Cisco 7609-S/ME3600X port shaping
Hello everyone
I am using the folloing configuration on Cisco ME36000X for port shaping
policy-map TEST_OUT_10MB
class class-default
shape average 10000000
policy-map TEST_IN_10MB
class class-default
police 10000000
interface GigabitEthernet0/2
switchport trunk allowed vlan none
switchport mode trunk
load-interval 30
service instance 101 ethernet
encapsulation untagged
service-policy input TEST_IN_10MB
service-policy output TEST_OUT_10MB
bridge-domain 101
interface Vlan101
bandwidth 10000
ip address xxx.xxx.xxx.xxx 255.255.255.252
I have applyed also the same port shaping on an Cisco 7609-S with an 7600-ES+20G3CXL
policy-map TEST_10MB
class class-default
police 10000000
shape average 10000000
interface GigabitEthernet1/11
bandwidth 10000
ip address xxx.xxx.xxx.xxx 255.255.255.252
load-interval 30
service-policy input TEST_10MB
service-policy output TEST_10MB
When i am downloading a file and capturing the traffic with wireshark there is significant difference on Cisco 7609-S graph with that one on Cisco ME3600X. Both have the same internet connection.
Is there any way to fine tune Cisco ME3600X to have the same behavior like Cisco 7609-S?
Regards
Antonis.
I have not that graph so I am just guessing that you are noticing the difference between policing and shaping. It seems to me you are applying these techniques on each platform on a different way. Try to shape/police in the same order or only to shape.
Hope to help
Alessio
Sent from Cisco Technical Support iPad App
Similar Messages
-
Cisco 7609 router received higher traffic than upstream provider router is sending
Hi all,
I have a Cisco 7609 router that connects to our upstream provider router using 3rd party DWDM Fiber backhaul provider.
The upstream provider router is a Juniper router that had capped our port speed to 1.1Gbps, the backhaul provider didn't capped our port speed and the maximum speed is 2Gbps since it's a 2x1Gbps port channel interface.
I have noticed that our 7609 router able to receive traffic that exceeds 1.1Gbps, and the highest traffic able to received is 1.3Gbps and more.
I have crossed checked the MRTG graph provided by our upstream provider as well as our PRTG graph and indeed we are receiving higher bandwidth than our upstream provider is sending.
I'd like to know if anyone know how it is possible to receive traffic that is higher than what the neighbor router is sending?
RegardsHi at all,
We found a solution for this Problem !!
We always and always got this error:
%PQUICC-1-LOSTCARR: Unit 0, lost carrier. Transceiver problem?
The problem was the cable! The following pin-out is required:
1 ----- 1
2 ----- 2
3 ----- 6
4 ----- 5
5 ----- 4
6 ----- 3
7 ----- 7
8 ----- 8
We used this and the fault has disappeared!!
The only problem that still exists:
After the first connection the router must be rebooted because otherwise no more additional session is established.
Thanks for all answers.
Regards,
Mario -
Ethernet cfm: question on RDI allarm cisco 7609
Hi all,
I have ethernet cfm configured on two Cisco 7609s and two UP MEPs configured under xconnect PW MPLS on the same domain, level and service MA so they became CFM peers.
I notice that after removing and re-configuring olny one UP MEP under xconnect PW, the Cisco 7609 send a SYSLOG message indicating a RDI defect alarm and the show ethernet cfm errors showed RDI defect too.
Aftert 18 seconds this alarm is cleared and the show ethernet cfm errors is empty.
I don't undestand this behaviour..why the Cisco send the RDI alarm in this situation?Have you opened a TAC case for it ?
Can you share output of:
show module 1 -
Best way to connect 2 Cisco 3750 PoE 24-port Switches
Hello. I have 2 Cisco 3750 PoE 24-port switches in a small office environment. Right now I have a trunk configured off my ASA 5505 to switch 1, and then just an access port configured on a port (switch 1) and an access port configured on a port (switch 2) to connect them together. These switches also have 2 GB SFP ports but they are not being used in this configuration.
I was curious to know if anyone had any better recommend configurations for connecting these 2 switches together? I'm not sure if this particular model can be stacked?What are the exact model numbers (should be written on a sticker)?
You will know if they can be stacked as you will see the 2x stack ports on the back of each switch :)
If they can then that is probably the way to go unless you want to keep them as separate switches for some reason.
If you want them separate, I would connect them via a Trunk link at least so you can have the same Vlans on both.
Thanks -
I have a cisco 7609 router it Communication Media Module WS-SVC-CMM card,when i do (show module) im seeing the card there but when i want to configure the card like i type (card type the iso is not recognising it but i downloaded the latest version of the IOS and upgrade it but stiil,can any one help.
try 12.2 SB series.
regards
shivlu jain -
No cisco phone with voice port?
