Changing the limits on 3D Dial Guage

Hi,
I am trying to limit the Red,Green & Yellow arc lengths on the 3d Dial Guage. For E.g. i want to show 0-30 as red, 30-50 as yellow & the rest as green. I am able to rotate the arcs using "transform" property of the respective arcs.
I found few threads on sdn which says it can be done using SVG Object properties instead of using the "transform" property.
Can you pls. tell me exactly how using the SVG Object properties we can limit the low & high values of each of the arc's?
Regards,
Sushma.

Hi Sushma,
I had a similar requirement long back and I got the solution by playing with it. Please try the below.
Define Object Properties (of type Number):
   HighLimit
   LowLimit
   MaxRange
   MinRange
In your case, set HighLimit to 50 and LowLimit to 30 . Set MinRange and MaxRange as per your requirements (for example: 0 and 100)
Set Animation Links as follows (click Assign Link to set this value): 
YellowArc: d
"M107.59 266.52  A 124,124 0 "  & if( ((HighLimit - MinRange) / (MaxRange - MinRange) ) > (180.0/320.0) ,1,0) & " 1 " & (150 + 124 * cos(pi * (110 + ((HighLimit - MinRange) / (MaxRange - MinRange) ) * 320) / 180)) & " " & (150 + 124 * sin(pi * (110 + ((HighLimit - MinRange) / (MaxRange - MinRange) ) * 320) / 180))
RedArc: d
"M107.59 266.52  A 124,124 0 "  & if( ((LowLimit - MinRange) / (MaxRange - MinRange) ) > (180.0/320.0) ,1,0) & " 1 " & (150 + 124 * cos(pi * (110 + ((LowLimit - MinRange) / (MaxRange - MinRange) ) * 320) / 180)) & " " & (150 + 124 * sin(pi * (110 + ((LowLimit - MinRange) / (MaxRange - MinRange) ) * 320) / 180))
Thanks,
John

Similar Messages

  • How to change the limitation of Table name's length?

    The length of table's name or field's name is limited to 30 characters.
    Can I change it? If I want to create a long name table,then how can I do?
    Thanks in advance!

    This is a duplicate of another question
    How to change Table name's length?
    The short answer is no, you cannot.
    Justin
    Distributed Database Consulting, Inc.
    http://www.ddbcinc.com/askDDBC

  • How to change the limitations of columns?

    Here's a screenshot of what I mean:
    http://img408.imageshack.us/my.php?image=sarake0al.jpg
    This is an album column. The album's name is "The Cream of Female Vocal Trance". iTunes cuts of the name after 30 marks.
    Is it possible to change this, so iTunes wouldn't cut these lines after 30 marks?

    I have iTunes 5.0.1.4
    I tried to manually type the album name and now it shows it correctly.
    On the other program (Foobar) the names are shown correctly, over 30 marks. When I changed to iTunes it limits the number of marks in every column to 30. So could the problem be in the ID3 version or somewhere?
    I won't start to change thousands of songs informations, if they are shown correctly on another program

  • Color range on 3D dial guage

    Hi,
    I am using 3D Dial gauge. I am trying to set the limits for red, yellow and green arcs.
    My requirement is to set the arcs as  0 to 85 : Red, 85 to 95 :Yellow, 95 to 100: Green with the Min range and Max range as 0-100.
    In the SVG Element properties, i can see the red arc , green arc and yellow arc but how to limit the range is not clear to me.
    Any idea will be a great help
    Thanks
    Shipra
    M-9886452721

    Hi Shipra,
    I think this thread will help you out.
    Re: Changing the limits on 3D Dial Guage
    Also, any changes you wish to make in your SVG, you can use Inkscape. Its a free and readily available tool and easy to understand and use.
    Check out these links too:
    Re: SVG PIE Chart - Limits
    Re: Half Gauge SVG - Change Coloured arcs
    Re: Limits on 3D dial gauge
    All the best.
    Regards,
    Gita K C.

  • How to change the display limits of a dynamic table?

    Hi folks,
    I'm using DW CS4 and PHP. I've got a php page with a dynamic table and repeating region that I built for my client. This table lists our entire active member list. Initially I built the dynamic table to show only 50 records at a time because 300+ records made an overly long page. Now my client wants all the records on a single page, because he doesn't like clicking through the recordset paging of First - Next - Previous - Last list to find who he is looking for. I tried changing the Repeating Region behavior to All Records (rather than 50) but it still displays only 50. I'm sure this is because initially when I set up the dynamic table, I limited it to 50 there. Is there an easy way to change the dynamic table from 50 to All Records, without rebuilding the entire page? I've looked in several places and can't find a way to edit this. Thanks for your help,
    Gail

    Gunter,
    Thanks for your continued help on this forum. You have made people's
    work a lot easier and stuck with them through some thorny issues.
    If I may redirect you to an issue I had a few months back - the initial
    posting was here at:
    http://forums.adobe.com/thread/767154?tstart=300
    I couldn't turn the answers I received into a workable solution. Would
    you be willing to take a look at this?
    Thanks again for your help,
    Gail

