Change in one line item should Populate for all line items
Hi ,
We have added one custom field Prefereed Vendor at line item level.
We have requirement that if Prefereed Vendor at one line item level is changed,
then it should populate for all the line items.
Can any one tell me how it can be implemented?
Thanks in Advance.
Snehal
Hello,
I assume you are referring to SC. In standard SRM Preferred Vendor is a partner to an Item. But based on your post, have you added the Preferred vendor as a CUF field?
Anyway we can achive your requirement in DOC_CHANGE_BADI. This BADI has importing parameter IT_ITEM and exporting as ET_ITEM.
1. Get the SC from PD buffer using BBP_PD_SC_GETdETAIL into LT_ITEM
2. Compare the preferred vendor for every item in IT_ITEM with corresponding item in PD buffer
3. If for some item, the preferred vendor for IT_ITEM is diferrent from that of LT_ITEM --> means we found the item for which preferred vendor was chaged
4. Now populate ET_ITEM based on IT_ITEM along with copying the preferred vendor from changed item to all items.
Rgds,
Prasanna
Similar Messages
-
ME21N - new field added and same value posted to it for all line items
hi all
i have added new field under item level in me21n screen.
data for new filed fetched from tables with values entered in header level material number.
For one record, it is ok
but for multiple records, same value is fetched for all line items
i have written coding in screen exit for 0111
and function exits EXIT_SAPMM06E_016 and EXIT_SAPMM06E_018
how to solve
pl help
regards
senthilMODULE STATUS_0111 OUTPUT.
SET PF-STATUS 'xxxxxxxx'.
SET TITLEBAR 'xxx'.
if sy-tcode eq 'ME23N' or sy-tcode eq 'ME23'.
LOOP at SCREEN.
if screen-group1 ne 'PCS'.
screen-input = 0.
MODIFY SCREEN.
endif.
ENDLOOP.
ENDIF.
TYPES : BEGIN OF ty_cabn1,
atnam TYPE cabn-atnam,
end of ty_cabn1.
DATA : itab_cabn1 TYPE STANDARD TABLE OF ty_cabn1 INITIAL SIZE 0,
wa_cabn1 TYPE ty_cabn1.
TYPES : BEGIN OF ty_cawn1,
atinn TYPE cawn-atinn,
atzhl TYPE cawn-atzhl,
atwrt TYPE cawn-atwrt,
end of ty_cawn1.
DATA : itab_cawn1 TYPE STANDARD TABLE OF ty_cawn1 INITIAL SIZE 0,
wa_cawn1 TYPE ty_cawn1.
TYPES : BEGIN OF ty_cawnt1,
pcs TYPE cawnt-atwtb,
atinn TYPE cawnt-atinn,
atzhl TYPE cawnt-atzhl,
atwtb TYPE cawnt-atwtb,
end of ty_cawnt1.
DATA : itab_cawnt1 TYPE TABLE OF ty_cawnt1,
wa_cawnt1 TYPE ty_cawnt1.
TYPES : BEGIN OF ty_pcs1,
pcs TYPE cawnt-atwtb,
atwrt TYPE cawn-atwrt,
atwtb TYPE cawnt-atwtb,
end of ty_pcs1.
DATA : itab_pcs3 TYPE TABLE OF ty_pcs1,
itab_pcs4 TYPE TABLE OF ty_pcs1,
wa_pcs1 TYPE ty_pcs1.
TYPES : BEGIN OF ty_pcsn,
matnr TYPE ausp-objek,
ebelp TYPE dynpread-stepl,
atwrt TYPE cawn-atwrt,
atwtb TYPE cawnt-atwtb,
END OF ty_pcsn.
DATA : itab_pcsn TYPE TABLE OF ty_pcsn,
wa_pcsn TYPE ty_pcsn.
TYPES : BEGIN OF ty_ausp1,
objek TYPE ausp-objek,
atinn TYPE ausp-atinn,
atwrt TYPE ausp-atwrt,
END OF ty_ausp1.
