Creating an infotype composed of standard infotypes parts

Hello all,
My purpose is to created an infotype to gather several fields of some standard infotypes.
In order to do this, I started to create a new infotype 9000 copying one of the infotypes whose fields where needed in the new one.
Now I just want to add my new infotype some fields belonging to another ifp. Is it possible to add a part of a standard ifp to my new one or do I have to add my fields one by one ?
Thanks everyone,
Sylvain

Hi Sylvain
Let me draw what I see. Do you want to maintain e.g. persg, pesk from IT0001, vorna, nachn from IT0002, stras from IT0006 together from another customer infotype?
If so, generating an infotype will not have much for this. Because it will bring lots of integration problems (think of validity periods).
Regarding your proposal:
P9000 has following fields:
persg
persk
vorna
nachn
stras.
Then do not expect that it can maintain data of PA0001, PA0002 and PA0006. It will just maintain PA9000 unless you code more functionality which more or less is dialog programming. If you want just PA9000 to be filled, then you will lose many functionalities of HR system.
Since IT9000 is your own infotype, why do you need to append a customer include? If it is eligible, you can prefer appending CIs to standard infotypes.
Regards
*--Serdar <a href="https://www.sdn.sap.com:443http://www.sdn.sap.comhttp://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.sdn.businesscard.sdnbusinesscard?u=qbk%2bsag%2bjiw%3d">[ BC ]</a>

Similar Messages

  • HELP CREATING ADDITIONAL FIELDS  WITH  DROPDOWN IN STANDARD INFOTYPE

    HI ALL,
    I AM IN ABAP-HR.
    I HAVE 2 THINGS 2 ASK MY FRIENDZ..
    1). I WANT TO ENHANCE STANDARD INFOTYPE...
    I  WANT TO PUT ADDITINAL FIELD WITH DROPDOWN...
    I CAN PUT ADDITIONAL FIELD BUT I DONT KNOW HOW CAN I DO WITH DROPDOWN...
    2).
    OTHERTHING I WANT TO CHANGE THE TEXTFIELD OF STANDARD INFOTYPE..
    I MEAN 2 SAY CHANGE TEXT 'BIRTHDATE' TO 'DATE'..
    CAN U PLZ HELP ME OUT 4 THIS....
    WAITING 4 FAVOURABLE REPLY..
    BBYE..

    Hello Bhumit,
    1) to check how to bring values to a dropdown please refer the standard demo report programs in se38
    a)DEMO_DROPDOWN_LIST_BOX
    b)demo_dynpro_dropdown_listbox.
    2)We need to understand that if the field label 'BIRTHDATE' is from a standard screen then the approach is to go to that particular screen ...delete the text and put our own text there as 'DATE' ..otherwise if the field is a custom field we can change the name in the field level or domain level
    Pls check,revert and reward if helpful
    Regards
    Byju

  • Enhancement to a standard infotype

    Hi all,
    I have added a check box to the standard infotype 0022
    provided with function code.
    i have used
                           program : ZP002200
                           screen : 200
    but it is inactive when i try to create a record in pa30
    so i want to know how to make these radiobuttons and check boxes active.

    Hi all,
    I have added a check box to the standard infotype 0022
    provided with function code.
    i have used
                           program : ZP002200
                           screen : 200
    but it is inactive when i try to create a record in pa30
    so i want to know how to make these radiobuttons and check boxes active.

  • Enhance screen for standard infotype

    I need to enhance screen for standard infotype. I follow docs but nothing happens.
    Here is my process by steps:
    1. PM01 - select infty number
    2. PM01 - generating CI_PXXXX (customer include)
    3. create structure for this include
    4. create customer screen for this include
    5. PM01 - generate objects.
    Then I am redirected to SE19 - BAdI-Builder. What should I do follow?
    Created screen hasn't appear in se80 (MPXXXX00).
    Thank you in advance!

    I suggest you place your question in [ERP HCM forum|SAP ERP Human Capital Management (SAP ERP HCM);,

  • How to push custom infotype details to Standard Log Report

    Hi Experts,
    i am using S_AHR_61016380 SAP Standard Report for Log Change Data in
    the report development. However, the standard report for logged changes
    does not capture the long term documents run for the custom infotype.
    it is only giving the logged changes for the standard SAP infotypes
    and it doesnot capture any details for the custom infotype.
    We are looking a possibility on how to push custom infotype details to S_AHR_61016380.
    Pls suggest in case you have any inputs for the same.
    Thanks & Regards,
    Kishore.

