About n1000v with port channel

there is a n1000v connected to multiple upstream switches in the customer's production environment.
the following is from the Cisco Nexus 1000V Interface Configuration Guide, Release4.2(1)SV2(2.1).
You use vPC-HM mode to create a port channel when the switch is connected to multiple upstream switches
that are not clustered.
my question is,
can I use LACP with multiple upstream switches that are not clustered?
can I use LACP with multiple upstream switches that are stacked?
if I stack multiple upstream switches,does it mean clustered?
thanks.

Hi,
See some of the guidelines:
Guidelines and Limitations
Port channeling has the following guidelines and restrictions:
•All ports in the port channel must be in the same Cisco Nexus 1000V module; you cannot configure port channels across Cisco Nexus 1000V modules.
•Port channels can be formed with multiple upstream links only when they satisfy the compatibility requirements and under the following conditions:
–The uplinks from the host are going to the same upstream switch.
–The uplinks from the host going to multiple upstream switches are configured with vPC-HM.
•You can configure multiple port channels on a device.
•After you configure a port channel, the configuration that you apply to the port channel interface affects the port channel member ports. The configuration that you apply to the member ports affects only the member port where you apply the configuration.
•You must remove the port security information from a port before you can add that port to a port channel. Similarly, you cannot apply the port security configuration to a port that is a member of a channel group.
•You can configure ports that belong to a port channel group as PVLAN ports.
•Any configuration changes that you apply to the port channel is applied to every member interface of that port channel.
•Channel member ports cannot be a source or destination SPAN port.
That said LACP should work on switches that are not clustered and meet the conditions above.
A stack is treated as one unit which means that would be like you have just one big chassis.
Stacking does not the same as clustering it works different. so if you stack them that would be a stack not a cluster
http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4/interface/configuration/guide/n1000v_if_5portchannel.html#wp1270746
Hope this helps.

Similar Messages

  • Possible to use inline mode with Port Channel

    Hi,
    Just wondering if anyone has used inline mode with Port Channel configuration placing WAE device between router and switch. Any tips or gotcahs to be concerned about. We currently have inline mode running at this location but site would want redudancy built in through port channel.
    kind regards,
    Nigel

    Hi Nigel,
    This is not supported :
    Taken from here :
    http://www.cisco.com/c/en/us/td/docs/app_ntwk_services/waas/waas/v531/command/reference/cmdr/glob_cfg.html#wp1532575
    Best regards
    Finn Poulsen

  • Win2003 ServerIssues with Port Channel?

    Hello all. I have had 2 different Windows 2003 Servers with Teamed 1000MB NICs have trouble when connecting to a port channel on a 4507. The server is not pingable while connected to the port channel. Once I remove the 2 interfaces from the port channel, communication is back up. I do see that when looking at the mac-address table for one of the interfaces in the port channel it shows both the virtual MAC of the teamed NICs and the physical mac of the NIC. This seems to be an issue but does not happen with any of our Windows 2000 Servers. They only show the virtual MAC when looking at the table.
    Any information on this issue is appreciated. It may be more of a Windows problem than Cisco but I will check both.

    Hello,
    which NICs do you have (brand) ? Not sure if this helps, but what if you configure port security on both ports of the 4507, allowing only the virtual MAC address ?
    Regards,
    GP

  • Stacking 3750s and Port Channel

    We're replacing legacy switches with 3750s in the coming months, and I have a question about stacking and port channel.
    The 3750s will be Layer 2 switches, and each will be uplinked via Gigabit fiber to a pair of 6500s acting as Layer 3 distribution switches.
    One thing I'm not sure about is if it will be possible to built Port Channel links for 2, 3, or 4 GB across different switches, or if I can only put Port Channels on the same switch. My understanding is with stacking it appears as one big switch and I can built Port Channels however I want, but am not 100% if this design will work.

    You can certainly configure EtherChannels across different 3750s in the same stack, thus avoiding your single point of failure by having the aggregate ports all in one switch.
    However in the scenario the port channel has to be configured explicitly to ON, PaGP is not supported across stack members.
    3750 stack switches appear as a single logical switch with a single management address. From which you can configure all physical ports. It is important to remember that you configure your switch priorities accordingly in order to govern which switch is your master, and also set a secondary.
    Regards
    Allan.
    Please kindly rate this post if you find this information helpful.