DATA : itab_ausp1 TYPE STANDARD TABLE OF ty_ausp1 INITIAL SIZE 0,
wa_ausp1 TYPE ty_ausp1.
DATA : param_name1(35) TYPE c.
DATA: progname1 TYPE sy-repid,
dynnum1 TYPE sy-dynnr,
dynpro_values1 TYPE TABLE OF dynpread,
dynpro_values2 TYPE TABLE OF dynpread,
field_value1 LIKE LINE OF dynpro_values1,
ematn1 TYPE mara-matnr.
if sy-tcode ne 'ME23N' and sy-tcode ne 'ME23'. "psk
clear : itab_cabn1,itab_cawn1,itab_cawnt1,itab_pcs3,itab_pcs4,itab_pcsn,itab_ausp1.
clear : wa_cawn1,wa_cawnt1,wa_pcs1,wa_ausp1.
if sy-uname eq 'IBM_ABAP'.
param_name1 = '000000001'.
else.
param_name1 = '000000013'.
endif.
SELECT atnam
FROM cabn
INTO CORRESPONDING FIELDS OF TABLE itab_cabn1
WHERE atinn = param_name1.
select *
FROM cawn
into CORRESPONDING FIELDS OF TABLE itab_cawn1
WHERE atinn = param_name1.
if itab_cawn1[] is NOT INITIAL.
SELECT atinn atzhl atwtb
FROM cawnt
INTo CORRESPONDING FIELDS OF TABLE itab_cawnt1
FOR ALL ENTRIES IN itab_cawn1
WHERE atinn = itab_cawn1-atinn
AND atzhl = itab_cawn1-atzhl.
endif.
if itab_cawnt1[] is NOT INITIAL.
sort itab_cawnt1 by atinn atzhl.
loop at itab_cawnt1 INTO wa_cawnt1.
READ TABLE itab_cawn1 INTO wa_cawn1 with key atinn = wa_cawnt1-atinn
atzhl = wa_cawnt1-atzhl BINARY SEARCH.
if sy-subrc eq 0.
CONCATENATE wa_cawn-atwrt '->' wa_cawnt-atwtb INTO wa_cawnt-pcs.
MODIFY itab_cawnt FROM wa_cawnt TRANSPORTING pcs.
wa_pcs-pcs = wa_cawnt-pcs.
wa_pcs1-atwrt = wa_cawn1-atwrt.
wa_pcs1-atwtb = wa_cawnt1-atwtb.
append wa_pcs1 to itab_pcs3.
ENDIF.
CLEAR : wa_cawnt1,wa_cawn1, wa_pcs1.
ENDLOOP.
ENDIF.
CLEAR: dynpro_values1, field_value1.
dynpro_values-FIELDNAME = 'MEPO1211-EMATN'.
APPEND dynpro_values.
field_value1-fieldname = 'MEPO1211-ematn'.
APPEND field_value1 TO dynpro_values1.
progname1 = 'SAPLMEGUI'.
dynnum1 = '1211'.
CALL FUNCTION 'DYNP_VALUES_READ'
EXPORTING
DYNAME = progname1
DYNUMB = dynnum1
TRANSLATE_TO_UPPER = ' '
REQUEST = 'A'
PERFORM_CONVERSION_EXITS = ' '
PERFORM_INPUT_CONVERSION = ' '
DETERMINE_LOOP_INDEX = ' '
START_SEARCH_IN_CURRENT_SCREEN = ' '
START_SEARCH_IN_MAIN_SCREEN = ' '
START_SEARCH_IN_STACKED_SCREEN = ' '
START_SEARCH_ON_SCR_STACKPOS = ' '
SEARCH_OWN_SUBSCREENS_FIRST = ' '
SEARCHPATH_OF_SUBSCREEN_AREAS = ' '
TABLES
DYNPFIELDS = dynpro_values1
EXCEPTIONS
INVALID_ABAPWORKAREA = 1
INVALID_DYNPROFIELD = 2
INVALID_DYNPRONAME = 3
INVALID_DYNPRONUMMER = 4
INVALID_REQUEST = 5
NO_FIELDDESCRIPTION = 6
INVALID_PARAMETER = 7
UNDEFIND_ERROR = 8
DOUBLE_CONVERSION = 9
STEPL_NOT_FOUND = 10
OTHERS = 11
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
READ TABLE dynpro_values1 INTO field_value1 with KEY fieldname = 'MEPO1211-EMATN'.
