Batch serial number in TestStand Batch Model

Hello, I want to have Batch Model, after entering the Batch SN and the test sockets SN , execute the main sequence  for the UUT , then create a folder with the batch no and insert the Test Socket SN under that folder .
The process should repeat for the remaining UUTs SN one at a time inserting SN folders under the Batch SN folder at each completion.
I have a LV vi routine that takes care of the creation of the folders by looking for SN Global variables I assign from the Pre-UUT callback parameters.
Problem is Batch SN does not propagate to main sequence  and main sequence only  executes once for the first UUT SN, seems only first test socket executes.
How can I setup this correctly?
TIA
Solved!
Go to Solution.

You can use a Station Global for this.  Modify the Write the Batch SN to a Station Global, then you can access it from any other sequence that you wish. 
Mark E.
National Instruments
Schedule a Free 1-Hour online LabVIEW Tutorial with an NI Applications Engineer

Similar Messages

  • How do you add an additional serial number to TestStand logfile name?

    I have two boards that are tested as a pair and I would like to have the log name show both serial numbers for tracking purposes. The logfile name is currently set up to show the serial number of the mainboard.  I put the second serial number into a StationGlobal after it is scanned it in. How can I add the second serial number to the logfile name?
    Thanks
    Tracey

    Hi vocollect,
    I have found a Community Example that demonstrates how to modify the report name in Report Options. The pictures may not show exactly what you see If you are using TestStand 2012, but the steps are essentially the same. I hope this helps!
    How to Add User Information to a Report Name: https://decibel.ni.com/content/docs/DOC-21744
    Regards,
    Jason D
    Applications Engineer
    National Instruments

  • How do I 'grab' a copy of the current UUT Serial Number within TestStand?

    I am trying to access the UUT Serial Number typed in at the start of each UUT Test Run, in TestStand, so that I can write it to a pre-defined Database. How can I do this?

    Hi,
    You can obtain the SerialNumber by using the lookup RunState.Caller.Locals.UUT.SerialNumber, I am assuming you will be doing this from somewhere within the MainSequence.
    I have attached a TS3.0 SequenceFile, it obtains the SerialNumber and displays it in a message popup.
    Regards
    Ray Farmer
    Regards
    Ray Farmer
    Attachments:
    GetSerialNumber.seq ‏23 KB

  • HT2452 My serial number is odd, which model do I have?

    My iMac S/N starts with a "W" ???
    I cant find that listed

    Serial Number  W80****DB6
    27" iMac mid 2010 flavor
    Barry
    <Edited by Host>

  • Re: Serial number not detected of my Satellite L

    Good evening Dear
    I'am Harris. With you regarding my laptop i buy from UAE.
    Many time i try to detect the serial number from system itself but not dedecting.
    Also try to put the serial number feeded, than message coming your model can't recogonize from data base.
    What the matter in this case please assisit.
    May time i have small problem and try to contact the TOSHIBA help line but hopeless, there no replay from Toshiba helpline or i can't any-one on helpline what surprise this.....
    Your earlier action highly appreciated.
    Thanking you
    Reards.
    Harris.M.
    My user name is harris7 in Toshiba profile.

    Good evening Sir,
    I read your msg & it is saying not clear the content from my msg. My problem is i purchase one Laptop on June and it is registred already some time wanted to check or put come complinet to you i mean Toshiba help desk than Help desk will ask the System Serial no. as well Model no. but manualy given it is not recoganize itself and saying "sorry Serial Number not dedected" or Model Number not dedected system itself I giving my full details below it is Model L505-14U SATELLITE, Serial No. 4A464799K, Part Nunber of Model is PSLS9E-02P002AR. Now tell me what worng with this system to dedect the model number or serial number automatic dedection of itself.
    I have some problem about the mic and sound system i check near the authorise agent they said no sight repair also give to in Dubai, i am staying at Sharjah, not easy to go there from my side suppose i wanted to check and give to collection point they said it will take one week to get back the system. "These are your quick serive" compare other compititer of computer manufacturer.
    One more point i wanted to write here there no help from on-line or e-mail, suppose modern technology not utilize from Toshiba side to reach their millions of customer arround world on finger trip. waiting more days to get proper replay from you. "This is called modern User Friendly Activity".
    Your early action highly appreciated.
    Thanking you.
    Haris.M.

