Hello,
I need help by deploying my workspace to the deployment(target)computer. That is what I have done:
- i create a workspace, in this workspace are different sequence files and the vi´s which i have created.
- then i use the deployment tool (teststand) and deploy the workspace to a directory in the network.
- after that i copy the modified SequentialModel.seq to the target maschine.
- now if i want start the sequence file an error occured. Teststand can`t start my vi´s because it can`t find files like LabVIEW Test - Sequence Context, TestStand - Set Property Value (Boolean Array). Choosing the path of the file in the search directory doesn`t help.
Maybe i have made an error with the deployment tool?! How is the right way to deploy in a network without using an installer. Iám using teststand 3.0.
thankyou
Schwede

Hi Schwede
If you want to deploy your Sequence File and the Processmodell you have to copy first your original Processmodell from the NI folder to the user folder.
Than open the deploy-tool and load your workspacefile. Mark the point "deploy files in Teststand user directories" and define the image path. Don't mark the "create installer" field.
You will get and image folder with several subfolder.
In the target subfolder you can find your sequencefile. In the Teststand subfolder you can find your customized Processmodell or Operator Interfaces. Attention, please use relative paths when you create your workspacefile.
hope this helps
Manuel Wielander
National Instruments

Similar Messages

  • Original files are missing after re-installation (Test-sequence context.ctl)

    Hello,
    after upgrading from LV2010 to LV2013 my VIa are missing these files for eample
    Labview Test-Sequence Context.ctl
    TestStand GetPropertyValue (String)
    I also reinstalled Teststand.
    How can i get the files back? I fdont know if they were a part of Labview or Teststand-installation.
    Thanks for help
    TM
    Solved!
    Go to Solution.

    Hey TM,
    It soundls like the missing VIs are part of TestStand.
    "TestStand GetPropertyValue (String)" is something TestStand provides, "Labview Test-Sequence Context.ctl" is also a TestStand component if I remember correctly.
    It is important that LabVIEW is installed first. After, you can run the installer of TestStand. It is important that support for LabVIEW  is selected in the installer.
    Regards, Stephan

  • Deploy teststand with labview ui

    Hi,
    I'm using teststand now since 9 months and now I have to distribute my application to a testing machine. I have some questions about this process. But first I discribe my application:
    I have a labview ui, which has 3 main tasks:
    1.) Start selected teststand sequences for automatic testing.
    2.) Give operator the possibility to manually control the testing environment (purely written in labview)
    3.) Run continous data aquisition, which provides data for teststand and manual testing.
    Sharing data between labview and teststand is done mainly via global variables (e.g. reference to tdms file). Because of 1.) and 2.) above teststand and labview share a lot of VIs for communicating with the testing environment.
    OK, now my questions:
    I'm searching for the best way to deploy this application via an installer. I know, that there is a teststand deployment tool (which I havn't used, yet) and I know how to build installers with the labview project manager.
    1.) What about sharing of VIs and global variables between my teststand sequences and my generated labview exe? When I place my sequences in the workspace file for the teststand deployment tool, all referenced VIs are included in teststand. But Some of these VIs are also included in my generated labview ui. Will this generate a conflict?
    2.) I was thinking about to create a teststand deployment without a workspace file. The sequences and all required VIs would be placed in the generated labview ui instead. Will the teststand sequences find the VIs inside of the ui exe?
    3.) What about required drivers (e.g. daq-mx)? Should I create a labview installer of my ui with the required drives and install this, then create a teststand installer (perhaps including the ui, too) and install this, too?
    Thanks for any help in advance.
    Marc
    CLD

