Synchronize a DO trough a 6534 board with an AI trough a 6115 card

What is the better mean to synchronize a 6534 board (Digital output, master card) and a 6115 board (analog input, slave card) trough the RSTI cable.
In the help, I see that two different VI may be useful: RTSI Control and Route Config.
Is it possible to do the job with only RTSI control set for the 2 cards?
I do not own the card yet and have to know if they can be easely synchronized before buying them !!
Laurent

Hello;
The can definitely be easily synchronized through the RTSI bus.
To accomplish that task you need to make a call to RTSI Control.vi which will route the clock of the 6534 board to one of the RTSI lines, and also make a call to Route Signal.vi which will route that same RTSI line you routed before to be the Scan Clock signal of the 6115 board.
The difference in between those two VIs is only the fact that the RTSI Control.vi is used withthe digital boards only and the Route Signal.vi is used with the MIO boards only, but their functionality is pretty much the same.
Hope this helps.
Filipe A.
Applications Engineer
National Instruments

Similar Messages

  • Synchronize multiple tasks and multiple boards with X-series USB devices

    Hi all,
    I am trying to figure out how to synchronize multiple tasks across multiple X-series USB boards (6353, to be precise). 
    I have to run a digital output task AND an analog output task on each board.  All four tasks (the DO and AO on Board 1, and the DO and AO on Board 2) must be synchronized.
    I know how to synchronize multiple tasks on a single board.  I've been doing that for years.  That works fine.
    I know how to synchronize a single task across multiple boards (say, a DO task across 2 different boards).  That works fine too.
    For the life of me, I can't figure out how to marry the two.  Everything I've seen, all of the examples, etc. assume you want to do one or the other, or that you have a RTSI cable available.  Are there any examples out there that synchronize multiple tasks across multiple USB boards?
    I tried exporting the AO clock signal from my master AO task to PFI12, and then using the signal on PFI12 to as the clock source for the remaining tasks (Dev1/PFI12 physically connected to Dev2/PFI12, and Dev1/PFI12 set as the clock source for Dev1's DO task). 
    I have also tried setting Dev1/aoSampClock as the source for Dev1's DO task.
    Under both configurations, I invariably get error -89137 when I try to start the tasks -- required resources (PFI12) in use by Dev1/do/SampClock.  I understand what the error is telling me.  What I don't understand is why I'm receiving this error when I don't have any of my tasks configured to use the DO Sample Clock.  It seems as though it is not possible to export a clock signal to a PFI line and simultaneously run a clocked digital task, even if the clock source for that task is specified as something other than the DO Sample Clock?
    So, my question is, is it possible to do what I want to do?  And if so, how do I do it?  How do I configure a common clock source across multiple tasks running on multiple USB boards?
    Hoping for insight from those wiser than I...
    Diane
    Solved!
    Go to Solution.

    Update:  I decided to try using a counter as the source clock.  One cannot use counter 0 to accomplish this, but it does appear to work with counter 1.
    I'll take what I can get.  Fortunately I have two spare counters.  (Yes, I'm running counter tasks too -- 6 of them -- but they don't have to be synchronized.)
    I have to add both digital and analog input tasks as well -- all synchronous with each other, but not with the output tasks since they'll be running at different sample rates.  I hope I'm able to use a counter as the source clock for those as well.
    My head aches.

  • How do I set my 6534 board to read in at port B, line 2?

    Hi All,
    After many trials, I still could not
    get my 6534 board to read in data
    at port B, line 2, or any other port or line.
    I thought I pick port 1 and line b'10, or port
    1 line 2, but I still cannot do this.
    Could you guys help me out?
    I am using the Buffered Pattern Input.vi.
    I just couldn't understand how to use
    the port list control.
    Thank you in advance.

    Hello Van626,
    Check the manual below for control lines connections and configurations. It is important to know which protocol you will be using to communicate with your external device. i.e. Handshaking, pattern I/O...
    Chapters 2 and 3 will give you a lot of information on how to configure your board.
    http://www.ni.com/pdf/manuals/371464d.pdf

  • How to import 6602's counter output to PFI3 of the 6534 board?