Hi
could any one advice me about "switchport voice vlan"?
I have a configuration like:
interface GigabitEthernet 1/-/1
description test phone
switch port access vlan 100
switchport mode access
switchport voice vlan 200
when I plug a no-cisco phone into this port, the phone try to get dhcp from vlan100, not vlan 200.
do I have any chance to force it go to vlan 200? o
Any comments will be appreciate
Thanks in advance
julxuHi
Most IP phones have some mechanism for setting the VLAN - Cisco phones use CDP, but other phones do not. Check with the manufacturer, or post up the type of phone you have.
For example, some phones require you to set custom DHCP options to set the VLAN.
Aaron HarrisonPrincipal Engineer at Logicalis UK
Please rate helpful posts... -
Need SNMP OID for MSTP status in Cisco SG300-28MP 28-port Gigabit Max-PoE Managed Switch
Hi,
I have configured redundant network using two Cisco SG300-28MP 28-port Gigabit Max-PoE Managed Switch through MSTP & it's working fine.
I need OID of MSTP status from which I can monitor which Switch is active and which one is in standby mode.
Please help.
Thanks,
HarshaHi Harsha,
check these OID's:
http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?objectInput=1.3.6.1.4.1.9.9.500.1.2.1.1.6&translate=Translate&submitValue=SUBMIT
http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?objectInput=cRFStatusUnitState&translate=Translate&submitValue=SUBMIT&submitClicked=true
Thanks-
Afroz
**Ratings Encourages Contributors *** -
Need SNMP OID of MSTP status for Cisco SG300-28MP 28-port Gigabit Max-PoE Managed Switch
Hi,
I have configured redundant network using two Cisco SG300-28MP 28-port Gigabit Max-PoE Managed Switch through MSTP & it's working fine.
I need OID of MSTP status from which I can monitor which Switch is active and which one is in standby mode.
Please help.
Thanks,
HarshaHi Harsha,
check these OID's:
http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?objectInput=1.3.6.1.4.1.9.9.500.1.2.1.1.6&translate=Translate&submitValue=SUBMIT
http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?objectInput=cRFStatusUnitState&translate=Translate&submitValue=SUBMIT&submitClicked=true
Thanks-
Afroz
**Ratings Encourages Contributors *** -
Please suggest one Gigabyte switch for replacing Cisco 2960 G 48 port
Dear all,
Cisco 2960 G is seems to be end of life.Please suggest one switch with same feature of Cisco 2960 G 48 port, with same prize
Thanks
Ashik A S
9605395605Disclaimer
The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
Have you looked at the newer/current series of 2960s? -
ME-3400, drop with port shaping
Hello.
We have a ME-3400 with IOS Metro IP.
The giga0/1 and gi0/3 ports are configured all the same with qos policing (input policy-map) and port shaping+Class Based Priority queueing (output policy-map).
We have no drop on gi0/1 output.
On gi0/3 output the drop is about 1-2% although the traffic (for example 10Mbps) is much less than the port shaped bandwidth (for example 200Mbps).
Can anyone help me?
Thank you.Hello, sure we can.
1. Check the output policy map using "show policy-map interface gi 0/3 output" command. This should say exactly where packets are dropped.
2. Check the parameters. In the output the first line should say the following:
Service-policy output: XYZ
Class-map: class-default (match-any)
8645541 packets
Match: any
Traffic Shaping
Average Rate Traffic Shaping
CIR 11111120 (bps)
Output Queue:
Max queue-limit default threshold: 48
Tail Packets Drop: 0
Service-policy : ABC
Class-map: core-queue1 (match-any)
3321747 packets
Match: cos 5
Priority
police cir 1000000 bc 31250
conform-action transmit
exceed-action drop
conform: 0 (packets) exceed: 0 (packets)
Output Queue:
Max queue-limit default threshold: 48
Tail Packets Drop: 0
The bold values are critical - low buffers means high drop probability.
Remember - interface never sends data at any other rate than it's physical rate, meaning "LOAD" is just an average of how many bytes transferred over what time.
So if 1000 packets will arrive in one milisecond, and then you have no traffic for 10 seconds, average will be low load, but 1000 packets will not fit in 48 buffers and 952 packets will be dropped.
Increase buffers! use the following guideline: calculate how many packets can be sent in 10ms window, and increase the buffers accordingly. E.G for 100Mbps 1 Mb can be sent in 10ms, which is 1Mbps/8 = 125000 BYTES. With "packet" size of 250 (buffers are per packet but their size is limited) that's 500 buffer places, or 500 packets buffer.
3. Always pay attention to BC and TC values
Bursts will definitely be your problem -
Cisco 7609 - optical gigabit interface
Hi all,
I have a strange problem with the optical gigabit interface of a Cisco
switch 7609. This is the problem:
I have two 7609 cisco switch (A and B) cross connect with a optical
fiber.
