200560 timeout error using DAQmx

I had 2 separate DAQmx tasks working concurrently on the same block diagram.  The two tasks were not triggered, but both were starting at roughly the same time, give or take a few samples.
Next, I wanted to clean up my work and make 2 separate sub VI's from the 2 tasks on my block diagram.  So I coppied on block of code to a new VI and deleted that block of code from the original block diagram.  Now, the task onr the original block diagram gets error 200560 when I try to run it.  Specifically, the error message reads: "200560 occurred at DAQmx Wait Until Done.vi.  Possible reason - Measurements: Wait Until Done did not indicate that the task was done within the specified timeout".  The timeout was set for 10s.
I replaced the block of code for the task that was moved and everything ran fine as before. 
When I single-stepped through the code, I noticed that the second task started before the first task was done.  This led me to suspect some sort of timing issue.  I tried to induce a wait state by inserting a for loop with a 500 ms delay, but it did no good.
Any ideas?

For my application, I'm trying to energize a solenoid coil with a 12V pulse, while at the same time, making an acceleration measurement.  I'm generating the 12V pulse with the 9472 in slot 4 of the compact daq chassis.  I'm making the acceleration measurement with the 9233 in slot 1. 
If you look at the attached VI, write pulse with internal counter_12_11_08.vi, you will see code for the pulse generation at the top of the block diagram and code for the acceleration measurement at the bottem.  If I delete the code for the acceleration measurement, the code for the pulse generation hangs up.
Attachments:
write pulse with internal counter_12_11_08.vi ‏33 KB
Build Pulse Array.vi ‏19 KB

Similar Messages

  • Frame timeout error using Configure Trigger3.vi

    Hi all,
    I'm triggering the frame capture of an .avi with an RTSI connection.  However, I keep getting a frame timeout error when I use the IMAQ Configure Trigger3.vi.  I don't get any timeout errors when I just use the IMAQ Generate Pulse3.vi but I am trying to sync the frame capture to an optical switch.  If I just use IMAQ Generate Pulse3.vi, I get a .avi but the frames are completely out of sync with the switch, but if I use both IMAQ Generate Pulse3.vi  and Configure Trigger3.vi I get nicely separated images but it takes an age and ends up in a timeout error.
    I want to capture e.g. 500 frames, over the course of 2 s - so I've set my frame timeout to be 2000.   At my current acquisition rate (31680 Hz per line (1024 pixels)) 500 frames corresponds to a total of 1.578 s (images are 100 pxls in height).  This is much less than the total scanning time.  Where am I going wrong?
    Thanks in advance for your help.
    Miika
    Attachments:
    screen.png ‏32 KB

    Hey Miika
    What are the hardware you are using. These vi's only work with specific hardware and this may be why they are not functioning correctly. For example the Configure trigger3 vi only works with the following PCIe-1427, PCIe-1429, PCe-1430, PCIe-1433.
    Matthew Trott
    Applications Engineer
    National Instruments UK
    www.ni.com/ask

  • Build error using daqmx vi's crashes LV

    I am trying to build an executable in LV 8.2 (it worked in 8.0) using daqmx create channel.  The build is not successful and sometimes gives no reason and other times tells me to allow debugging.  I allow debugging and the executable tells me I need full development to fix error.  I should be running professional development.  Sometimes I get a LV crash where LV has encountered a problem and needs to close.

    brianpt,
    Thanks for posting to the NI forums.  Do you still have issues if you try to build an application that does not contain any DAQmx code?  What version of DAQmx do you currently have installed?  What is the exact error that you are seeing?  Are you using the LabVIEW Professional Development system?
    Regards,
    Neil S.
    Applications Engineer
    National Instruments