    Hello Amith,
    As u said i have created a Z program, and also i have used the following FMs.
    1. 'HR_INFOTYPE_LOG_GET_LIST'
    2. 'HR_INFOTYPE_LOG_GET_DETAIL'
    Using these FMs i am able to get log records from the standard infotypes but i am unable to fetch data from the custom infotype tables.
    Please give me any solution to read the log records from the custom infotype tables.
    Thanks,
    Kishore

  • Facing problem with call subscreen area in standard infotype

    Dear SAP Guru's,
    I have enhanced standard infotype 0185 from PM01, in assign enhancement tab it create multiple screens ,
    my program name ZP018500, screen number 0200 generated,
    on  0200 screen i need to display two subscreens tfor that
    i have created subscreen area  on srcreen 0200 which is already a subscreen.
    and i am calling two subscreen 0201 and 0202 on that  subscreen area.
    while creating entries for 0185 infotype  my screen keep going in continious loop for call subscreen statement on 0200 screen number.
    roll in fail, session terminated error coming because of this.
    is it correct to create subscreen area on subscreen and calling subscreen on that.
    Guide me to solve the issue.
    Thanks and Regards,
    Syed

    Dear Gopal,
    Thanks for the reply,
    But i can't make 0200 screen as normal screen because it is automatically generated by system while enhancing the standard infotype,
    Please let me know any other solution.
    Regards,
    Syed Taj

  • Showing fields of Custom infotype in standard infotype screen

    Hi Experts
      I have created a custom infotype 9xxx. Now when I go to the PA30 maintenance screen for a standard infotype 0795, i should also see the fields from custom infotype 9xxx. Can you please let me know how I can enhance the standard infotype 0795, since SAP does not allow me to change it directly.
    Thanks
    Neo

    Hi,
    I'm gonna be an *ss and ask why you wanna see the fields of your 9xxx - infotype in SAP IT0795.
    If this is for information purposes, I believe this should be incorporated in reporting and not within master data infotypes.
    Wilfred.

  • Adding Standard Infotype fields to Custom Infotype

    Hi,
    I have a Requirement where I've created a Custom Infotype. Now, client needs to add Standard KOSTL and Email Address fileds to it. Whenever, someone tries to create / change this Custom Infotype for any Employee, the Pernr's  KOSTL and Email Address should get populated automatically as in Standard Infotypes 0001 and 0105.
    Please guide me, how to achieve this functionality.
    Regards,
    Hems.

    Hi Salman,
    Thank you for your valuable information. I haven't Configured Dynamic Actions yet. Is it simple to write the Logic for Dynamic Actions. Is this the only way to solve this Issue?
    I tried by adding the standard fields, but they are not populating the values; but just appearing as Input Fields with Input help option.
    Please let me know if you have any suggestion in this direction?
    Regards,
    Hems.

  • Adding Standard Infotype to custom Infotype

    Hi All,
    I got a requirment,pls let me know the procedure to do same....
    I have to create Custom infotype with all fields of the given Standard Infotype ...and the custom fields given by client.........
    pls tell me how to procedd and do the needful.
    Thanks for the same.

    From PM01.
    For more help You may take help from :
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/c0aefeb4-85c9-2910-f0a0-c2ad78148e18

  • Create IT2013 entry with the decoupled infotype framework

    Hello,
    I tried to create an IT2013 (Quota corrections) entry with the new decoupled infotype framework but I didn't success.
    I first tried by using if_hrpa_masterdata_bl->get_infty_container to get a container (and then change it and save it) but I get an error because the time constraint for IT2013 is set to 'Z' and the framework don't handle it.
    So I guess this is because if_hrpa_masterdata_bl and other related classes/interface can only be used for PA and not for Time.
    Therefore I tried to find Time infotypes dedicated classes and I found some.
    The most interessant one is CL_PT_BLP_IT2013. It looked perfect, with everything I needed, but it doesn't work: when CL_PT_BLP_IT2013->IF_HRPT_BLP_INFOTYPE~GET_INFTY_CONTAINER is called, it tries to create an instance of CL_HRPT_INFTY_TIME_CONTAINER but raises an exception. Not surprising because the only non-commented line its constructor executes is:
    METHOD constructor.
      RAISE EXCEPTION TYPE cx_hrpa_violated_assertion.
    *  if_hrpa_infty_container~a_tclas          = 'A'.
    *  if_hrpa_infty_container~a_pskey          = pskey.
    *  if_hrpa_infty_container~a_infotype_logic = infotype_logic.
    ENDMETHOD.
    Moreover, the description of the class CL_HRPT_INFTY_TIME_CONTAINER is: "DO NOT USE! HR: Time Data Container", so it's not suprising at all it doesn't work.
    I found some other Time infotypes related classes like CL_PT_BLP_INFOTYPE or CL_PT_TD_INFOTYPE but I couldn't figure out how to create a new IT2013 entry with those ones.
    At the end of the day, I couldn't find any way to create a new IT2013 entry using the decoupled infotype framework.
    Can someone please help?
    Thanks in advance.
    Mathieu

