4507R Supervisor module question
Hi everyone,
I am getting the following message when I try to configure the gig1/2 interface which is on Sup mod 1 of my 4507 switch.
router(config)#int gig1/2
% WARNING: Interface GigabitEthernet1/2 is usable/operational
% only when this is the only supervisor present.
Show mod is as follows:
Sing85-2Sw1#sh mod
Chassis Type : WS-C4507R
Power consumed by backplane : 40 Watts
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 2 1000BaseX (GBIC) Supervisor(active) WS-X4515
2 2 1000BaseX (GBIC) Supervisor(standby) WS-X4515
I am novice to the way the Sup mods are set up and work. Does the warning mean 'if the active sup mod fails over to the standby I will have a problem'? In that case do I have to configure an interface in mod 2 same as mod 1 so that the setup works during failover? If the warning message means something else please explain.
Thanks in advance.
RB
Hi RB,
The two Gigabit Ethernet interfaces available with redundancy mode are the first Gigabit Ethernet ports on each supervisor. That is, only Gig 1/1 and Gig 2/1 are available. The other two ports, Gig 1/2 and Gig 2/2, are not available.
Unlike Cat6500 platform where all ports are active, the Cat4507R has redundancy on ports themselves,
meaning if you have two Supervisor IVs, it will only make ports 1/1 and 2/1 active and rest will be the failover ports in case active ones need to failover.
So, for an example, you have 1/1 and 2/1 active. If 1/1 would fail, then you will have 1/2 and 2/1
active. Below is the documentation on this.
4507 : Supervisor Engine Redundancy Guidelines and Restrictions:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat4000/12_1_13/config/rpr.htm#1097897
HTH,
Bobby
Similar Messages
-
6509 - 720 Supervisor Module Failure after Password Recovery
Hi,
I attempted to perform a password recovery on a 6509 with dual WS-SUP720-3B modules running 12.2(33)SXI2A.
After changing the configuration register to 0x2142 and booting, I am getting a major error on the supervisor modules. I've changed the configuration register back to 0x2102 and am still getting the same error on both supervisor modules. I've also tried it with one module removed and one module installed.
I have about 30 seconds in where I can run commands before I get booted to rommon.
Any thoughts?
See below for the console output:
System Bootstrap, Version 8.5(3)
Copyright (c) 1994-2008 by cisco Systems, Inc.
Cat6k-Sup720/SP processor with 524288 Kbytes of main memory
Autoboot executing command: "boot bootdisk:"
Initializing ATA monitor library...
string is bootdisk:s72033-ipservicesk9-mz.122-33.SXI2a.bin
Loading image, please wait ...
Initializing ATA monitor library...
Self extracting the image... [OK]
Self decompressing the image : ################################################################################################################################################################################################### [OK]
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, s72033_sp Software (s72033_sp-IPSERVICESK9-M), Version 12.2(33)SXI2a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Compiled Wed 02-Sep-09 01:25 by prod_rel_team
Image text-base: 0x40101328, data-base: 0x4224F120
*Apr 19 05:03:02.747: %SYS-SP-3-LOGGER_FLUSHING: System pausing to ensure console debugging output.
*Apr 19 05:03:01.515: %PFREDUN-6-ACTIVE: Initializing as ACTIVE processor for this switch
Firmware compiled 19-May-09 12:08 by apyu Build [25600]
*Apr 19 05:03:02.747: %OIR-SP-6-CONSOLE: Changing console ownership to route processor
System Bootstrap, Version 12.2(17r)SX5, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 2006 by cisco Systems, Inc.
Cat6k-Sup720/RP platform with 524288 Kbytes of main memory
Download Start
Download Completed! Booting the image.
Self decompressing the image : ############################################################################################################################################################################################################################################################################################################################ [OK]
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, s72033_rp Software (s72033_rp-IPSERVICESK9-M), Version 12.2(33)SXI2a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Compiled Wed 02-Sep-09 01:00 by prod_rel_team
Image text-base: 0x40101328, data-base: 0x43A51E70
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
[email protected].
cisco WS-C6509-E (R7000) processor (revision 1.5) with 458720K/65536K bytes of memory.
Processor board ID SMC133600GT
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
Last reset from s/w reset
1 Virtual Ethernet interface
194 Gigabit Ethernet interfaces
1917K bytes of non-volatile configuration memory.