LOOP at dynpro_values1 INTO field_value1 WHERE fieldname = 'MEPO1211-EMATN'.
clear ematn1.
if sy-subrc eq 0.
ematn1 = field_value1-fieldvalue.
endif.
if ematn1 is not INITIAL.
clear : wa_cawn1,wa_cawnt1,wa_pcs1,wa_ausp1.
CALL FUNCTION 'CONVERSION_EXIT_ALPHA_INPUT'
EXPORTING
INPUT = ematn1
IMPORTING
OUTPUT = ematn1.
select *
FROM ausp
INTO CORRESPONDING FIELDS OF TABLE itab_ausp1
WHERE objek = ematn1
and atinn = param_name1.
CLEAR itab_pcs4.
if itab_ausp1[] is not INITIAL.
sort itab_ausp1 by atinn atwrt.
sort itab_cawn1 by atinn.
READ TABLE itab_ausp1 INTO wa_ausp1 INDEX 1.
loop at itab_cawn1 INTO wa_cawn1 WHERE atinn = wa_ausp1-atinn AND atwrt = wa_ausp1-atwrt.
READ TABLE itab_cawnt1 INTO wa_cawnt1 WITH KEY atinn = wa_cawn1-atinn
atzhl = wa_cawn1-atzhl.
if sy-subrc eq 0.
wa_pcs1-atwrt = wa_cawn1-atwrt.
wa_pcs1-atwtb = wa_cawnt1-atwtb.
append wa_pcs1 to itab_pcs4.
wa_pcsn-matnr = wa_ausp1-objek.
wa_pcsn-ebelp = field_value1-stepl.
wa_pcsn-atwrt = wa_cawn1-atwrt.
wa_pcsn-atwtb = wa_cawnt1-atwtb.
APPEND wa_pcsn to itab_pcsn.
ENDIF.
clear : wa_ausp1,wa_cawn1,wa_cawnt1.
ENDLOOP.
ENDIF.
clear wa_pcs1.
read TABLE itab_pcs4 into wa_pcs1 index 1.
if sy-subrc eq 0.
EKPO_CI-ZPCS = wa_pcs1-atwrt.
endif.
ENDIF.
ENDLOOP.
CLEAR: field_value1.
LOOP at dynpro_values1 INTO field_value1 WHERE fieldname = 'MEPO1211-EMATN'.
clear wa_pcsn.
if field_value1-fieldvalue is not INITIAL.
read TABLE itab_pcsn INTO wa_pcsn with key matnr = field_value1-fieldvalue
ebelp = field_value1-stepl.
if sy-subrc eq 0.
clear EKPO_CI-ZPCS.
*EKPO_CI-ZPCS = wa_pcs1-atwrt.
EKPO_CI-ZPCS = wa_pcsn-atwrt.
endif.
endif.
ENDLOOP.
CLEAR: field_value1, dynpro_values1.
progname1 = 'SAPLXM06'.
dynnum1 = '0111'.
field_value1-fieldname = 'EKPO_CI-ZPCS'.
APPEND field_value1 TO dynpro_values1.
if ematn1 is not INITIAL.
clear wa_pcs1.
read TABLE itab_pcs4 into wa_pcs1 index 1.
if sy-subrc eq 0.
EKPO_CI-ZPCS = wa_pcs1-atwrt.
endif.
ENDIF.
endif.
ENDMODULE. " STATUS_0111 OUTPUT
Function exits:
^^^^^^^^^^^^^^^^^
EXIT_SAPMM06E_016
^^^^^^^^^^^^^^^^^
INCLUDE ZXM06U41 .
