ABAP HR enhancement for Short profile in PB20 or PB30

Hello gurus,
I am trying to display shortprofile in trnsaction PB20 and PB30.
Here values are coming but I want to know from where and how this values are coming as I need to display some extra text for this.
Here requirement is there is some short profile field on portal application and I need to display this text in R3 when user clicks on that short profile button on application bar of PB20 or PB30 screen.
I need some enhancement like I can read table and display this extra text with this coming values as well.
Can any anybody please explain how can I make this possible?
I am going to post same thread for ABAP HR also.
Thanks in Advance.

I have resolved it my self,
I have enhanced all standared infotypes as per my requirement and this infotype is getting called in this short profile code.
There is no other option.

Similar Messages

  • MSS-short profile N/A

    Dear Experts,
    I am facing an issue in MSS under the workset "Organization" for the services "organization" and "position" profile
    when i am selecting the "organization profile" and the data for short profile is displayed as N/A.
    I did the configuraion in org chart for mss in ECC.
    Please find the attached screen shot of the issue and help me to resolve it.
    Thanks in advance.

    Just to let you know, sequence numbers should be maintained correctly Following is the path in the IMG: Personnel Management->manager self-service (Web Dynpro ABAP )->Profile Applications->Configure Short profile-> create configuration with field groups. In this Customizing activity, you specify how user interfaces that comprise groups of fields are displayed in Manager Self-Service (WDA). Under this entry you can see the fields being assigned. Here the fields has to be maintained in sequencial order. (i.e) number it correctly. However in your case there are two entries maintained with the same number. Please refer to the attachment for the details.  In general, the system assumes the sequential number are maintained. The system builds the UI dynamically and the label names are named against the squence numbers . You can debug from here Program      RP_MSS_LAUNCH_PROFILE V_T77TMCDRCNFFLD_GRP

  • PB30 Short Profile enhancement problem

    Hi Experts,
    If you go to the PB30 Tcode there is a tab for applicant short profile..named just 'short profile'.When you hit that, it shows all the details of the applicant which you have entered from T code PB10 which is Initial entry of applicant master data.
    On this short profile screen I need to enhance it with an additional field PERNR which is the personel number which is currently non existing.The output of this screen seems to be coming from a Script which I am not able to identify yet.When I dig into the code It leads me to SAPMSSCD mainline and there is some heavy logic for getting the output onto the screen using an OTF table.I am really not able to figure out how and where do I get this new field to populate in the OTF table with the existing logic..or do I need to modify the inbuilt coding or is there any other efficient way.
    Thanks,
    Nipun

    hi Nipun to you found some solution for your problem. Iwant to know how to change the language of the sapcript...the short profile appears in English and i want in Portuguese. let me know if you found something.
    regards
    Mário

  • PDFs not created using  Acrobat fail to read in PB20 short profile

    In our ECC system, when trying to read an applicant resume in PB20 (Short Profile->ArchiveLink Object Hit List), we get an error when trying to load someone's resume in which the resume that is saved as a PDF but created in something other than Acrobat (Example: MS Word-->Save as PDF):
    In SDV-->  "The file is damaged and could not be repaired"
    Can anyone offer any suggestions as how to fix this?

    Well, I tried a quick test of the Save As Excel and also Word and the conversion replaces hyphens with bullets; -$20,083.86 becomes •$20,083.86 and 18-JUN-2013 becomes 18•JUN•2013
    I can work with this if I have to, but it certainly is a cludgy approach.
    Do you happen to know if there's a routine in the VB-accessible SDK that allows me to fetch a block of text without any parsing by the SDK? That is, if I could read the contents of the PDF as a stream of characters and do my own parsing, perhaps I could see the hyphens.

