2 Infopackages missing after installing Process Chain BI 7.0 TechContents

Hi,
I have installed the process chains for BI 7.0 Technical Contents and when trying to run a check on the process chains, I got an error on these 2 infopackages which were not installed from the BI 7.0 technical content packages:
0PAK_472D695A0ZS3DWVBA4H1OO9A6
0PAK_472D4SFZXKU0L9FF8UESP72F2
Anyone know if these 2 infopackages are needed and if yes, where are these infopackages loading data to?
Thanks,
Anthony

Please upgrade the system to SAP_BW SP16
There is a work-around for activating these two process chains if you don't want to upgrade the SP Level to SP16.
Apply SAP Note No. 989927 and run the installation report RSTCC_ACTIVATEADMINCOCKPIT_NEW. Please follow the manual steps mentioned below.
Please execute the transaction RSPC (Network Display). Change to 'Edit' mode. Go to the Main Menu.  Double-click on Query Runtime Statistics - Init (0TCT_C0_INIT_P01) and right-click on 'Load Data (0TCT_DSA1_INIT_DATAMART)' and select 'Remove Process' option in the Context Menu. Repeat the same procedure for the subsequent process 'Create Index (Generated from Loading 0PAK_472D4SFZXKU0L9FF8UESP72F2) and remove the links related to it as well. Then Activate the Process Chain 'Query Runtime Statistics - Init (0TCT_C0_INIT_P01)'.
Go to the Main Menu. Click on Query Runtime Statistics - Delta (0TCT_C0_DELTA_P01) and right click on 'Load Data (0TCT_DSA1_DELTA_DATAMART)' and click 'Remove Process' in the Context Menu. Remove all links leding to it as well. Then Activate the Process Chain 'Query Runtime Statistics - Delta (0TCT_C0_DELTA_P01)'.
Then Schedule the Process Chain 'Query Runtime Statistics - Init (0TCT_C0_INIT_P01)'. This will take care of the Process Chain 'Query Runtime Statistics - Delta (0TCT_C0_DELTA_P01)' as well.
Note 1134944 - BIAC: Problem in Process Chains BI_CONT SP8, SAP_BW < SP16
Hope it Helps
Chetan
@CP..

Similar Messages

  • HT4477 One complete family file missing after installing iPhoto 11 ??

    One complete family file of photo's is missing after installing iPhoto 11. Installation went smoothly, and all other files complete. Have checked thru entire photo lists, including photo list at the top. Found two photo's in that should have been in that photo list that were downloaded 2 months prior to installing iPhoto 11. I keep files of each family branch on left side iPhoto window. Only the one file is missing. ????

    I meant folder. Have 6 kids, and to keep track of each family quickly, I set up folders on left side of iPhoto. All others are there.

  • Libm.so.1 and other libraries, missing after install

    I'm running into problems because libm.so.1 and some other libraries are missing after install.
    - Solaris 8
    - Not an LD_LIBRARY_PATH issue, I did a full FIND and it did not show up.
    Any information as to why these libraries may have gone missing and what I might do to get around this problem would be appreciated.
    Thanks,
    -Ken

    Cause: The installation which caused this symptomology was based on a boot from a downloaded ISO designated "Installation CD" (Solaris 8). Booting from, and installing based on this CD caused a incomplete installation, with many libraries missing.
    Solution: Just by chance, on a re-installation attempt I booted from 'Software 1 of 2 CD" (Solaris 8). Installation based this boot yielded a complete installation - no libraries missing.
    Thanks for the suggestions,
    -Ken

  • Error in installing process chain from Business Content.

    Dear Experts,
    I have successfully installed the Technical Content from Business Content and now trying to install Content Master Data process chain for info package for the same but its showing error.
    <b>Technical Name for Process Chain : 0TCT_MD_C_FULL_P01</b>
    Error after instaling from BI Content : <b>Process AND has no predecessor.</b>
    Finally, while checking in RSPC it comes the name of Process Chain but its not showing anything.
    Also, one more thing is I am trying to install in development system and if that occurs successfully than transport to production as production directly don't wanted to do.
    Thanks in advance.
    Regards,
    NJ

    ithink u have not activated the process chainafter creating the process chain u might have saved it with out activating the process cahin so that is the reason why it is showing name name but northing in the chain first activate the cahin then it iwill show
    try this
    Aravindan pagadala
    satyam

