Application deployment in SCCM 2012

We have a central site and 2 primary sites. I recently notice that deployment policy setup in my Americas site also gets applied to my Europe site. I know in SCCM 2012 a lot of things get replicated across sites but just want to confirm that SCCM deployment
policy also replicates? We usually limit our deployment to workstations within our site but i created a collection with all the workstations globally and was going to create 2 deployments one in each site to target machines within the collection but it looks
like the deployment that i create  within the Americas site also applied to Europe workstations.
Is this native behavior? thanks. 

However, if each site uses unique queries that you target, instead of a common query between each site, then the deployment would not be implemented at the other site as the collection would contain no members. Collections (rules) and deployments do replicate,
but only affect local clients in the targeted collection.
And you can use role-based administration so that admins at one site don't see objects created at other sites.
Wally Mead

Similar Messages

  • How to stop Application deployment in sccm 2012?

    Hi All
    If a application is wrongly deployed to wrong collection in sccm 2012
    how to stop that and where to change settings like we used to do in sccm 2007 we can
    stop it by program properties.

    You have kind of the same feature with Applications in CM2012. You can just right-click an Application, and select "Retire".
    That will change the status of the Application from "Active" to "Retired", and should prevent installations. When you've fixed the problem, you can just "Reinstate" the Application again, and everything should be back to normal.
    But I totally agree with Jason. Make sure you do the proper testing, so you won't have to do this at all :-)
    Ronni Pedersen | Microsoft MVP - ConfigMgr | Blogs:
    www.ronnipedersen.com/ and www.SCUG.dk/ | Twitter
    @ronnipedersen

  • Exe application deployment from SCCM 2012 R2

    Hi,
    is any limitation to deploy the .exe application from SCCM 2012 R2??
    Shailendra Dev

    No limitation. You just need to know how to install it silently. It is a more manual configuration than if you had an MSI.
    Example here
    http://www.gerryhampsoncm.blogspot.ie/2013/03/sccm-2012-sp1-step-by-step-guide-part_20.html
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson

  • Lync 2013 x64 silent client deployment via SCCM 2012 SP1

    Greetings everyone!
    I ran into a problem with Lync 2013 x64 silent deployment.
    I need to provide every workstation with Lync 2013 client, so i decided to use deployment via SCCM 2012 sp1.
    I created 2 msp files with OCT, one based on x86 Office 2013 Proplus, and other based on x64 Office 2013 Proplus.
    Added them as applications to sccm software library.
    Deployment of Lync 2013 x86 application was a success with over than 80% compliance. 
    But all Lync 2013 x64 automatic installations finish with different errors.
    I created special device collection for workstations with office 2010 x64 and 2013 x64, because i can't install other architecture products once it has x64 product installed.
    My membership query-rules for this collection:
    Office 2013 x64
    select SMS_R_SYSTEM.ResourceID,SMS_R_SYSTEM.ResourceType,SMS_R_SYSTEM.Name,SMS_R_SYSTEM.SMSUniqueIdentifier,SMS_R_SYSTEM.ResourceDomainORWorkgroup,SMS_R_SYSTEM.Client from SMS_R_System inner join SMS_G_System_INSTALLED_SOFTWARE on SMS_G_System_INSTALLED_SOFTWARE.ResourceId
    = SMS_R_System.ResourceId where UPPER(SMS_G_System_INSTALLED_SOFTWARE.SoftwareCode) = "{90150000-0011-0000-1000-0000000FF1CE}"
    Office 2010 x64
    select SMS_R_SYSTEM.ResourceID,SMS_R_SYSTEM.ResourceType,SMS_R_SYSTEM.Name,SMS_R_SYSTEM.SMSUniqueIdentifier,SMS_R_SYSTEM.ResourceDomainORWorkgroup,SMS_R_SYSTEM.Client from SMS_R_System inner join SMS_G_System_INSTALLED_SOFTWARE on SMS_G_System_INSTALLED_SOFTWARE.ResourceId
    = SMS_R_System.ResourceId where UPPER(SMS_G_System_INSTALLED_SOFTWARE.SoftwareCode) = "{90140000-0011-0000-1000-0000000FF1CE}"
    My application deployment type points to setup.exe in office 2013 x64 installation folder, where i created msp file in updates folder via OCT and edited config.xml file in proplus.ww folder.
    So my installation program looks like this setup.exe /adminfile updates\1lync.msp /config proplus.ww\config.xml
    The same configuration works with Lync 2013 x86 deployment, except other setup folders.
    When i try running installation program setup.exe with /adminfile and /config parameters locally, it installs successfully without errors or warnings.
    I'm trying to find out problem source, does anyone have ideas what I am doing wrong?
    Also i'm trying to reduce office 2013 installation folder size, what subfolders are necessary for Office 2013 proplus installation (still installing only lync with common files and tools)? Because now 3.5 GB package is quite hard to distribute to sccm secondary
    sites with deployment point.
    Thanks in advance.