    Hi,
    I would recommend the Deployment Tool for your TestStand and OI. I would also keep your Test Sequence files seperate from your TestStand Engine amd UI deployment.
    [1.) What about sharing of VIs and global variables between my teststand sequences and my generated labview exe? When I place my sequences in the workspace file for the teststand deployment tool, all referenced VIs are included in teststand. But Some of these VIs are also included in my generated labview ui. Will this generate a conflict?}
    This is going to cause you a problem because LabVIEW doesn't like / will not load the same VI into memory from two different locations.
    The Deployment Tool will probably object as well therefore you will not beable to create a deployment package.
    The Deployment Tool will place all the VIs that are called directly from TestStand Sequence Files as seperate VI's (not in a LLB) into the target folder. It will then create a support LLB containing all the subVI's used by the directly called VI's. If you have VI's that are called directly from TestStand and are also used as subVI's you will again have problems because the same VI can be loaded from two different locations. 
    2.) I was thinking about to create a teststand deployment without a workspace file. The sequences and all required VIs would be placed in the generated labview ui instead. Will the teststand sequences find the VIs inside of the ui exe?
    No Teststand will not beable to find your VI's in the EXE. If you need to use the same VI's in both your OI and TestStand sequence file then create a DLL.
    But I would recommend you keep the OI code seperate from your Test Code.
    3.) What about required drivers (e.g. daq-mx)? Should I create a labview installer of my ui with the required drives and install this, then create a teststand installer (perhaps including the ui, too) and install this, too?
    Install your drivers first. The IO should be installed as part of the TestStand deployment as this will register the various components correctly.
    Regards
    Ray Farmer
    Message Edited by Ray Farmer on 08-06-2008 01:02 PM
    Regards
    Ray Farmer

  • Deploy teststand system Labview instrument drivers

    I'm trying to deploy a teststand application but I have an error with some Labview VI's.
    I'm using some VI's to control an Agilent 34401A, so Labview instruments library that
    is in the default package was used. The error says that Labiew Could no open the following VIs...
    I don't want to install the Labview development system on the target machine, so I don't know
    how to fix this problem.
    I tried to copy the library to a different location an removing the VIs that are not wired (VI Tree.vi),
    but I have the same error. (On the sequence was changed the path to the new VI location).
    Thanks
    Marcos

    Marcos,
     You can execute VIs using the LabVIEW Runtime Engine, but all of the source VIs must be processed to collect their required dependencies and insure they are compiled in the current version of LabVIEW.  The Deployment Utility process VIs from your sequences automatically.  The TestStand Reference Manual has a chapter on deploying TestStand systems that should help you get started.
    -Rick Francis

  • TS Sequence Context and Invoke Node problems

    I have a Vi that was developed in 7.1 and TS 3.1.  I inherited this design from a past developer.  The Invoke node works fine when loaded with LV 7.1 but not when I load the Vi with LV 8.2.1.  I have gone through everything I can think of to correct the problem.  Help would be appreciated. [email protected]  (contact address to let me know you posted or you can do it directly.  Thanks in advance.
    Attachments:
    TestStand - Dist LabVIEW Test - Sequence Context.ctl ‏6 KB
    TestStand - Get Property Value (Number).vi ‏42 KB

    I just loaded this vi in 7.1, 8.2 and 8.5 and it works just fine for me. Although my TS version is 4.0. Can you expalin what you mean by it doe not work in 8.2. Does it load correctly? Have you reinstalled teststand into LV 8.2 so that you can open the TS pallette in LV 8.2? Are you running this inside of a sequence and passing the sequence context to it. It will not run correctly if a sequnce context is not passed to it from TS.
    Also you should post this in the teststand forum and not the LV forum
    Joe.
    "NOTHING IS EVER EASY"

  • How much modification can be made to VIs without changing the test sequence?

    Hi,
    Stupid question (likely). 
    If I have a TestStand (4.1) test sequence and within I am calling various Labview VIs (8.6), can I modify the VI in a small way without affecting the teststand sequence?
    I realise if I change the connectors in anyway this will definitely require modification (or reloading) of the VI in teststand but what if I change something more internal, say change a for loop to while loop or add cases etc.??
    Basically I want to add some features to a VI but I don't want to have to go through over 100 sequence files, reload the VIs (although this can be done programmatically), save the files as new versions and then test them to make sure nothing has broken.
    Cheers.

    Hey WiMAX_Eng, thanks for posting your workaround. In a previous post you mentioned programatically relinking VIs. I assume that you followed the method discribed in the following articles. I wanted to post them here, so other members of the community can refer to them.
    Update VI Calls Dialog Box
    http://zone.ni.com/reference/en-XX/help/370052H-01/tsref/infotopics/db_update_vi_calls/
    How Can I Update All The VI Calls In A TestStand Sequence?
    http://digital.ni.com/public.nsf/allkb/D7CB87B8EE52E7978625758400762D2D?OpenDocument
    Thanks for your time,
    Best wishes,
    Rich R
    Applications Engineer
    National Instruments UK & Ireland

  • Mapping labview variables to teststand sequence context variables

    hi,
    how can i map variables from a vi (which is loaded in a test sequence in teststand) to teststand sequence context variables ?
    if my question is not clear enough then plz let me know.