  • I have limited space on my windows drive i need to change the Cache Directory for firefox as due to limited space im unable to do so .. can some1 help me plz

    I am using windows xp professional and have firefox 3.6.8 i have very limited space on my partition the one with windows. I have my program files on another drive still only 20 mb left on my windows partition .. I'm downloading files using firefox but i get error as due to limited space the download does not get completed ... now i want firefox to use some other drive as a temp or cache folder ... how would i change its settings ... My windows temp folder is also on another drive rather then c drive ....
    I want to change the whole from
    D:\Documents and Settings\Kashif\Application Data\Mozilla\Firefox\Profiles\
    to
    C:\Documents and Settings\Kashif\Application Data\Mozilla\Firefox\Profiles\
    is there a way

    Solution
    go into
    about:config
    create new string - browser.cache.disk.parent_directory
    and then enter your new cache location i.e. D:\CACHE

  • How do I change the background pic thats behind my speed dial thumbnails

    i put a pic in the browser window behind my speed dial thumbnails and i cannot remember how to change it.

    Figured it out - When looking at your speed dial screen, do a right click, off to the side of a dialer, and choose '''''edit group''''', then select '''''additional style options''''', from there you can select an image background or colour.

  • To change the approval limit for Extended attribute PO Value limits

    Hi,
    We are on SRM 4.0, in PPOMA_BBP for a local purchasing organisation we want to change the approval limit let us say from 100 to 50 but the system is presenting this field as non editable( In stabdard values sub screen)
    In Extended attribute tab in organisation structure after selecting the PO Value limits in SRM 4.0 we see two sub screens
    a) Standard values
    b) Local values
    We want to change the approval limit in standard values sub screen from 1000 to 500, which system is presenting as noneditable.
    Regrds
    Vivek

    Hi
    Refer these links.
    http://help.sap.com/saphelp_srm50/helpdata/en/5a/af5efc85d011d2b42d006094b92d37/frameset.htm
    http://help.sap.com/saphelp_srm50/helpdata/en/8b/4fa9585db211d2b404006094b92d37/content.htm
    http://help.sap.com/saphelp_srm50/helpdata/en/fa/fa7d3cb7f58910e10000000a114084/frameset.htm
    http://help.sap.com/saphelp_srm50/helpdata/en/7f/0fea380bfe6161e10000000a11402f/frameset.htm
    Incase it does not helps, pls let me know.
    Regards
    - Atul

  • Why is the number "1" when setting up the dial fat thickness did not change the font? Is it possible to adjust the font in the thick klavioture typing?

    Why is the number "1" when setting up the dial fat thickness did not change the font? Is it possible to adjust the font in the thick klavioture typing?

    paulcb wrote:
    Using the Bold Text Accessibility option does make the keypad numbers a little bolder.
    Yep - I was only looking at Text Size.
    But still, not sure what the deal is. The "1" is just as readable as any other number on the keyboard regardless.

  • Dial plan: Can we change the redirect number (sip-sip)?

    Hello Scott Page/Alexei/Dirk Anyone.
    I have a question on dial plan:
    Call flow: A---cucm----pgw----voicemail
                  B-----|
    Its a sip to sip call, what i need to do is change the redirect number or rather add a digit to the redirect number at the PGW side.
    For instance:
    A number: 902228990
    B number: 902228996
    Redirect number: 92228996  --->Here i want to change it to 902228996
    pgw patch: 9.8.2    "Patch:"CSCOgs014/CSCOnn014""
    bash-3.00$ uname -a
    SunOS tcs-tza1 5.10 Generic_127127-11 sun4u sparc SUNW,Netra-440
    I checked from the cisco website but i think its only for isup sip calls only but not sure.
    numan-add:fullnumbertrans:svcname="Service Name",numbtype="Number Type", digstring="Original Digits",
    translatednum="Translated Digits"
    Where numtype can be choose 3 for redirect number.
    numtype—Identifier for the number type (1-5), it is one of the following values: 1—called party number 2—calling party number 3—redirecting number 4—calling party number and redirecting number 5—original called number
    Can some help me out with the dial plan configuration?.
    Regards,
    Aby

    Guys,
    This configuration would work?, please let me know
    1. mml> numan-add:service:custgrpid="DP00",name="BATMANredirect"
    2. mml> numan-add:fullnumbertrans:svcname="BATMANredirect",digstring="92228996", translatednum="902228996",numtype="3"
    numtype=3-->redirect number
    3. Adding a result type of NUM_TRANS:
    mml>   numan-add:resulttable:custgrpid="DP00",name="results",resulttype="NUM_TRANS",  dw1="BATMANredirect",dw2="3",dw3="3",setname="setname3"
    dw2--->number type hence i put it 3
    dw3--->NOA--->hence i put it as national ie 3,
    dw4--->Dialplan?-- can i avoid this?
    4. mml> numan-add:resulttable:custgrpid="DP00",name="noar",resulttype="R_NUMBER_TYPE", dw1="4",setname="setname3"
    dw1===>NOA again, i put it as dw1="4" as national.
    Can any of you help me if this would do the trick or anything else needs to be added?.
    Thanks and appreciate your time.
    Regards,
    Aby

  • Changing The Speed Dial Icon [Custom Pic For The Top Sites]

    how do i change the pic for the top sites on the speed dial. can i use a custom images like on chrome or opera??

