Customs alerts when a port-channel is down.

Hi,
I want to receive syslog alerts when a  port-channel is down, or when a interface from the port-channel is down  or if is possible to know when a neighbors is unreacheable or lost.
Is  possible?? I have tried to configure Automated Actions in the tool  syslogs on RME (LMS 3.2) when a interface is down (LINK-*-3-UPDOWN:*  LINK-*-5-CHANGED:* LINK-*-5-UPDOWN:*), but I received alerts messages  from others interfaces when only I want the interfaces that form the  port-channels.
Thanks,

Disclaimer
The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
Liability Disclaimer
In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
Posting
Well if it's the only remaining channel link, the port-channel goes down.  If not the only remaining channel link, the port-channel continues without it.  As you note, you lose bandwidth and I believe traffic will be rehashed across the remaining channel links, which can result in less optimal load distribution.
Protocols like STP or a routing protocol shouldn't see a link outage or flap.

Similar Messages

  • Alert when Sender Communication channel is inactive/down

    Hi,
    Kindly let me know if we can generate an alert using alert configurations/rules when Sender Communication channel is inactive/down.
    Thanks.
    Regards,
    Aditya.

    May be in the channel monitoring the channel is stopped. If you are sure that the channel is active in ID and in Start mode in communication channel, then it is a cache issue. Then, perform full CPACache refresh.
    Regards,
    Prateek

  • SAN Switch 9148 UPG procedure when using Port Channel

    Hi,
    I am kind of new to the UPG procedure of Cisco Switch, and the customer i am working with is using Port Channel.
    Do i have to shutdown the port channel before executing the switch UPG or if everything can stay up?  Will i lose connection when the UPG will proceed ?
    If anyone has some documentation that describe the process, it would be much appreciated.
    Thank you
    Christian

    Hi,
    I am kind of new to the UPG procedure of Cisco Switch, and the customer i am working with is using Port Channel.
    Do i have to shutdown the port channel before executing the switch UPG or if everything can stay up?  Will i lose connection when the UPG will proceed ?
    If anyone has some documentation that describe the process, it would be much appreciated.
    Thank you
    Christian

  • Raising alert when JMS Messaging Bridge goes down

    Hi
    I am using Oracle FMW 11g and have implemented Messaging Bridge. Things are working fine now.
    My requirement is whenever the Messaging Brdige goes down or goes into Inactive state, i wanted an alert / notification to be generated so that some action can be taken
    Can some one send me the related inputs to implement the same
    Thanks
    vamsi

    Hi Inaki,
    Thank you for the note. but this feature is available from 7.3 SP13 but we are on 7.3 SP4.and it is very difficult to upgrade to SP13.
    For us the webmethods will place the messages in their queue and PI pick those messages using the Sender JMS channel with following configuration,
    transport protocol:Access JMS provider Generically
    Message protocol:JMS1.X
    Is there any other solution to trigger  an alert when the thread is hung? Also is it possible to auto referesh a channel?
    Regards,
    Deepa

