Angle and Strain Measurement

Hey Guys,
I'm a LabView newbie and want to program a LabView-VI which should write the measurement of a Heidenhaim angle measurement device and multiple strain gauge strips in one data file like this:
angle | strain1 | strain2 | strain3 ...
The strian gauge strips are connected to the Laptop with NI9237 modules and a NI chassis via USB. The Heidenhaim system is also connected via USB.
Can LabView identify the angle measurement system or do I need additional drivers?
I found this post (http://forums.ni.com/t5/Instrument-Control-GPIB-Serial/Heidenhain-ND-287-connect-with-VISA/td-p/2372... and tried to figure out the given example "Advanced Serial Write and Read.vi". But I would be happy if anybody has more information, examples, codes, etc.
Thanks for your help

Hi,
here is an example to measure the angle with a Heidenhaim device :
http://forums.ni.com/t5/LabVIEW/Angle-Measurement-Using-Absolute-Encoder-and-LabVIEW-FPGA/td-p/14114...
Aurelie

Similar Messages

  • Strain measurement using 9237 and cDAQ 9172

    I am trying to measure strain using a 9237 and cDAQ 9172.
    The strain gage is connected to 9945 (Red wire to EX+, White to IN+ and Black to QTR terminal also tried connected the white and black to IN+ terminal).
    The 9945 is connected to 9237 quarter bridge strain measurement module on a cDAQ 9172. I have two 9237 on the cDAQ 9172.
    The device passes the test in MAX.
    The problem is I cannot read the strain value.
    Can anyone help me please?
    Attachments:
    Strain measure.vi ‏19 KB

    Hi jujare,
    In the VI you attached, you don't have the bridge configuration set up. The default is full bridge I, so if you have a quarter or half bridge wired up, that is one reason you could be getting bad data. I'd suggest you take a look at "Cont Acq Strain Samples(With Calibration)-NI 9237.VI" in the Example Finder. It shows the configuration for bridge type and has some handy wiring diagrams. You could also add controls to your vi to set the bridge configuration if you'd prefer.
    If your strain gauge only has three wires, it's probably a half or quarter bridge. A full bridge needs at least four wires.
    I hope this helps!
    Regards,

  • Load cells and non contact strain measurement

    I am designing a bi-axial machine which meant for a fatigue test.
    Could someone recommend me where to get a dynamic load cells and as well non-contact strain measurement?
    Thanks.

    Hi Alvin788,
    Do you presently use any hardware to measure these or are you enquiring as to what hardware/software you will need? Are you planning to use LabVIEW? The following three links talk about measuring Load Cells as well as Strain Gauges 
    Continuous Acquisition from a Smart TEDS Load Cell Sensor
    How do I Configure a Load Cell in MAX?
    Strain Measurement with a Strain Gauge
    This post will also be highly helpful.

  • Strain measurements using labview and DL750 scopecorder

    Hi
    I want to use labview to do strain measurements using DL750 Yokogawa Scopecorder. I have installed the DL750 drivers and I  can access them from labview, but I am a bit lost as to getting to communicate with the scopecorder, setting up measurements and so on. I am all new to strain measurements and to labview, is there a link or a tutorial that anyone would recommend I refer to?
    Regards, tickle

    Hi Tickle
    It looks like the driver you are using is supported by a third party. I took a look at the driver you are using and it has a couple of examples included with it. I would recommend taking a look at these examples as they are normally a good starting point for communicating with your device. Has anyone else used this device in LabVIEW?
    Best Regards,
    Adam G 
    National Instruments
    Applications Engineer

  • Configuring NI9219 for strain measurement

    Hi!
    I am trying to set-up a strain measurement VI using Labview. I am using NI 9219 module on NI cDAQ 9172 chassis.  My strain gage is configured in a quarter-bridge arrangement and I have made strain gage connection accordingly (to terminals 3 & 5 in NI 9219). However, I do not understand what are TEDS terminals for and what to connect to those terminals. Can I use virtual TEDS for this? I couldn't find a virtual TEDS for NI 9219. Any information in resolving this issue would be highly appreciated.
    Best,
    Nyquist99
    Solved!
    Go to Solution.