  • Infopackage laoding scheduled in Process Chain and events involved

    Hi BW-Experts,
    Till now I was loading a infopackage normally and it had an subsequent event. Now if I schedule this infoapckage in process chain will it raise event after the load finishes.
    Thanks
    Arun Purohit

    Its BW 3.5
    in it when we go into infopackage we get options like..
    Scheduling Options
    Subsequent Processes
    in subsequent processes we can tick on chk box for triggereing event.......
    if I load this infopackage without Process Chain then it will raise event after load finishes....
    my query is?
    will this infopackage raise event if I Schedule it thru Processs Chain after load finishes..
    Edited by: Arun Purohit on Jan 16, 2009 2:24 PM

  • Sound missing after installing windows 8.1 pro.

    hi. i have a problem. after instaling windows 8.1 pro , sound is missing. i in device manager everything is fine. instaled every driver.
    product name:  laptop hp 620.
    a day before this, i had windows 7 and everything worked fine.  tried everything. i dont know what else to do. if i dont find a solution then i go back to windows 7 ((

    Hi:
    The only suggestion I can offer would be to try a W8.1 IDT audio driver...
    http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/swdDetails/?sp4ts.oid=5229457&sp...

  • Infopackage deleted - error in process chain

    Helle experts,
    I have a problem in process chain.
    Today the log advices an error because an Infopackage (that is used in the chain) was deleted yesterday; in fact, in the chain there is an other name for the Infopackage (first question: is this automatically generated?).
    It seems that none deleted it.
    Can you help me, please?
    It's urgent
    I think that the problem can be resolved with the creation of a new Infopackage with the same features of the precedent, but I don't understand the cause of the problem.
    Thanks,
    regards, Vito

    Hi,
    you can check in the log what went wrong for this InfoPackage: transaction SLG1, object RSSM, subobject SDL, external ID = *.
    What kind of name do you have in your chain? Is it a generated name or a name one of you typed for the IPack.
    In a chain some of the packages are generated automatically depending on the process you drag in your chain.
    Creating a new IPack with the same name would work I think, if the package in your chain is not a generated one. If it is a generated IPack, then create a new IPack and drag it in your chain.
    Hope this helps,
    Olivier.

  • Time and Classifieds services missing after installing LabVIEW 8.0

    Hi,
    After installing LabVIEW 8.0 I noticed the Lookout Time and Classifieds services are missing.  At first I thought it was just the Lookout lighthouse in the system tray which had disappeared but when checking in services.msc I can see that the services themselves are no longer there.  The Citadel server is, however.
    I am using Lookout Direct so please let me know if this question is more appropriate on the Automation Direct forums.  I'm trying to change to a NI solution instead but every step is taking me considerable time.
    Thanks,
    Dave

    Try to repair Lookout Direct from Windows Add/Remove Programs. The missing services should be reinstalled after repair.
    Ryan Shi
    National Instruments

  • Gallery blur missing after installing 2014

    missing gallery blur after installing 2014 ps.

    Sorry,
    It was slated to go to the Creative Cloud - Muse area. How it got to Photoshop is beyond me.
    Bob

  • After Even Process Chain

    I have a process chain ‘B’ scheduled in mode ‘After Event: Z_CHAIN’
    How can I see what is ‘Z_CHAIN’?
    I try to see this with SE37 and SE38 but with out any happy result.
    Thank you in advance.

    Hi SSAP,
    z_CHAIN is an event which triggers this process chain.
    This event can be raised through background jobs also.
    You can find oyt the name of the job which triggers this event by going into
    trasaction se11>In database/table name write BTCEVTJOB-click on contents --->
    then write your event name
    Hope this helps.
    Varada

  • Icon missing after installed Adobe

    Hello,
    Does anyone have the mac icons missing issue after installed adobe creative cloud installer?
    My macbook pro icons were missing (didn't show) right after I installed Adobe Creative Cloud Installer (download from Adobe website).
    At first, I thought the issue is my machine, so I went to apple store genius bar and left my mac for a week to let them find out the reason.
    Apple erased my system and reinstalled it, and machine passed all the diagnose test.
    Yesterday, I got my mac at apple retail store and everything was normal (no icon missing).
    Right after I installed Adobe Creative Cloud Installer, the icons were missing. Then, I uninstalled Adobe Creative Cloud Installer, everything was back to normal, including icons were back.
    I have no idea how this happen and why. But according to apple, they told me it should be the software issue and ask adobe for help. Adobe there is no phone call support form Adobe.
    Does anyone have the same issue like this, or does anyone know how to solve the issue?

