Deploy TestStand System error

When I try to run:
Tools>>Deploy TestStand System>>Deployed Files>>LabVIEW Options>>Lock VI Diagrams
I get the following error after I hit the Build key:
Failure : linker.cpp line 2022
LabVIEW version 6.1
I suspect I need version 7.0?? Can anyone confirm this or let me know what I'm doing wrong?

Rick,
I've only got one simple vi in my sequence. I can run the build utility with no errors until I select the "Lock VI Diagrams" option. Note that my error code is now 1035 instead of 2022 like it was previously. The 2022 error was caused by not suppling password in the Lock VI Diagram box.
Error Code:1035
Could not process LabVIEW VIs. Fix any broken VIs before rebuilding. LabVIEW error:
Invoke Node in TestStand - Dist Chg and Save VIs.vi->TestStand - Dist Build LLB Image.vi->TestStand - Build VI Distribution.vi->TestStand - Build VI Distribution AX Wrapper.vi->TestStand - Build VI Distribution AX Wrapper.vi.ProxyCaller
Attachments:
deployment_trial.zip ‏14 KB

Similar Messages

  • Deploy teststand system Labview instrument drivers

    I'm trying to deploy a teststand application but I have an error with some Labview VI's.
    I'm using some VI's to control an Agilent 34401A, so Labview instruments library that
    is in the default package was used. The error says that Labiew Could no open the following VIs...
    I don't want to install the Labview development system on the target machine, so I don't know
    how to fix this problem.
    I tried to copy the library to a different location an removing the VIs that are not wired (VI Tree.vi),
    but I have the same error. (On the sequence was changed the path to the new VI location).
    Thanks
    Marcos

    Marcos,
     You can execute VIs using the LabVIEW Runtime Engine, but all of the source VIs must be processed to collect their required dependencies and insure they are compiled in the current version of LabVIEW.  The Deployment Utility process VIs from your sequences automatically.  The TestStand Reference Manual has a chapter on deploying TestStand systems that should help you get started.
    -Rick Francis

  • Deploy Teststand system hangs

    When I start the Deploy TestStand system dialog and start a build it gets this far
    Saving File:
    C:\Documents and Settings\cglidden\My Documents\TestStand Deployment\DCT 3p1\Installer\DCTwPick.tsd
    Processing Workspace...
    Done processing workspace file
    Beginning build process, please wait.
    8:18 AM
    and then hangs.  I am using TestStand 3.1 on a Win 2K machine and am deploying because the sequence uses LabVIEW 7.0 VIs.  I had a problem before with the utility hanging later in the process but the same fixes do not work here. There is no hidden dialog box stopping  things either.
    Any ideas?
    Thanks,
    Chas

    Hi Chas,
    Are you able to create a simple sequence with just a
    message box and deploy that?
    Thanks,
    Terry S.
    Staff Software Engineer
    National Instruments

  • What is the difference between Deploy TestStand system(3.1) and Run Engine Installation wizard(1.0) in Tools menu

    Hi,
       In TestStand

    If you want to run a TS script that calls VIs on a Runtime engine only system you have to use the Deploy TestStand utility to do that. Since a Runtime Engine only system does not have vi.lib you must search all the .seq for VI calls and then traverse all the SubVis to find all the calls to VIs in vi.lib. The Deploy TestStand does that for you. It moves all the VIs and SubVIs to a SupportVI directory and mass compiles them. Once all VIs are within the same directory the runtime engine can find them.
    Note: This is a very nasty poorly written tool. I had a deploy that would take about 6 hours to complete. I wrote my own that takes about 4 minutes to complete.

  • Deploy TS system without uninstall

    How do I set "Deploy TS system" to just update a previous installation done with Deploy utility? Is it just to call it a different name under "Installer options/Advanced options/Keywords, Version, Subject or product code"? I have looked in the manual and cant find information about these fields.
    Many thanks