  • Connection Timeout error using Stubs

    Hi
    We are trying to connect to the CRM On Demand through one of our applications using the client Stub mechanism. But everytime we get the below error.
    faultCode: {http://schemas.xmlsoap.org/soap/envelope/}Server.generalException
    faultString: WSWS3713E: Connection to the remote host secure-ausomxbta.crmondemand.com:443 failed.Received the following error: java.net.ConnectException: Connection timed out: no further information.
    faultActor: null
    faultDetail:
    WSWS3713E: Connection to the remote host secure-ausomxbta.crmondemand.com:443 failed.Received the following error: java.net.ConnectException: Connection timed out: no further information
         at com.ibm.ws.webservices.engine.transport.http.HttpOutboundChannelConnection.connect(HttpOutboundChannelConnection.java:936)
         at com.ibm.ws.webservices.engine.transport.http.HttpsOutboundChannelConnection.connect(HttpsOutboundChannelConnection.java:210)
         at com.ibm.ws.webservices.engine.transport.http.HTTPSender.invoke(HTTPSender.java:586)
         at com.ibm.ws.webservices.engine.PivotHandlerWrapper.invoke(PivotHandlerWrapper.java:249)
         at com.ibm.ws.webservices.engine.PivotHandlerWrapper.invoke(PivotHandlerWrapper.java:249)
         at com.ibm.ws.webservices.engine.WebServicesEngine.invoke(WebServicesEngine.java:336)
         at com.ibm.ws.webservices.engine.client.Connection.invokeEngine(Connection.java:937)
         at com.ibm.ws.webservices.engine.client.Connection.invoke(Connection.java:731)
         at com.ibm.ws.webservices.engine.client.Connection.invoke(Connection.java:680)
         at com.ibm.ws.webservices.engine.client.Connection.invoke(Connection.java:502)
         at com.ibm.ws.webservices.engine.client.Stub$Invoke.invoke(Stub.java:1007)
    We are using the URL as https://secure-ausomxbta.crmondemand.com/Services/Integration and the port as 443 in the QName object and setting in the Stub.
    Any help or lead would be of great help. Thanks in advance.
    Regards
    PM

    obvious question - can the machine you are running the code on actually reach the URL on that port? Did you verify with wireshark that you are making a request to that endpoint?
    Thanks

  • Run-Time errors using DAQmx and Borland C++ Builder 5.0

    I've written a simple program on MS Visual C++ 6.0 to test my PCI-6014 board and it works fine.
    I copied the code to Borland C++ builder 5.0 and had some linker problems with the .lib files that where solved with borland's "coff2omf".
    Now I've been getting run-time errors when I use the function DAQmxCreateAIVoltageChan()... The error code is -50251: "The specified software component is not available. The component was not loaded".
    But I'm sure that the code is right, since it works fine on MS Visual C++ 6.0!
    That the part of the code where I'm getting the error:
    iErro = DAQmxCreateTask("", &thTask);
    iErro = DAQmxCreateAIVoltageChan(thTask, "Dev1/ai0", "", DAQmx_Val_Diff, -10.0, 10.0, DAQmx_Val_Volts, NU
    LL);
    Thanks for the help,
    Marcelo

    Hello
    Borland enables certain types of exceptions by default which are initially disable in MSVC. You will need to refer to the documentation for Borland Builder on how to disable floating point exceptions. I believe you can do it by adding the following statement to your initialization code, but you should double check this:
    _control87(MCW_EM, MCW_EM);
    These exceptions get thrown because we are doing some floating point initialization underneath. This is not an indication of a bug or a problem of any sort. Apparently you have to this for alot of libraries to work correctly with Borland (OpenGL etc...)
    Hope this helps
    Bilal Durrani
    NI
    Bilal Durrani
    NI

  • I set up a playlist in itunes and when i tried to sync it to my iphone i get an error message "itunes could not copy "x" to the iphone "x" because a timeout error occured.  Using itunes 10.5.2.11 and Windows Vista 64

    I set up a playlist in itunes and when I try so sync it to my iphone, I get an error message "itunes could not copy "x" to the iphone "x" because a timeout error occurred.  Using itunes 10.5.2.11 and Windows Vista 64.  Any help?  Thanks in advance!

    I have the same question and the only reply I've found on the forum was "change the USB hub", which HASN'T worked. So I am accepting new suggestions. Tks!

  • I lost my connection when I was using internet and when I want to reconnect to airport it give me connection timeout error, I changed my password on router but still doesn't work. How can i fix my problem?