  • Port-channel Problem between Fabric Interconnect and N7K vPC

    Dear all,
    I have a problem with Port-channel Uplink between Fabric Interconnect with N7K using vPC
    This is my network topology for UCS Deployment
    In N7K I has configured vPC for red link and green link, at Fabric Interconnect A I has configured Port-Channel with member is Port 1 and Port 2, uplink is red link. At Fabric Interconnect B, I has configured Port-Channel with member is Port 1 and Port 2, uplink is green link.
    The show interface port-channel on N7K is good, every port-channel is up and have all member. But At Fabric Interconnnect, when I see on UCS Manager, the status of Port-Channel on Fabic A and Fabric B is fault with Additional Info: No operational member. Although all link is link up and I has status of Port-Channel is enable on UCS Manager. When I see the Properties of Port 1, Port 2 on Port-channel, I see the membership status is : individual. This mean port-channel is not up and no membership in this configuration. I want to using port-channel for load balance and plus more bandwidth for uplink to 20Gig. I don't understand why ?
    Please help me resolve this problem, I has send the capture screen of UCS Manager when I show status of Port-channel and Port-member in port-channel in attach items.
    Anyone can help me to resolve this, thanks you very much. Please reference attach items for more detail about fault.
    Thanks,
    Trung.

    Thanks Matthew very much,
    I has resolved this problem. The reason of problem is miss match protocol of port-channel between N7K and Fabric Interconnect. The Fabric Interconnect always use LACP protocol, but N7K using Port-channel mode on, that why the port-channel failed. I has configured LACP for port-channel in N7K, it has resolved the problems.
    Thanks,
    Trung.

  • 2960x port channel bandwidth command workaround

    Folks:
    I am looking for a work around - Currently I have a four member 2960x switch stack - I have Ten 1/0/1 and Ten 3/0/1 in a port-channel; however, when I try to set the 'bandwidth' on PO1 interface to 20000000 I receive an error, which corresponds being out of range, due to the links being 10Gbps.
    Is there a work around so my PO1 interface reflects the correct bandwidth?
    Switch I am using and version of software
    Switch Ports Model              SW Version            SW Image
    *    1 52    WS-C2960X-48TD-L   15.0(2)EX5            C2960X-UNIVERSALK9-M
    Thank you
    JJ

    The tx-/rxload is probably the least of your problems. Assuming we're talking about a L2 port-channel the interface BW is base for spanning tree cost calculation. With a BW 10000000 kbit/s STP would consider the port-channel equal to a single 10GE link and could possibly decide to block your port-channel for a less favorable link.
    That being said, the port-channel is supposed to have the correct BW corresponding to the number of bundled links without any need for manual user configuration.
    I suppose it is either a software bug or there is an interface not bundled correctly. 
    Post the result of 'show etherc sum' here to check.
    Regards

  • Port Channel Best Practice

    Hi All,
    I have a MDS9509 with port channels going to my Cisco blade switches on my HP Proliant blade enclosure.
    I have NO ports left on my MDS9509, but DO have some remaining on the blade enclosure.
    The question is, can i port channel from the blade enclosure to another edge switch (MDS9148)?
    Is that a supported configuration/Best Practice and what are the ramifications if I do that?
    So I'm going from Core, to edge and then to edge switch with port channel.
    Thanks,
    Matt

    Hi Matthew,
    Sorry for the misunderstanding,  your to-be diagram cleared up a lot for me :-)
    First off, yes, it will work. There's no reason it shouldn't and if you have the external ports free on your 9124e, you can hook up a new switch.
    It's far from a conventional design, because blade switches are supposed to go in the Edge. It's not a best practice.
    What I would recommend is that you move some of the storage from your edge to the 9148, and treat it as a collapsed core, sharing an edge switch (the blade switch).  You can then ISL the 9148 and the 9509 together into a somewhat sensible topology.
    So for one fabric this would be
    (disk)---9148  --- 9509 -- (disks) (some moved to the left to free up space for ISLs)
                    9124e
    Or you can contact your sales team and look to swap some Linecards with higher port density ones.
    Lastly I would like to note that, however you link up the switches, most combinations available to you will 'work'.  So as a temp solution you can go ahead with the (core - blade - edge) scenario.  Just know that you'll be introducing bottlenecks and potential weak points into your network. 

