Bug in CF7 built in time validation?

I'm using cfform and cfinput on a textbox, this is what I'm
using to recreate the error:
If I enter a time between 20:00 and 20:59 I get an error,
otherwise as far as I can tell any other time validates.
This error does not happen on our CF6 boxes, just CF7.

thebuddhist -
The problem you are having is a result of a coding error in
the cfform.js file and the
other problem that Dan is indicating, is that a non-valid
time like 20:63 can be entered
and it will process as a valid time.
================================
cfform.js - CFIDE folder - able to change
================================
If you have the ability to change the cfform.js file on the
server then try this:
on or about line 492, you will find some code like below,
change the [1-4]
to [0-3]
var result = _CF_checkregex(object_value,
/^(([0-1]?[0-9]|[2][1-4]) :
([0-5]?[0-9])(:[0-5]?[0-9])?).?([AP]M|[AP]m|[ap]m|[ap]M)?$/,
required);
return result;
===> Change to below:
var result = _CF_checkregex(object_value,
/^(([0-1]?[0-9]|[2][0-3]) :
([0-5]?[0-9])(:[0-5]?[0-9])?).?([AP]M|[AP]m|[ap]m|[ap]M)?$/,
required);
return result;
and all should work fine.
===================================
cfform.js - CFIDE folder - not able to change
===================================
If this is located at a hosting service and they will not
change the cfform.js
to the above, then copy your cfform.js to the same folder as
the form is in
of course with the change made.
Then on the cfform tag, add the following attribute:
scriptsrc="."
Mine is like below:
<cfform action="formname.cfm" method="post"
enctype="multipart/form-data" scriptsrc=".">
This should then call the cfform.js file within the folder
for processing the time elements.
=====================================================================
As for the other problem, this is what I did to work around
it:
On the action page I added this coding:
<cfset MidNight_A =
DateAdd("h",1,CreateTime(23,00,00))>
<cfset MidNight_B =
DateAdd("h",0,CreateTime(00,00,00))>
<cfif #form.StartTime lt #MidNight_A# AND
#form.StartTime# gt #MidNight_B# AND
#form.StopTime# lt #MidNight_A# AND
#Form.StopTime# gt #MidNight_B#>
process time fields
<cfelse>
Valid times were not entered.
</cfif>
This may not be the best practice / prettiest way to work
around the non-valid
time format. However, it seems to function fine for me (so
far). I am certainly
open to suggestions of a better way to accomplish the task if
there is one.
Leonard B

Similar Messages

  • Kernel FireWire (OHCI) Lucent ID 5811 built-in: no valid selfIDs

    so I have 2 firewire drives, 1 is just an external for media, 1 is a Time Machine backup. last night, neither would mount. I tracked it down to a variety of Console.app messages like:
    6/5/08 8:31:01 AM kernel FireWire (OHCI) Lucent ID 5811 built-in: no valid selfIDs for more than 3 minutes after bus reset.
    this morning. a reboot solved the problem, although my time machine drive is DIRT slow. I'm currently trying to determine if it's a hardware issue and if so, where?
    I'll report back with some more troubleshooting this afternoon, I'm just curious if there's any sort of similar problem on other MacBooks. Googling that error message didnt turn up anything recent. I'm hoping its just the cable (I need to track down a new one somewhere in my house!) and not the actual firewire controller. my other hypothesis is a conflict with a 3rd party driver (currently deactivated, does not start on boot) so I'll poke at that later today as well.
    thanks for the help in advance,

    so I have 2 firewire drives, 1 is just an external for media, 1 is a Time Machine backup. last night, neither would mount. I tracked it down to a variety of Console.app messages like:
    6/5/08 8:31:01 AM kernel FireWire (OHCI) Lucent ID 5811 built-in: no valid selfIDs for more than 3 minutes after bus reset.
    this morning. a reboot solved the problem, although my time machine drive is DIRT slow. I'm currently trying to determine if it's a hardware issue and if so, where?
    I'll report back with some more troubleshooting this afternoon, I'm just curious if there's any sort of similar problem on other MacBooks. Googling that error message didnt turn up anything recent. I'm hoping its just the cable (I need to track down a new one somewhere in my house!) and not the actual firewire controller. my other hypothesis is a conflict with a 3rd party driver (currently deactivated, does not start on boot) so I'll poke at that later today as well.
    thanks for the help in advance,