    Hi, the TEDS terminals are only for transducers, like a strain gauge, that support TEDS (Transducer Electronic Data Sheet).  The TEDS standard is just the ability of a transducer to save information about itself in internal memory.  This information includes things like calibration constants and dates, scaling factors, electrical characteristics, etc.  It is stored in a standard template which can be read by computers and DAQ cards via those TEDS lines.  For you application, you should just leave them unwired, and setup up your strain gauge normally.
    Chris Bakker
    National Instruments
    Applications Engineer
    Check out LabVIEW 2009 and the New X-series DAQ!

  • I have HP office jet Pro 8500 a premium it is printing at an angle and paper is coming out at angle

    HP office jet 8500A premium operating system Windows 7 no error messages no changes to the product
    The printer is printing at an angle and sending paper out at an angle

    Hi there,
    This article should cover the issue you are experiencing. Give the steps outlined a shot and let us know if it helps.
    Best of Luck!
    You can say thanks by clicking the Kudos Star in my post. If my post resolves your problem, please mark it as Accepted Solution so others can benefit too.

  • Is it possible to adjust the photo angle and size in Snapshots theme

    Hi
    I'm new to aperture and am having a few frustrated-hair-pulling issues with the Snapshots theme. I was using iPhoto to create a Photobook of my son's first year and found it to be too limited for what I want to create. I came across Aperture and was wow'ed by the description saying I could rotate and resize photos, add text boxes etc. This was just what I was after so I downloaded the free trial to test it. I like the snapshots theme the best for the idea of it looking more "homemade" but seem to be unable to adjust the photo angle and size from the given templates. Also I find that the border in adding new photos (which I can adjust the size and rotation of) is without the custom shadow effect that the template ones have. Duplicating the template photo only gives one with the shadow effect but also of the same size with the same rotation that I can't do anything with! Rrrrghhhh
    I thought this would be a great way to customize the album I'm making for my little boy, and that it wouldn't be too hard! My mac skills are considerable, but I'm by no means an expert! Is this program too much for a non-pro-creative-housewife with a wish that may be solveable in iPhoto afterall?
    Or am I just missing something? Is there a way to do this or shall I just give up and choose another theme?
    Any recommendations are welcome! Please!!! My scalp is now officially sore!

    Here's the solution I used to solve the same problem. If you're not comfortable editing the source files, this might be more than you want to take on--but I've done it to several files with no ill effects. You can follow the instructions on this page and the referenced original post from (he includes a link on the page). Good luck! He's got some great tips on some of his other pages.
    http://photo.rwboyer.com/2010/03/15/aperture-3-book-theme-trick/
    A warning about editing the Master pages--it only edits them in that book--it doesn't update the theme. So if you go to create another book with those same layouts, you'll have to duplicate the book and replace all the images. An alternative would be to create a "clean" book with no photos in it and then just use that as a starting point each time.

  • DAQ vi to perform digital write and read measurements using 32 bits binary data saved in a file

    Hi
    DAQ vi to perform digital write and read measurements using 32 bits binary data saved in a file
    Two main
    sections:
    1)     
    Perform
    write and read operations to and fro different spread sheet files, such that
    each file have a single row of 32bits different binary data (analogous to 1D
    array) where the left most bit is the MSB. I don’t want to manually enter the
    32 bits binary data, I want the data written or read just by opening a file
    name saves with the intended data.
          2)     
    And
    by using test patterns implemented using the digital pattern generator or  build digital data functions or otherwise, I need to
    ensure that the     
                binary data written to a spreadsheet file or any supported file type
    then through the NI-USB 6509 is same as the data read.
    I’m aware I can’t use the simulated
    device to read data written to any port but if the write part of the vi works I
    ‘m sure the read part will work on the physical device which I’ll buy later.
    My Plan
    of action
    I’ve
    created a basic write/read file task and a write/read DAQ task for NI USB 6509
    and both combine in a while loop to form a progress VI which I’m confuse of how
    to proceed with the implementation.
    My
    greatest problem is to link both together with the correct functions or operators
    such that there are no syntax/execution errors and thus achieve my intended
    result.
    This
    project is one of my many assignments for my master thesis, so please i’ll
    appreciate every help as I’m not really efficient with LabVIEW programming but
    I prefer it because is fun and interesting if I get to know it.
    Currently I’m
    practicing with LabVIEW 8.6/NI DAQmx 8.8 Demo versions and NI USB 6509
    simulated device.
    Please see
    the attached file for my novice progress, thanks in
    advance for the support
    Rgds
    Paul
    Attachments:
    DIO_write_read DAQ from file.vi ‏17 KB