DATA XFISTL LIKE EKPO-FISTL.
TABLES: ADRC, T001W.
DATA: PLANT LIKE T001W-WERKS.
SELECT SINGLE * FROM T001W WHERE WERKS = I_EKPO-WERKS.
SELECT SINGLE * FROM ADRC WHERE ADDRNUMBER = T001W-ADRNR.
XFISTL = ADRC-SORT2.
SET PARAMETER ID 'FIS' FIELD XFISTL.
* Added For PCS 12.11.2010
DATA : fs_ekpo type EKPO_CI.
if sy-tcode = 'ME22N' or sy-tcode = 'ME23N'.
* if tekpo-zpcs is INITIAL.
* message e000(zmm) with 'PCS Type should be chosen'.
* endif.
loop at tekpo.
if ( tekpo-ebeln eq i_ekpo-ebeln and tekpo-ebelp eq i_ekpo-ebelp ).
ekpo_ci-zpcs = tekpo-zpcs.
endif.
ENDLOOP.
endif.
^^^^^^^^^^^^^^^^^
EXIT_SAPMM06E_018
^^^^^^^^^^^^^^^^^
INCLUDE ZXM06U40 .
E_CI_EKPO-ZPCS = EKPO_CI-ZPCS.
E_CI_UPDATE = 'X'. -
How can i show item schedule line details in Tableview for each line item
Hai all,
I need to display schedule line details in Tableview for each line item.for example in each row i need to put one column along with button , if i click on this table that row should be expand vertically and must show all schedule line details in that.if i click my button again the visible expanded row should disappear...
if anybody works on this previously plz send some sample code...
leoiz....To modify rows the best way is with the Iterator (do a search in the weblogs for "Iterator")
However for what you want to do I've only seen this really work successfully with a standard HTML table not using the tableView. -
Any Way to Change Thickness of Connector Lines for all lines of a Chart?
Post Author: ScottL
CA Forum: Charts and Graphs
Hi All,
I am trying to change the thickness of a Chart's Connector Lines for all lines of a chart and cannot find a way to accomplish this. I can go into Report Preview and individually change the thickness one at a time, but what if I do not know how many lines I will have (as in a Line Chart) ? I can't find a way to do this through Crystal Reports XI.
Many thanks in advance!
ScottI think it's even easier to just match frame the "source file"... put your playhead on the clip you want to speed change in your sequence. Then type optioncmdf. Perform the speed change in the Viewer, then simply cut it in... Might help to put it up above the older, use the double arrow selection tool facing right to move the clips past this change later... pull the upper track speed changed clip down over the old, and viola.
Gotta say though, it's a lot easier to perform the speed change in the Viewer, and edit it all in as you go rather than doing it after you've put the clip in a sequence. (not always possible to determine what the speed change should be maybe, but sure easier.... FCP 7 handles this problem a lot better for sure, and worth the upgrade price if your machine is compatible.
Jerry -
Can it not possible that i can retrive it for all line items in a single qu
I have to make report for my application in which I am facing a following problem:
In the application there are multiple suppliers and each supplier having multiple line items and each item having multipale events. each evant having three status GREEN,RED and BLUE.
When a user select 'all suppliers' to show the the status time span for a supplier (i.e. for a supplier how many parts and upto how much time parts are in blue, red and green status)
to show the cumulative status time span I have to find out a event for each line item which is having nearest lower entry time from the lower part of the given time span.for this i have write following query
SELECT * FROM parts_events
WHERE vendorid = ? AND partid = ?
AND visible = 'visible' AND active = 1
AND entrytime = (SELECT MAX(entrytime) as
entrytime from parts_events
WHERE vendorid = ?
AND partid = ?
AND entrytime < ?
AND visible = 'visible'
AND active = 1)
the problem is that i have to fire this query for each line item, can it not possible that i can retrive it for all line items in a single query?maybe if you can post some sample data and output will help us analyze more youre requirement.