All port of both switches are configured as followed:
switchport
switchport mode acces
shutdown
no cdp enable
no ip address
end
With the same optical fiber cable i have connect two ports of the switches and I brough up the interface.
I got the following result if i run 'show ip interface brief' on the switches:
SW A - SW B
port 1 - port 1 --> link down protocol down
port 2 - port 1 --> link up protocol up
port 1 - port 2 --> link up protocol up
port 2 - port 2 --> link up protocol up
Why if i connect port 1 on both switches the link don't brought up?
Have anyone some idea for the possible cause of the problem?
Thank you
BR
\SergioTry:
http://www.cisco.com/en/US/products/ps6902/products_implementation_design_guide_chapter09186a008062f863.html -
Cisco 3548 xl and ports broken
Hello could you please help me.
we have several ports broken in cat 3548 xl ( fast 35,37,38,39) when we are trying to connect new workstations to them, ports do not work.
there is over 80 procent packet loss.
all other ports work ok.
Do you konw if there is a known problem in cat 3548xl's. ( could not find anything in bug toolkit)
our version is flash:c3500XL-c3h2s-mz-120-5.3.WC.1.bin
Model number: WS-C3548-XL-EN
System serial number: FAB0534M322
i thank you in advance,
best regards,
SusannaHello all and thank you for the replies !
i can now open the referred cisco-page. I will check the page
Here are anwers to all questions. we will boot the switch as soon as possible and see what happens.
do you know a good debug command what to use to see if port is acting wrong ?
i know it is not a duplex problem, since we have had a lot of duplex problems ( and this is a different case). All the other ports seem to work fine ( except for 35,37,38, 38)
laptop had only 10/100 nic and it works fine with another 3548 ( next to the 'faulty switch).
both the printer and laptop had same kind of problem.
Here are the tests
1) first the switch port and printer had auto config ( auto speed/auto duplex) in ports/ nic.
--> only 20 % of pings succeeded.
sometimes ping succeeded 10 times and then there was 30 fialed ping-packets.
2) then printers configuration was changed to 100/FD. the link started to work ( ping succeeded 100%) the switch had still auto speed and duplex, and therefore switch had only 100/HD.
when i changed switch port to 100/full, printer lost its network connection and did not answer at all to pings.
3 ) when i changed the switch port back to auto ( autospeed/auto duplex) the printer did not start to work again.
when swicth and laptop/printer were configure to auto, switch saw the port as 100/FD, negotiation was ok. as soon as data was going to the port, connection stopped working.
here is the show int . it is down, since we cant use the port at the moment. but as you can see there are no errors
BTW the printer and laptop work fine in the same switch in port 41.
best regards TIA ! Susanna
FastEthernet0/38 is down, line protocol is down
Hardware is Fast Ethernet, address is 0007.5070.5d26 (bia 0007.5070.5d26
MTU 1500 bytes, BW 0 Kbit, DLY 0 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Auto-duplex , Auto Speed , 100BaseTX/FX
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output 2d17h, output hang never
Last clearing of "show interface" counters 2d21h
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
12126 packets input, 2217643 bytes
Received 918 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 101 multicast
0 input packets with dribble condition detected
32145 packets output, 3533981 bytes, 0 underruns
0 output errors, 0 collisions, 50 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out -
Issue in Sub-interface traffic on cisco 7609-s router
Hello please support,
I configured sub-interfaces and it is working properly, but some time sub-interface show traffic more then physical interface .
Like
int gi 3/32 0.13 Mbps 12:00 PM
int gi 3/32.11 855 Mbps 12:00 PM
as per my knowledge physical interface have cumulative traffic of all sub-interfaces.
interface GigabitEthernet3/32
no ip address
interface GigabitEthernet3/32.10
encapsulation dot1Q 10
ip address 172.20.128.77 255.255.255.252
ip ospf network point-to-point
ip ospf bfd
bfd interval 50 min_rx 50 multiplier 5
no bfd echo
no cdp enable
interface GigabitEthernet3/32.11
description interlink MPLS
encapsulation dot1Q 11
ip address 172.20.129.73 255.255.255.252
ip ospf network point-to-point
mpls ip
mpls label protocol ldp
Regards,
Damodar NagarI have not that graph so I am just guessing that you are noticing the difference between policing and shaping. It seems to me you are applying these techniques on each platform on a different way. Try to shape/police in the same order or only to shape.
Hope to help
Alessio
Sent from Cisco Technical Support iPad App -
Cisco Prime: Event Larm Port 'x' is down on device.
Hi,
I'm writing regarding; event-larms; that is reporting from Cisco Prime; connected to controller. Interfaces is reporting via event-larm; that they are down.
