hi, all, what should I fill in the function group and authorization group and other contents required? thank you in advance, I really confused with it.

Hi Dawson,
Go to SE11, give the table name and click on change. Then Go to utilities--> Table
maintenance generator.
In the table maintenance generator screen, we should give Authorization Group (to whom this table maintenance should be allowed),
Function Group name (Function Group name can be same as table name or it should start with 'Z' or 'Y'),
Maintenance type can be one step or two step, usually we will create with one
step. we should give maintenance screen number. After clicking on create button,
a table maintenance generator will be created.
To check it go to SM30 . In SM30, we find display, Maintain options.
Function Group: We need to provide a Z function group name, so that SAP generates an module pool program in the background for the table maintenance.
Authorization Group: To which group of users this table maintenance should be allowed (Eg: MM, SD etc).
Regards,
Ramesh

Similar Messages

  • Problem in creating table maintenance generator for 61 fields in table

    Hi Experts,
    I am facing problem in creating a table maintenance genarator for a ZTABLE which has 61 fields
    i am using below details whicle creating the TMG
    in Maintenance screen
    i am giving maintenance type as two step
    Maint screen no overview screen 2
                              single screen        3
    Dialog Data Transport details
    Recording routine    standard recording routine
    but it is giving following error
    screen SAPL<ZTABLE NAME>    0003 could not be generated
    In DYNPFIELD_ATTR mandatory field LINE has no value
    please let me know how to sort out these errors.
    Is there any limit on the number of fields for which we can create table maintenance generetor.
    Thanks a lot in advance
    Sudipto

    Hi Sudipto,
    There is not limit to the number of fields of the Table which can be used in TMG for generation. But, from the usability point of view this will horrible.
    I created a Z table and added 64 fields and was able to generate the TMG with the screens perfectly. So, I guess there should not be any problem.
    Well, have a look at the Function Group. I guess the screen numbers are already used by some other screens. You can set the system to propose freely available screen numbers from the pool.
    Also, check whether proper authorization is assigned or not.
    And if nothing is working, you can degenerate all the generated screens and then can have a new regeneration of it.
    Hope these tips will work.
    Thanks,
    Samantak

  • Create a Maintenance view for table T500P

    Hi Experts,
    We have a requirement where customer want an additional field in table T500P and for the same a custom maintenanve view has to be created.Moreover, If there is any update insert or change in the ZView/Ztable the same should be reflected in standard table T500P.
    Steps already taken :-
    We have created a ztable (copy of T500P ) and add the required custom field to it.
    We have also copied the view i.e V_T500P to our custom view and also use base table as T500P .
    We also create a foreign key for PERSA in Ztable and use T500P as check table for that with cardinality 1:1.
    To update the MOLGA & BUKRS field data in ztable we have set both the field as a primary key & create a foreign key with check table T500L & T001 & cardianality as 1:CN for key fields.
    In custom maintenance view we have set the realtionship of ztable t500l & t001 with the base table T500P.
    Now, if we are trying to maintain the view only T500P table is getting updated and Ztable is updated with only PERSA value.
    Please provide some directions for the resolution of this issue.
    Thanks,
    Pooja Goel.

    Scheduler007 --
    The view you selected by clicking File > Options > Project View is the default view for every new project you create from a blank project template.  This is a global option, so setting it from the checked out Enterprise Global file serves no purpose. 
    When you select a view as your default view, you will see that view applied to the blank project that is opened when you launch Microsoft Project 2010, and you will see it applied if you create new blank projects.  If you create enterprise templates for
    people to use in your organization, you should simply apply the view to the template that you want as the default so that users will see this view immediately when they create a new project from the template.  In addition, if you apply a view to an open
    project, close and check in the project, and then reopen the project, you will see the last view applied in that project (as Guillaume correctly points out).
    Beyond this, there is no method possible for the Project Server administrator to specify a default view for the Microsoft Project application used by the project managers in your organization.  This is an option each PM must set.  Hope this helps.
    Dale A. Howard [MVP]

  • Problem in Selection Conditions Maintenance View

    Hello Gurus.
    I've created a maintenance view for a ZTABLE, in this maintenance view in TABLE/JOIN Conditions i defined a relationship beetween my ZTABLE and SKAT.
    Untill this point its fine. But when i go to the tab of selection conditions, there already there two automatic conditions. And i can't edit these conditions.
    Why this is happening?? Anyone knows??
    Thanks in advance

    Hi There,
    Those are the Primary fields or key fields sharing the common data,, This is required to maintain the data consistency. SAP's major strength is its data integrity...
    You will not be able to edit primary keys since these values are maintained in several other tables too. changing at one place and keeping it as is in another table lead to data inconsistency.
    let me know if you have further queries.
    don't forget to rward pionts if found useful.
    Thanks-

  • Need to create maintenance view for a custom infotype

    A custom infotype 90XX is created. The data cannot be modified or created through PA30 in this infotype. Through PA 40 actions only we can create/change the record/data. We have created some 1000 records in it. Now can we create a maintenance view for the infotype so that we can create, delete or change the data in the infotype as and when we want.