    Dear friends,
    I have the following problem:
    I am trying to import the output of one of the counters of the 6602 board (counter 4) to
    the REQ2 (PFI3) line of the 6543 board (please see the VI attached). But I do
    not see any signal on the PFI3 line though the VI runs without errors.
    The situation is the same if I connect output of the counter to the PFI3 directly in the "Connect Terminals" VI instead of connecting it via PXI_Trig4 line.
    I need your help to understand why is it so and how can I accomplish the
    "import" task.
    Thanks in advance!
    Attachments:
    counterImport.vi ‏28 KB

    Hi Andrew,
    You are absolutely right - there should be PFI20 instead of PFI26.
    It works now. Thank you!
    .....I hope you can give some ideas with regard to the following problem:
    In a program I used four 6602's counters (counters 0-3) to generate single trigger
    pulses on the backplane of the PXI.
    It worked fine.
    Now I want to incorporate the fifth counter into the program (counter 4) to
    generate a finite pulse sequence on the PFI3 line of the 6534 board.
    And I can not do this.
    Code example is in the VI attached.
    When I try to run this VI it gives error:
    Error -89137 occurred at DAQmx Connect Terminals.vi:4
    Possible reason(s):
    Specified route cannot be satisfied, because it requires resources that are
    currently in use by another route.
    Source Device: TimingIO
    Source Terminal: PFI36
    Destination Device: TimingIO
    Destination Terminal: PXI_Trig0
    Required Resources in Use by
    Source Device: TimingIO
    Source Terminal: PFI20
    Destination Device: TimingIO
    Destination Terminal: PXI_Trig4
    I do not understand why it happens and how to correct this....
    Thanks!
    Attachments:
    counterImport 2.vi ‏79 KB

  • How do I use AT-A2150 board with LV 5.1 ?

    Hi,
    I'm trying to find a way of using my old AT-A2150 board with labview 5.1.
    I followed some posting tips from NI knowledgeBase (1JACI8U3 and 1JO8TB2O
    ) and installed NI-DAQ 4.9.
    The only problem is that now I'm getting broken arrows on my DAQ VIs. My
    platform is Windows NT 4.
    Any help would be greatly appreciated.
    Eric

    Use a Mini DisplayPort adapter for that monitor type.
    (59966)

  • Can we replace an old serial board with a new one found available on your site?

    So.. we are using Lookout 5.0 to operate a plant, and we have a PCI SERIAL RS 232/485 ISOLATED 2 PORTS board, with the code 185726C-02 printed on that board, which is used to comunicate with some solenoids modules. I search your site for a replacement for that board, and I found the PCI-8433/2 board which seems to be compatible. Question: is it ok to use this board instead the old one with Lookout 5 if we update the NI SERIAL drivers from your site?
    Thanks in advance ..
    Eddie Zack

    Make sure the site folder created by iWeb is named exactly the same as the site folder currently on the server.
    OT

  • Integration of OBIEE Dash Boards with BPM Process

    Hi ,
    Could you please help me in integrating OBIEE Dash Boards with BPM . I thought of using 2 ways :
    1) Integrating OBIEE with ADF First and then Integrating ADF with BPM . Its a long process but any other way if any one can help me .
    2) Integrating OBIEE with BPM directly by generating webservices . but i couldnt get any options to generate the webservices for OBIEE .
    Can anyone please guide me on this .
    Thank you,
    Sashank P.

    Check these links may help you.
    http://docs.oracle.com/cd/E21764_01/bi.1111/e16364/actions.htm
    http://gerardnico.com/wiki/ide/eclipse/eclipse_how_to_consume_a_webservice_with_wtp#the_result
    http://gerardnico.com/wiki/dat/obiee/web_service

  • How to use 2 1409 boards with sony xc55 to acquire 2 images simutaneously

    We want to use two 1409 boards with two sony xc55 cameras to acquire two images simutaneously. From the attached files, you will find what I have done and the problems. I just followed the example program from you. But it doesn't work well. Could you help me? thank you very much.
    Attachments:
    What_happen_now.doc ‏25 KB
    XC55_Asynchronous_Reset_ExampleTwo_Cameras1.vi ‏265 KB

    Kobel,
    Both cameras are being triggered at the same time, and both boards are aquiering the image at the same time. The problem you are seeing is related to copying the correct image.
    The IMAQ driver is not currently multithreaded, therefore your second copy opperation can not execute until your first one is done. The trouble is that you have the immediate terminal set to false which forces the copy to wait for the next available image before returning.
    Since the second copy does not execute until the first one is complete, it will consider the frame that just passed as old and wait for the next available frame.
    The quick solution is to change the immediate terminal to true on both copies. The best solution depends on your entie application. You may want to re
    ad this application note on Ring Aquisitions for ideas.
    Regards,
    Amaury Rolin
    NI Applications Engineer