    You can use virtually any image or link as an email button, the sky is the limit. To do this just insert your image into iweb and click on the inspector button, from here you go to the very last button called the link inspector, enable as a hyperlink and chose an email message. You can then put the url of the email address you wish to link it too. As far as customizing the look I would start with one of the blank page choices. Again to specifically customize the look of your menu or anything else on the page use the inspector. If you want to create your own menu there is an option not to display navigation on your page, and this allows you to have complete control of how your page looks. Create a simple page, open up the inspector, and have some fun creating your own pages. Hope this helps.

  • Changing the defaults when editing limits

    Im creating a bunch of test sequences which all need to be real numbers with three fractional digits.  Is there anyway to change the default settings for when you right click on a step then click edit limits.  It keeps going back to <default> and auto formats my numbers.  Its getting aggravting always switching it to real then deleting seven zeros every single time.  Thanks.

    Hey Roons,
    Are you talking about the Numeric Format dialog box is always going back to default?  I'm not seeing your behavior.  I choose Real for my Type, uncheck Display Trailing Zeros, Number of Fractional Digits = 3, my Format is %$.3f and Custom is unchecked.  Then I click ok and set some limits with 3 fractional digits and click Ok again. 
    Again this is all based on what I set by clicking on the Numeric Format button on the Edit Limits dialog.  Seems to save them fine for me.
    Regards,
    jigg
    CTA, CLA
    teststandhelp.com
    ~Will work for kudos and/or BBQ~

  • Since I upgraded to IOS8, iphone has changed the way it calls via car bluetooth.  Before (IOS8) once I hit 'call' it was transfer to car speakers and i would hear dial tone until answer.  Now, call will only transfer to speakers once call is answered

    Since I upgraded to IOS8, iphone has changed the way it calls via car bluetooth.  Before (IOS8) once I hit 'call' it was transfer to car speakers and i would hear dial tone until answer.  Now, call will only transfer to speakers once call is answered.  This is very incovenient as I never know if my call is going through, and sometimes when call isn't answered immediately I have to look at my phone to cancel the call.  Is there a new setting I am missing?

    Sometimes you turn off your Bluetooth and then back on and it doesn't reconnect with your phone unless you go into the menu. Either way doesn't help much if someone calls you while you're driving and you realize your iPhone is stuck on headphone input.

  • How do I change the format of my workspace it is limited to vertical only?

    how do I change the format of my workspace it is limited to vertical only?

    You really need to be more specific and use terminology from the program. There is no panel called the "edit window." And I can't begin to guess what you mean by "the complete window needed for full video screen." As Steven suggested, a screenshot could really help.
    If you're basically asking how to rearrange the layout of the panels, you can do that by mousing over the divider between any two panels and then clicking and dragging side-to-side or up-and-down.
    See the Workspaces sections of this help document: http://helpx.adobe.com/pdf/premiere_pro_reference.pdf

  • Change the dial prefix on UC560?

    Is it possible to change the dial out prefix to another number besides 9?                    

    Hey,
    This articles gives a descriptive explanation on how to change the dial out prefix
    Configuration of Outgoing Dial Plan on UC500 Series
    Regards,
    Vishal

Maybe you are looking for

  • Hard drive scratching noises?

    I've had my mac book for about 7 months now and i haven't had any problems until now. about a week ago my macbook began to make strange scratching noises whenever i did anything that required a lot of processing power like editing a large photoshop f

  • DSC: Importing Shared Variables results in error -1950679010

    This post is more of an "FYI" rather than a question.  I am using LV DSC 8.2. ASIDE:  I ran into this problem because I was trying to solve a related problem with Deploy Library.vi (I had dependant libraries that deployed manually, but not programmat

  • Tree control - How to get the full path of selected Item in tree control

    I am Flex newbie. When the user clicks the particular item in the tree control I just wanted to get it name along with it's full parent. Here is my XML var dirXML:XML=<root basename="/home/tcegrid"> <Directories> <Dir Name=".autosave" /> <Dir Name=".

  • Multiple files to idoc without bpm

    Hi I have gone through the previous threads and came to know that n:1 is not possible without bpm. But in case of idocs you can collect them in r/3 system itself using RSEOUT00 program. But if my scenario is like.......you have 10 files which are com

  • Getting Dump error for WD ABAP URL, program CX_WDR_ADAPTER_EXCEPTION======C

    Hi SAP WD gurus, Getting the below bump error while launcing the WD ABAP URL on browser. Please help to resolve this. The following error text was processed in system SD1 : An exception occurred that was not caught. The error occurred on the applicat