"Virtual Domain: ROOT-DOMAIN
PI has detected a change in one or more alarms of category Controller and severity Critical in Virtual Domain ROOT-DOMAIN.
The new severity of the following items is Clear:
1. Message: Port '3' is down on device '10.1.1.2'.
(6 times)
2. Message: Port '4' is down on device '10.1.1.2'.
(6 times)
3. Message: Port '5' is down on device '10.1.1.2'.
(6 times)
4. Message: Port '6' is down on device '10.1.1.2'.
(6 times)
5. Message: Port '7' is down on device '10.1.1.2'.
(6 times)
6. Message: Port '8' is down on device '10.1.1.2'.
(6 times)
E-mail will be suppressed up to 30 minutes for these changes."
Is there a solution how to not recieve those event-larms? The only LACP interfaces that is configured is 1 & 2, in a group.
See attached screenshot, when trying to disable the other interfaces.
The LACP is enabled and configured on "management" interface.
Best Regards,
DavidFrom: https://supportforums.cisco.com/discussion/12077376/prime-infrastructure-alarm-port-down#comment-9405836
"As far as I understand the error message you only need to disable SSO before you can disable the LAG ports."
"(Cisco Controller) >config port adminmode 3 disable
Blocked: Lag is enabled. Disabling the lag port is blocked when system is in redundancy state (SSO)"
"I would suggest to do this only in a maintenance window." -
Cisco 4900M integrated X2 ports, CVR-X2-SFP10G and SFP-10G-SR
Hi,
We are going to order two(2) cisco 4900M switches for core and twelve (12) 2960S switches for access (4 stacks with 3 switches each), connected to the core with 10G MM optical paths (up to 300M each). In addition I have one gigabit half-card but it is not related to my questions here. Please see my attached diagram.
So my questions are:
1. Point 1.Can we use integrated eight X2 ports of every of the both 4900M switches as plugging into four of them four convertors CVR-X2-SFP10G and to plug on every of the convertors sfp tranceivers SFP-10G-SR - as it is described on the diagram, or I need for something more in addition to described? I found only some minimum soft releases to use as requirement to use these convertors and sfp tranceivers, but is there something additional I need?
Note:I'm asking that because Dynamic Conf Tool doesn't give me to do such configuration, actually these convertors and SFPs are missing there at all, but it sometimes happens with some products... In documentation it is described this should work (if I didn't pass something which is my main consern and why I'm asking here).
2.Point 3.If this shouldn't work, the other alternative (not described in my diagram) is to use X2-10GB-SR modules without any SFPs - just ot use SC connectors for the optical cables instead of LC. So my question in that case is will 10G links work between X2-10GB-SR at one side and SFP-10G-SR at the other side where I have 2960S switches and this is the only option? Is is expected to have some problems in that scenario?
Note:Actually if Point 1 is workable I prefer to use it instead of Point 2 because of minor price optimization when using SFPs with convertors in comparisson to X2-10GB-SR.
3. If the both variants are possible, which one is preffered and why, what advantages does it have (for example low latency of something else)?
Thank You in Advance
AsenJust for your information, a fiber link does not care if one end of the fiber has an GBIC (SC-type connector) and the other end has a SFP (LC-type of connector); or any other transceiver footprint (X2, CFP, etc.).. The thing that is important is that each module is the same specification, and matches the fiber type and link length of the network (10GBASE-SX in this example).
Good luck.
Maybe you are looking for
-
IMac refuses to boot properly - hardware problem?
Hi all, I'm having some problems with my iMac (purchased last October) and was hoping some kind soul could shed some light. Here's where I'm at now. - The iMac doesn't boot. When I press the power button, it chimes, but then nothing happens and I jus
-
How to view the OM infotypes number
Hi Experts, How and where can i see the infotype number in OM? Regards TS
-
Can bad PRAM (CMOS) battery be "guilty" for MBP not recovering from sleep?
I have MBP 4.1 (last with removable battery) and it wont recover from sleep... i tried reseting SMC but no effect (three months ago SMC reset worked well for me). I tried removing/inserting RAM, HDD, CMOS Battery but nothing can make my MBP recover f
-
Fm9p237, probs with Save As PDF, turns *some* anchored frames blue
I am using Save As PDF because have to create CMYK PDF. I know how to do that. The issue now is that FrameMaker is sticking blue boxes around only *some* of the graphics. They are all EPS graphics imported by reference into anchored frames. These box
-
Any way to throttle photo upload?
After upgrading to 10.10.3 and Photos, it seems that the upload of my library to iCloud is consuming all of my available bandwidth, to the point where my Mac and any other device in my house has become unusable. In Activity Monitor, nurlsessiond is a