  • Time Validation question

    I am using the time validation and it works well, however my
    case (which I think would be common) doesn't seem to be supported,
    or I am just not sure how to configure. I want someone to enter in
    a time such as '8:45 AM' or '11:30 PM'. It seems as though it
    requires either a leading zero, or a single diget, but not a way to
    do both. The code below allows for the '8:45 PM' option. But not
    11:45 PM.
    <script type="text/javascript">
    var eventtime = new
    Spry.Widget.ValidationTextField("eventtime", "time", {format:"h:mm
    tt", hint:"8:00 AM", validateOn:["blur", "change"],
    useCharacterMasking:true});
    </script>
    The example on this page is forces the leading zero.
    http://labs.adobe.com/technologies/spry/samples/validationwidgets/TextfieldValidationSampl e.html
    Am I missing something or does that pretty much require users
    to always do leading zero in order to enter the full range of
    time?

    The textfield validation widget implementation doesn't
    support variable length for time format. To cover your use-case you
    might use the "hh:mm:tt" format and add the leading zero for single
    digit case.
    The time formats that are accepted are: "HH:mm" (default),
    "HH:mm:ss", "hh:mm tt", "hh:mm:ss tt", "hh:mm t", "hh:mm:ss t".

  • Time validator

    I am trying to come up with some way of producing an applet that will deal with the following:
    In this task you are required to design, create and test a new class called newTime.
    1. Design a solution for a new class called newTime.      
    a. public boolean valid24Time (int hh, int mm)
         The hours (hh) can only be in the range 0-23 and the
    minutes (mm) can only be in the range 0-59.
         This method must return true if the time is valid and false
    if the time is invalid.
         b. public String convert24ToStd (int hh, int mm)
         The time is passed to the method as hours (hh) and minutes
    (mm)with the time in 24
         hour format. The 24 hour format must be changed into standard
    format in the form
         hh:mm AM for a morning time and hh:mm PM for an afternoon time.
         This method must return a string containing the time in
    standard format.
         c. public int convertStdTo24 (String hhmm)
         The time is passed to the method as a string in standard format
    in the form hh:mm
         AM for a morning time and hh:mm PM for an afternoon time. The
    standard format     must be changed into 24 hour format.
         This method must return an integer containing the time in 24
    hour format.
         d. public int addTime (int hh1, int mm1, int hh2, int mm2)
         Two times are passed to the method in 24 hour format as hours
    and minutes (hh1 and mm1, hh2 and mm2). The two times must be
    added together.
         This method returns the calculated time as an integer in 24
    hour format.
         e. public int subtractTime (int hh1, int mm1, int hh2, int mm2)
         Two times are passed to the method in 24 hour format as hours
    and minutes (hh1 and mm1, hh2 and mm2). The second time must be
    subtracted from the first.
         This method must return the calculated time as an integer in 24
    hour format.
    2. Error handling routines must be included to deal with exceptions.
    3. Write the code for the newTime class.
    4. Design and create a testnewTime class which tests the methods in the newTime class.
    Document the layout of any input and output screens used.
    5. Create test data to test the newTime class and determine the expected results.
    6. Prepare a test plan.
    7. Test the software, compare the actual results to the expected results keeping a log for
    each test which identifies any discrepancies between actual and expected results and
    records any amendments made to correct errors.
    8. Produce technical documentation to describe the class interface and purpose and
    operation of the newTime class.
    9. Produce a printed program listing.
    Any help would be grateful
    Regards
    Rary Geddi