    Hi Jeff,
    Thank you for your reply. Please see the screenshot.
    This is when I try to create a folder, it happens like this.
    The second one is after I close this folder and reopen it. Please the second image.
    The last image is very funny which I am not able to see anything form applications folder. But, actually, there are a lot of things. As you can see from Dock, there are many things like imessage, Photoshop, chrome etc. They just not shown!
    I can only uninstaller the Adobe Creative Cloud Installer to solve it.
    Do you have any idea how to solve it by any chance? Apple said it was caused by the software. They even replaced my logic board to solve it, but they still couldn't.

  • Due to attribute change run(sid's is missing)...process chain is failed

    Hi All,
    Due to attribute change run (SID's is missing) process chain is failed.kindly suggest me how we can rectify for this issue.
    Thanks
    Ragav

    if master data is loading at same time while the attr/hier change run is occuring,it cause the change run to fail.
    Usually u get error message like..user ALEREMOTE has locked the MD tables..
    Wait for some time and then try attr change run manually by going to rsa1->tools->apply hier/attr change..
    if it still shows locked..try to see in rsmo if a MD load has got stuck..
    else..see in sm12 to find lock is on which tables..
    last resort..delete lock forcefully from sm12..
    first option is wait for some time and give a try again..
    cheers,
    Vishvesh

  • Error in PSA after running process chain

    Hello All,
    I have ran a process chain, which came back with an error.  I have checked the PSA and there is one line which has an error.  How can I resolve it and reload the data into the cube succesfully?  Is there away to delete the data from the PSA and reload it? 
    Thanks,
    Nick.

    Dear Nick,
    I will add the step by step procedure to edit PSA data and update into target (request based).
    Identifying incorrect records.
    System wont show all the incorrect records at the first time itself. You need to search the PSA table manually to find all the incorrect records.
    1. First see RSMO > Details > Expand upate rules / processing tabs and you will find some of the error records.
    2. Then you can go to PSA and filter using the status of records. Filter all the red requests. This may also wont show the entire incorrect records.
    3. Then you can go to PSA and filter using the incorrect records based on the particular field.
    4. If this also doesnt work out go to PSA and sort (not filter) the records based on the particular field with incorrect values and it will show all the records. Note down the record numbers and then edit them one by one.
    If you want to confirm find the PSA table and search manually."
    Also Run the report RS_ERRORLOG_EXAMPLE,By this report you can display all incorrected records of the data & you can also find whether the error occured in PSA or in TRANSFER RULES.
    Steps to resolve this
    1. Force the request to red in RSMO > Status tab.
    2. Delete the request from target.
    3. Come to RSMO > top right you can see PSA maintenace button > click and go to PSA .
    4.Edit the record
    5. Save PSA data.
    6. Got to RSA15 > Search by request name > Right click > update the request from PSA to target.
    Refer how to Modify PSA Data
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/40890eda-1b99-2a10-2d8b-a18b9108fc38
    Hope it helps you,Revert me back if you have any queries
    Assign points if helpful
    Regards
    Bala

  • ZLinux environment variables missing after install

    Suse 9.0 Service pack 2
    Oracle 10g
    During the installation, I had to interactively define a bunch of environment variables. The Oracle installation instructions didn't say to put them in a .profile or any other type of file that may be executed when necessary.
    However, after rebooting, those variables are gone.
    So things like logoning on to the Oracle userid and trying to execute "sqlplus" fails. When I recode these variable, at least it can find the "sqlplus" command.
    Of course, these variables may also be necessary for the db to come up.
    So, I'm backtracking. What did I miss? Where did these variables go? Was there a step that wasn't documented? Was there something I was suppose to "automagically" know?
    So, for those Linux shops, did you have to code a file with these variables?
    I did the "export" command. Sure doesn't look like these variables were saved across boots.
    Any ideas?
    Thanks
    Tom Duerbusch
    THD Consulting