  • Where can I find commands for wireless key board with my Ipad?

    how do I find a command list for using my apple wireless key board with my Ipad?

    you will have to power off the wireless keyboard...or go into your settings and turn off the bluetooth when you aren't using it.
    the default for hte ipad is to only have one keyboard at a time. And if your ipad senses a blue tooth attached, your onscreen one will not be visible.

  • Synchronize WF LOCAL tables in R12 failed with error  :ORA-14501 object is

    Hi All,
    In our R12 enviroment "Synchronize WF LOCAL tables" conc program failing with :ORA-14501 object is not partitioned.
    Tried solution as per doc id . 433280.1 -- Partitions in Workflow Local Tables are Automatically Switched to NOLOGGING . But no success.
    Please help.

    Hi Hussein,
    Thanks for reply. Please find the below details.
    RELEASE_NAME
    12.1.3
    BANNER
    Oracle Database 11g Enterprise Edition Release 11.2.0.3.0 - 64bit Production
    Linux **** 2.6.18-128.el5 #1 SMP Wed Jan 21 08:45:05 EST 2009 x86_64 x86_64 x86_64 GNU/Linux
    Conc Req Log file
    Application Object Library: Version : 12.0.0
    Copyright (c) 1979, 1999, Oracle Corporation. All rights reserved.
    FNDWFLSC module: Synchronize WF LOCAL tables
    Current system time is 19-JUN-2012 05:49:20
    **Starts**19-JUN-2012 05:49:20
    **Ends**19-JUN-2012 05:49:20
    ORA-14501: object is not partitioned
    Start of log messages from FND_FILE
    End of log messages from FND_FILE
    Executing request completion options...
    Output file size:
    0
    Finished executing request completion options.
    Concurrent request completed
    Current system time is 19-JUN-2012 05:49:20
    ---------------------------------------------------------------------------

  • MSI working on a fix for using SB chips on p67/z86 boards with new IB BIOS?

    I've got an MSI Z68A-GD80 B3, I updated to the version 20.0 BIOS which supports IB chips, but I'm currently running an i7 2600K. My machine seems to be stable with the new BIOS (better than previous BIOS versions actually), but for whatever reason when I went to the v20.0 BIOS I lost all ability to overclock. The only option which shows up in any BIOS menus is AUTO. No multiplier adjustment for the CPU, no V adjustments for anything, no RAM adjustments, etc...in fact the closest I can come is by adjust whether the RAM is running XMP profile or not. Everything else appears normal, but for all intensive purposes I've given myself an H variant board with no OC options by updating the BIOS.
    So, my question is, since every other MB manufacturer seems to have figured out how to support both IB and SB chips on z68 systems why hasn't MSI? Is this support forthcoming or do I need to invest in a new MB or a new CPU just to be able to OC again?

    No bashing intended, just tellling it like it is. Almost everyday, if not everyday, there are threads of users bricking boards flashing Ivy UEFI/BIOS's when an Ivy is never to be installed. Most of these are user error not reading the SOP, or not having a bootable USB stick, or whatever. Most flashing isn't even necessary unless a specific function or feature requires it. Too many are 'flash' happy for no reason at all.  MSI's goal 'may' be to develop and release a 'universal' UEFI/BIOS that works decent for Sandy or an Ivy. These 'compromises' often are not ideal. Try the last official revision xmad mentioned, or try the Beta for the (G3) I linked.
    Quote
    So, my question is, since every other MB manufacturer seems to have figured out how to support both IB and SB chips on z68 systems why hasn't MSI? Is this support forthcoming or do I need to invest in a new MB or a new CPU just to be able to OC again?
    This 'question' itself is somewhat bordering on 'bashing', so I think it has been satisfactorily answered. Further comments about it are just going to head towards an argument. You have the link to MSI Technical and the (G3) Beta thread.

  • How to synchronize Address Books and Calendar Books in Mavericks 10.9.2, I am unable to synchronize my Address and Calendar Books informations with my iPhone 4 via iTunes

    Since I updated my MacBook Pro's OS X version 10.6.8 to Mavericks 10.9.2, I am unable to synchronize my Address and Calendar Books informations with my iPhone 4 via iTunes.  What do I need to do to update these data ?