    I've have tried all ways to get this to work but with out any luck.
    What am I doing wrong?
    public class Frame1 extends JFrame {
    String inputHour;
    String inputMin;
    int hh = 0;
    int mm = 0;
    boolean isHourValid;
    boolean isMinValid;
    public boolean valid24Time ( int hh, int mm)
    {  boolean isHourValid = ( hh>= 0 && hh<24);
    boolean isMinValid = ( mm>= 0 && mm <60);
    return (isHourValid & isMinValid);
    private JPanel contentPane;
    private JPanel jPanel1 = new JPanel();
    private JButton jButton1 = new JButton();
    private JButton jButton2 = new JButton();
    private JButton jButton3 = new JButton();
    private JButton jButton4 = new JButton();
    private JButton jButton5 = new JButton();
    private GridBagLayout gridBagLayout1 = new GridBagLayout();
    private GridBagLayout gridBagLayout2 = new GridBagLayout();
    void jButton1_actionPerformed(ActionEvent e) {
    inputHour = JOptionPane.showInputDialog("Enter Hour");
    hh = Integer.parseInt(inputHour);
    inputMin = JOptionPane.showInputDialog("Enter minute");
    mm = Integer.parseInt(inputMin);
    if ( isHourValid & isMinValid )
    JOptionPane.showMessageDialog
    (null,"Time invalid" hh mm,"Invalid time", JOptionPane.PLAIN_MESSAGE);
    else
    JOptionPane.showMessageDialog
    (null, "Time valid" hh mm, "Valid time", JOptionPane.PLAIN_MESSAGE);
    }

  • Date and Time validation together...

    Hi,
    I want to have the date and time validation together. Is it posible?
    I am not able to do it using "AT SELECTION-SCREEN".
    e.g.
    DATE1 - DATE2 is 12/22/2009 - 05/27/2010
    TIME1 - TIME2 is 15:00:00 - 01:00:00
    This will result in error because the time1 is more than time2 but it is correct when it is tied to date1.
    I tries to validate them together but it gives the standard error all the time.
    Please help me.
    Thank you.

    Hi,
    You could have a normal range for your date field and two parameters for the times...no?
    SELECTION-SCREEN BEGIN OF LINE.
    SELECTION-SCREEN COMMENT 1(33) ttime FOR FIELD p_time1.
    PARAMETERS: p_time1 type t.
    SELECTION-SCREEN COMMENT 54(2) tto FOR FIELD p_time2.
    SELECTION-SCREEN POSITION 60.
    PARAMETERS: p_time2 TYPE t.
    SELECTION-SCREEN END OF LINE.
    INITIALIZATION.
       ttime = 'Time'.
       tto = 'to'.
    Kr,
    Manu.

  • Bug in "Get and Set Time.vi" example for RT systems

    There is a bug in "Get and Set Time.vi" that ships as an example in the "NI System Monitor" package.  The routine does *NOT* return the hour correctly.
    Note the string "%#H:12:39.371" as the time of day.  That should be 09:12:39.371 as it was 9 AM at the time.
    Mac OS X 10.8.5
    LabVIEW 14-64bit
    NI System Monitor 14.0.1
    Pharlap RT PXI embedded system version 14.0 updated.
    NOTE: it is odd that the default "New Time" has #H as the hour but that is hard wired into the VI as a sentinel case.

    Rahul,
    It may be only in the Mac OS X code base.  But since it is one of those annoying locked VIs I can't tell.  Now of course this is locked because communication with the RT system is so sensitive or just plain messy.  My guess is that if I thow wireshark at it I can tell you what is inside and it shouldn't be that secret.
    But let me know what you find running under Mac OS X.

  • Bug: Built Real-Time app won't run if it accesses a typedef'ed shared variable node

    Hello,
    I finished developing a Real-Time program that uses typedef'ed (clusters and enums) networked shared variables (SVs). It works fine when I run the program in Development mode. However, when I built and deployed it as a start-up app, it refuses to start. The VI monitor in the Distributed System Manager says that the VIs that use those SV nodes (and the top-level VI that references them) have "Bad" status, and the rest are "Idle".
    To get my built program to run, I had to disconnect all the variables from the typedefs. Deleting the SV nodes made the program run too, but that's not an option.
    Has anyone else encountered this?
    Platform: LabVIEW 2012 (32-bit), NI cRIO-9076

