting. My Mail-application refuses to read/transfer e-mails of all classifications (personal, group + spam), I also lost the JUNK mailbox. I've reset pref

  • No Audio Overviews: Refresh does not fix

    Hi All, I recently transferred a project between two computers and the audio overviews got lost in the process. That is, the regions in the arrange window to not show any waveforms. I selected all of the audio files in the bin and hit refresh overvie