    Hi,
    I lost my airport connection when I was using internet and when I wanted to re-reconnect to airport it gave me connection timeout error, I changed my password on router but still doesn't work. How can i fix my problem?

    Hello there hastibahreini,
    It sounds like you were using your Wi-Fi network from your Airport base station and the connection cut out. You have reset the password on the device but the issue persists. I would try the 3 resets outlined in the following article in order to help resolve the issue. If it persists, is the Wi-Fi connection issue happening on more than one device or computer?
    Resetting an AirPort base station FAQ
    http://support.apple.com/kb/ht3728
    Thank you for using Apple Support Communities.
    Cheers,
    Sterling

  • Timeout errors when using high speed camera.

    Hi all.
    I'm currently trying to capture images using a Mikrotron EoSens MC1363 camera at high frame rates >500fps. The issue arises when the region of interest (ROI) is decreased in the microtron software (of which screenshots are attached). The ROI must be dropped in order to increase the fps. When MAX is opened and configured to match the camera settings, and grab is initiated, the timeout error occurs. I've attached screenshots of the mikrotron software, max settings, the error and PC used. The OS is windows 7 64 bit. We use the camera config file for the mono version of the camera which i've been informed will cross over to satisfy the colour version we use. Any questions feel free to ask. Thanks.
    Attachments:
    errors.docx ‏3016 KB
    997-EoSens 3CL-MC1362-Manual.pdf ‏1209 KB

    Hi Dom.
    As you said the maximum frame rate with the ROI set to 1280 x 1024 is 505fps but according to the general information for the camera series:
    The Mikrotron EoSens camera series features extremely sensitive high-speed
    CMOS sensors available in monochrome or in colour with a resolution of 1280 x
    1024 pixels and capture rates of 110 or 500 frames per second. Depending on
    the model the image data is transferred in 8 or 10 bits via either CameraLink
    (Base, Medium or Full) or Gigabit Ethernet.The region of interest (ROI) can be
    freely selected, and the cameras can achieve even higher capture rates up to
    120,000 fps when the ROI is reduced
    Therefore it was my thought that by reducing the width of the ROI increased frame rates may be reached. Realistically we're looking for as high frame rates as possible so that the camera has capability to pass between projects. Currently the moving object enters and leaves the ROI within a 4 frame window, so frame rates of up to 1000fps would generate more data. Naturally, a point will come where the data cannot be physically written as fast as it is generated (>600MBps). Therefore it would be useful to get a handle onto why the error occurs as well as methods to fix it. Hopefully the problem is being discussed between NI and Mikrotron and we may have some answers in the near future.

  • I am getting a 'MIDI timeout' error message when I open garageband. I am not using any other apps so why is this happening. Restarting does not solve the issue.

    I am getting a 'MIDI timeout' error message when I open garageband. I am not using any other apps so why is this happening. Restarting does not solve the issue.

    I should also add that I am using core audio, no external MIDI device and Garageband v 6.0.5. Thanks

  • Timeout error in Junit using Antscript

    Hi,
    Whenever I am running JUnit Test Cases using AntScript, I am getting following exception:
    junit.framework.AssertionFailed Exception: Timeout Error Occurred.
    I changed timeout attribute in junit task in ant, but getting the same error.
    Is there anyway to bypass this error and show actual error? I am sure it is not timeout error but some runtime uncaught exceptions.

    Hi,
    Whenever I am running JUnit Test Cases using
    AntScript, I am getting following exception:
    junit.framework.AssertionFailed Exception: Timeout
    Error Occurred.
    I changed timeout attribute in junit task in ant, but
    getting the same error.
    Is there anyway to bypass this error and show actual
    error? I am sure it is not timeout error but some
    runtime uncaught exceptions.Are you running TestSuits or TestCases in ant script?
    If you are running TestCases directly using ant script then divide the
    number of Testcases into 2 and place them in 2 Test Suites. Try to run the TestSuites using ant script.
    HTH