8192K bytes of packet buffer memory.
65536K bytes of Flash internal SIMM (Sector size 512K).
--- System Configuration Dialog ---
Would you like to enter the initial configuration dialog? [yes/no]: no
Press RETURN to get started!
*Apr 19 04:55:51.335: RP: Currently running ROMMON from S (Gold) region
*Apr 19 04:55:52.107: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan. The Bridge IDs of all active STP instances have been updated, which might change the spanning tree topology
*Apr 19 04:56:00.531: %SYS-5-RESTART: System restarted --
Cisco IOS Software, s72033_rp Software (s72033_rp-IPSERVICESK9-M), Version 12.2(33)SXI2a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c)
Router> 1986-2009 by Cisco Systems, Inc.
Compiled Wed 02-Sep-09 01:00 by prod_rel_team
*Apr 19 05:03:03.111: %SYS-SP-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output.
*Apr 19 04:55:46.739: %SPANTREE-SP-5-EXTENDED_SYSID: Extended SysId enabled for type vlan. The Bridge IDs of all active STP instances have been updated, which might change the spanning tree topology
*Apr 19 04:55:46.747: SP: SP: Currently running ROMMON from S (Gold) region
*Apr 19 04:55:47.483: %SCHED-SP-7-WAen
Router#TCH: Attempt to set uninitialized watched boolean (address 0). -Process= "<interrupt level>", ipl= 1, pid= 3
-Traceback= 408E0820 40D74FEC 40D4B31C 40D4A1A8 40D46448 40F604B8 4173CCDC
*Apr 19 04:55:59.607: %SYS-SP-5-RESTART: System restarted --
Cisco IOS Software, s72033_sp Software (s72033_sp-IPSERVICESK9-M), Version 12.2(33)SXI2a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Compiled Wed 02-Sep-09 01:25 by prod_rel_team
Router#
Router#Apr 19 04:56:00.591: %OIR-SP-6-INSPS: Power supply inserted in slot 1
*Apr 19 04:56:00.695: %C6KPWR-SP-4-PSOK: power supply 1 turned on.
*Apr 19 04:56:00.943: %OIR-SP-6-INSPS: Power supply inserted in slot 2
Router#
Router#
Router#
*Apr 19 04:56:08.099: %FABRIC-SP-5-CLEAR_BLOCK: Clear block option is off for the fabric in slot 5.
*Apr 19 04:56:08.195: %FABRIC-SP-5-FABRIC_MODULE_ACTIVE: The Switch Fabric Module in slot 5 became active.
Router#
Router#
Router#
*Apr 19 04:56:09.567: %DIAG-SP-6-RUN_MINIMUM: Module 5: Running Minimal Diagnostics...
Router#
Router#
Router#
Router#show diagnostic result
% Incomplete command.
Router#show diagnostic result ?
module Module Keyword
Router#show diagnostic result ,modu modjle ule 5
Current bootup diagnostic level: minimal
Module 5: Supervisor Engine 720 (Active) SerialNo : SAL1338YTZ0
Overall Diagnostic Result for Module 5 : UNTESTED
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestScratchRegister -------------> U
2) TestSPRPInbandPing --------------> U
3) TestTransceiverIntegrity:
Port 1 2
U U
4) TestActiveToStandbyLoopback:
Port 1 2
--More-- U U
5) TestLoopback:
Port 1 2
6) TestNewIndexLearn ---------------> .
7) TestDontConditionalLearn --------> .
8) TestBadBpduTrap -----------------> .
9) TestMatchCapture ----------------> .
10) TestProtocolMatchChannel --------> .