    What does your file look like?  The DAQmx write is expecting a single U32 value, not an array of I64. 
    Message Edited by vt92 on 09-16-2009 02:42 PM
    "There is a God shaped vacuum in the heart of every man which cannot be filled by any created thing, but only by God, the Creator, made known through Jesus." - Blaise Pascal

  • Fieldpoint and Labview 64 bit - why is the LabVIEW Support missing from MAX and the Measurement I/O Pallette?

    I am running Labview 2010 on a Windows 7 virtual Machine, I have installed Fieldpoint 6.0.7 with all the appropriate support. The VIs are in vi.lib. BUT, MAX doesn't show the LabVIEW support as existing, and the Measurement I/O pallette doesn't have the Fieldpoint VIs linked into it.
    Anyone out there with any idea what I might need to do to get these seen? I've uninstalled, re-installed, installed only sections, and so far - no sign of these VIs appearing.
    So, any ideas?

    Not quite. I can see Fieldpoint, but not the LabVIEW support section.
    The first screenshot is from my 32-bit system, the second is the one from the 64-bit system.
    Attachments:
    Fieldpoint Screenshot 1.JPG ‏20 KB
    Fieldpoint Screenshot 2.JPG ‏15 KB

  • Setting up DAQ system for testing (using pressure transducer, linear position sensor and strain gauges)

    Hello,
    I like to get your suggestion in setting up the DAQ system. I am very beginner in this issue.
    These SCXI listed below are what we have in the laboratory. I will use DAQ card 6062E.
    SCXI 1000
    SCXI 1520
    SCXI 1140
    SCXI 1142
    SCXI 1305 , 1302 , 1300
    SCXI 1122
    SCXI 1100
    I will use linear position sensor in my experiment. But I'm not sure which SCXI shoud I connect to this sensor.
    This sensor gives 4-20mA output. it requires +13 to +28Vdc excitation.
    I will use pressure transducer (strain gauge type) which gives 100mV output and requires 10Vdc supply.
    I will use strain gauges 350 ohm.
    Regarding to the number of channels used in my experiment, I will use 1 channel of pressure transducer, 1 channel of linear position sensor and 3 or 4 strain gauges.
    Could you please suggest me which SCXI should be used with pressure transducer, linear position sensor and strain gauges.
    Now I'm thinking to use SCXI 1520 with strain gauges and pressure transducer. Is that ok?
    But I'm not so sure on the linear position sensor which gives current output.
    And regarding to sampling rate, I like to get minimum of 60-70 KS/s for pressure transducer. And around 1KS/s for linear position sensor and 1KS/s for each channel of strain gauge are enough. Can I archieve these sampling rate from the available SCXI modules mentioned before? I attached the datasheet of pressure transducer and linear position sensor for you. Please see attached files.
    I'm reallly look forward for your suggestion.
    Thank you in advance,
    Ganchai.
    Attachments:
    XPM6_mini. pr. transducer.pdf ‏115 KB
    linear-position-sensor.pdf ‏1683 KB

    Hi Ganchai,
    I would recommend the 1520 with a 1314 terminal block for connecting your pressure transducer and strain gauge. It is designed for excitation, bridge completion and has many other features to fit these applications. For your linear position sensor, try using the 1100 module with an additional precision shunt resistor. For example, our 1308 terminal block has built in 249Ohm shunt resistors for taking current inputs for your 1100. These connections should give you the readings you would like.
    As far as sampling rate goes, you should be fine with your requirements. Good luck and I hope you are succesful.
    PBear
    NI RF

  • RGB and L measurements below histogram suddenly quit

    The RGB and L measurements below the historgram sometimes quit working unexpectedly and give all zeroes wherever the cursor goes on the image.  Quitting Aperture and reopening has usually solved this problem, but I wonder if it's something I'm somehow causing to happen, or it other users have experienced this.