    Hello Dan!
    I believe the information you are requesting can be found in the TestStand help and in particular you should look at the following text:
    Quote:
    "Advanced Installer Options Dialog Box
    To launch the Advanced Installer Options dialog box, launch the Deploy TestStand System dialog box and click Advanced Options on the Installer Options tab.
    The Advanced Installer Options dialog box contains the following options:
    Manufacturer—Specifies the name of the company, which appears in the Currently Installed Programs list of the Add or Remove Programs dialog box in Windows. This option corresponds to the [Manufacturer] Microsoft Installer (MSI) property.
    Version—Specifies the current software version number. The installer uses this number to check for a current installation and to check for upgrades. You must increment the version number to create versions of the installer that are capable of overwriting previous installers. The version corresponds to the [ProductVersion] Microsoft Installer (MSI) property.  Note  This control is disabled if the Auto Increment option is enabled.
    Auto Increment—Specifies that the version is automatically increased when an installer is built. When you select this option, the Version control is disabled.  Note  You must save your deployment before closing the Deploy TestStand System dialog box to retain the new version number. 
    Upgrade Code—Displays a string that uniquely identifies a related set of installers in Windows. Only one system, with a specific upgrade code, can be installed on a computer at a given time. An installer that has the same upgrade code and a higher version updates an older installation. The upgrade code corresponds to the [UpgradeCode] Microsoft Installer (MSI) property."
    So the last one is the method I believe you should use!
    Regards,
    Jimmie A.
    Applications Engineer, National Instruments 
    Regards,
    Jimmie Adolph
    Systems Engineer Manager, National Instruments Northern Region
    Bring Me The Horizon - Sempiternal

  • Deployment error:Error Code:-17500, Unknown System Error in TestStand - Read Seq Files in Workspace.vi-

    Help!
    When trying to deploy a test system i got the following error:
    Error Code:-17500
    Unknown System Error in TestStand - Read Seq Files in Workspace.vi->TestStand - Find Dependent Files.vi->TestStand - Add File and Dependent Files.vi->TestStand - Add All TestStand User Files to File Info Array.vi->TestStand - Update File Info.vi->TestStand - Distribution Wizard GUI.vi->TestStand - Deployment Utility Splash Screen.vi
    I then tried to re-deploy previously successfully deployed systems - same error. (I have done nothing to my teststand setup/installation/engine or deployment files since the last successful deployment)
    I removed teststand & then re-installed it - i still got the same error. These files it is searching for do not exist on my pc.
    Any ideas what has gone wrong/how to fix it?
    cheers
    Fi

    I've just had exactly the same problem and after posting a message, have been forwarded to this thread. Luckily it looks as though we've found a solution, or a cause of the problem. One of my work colleagues (SercoSteve on discussion forums) suggested removing the Teststand 3.1\cfg directory, and replacing it with a default one from another machine, and this seems to have done the trick and made the deployment wizard be able to analyse the files and build. We are editing files in cfg so I've now got the task of replacing each file in this directory one by one to find which is causing the problem.
    I'll add another post when I find out which one it is.
    David Clark
    CLA | CTA
    CLA Design Ltd
    Hampshire, England

  • ActiveX Automation server error on deployed TestStand

    I'm trying to deploy TestSTand 2.0 + LabVIEW 6.1 on a PC under Win-2K.
    I created and deployed TS Engine and Operator Interface for LV.
    I try to deploy the "Auto.seq" test from the TS exemples.
    Of course, it works on my Development system.
    On the deployed system, I got an error : -18351; An error occurred reading an ActiveX Automation server type library.
    Step 'Read Database Option - Construct' of sequence 'Get Database Options' in 'SequentialModel.seq'
    Step 'Read Database Option - Read Options' of sequence 'Get Database Options' in 'SequentialModel.seq'
    After having ignored those 2 errors, the tests goes on normally and the report looks fine.
    I also get this error opening the database configuration:
    Step 'Read Database Option - Construct' of sequence 'Edit Database Options' in 'Database.seq'
    From answers already given for similar subjects, I've checked that TsDBOptions.dll is present and registered (done regsvr32...) on the PC.
    Can someone help ?
    Note: upgrading to more recent TS + LV versions is not a solution!

    Whether you are using database logging or not, you should not get an error like that when database options are loaded. From the kb's you specified it sounds like there was an issue with a COM/ActiveX server not getting registered in the past. Especially on machines in which TestStand was installed from a deployment rather than the main installer. Have you tried running the version switcher like the KB suggested? Did it succeed or give an error? If it gave an error what was the error? Could you perhaps try a fresh install of TestStand on a clean machine?
    -Doug

  • I/o server shared variable not working in deployment system ( error no-1950679034 (0x8BBB0006) (Warning))

    Hello ,
             am using shared variable from opc client in labview when am run a exe file at development system its working fine but when am running it in deployment system its not working am using same configuration file in opc server at development and deployment system error -1950679034 (0x8BBB0006) (Warning)

    First Root cause needs to be identified before any actions.
    I would suggest first check if you can access the shared variable hosted in PC from RT using other ways like using SVE API (Logos and PS protocols, Datasocket etc..)
    Check if antivirus or firewall is playing...
    Check the same experiment with some other PC if you can.
    You can also try creating another Shared Variable in RT and binding the same to the PC and try to access it...
    Since you have did all the reinstallations already
    Best Regards,
    Vijay.