11) TestFibDevices ------------------> F
12) TestIPv4FibShortcut -------------> F
13) TestL3Capture2 ------------------> F
14) TestIPv6FibShortcut -------------> F
15) TestMPLSFibShortcut -------------> F
16) TestNATFibShortcut --------------> F
17) TestAclPermit -------------------> F
18) TestAclDeny ---------------------> U
--More-- 19) TestQoSTcam ---------------------> U
20) TestL3VlanMet -------------------> U
21) TestIngressSpan -----------------> U
22) TestEgressSpan ------------------> U
23) TestNetflowInlineRewrite:
Port 1 2
U U
24) TestFabricSnakeForward ----------> U
25) TestFabricSnakeBackward ---------> U
26) TestTrafficStress ---------------> U
27) TestFibTcamSSRAM ----------------> U
28) TestAsicMemory ------------------> U
29) TestAclQosTcam ------------------> U
30) TestNetflowTcam -----------------> U
31) ScheduleSwitchover --------------> U
32) TestFirmwareDiagStatus ----------> U
33) TestAsicSync --------------------> U
34) TestUnusedPortLoopback:
--More--
Router#[Ashow diagnostic result module 5
Current bootup diagnostic level: minimal
Module 5: Supervisor Engine 720 (Active) SerialNo : SAL1338YTZ0
Overall Diagnostic Result for Module 5 : UNTESTED
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestScratchRegister -------------> U
2) TestSPRPInbandPing --------------> U
3) TestTransceiverIntegrity:
Port 1 2
U U
4) TestActiveToStandbyLoopback:
Port 1 2
--More--
Router#
*Apr 19 04:56:29.637: %DIAG-SP-3-MAJOR: M
%Software-forced reload
04:56:30 UTC Sun Apr 19 2015: Breakpoint exception, CPU signal 23, PC = 0x42735338
Possible software fault. Upon reccurence, please collect
crashinfo, "show tech" and contact Cisco Technical Support.
-Traceback= 42735338 42732E8C 423A6220 423A624C 421C1388 4223F614 4223F670 40962164 40963034 40962F54 40963D28 423259D0 42319604 42319820 42727FEC
$0 : 00000000, AT : 43FE0000, v0 : 45870000, v1 : 00000200
a0 : 46DC99C0, a1 : 44E05758, a2 : 00000000, a3 : 00000040
t0 : 00000010, t1 : 3400F101, t2 : 3400F100, t3 : FFFF00FF
t4 : 42728608, t5 : 00002F04, t6 : 80000000, t7 : 00000000
s0 : 00000000, s1 : 43EE0000, s2 : 50449158, s3 : 0000001F
s4 : 50449158, s5 : 470B3AB4, s6 : 00000000, s7 : 08A5DFC8
t8 : 08028FEC, t9 : 00000000, k0 : 00000000, k1 : 00000000
gp : 43FDDE8C, sp : 5000DBB0, s8 : 00000000, ra : 42732E8C
EPC : 42735338, ErrorEPC : 870FDDF0, SREG : 3400F103
MDLO : 00000000, MDHI : 00000000, BadVaddr : 00000000
DATA_START : 0x43A51E70
Cause 00000824 (Code 0x9): Breakpoint exception
Writing crashinfo to bootflash:crashinfo_20150419-045630
=== Flushing messages (04:56:30 UTC Sun Apr 19 2015) ===
Buffered messages:
*Apr 19 04:55:51.335: RP: Currently running ROMMON from S (Gold) region
*Apr 19 04:55:52.107: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan. The Bridge IDs of all active STP instances have been updated, which might change the spanning tree topology
*Apr 19 04:56:00.531: %SYS-5-RESTART: System restarted --
Cisco IOS Software, s72033_rp Software (s72033_rp-IPSERVICESK9-M), Version 12.2(33)SXI2a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Compiled Wed 02-Sep-09 01:00 by prod_rel_team
*Apr 19 05:03:03.111: %SYS-SP-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output.
*Apr 19 04:55:46.739: %SPANTREE-SP-5-EXTENDED_SYSID: Extended SysId enabled for type vlan. The Bridge IDs of all active STP instances have been updated, which might change the spanning tree topology
*Apr 19 04:55:46.747: SP: SP: Currently running ROMMON from S (Gold) region
*Apr 19 04:55:47.483: %SCHED-SP-7-WATCH: Attempt to set uninitialized watched boolean (address 0). -Process= "<interrupt level>", ipl= 1, pid= 3
-Traceback= 408E0820 40D74FEC 40D4B31C 40D4A1A8 40D46448 40F604B8 4173CCDC
*Apr 19 04:55:59.607: %SYS-SP-5-RESTART: System restarted --
Cisco IOS Software, s72033_sp Software (s72033_sp-IPSERVICESK9-M), Version 12.2(33)SXI2a, RELEASE SOFTWARE (fc2)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2009 by Cisco Systems, Inc.