    I'm going to add some things to this.
    In the IBM manual on the installation of Oracle 10g on Suse 9.0, it does show putting the environment variables in the .profile file. (This is under the bash shell.)
    So, last night, I tested .profile. Didn't work. Under the bash shell, the bashrc file would contain items that are executed at logon time. At least by default.
    So, there is something missing, higher up in the food chain. Perhaps something not done during the Linux install that either tells the system to either use the .profile file at logon time (the way the IBM manual says), or automagically keeps the environment variables set across boots, (the way the Oracle Installation manual assumes).
    Anyone recall something like that? Or are most of the people here, been given their Linux images. And your responsibility is only the Oracle DBA side? Perhaps I need to get to a Linux group for this one.
    Thanks
    Tom Duerbusch
    THD Consulting

  • New HP HDD load recovery disks fails to boot after install process on pressing continue

    I have Pavilion d7-4165dx notebook. I live out US, though made purchase from US (BestBuy).
    - HDD failed after renewing trial period of virus software.
    - All diagnostics would not recognize HDD. 
    - HP support indicated still in warranty, but I am out of country.  HP indicated most likely issue was HDD cable.
    - Purchase cables and had someone hand carry out of US.
    - Installed, still same response.
    - Ordered new HDD from HP.  Backordered.  Finally on inquiring was directed to a US 3rd part rep.  He recommended buying directly from outlet, but a higher speed.  Did that and then HP replacement HDD arrives.  Hand carry both out of US.
    - Install faster (slightly smaller) Seagate 500G 7200.  Started recovery with recovery disks (5 total that received from BestBuy, but not OEM looking), but is squawked as new HDD is smaller than original WD 640G 5400.   Put WD into #1 bay and Seagate into #2.
    - Start recovery disk process.  Go through entire recovery from factory process and on last disk, it says to not touch while PC boots on and off, etc.  Then says press Continue to continue.
    - When press continue, simply goes to black screen with "No boot device..."
    - Run other options, same message.
    - Ran diagnostics.  HDD all OK.
    - Called HP support.  He indicates I need to buy the HP recovery disks.  The ones I have (5) are not the right one, that there should only be 3!  They are as I received from BestBuy, but look like they were made there when BestBuy sets up the PC. 
    Any suggestions anyone?
    This question was solved.
    View Solution.

    Sorry, I don't have an answer, but rather a similar issue.  I replaced a 320Gb - 5400 rpm drive that failed with a 750Gb - 7200 rpm drive and even though I have the factory restore disks, it won't recognize the hard drive and I too get the "No Boot device" message.  Unfortunately, the BIOS is not the best and it won't allow me to see if it actually recognizes the new hdd, which I suspect it doesn't.  Either that or I have a bad MB.
    Sytem information - HP G71-340US
    Processor - 2.20 GHz Intel Core2 Duo Processor T6600
    BIOS - InsydeH20 3.5
    Recovery manager *appears* to be installing W7 just fine, but it's a no go when it's time to actually boot to it.  Is this a mb issue or did I just buy the wrong hd?

Maybe you are looking for

  • How to get the cookie from a web service using Axis

    I used the AXIS wizard to consume a WSDL and create a bunch of boiler plate code. It works great in that I can talk to the web service and submit requests. The problem is that I need to retrieve the cookie from the login request and use it when makin

  • Flex with a virtual frame buffer

    I have to run an automated version of my flex app on a headless server so I'm using a virtual frame buffer (Xvfb) running on Solaris in an oc4j container. I can get the following command to 'apparently' launch the app: String cmd = "/bin/sh DISPLAY=:

  • Using orcl:query-database to return a number of Columns

    I have a BPEL process that is pulling data from some Database tables everything is working fine. I now need to perform a lookup on the database to pull in some additional information (3 additional attributes) within the stylesheet, where each attribu

  • Once again, scrolling a view question

    I have been trying to get a view built in Interface Builder to scroll and zoom but I cannot do it. I build a new iPhone project using the "View-Based Application" template. I add my controls to the "MyAppViewController.xib". I set the .xib's class to

  • Answers needed for my questions

    Hello, I need answers for few questions.It helps me a lot.It may be very basics but kindly answer me. )How do you view the value of the parameter that is being used by instance? show parameter..? 2)How do you get the information of hidden parameters