    Hi,
    pls chk dat u have maintained the 'Infotype Charecteristics' and 'Technical Attributes' correctly.
    thanks,
    teja.

  • Creating a Maintenance View Table on SE11

    Hi, Experts.  I want to create a Maintenance View Table on SE11 (View option on SE11 and then selecting Maintenance view from the View Type List).  Is there anyone who have a document that will be able to help me create this table or pointers that will help me.
    Thanks for your help.
    Regards

    hi,
    steps are
    Goto SE 11.
    Choose the radio button of Views, give the view name and create.
    Enter the short description and table names for which u want to create view.
    Select the 2nd table-name field and click on relationship button.
    Then goto view fields tab.
    Select the table name and the fields u want to display.
    Save and activate.
    please see this
    steps  to create a view

  • How to create a maintainance view for a table.

    Hi All,
    Can anyone explain me how do we create a maintainance view for a table?
    Also, what access is required to create the view.
    Is it true that for SAP tables we cannot create a maintainance view?
    Appreciate any help on this.

    Hi
    Can anyone explain me how do we create a maintainance view for a table?
    <i>
    You can use the SE11 menu option 'Utilities-->Table Maintenance Generator' or you can use transaction SE54.</i>
    also check
    <i>http://help.sap.com/saphelp_nw04/helpdata/en/38/81c1351181b73fe10000009b38f839/frameset.htm</i>
    http://help.sap.com/saphelp_nw04/helpdata/en/38/81c1351181b73fe10000009b38f839/frameset.htm
    Regards
    krishna
    <i>Note: Award Points if helpful. Thanks</i>

  • Reg :-maintain a table maintenance view for the z table.suggest me the code

    i have question.i have created a z table related to pp module.the requirement is to maintain {table maintenance view} for this z table.how could this be done.can any one suggest me the code for this?

    Hi ,
    We have a lots of queries on table maintainance creation in the forum posted and replied to.Pls have a look at it first.
    In se11 -> change mode of the ztable -> goto -> utilities -> table maintainance generator -> click on it...
    it will give a new screen-> enter the required details like function group , authorisation(use &NC& or leave it blank if you dont know)  and screens
    2 step and 1 step means=> number of screens displayed in maintainace
    if step1 is selected then we have a screen which will be like a table control for data entry.........
    for step2 we have a table control screen and a more detailed individual field display as second screen
    click on the button 'find screen numbers' so that system automatically proposes the screen numbers
    after which click on the "create" button and follow the required instructions/messages
    once done go to SM30 enter the table name to check if maintainance has been created properly
    Hope it helps,Pls check and revert
    Regards
    Byju

  • Maintenance View for checktables

    Hi,
    I had a scenario where I had to create around 30 check tabels(Z Tables). I have to create maintenance view for these tables. Instead of creating 30 transactions is there a better way to do this.
    If I create a report for this purpose with radio buttons in the selection screen for each table, can I call transaction SM30 and pass the table name, skip the first screen and do the entries.
    Thanks,
    Viswas

    Hi,
    There is no need to go for call transaction
      CALL FUNCTION 'VIEW_MAINTENANCE_CALL'
          EXPORTING
            ACTION      = 'U'
            VIEW_NAME   = 'ZTAB'
          TABLES
            DBA_SELLIST = IT_RANGETAB
          EXCEPTIONS
            CLIENT_REFERENCE                     = 1
            FOREIGN_LOCK                         = 2
            INVALID_ACTION                       = 3
            NO_CLIENTINDEPENDENT_AUTH            = 4
            NO_DATABASE_FUNCTION                 = 5
            NO_EDITOR_FUNCTION                   = 6
            NO_SHOW_AUTH                         = 7
            NO_TVDIR_ENTRY                       = 8
            NO_UPD_AUTH                          = 9
            ONLY_SHOW_ALLOWED                    = 10
            SYSTEM_FAILURE                       = 11
            UNKNOWN_FIELD_IN_DBA_SELLIST         = 12
            VIEW_NOT_FOUND                       = 13
            MAINTENANCE_PROHIBITED               = 14
            OTHERS                               = 15.
        IF SY-SUBRC <> 0.
          MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
             WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
        ENDIF.
    aRs

  • Maintenance View for custom table with foreign key relationship

    Hi Folks,
         I have created a custom table with foreign key relationship with other check tables. I want to create a maintenance view / tablemaintenance generator. What all things I need to take care for the foreign keys related fields while creating the maintenance view / tablemaintenance generator.
    Regards,
      santosh