  • NiRFSA_Rea​dPowerSpec​trumF64 function call in TestStand 4.5.1 cause system error

    I am using TestStand with niRFSA.dll to call the function niRFSA_ReadPowerSpectrumF64. This function will make the NI RFSA takes a spectrum sweep and return an array of amplitudes, as well as a structure that contains the frequencies information. My teststand sequence file is attached. The sequence editor will execute this function call, and actually retrieve correct data from the RFSA, I can see all the data in the Locals variables. The data are correct. However, the sequence editor also throws out system error, with no further details.
    See the error window also attached.
    Once in a while, the sequence editor will work just fine, executing the same function call without throwing out error, this is less than 10% of the time.
    I am using this on Windows 7.
    Let me know if you have any insight.
    Attachments:
    RFSA Sequence.seq ‏7 KB
    Capture.JPG ‏33 KB

    Hi Doug:
    Yes this is what I suspected also. Since the container type was a TS custom type I created to accept the C struct from the instrument. But when the data come back from the dll is a C struct, and there lays the conflict, I think its the packaging layer semantics have some conflict, even though each of the element in the C struct matches the TS type definitions, as I received all that data correctly in TS.
    Thanks,
    Juswanto

  • Trouble deploying TestStand

    Hi,
    I have tried many suggestions and configurations but I still cant get my deployed TestStand to run in other PC. I kept getting "Unable to launch the 'LabVIEW .Application' ActiveX automation server. TestStand cannot find a LabVIEW Development System installed in this computer." My test sequence also uses custom process model. Below are the things that I have done:
    1. Configured the LabVIEW adapter to use RTE and enable "Always Run VI in LabVIEW RTE" in the LabVIEW Advanced Settings under Module tab.
    2. Added configuration .ini files that will be used, including TestExec.ini and TestStandModelModelOptions.ini in workspace.
    3. Enable "Install TestStand Engine" and leave Engine Options/ Drivers and Components as default.
    Below are my questions:
    1. Since I am using custom process model, where should I save this .seq in?Is it in my working directory or TestStand components folder? Reason why I am asking this is because I tried both ways, the latter gave me
    "Warning: This problem will cause an error when building a deployable image or an installer. The following file(s) were not found:
    rfid_read_write.seq in step 'Reset Test Sequence', sequence 'MainSequence', sequence file 'C:\Program Files (x86)\National Instruments\TestStand 4.2.1\Components\Models\TestStandModels\SequentialModel_RFID.seq'"
    Obviously rfid_read_write.seq has already been included and present.
    2. Should I also include this custom process model .seq file in the workspace/deployment?
    3. How to solve the unable to launch LabVIEW.Application issue?
    Thanks.

    Hi, it looks like the app has trouble starting up:
    05/01/17 10:21:47 - ERROR: ID90506: NOT Deployed. ERROR returned from deploy service :
    com.inqmy.services.deploy.container.DeploymentException: Can't init application carmodeller. com.inqmy.services.servlets_jsp.server.WebApplicationException: ID17110: Error in starting application carmodeller.java.lang.NullPointerException
    Did you have any errors on the compile of the code?
    You also want to check if the app is deployed (if so you may want to remove it before re-deploying it)

  • File System error while restoring a backup from analysis server to another

    Hi
    I have restored an analysis database backup to from server 1  (sql server 2008) to server 2(sql 2008) and its working fine 
    and now am trying to restore another database from analysis server server 3 (sql 2005) to  server 2 (sql 2008 )but its giving error that 
    File System error occured while opening the file G:\ProgramFiles\MSAS10.MSSQLSERVER\OLAP\Backup\Workordermodule.0.db\WomDW1.7.00 ..etc

    Hi Maverick,
    According to your description, you are experiencing the error when restoring the SSAS 2005 database on SSAS 2008 server, right?
    In your scenario, how do you backup your SSAS 2005 database? Please ensure that you backup and restore steps are correct. Here is a blog which describe how to migrate a cube in SQL Server Analysis Services 2005 to SQL Server Analysis Services 2008 step by
    step, please refer to the link below.
    http://blogs.technet.com/b/mdegre/archive/2010/03/31/migrating-a-cube-in-sql-server-analysis-services-2005-to-sql-server-analysis-services-2008.aspx
    Besides, you can import SQL 2005 AS database in SQL 2008 BIDS Project. Then fix AMO warnings and deploy that database on SQL 2008 Server.
    http://technet.microsoft.com/en-in/library/ms365361(v=sql.100).aspx
    Regards,
    Charlie Liao
    TechNet Community Support

  • Bulk Insert Task Cannot bulk load because the file could not be opened.operating system error error code 3(The system cannot find the path specified.)