Compiled Wed 02-Sep-09 01:25 by prod_rel_team
*Apr 19 04:56:00.591: %OIR-SP-6-INSPS: Power supply inserted in slot 1
*Apr 19 04:56:00.695: %C6KPWR-SP-4-PSOK: power supply 1 turned on.
*Apr 19 04:56:00.943: %OIR-SP-6-INSPS: Power supply inserted in slot 2
*Apr 19 04:56:08.099: %FABRIC-SP-5-CLEAR_BLOCK: Clear block option is off for the fabric in slot 5.
*Apr 19 04:56:08.195: %FABRIC-SP-5-FABRIC_MODULE_ACTIVE: The Switch Fabric Module in slot 5 became active.
*Apr 19 04:56:09.567: %DIAG-SP-6-RUN_MINIMUM: Module 5: Running Minimal Diagnostics...
*Apr 19 04:56:29.637: %DIAG-SP-3-MAJOR: Module 5: Online Diagnostics detected a Major Error. Please use 'show diagnostic result <target>' to see test results.
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestFibDevices failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestIPv4FibShortcut failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestL3Capture2 failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestIPv6FibShortcut failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestMPLSFibShortcut failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestNATFibShortcut failed
Queued messages:
*Apr 19 04:56:33.583: %SYS-3-LOGGER_FLUSHING: System pausing to ensure console debugging output.
IPv6FibShortcut failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestMPLSFibShortcut failed
*Apr 19 04:56:29.641: %CONST_DIAG-SP-3-BOOTUP_TEST_FAIL: Module 5: TestNATFibShortcut failed
*Apr 19 04:56:29.971: %HA_EM-6-LOG: Mandatory.go_bootup.tcl: GOLD EEM TCL policy for boot up diagnostic
*Apr 19 04:56:30.575: %CPU_MONITOR-3-PEER_EXCEPTION: CPU_MONITOR peer has failed due to exception , reset by [5/0]
*** System received a Software forced crash ***
signal= 0x17, code= 0x24, context= 0x45876f54
PC = 0x42728664, SP = 0x43ed9cd8, RA = 0x413ad2f4
Cause Reg = 0x00003820, Status Reg = 0x34008002
rommon 1 >What kind of line card was being inserted in slot 6? Have you tried other slots? The crash file in the RP says it was reset by SP, so the important crashinfo file would be in the sup-bootflash: Try an see if you find any "dir sup-bootflash:"
Aug 5 17:46:11: %C6K_PLATFORM-2-PEER_RESET: RP is being reset by the SP
%Software-forced reload
To answer your question:
A Is there any different procedure to install line modules in supervisor slots?
>>No there are no special configuration you need to do when inserting a line card in slots that normally would be for supervisor.
B Switch is having previously removed linecard (i.e, fastethernet module)in running configuration. Will it create any system crash?
>>No, it will not cause the switch to crash, when you see the configuration of a line card even after it was removed is quite normal, it's cold module provisionsing, you would not want to keep putting in a configuration for any line card after just resetaing them do you? -
Nexus 7000's Supervisor Module cannot boot up
Hi all,
I have one of redundant supervisor module in Nexus 7010 that cannot boot up. I tried to do recovery from loader but it cannot boot the kickstart image and reboot again. The log is :
loader> set ip 192.168.253.10 255.255.255.0
Correct - ip addr is 192.168.253.10, mask is 255.255.255.0
Found Intel 82546GB [2:9.0] at 0xe040, ROM address 0xf980
Probing...[Intel 82546GB]
Management interface
Link UP in 1000/full mode
Ethernet addr: C0:62:6B:AD:35:80
Address: 192.168.253.10
Netmask: 255.255.255.0
Server: 0.0.0.0
Gateway: 0.0.0.0
loader> boot tftp://192.168.253.43/n7000-s1-kickstart.5.1.5.bin
Address: 192.168.253.10
Netmask: 255.255.255.0
Server: 192.168.253.43
Gateway: 0.0.0.0
Filesystem type is tftp, using whole disk
Booting: /n7000-s1-kickstart.5.1.5.bin console=ttyS0,9600n8nn quiet loader_ver=
"3.22.0"....