  • VSS port channel options

    Hi,
    I am converting 2 6500 chassis to VSS, currently they are configured as primary & backup. Downstream switch have 4 uplinks,  2 to each chassis with port channels. After I convert to VSS I will have all 4 ports connecting to downstream switch in a port channel, can I keep 2 separate port channels on downstream switch or will it cause issues ?
    thanks
    hasrat

    Hi Hazrat,
    I agree with Reza. By the way what is at your mind in keeping 2 seperate port-channels to one device?(please note after VSS logically it is one switch). One of the Port-channel will not be used at all since spanning tree will block it. So as Reza said bundle them in all one.
    Thanks,
    Madhu

  • Fabric Port Channel

    Hello,
    Once in production, when adding cables in a Fabric PortChannel between an IOM and a FI, ¿is it needed to re-ack the chassis? (so that, we'll have downtime of the whole chassis). Or rather, as it is a Port-Channel the cables are detected automatically, so that it is not needed to re-ack, and so there's no downtime at all...which one is the correct statement?
    Thanks,

    Hello,
    Let us consider following scenario on adding or removing links to existing deployment.
    Initial deployment
    UCSM 2.0, FI 62XX ,2208 IOM and 2 physical links with port channel configuration ( 2 link discovery policy )
    Change
    1) If additional links are added and if they need to be utilized and part of port channel, we need to re-ack the chassis.
    2) If a link goes down,traffic is distributed across other links in port channel and does not require re-ack. Parameters like bandwidth, VIF ports that are calculated based on initial configuration remains the same.
    3) If we physically remove the additional links between IOM / FI, re-acknowledment would create port-channel with original two links.Failure to re-ack will create over subscription ( bandwidth, available VIF ports ) of the network links.Re-ack is not mandatory but it creates appropriate configuration that matches required design criteria.
    Caution
    Adding or removing links  from a fabric port channel is disruptive and may affect the available amount of VIF namespace.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html#concept_5D3D88341BFB43468B62B5A77876C67B
    Padma

  • Port-channel bundled/unbundled

    Is this bundled or not bundled, is what I'm trying to confirm.
    I get two conflicting messages about, if the port-channel bundle is working or not working. (There is traffic on two channels intended to bundled)
    Version 12.2
    Switch1
    Config on port 1/1 is encap 820.1q, node (defaul?)
    Config on port 9/1 is encap (default?) ,and mode trunk
    Switch1 and Switch2 configs are similar
    Switch1 extracts
    Switch1>sh int po 1 eth
    Age of the Port-channel = 01d:04h:02m:05s
    Logical slot/port = 14/1 Number of ports = 2
    GC = 0x00010001 HotStandBy port = null
    Port state = Port-channel Ag-Inuse
    Protocol = PAgP
    Ports in the Port-channel:
    Index Load Port EC state No of bits
    ------+------+------+------------------+-----------
    0 55 Gi1/1 Desirable-Sl 4
    1 AA Gi9/1 Desirable-Sl 4
    Time since last port bundled: 01d:03h:45m:47s Gi9/1
    Time since last port Un-bundled: 01d:03h:57m:35s Gi9/1
    =======================================
    Switch1>sh int g9/1 trunk
    Port Mode Encapsulation Status Native vlan
    Gi9/1 on 802.1q trunk-inbndl 1
    (Po1)
    =========================================
    Switch1#sh runn int port-channel 1
    Building configuration...
    Current configuration : 160 bytes
    interface Port-channel1
    description EC TO ESW002 G1/1,G9/1
    switchport
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 200-202,301
    end
    Switch1#sh run int g1/1
    Building configuration...
    Current configuration : 189 bytes
    interface GigabitEthernet1/1
    description To ESW002 G1/1
    switchport
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 200-202,301
    channel-group 1 mode desirable
    end
    Switch1#sh run int g9/1
    Building configuration...
    Current configuration : 173 bytes
    interface GigabitEthernet9/1
    description to ESW002 9/1
    switchport
    switchport trunk allowed vlan 200-202,301
    switchport mode trunk
    channel-group 1 mode desirable
    end