-
What is Tcode for single delivery for all line items in PO
Hi all,
Sorry if it is a simple question, But I am from SD module. What is Tcode to create a single delivery documents for all line items in PO. I have 3 line items with Different materials having diffent quantities and there are different delivery dates and different delivery schedule dates. I need to create single delivery. Could you please tell me how to do it? What is the Tcode?
Thanks
AnilHi,
Inbound delivery T.code :VL31N,
Regards,
JS -
Tcode to create single delivery document for all line items in PO
Hi all,
Sorry if it is a simple question, But I am from SD module. What is Tcode to create a single delivery documents for all line items in PO. I have 3 line items with Different materials having diffent quantities and there are different delivery dates and different delivery schedule dates. I need to create single delivery. Could you please tell me how to do it? What is the Tcode?
Thanks
AnilHi,
Inbound delivery T.code VL31N.
Regards,
JS -
What is Tcode to create a single delivery documents for all line itemsinPO?
Hi all,
Sorry if it is a simple question, But I am from SD module. What is Tcode to create a single delivery documents for all line items in PO. I have 3 line items with Different materials having diffent quantities and there are different delivery dates and different delivery schedule dates. I need to create single delivery. Could you please tell me how to do it? What is the Tcode?
Thanks
AnilHi Anil
For your 1st question , if the delivery date is same but he material and quantity are different also then both can be delivered . So you can combine those two materials into 1 delivery . what you said is true
For your 2nd question , you said you have two line items in PO , but if you want combine them into 1 delivery document , then first of all as they are two different materials you cant combine , but if you have a 3 PO's for the one material only then you can combine into one delivery by using VL10A
Regards
Srinath -
A scaled condition for all po-items
Hello Gurus,
we want to have a scaled condition for all po-items.
Example: we have 1 PO with 2 PO-Items (same material). Each Po-Item has 1 piece. The condition scaled fort wo pieces.
Any Ideas?
Thank you!
PeterIts better to create two seperate PO then
or
Club the qty and create one PO with one line item only. -
Allow only one set of parameter values for all worksheets
I would like to " Allow only one set of parameter values for all worksheets ", but prompt before executing the worksheet. This function is a great time saver, but the users on occasion would like to change at the least one of the parameters. Is this possible? What setting do I use? I've tried various combinations of the " After opening a workbook: " on the options page. " Run query automatically", " Don't run query (leave sheet empty) ", and " Ask for comformation ". I would have thought that "Ask for comformation " was the trick, but no. I'm considering putting a do nothing parameter that has the setting of " Allow different parameter values for each worksheet. " so that it will keep all the others, default this one, but prompt for a possible change.
Any thoughts...
Thanks,
JamieHi Jamie
Even though you have the same parameter for all worksheets a user can still choose what to use on a worksheet. Its just that if they click to another worksheet then that parameter will be applied.
Which version of Discoverer are you using?