    Yes. See the following thread.
    Paolo
    LV 7.0, 7.1, 8.0.1, 2011

  • Certificates Time Validity

    Hello:
    I am facing an issue with my certificates once I generate them using Apple Developer or Android Keytool. I have to wait 5 hours at least to compile my app (look at the screenshot). It happens with the developer certificate, the keystore or the push notifications certificates.
    Any further ideas why this is going on?
    Saludos,

    Yes, this is a known bug with DPS App Builder. You can either wait a few hours before App Builder finally understands that your new certs are valid, or you have change the date/time settings on your computer if you're really in a hurry. Unfortunately, this bug isn't scheduled to be fixed until v27.

  • Bug in Tabular form Not Exist Validation, fails when creating multiple rows

    Hi,
    I have a Not Exist validation created for a Tabular form:
       select 1 from my_table where col1 = :col1 and col2 = :col2Execution State: For created and Modified Rows
    which is working fine when a row already there in DB
    and I am trying to enter a new row with same data.
    but when there's no data and I enter two rows with same data, validation does not fire, first row should allowed to enter
    but for second row it should give error that data already exists, which is not happening.
    for example,
    let's say I have a row in DB with: 1, 2, 3
    when I try to add a new row with same data ie. 1, 2, 3 validation fires and showing error, which is fine.
    but let's say there's no data in DB and I am entering two rows with:
    1, 2, 3
    1, 2, 3
    validation is not working this time, it is allowing to enter both the rows.
    do I need to create a manual validation for this or what?
    Apex 4.1.1.00.23
    Regards,
    Tauceef
    Edited by: Tauceef on Dec 6, 2012 10:09 AM
    Edited by: Tauceef on Dec 6, 2012 11:22 AM
    Edited by: Tauceef on Dec 6, 2012 11:27 AM

    Hello Tauceef,
    >> Now I got it, I was under impression that it will validate one by one row before insertion,
    >> but it's going to check all the rows first, then do the insertion.
    Just to clear things up, the APEX engine works exactly as you describe, but this is your problem.
    The APEX engine do check\validate all the rows first, one row at a time, and only if all the rows pass validation, the DML processes kick in. The DML processes work on the entire Tabular Form record set (per page view, of course).
    In order for your type of validation to work (the one that queries the database), as you want it, the validation and DML actions have to run together, row by row. This is not how things work, because it’s less efficient/optimal, and may lead to a situation where a certain row can fail validation, but other row(s) already been inserted/updated/deleted into/from the database. This could be a very tricky situation.
    Vikram has suggested to rely on a database constraint, and control the APEX error message. This is possible, although I’m not sure that in this case, the Tabular Form will retain all the user changes, in case of validation error. You should check it.
    Another option, which Marc hinted on, is to manipulate the G_Fxx arrays. In your case, you should loop through the new rows, compute their MD5, and make sure that all the rows have different MD5 values. This is on top of the current validation, which makes sure that the new rows do not already exist in the database.
    Regards,
    Arie.
    &diams; Please remember to mark appropriate posts as correct/helpful. For the long run, it will benefit us all.
    &diams; Author of Oracle Application Express 3.2 – The Essentials and More

  • Ethtool bug or driver bug or faulty built-in NIC ?