    You have setup a trunked etherchannel and it appears to be working correctly. this info tells you that the channel is working correctly, to check the trunk do a "show int trunk" also.
    Switch1 extracts
    Switch1>sh int po 1 eth
    Age of the Port-channel = 01d:04h:02m:05s
    Logical slot/port = 14/1 Number of ports = 2
    GC = 0x00010001 HotStandBy port = null
    Port state = Port-channel Ag-Inuse
    Protocol = PAgP
    Ports in the Port-channel:
    Index Load Port EC state No of bits
    ------+------+------+------------------+-----------
    0 55 Gi1/1 Desirable-Sl 4
    1 AA Gi9/1 Desirable-Sl 4

  • Port channel issue in ASA

    We have two Cisco ASA 55XX Firewalls and both are in HA (Active/Standy). Two ports from each Firewall is connecting two ports of Nexus 5K Switch and running port channel between Firewall & Nexus Switch and port-channel is UP. And Switches having back to back connection with allowed all VLAN trunk port.
    FW01 ----------------- SW01 (Two ports with Port channel)
    FW02 ----------------- SW02 (Two ports with Port channel)
    I have VLAN 10 with IP Subnet 10.10.10.0/28
    SW01 : 10.10.10.2
    SW02 : 10.10.10.3
    HSRP IP : 10.10.10.1
    FWs :  10.10.10.4 & 10.10.10.5
    Firewall Default Gateway : 10.10.10.1
    Problem : I am not able Ping Firewall IPs from Nexus Switches. When I checked ARP table in Nexus Switch; I have observed that Firealls two IPs having same MAC address; when I checked that MAC address in the Firewall; that MAC address is Port channel interface MAC address.
    This is issue (two IPs learing same MAC address) from ASA.
    How to fix this issue ?
    Thanks
    Venkat

    Hi,
    What version of IOS are you running on the ASAs?
    see table-12-3 in this link:
    http://www.cisco.com/c/en/us/td/docs/security/asa/asa84/configuration/guide/asa_84_cli_config/interface_start.html
    Also, since the 4500x are in VSS mode, you need to bundle one link from each switch and use LACP.
    HTH

  • How to configure a port channel with VLAN trunking (and make it work..)

    We're trying to configure a port channel group with trunked ports to connect a NetApp HA pair. We want to create two data LIFs and connect them to the switch stack.  We are trying to create 2 data lifs, one for cifs and one for nfs that are on different vlans.
    We want the same ports to be able to allow multiple vlans to communicate. (trunked)
    These data lifs should be able to fail over to different nodes in the HA pair and still be able to communicate on the network.
    What this means is that we have to connect 4 ports each for each node in the NetApp HA Pair to the switches and create a port channel of some type that allows for trunked vlans. When we configure the ports, the configuration is as follows (below):
    We are only able to configure an IP on one of the vlans.
    When we configure an IP from another vlan for the data lif, it does not respond to a ping.
    Does anyone have any idea what I'm doing wrong on the Cisco switch?
    interface GigabitEthernet4/0/12
    description Netapp2-e0a
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet4/0/13
    description Netapp2-e0c
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/12
    description Netapp2-e0b
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/13
    description Netapp2-e0d
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    spanning-tree portfast
    spanning-tree bpduguard enable
    end

    Our problem was fixed by the storage people.  They changed the server end to trunk, and the encapsulation / etherchannel.
    I like all the suggestions, and they probably helped out with the configuration getting this to work.
    Thanks!
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    interface GigabitEthernet4/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet4/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active

  • Cisco MDS port channel with USC FI

    Hello,
    Can anyone help me to configure/troubleshoot Cisco MDS 9148 with Cisco USC ? M stuck in port channel..i have configured but interfaces are not coming UP.It is showing init state.
    My Topology is like,
    Nexus 5000-->USC FI (single FI) -->Cisco MDS 9148
                                                     --> Two Chassis
    Any help would be highly appreciated...
    Thanx