Best wishes
Michael -
Query For Finding Yearly Opening and Closing Balance for All the Items
Hi Experts,
I am working on Query Based Report for finding the Yearly Opening and Closing Stock for all the Items
i will give yearwise selection and I want opening and closing stock in between that years
Warm Regards,
Sandip Kokate
Edited by: Sandipk on May 20, 2011 1:58 PMHi,
Declare @SDate DateTime
Declare @EDate DateTime
Declare @Whse nvarchar(10)
Set @SDate= (SELECT min(F_RefDate) FROM OFPR T1 where T1.[Name] ='[1%]' )
Set @EDate= (SELECT max(T_RefDate) FROM OFPR T1 where T1.[Name] ='[%1]' )
Set @Whse=(Select Max(s2.Warehouse) from OINM S2 Where S2.Warehouse = '[%2]')
BEGIN
Select @Whse as 'Warehouse', a.Itemcode, max(a.Dscription) as ItemName,
sum(a.OpeningBalance) as OpeningBalance, sum(a.INq) as 'IN', sum(a.OUT) as OUT,
((sum(a.OpeningBalance) + sum(a.INq)) - Sum(a.OUT)) as Closing ,
(Select i.InvntryUom from OITM i where i.ItemCode=a.Itemcode) as UOM
from( Select N1.Warehouse, N1.Itemcode, N1.Dscription, (sum(N1.inqty)-sum(n1.outqty))
as OpeningBalance, 0 as INq, 0 as OUT From dbo.OINM N1
Where N1.DocDate < @SDate and N1.Warehouse = @Whse Group By N1.Warehouse,N1.ItemCode,
N1.Dscription Union All select N1.Warehouse, N1.Itemcode, N1.Dscription, 0 as OpeningBalance,
sum(N1.inqty) , 0 as OUT From dbo.OINM N1 Where N1.DocDate >= @SDate and N1.DocDate <= @EDate
and N1.Inqty >0 and N1.Warehouse = @Whse Group By N1.Warehouse,N1.ItemCode,N1.Dscription
Union All select N1.Warehouse, N1.Itemcode, N1.Dscription, 0 as OpeningBalance, 0 , sum(N1.outqty) as OUT
From dbo.OINM N1 Where N1.DocDate >= @SDate and N1.DocDate <=@EDate and N1.OutQty > 0
and N1.Warehouse = @Whse Group By N1.Warehouse,N1.ItemCode,N1.Dscription) a, dbo.OITM I1
where a.ItemCode=I1.ItemCode
Group By a.Itemcode Having sum(a.OpeningBalance) + sum(a.INq) + sum(a.OUT) > 0 Order By a.Itemcode
END
I hope this will work for you.
In above query you can also user OFPR.Code, OFPR, Category OFPR.Indicator instead of OFPR.Name.
Regards
Vaibhav Anharwadkar
Edited by: Vaibhav Ancharwadkar on May 24, 2011 9:23 AM -
Display of icons in the items of dropdownListBox for a single item
Dear BSP Gurus,
Do you know if it is possible to display icons in the items of dropdownListBox for every single item?
To assign and display icon to buttons I do:
lv_image->id = 'UserSelectionCancel2'.
lv_image->src = '/sap/public/bc/icons/s_B_OKYE.gif'.
lv_image->tooltip = ''.
clear lv_image_string.
lv_image_string = lv_image->IF_BSP_BEE~RENDER_TO_STRING( page_context ).
%>
<xhtmlb:toolbarButton id = "<%= ywfx1_b_bcontinueWF %>"
design = "STANDARD"
text = "<%= lv_image_string %> <%= otr(YWF11/ContWF) %>"
But I could not managed to do it for the " <htmlb:dropdownListBox ...".
We have application developed in ABAP WebDynpro and there it is possible, so I want to do exactly the same with BSP.
Any idea?
Thanks in advance,
ValentinHallo Alexandre,
But what if I use table for defining the items?
Like:
htmlb:dropdownListBox id = "DropDownCommands"
table = "<%= application->mt_commands %>"
nameOfKeyColumn = "VAL_COMMAND".."
Where "application->mt_commands" is table of strings?
Would it be some how possible?
Regards,
Valentin -
How to create a single 'not null ' validation for all the items in a page ?
Hi everyone ,
how to create a single 'not null ' validation for all the items in a page ? I have many textfields . Instead of creating 'not null' validation for each item , I would like to create a a single validation control that will serve the purpose
Thanks & Regards
UmerNice1 wrote:
bob , as u said I have done the following :
1) under create button , there are 9 items and for each item I have set Required to 'Yes'
2) under delete button , there is 1 item and have set Required to 'Yes' for the item
3) defined page validation for 9 items under 'create ' button and have set it to fire when 'create ' button clicked
4) defined page validation for 1 item under 'delete ' button and have set it to fire when 'delete ' button clicked
now , when I click 'create' button it even shows for the item under 'Delete ' button that it is a required itemSorry, I didn't see this note. The required template won't work, there is no way to attach it to the button.