    Thank you.  I have been going back and forth between Pages and Aperture, keeping both applications on the screen, but I hadn't thought to see if the back-and-forth was causing it.  I've been using the viewer.  Is this something that's just a little bug that we need to live with?  Do you close Aperture and reopen as I do to regain the RGB & L values?
    I just did a little test, toggling between Pages and Aperture and then Safari and Aperture, and the loss of RGB&L values did not recur.

  • How to separate the source and the measured current

    Hi Everybody,
    I'd like to know if there is some way to separate the source and the measured current and just writte an mathematical expression to make a dependence between the source and the said parameter. Thanks in advance.

    Sure,
    Here is the deal:
    I'd like to build a circuit with dependent sources, but instead of connecting the sense of current/voltage, I'd like to know if there is a way to writte a sentence for the source which is dependent of a parameter.
    For example:
    In this circuit I just wrote an expression for the source and its respective parameter. (8*Io).
    Attachments:
    images.jpg ‏7 KB

  • Triggering and simultaneous measurements

    Hi everybody 
    I've written a Vi to to acquire data simultaneously from 7 devices. I'll be using cDAQ9178 with NI9203. The vi will acquire current values 4 to 20mA. Could you please check the attached file and let me know if I need to improve it.
    I have some question and I should be grateful if anyone can help me to answer them.
    1. How to open the binary file from write to measurement file by EXCEL?
    2. Is it better to use write to spreadsheet for data logging, if yes how to include the time column??
    3. I'm going to use external signal for triggering through PIF0 port, is it Ok to do that through dag assistance?? I've not tried yet but it seems straightforward?
    4. Finally I have another vi for valve control that should be triggered with the measurement vi, is their any way to do that?? I was thinking about notifiers but I don't know how to use them ?
    Sorry for asking to much  I really in urgent need of all of this. I should finish my data acquisition system by Tuesday 
    Best Regards 
    Solved!
    Go to Solution.
    Attachments:
    triggering and simultaneous measurements.vi ‏97 KB

    1. How to open the binary file from write to measurement file by EXCEL?
    If you select TDMS as the file format in the write to measurement file, you should be able to open it directly from Excel if you install the TDMS Excel Add-In. Be aware that at 1kHz data rate, you will exceed the capability of old versions of Excel to read the entire file in about 65 seconds. Newer versions can read more, but anything over a couple thousand points gets difficult to analyze. That is about my limit. Over this, I go to something else for analysis, such as LabVIEW or Mathematica.
    2. Is it better to use write to spreadsheet for data logging, if yes how to include the time column??
    The write to spreadsheet file is very inefficient for data logging and cannot be recommended. Given your data (an array of waveforms), TDMS is your best bet. The write to measurement file Express VI is the easy way to do this. I, personally, prefer the control I get from using the TDMS API directly. Note that under the hood, the output of the DAQ Assistant is an array of waveforms with individual t0s and dts. The t0s are all different due to the fact that your 9203 is a scanned device, not a simultaneously sampled device. It scans at 200kHz, so the differences are not large, but they are there. I would convert the DDT into an array of waveforms, then use the native TDMS API, but I have a lot of experience. Since you are in a hurry, the Express VI using TDMS is probably your best bet.
    3. I'm going to use external signal for triggering through PIF0 port, is it Ok to do that through dag assistance?? I've not tried yet but it seems straightforward?
    That should work fine. Given your continuous acquisition, the trigger will only start the acquisition, not gate it or trigger it at later times.
    4. Finally I have another vi for valve control that should be triggered with the measurement vi, is their any way to do that?
    We do not have enough information to answer this question. Specifically, how is the valve being triggered (boards being used, hardware interface, software interface). The ideal way would be to run it through the same cDAQ 9178 so that it can be synchronized through hardware. Software synchronization cannot be guaranteed better than about ±50ms. Read up on how to synchronize things through DAQmx and you should be good.
    Good luck!
    This account is no longer active. Contact ShadesOfGray for current posts and information.