    I cannot synchronize the Address Book and Calendar data, even by means of iCloud or similar servers.  It appears these data are not selected automatically during synchronization. How can one select Address Book and Calendar Book in Mavericks for synchronization ?

  • How to use a PCI-DIO-32HS board with macintosh C++

    How can I run the PCI-DIO-32HS board with code from CodeWarrior for a Macintosh G3? The current drivers (V4.8) with Mac C++ support don't support this board.

    Here is a list of supported compilers with NI-DAQ 4.9.4 or earlier found on the www.ni.com/support website search
    Apple MPW 3.3.x
    Mainstay VIP-C 2.0.x
    Metrowerks CodeWarrior Pro 1
    Staz Software FutureBASIC 2.x.x
    Symantec THINK Pascal 4.0.x
    Symantec THINK Project Manager 7.0.x Symantec Project Manager 8.0.x
    Zedcor FutureBASIC 1.0.x
    If are programming in a different programming environment you will have to use Register Level Programming (RLP). For more information on RLP you can visit www.ni.com/support/daqsupp.htm and look under the Resources for register level programming link.

  • LV acquire the print information from the embed board with Linux system through serial port

    I want to acquire the print information by LV from the embed board with Linux system through serial port, like the window hyperterminal tool?
    I try to use VISA serial config function to achieve it ,but lost and prompt that is error like attachment.
    I can't sure that my idea is reasonable.
    help me
    thanks a lot!

    I ended up finding the answer to my problem. After pointing a client directly at one of the DPS systems, I saw the following error in the logs:
    [27/Jul/2009:17:11:47 -0400] - OPERATION  - INFO  - conn=3688 op=4 BIND RESPONSE err=12 msg="The server is not configured to pass through control 1.3.6.1.4.1.42.2.27.8.5.1" etime=0After adding that control OID to the allowed-ldap-controls, I could login via password auth. Adding this control also allowed for password changes to work from a client system.

  • Is the Nexys2 board (with spartan 3e FPGA) compatible with the FPGA module

    Hi my name is DIego and I was wondering if anybody here knows if the NEXYS 2 board (with spartan 3e FPGA) from DIGILENT is compatible
    with the LABVIEW FPGA module.
    Thanks
    Digilent is also the Manufacturer of the SPARTAN 3e STARTER BOARD

    Diego:
    The NEXYS 2 is not officially supported, but if you'd like to try it, you can attempt to follow the guide for the Spartan 3E here (substituting your NEXYS 2 for the Spartan 3E).
    Again, the NEXYS 2 isn't officially supported, so if it doesn't work like the Spartan 3E starter kit board, then you won't be able to use LabVIEW FPGA with it.
    Good luck!
    Caleb Harris
    National Instruments | Mechanical Engineer | http://www.ni.com/support

Maybe you are looking for

  • How to delete a symbol with a click of a inside button

    Hello, I have this Symbol with a button inside. I want to click on this button and delete the Symbol. I have the code below but it doesn't work. sym.getComposition().getStage().getSymbol("vitrine_content").$("cachedarmes_movie").delete Symbol(); if I

  • Schedule report to multiple Inbox errors

    XI R1 I've got users that need to schedule a job to goto multiple inboxes. When the report runs it fails with this message recipient error. no destination objects could be found (possible empty or invalid user or user group, or security restriction?)

  • Content-Lengh Header Missing in Http Response

    Hi folks,           Our application uses JSPs and Servlets. To solve a TCP level problem, we would like to ensure that each response sent from the WebLogic Server includes a content-length header. All the pages are dynamic and therefore we cannot exp

  • Problem with logic 7.2 and digi002 with latency

    Hello, I have a G4 mac mini with Logic Express 7.2 and ProTools 7.1. and a Digidesign Digi002 Rack. The probem I am having is that when I set my buffer sixe in PT everything is fine. I can set it down to 64 or even 128 with no latency. But when I set

  • How to continuos sync database to Azure database?

    1. We need to migrate database on Azure SQL Server  2. Provide continuous syncing between on premise database to Azure SQL Database   Database size is 500GB What should I do? Can I use Azure Sync feature? its in preview mode. Please suggest me any so