    Hi,
    Here are some tips and tricks for your reference.
    Tips and Tricks: Deploying Lync 2013 client using SCCM 2012 | Lync 2013 Client Customization for SCCM 2012 Deployment Package
    http://zahirshahblog.com/2014/01/08/tips-and-tricks-deploying-lync-2013-client-using-sccm-2012-lync-2013-client-customization-for-sccm-2012-deployment-package/
    Note: Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • App-V 5.0 SP2 user applications published via SCCM 2012 to VDI workstations with roaming only

    Hi,
    The environment consists of App-V 5.0 SP2 (KB2956985) user based applications published via SCCM 2012 to Windows 7 VDI snapshotted workstations that are reset at user logoff.
    When a user logs on the SCCM 2012 client initiates App-V client package publishing.  After a couple of minutes after logon the shortcuts appear and the user can launch their applications.
    The issue is that at logoff, even with roaming enabled, the publishing information disappears.  This causes the next logon process for that user to repeat, the applications are not available until the SCCM client has completed it's publishing cycle. 
    Roaming profiles are implemented. %APPDATA% is redirected to a UNC path.  The following registry key is set
    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\AppV\Client\Integration\PreserveUserIntegrationsOnLogin=1
    U-EV, global publishing of applications, and AppLocker rules are not an option.  Also, I have read this already - http://technet.microsoft.com/en-us/library/dn659478.aspx#BKMK_PE
    I do not want to wait for the SCCM client to kick in prior to the user applications being available.  What do I need to roam or run to create a seamless transition for the user between sessions? 
    Eddie.

    Hi Tywin (bad username considering the last GoT Episode ;))
    If you ask Microsoft, they always recommend using SCCM for deploying App-V packages and reuse your current SCCM infrastructure if that is already in place. Problem is, as you now experience, is that there is some big caveats both in regards to publishing
    time and to roaming of settings.
    As Nické states I would suggest looking into the Full Infrastructure Model for App-V 5.x, which gives you much better performance in what I call "from no apps" to "being able to click the shortcut" - the add and publishing phase. If you don't have the time/budget/whatever
    to start looking into that, you could look into some community tools like App-V Scheduler which is developed specific by Citrix guys to ease the publishing and management in a Citrix world.
    Microsoft have a great article about Performance Guidelines, which you have read, but it mostly presumes you work with Full Infrastructure. Have you looked into Steve Thomas' session from TechEd NA? It talks about "implementation trends".
    Senior Consultant at Atea Denmark - http://Atea.dk Atea Technical Evangelist for App-V NoLightPeople - http://NoLightPeople.com Access Director - http://www.nolightpeople.com/index.aspx#accessdirector

  • Is MDT must have for OS deployment in SCCM 2012

    I know that existing MDT could be integrated to a new SCCM.
    Is MDT must have for OS deployment in SCCM 2012 or SCCM has its own engine for OS deployment?
    --- When you hit a wrong note its the next note that makes it good or bad. --- Miles Davis

    Thanks for the answers.
    one more question...
    I am going to start SCCM deployment in test environment.
    For OS deployment part:
    if MDT is planned for integration with SCCM should I configure OS deployment in SCCM before adding MDT.
    Or in this scenario OS deployment in SCCM could not be touched.
    After all previous answers I understand that OS deployment module is part of SCCM installation and is independent from MDT.
    --- When you hit a wrong note its the next note that makes it good or bad. --- Miles Davis

  • How to find who modified Software Update deployment in sccm 2012

    Hi,
    How to find who modified(Date & Time) software update deployment in SCCM 2012 ?