  • Logical system for client 001 for SAP NETWEAVER ABAP TRIAL VERSION for BI

    Hi,
    I have installed SAP NETWEAVER ABAP TRIAL VERSION for BI. In that I have to create logical system for client 001. I have taken a list of available clients from the abap R3 side. Here is a list of it.
    Clients View
    Cl. Name City Crcy
    000 SAP AG Konzern Walldorf EUR
    001 Auslieferungsmandant R11 Kundstadt USD
    066 Test EarlyWatch Profiles Walldorf EUR
    I cannot get inside the BW side for it asks me to create a logical system for client 001. What to do?
    Kindly help me.
    Kannan

    hi,
    ? First log on to SAP R/3 server connections Go to SCC4 in R/3 & in Scc4 BW server. A screen opens in that logical name of the system would be opened in both (R/3 & BW).
    ? Take notepad in it save .R/3 & BW logical names go to R/3 & click SM59 to create R/3 connections click then a screen opens gives BW logical name in RFC Destination option & give connection. type 3 & give some description & then press enter.
    ? You will get another screen under it then at target host gives BW server name we will get it from BW logon change ID, IP address option & give the system no. The system no go to logon pad just drag it then you will see the name.
    ? Then click on log on securities go to log on give BW server details like No, client user Password. Then save it then click test connection tab if there are errors then it gives yellow color if they are no error the whole thing come as white.
    ? Then click on the Remote Logon then we go to BW server give RFC – SM59 & click create. Then give the server name which is at the bottom right corner give it then give the no, name, password in logon Security save it & test connection & then remote logon.
    ? R/3 - B W - R/3
    ? Logical connection source system connection is used to transfer the data from R/3 to BW. Go to BW system& click RSA1 go to source system option go to top to the source systems right click on it. Then click create then a screens opens then.
    ? PC ?Flat file , DB ? Database
    ? Select the option manual then a screen appears RFC Destination, Logical source name then click OK then it goes to opens other screen save it test connection then remote login then it go back to the then a screen opens then click only activate.
    ? BW ? RS1 ? SOURCE SYSTEM ? CREATE MANUAL AUTOMATIC CELL
    ? R/3 ? Test connections login ? back ? replicate method ? active data R/3 Source system you will able to.
    hope it helps u
    Ramesh

  • ABAP runtime error for 0CRM_OPPT_H and I while running RSA3

    hello Gurus,
         I'm having problems while running RSA3 transaction for these data sources.
    0CRM_OPPT_H
    0CRM_OPPT_I
    0CRM_SALES_ACT_1
    0CRM_SALES_ACT_I.
    I'm getting ABAP runtime error for these.
    This is the error:
    Runtime Error          CALL_FUNCTION_CONFLICT_TAB_TYP
    Exception              CX_SY_DYN_CALL_ILLEGAL_TYPE
    I tried finding OSS notes for these, but I didn’t succeed.
    I activated the data source from RSA5, and then I tried RSA3. That time I got “Errors occurred during extraction”.
    After that I activated delta at BWA5, then I started getting runtime error.
    Even though I activated at BWA5, I am not able to see the data sources at BWA7.
    Am I missing any thing…please guide me through this….
    Thanks
    RKR

    Thanks for your replay... All the DS and related tables are active..
    But wen I tried to re-generate the DS again... this is the warning I'm getting... Any idea why I'm getting this....
    The even-numbered length of the DEC field SAMPLE_QTY_ALLOW can lead to problems
    <b>Message no. R8569</b>
    <b>Diagnosis</b>
    You want to use the field SAMPLE_QTY_ALLOW in the extract structure for DataSource 0CRM_OPPT_I. This field has a field of type 'DEC' (or 'CURR' or 'QUAN') with an even number of characters.
    This can create problems since the length resulting from calculations in ABAP (for example, in extractors or Customer Exits for extraction) is too large to be inserted in the database later (PSA in BW), causing a short dump.
    <b>Procedure</b>
    This warning is only relevant when the maximum length of this field is exceeded during extraction, for example when the field is expanded in the Customer Exit through a calculation.
    More information and a remedy can be found in SAP Note 641744.
    When I search the OSS note, SAP suggesting to apply 883310 note.
    In my company we are using CRM 4.0 servie pak8. SAP suggsting to install service pak 11, but my client is not interested to upgrade to 11 as CRM people are working on service pak 8.
    By any chance we can use specific note which change the ABAP code to solve this problem... Please give me some suggetions...
    Thanks
    RKR

  • Enhancement for Equipment master data

    Hi all
       I want to find an enhancement for Equipment master data. I want to add some customer fields to Equipment data,but i can't find the enhancement.Anybody tell me the Enhancement which be useful for that. thanks.
    BR
    Chris.