  • Amplitude and level measurements for stereo signal

    Hi,
    If I input  my attached stereo file into Express Amplitude and level measurement (blue icon) it does not give me output value as an array. I want to measure peak to peak value for both left and right channels. I get only left channel value. (No array)
    But if I use amplitude and levels.vi I get array as an output for both channels. So i have what I need but I thought I would just post here anyways.
    I have attached my audio file.
    Sheetal
    Thanks.
    CVI 2010
    LabVIEW 2011 SP1
    Vision Builder AI 2011 SP1
    Attachments:
    AUX_HP1_RSA_OFF.zip ‏13 KB

    Sheetal,
    The output of that express vis is of dynamic data type. You need to convert it to a waveform (use the "from ddt.vi") which will then give you the waveform data type. You can then use the "Get Waveform components" to access the "Y" array data.
    Post to let us know if this helped out.
    Chris C
    Chris Cilino
    National Instruments
    LabVIEW Product Marketing Manager
    Certified LabVIEW Architect

  • Encoder Position and Velocity Measurements and Force Measurements

    Hi,
    I am using a USB 6210 DAQ Card and an optical encoder and force transducer together in an MRI room to measure the power ouput of a patient pedalling on a recumbent ergometer. I would like to obtain synchronous measurements and output this to file. I have started working on the code for the encoder. I am struggling to get the frequency measurement and encoder position outputting fast enough. Any idea why this is? For the force measurements will this be with the same configuration just adding Vi's for analog input. Also I know using the write to measurement file vi is quite slow to write to a spreadsheet what is the more efficient method for doing this.
    Regards,
    Darren
    Attachments:
    Angular_Position and RPM.vi ‏46 KB
    Angular_Buffered.vi ‏80 KB

    Hello Darren,
    The fastest file to write to in LabVIEW is a binary file.  The specific file type used by LabVIEW is the Technical Data Management (TDM) file.  The TDMS file is a version of this file specifically designed for streaming applications.  You can find several examples of writing to this file in the NI Example Finder (Click Help -> Find Examples).  By using the search tab, you can use the keyword “TDMS” to search for all of the examples that use the TDMS file type.  The example Cont Acq&Graph Voltage - Write Data to File (TDMS) can be found from the search tab, or by using the path Hardware Input and Output -> Analog Measurements -> Voltage.  While the data acquisition part of this example pertains to analog input, the same file input structure can be used with your counter input tasks. 
    What do you mean that the encoder and frequency measurements are not fast enough?  Each rising edge of the sample clock source will latch the current value of the measurement into the FIFO and transfer this value into the buffer.  At this point, how quickly you can read the buffer will affect how quickly the user is updated with the newest measurement information.  Since you have specified the number of samples to read in your buffered example, the read VI will wait until that many samples are available in the buffer before returning a measurement (this could slow down the update rate for the user).  By specifying -1 as the number of samples to read, you will read all available samples in the buffer.  If there are no samples available, nothing will be returned, but the VI will continue to execute.  Hope this helps. 
    Regards,
    Browning G
    FlexRIO R&D

Maybe you are looking for

  • IPod nano stuck on Apple logo; won't boot.

    I have an iPod nano that seems to charge, but won't boot. There's no sad iPod logo or anything, just the Apple logo. I can boot it into diagnostics mode, and it seems to be fine. However, it won't go into disc mode. Any advice?

  • Did Apple fix the video quality issue in iMovie '09?

    I am a casual video editor and iMovie 08 had the perfect user experience / functionality for what I want to do. However, the known video quality issue (throwing away interlaced scan lines) made the result unacceptable since I archive our family video

  • Third party backup software, how is the log sequence working?

    Me and a colleague had a discussion about how third party software and full backups locally on the SQL works together. If we use TSM that do full backups and then logbackups every hour in between for example. If I between the two full backups from TS

  • TB 24.2; Mac 10.6.8; send & receive problem after upgrade - must click either TWICE or doesen't work. WHY? How to fix?

    I used TB 2 for years with no problems. Got stupid one day and upgraded to 24.2 on Mac OS 10.6.8. Now when I click send I get an error message. After dismissing the error clicking send a second time sends the email normally. The other half of the pro

  • My HP Office jet Pro 8600 plus

    It was in sleep mode, I pressed the power button to wake it. Then pressed it again to power it off. when I went to use it again it wont turn on. Nothing! No lights , power button will not activate anything. I've checked the plugs, cords , power sourc