    In the Console :
    Monitoring / System Status / Status Message Query
    Right Click : "Deployments Created, Modified, or Deleted" - Show Message and select your period.
    You'll have your information there.
    Benoit Lecours | Blog: System Center Dudes

  • Office 2013 Professional Plus - 32 bit Deployment takes an unacceptable time to deploy in SCCM 2012 - SP1 CU3

    We recently migrated over to SCCM 2012 SP1 - CU3 the first of the year from SCCM 2007 SP2.  We have used SCCM in the past to deploy Office 2010 and had deployed Office 2013 to our IT Dept. before moving over to SCCM 2012.  The deployment went as
    expected.  Now that we are ready to start deploying Office 2013 to our corporate workstations, the deployment time is running 4.5 hours to 5.5 hours from the local site server DP.  I am afraid to find out what time we are looking at for remote DP's. 
    The three factors that are different is that our SCCM site server is virtual, it is running 2012 for the OS, and obviously SCCM 2012-SP1 - CU3.   We are using the same package source files.   Previous to a successful deployment we were
    seeing hash mismatch errors which MS support pointed us to the nic driver on the VM was using E1000E and to change it to a VMX something driver.
    So I guess my question is anyone else out there deploying Office 2013 ProPlus - 32 bit from this type of environment?  Our previous deployment time for office was a little over an hour (not five hours).  Any suggestions where to look to improve
    the deployment time? 
    I am expected to deploy this in one week and have been working on these issues for weeks.

    I see now that you are using a combination of scripts and ConfigMgr package/program.
    The AppEnforce.log file is for use with the new ConfigMgr Application model.
    Is there any reason that you don't use the new model for deploying Office 2013? It's a single step process and perfect for it. If you use the Office Customisation Tool you can customise what you like. The process will then uninstall Office 2010 and install
    Office 2013.
    This is how you do it
    http://www.gerryhampsoncm.blogspot.ie/2013/03/sccm-2012-sp1-step-by-step-guide-part_9368.html
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson

  • IE11 prereqs deploy via SCCM 2012

    Hi,
    To deploy IE 11 on Windows 7, apparently you need to install 9 prereqs (see http://www.itninja.com/blog/view/how-to-package-internet-explorer-11-x64-for-windows-7-x64): 
    These prereqs are: KB2834140
    KB2670838 KB2639308 KB2533623 KB2731771
    KB2729094 KB2786081 KB2888049 KB2882822
    I don't find the prereqs in red within sccm 2012. Did check the classifications (checked them all in software update point) and did a full sync.
    Please advise howto find/deploy them (I hoped to do this via windows updates and not via seperate packages).
    J.
    Jan Hoedt

    Hi,
    I just checked the first Patch:
    http://support.microsoft.com/kb/2670838
    And there you can find the section: How to obtain this update.
    Is there is Windows Update not noted, you can't receive this Patch through Windows Updates. Consider to deploy the Patch as prerequisite as an application. Here you can find an example of installing hotfixes as prerequisite for the App-V client:
    http://scug.be/sccm/category/detection-methods/
    Detection method is VBScript. Ar you want to create a Detection method with Powershell, refer to this blog post:
    https://sccmfaq.wordpress.com/2013/03/19/sccm-2012-application-detection-with-powershell-and-code-signing/
    Hope this helps.
    www.sccmfaq.ch

  • MS Office Pro 2013 Deployment through SCCM 2012 R2

    Hi Friends,
    I have deployed MS Office Pro 2013 through SCCM 2012. But from Windows 7 Client Machines It's not Installing. Noticed following error in Software Center.
    I'm testing two deployments before bring into production.
    Test Machine 1 :  Purpose = Available 
    From Software Center I have found Test Machine 1 is Status failed.
    Test Machine 2 : Purpose = Required
    From Software Center I have found Test Machine 2 is Status post due-will be retried
    The following Error code is same for both Machines.
    ====================================================
    The software change returned error code 0x87D00607(-2016410105).
    ====================================================
    Any idea please .
    Regards,Ali

    Hi,
    Check out this great guide from Ronni on how to deploy Office 2013 using Configuration Manager 2012, a good read.https://gallery.technet.microsoft.com/office/How-to-Deploying-Office-0f954e7f
    Are the content succefully deployed to all DPs?
    Regards,
    Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec

  • Office 365 ProPlus deployment from SCCM 2012

    hi, I am trying to deploy office 365 proplus using sccm 2012 , everything seems to good, setup.exe run with /configure (path for file). but it is only running nothing installed on systems.
    I used for reference 
    http://www.youtube.com/watch?v=-PNTdap9hwU
    https://sccmguru.wordpress.com/tag/office-365-proplus/
    please help .
    manish yadav

    Hi,
    Please refer to the links below:
    Using Office 365 ProPlus with the Office Deployment Tool
    http://www.petri.com/using-office-365-proplus-with-office-deployment-tool.htm
    How to deploy Office 365 with Click-to-Run and ConfigMgr
    http://www.configmgr.no/2013/06/09/how-to-deploy-office-365-with-click-to-run-and-configmgr/
    Getting started guide for deploying Office 365 ProPlus
    http://technet.microsoft.com/en-us/library/jj839718(v=office.15).aspx
    Note: Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • CRM2013 Silent deployment through SCCM 2012 R2