    Following error i am getting after i chnaged the Path in Config File from
    \\vs01\d$\\Deployment\Files\temp.txt
    to
    C:\Deployment\Files\temp.txt
    [Bulk Insert Task] Error: An error occurred with the following error message: "Cannot bulk load because the file "C:\Deployment\Files\temp.txt" could not be opened. Operating system error code 3(The system cannot find the path specified.).". 

    I think i know whats going on. The Bulk Insert task runs by executing sql command (bulk insert) internally from the target sql server to load the file. This means that the SQL Server Agent of the target sql server should have permissions on the file you trying to load. This also means that you need to use UNC path instead to specify the file path (if the target server in on different machine)
    Also from BOL (see section Usage Considerations - last bullet point)
    http://msdn.microsoft.com/en-us/library/ms141239.aspx
    * Only members of the sysadmin fixed server role can run a package that contains a Bulk Insert task.
    Make sure you take care of this as well.
    HTH
    ~Mukti
    Mukti

  • HFM EPMA application deployment aborted with error Object reference not set

    HFM EPMA application deployment aborted with error Object reference not set to an instance of an object when trying to validate/deploy any HFM application in EPMA. This has started happending after we have deleted a Dimension in one of HFM applications. The deleted dimension is a shared dimension.
    We are facing this issue in a distributed environment with version 11.1.2.1. This applications are built here newly.
    Following is the error log entry
    16] ERROR Object reference not set to an instance of an object.
    at Hyperion.DimensionServer.CompareCriteria.<>c__DisplayClass5.<GetMemberClassProperties>b__4(Dimension dim)
    at Hyperion.DimensionServer.Library.IterateDimensions(Action`1 action)
    at Hyperion.DimensionServer.CompareCriteria.GetMemberClassProperties(ApplicationClass appClass, DimensionClass dimClass, MemberClass mbrClass)
    at Hyperion.DimensionServer.CompareCriteria.GetCommonMemberClassProperties(RelationshipMember fromMember, RelationshipMember toMember, ApplicationClass fromAppClass, ApplicationClass toAppClass)
    at Hyperion.DimensionServer.CompareMemberEvaluator.CompareProperties(RelationshipMember fromMember, RelationshipMember toMember, ApplicationClass fromAppClass, ApplicationClass toAppClass, List`1 propertyDifferences)
    at Hyperion.DimensionServer.CompareMemberEvaluator.Compare(RelationshipMember sourceMember, Application sourceApp, Application targetApp, Boolean firstPass, Int32 level, Boolean continueCheckingAfterDifferences)
    at Hyperion.DimensionServer.CompareMemberEvaluator.Compare(List`1 sourceTopMembers, List`1 targetTopMembers, Application sourceApp, Application targetApp, Boolean firstPass, Boolean continueCheckingAfterDifferences)
    at Hyperion.DimensionServer.CompareMemberEvaluator.Execute(List`1 fromTopMembers, List`1 toTopMembers, Dimension fromDimension, Dimension toDimension, Boolean continueCheckingAfterDifferences)
    at Hyperion.DimensionServer.CompareDimensionEvaluator.Execute(Dimension fromDimension, Dimension toDimension, ApplicationClass fromAppClass, ApplicationClass toAppClass)
    at Hyperion.DimensionServer.CompareEngine.CompareDimensions(Dimension fromDimension, Dimension toDimension)
    at Hyperion.DimensionServer.CompareEngine.StartCompare()
    at Hyperion.DimensionServer.Validations.HFMApplicationValidation.CheckStaticDimension(Library snapShot, Dimension dim, Application oldApp, String[] skipProperties)
    at Hyperion.DimensionServer.Validations.HFMApplicationValidation.CheckStaticDimensions(Application baselineApp)
    at Hyperion.DimensionServer.Validations.ApplicationValidation.ValidateAgainstBaseline()
    at Hyperion.DimensionServer.Validations.HFMApplicationValidation.InternalValidate()
    at Hyperion.DimensionServer.Validations.ApplicationValidation.Validate()
    at Hyperion.DimensionServer.Validations.ApplicationValidation.<ValidateAsync>b__0()System.NullReferenceException: Object reference not set to an instance of an object.
    at Hyperion.DimensionServer.CompareCriteria.<>c__DisplayClass5.<GetMemberClassProperties>b__4(Dimension dim)
    at Hyperion.DimensionServer.Library.IterateDimensions(Action`1 action)
    at Hyperion.DimensionServer.CompareCriteria.GetMemberClassProperties(ApplicationClass appClass, DimensionClass dimClass, MemberClass mbrClass)
    at Hyperion.DimensionServer.CompareCriteria.GetCommonMemberClassProperties(RelationshipMember fromMember, RelationshipMember toMember, ApplicationClass fromAppClass, ApplicationClass toAppClass)
    at Hyperion.DimensionServer.CompareMemberEvaluator.CompareProperties(RelationshipMember fromMember, RelationshipMember toMember, ApplicationClass fromAppClass, ApplicationClass toAppClass, List`1 propertyDifferences)
    at Hyperion.DimensionServer.CompareMemberEvaluator.Compare(RelationshipMember sourceMember, Application sourceApp, Application targetApp, Boolean firstPass, Int32 level, Boolean continueCheckingAfterDifferences)
    at Hyperion.DimensionServer.CompareMemberEvaluator.Compare(List`1 sourceTopMembers, List`1 targetTopMembers, Application sourceApp, Application targetApp, Boolean firstPass, Boolean continueCheckingAfterDifferences)
    at Hyperion.DimensionServer.CompareMemberEvaluator.Execute(List`1 fromTopMembers, List`1 toTopMembers, Dimension fromDimension, Dimension toDimension, Boolean continueCheckingAfterDifferences)
    at Hyperion.DimensionServer.CompareDimensionEvalua
    There was a bug in earlier releases for deleting dimensions with children, making the children orphans.
    Heard from release notes that it has been fixed, but we are seeing this issue in 11.1.2.1 again.
    Please help us out in resolving this error.