The best solution is as the reply a couple replies up
Create 2 page type validations as a PL/SQL with code
1st validation
:P1_ITEM1 IS NOT NULL and :P1_ITEM2 IS NOT NULL ...... and :P1_ITEM9 IS NOT NULL include all 9 items
Set the When Button Pressed to the CREATE button
2nd validation
:P1_ITEM10 IS NOT NULL
Set the When Button Pressed to the DELETE buttonI think that's going to be the easiest way to do it.
Edited by: Bob37 on Apr 27, 2012 12:02 PM -
No purchase order item was generated for shipment cost item
Hi Gurus,
When I am creating with reference to shipment no & shipment cost type, When I save the shipment cost, See the logs at the time saving.
The logs are showing in red :
No purchase order item was generated for shipment cost item.
Message no. VY633
Please enter a valid partner role.
Message no. ME351
May I know the reason for showing red logs at the time of saving. (When I check logs, it is showing red colors).
Please advice if I miss any thing.
Regards
RakeshHi Rakesh,
Your customising is incomplete. Notes 506605 & 940532 will help you on this.
regards, david -
1 line item in invoice for Multiple line items of SO
Hi SD Gurus,
My client requirement is multiple line items of the sales order should reflect as a single line item in the invoice ..?
For ex: I am using Service material type Dien & material created under different material groups.
My Sales order looks somthing like below with material no & amount:
10 Testing charges 10$ material group xx1
20 Baking charges 20$ material group xx2
30 Scan/Taping 20$ matierial group xx1
Now in the invoice its should reflect only with 1 line item with the whole amount 50$.
Kinldy let me know how this requriement can be fullfilled.
Thanks,
RahulDear Rahul
I think you can apply Rate Routing for this.
A rate routing is a routing for repetitive manufacturing. It enables you to easily reproduce the lean production process.
In the rate routing, the production rate per operation is defined (production time according to a base quantity). Set-up time is not usually defined, since no changes to setup are planned.
However, you can also use standard routings. A standard routing represents the various steps of production (such as setup, processing, teardown and so on), operation by operation, if necessary with suboperations.
A rate routing does, however, offer all the same functions as a standard routing.
<b>Structure</b>
If you use the same standard value key for all the work centers on the line, the system copies the descriptions of the standard values to the routing as the column headings of the operation overview.
If you use different standard value keys for the work centers, the system copies the descriptions into the routing that is entered in the control data for the routing in Customizing.
To create a Rate Routing, follow the steps as under:-
1) Starting from the main Line Design menu, choose Rate routing --> Create.
The system displays the initial screen for rate routings.
2) Enter the plant, the material and in the field Group, the group to which you want to assign the rate routing.
3) Choose Enter.
The system displays the screen Header details.
4) Enter the following data:
=> the routing description
=> the plant
=> the usage of the rate routing, i.e.production
=> the status, i.e. released
=> the unit of measure of the materials to be produced
5) Save your rate routing.
<b>Result</b>
You have created the rate routing. Continue creating the main production line and if necessary, feeder lines.
You can also take the help of your PP guy for this.
Thanks
G. Lakshmipathi
Maybe you are looking for
-
I have made a list of I.D.'s and passwords for various sites I access, personally. I want to put them in alphabetical order. The doc. was generated thru the use of "Pages." What is the easiest way to reorganize my doc so it is in alphabetical ord
-
Two keys 5 and 6 are jammed on my laptop. Any solution?
-
Assessments - company code as sender/receiver field
Hello experts, We're currently running assessments to move costs between cost centers in SPL (GA11/13/15) and are deactivating SPL and moving to the CO module (KSU1/3/5). In SPL, company code can be utilized as a sender/receiver field: you can defin
-
I need to place my profiles on another drive insted of c:desktop/
'''I need to place my profiles on another drive insted of c:desktop/. so if windows crashes i just start when every thing is installed i just redrict firefox to pickup my profiles, just as was in netscape brgds fernandes63'''
-
Can you use Paypal to pay in iTunes?
Hi As the title.....can i use Paypal to pay? Have searched and some people say yes they do, others say no. I live in the UK if that makes a difference! Cheers