    Sure I can help!
    You can use either method:
    Rodéric L
    Certified LabVIEW Architect

  • Passing teststand sequence context to labview

    hi,
    i want to access teststand sequence context from labview , can i know how to do that ?
    -giri

    Hi,
    This is cross posted here: http://forums.ni.com/t5/LabVIEW/mapping-labview-variables-to-teststand-sequence-context/td-p/1928835
    There is another method:
    Rodéric L
    Certified LabVIEW Architect

  • ActiveX Automation server error on deployed TestStand

    I'm trying to deploy TestSTand 2.0 + LabVIEW 6.1 on a PC under Win-2K.
    I created and deployed TS Engine and Operator Interface for LV.
    I try to deploy the "Auto.seq" test from the TS exemples.
    Of course, it works on my Development system.
    On the deployed system, I got an error : -18351; An error occurred reading an ActiveX Automation server type library.
    Step 'Read Database Option - Construct' of sequence 'Get Database Options' in 'SequentialModel.seq'
    Step 'Read Database Option - Read Options' of sequence 'Get Database Options' in 'SequentialModel.seq'
    After having ignored those 2 errors, the tests goes on normally and the report looks fine.
    I also get this error opening the database configuration:
    Step 'Read Database Option - Construct' of sequence 'Edit Database Options' in 'Database.seq'
    From answers already given for similar subjects, I've checked that TsDBOptions.dll is present and registered (done regsvr32...) on the PC.
    Can someone help ?
    Note: upgrading to more recent TS + LV versions is not a solution!

    Whether you are using database logging or not, you should not get an error like that when database options are loaded. From the kb's you specified it sounds like there was an issue with a COM/ActiveX server not getting registered in the past. Especially on machines in which TestStand was installed from a deployment rather than the main installer. Have you tried running the version switcher like the KB suggested? Did it succeed or give an error? If it gave an error what was the error? Could you perhaps try a fresh install of TestStand on a clean machine?
    -Doug

  • How to make labview real time understand sequence context

    Does anyone know how to make Labview RT to understand teststand sequence context? My sequence context is defined as "TS.SequenceContext" as the screenshot in the attachment.
    If we need to point a VI for this Sequence Context then which VI from teststand to use? and do we need to add this VI to the Labview Projectr Explorer in RT System to build the project?
    I'm using Labview 2009 and teststand 4.2.1.
    Thank you very much
    Solved!
    Go to Solution.
    Attachments:
    LVRT_TS.SequenceContext error.doc ‏132 KB

    LabVIEW RT does not support ActiveX which is required for TestStand.

  • Deploy TestStand System error

    When I try to run:
    Tools>>Deploy TestStand System>>Deployed Files>>LabVIEW Options>>Lock VI Diagrams
    I get the following error after I hit the Build key:
    Failure : linker.cpp line 2022
    LabVIEW version 6.1
    I suspect I need version 7.0?? Can anyone confirm this or let me know what I'm doing wrong?

    Rick,
    I've only got one simple vi in my sequence. I can run the build utility with no errors until I select the "Lock VI Diagrams" option. Note that my error code is now 1035 instead of 2022 like it was previously. The 2022 error was caused by not suppling password in the Lock VI Diagram box.
    Error Code:1035
    Could not process LabVIEW VIs. Fix any broken VIs before rebuilding. LabVIEW error:
    Invoke Node in TestStand - Dist Chg and Save VIs.vi->TestStand - Dist Build LLB Image.vi->TestStand - Build VI Distribution.vi->TestStand - Build VI Distribution AX Wrapper.vi->TestStand - Build VI Distribution AX Wrapper.vi.ProxyCaller
    Attachments:
    deployment_trial.zip ‏14 KB

  • TestStand v3.0 for multiple test sequence runs

    I am trying to setup the TestStandv3.0 so that it can execute multiple
    test sequences. Currently it executes one sequence and then rather
    than reporting the test results in an HTML format, it terminates and
    the entire tool quits execution. How do I fix this? I did not get
    this problem with TestStand v1.0.1 of of the box.

    Hi,
    It maybe that in the Station Options under the Execution Tab, for the
    On Run-Time Error control.
    Make sure the 'Immediately Goto Cleanup on Sequence Failure' is not
    checked.
    Regards
    Ray Farmer

  • Getting error While testing Web Service deployed Glassfish using Net beans.