    Hi,
    you can add new tab on the screen and provide your custom field on that tab. You have to add a new tab for any Technical Object by doing some configuration changes in SPRO. first go to SPRO and in screen sequences add a new tab sequence against the profile. Now in the function group SAPLXTOB you can see this new tab screen. Do your requirements on this screen.
    Reward if useful and get back to me if you need any help.
    Thanks,
    Anil

  • Last computer i was able to make 3 profiles and run 3 windows. each time it asked for the profile when i wanted to start each window. how can i set that up again

    ast computer i was able to make 3 profiles and run 3 windows. each time it asked for the profile when i wanted to start each window. how can i set that up again

    last time some1 set it up for me. i would only have 1 shortcut on my desktop. everytime i clicked on it, it would ask me which profile i wanted. even if i had 1 or 2 of the others open it would still ask me which profile i wanted to open. i want to be able to do it that way again.
    yes i already set up the 3 profiles. but once i open up the one profile, and click on the short cut to open another, it just opens a brwser window with the profile in use. so i could open 10 windows, its only 1 profile, the first profile i used.
    and yes i have the box not checked

  • How to intergrate customer short profile into employee profile page MSS WDA

    Hi
    I have created a z version of SAP_MSS_General_profile and amended some the fieids contained within.
    I can't see where this is referred to in the employee profile application in order to get it to refer to the non-standard version.
    Can anyone help?
    Thanks

    Hi Liz
    Yes I did eventually!
    I had delve right down into the component configuration for the employee profile.  We have "z" versions of everything so via SE80 I went to the configuration of the application configuration zhrmss_emp_over_profile (of the web dynpro applications hrmss_emp_over_profile).  From within this configuration I wnet into the change mode of the component configuration zhrmss_emp_overview_profile_oif.
    On this configuration screen there is another button which says change from which there is a sub-menu - one of the items of which is "global settings".  On the global settings screen there is an option to change the short profile from the default setting of "HRMSS_SHORT_PROFILE_CONF"
    I have also found it useful when trying to change other parameters to drill down in the PCD into our role right down to the iview properties in which parameters are often passed such as ROLE and INSTANCE etc and allocate "z" values there.
    I hope this helps!

  • Enhancement for FK01 PAN No. field

    Hi,
    While creating vendor through FK01 i want to make PAN No. field mandatory which is present in the CIN tab .
    Regards,
    Sujit

    As this question was posed in [Enhancements and Modifications forum|ABAP Switching, Enhancing, and Adapting Standard Programs;, the answer will be
    In  Enhancement, transaction [SMOD|https://www.sdn.sap.com/irj/scn/advancedsearch?cat=sdn_all&query=smodCMOD&adv=true&sdn_author_name=&sortby=cm_rnd_rankvalue], [SAPMF02K|https://www.sdn.sap.com/irj/scn/advancedsearch?cat=sdn_all&query=sapmf02k&adv=true&sdn_author_name=&sortby=cm_rnd_rankvalue], there is an exit for user-checks [EXIT_SAPMF02K_001|https://www.sdn.sap.com/irj/scn/advancedsearch?cat=sdn_all&query=exit_sapmf02k_001&adv=true&sdn_author_name=&sortby=cm_rnd_rankvalue] "Vendors: User Exit for Checks prior to Saving". You should be able to use this exit to add your own checks, via transaction [CMOD|https://www.sdn.sap.com/irj/scn/advancedsearch?cat=sdn_all&query=smodCMOD&adv=true&sdn_author_name=&sortby=cm_rnd_rankvalue].
    Was it posted in [ERP Financials forum|SAP ERP Financials; it could have been
    Call customizing transaction, Accounts Receivable and Accounts Payable; Vendor Accounts, Master Records, Preparations for Creating Vendor Master Records, Define Screen Layout per Company Code (Vendors). There you can define field status for vendor here you can define which fields are required, optional or only displayed. There is also here an option Develop Enhancements for Vendor Master Data which links to CMOD, and with a documentation pointing to the Enhancement SAPMF02K.
    Regards