  • Lacp port channel shows down on one 5k

    I got one side of my lacp port channel down.
    the topology is shown but the left side is showing down
    20    Po20(SD)    Eth      LACP      Eth1/5(s)    Eth1/6(s) 
    # sh int port-channel 20
    port-channel20 is down (No operational members)
      Hardware: Port-Channel, address: 547f.eebb.644d (bia 547f.eebb.644d)
      Description: **To-VA-7004**
      MTU 1500 bytes, BW 100000 Kbit, DLY 10 usec
      reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA
      Port mode is trunk
      auto-duplex, 10 Gb/s
      Input flow-control is off, output flow-control is off
      Switchport monitor is off 
      EtherType is 0x8100 
      Members in this channel: Eth1/5, Eth1/6
      Last clearing of "show interface" counters never
      30 seconds input rate 80 bits/sec, 0 packets/sec
      30 seconds output rate 176 bits/sec, 0 packets/sec
      Load-Interval #2: 5 minute (300 seconds)
        input rate 112 bps, 0 pps; output rate 288 bps, 0 pps
      RX
        4286 unicast packets  785765 multicast packets  1493093 broadcast packets
        2283144 input packets  248607161 bytes
        13 jumbo packets  0 storm suppression bytes
        0 runts  0 giants  0 CRC  0 no buffer
        0 input error  0 short frame  0 overrun   0 underrun  0 ignored
        0 watchdog  0 bad etype drop  0 bad proto drop  0 if down drop
        0 input with dribble  0 input discard
        0 Rx pause
      TX
        0 unicast packets  3397636 multicast packets  0 broadcast packets
        3397636 output packets  399463036 bytes
        0 jumbo packets
        0 output errors  0 collision  0 deferred  0 late collision
        0 lost carrier  0 no carrier  0 babble 0 output discard
        0 Tx pause
      2 interface resets
    sh run interface port-channel 20 membership 
    !Command: show running-config interface port-channel20 membership
    !Time: Mon Feb  2 23:04:37 2015
    version 5.1(3)N2(1b)
    interface port-channel20
      description **To-VA-7004**
      switchport mode trunk
      switchport trunk allowed vlan 1,200-202,251
    interface Ethernet1/5
      description **TO-VA-7004-ETH3/45**
      switchport mode trunk
      switchport trunk allowed vlan 1,200-202,251
      channel-group 20 mode active
    interface Ethernet1/6
      description **To-VA-7004-ETH4/46**
      switchport mode trunk
      switchport trunk allowed vlan 1,200-202,251
      channel-group 20 mode active
    but on the right side everything is up, 
    20    Po20(SU)    Eth      LACP      Eth1/5(P)    Eth1/6(P) 

    It seems have a problem on interfaces => 20    Po20(SD)    Eth      LACP      Eth1/5(s)    Eth1/6(s) 
    Can you share us the status about interfaces 1/5 - 6 & 3/45, 4/45 of 7k?
    Do you have configured per Ethernet interfaces or on the Po ?

  • Wlc 5508 get error when use port-channel

    We have two wlc in the system 5508 and 4402.
    we config HA for 2 wlc, both wlc enable LAG
    When I connect 2 interface  of 5508 to 2 interface (in a port channel mode on, trunk, dot1q) of a
    couple of VSS switch, I cant management 5508 through web any more, and I still can do with 4402.
    If I  shutdown 1 port int the port-channel, it work well.
    Do you know what happen ?
    Thanks
    Duyen

    hi Scott,
    We have VSS ( 2 x 6509) trunk with (2 switch 4506).  one port of wlc4402 connect to one port of one swith 4506.
    2 ports of wlc 5508 conect to 6509, each port connect to one switch 6509.
    the config in VSS switch like this:
    interface gig1/1/1
    switchport trunk encapsulation dot1q
    switchport mode trunk
    channel-group 500 mode on
    interface gig2/1/1
    switchport trunk encapsulation dot1q
    switchport mode trunk
    channel-group 500 mode on
    etherchannel load-balancer src-dst-ip
    ( I dont see this command in running config)

  • Raising an Alert ,when the Legacy system is down

    Hi,
      I want to raise an Alert or some thing when my Source Legacy system is down.
    My scenario is  File -to - IDOC .  I'm getting all the XML files from the FTP server. so, My source system is FTP srever . Due to network problem or some other problem  my FTP server is  getting down very frequently. Now i want to send this information to respected persons in a automated way.
    Is there any option that know  the Legacy server status , How can we  know that FTP server is down .
    Please suggest me some solution for this type of prblems.
    Regards
    Jain

    Hi
    You can use BPM and check whether the system is up or nt (using the Connection FM STFC_CONNECTION )
    In case of system errors and application errors you can use alerts.
    System error: Runtime errors, mapping errors , application system is down, Adapter engine is down etc....
    application error: If you are checking some validations , if they fails you can throw alerts.
    For application errors you use BPM.
    You can raise alerts if mapping, receiver determination etc.. fails in the integartion engine. You need to configure alert rules for this. You can go to RWB->Alert Configuration->Where did the error occur? choose integration engine and you can see different error categories and error codes which can be configured using alert rules. Refer this michal's weblog for configuring the same..
    /people/michal.krawczyk2/blog/2005/09/09/xi-alerts--step-by-step
    Currently alerts for Adapter framework errors are not supported.
    You can also raise an alerts from BPM for any mapping failures, send step system errors/application errors using fault messages (through exception branch).
    Refer this weblog for configuring an alert in the BPM
    /people/michal.krawczyk2/blog/2005/03/13/alerts-with-variables-from-the-messages-payload-xi--updated
    hope this helps..
    Regards
    Abhishek
    Edited by: Abhishek Agrahari on Jan 30, 2009 7:54 AM

  • Customized massage when OBIEE (OPMN) services are down.