  • Adding batch serial number to report file name in sequential model

    Hi,
    I'm using a Sequential model in TS 4.0 and have learned how to add the UUT serial number to the report file name. But I would like to add the batch serial number instead. Is this possible? Any modifications to the ReportOptions callback seem to only modify the temp report name.
    Thanks!
    Chris

    Hi Chris,
    While Paul's suggestion may be useful in this case, if you would like the flexibility of customizing your Report File Pathnames further, you may want to consider upgrading to TestStand 4.2.
    In TestStand 4.2 we introduced predefined macros and the ability to use custom expressions to specify the Report File Pathname. For example, the <Batch> macro will add the Batch Serial Number to the Report File Pathname as you specify it.
    Please see the Using Expressions to Customize Report File Paths section of the TestStand 4.2 Reference Manual for more information on these new reporting features and how one might use them. For a specific explanation of the different macros and what they might be used for, please see the Specifying Report File Paths by Expression section of the TestStand 4.2 Online Help.
    Manooch H.
    National Instruments

  • Change UUT serial Number with Single Pass in Batch model

    How do I change the UUT serial Numbers with Single Pass in Batch model ?
    I also like to change the UUT report path, so that each UUT saved in it's own directory.
    TIA
    George Zou
    http://webspace.webring.com/people/og/gtoolbox

    the path to the UUT report can be configured in the report options.
    You can't specify unique path for each UUT in the report options.
    Both report path and UUT serial number are stored in the sequence context during execution. So if you want to know where those variables are located (in order to change their values during runtime), you can set a breakboint in your sequence, change to the variabels tab and do a search for the variables (you perharps have to play around a bit with the searchstring though).
    I've already find the place where TestStand holds the information.  The problem is that there is no proper callback I can override.
    I can only change the serial number in my sequence file.  But that is too late to include the serail number in the report file name.  The serial number inside the report does get changed.
    By the way, I can't change the process model.  User wants out of box batch model.
    Thanks for reply.
    George
    Message Edited by zou on 06-19-2008 08:40 AM
    Message Edited by zou on 06-19-2008 08:43 AM
    George Zou
    http://webspace.webring.com/people/og/gtoolbox

  • Add serial number in the report file name when using batch process model

        I would like to append a string containing the current UUT serial number to the base name of the report file. For example, uut_report.html becomes uut_report[SN000001].html. This setting is not available if I use NI BatchModel.seq as my process model.
    Thanks!
    Jacky

    duplicate post
    Ask your question only once.

  • I want to change serial number in the Batch report and in the special UUT report

    I use Batch Model, sequential mode.
    I want to change serial number in the Batch report and I want to change UUT serial number in each TestSocket report.
    I overrided ModifyReportHeader, I did
    Parameters.UUT.SerialNumber = "....."
    but the serial number changed only in the Batch Report, not in UUT Report. How can I change serial number in UUT Report too?

    Marta,
    There is actually a ModifyBatchReportHeader in addition to the ModifyReportHeader that you already used.  That would be the first thing to do.
    After that, I think I need a more detailed description of what you are trying to do (perhaps with screenshots) in order to be able to help effectively.
    Josh W. | National Instruments | Applications Engineering
    Josh W.
    Certified TestStand Architect
    Formerly blue

  • How to add Serial Number to the batch report name?

    How to format the report name for batch model to have <Sequencename>_<batch_SerialNumber>_<DateTime>.xml. Everytime a different sequence is executed the report file name should be formated with that sequence name and batch serial number porvided. I am using TS4.1
    Sequential model has a Determine Report File Path, is there something similar for batch model also, if so where?
    Thanks.
    CLD,CTD

    Did hit Post too early, here is the remaining,
    For the second part 
    have the serial number of each individual DUTs included in its file name
    The setting in Report Option will also save the UUT report with UUT serial Number included in the following format:
    SeqFileName_[UUT][Date][Time].xml where [UUT] will store the UUT serail number.
    CLD,CTD
    Attachments:
    reportOptions.jpg ‏85 KB

  • UUT serial number is not displayed in batch results popup window?

    UUt serial number is not displayed in batch results popup window. I am using TestStand 2012 SP1 f1 (5.0.1.66). I am also using Prebatch callback and setting up 
    Parameters.ModelData.TestSockets[index].UUT.SerialNumber with the UUT serial number. I have used the exact sequence file with TestStand 4.2 (4.2.0.134) with no problems.

    Sorry for my late reply I was away for work. I actually revisited the code that I implemented with TestStand 4.2 (4.2.0.134) and it is showing the exact problem. Sorry for misleading you. however the UUT report is showing the correct serial number for each unit. This would be something that is nice to have but not critical for my project. I am basically auto discovering all my UUT so instead of scanning the serial number I read it from the UUT memory so there are a lot of steps in my PreBatch call-back but they are all related to reading the UUT serial number. Once I read all the UUTs serial numbers I set the following in a for loop:
    Parameters.ModelData.TestSockets[Locals.For_Loop_Index].UUT.SerialNumber =StationGlobals.UUT_Serial_Numbers[Locals.For_Loop_Index]  
    I tried to implement my a simple PreBatch with only a for loop and an array of serial number and I ended up with the same issue. So I am suspecting that the batch report is getting the serial numbers from a different variable and that variable is set when you run the batch option without the PreBatch call-back.
    Kind Regards,
    Oshana

  • Batch Split for Material which are activated with serial number management

    Hello All,
    We have requirement where we want batch split to be mandatory during goods reciept with inbound delivery  for material which are serial number managed.
    Please let me know the possible solution to achive this requirement.
    Appreciate your quick response.
    BR,
    Tushar

    I have resolved this issue by myself. Check out the link where I have briefed how to resolve the issue using bapi BAPI_OUTB_DELIVERY_CHANGE.
    BAPI_OUTB_DELIVERY_CHANGE - Batch Splits don't work
    Regards,
    Senthil G.