    First the hardware particulars -
    - The laptop in question is an Acer Aspire 5050 with an AMD x86-64 Turion cpu
    - There is an on-board SATA chip (unused), which throws up some very odd errors but except on slackware distros, seems to do no harm. {It cannot be disabled in the bios either thanks to Acers craptastic bioses.}
    - It has an IDE WD 120gb hard drive and an ATI 200M video chipset (xorg IDs it as an 1100 IGP/465 chip)
    - The NIC in question is: eth0: RealTek RTL8139 at 0xf8848c00, IRQ 18; eth0: Identified 8139 chip type 'RTL-8100B/8139D'.
    - Ethtool reports this in querying the Nic in question:
    Settings for eth0:
    Supported ports: [ TP MII ]
    Supported link modes: 10baseT/Half 10baseT/Full
    100baseT/Half 100baseT/Full
    Supports auto-negotiation: Yes
    Advertised link modes: 10baseT/Half 10baseT/Full
    100baseT/Half 100baseT/Full
    Advertised auto-negotiation: No
    Speed: 10Mb/s
    Duplex: Half
    Port: MII
    PHYAD: 32
    Transceiver: internal
    Auto-negotiation: off
    Supports Wake-on: pumbg
    Wake-on: d
    Current message level: 0x00000007 (7)
    Link detected: no
    Now to the issue at hand
    This is not so much a problem as it is an annoyance really. For whatever reason, on several distros that I have investigated, my on-board nic is incapable of being used at the 100mbit setting it is capable of using.
    Typically when I first boot a distro, the nic is detected and will work fine, however it runs at half-duplex and on 10mb/s. It is capable of full duplex mode & 100mb/s.
    I did alot of research about how I could enable full duplex and 100mb/s modes. I found ethtool to be the answer, or so I thought. However, when ever I've used ethtool, it will set full duplex mode correctly but if I tell it to set the card to use 100mb/s mode, the link itself will not stay up. It insists there is no link detected and restarting the network connection does nothing, as the card never receives an IP address from my router. As soon as I revert the card to 10mb/s and restart the network connection, I receive an IP as expected.
    To date, after having googled my brains out, I have not found any solution to this little dilemma. I have asked on a different forum a similar question but the few people there could not give any answers.  The only real answer I got was to swap out NICs (a somewhat useless suggestion as it is built-in). I hoped that posting here, perhaps someone with a similar NIC could offer any insight into this issue.  Failing that, could someone tell me if I should report this as a bug to some developer perhaps (Ethtools' dev?).
    I will provide any other information possible on-demand to any who may have insight. For now, I've posted as much as I could think of to help shed light on this.
    MS

    There are two Realtek modules, 8139cp and 8139too. See which one is active, kill it, and try the other.

  • Bug with SET_LOV_COLUMN_PROPERTY Built-In (or FORMS_SUCCESS). FRM-41364.

    Hi everyone,
    I have an in-house pll library which supports the translation of custom forms into multiple languages.
    By and large, this code works perfectly fine.
    One of the tasks of the code is to analyse a given custom-form, and create a list in a custom-table of all of the items, buttons, LOVs, windows etc in the form - i.e. all of the items that can-be/need-to-be translated, such that the user can then update/maintain the translations.
    When it comes to the LOV columns, there is no direct way (as far as I am aware) to tell how many columns are in an LOV. Additionally, there is no GET_LOV_COLUMN_PROPERTY. So, what the PLL does is LOOP from 1 .. 10 (making the assumption that no LOV will have more than 10 columns) and each time around the loop it calls the SET_LOV_COLUMN_PROPERTY(curr_lov_name, loop_index, TITLE, '');, which effectively does nothing, but then the code immediately makes a call to FORM_SUCCESS.
    If TRUE, then we know the SET_LOV_COLUMN_PROPERTY worked, which means there must have been a column numbered <loop_index> so we can insert a record into the translations table for that one, if FORM_SUCCESS is FALSE, then do nothing (other than loop around a few more times until we get to 10, then fall out of the loop). It's not ideal, but it works ... except - for one particular form, the code raises FRM-41364.
    Initially, out of habit, I enclosed the code in an anonymous block, but then I remembered that Built-In's don't actually raise exceptions when they fail.
    So I sprinkled in a load of debug messages (via AUTONOMOUS COMMIT) and indeed the call to SET_LOV_COLUMN_PROPERTY is the last call before the FRM-41264 error pops up on screen. Can anyone understand why this error show up on one form and not all the others? The LOVs seem identical (in terms of properties, etc, obviously the actual SELECTs are different). I even created a new LOV in the bad form, in case it was something corrupt, but I got the same problem.
    The FRM-41364 error is a level-99 error, so the setting of the :system.message_level shouldn't have any effect (you can only set from 0 - 25).
    There is one other possible clue to the mystery - when I first put in the debug messages, I put one in between the SET_LOV_COLUMN_PROPERTY call and the check of FORM_SUCCESS, which I subsequently removed because Oracle recommends against this (i.e. You should always call FORM_SUCCESS immediately after the Built-In you want to test). However, I did notice in the error log that not only did the "before" debug message appear, but also the "after" debug message. So it was as if the FORM_SUCCESS call was actually the one that raised the FRM-41364, which was most peculiar to me.
    I am using Forms Builder 10.12.0.2 on Windows XP, and I am compiling on an R12.1.3 EBS instance running on an 11.2.0.2.0 database.
    Here is the code, note - the exception section never gets called:
    FOR loop_index IN 1..10 LOOP
      debug ( 'Before Anonymous block');
      BEGIN
        debug ( 'Before set_lov_column_property');
        set_lov_column_property (curr_lov_name, loop_index, TITLE, '');
        IF FORM_SUCCESS THEN
          debug ( 'Add LOV column for translation');
          my_package.my_insert_translation_proc();
        ELSE
          debug ( 'FORMS_SUCCESS - FALSE');
        END IF;
        debug ( 'After FORM_SUCCESS test');
      EXCEPTION
        WHEN OTHERS THEN
          debug ( 'EXCEPTION');
      END;
      debug ( 'After block');
    END LOOP;
    debug ( 'After LOOP');Thanks in advance for any help or suggestions anyone can offer,
    Alan.
    Edited by: 958388 on 11-Sep-2012 07:59 (Typo in title)