  • Suggest EnhanceMent For SALES area determination In stock Transfer.

    Suggest EnhanceMent For SALES area determination In stock Transfer.
    V02V0001 Sales area determination for stock transport order Doesnt Work,

    Is user exit required, as the sales area will be different. Incase of Intra company stock transfer the process will be as under:
    Create Purchase Order (ME21N)
    Create Delivery in background (VL04, VL10a, VL10C, etc)
    Change Delivery for picking / packing & PGI (VL02n)
    Create Billing Document (VF01)
    Assumption: Stock Transfer configuration is in place. Assistance can be taken from SAP Best Practices in help.sap.com
    Incase of Inter-company, the process will be as under:
    Create Sales Order (VA01)
    Create Delivery (VL01N, etc)
    Change Delivery (VL02N)
    Create Billing Document (VF01)
    Assumption: Configuration is in place. Assistance can be taken from SAP Best Practices in help.sap.com
    Regards,
    Rajesh Banka

  • Error 7 occurred at Copy in ABAPI Dist New VI Library.vi​- ABAPI Dist Chk for Destinatio​ns.vi- ABA​PI Copy Files and Apply Settings.v​i- EBEP_In​voke_Build​_Engine.vi​- EBUIP_Bu​ild_Invoke​.vi- EBUIP​_Build_Inv​oke.vi.Pro​xyCaller

    When I try to build executables in LabView 8.01 I get message:
    Error 7 occurred at Copy in ABAPI Dist New VI Library.vi->ABAPI Dist Chk for Destinations.vi->ABAPI Copy Files and Apply Settings.vi->EBEP_Invoke_Build_Engine.vi->EBUIP_Bu​ild_Invoke.vi->EBUIP_Build_Invoke.vi.ProxyCaller
    Best Regards

    I got the same error as I tried to build my application, the reason was the string I set for the 'Build specification name' property of my build.
    I changed from '3DC - Dlog Data Compacter ' to '3DC' and it worked afterwards..quite strange behaviour..

  • Configuring group policy for user profiles in Windows Server 2012 R2 Domain

    Requesting some experts advise on configuring group policy for user profiles.
    We will be building new Windows Server 2012 R2 Domain Controllers (Domain of 400 users).
    The settings which I am concerned:
    1. Folder Redirection: Desktop, Documents, Favorites.
    2. Quota for Folder Redirection - 1 GB per user.
    3. Map a networked drive - 1 GB per user.
    4. Roaming profile - (Will ignore if it does not suit our requirement). 
    The question is how outlook profile will be retained / automatically moved if the users move from once computer to other?
    FYI, E-mails hosted on MS Office365 and OST file size of few users more than 25GB. So, in case the user moves from one computer to other, the entire mailbox will be downloaded via internet. This consumes high bandwidth if more than 3-4 users shift per day.
    Thanks a lot for your valuable time and efforts.