    Hi,
    The time infotypes 2XXX are not yet decoupled as per the standard infotype framework. Hence there are no decoupled classes delivered in standard.
    Regards
    Roy
    SAP Labs

  • Enhance Standard Infotype 1005 in HR

    Dear All,
    Please suggest how to enhance standard infotype 1005 - Planned Compensation in HR.Transcation PM01 is not allowing to do so ...as no CI include is attached for the same.
    Please guide.
    Regards,
    Subhash

    hi,
      maybe you can achieve your requirement by creating a new custom OM infotype
    ( if the custom information are linked to the OM entity :  org unit, positions.. ) or a new PA infotype ( if the custom information are linked to the employee ) .
    Regards luigi
    Edited by: luigi la motta on Sep 2, 2011 11:46 AM

  • Sending custom field added in Standard infotype through idoc

    Hello All,
    We have a requirement where custom field of a standard infotype 0002 needs to be sent through idoc only to a desired destination system.
    My Approach:
    I have created a custom segment having custom field from IT 0002 & mapped this segment in T777D table.
    But the problem with above, is all the system who are receiving IT0002 will be receiving this custom segment also including desired system.
    How can it be filtered?

    Hi,
    Create the new segment and message types of the idoc with cutom field.
    Then map the new mesage type and corresponding receiver( SM59).

  • Customer message for  Standard Infotype 0050 field Standard overtime

    Hi Guyz,
    For the Infotype 0050 field Standard Overtime(ZMGEN) , I need to restict with values Y or N. Otherwise Error 'Invalid Code entered' should be displayed.
    How do I approach ?
    Thanks and Regards,
    Venkat.O

    The best option might be to create a field exit. Use report RSMODPRF to create field exit for Data Element DZMGEN. The report has a good help document, but it's pretty easy to set up the field exit.

  • Wrapping standard infotype with customer dynpro

    Hello,
    I'd like to change the values in standard fields based on the values from the customer fields.
    I'd like to do this when DELIMIT runs in PA30.
    I'm thinking of wrapping the standard infotype with a customer dynpro.
    Does anyone know if this is possible?
    Could I use the customer dynpro to do all the value changes but still use the standard input checks?
    Thanks and Regards,
    Yosuke

    The best option might be to create a field exit. Use report RSMODPRF to create field exit for Data Element DZMGEN. The report has a good help document, but it's pretty easy to set up the field exit.

  • Need to create maintenance view for a custom infotype

    A custom infotype 90XX is created. The data cannot be modified or created through PA30 in this infotype. Through PA 40 actions only we can create/change the record/data. We have created some 1000 records in it. Now can we create a maintenance view for the infotype so that we can create, delete or change the data in the infotype as and when we want.

    Hi,
    pls chk dat u have maintained the 'Infotype Charecteristics' and 'Technical Attributes' correctly.
    thanks,
    teja.

Maybe you are looking for

  • HT201209 Can I move money from one Apple ID to another?

    I'm hoping I can somehow transfer my iTunes gift card money!

  • Streaming Netflix via Pro to TV

    Hello, I would like to stream movies from Netflix on the Macbook Pro to my TV. I bought a Moshi Mini Displayport to HDMI Adapter and plugged into the laptop. I then removed the HDMI cable from my DVD player and plugged it into the adapter. I followed

  • Upgrade from 46c to ECC6.0 : Java or Java-AddIn ?

    Hello Can you explain me what is the difference between Java and Java-AddIn as proposed in evaluation phsae of an upgrade from 46c to ECC6.0? Thank You.

  • Repeating records for element values

    Hi, Need to get element input values,i have used pay_element_entry_values table to get he screen inpout value.Used the effective date to filter,still 2 records are fetched. E.g query SELECT DISTINCT papf.national_identifier, papf.employee_number, pap

  • Need help troubleshooting Kernel panics

    Hi, I have had two Kernel Panics in two days just now, and another one a few weeks ago. The logs don't help me as I am not familiar with the wording on the Mac side, and I cannot submit the error reports to Apple as it fails, probably because I run 1