....................Image verification OK
INIT: owner_pc=c03a7956 held lock for 5010 msec
NX7 SUP Ver 3.22.0
Serial Port Parameters from CMOS
PMCON_1: 0x200
PMCON_2: 0x0
PMCON_3: 0x3a
PM1_STS: 0x101
Performing Memory Detection and Testing
Total mem found : 4096 MB
Performing memory test... Passed.
NumCpus = 2.
Status 61: PCI DEVICES Enumeration Started
Status 62: PCI DEVICES Enumeration Ended
Status 9F: Dispatching Drivers
Status 9E: IOFPGA Found
Status 9A: Booting From Primary ROM
Status 98: Found Cisco IDE
Status 98: Found Cisco IDE
Status 98: Found Cisco IDE
Status 90: Loading Boot Loader
Reset Reason Registers: 0x0 0x8
GNU GRUB version 0.97
Loader Version 3.22.0
Netbooting via EOBC ...
Found Intel 82571EB [4:0.1] at 0xc000, ROM address 0x0000
Probing...[Intel 82571EB]
Sup-to-sup interface
Ethernet addr: 00:00:00:00:05:00
Address: 127.1.2.5
Netmask: 255.255.0.0
Server: 127.1.1.6
Gateway: 0.0.0.0
Address: 127.1.2.5
Netmask: 255.255.0.0
Server: 127.1.1.6
Gateway: 0.0.0.0
Filesystem type is tftp, using whole disk
Booting: /img-sync/curr-ks.img console=ttyS0,9600n8nn isanimg=tftp://127.1.1.6/
img-sync/curr-isan.img quiet loader_ver="3.22.0"....
....................Image verification OK
INIT: version 2
Does anybody have an idea?
Thanks.That makes sense.
1. Restore the default VDC config.
2. Create your second VDC.
3. Restore the second VDC config.
Don't forget to have a backup of any license files that you may have purchased, for example MPLS. -
Using SNMP to monitor Nexus 7000 Series Supervisor Module
Hello,
I got a Nexus 7000 supervisor module recently, I met a SNMP problem for this module
I would like to know which specific OIDs to use to monitor the following using SNMP on a Nexus 7000 supervisor module:
- Port status
- CPU total utilization
- Power Supply status
- Chassis Fan status
etc.
The Nexus is quite different from other Cisco devices - any help will be appreciated!hope help, and
port status OID is ifOperStatus
CPU total utilization OID is 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1
[root@NET-MONITOR-1 ~]#
[root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 ifDescr.83886080
.1.3.6.1.2.1.2.2.1.2.83886080 = STRING: mgmt0
[root@NET-MONITOR-1 ~]#
[root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 ifOperStatus.83886080
.1.3.6.1.2.1.2.2.1.8.83886080 = INTEGER: up(1)
[root@NET-MONITOR-1 ~]#
[root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1
.1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 = Gauge32: 21
[root@NET-MONITOR-1 ~]# -
Order the FAQ module questions
I am trying to order the FAQ module questions in Business Catalyst.
It puts them in alphabetical order by default so I numbered them. But once it gets to 10 it obviously goes out of order.
And the client does not want to put a letter in front. ie A, B, C
Any ideas on how to acheive this?
Thanks in advance.Try leaving numerical gaps in your weighting scheme so you have future flexibility.
For example, I like to use the weightings of 1000, 900, 800, 700 and so on.
Then I have a LOT of wiggle room to add new information and sort my information the way I like.
Tricia -
Training and Event module questions.
Hi .
I have some questions regarding Training and Event Management module.
1. IS there a way to configure a custom attendee type for this module ?
2. If no is there a way to rename a existing attendee type. I have a requirement to create a group of attendees type of External Person. I know i can use Company attendee type for grouping external person. But i need to change this Company to Group for displaying purposes. I know i can change the Company via T7778O table but won't it lead to bad consequences ?
3. Is there a way to hide tabstrips on PVOO screen ? i have a requirement to keep only Company tabstrip others are not relevant for my scenario.
That's all for now.
Thanks in advance.
Edited by: kernel.panic on Dec 22, 2010 8:47 AMHi,
thanks this one is ok, the one which I can not find is the info message for when the maximum capacity of the attendee list is reached:
'Optimum capacity reached, only essential or wait list bookings possible' This one I want to change into a warning message.
br,
Ovidiu
And I have a new question as well
In the Attendee List layout is it possible to add columns which are not in the column set from customizing e.g. Personnel subarea,
Employee subgroup, Employee group etc?