    TMC-UCSFI-A-A(nxos)# sh interface brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/31     1      NP     off     errDisabled      swl    --           --
    fc1/32     1      NP     off     errDisabled      swl    --           --
    Ethernet      VLAN   Type Mode   Status  Reason                   Speed     Port
    Interface                                                                   Ch #
    Eth1/1        1      eth  fabric up      none                        10G(D) --
    Eth1/2        1      eth  fabric up      none                        10G(D) --
    Eth1/3        1      eth  fabric up      none                        10G(D) --
    Eth1/4        1      eth  fabric up      none                        10G(D) --
    Eth1/5        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/6        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/7        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/8        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/9        1      eth  access down    SFP not inserted            10G(D) --
    Eth1/10       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/11       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/12       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/13       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/14       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/15       1      eth  trunk  up      none                        10G(D) 100
    Eth1/16       1      eth  trunk  up      none                        10G(D) 100
    Eth1/17       1      eth  fabric up      none                        10G(D) --
    Eth1/18       1      eth  fabric up      none                        10G(D) --
    Eth1/19       1      eth  fabric up      none                        10G(D) --
    Eth1/20       1      eth  fabric up      none                        10G(D) --
    Eth1/21       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/22       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/23       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/24       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/25       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/26       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/27       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/28       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/29       1      eth  access down    SFP not inserted            10G(D) --
    Eth1/30       1      eth  access down    SFP not inserted            10G(D) --
    output ommitted
    TMC-UCSFI-A-A(nxos)#
    Here it shows that Fc1/31- 32 which are in trunk , status is errdisabled and admin trunk mode is off

  • Write all digitall ports (Channels) with decimal value

    Hi,
    it is possible to write all digital port with a decimal value for a device with 96 channels in the same time?
    I have a USB 6509 device and I want to write each bit whit value 1 in loop (for the first port I write 0,1,2,4,8,16, 32, 64 and 128) with line "Dev3/port0/line0:7", but if I want to write all the ports in the same time how to set the line and the "DAQmx write.vi"?
    Thank you.
    Solved!
    Go to Solution.
    Attachments:
    Untitled 1.vi ‏13 KB

    You can setup reading and writing in 8-bit ports with the 6509.  So you could just write 128 to "Dev3/port0".  If you want to write to all 12 ports, I recommend making a task that is multiple channels on the 6509 module, each channel in the task being a port.  You can then use the Multiple Channel, Single Sample to write your values.  Your values will need to be in an array of U8.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Peer-Switch with vPC and non-vPC Vlan Port-Channels

    Hi,                 
    in a design guide i have noticed that it is best practice to split vPC and non-vPC vlans on different inter-switch port-channels. Now, if i want to use the Peer-Switch function, but the port-channel interface of the non-vPC-vlan channel moves into blocking state. The option spanning-tree pseudo-information has no influence. Is peer-switch possible in my kind of topology?
    Greeting,
    Stephan

    I believe absolutly possible. specifically coz peer-switch and spt pseudo-info are specific and local to cisco fabric services running as part of  vpc technology. Personally me has lab with vpc-domain compounded of 2 N5Ks. They are peer-switches with spt-pseudoinfo and they have MST running on non VPC links independantly from vpc.

Maybe you are looking for

  • Logo flashing on and off after ios upgrading..

    HI, What wrong after upgraded my ipod touch ios the apple logo is continous flashing.. Please help me to solve my problem.. Thank you

  • Stacks for implementing back command!

    This here is my Game class, everything works, but im trying to implement a back command by using stacks. I have imported stacks in and all that...The problem im having is that when i go into another room it adds the room in, but im trying to pop it f

  • Order header text needs to be copied to Invoice Header text

    Dear All,             i am putting some header text in the sales order,i want the same to be copied to the invoice header text,pls guide how to do the same as soon as possible. Regards, AKD

  • Powershell | COMAdmin | $app is null.

    Hi, I have a power shell script which has these lines $comservername="appname" $comAdmin = New-Object -comobject ("COMAdmin.COMAdminCatalog.1") $comAdmin.connect("localhost") $apps = $comAdmin.GetCollection("Applications") $apps.Populate(); $currentd

  • How to embed Skype to my website?

    Hallo guys how can i embend skype to my website I have tried every way in google but am unable please help Post transferred to create new topic; subject/title edited accordingly. Web Developer