    Hi Oleh,
    I was just returning to the thread to report that I'd found the issue (actually a colleague did) - and it is exactly what you said - the in-house documentation for the translations library says to add an ON-ERROR trigger to capture (and ignore) 41364, but whoever developed this form apparently forgot to perform this step.
    You still get the brownie points for the answer though =)
    Thanks for the help, my mind is more restful now because I was going nuts trying to find this!
    Alan.

  • Bug or Feature - Loading / Unloading times before acceptable dates

    Hi Experts,
    I am facing an issue during Scheduling of Freight Orders. I have maintained 1 hr for Loading and Unloading times in the Planning Profile and set the system up to consider Freight Unit Dates.
    The Freight Order has only 1 Freight Unit stage - so a fairly easy example.
    Now when I look at the Freight Unit Dates after the scheduling run, the unloading starts at 02/13 23:00 , so even before the acceptable start date.
    Therefore my question: Is it a bug or a feature? According to my understand this should not happen.
    Thanks,
    Thomas

    2072923 - Changing pickup/delivery date to outside Pickup/delivery window triggers execution block for first and last
    This note may help.

  • Time validation from validation.xml file

    i've inherited part of a project and need to be able to validate a user inputting time into a field, at present it's set for a 24 hr clock, but the mask as it is will let them input eg 25:45, because its checking each digit rather than is it less than 24
    entry from our validation.xml file:
    <field property="time" indexedListProperty="configBillingPeriodTable" depends="mask">
    <arg0 key="taWebLabel.Time"/>
    <var>
    <var-name>mask</var-name>
    <var-value>^[0-2][0-9]:[0-5][0-9]$</var-value>
    </var>
    </field>
    this stuff is new to me, so excuse the basic questions!! how can I set the first part of the mask to limit to 23, and where can I find info on what expressions I can use between the <var-value></var-value> tags
    thnx

    I believe it would be this:
    ^([0-1][0-9]|[2][0-3]):[0-5][0-9]$
    or if you don't want leading 0's for 0-9...
    ^([0-9]|[1][0-9]|[2][0-3]):[0-5][0-9]$

  • Built in Constraint Validation before DML

    I have generated Business Components from DB Tables and FK's. When I run the AM in testmode, I expected the Entity Constraints to be checked either upon item validation time or at DML time. But the framework tries to commit invalid data (e.g. child rows w/o matching parent rows) to the DB and displays the resulting Oracle Error as SQLException. Was I expecting wrong, or have Entity Constraints never been thought to be validated at runtime ? If the latter is true, is there any way to generate declarative validation logic for the EO's that reflect the Entity Constraints besides of the not null Check Constraints? I find the need to declare validation logic which matches information accessible for JDev not a task compliant with "productivity with choice".
    And, what is the Key Properties meaning in the Entity Constraint Editor - Properties dialogue ?
    I find it an advantage to test the constraints before performing DML, as does good old Designer generated Forms (no rolled back TX, more accurate user information possible).