    Hi,
    You do not have to do anything explicitely for the foreign key relationships in the table maintainance generator.
    Create the table maintainance generator via SE11 and it will take care of all teh foreign key checks by itself.
    Regards,
    Ankur Parab

  • Unable to resolve error while creating a maintenance project for SMD

    Hi,
    I am getting an error when I try to create a maintenance project for SMD 331- SMD 341 - SMD 351 systems.
    ( SMD 331- Development, SMD 341- Test, SMD 351- Production ) SMD is 4.0 upgraded system.
    Detailed description of the problem:
    In SOLAR_PROJECT_ADMIN, I select a newly created project
    GS_SMD3513 and in tab 'System Landscape', go to tab 'Change Requests', here when I do consistency check
    I get following errors
    1. 'No consolidation system found for SMD-331 (project  GS_SMD3513)'
    2. Message from function module /TMWFLOW/CHECK_PRJ_CONS: No export system for SMD-351
    3. Error reading information for number range object /TMWFLOW/D
    The transport route between SMD331- SMD341- SMD351 is available as any transport request created in SMD 331 can be successfully imported to SMD 341 and SMD 351.
    I need help to resolve these errors.
    Edited by: Dipti Sawarkar on Jan 7, 2008 6:41 AM

    Hi Patmol,
    Have you tried to go to the previous or next timesheet and then navigate with the "previous period" or "next period" to the timesheet in question.
    Also have you tried to open it using a delegation session?
    Hope this helps,
    Guillaume Rouyre, MBA, MCP, MCTS |

  • How to create a help view for a customized error message

    Hi all,
    Can you guide me how to create a help view for a customized error message, we need to put some suggestions in it so that user can can resolve this issue with this guide. ( the short text is too short to describe all situations via TC:SE91)
    Thanks very much!
    Bruce, Wen

    Hi Bruce,
    Could you brief your concerns again.
    Why don't you maintain long text in message class for long description.
    Regards,
    Ranjith N

  • How to create a special view for sharepoint list A and deploy this view to specific user personal view?

    How to create a public view for sharepoint list A and deploy this view to specific user personal view? Is that possible OOTB?

    Views cannot be exported or moved. Can you elaborate your requirement?
    --Cheers

  • Create a defaut view for the MS Project Server 2010 client

    Dear Forum,
    how can I create a defaut view for the MS Project Server 2010 client?
    I saved a template and set a default view under File -> Options ->Project View. I also did the same in the checked-out enterprise global. If I then close the client and re-open it my default view changes back again to the previous one (not the view
    I set as a default view).
    What explains this behaviour and what can I do? Any hints?
    Thank you very much for your help!

    Scheduler007 --
    The view you selected by clicking File > Options > Project View is the default view for every new project you create from a blank project template.  This is a global option, so setting it from the checked out Enterprise Global file serves no purpose. 
    When you select a view as your default view, you will see that view applied to the blank project that is opened when you launch Microsoft Project 2010, and you will see it applied if you create new blank projects.  If you create enterprise templates for
    people to use in your organization, you should simply apply the view to the template that you want as the default so that users will see this view immediately when they create a new project from the template.  In addition, if you apply a view to an open
    project, close and check in the project, and then reopen the project, you will see the last view applied in that project (as Guillaume correctly points out).
    Beyond this, there is no method possible for the Project Server administrator to specify a default view for the Microsoft Project application used by the project managers in your organization.  This is an option each PM must set.  Hope this helps.
    Dale A. Howard [MVP]

  • Hi all, i'm new and facing a problem while creating a new file for Xcode. I can't select the box "with XIB for user interface" if the subclass is "UIViewController".this problem happen after i upgrade Xcode to 4.6 version.Appreciate for any help rendered.

    Hi all, i'm new to Mac book & Xcode. I'm learning and facing problems while creating a new file for Xcode. Before i upgrade the software, i have no issue to create simple steps in apps. After upgrade Xcode to 4.6 version, i'm facing lot's of issue eg.
    1) "the identity "iphone developer" doesn't match any valid certificate/ private key pair",
    2) can't select the box "with XIB for user interface" if the subclass is "UIViewController"..
    Appreciate for any help rendered.

    Mikko777 wrote:So what is the best?
    I wouldn't judge. I've been to Arch for a week, you know? But as said, it's VERY close to it.
    What I dislike after a week is makepkg not handling dependencies automatically (which would be overhead, so probably not appropriate).
    Mikko777 wrote:Also theres KDEmod for modular kde, dunno if its for 64 bits tho.
    Don't actually need that as said ... I see no real benefit of having that other than not beeing a KDE user or having Gentoos useflags.
    Mikko777 wrote:PS:You produce a lot of text and welcome smile
    Yeah. Wonder why I'm still employed? So do I ...

Maybe you are looking for