    Hi,
    I created a web service in netbeans. I deployed it on glassfish server too.
    My web service contains one method which return type is Document. Here is my web service class code.
    @WebService(serviceName = "DocumentTest")
    @Stateless()
    public class DocumentTest {
         * This is a sample web service operation
        @WebMethod(operationName = "hello")
        public String hello(@WebParam(name = "name") String txt) {
            return "Hello " + txt + " !";
        @WebMethod
        public Document getDocument(){
            Document doc = null;
            return doc;
    }After Deployment when I m testing the web service I am getting follwoing error on Browser
    Error generating artifacts for the following WSDL http://localhost:8093/DocumentTest/DocumentTest?WSDL
    Possible causes can be invoking https when the application is not configured for securityI am just testing whether I can send Document object or not.
    Regards,
    Ajay Sharma
    Edited by: Ajay Sharma on Nov 27, 2012 12:37 PM
    Edited by: Ajay Sharma on Nov 29, 2012 2:16 PM

    Ajay Sharma wrote:
    I am just testing whether I can send Document object or not.An XML document? Wouldn't that be a really ridiculous web service?

  • Help:set up simple test sequence, operator selects particular test then teststand links to part of sequence file and performs test

    Hi,
    I am extremely new to TestStand, please see question below and offer advice.
    I want to set up a simple test sequence.
    I want a message to popup on screen that asks the operator which unit of 6(max 10) Units to test(i.e. there are say 6-10 box's to select from).
    Then the sequence goes to the particular part of the sequence and performs the test on which ever unit was selected.
    What is the best way to do this?
    Could i use message popups to do this?and if so what do i need to do link it to the correct part of the sequence file?
    Do message popups only allow 6 options to select from?
    Thanks,
    Solved!
    Go to Solution.

    Hi,
       You can do using message popup method. You can ask the user which unit want to execute by inserting message in message expression in message popup step settings.Something like below
    "Enter unit number to execute 
     1.  Unit1
     2.  Unit 2
     10. Unit 10"
    then check "Enable response text box" from options tab in step settings.When user enters unit number you can get the user entered value by inserting the below statement in post expression of message popup step settings
        Locals.String = Step.Result.Response 
        Note : String is a local variable to be defined.
    Convert that string in to number and send that output to switch expression there by you can use a sequence call step to call sequence whichever to be executed. (I hope your each unit will be seperate sequence file)
    I hope these resolves your problem. If you don't understand let me know so that I can develop a small example and send it to.
    Cheers,
    krishna 

  • Changer la sequence model de Teststand avec Labview

    Bonjour,
    Je lance une séquence avec LabVIEW mais il faudra que j'utilise une autre SequenceModel. Je voudrai changer la SequenceModel utilisé par Teststand avec LabVIEW. J'ai commencé par faire ça :
    Mais rien ne se passe.
    Merci.
    Résolu !
    Accéder à la solution.

    Merci mais j'ai trouvé la solution :
    Je charge la séquence de test puis je charge la SequentialModel choisi.
    Voilà merci pour ton aide.

Maybe you are looking for

  • Can't change the master page after upgrading to SharePoint 2013.

    After upgrading our farm to SharePoint 2013 we are having trouble changing the master page for sites that don't have sub-sites. We are still using the v4 UI version, and that appears to be what is causing the problem. The error we get when going to /

  • Closing an RTP stream

    Hi, I have written a simple application to stream audio. The first stream works, the recipient plays the file. However, when I go to stream another the recipient cannot open the local data port, because the previous socket is still bound. So my quest

  • How to write notes in a pdf file in iBooks

    Hi, I want to be able to work with pdf files (scientific journals) in a way that I can insert notes by keyboard as I am reading the article, also highlighting text would be useful. I notice that this is possible with books i iBooks but I can not make

  • Index not being used in Select statement

    Friends I have the following SQL statement: SELECT a.acct, a.date_field, UPPER(b.feegroup) feegrp, SUM (a.fee1) fee1, SUM (a.fee2) fee2, SUM (a.fee3) fee3 FROM table1 a, table2 b WHERE 1 = 1 AND a.fee_id = b.fee_id GROUP BY a.acct, a.date_field, b.fe

  • Clarification on migration from iMac G5 running 10.4.11 to new intel iMac

    Hello, Although a lot of you have already posted on this subject, I just wanted to get a clarification, please. I just got a new intel iMac and I would like to transfer all my files from my iMac G5 (10.4.11). Should I just use the Migration Assistant