Thanks
br,
Ovidiu
Edited by: Ovidiu Moldovan on Apr 20, 2010 3:51 PM -
Hi all,
My scenario is File->XI->R3
Can I validate file information in a Sender Adapter Custom Module and if the validation fails then cancel the input so Integration Engine never gets the corresponding message? My question is how to cancel the procesing of the message in the adapter module?
Thanks in advance,
Diego.Chandu,
my problem is that I want to validate data of an input file, so if the file doesn't contain certain fields, then it doesn't go to the XI Engine. (It's discarded before that.)
So i thought to build a module for the sender adapter that do this validation, but I don't know how to discard the message at modules chain.
I hope you could understand my english.
Regards,
Diego. -
This is more of an equipment question, but I figure that thisis as good a
place as any to ask.
I've got about six 5B32 modules, and I need three. The problem is that
four of the resistors that go with them are bad. I had as bad board,
which I think might have screwed up the resistors. The resistors that
Ihave that are good are reading about 20 Ohms of resistance, and the bad
ones are 6 Ohms, 80 Ohms, 1.5 megaOhms, and 2.2 megaOhms.
I have tried to buy some resistors from National Instruments and Analog
Devices, but they don't know what they are (the part number doesn't come
up at all). I hate to keep buying entire 5B32 modules when I only need
the resistor. So, can I just go buy a 20 Ohm resistor at Radio Shack, and
plug it i
n, or is this thing that comes with it something special?
Thanks in advance,
Harry
"Little Joe for the Big Heisman, '99"Absolutely - go down to Radio Shack and purchase some - The max current
sould be 20 ma (since the 5B32 is a 4 - 20 ma current input module) so P =
I^2 R , P = (.02)^2 * 20 = .008 Watts therefore a 1/4 or 1/2 watt resistor
should be more than adequate.
A 1/2 watt resistor has leads that would probably plug into the 5B01
backplane nicely.
Good Luck
Harry King wrote in message <7q65an$[email protected]>...
>This is more of an equipment question, but I figure that thisis as good a
>place as any to ask.
>
>I've got about six 5B32 modules, and I need three. The problem is that
So, can I just go buy a 20 Ohm resistor at Radio Shack, and
>plug it in, or is this thing that comes with it something special?
>
>Thanks in advance,
>Harry
>
>--
>"Little Joe for the Big Heis
man, '99" -
I have a link bar component that is linked to a ViewStack
component, which has four stacks. I want to use modules in the last
three stacks and my question is: Will the modules load when the
user clicks on that particular stack, or will all of them be loaded
even if the currentView property is set to 0?I think that that has to do with the "creation policy" and
can be set either way. -
Hi all,
I am newbe in STREAM module development and this question might be a concept error. If so, please could you give me some clues?
I would like to use the "libc" funcion "getpwuid()" in a kernel STREAM module.
I have Solaris 7 64-bit kernel.
�Can I do it? I have read that for 64-bit kernels, only dynamic libraries are available. Therefore in order ot use libc functions I would have to link dynamically the module relocatable object with the libc library in sparcv9. I have tried to link the kernel STREAM module with libc.so.1 (in /usr/lib/sparcv9) with no success so far. Everytime I trie to load the module it complains with the message: unknown symbol "getpwuid".
If it is not possible, why? . Is it not possible to use libc functions such us: memcpy() etc..from the kernel context?
Looking forward to hearing from you.
Best RegardsYou cannot use user space libraries from within a kernel module. What exactly are you trying to
do? What do you need password information for
down in the kernel?
Maybe ddi_get_cred() will help?
Some functions like memcopy have kernel space equivalents (bcopy)....
dan -
Hi,
I am currently working on designing phase for an Array Module. We are planning to track the Array information and store it's content to database. Currently I am finalizing the data model and I have following question.
--We need to track the Geneology of the Sample through out the whole system (Especially the results of Transfers). Is it better to have all that relationship in one flat table with columns for location (like PlateWell, GelLane ..) and columns for Content (Column like . LocationType LocationId ContentType ContentId) or is it better to store all the content of location as a ArrayType? Or is there any other option available in the Market?
In the first case database rows for that table will increate very very fast plus to find out the geneology of the location in Array , I have to use Connect By Prior which will take good amount of time(Is there any other option available?). I dont have much idea about second option but I think retrieval individual content is going to be a problem.