    Hi,
    We have OBIEE 11g installed on Weblogic 10.3.3.0 and we have to have an outage message when either BI presentation Service or BI server goes down.
    Basically redirection to different URL or customized HTML page.
    I believe there is a customization which possible in weblogic.
    Can anyone direct me to it?
    Thanks!

    Neal,
    This is a great question and it can be handled in a few different ways.
    1.) You could modify the web.xml configuration file of the analytics web appliction for OBIEE. the web.xml file is located in teh /web/ folder for the main OracleBIServer. Remember, the analytics application (OBIEE Presentation Services) is just a Java application running in a container, so you can modify the deploy descriptor file to react to a 400 or 500 error. You get the 500 error when the Presentation Services component of OBIEE in OPMN is down. Here is a link on what you need to do for the web.xml file after you locate it (restart the BI Server and components afterwards. you may even need to redeploy the /analytics web application as well)
    Re: Customise Error pages in Weblogic
    2.) You could create a script that runs on the server at a short interval to run the opmnctl.bat|sh command and call the specific component to seek the single status of the presentation services comopnent. Parse the status and if it returs "Active" then all is good, if else, use your scripting skills to send a notification via email, etc.
    A combination of the two might be plausible as well, I'm not sure of the full requirements you have.
    Please mark this response as helpful or the right answer - Sunday is points awareness day. : )
    Cheers,
    Christian

  • Custom alert when certain emails arrive

    Can I set up a way to give me a distinct "ringtone" for an email address?

    No this option is not there in BlackBerry. But you can set dofferent alert for your different mail IDs.
    tanzim                                                                                  
    If your query is resolved then please click on “Accept as Solution”
    Click on the LIKE on the bottom right if the post deserves credit

  • How do generate custom alert when the performance value of the iis website connections reaches some value(SCOM)

    Currently am working on performance monitors and counters , like if the performance counters gets a value (say 10) i need to raise an alerts saying this value has reached

    Hi,
    Here are two article that should be helpful for you, please go through them for more details:
    System Center Operations Manager (SCOM) Best Practices Poster Rule and Monitor Targeting
    http://blogs.technet.com/b/danstolts/archive/2011/06/07/how-to-create-windows-server-2008-r2-guest-on-hyper-v-with-differencing-disk-and-sysprep-image.aspx
    Best Practices for Monitoring IIS Web Server
    http://myitforum.com/myitforumwp/2014/01/21/best-practices-for-monitoring-iis-web-server/
    Regards,
    Yan Li
    Regards, Yan Li

  • Dlsw using port channel

    I have 2 dlsw router at head quater office, named dlswA and dlswB.
    From branches router, dlswA is a primary peer and dlswB is a backup peer.
    Both dlswA and B have 2 fast ethernet interfaces.
    The current configuration of dlswA and dlswB are 1 port as IP port and other port as sna/bridge port.
    With this configuration the problem is when SNA port at dlswA problem, then dlsw circuit will have the problem, because dlsw peer from branches still connected to dlswA.
    if I configure 2 fast ethernet port become a port channel. And configure IP and bridge group at port channel interface (IP and SNA at the same interfaces), so when the port channel is down, then branches will connect to dlswB as a backup peer
    Are the port channel configuration will solve the problem ? How about the stability of this configuration?