  • Getting timeout error while updating a record from c#

    Hi,
    I have around 30k records in a tables. When I update that record inside the Transaction (Enterprise Data Library, c#) , it takes long time and throws timeout error.
    But I am able to update the same record via Toad.
    In the morning I tried same updating the record, it works without any change in the code or script.+
    is it due table lock or db related issue? please adivse, how to resolve if occurs again.
    anand

    Code:
    private static void Save()
    using (DBTransactionManager dbTransactionManager = new DBTransactionManager())
    try
    DataTableDAL.Instance.ExecuteDML("Update Voyage SET BallastBonus = 30000 WHERE ID = 'AE53B610BEA743EC8AFBAED0C8349BF8';");
    //commit database
    dbTransactionManager.Commit();
    catch
    dbTransactionManager.RollBack();
    throw;
    Table
    Column Name     ID     Pk     Null?     Data Type     Default     Histogram     Encryption Alg     Salt
    ID     1     1     N     NVARCHAR2 (32)          None          
    CALCNUMBER     2          N     NUMBER (10)          None          
    CURRENCYID     3          N     NVARCHAR2 (32)          Frequency          
    CALCTYPE     4          N     NUMBER (5)          Frequency          
    ESTIMATEDESCRIPTION     5          Y     NVARCHAR2 (200)          None          
    ESTIMATEGROUPDESCRIPTION     6          Y     NVARCHAR2 (200)          None          
    BALLASTBONUS     7          Y     NUMBER (12,2)          None          
    BALLASTBONUSCOMMPCT     8          Y     NUMBER (6,3)          None          
    ISESTIMATE     9          N     NUMBER (1)          None          
    ADDITIONALSTEAMVALUE     10          Y     NUMBER (8,4)          None          
    ISADDITIONALSTEAMPCT     11          Y     NUMBER (1)          None          
    ADDITIONALPORTVALUE     12          Y     NUMBER (8,4)          None          
    ISADDITIONALPORTPCT     13          Y     NUMBER (1)          None          
    CREATEDBY     14          N     NVARCHAR2 (32)          Frequency          
    CREATEDDATE     15          N     DATE          None          
    UPDATEDBY     16          Y     NVARCHAR2 (32)          None          
    UPDATEDDATE     17          Y     DATE          None          
    LUMPSUMCARGOCOST     18          Y     NUMBER (1)          None          
    BUNKERPRICEMETHOD     19          Y     VARCHAR2 (30 Byte)          None          
    INCCONTCALCRESULT     20          Y     NUMBER (1)          None          
    FINAL_EST     21          Y     NUMBER          None          
    SPOT_VOYAGE     22          Y     NUMBER (1)          None          
    ISRUNCOSTEDIT     23          Y     NUMBER (1)          None          
    Index
    Table doesnt have any index, except primary key index.
    Total Records
    35,000
    Hope this input might sufficient to help me.

  • How manage timeout Session using java SDK?

    Hi everyone !
    I'm working with BO 4.1 and the Java SDK. I'm refreshing and exporting webi reports in my code. But it happens, sometimes, the report takes longer to refresh (when calling "setPrompts") and the session is over (timeout like when you're connected in the Launchpad).
    Is there any specific way for me to test if the call to setPrompts ends without timeout? Because, now, if it ends by a timeout, I do not see anything and I'm exporting a blank document. No error or exception :-/
    Do I have to use de EnterpriseSession?
    Thanks in advance !

    Hi Jerome,
    To understand BO session management, refer to the below document.
    http://scn.sap.com/community/bi-platform/blog/2013/11/27/session-management-bible
    How do you specify that there is a timeout? Do you get timeout errors in web intelligence server logs?
    Check whether enterprise session is still valid.
    What is the approximate time delay you observe for setPrompts when you observe the timeout?
    -Prithvi

  • Open socket timeout error

    Sometime I can write to the local shared variable through data socket. But sometime cannot. Even though, I still can read/write through shared variable monitor.
    The error is in the open socket, said connect to peer timeout. I set timeout to 10s or left blank both not work.
    I am using 8.2.1 on vista. The computer has 2 lan ports.
    I met almost same case long time ago. I solved it by diable NETBIOS and one of the lan port.
    This time, I disabled netbios already. But in vista, seems not able to disable the other lan port.
    Any suggestion?

    hi turbot,
    I had same problem of timeout error.just check if system Firewall is on or off if it is on then make it off and then run the program.i don't know how much this will help you,it helped me.
    GAK
    Gaurav k
    CLD Certified !!!!!
    Do not forget to Mark solution and to give Kudo if problem is solved.