    Hello.
    First of all im sorry, if im posting in the wrong Forum - but this seemed as the correct one.
    I want to deploy CRM 2013 Outlook Client, through Software center - but i cant seem to get it working.
    I cant seem to find a way, to disable / accept the License Agreement automatically, so that our Domain Users can enjoy a completely silent CRM deployment.
    I have tried several guides, and i have also tried with SetupClient.exe /A - and the "guide" completes, but theCrmClient_32.msi dosent work.
    I would really appreciate, if some of you guys would help me out :)
    We are using SCCM 2012 R2
    Datatechnician

    Looks like you need the /Q switch for this
    http://msdn.microsoft.com/en-us/library/hh699665.aspx
    /Q              
    Quiet mode installation. This parameter requires a configuration file in XML format. The /i parameter contains the name of the XML configuration file. No dialog boxes or error messages will appear on the display screen. To capture error message information,
    include the log file parameter (/L or /LV).
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson
    Hello.
    Ive found the solution my self :)
    SetupClient.exe /quiet /passive /norestart
    I didnt thought that you could have a /q and /p at the same time
    Datatechnician

  • WinPE Error Capture and Deploy Win7 - SCCM 2012 R2 w/ CU1

    Hi Forum
    Deploy and Capture: Windows 7 x64
    SCCM Primary single site server: Server 2012 R2
    Version: SCCM 2012 R2 w/ CU1
    Environment is Hyper-V on Windows 8.1, deploying to a Gen1 VM with a legacy adapter.
    I am running into an issue whilst building a lab environment. I have built a Capture and Deploy TS (using the standard TS, ie not MDT although this is integrated) and deployed to an imported machine using the MAC address via PXE. Custom Client package has
    been created and put against the TS.
    The machine picks up the PXE response and boots into the SCCM WinPE environment and I choose the TS. The only currently available TS is the Build and Capture.
    It runs through the TS restarting at various points as expected and then after the Client Manager package is installed it restarts and runs the TS... at this point it starts saying. "Initiating Hardware Devices.." (or something to that effect).
    It does this for about 15 seconds before I get this error:
    Windows PE initialization failed with error code 0x8022001B
    Seen here:
    I am unable to get the cmd prompt up at this point and it will restart and carry on a normal build, no TS running, meaning no capture.
    If any can advise, please do.
    Thanks in advance
    NN

    Hyper-V should work fine without any drivers injected, and you did your VM correctly.
    During this error, what you see in a back ground, ConfMgr wallpaper or Windows 7 black first-run screen "preparing/first run"? I´m just thinking, is there any chance, that you have additional restart step set to boot to WinPE, instead of booting
    to default OS?
    Otherwise, you will need to be able to Access CMD with F8 for more troubleshooting. Make sure you have F8 command Support enabled on boot image and re-distrubute it. Or create new boot image as Peter suggested.  

  • Lync 2013 client deployment via SCCM 2012 forcing restart

    All, 
    I am attempting to deploy the Lync 2013 x86 client via SCCM 2012 to 158 machines running the Office 2010 suite. My package runs, and the installs complete but they are forcing a restart after the install even though I have gone in to everything that I can
    think of to tell the install not to force a restart. I am a newb in the ways of SCCM so I have been self teaching, and I may have missed something. 
    I have gone into the config.xml and changed the value SETUP_REBOOT to NEVER. 
    In the program properties I have RUN set as HIDDEN, and AFTER RUNNING set to NO ACTION REQUIRED. 
    Is there something that I am missing to stop the users machine from restarting after the install completes?

    Great, unfortunately it will be because files (usually shared DLLs) are in use as Office is opened, despite it being an older version. 
    Agree it's not optimal, I usually just tell clients that they will need to reboot, or that it will push out overnight (when I schedule it) and their computer will restart, so make sure they save everything.
    If this helped you please click "Vote As Helpful" if it answered your question please click "Mark As Answer"
    Georg Thomas | Lync MVP
    Blog www.lynced.com.au | Twitter
    @georgathomas
    Lync Edge Port Check (Beta)