Any help is really appreciated.
Thanks in Advance
RajMade a complete example:
String searchKey = "Juice";
TreeMap tm = new TreeMap();
tm.put("soda", "coke");
tm.put("Juice", "orange");
tm.put("SODA", "7-up");
Set set = tm.entrySet();
Iterator iterator = set.iterator();
while( iterator.hasNext() ) {
Map.Entry entry = (Map.Entry)iterator.next();
if(entry.getKey().equals(searchKey)){
System.out.println("searchKey '"+searchKey+"' value is: "+entry.getValue());
What do you think? Anything obvious that can be improved? -
NM-16AM module question in my cisco 3660
hi,
I have 3 of these modules.
with 1 module, when I configure a line and I connect to the line I get only a black screen.
when I do the exact same thing with another module, (configure a line on the 2nd module) it works fine.
my question is, how can I know if a module is broken or not functional. can this happen?
any advice on how to find out if a module is broken or if I single modem in the module is dead.
thank you.
also when I use debug modem and I call a modem that works fine I get this
11w6d: Modem 5/14 Mcom: in modem state 'Dialing/Answering'
11w6d: Modem 5/14 Mcom: in modem state 'Incoming ring'
11w6d: Modem 5/14 Mcom: in modem state 'Waiting for Carrier'
but when I don't get this I know in advance that it's not going to work and that I'll get just a black screen.
any advice please?
thank you.To identify a functional module , we need to look at the front panel LED of 3660 router. If READY 0, 1, 2, 3 is blinking green it indicates,it indicates the functional module is installed in the slot.If this LED is OFF, it indicates the slot is empty or the module is not functional. For more info on 3660 MAR router, refer the following Link.
http://www.cisco.com/en/US/products/hw/routers/ps274/prod_module_configuration_guide09186a00800d9e97.html -
Hi all
i have some question about the robotic module.
i already have a DH table for my robto arm.
Now i am trying to input this DH parameters into Labview.
I saw the example of inverse kinematis for puma 560.
Also,I find that the "create PUMA 560 Modified.Vi" can let user to input their only DH parameters.
But
What is the Twist in Labview? angle about previous Z, from old X to new X.
What is the Length in Labview? is it represent thelength of the common normal (r).
What is the Offset in Labview?offset along previousZ to the common normal.
What is the Joint Corrdinate Offseti? in Labview?offset along previousZ to the common normal.
When i modify the DH paramters into "set kinematic parameter.vi",there show a error about -310040.
Anyone can indicate which part i get worg?
Thank you so much
Tim
Attachments:
Inverse Kinematics for Puma 560 org Test.vi 34 KB
Test_PUM_560_tim.vi 32 KB
myrobotarm.jpg 98 KBHi Tim,
Thanks for your question. Are you attempting to modify the "create PUMA 560 Modified.vi" that you mentioned using your DH parameters, or are you modifying the "Test_PUM_560_tim.vi" example VI that you attached? The "Inverse Kinematics for PUMA 560 org Test.vi calls the "Test_PUM_560_tim.vi" so if you are using this example as a model, you would have to input your parameters (Length, Twist, Offset which you mentioned) into that VI.
The particular error you are getting (-310040) corresponds to the following error message: "LabVIEW cannot converge to a solution in the number of steps you specified. Make sure that the serial arm can achieve the transform you desire." This could be due to the fact that the current constraints are over defined.
Here is a link to the Robotic Help Manual:
http://zone.ni.com/reference/en-XX/help/372983D-01/
If you would like to give me some more information about your application, I would be happy to help further. Which version of LabVIEW are you using, and which version of the Robotics Module are you working with?
Good luck!
R. Brill
Applications Engineer
National Instruments -
Very basic modules questions (ath_pci, etc)
Hello! (I'm sorry, I posted this one in another forum first, thinking I was posting it in this one :oops: )
I have a very simple question:
Where can I find modules (e.g., ah_pci for my Atheros mini PCI wireless card), and where and how do I install them?
For example, when I do:
modprobe ath_pci, I get a message saying something like:
can't find ath_pci module;
although I've seen a directory with this name on my system (IIRC, under /sys/drivers???).
Other example:
I have a 855GM Intelchipset. How do I find the module for it and how do I install it?