  • Cancel insp.lot for batch material with serial number?

    We have a problem with an inspection lot....
    A few months ago we made a goods receipt for batch material... it ended up in Q- stock.
    The weeks went by and the material was changed ito a serial number material... that process works fine...
    But now we want to scrap the material that is batch-handeled ... the inspection dont want to let go.. it want serial numbers... even if I create serial numbers for this the inspection lot
    dont let me register any numbers.. So I cant cancel/delete it... And after all I just want to scrap the batch...
    Can someone help me?
    // Andreas

    if stock of that material with serial numbers exist, then scrap that stock and disable the serial number for the material by deleting the serial number profile in the work scheduling view of the material master.
    then try cancelling the inspection lot. After cancelling the inspection lot, activate the serial number for that material again and bring back the scrapped stock into the unrestricted use.
    Note: please advice the users not to post any stock for that material till you complete this or else block the posting t.code for all the users.

  • Max. Number of testsockets in batch model

    I haven't found any information about the max. number of testsockets in the batch model. We need to test up to 32 UUT at the same time. The UUTs are not of the same type, so we need to run different test sequences for different UUT types at the same time. We need some synchronization points during the test for changing e. g. the temperature since all UUTs are located together.
    Has anyone any experince with such a number of parallel runinng sequences?
    Can we use different sequences in one batch run for different testsockets?
    I have seen in the documentation that the batch model can divide a sequence into synchronization aereas. Is this the right method to wait for the active testsockets to complete part of the sequence and then to change e. g. the temperature?
    Waldemar
    Using 7.1.1, 8.5.1, 8.6.1, 2009 on XP and RT
    Don't forget to give Kudos to good answers and/or questions

    Waldemar,
    there is no reasonable limit for the amount of TestSockets. But there is of course a limiting factor: the performance of the system, mostly RAM. Running 32 TestSockets shouldn't be a problem if the sum of RAM needed for each UUT does not succeed the available RAM.
    To answer your further questions, you have to learn some things about the parallel/batch model:
    Those models constists of two areas, one for global management and one for each socket. The area for each socket looks a bit like the SequentialModel, but differs due to synchronization issues (report, batch synchronization, ...).
    The other area calls the socket area for each socket as NewExecution, meaning a parted dataspace for each socket. Another thing you have to know: each socket executes exactly the same sequence!
    So the simplest way to accomplish your task is to generate one general sequence which handles all sockets. Using if-statements and precondition, you can then asign certain functions for certain sockets. You can always get the info, which socket is currently active by reading the RunState.TestSocket.MyIndex.
    Synchronization you are looking for is indeed done with the batch-synchronized section.
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • IO 229 - Batch for serial number 1234 (BBB) differs from document batch AAA

    Hello All,
    We use batch management for serialized materials only at our central plant. For all other plants, there is no batch control. Sometimes we need to return materials back to the central plant but with a different batch number.
    When we do two step stock transfer 303 / 305, we receive the following error message if we don't use the original batch number.
    "IO 229 - Batch for serial number 1234 (BBB) differs from document batch AAA".
    However, when we use one step plant to plant stock transfer 301, there is no error message. The batch number is also updated correctly in IQ02.
    I wonder if there is any configuration to use 303 / 305 with different batch numbers.
    Thanks,
    Hakan

    Thanks Arminda.
    64044 recommends to use 309 to change the batch, which works but this is an additional step.
    Currently 1 step plant to plant transfer i.e. 301 doesn't require this additional step. It updates the batch information with no problem.
    Is there any configuration option to change the behavior of 305, so that we don't have to do an additional movement?

Maybe you are looking for

  • My Premiere Pro CS6 crashes everytime, i start a new project?

    Each time this is the message i get, "Sorry, a serious error has occurred that requires Adobe Premiere Pro to shut down. We will attempt to save your current project." Can someone help

  • How to generate the BPEL interface from XSD?

    I am new to the BPEL. How to generate the BPEL interface from XSD because I need the inputed payload to have a complex type instead the simple string? Thank you

  • Command line console, any decent package?

    Hello there: I was given an assignment to write a simple adventure game, command line console is to be used to accept user instructions. While we can create a traditional while-loop to take users' requests, i am wondering if there is any decent packa

  • New iPad Retina display analysis at Anandtech

    A short but interesting article on the new iPad's Retina display from Anandtech: Pixel density: http://www.anandtech.com/show/5689/the-new-ipad-retina-display-analysis/1 50x magnification of pixels: http://www.anandtech.com/show/5689/the-new-ipad-ret

  • Export to excel - number format

    Hi, Our version is SAP ERP Central Component 5.0 and we have just pathed the system from SPS18 to SPS23. However from that time has change the export to excel functionality. Now after you select List - Export - Spreadsheet you can select either Excel