    Thank Matthias for your reply.
    Both of head end routers are on the same vlan and the host is using same mac address.
    As far as i know if from branch have 2 active peer with cost setup, there will loops posibility because both head end routers are using ethernet with same vlan and same host mac address.
    I test the port channel within my LAB using netbios, seem works as expected. when single port at port channel down, branch circuit still remain at dlswA router, when all port channel member down, the branch peering move to dlswB.
    Here are the config:
    hostname dlswA
    dlsw local-peer peer-id 192.168.255.1 promiscuous
    dlsw bridge-group 1
    interface Port-channel10
    ip address 192.168.255.1 255.255.255.248
    bridge-group 1
    interface FastEthernet0/0
    no ip address
    duplex auto
    speed auto
    channel-group 10
    interface FastEthernet0/1
    no ip address
    duplex auto
    speed auto
    channel-group 10
    end
    hostname dlswB
    dlsw local-peer peer-id 192.168.255.10 promiscuous
    dlsw bridge-group 1
    interface Port-channel11
    ip address 192.168.255.10 255.255.255.248
    bridge-group 1
    interface FastEthernet0/0
    no ip address
    duplex auto
    speed auto
    channel-group 11
    interface FastEthernet0/1
    no ip address
    duplex auto
    speed auto
    channel-group 11
    end
    Hostname Branch
    dlsw local-peer peer-id 172.16.0.1
    dlsw remote-peer 0 tcp 192.168.255.1
    dlsw remote-peer 0 tcp 192.168.255.10 backup-peer 192.168.255.1 linger 0
    dlsw bridge-group 1
    interface Loopback0
    ip address 172.16.0.1 255.255.255.255
    interface FastEthernet0/1
    no ip address
    duplex auto
    speed auto
    bridge-group 1
    But I'm not sure this scenario will work for sna application like ATM machine, and SNA SAA gateway.
    Please kindly advised, Is there any alternatif ?

  • Total speed for port-channel when config speed 1000 in nexus5548?

    hi ,everyone.
    now i connect cisco 6509 and nexus 5548up using two 1000M link,and i want to binding two link as port-channel,
    because 5548up port is 10GE ,cisco 6509 port is 1GE,i config speed 1000 in the nexus5548 ethernet port ,and i find
    that speed 1000 commade auto config in interface port-channel,so i want to know the total speed in this port-channel
    is 1000M or 2000M when the port-channel speed config as 1000?i appreciate for your help!!
    the topology like this:
                  1000M
    6509      port-channel speed 1000M    nexus5548UP
                  1000M

    hi again
    The speed of the links and portchannel is 1000M but the bandwith of the portchannel is 2000M

  • ACE - Port-channel High Availability

    We have configured two ACEs with high Availability. ACEs link with our cores, switches cat6500, through a port-channel, ACE’s ports G1/1 and G1/2. High availability works fine if some vlan down but it doesn’t work if an interface down, only if both interfaces get down because then, all vlans of the channel port get down two.
    If possible get an interface port-channel high availability?
    Thanks for your help in advance.

    Thanks for your answer. I have two Cat6500, no VSS possibility. I have two ACEs so each one has configured a port-channel with one Cat6500 (two ports). It works fine. Any problem with that. My issue is when one port-channel of both port is down, failover doesn’t works then, only if both ports are down or vlans are down. I think high availability is only possible in vlan interfaces, not in physical interfaces.
    Regards my friend.

  • Requirement for Alert when outbound idocs are failing

    SAP A -
    IDOCS -
    >  SAP B
    We currently have a SAP A system sending outbound idocs to SAP B system via ALE. The current issue is when SAP B system is down. The outbound idocs being sent from SAP A system fail.
    We want to get a alert when the System B is down.
    What are the options available in SAP to achieve this requirement.
    Thanks in advance for any inputs that will be provided.
    Regards,
    Chandra Kumar

    Dear Chandra,
    The logical solution to the problem is as below,
    You need to have a Function module which checks the RFC connections between two systems before sending idoc. If the connection is found OK then the idoc should be send else a Alert message should be raised u201CSystem B is down, idoc can not be processedu201D
    Please let me know if this solution helped in resolving your query.
    Regards
    Dinesh

  • How to configure alert when sender CChannel failes

    Hi PI Gurus,
    Is there is any way to get an alert when a sender channel fails (reason connection time out etc.).
    We have configured alerts for other scenarios when mapping is failing. How to handle the other situation.
    Regards,
    Krishna Chauhan

    Hi,
    Please check below urls.
    http://wiki.sdn.sap.com/wiki/display/XI/Alert%2bConfiguration%2bin%2bXI?bc=true
    ALRTCATDEF table SALRTCATUS
    http://help.sap.com/saphelp_nw04/Helpdata/EN/8a/3e2d4105f8d92be10000000a1550b0/frameset.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/96/f1033c128f4a7de10000000a114084/frameset.htm
    Thanks
    Ravi

Maybe you are looking for