    You can expose accessors for each end of an association. For example, say you have tables Emp and Dept. If you have an association between them (joining Emp.DeptId to Dept.Id for example) you can expose the accessors. Then, in the EmpImpl.java file you could use that accessor to get at the associated record in the Dept table. You could then check to see if there is an associated record by calling the getDept() method call in the EmpImpl.java file. I'm not sure how accurate this is, I'd have to look into it further, but it doesn't matter for me because I am commiting on every action so the cache should always be consistent with the DB (except during this transaction obviously)...
    If you need more information on using this method I suggest opening a new thread specifically about it.
    I used to be of the opinion that you should check everything at the application level to save trips to the Database and cut down on DB load. However, there are things that a database does much better than application code, such as catching constraint violations. As such, I do basic validations and then send it to the DB if it passes. The only problem I have with this is that by default JDevloper throws really ugly database error messages which the average user will not understand. To bypass this I found that you can override the default error messages and create a lookup for error messages where you can catch the DB errors and provide user-friendly versions. I have forgotten the steps involved, but it uses the DBTransactionFactory and other classes... I will look for the old thread I got it from later if you like...

  • Workspace bug - all messed up every time Premiere launches

    Hello. Ever since the second to last update, my Premiere workspace keeps getting messed up each time I run the program.
    I have attached a screenshot here. All the panels are somehow squeezed to the left, the video track part of the timeline is collapsed as well. I have to manually drag everything back to the way it was every time I start the app.
    Tried resetting application prefereces (holding shift-alt-ctrl while starting the app), that reset the workspace, but it was messed up again the next time I launched. Tried saving a new workspace or loading a default one. No luck.
    This happens randomly. Sometimes when I quit Premiere and launch it again straight away, the workspace is preserved. Other times, when I don't use the app for a longer period of time (few hours) - it happenes again on start.
    I can't seem to figure out what the problem here is. please help?
    HP Z820, Windows 8.1, Adobe CC2014.2 release, HP Quadro K5000.

    Thanks for your reply.
    None of the things you mentioned solve the issue, I still get a squeezed workspace, even if I create a new project.
    But since you say this bug is known, I guess there is nothing to do but wait for it to get fixed by Adobe.

Maybe you are looking for

  • Issue with Exporting to PDF appears to be saving Automatically

    Currently under SAP Business One Version 2007A SP:01 and PL:09 On Exporting any report or document using the PDF  button on the Toolbar Open's up PDF  viewer showing the document, but also appears to automatically save a copy into the path of the "Pi

  • Data From DataBase

    Hello I have a Data Block i.e. DEMAND_ORDER_DET and Three Tubular Items Names are Part_Id, Total_in_hand, Reorder_level. I want when Form Load Then All data Comes in these Items, Like Part_id from database into :DEMAND_ORDER_DET.Part_id Total_In_hand

  • Best Quality for .avi movies in iMovie HD?

    Hello: I recently had a number of old 8mm and Super8 movies converted to .avi files. The quality is pretty good and I want to create some DVD movies and I was want some suggestions on the best quality settings when exporting either to iDVD or Toast.

  • Problem in create  a oPurchaseDeliveryNotes

    Hi, I am trying to create a oPurchaseDeliveryNotes  using DI API. When I create Item oPurchaseDeliveryNotes have problems. This is the code:                     SAPbobsCOM.Documents objDoc;                     objDoc = (SAPbobsCOM.Documents) (Company

  • HT1438 I would like to use my Ipad mini to connect to a project can this be done?

    I would like to use my ipad mini to connect to a projector can this be done?