  • Windows 7 Deployment using SCCM 2012

    I am installing Windows 7 Enterprise 64bit on HP Desktops and Laptops using SCCM 2012 task sequence. I captured an image from the reference computer using capture media. The image works fine on Hp Desktops but when I install the same image on HP laptops,
    I get an error message right at the end "Windows Setup could not configure Windows to run on this computer's hardware". I captured another image with plain Windows 7 Enterprise without SP1, updates and drivers. it works perfectly fine on all desktops
    and laptops both. Below is the setupact and setuperr error logs. Much appreciated. 
    SETUPACT.LOG
    capisp.dll::CryptoSysPrep_Specialize: assigned CAPI machine guid "d01b5e9b-0af5-4b3c-a712-70977e79a177"
    2014-08-26 21:19:04, Info                         capisp.dll::SamConnect failed: c00000dc
    2014-08-26 21:19:04, Info                         capisp.dll::CryptoSysPrep_Specialize: DisableAdministratorIfApplicable failed
    2014-08-26 21:19:04, Info                         capisp.dll::CryptoSysPrep_Specialize: returning 65b
    2014-08-26 21:19:04, Error      [0x0f0082] SYSPRP LaunchDll:Failure occurred while executing 'C:\Windows\system32\capisp.dll,CryptoSysPrep_Specialize', returned error code 1627[gle=0x000003e5]
    2014-08-26 21:19:04, Info                  IBS    Callback_Specialize: Internal Providers Specialized Failed. System can't proceed to handle Internal Providers
    2014-08-26 21:19:04, Info                  IBS    Callback_Specialize: Specialize return: [1627]
    2014-08-26 21:19:04, Error      [0x060435] IBS    Callback_Specialize: An error occurred while either deciding if we need to specialize or while specializing; dwRet = 0x65b
    2014-08-26 21:19:04, Info       [0x0640ae] IBSLIB PublishMessage: Publishing message [Windows Setup could not configure Windows to run on this computer's hardware.]
    SETUPERR.LOG
    2014-08-26 21:16:24, Error                 SYSPRP SPPNP: Error 0x25 (CONFIGRET) occurred while determining the buffer size needed to hold the list of devices that are using service usbhub20.
    2014-08-26 21:16:24, Error                 SYSPRP SPPNP: Error 0x424 occurred while opening a handle to the service usbhub20.[gle=0x00000424]
    2014-08-26 21:19:04, Error      [0x0f0082] SYSPRP LaunchDll:Failure occurred while executing 'C:\Windows\system32\capisp.dll,CryptoSysPrep_Specialize', returned error code 1627[gle=0x000003e5]
    2014-08-26 21:19:04, Error      [0x060435] IBS    Callback_Specialize: An error occurred while either deciding if we need to specialize or while specializing; dwRet = 0x65b

    Hi,
    From your error log, we could see the root is the incorrect driver.
    How did you get the driver in your first image? If you enable "PersistAllDeviceInstalls" configuration when you capture the image, all Plug and Play devices in reference computer are uninstalled during the generalize pass and then reinstalled
    during the specialize pass.
    However, it‘s not always applied to your laptop.
    Thus I suggest you download the proper driver or change the BIOS hard disk drive setting to IDE to check the result.
    Warning: This procedure may involve changing your hard disk drive settings in the BIOS. Incorrect changes to the BIOS of your computer can result in serious problems. Microsoft cannot guarantee that problems that result from changes to the
    BIOS can be resolved. Change the BIOS settings at your own risk. Incorrect or corrupted BIOS settings can cause startup problems or shutdown problems.
    In addition, you could refer to the article below:
    “Windows Setup could not configure Windows on this computer’s hardware” installation error on a Windows 7-based or a Windows Server 2008 R2-based computer
    http://support.microsoft.com/kb/2466753/en-us
    Karen Hu
    TechNet Community Support

Maybe you are looking for

  • Setting END_DATE in OWB 11g R1/R2 SCD type 2

    Hi I have this issue which needs an immediate solution. The SCD2 design in OWB 11g R1/R2 works well except that it does not allow a programmer to populate the value of END_DATE with a field from source. I observed that one can set the value of end_da

  • The sound on my macbook air isn't working how can i fix this

    i was on line and i went to watch a video and the sound wasnt working and it still wont work everything is on but its not working out

  • DHCP Client does not send host name to DHCP Server

    Hello, I installed Solaris 10 on VirtualBox and I cannot ping/ssh/telnet the virtual machine by its host name (even from the host computer) but only by it's ip. I tried everything I could find on internet with no success (I don't want to add the host

  • Keynote 6.5 transparent back ground for video

    Dear Apple, In the previous version of keynote I could make animations which I could export with a transparent back ground, after which I could import these into IMovie and use them as overlays. In keynote 6.5 I cannot find this functionality anymore

  • 4.1 Webi Publication does not have Delivery Rules

    I have created a publication for a Webi report in 4.1 BOE. I noticed that the publication does not have an option for Delivery Rules, which is available for Crystal Reports. I'm not sure if that is by Design, as I don't know why it would be available