Thanks a lot.Thanks for the reply, and for deleting the other thread.
I looked for /lin/modules, and I don't have a /lin directory... Is it normal?
Or maybe you meant /bin/modules...? Anyway, I looked for this too and there is no /modules directory under /bin.
I found some modules under /sys/module. There is one named ide_cd that I put in the MODULES array of rc.conf (just for a test, I don't know why it is for...), but I get a message at bootup:
[/code]FATAL: module ide_cd not found[code]
Is this normal too? Or it has to be compiled with the kernel to work. And BTW, if I compile the kernel (I don't think I'm at this point in Linux yet!), do I loose my installation or if everything stays in place in my system?
Thanks a lot![/code] -
Strange problem in AFW custom module (question for gurus)
Hi there SDN'ers,
I have I very strange problem with an additional Adapter Module I developed.
My scenario is: IDOC -> JDBC (Oracle)
Well, to make a long story short, say that before the JDBC Receiver cc can write my data to the db, I have to do (inside the channel) kinda java mapping in order to produce an XML document that is acceptable for it. So in my module I manipulate the payload via DOM. No problem here.
The strange story is: at first attempt, the Adapter fails (see error below), while after 5 minutes, when automatically trying again, it succeeds.
Just because I put some stuff in the message audit log, what I can tell you is this weird thing:
1. at first, no XML document exists in the payload, but in place of it there's this string:
org.apache.crimson.tree.XmlDocument@745501c6
which seems to be a toString() of something I don't (or don't know to) use directly
2. at the second attempt, even in the audit log I can actually see the weel-formed XML document ready for the JDBC adapter, and in fact data are written to the db.
?? WHAT COULD THIS BE CAUSED BY ??
Say also that the the other way around (JDBC->IDOC) with another very similar module works perfectly.
Thanks.
Alex
<b>Delivery of the message to the application using connection AFW failed, due to: ERROR occured parsing request:com.sap.engine.lib.xml.parser.NestedSAXParserException: Fatal Error: com.sap.engine.lib.xml.parser.ParserException: XMLParser: No data allowed here: (hex) 6f, 72, 67(:main:, row:1, col:3)(:main:, row=1, col=3) -> com.sap.engine.lib.xml.parser.ParserException: XMLParser: No data allowed here: (hex) 6f, 72, 67(:main:, row:1, col:3).</b>
P.S. -> 6f, 72, 67 is "org", that is the first three letter of the weird payload I get at first attempt.Ok guys, I got that workin'.
I don't know why - and don't think I'll have the time to investigate further - but it seems the implementation of DOM Document used by XI is different the first time AFW executes my module, so here my workaround.
if (docOut instanceof org.apache.crimson.tree.XmlDocument) {
org.apache.crimson.tree.XmlDocument tmpDocOut = (org.apache.crimson.tree.XmlDocument)docOut;
tmpDocOut.write(out);
} else {
out.write(docOut.toString().getBytes());
Regards,
Alex
Maybe you are looking for
-
Gmail smtp (outgoing) mail not working with apple mail 5
Hi, I have a numbe of gmail accounts, I can receive mail through the new apple mail 5 client but can't send any at all. I've tried everything gmail help suggests but to no avail... Cheers, Alex
-
Digital Noise - DVI Port 1 only
Last night one of the two Viewsonic VX910 monitors connected to my G5 went dark and would flicker on for less than a second (showing the correct screen) then blink out. Called Viewsonic and it's under warranty It was in port 1 of the built in AGP car
-
I am setting up a computer image for my school and next year we want all the macs to switch over to use a secured wireless network instead of the current unsecured one. Unfortunately if you switch the airport to use another wifi signal and back to us
-
Business Workflow, CATS and Universal Worklist
Hi, I've been searching the forums for answers, but haven't found any.. So here's a question. We are going to implement worklow for approving time. We are using MSS/ESS, and the approval will occur in the universal worklist. As far as we can see, we
-
Dynamic types with CL_ABAP_TYPEDESCR
Hi, I have a problem. I want to read out the output_length of dynamic types to evaluate inputs. I do something like the code below. DATA type_ref TYPE REF TO cl_abap_typedescr. DATA elem_descr TYPE REF TO cl_abap_elemdescr. DATA struc_descr TYPE