  • Timeout error while running Report

    Hi
    All,
    Windows 2000
    Oracle Report builder 10g
    Oracle developer suite 10g
    when I had OLD computer i was able to run report more than 10 minutes. Now, I got NEW computer and i am getting TIMEOUT error while running report more than 10 minutes.
    Any clue?
    Thanks,
    Vishal

    As Fs says it depends on how you're running the report.
    If you're running via a server then you need to make the change on that server or amend the URL you are using to run the report to add the enginereponsetimeout parameter.
    You can amend this parameter on the server either by using the Application Server Control as I described in my last post or by directly editing the config file. This file will be called <reportservername>.conf and can be found in the oracle_home/reports/conf directory.
    In this file look for the engine tag and see if the engineResponseTimeOut property is set.
    E.g:
    <engine id="rwEng" class="oracle.reports.engine.EngineImpl" initEngine="1" maxEngine="4" minEngine="1" engLife="50" maxIdle="20" callbackTimeOut="90000" engineResponseTimeOut="5">
    </engine>
    This value is in minutes so increase to a time larger than that it takes to run the report.
    If instead you're running the report via Report Builder on your own PC then look for a file called rwbuilder.conf in the same location on your PC and make the same change as described above.
    If this property isn't in the file then the engine isn't supposed to time out at all so the problem may well be something different. But to discount it try setting to a large value like 30.

  • Crystal report server2008 (XI R2): CMC session timeout error

    HI
    Crystal report server2008 (XI R2): CMC session timeout error
                Accessing folders, scheduling reporting or running reports are working fine with Central Management Console (CMC) within the Crystal report server or accessing CMC within VPN machine.  But when CMC is accessed through browser from client desktop i.e through proxy URL, users are not able to access folder or personal folders to view any reports even admin user is not able to access folders. When users try to access folder or personal folders it gives session-timeout errors. Within less than a 1 or 2 minutes it is showing session timeout error. Appreciates any one help on this quickly.
    Regards,
    Patrick Raths

    Please post your query to the [Business Objects Enterprise Administration|BI Platform; forum. This forum is dedicated to development and deployment of .Net applications that connect and interact with BusinessObjects Enterprise, BusinessObjects Edge, or Crystal Reports Server. This includes the development of applications using the BusinessObjects Enterprise, Report Application Server, Report Engine, and Web Services SDKs.
    BTW., if thi is an important issue, I'd recommend creating a phone case.
    Ludek
    Edited by: Ludek Uher on Aug 11, 2010 1:58 PM

Maybe you are looking for

  • Geotagging in new Photos app

    Hi All, I recently upgraded to the new Photos app and realised that there doesn't seem to be a way to add location to a photo's metadata (geotagging). Can any confirm if this is true? Also any work arounds (e.g. other applications etc ) would be help

  • How do I stop Firefox blocking my local newspaper site every time I want to use it?

    Only recently and only on the one site Firefox now demands I press "Allow" to use the site. Cannot see how to stop this happening

  • Chase Bank download difficulties resulting in a blank screen

    Tonight I have had a problem with Chase Bank giving me a blank screen when I tried to download my credit card statement. The file Chase downloaded was always 'statementPdf' (with a total of 6 downloads) and windows always stated that it had no progra

  • Reading committed data

    Hi, I have some questions about read committed isolation level. When does a read committed cursor get and release read locks on the records it is traversing? For example say we have records a,b,c,d and e stored in the BDB database in that order. if t

  • Tiny EPS thumbnails/previews

    Just downloaded a bunch of EPS clipart from clipart.com. Previewing in Bridge CS3 (2.1.1.9). Some preview and thumbnail properly, some show only tiny thumbnails and a similar size preview. Made sure high-quality thumbnails in the Preferences, also pu