    Hi,
    >>The question is how outlook profile will be retained / automatically moved if the users move from once computer to other?
    This depends on where our outlook data files are stored. If these data files are stored under
    drive:\Users\<username>\AppData\Local, then these files can’t be redirected, for folder redirection can’t redirect appdata local or locallow.
    However, regarding your question, we can refer to the following thread to find the solution.
    Roam outlook profiles without roaming profiles
    http://social.technet.microsoft.com/Forums/office/en-US/3908b8e0-8f44-4a34-8eb5-5a024df3463e/roam-outlook-profiles-without-roaming-profiles
    In addition, regarding how to configure folder redirection, the following article can be referred to for more information.
    Configuring Folder Redirection
    http://technet.microsoft.com/library/cc786749.aspx
    Hope it helps.
    Best regards,
    Frank Shen

  • Is it possible to change proxy settings for all profiles that´s created instead of the standard options. We need to change "use systems proxy" into "automatic"

    Proxy Problems
    We need to be able to change the default settings for the proxy for all profiles on our computers that´s created for new users.
    Standard is that firefox takes the option "use the system options" for the proxy. We would like it to use the option "automatic" instead like IE and Chrome does.
    Considering that we have over 500 computers doing this manually isn´t an option, because a new profile is created everytime someone logs on to a computer they haven´t used before.

    You can use a mozilla.cfg file in the Firefox program folder to lock prefs or specify new default values.
    Place a file local-settings.js in the defaultspref folder where you also find the file channel-prefs.js to specify using mozilla.cfg.
    pref("general.config.filename", "mozilla.cfg");
    pref("general.config.obscure_value", 0); // use this to disable the byte-shift
    See:
    *http://kb.mozillazine.org/Locking_preferences
    You can use these functions in mozilla.cfg:
    defaultPref(); // set new default value
    pref(); // set pref, but allow changes in current session
    lockPref(); // lock pref, disallow changes
    This will work for all existing and newly created profiles.

  • Can't add a new vNIC for service profile

    Hello,
    I'm trying to add an additional vNIC for Service Profile.
    B200-M3, VIC1240+expander, IOM 2208XP, 4 links between IOM and FI 6248, firmware 2.2(1f).
    At the moment 7 vNICs are configured for this service profile. Service profile is associated with blade server.
    When I try to add a new vNIC (it will be 8th vNIC), I see the error (see the attachment).
    For some reasons separate vNICs are more useful for Hyper-V servers :)
    All vNICs created via vNIC templates. All vNICs configured as VMQ, only iSCSI configured as Dynamic,
    As I read the spec, VIC1240 can support up to 250 vNICs. What is wrong ? How to fix that ?

    I have seen the VMQ limit being reached when applying the VMQ policy to the vNIC template. Can you try not selecting the VMQ policy for these new vNICs. If this works, you might be reaching the VMQ limits as described below:
    Number of VMQ's:
    128 is the Maximum number per vNIC
    256 is the max number per Blade

Maybe you are looking for

  • Interested by performance issue ?  Read this !  If you can explain, you're a master Jedi !

    This is the question we will try to answer... What si the bottle neck (hardware) of Adobe Premiere Pro CS6 I used PPBM5 as a benchmark testing template. All the data and log as been collected using performance counter First of all, describe my comput

  • Exception on JaxRpc invoke: HTTP transport error: javax.xml.soap.SOAPExcept

    Hi all, I am getting below error while invoking Siebel web service from BPEL service, <fault> -<remoteFault xmlns="http://schemas.oracle.com/bpel/extension"> -<part name="summary"> <summary> exception on JaxRpc invoke: HTTP transport error: javax.xml

  • Word processing on mac?

    I'm a relatively new mac user, and I'm just wondering if anyone can tell me if the MacBook comes with any kind of word processing capabilities, because I am a poor college student and can't afford to buy Microsoft Office, unless I have to. If anyone

  • How do i load a set of backing tracks

    I'm brand new to Mainstage and I'm sure the question has been asked before but I want to put my band's backing tracks in a set. I've seen how it should look, but I haven't found exactly how to di it. I have WAV files ready to go. Just need the how to

  • 512 MB or 1 GB graphic card memory for PS CS5?

    To make use of acceleration by the GPU in Photoshop CS5 Extended, to what extent is the amount of graphic card memory needed influenced by the size of the image file? I am aware of the stated 128MB minimum, "256 MB or more" recommendation for graphic