    Hi,
    I always ask this first, have you installed all the planning and epma patches as there have been many issues addressed in 9.3.1
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • Is it possible to debug VIs being run on a deployed TS System?

    I have a VI that is intermittently wandering off into left field to look at all the dandelions. It's being run from TestStand (base deployment engine) on a deployed system. I'd like to debug it from my development box.
    Is there a way, perhaps along the same lines as the LV App Builder 'Enable debugging' option, to hook my development system into the VI as it's executing on the deployed system?
    I've dug around a bit, and keep finding the notes on App Builder, but haven't seen a way to do it through TS.
    Thanks for any help
    Tom McManus
    Message Edited by Thomas McManus on 07-13-2009 02:11 PM

    Hi Tom,
    You will not be able to remotely access a VI that has been called by TestStand.   You can, however, create a debuggable DLL (with the problematic VI), and remotely connect to that.  To do this, you will need to rebuild your VI as a shared library and enable debugging on the Advanced Tab of the Application Builder.  Once this is complete, you will need to change the step type to C/C++ DLL.  You will also now need to manually configure your parameters for this step.  Lastly, you will need to re-deploy your system.  Once the the TestStand Application is running, you can go to Operate»Debug Application or Shared Library from the LabVIEW Getting Started Window on the development machine.  From here you can access the shared library that is running.
    The other options you have, as I mentioned, are to bring the VI over to the development machine and debug there, activate the full version of TestStand on the deployment computer, or purchase a debug-deployment license.  I hope this was helpful!
    Cheers,
    Kelly R.
    Applications Engineer
    National Instruments

  • Install BI Java Add-in for ABAP system error

    Dear all:
    I want to install Java Add-in for my ABAP system. My ABAP is SR3
    Nw04s. During the CI install for Java Add-in steps: install software
    unites, i got one error like this:
    Error: Aborted: development
    component 'caf/eu/gp/model/eap'/'sap.com'
    Mar 17, 2009 2:28:29 PM Error: Aborted: development
    component 'caf/eu/gp/model/eap'/'sap.com'/'MAIN_APL70VAL_C'/'1497904'/'3', grouped by software component 'SAP-
    EU'/'sap.com'/'MAIN_APL70VAL_C'/'1000.7.00.14.0.20071210153525''/'3':
    Caught exception during application deployment from SAP J2EE Engine's
    deploy API:
    com.sap.engine.deploy.manager.DeployManagerException: ERROR: NOT
    deployed. The Deploy Service returned the following error:
    com.sap.engine.services.rmi_p4.P4RuntimeException: Unexpected
    exception. java.net.SocketException: Connection reset
    Exception is:
    com.sap.engine.services.rmi_p4.P4RuntimeException: Unexpected exception. Nested exception is:
    java.net.SocketException: Connection reset
    at java.net.SocketInputStream.read(SocketInputStream.java:168)
    at com.sap.engine.services.rmi_p4.Connection.run
    (Connection.java:395)
    at java.lang.Thread.run(Thread.java:534)
    Can you give me some advice about this? Thanks.My JDK 1.4.2_19 for IA64.

    thanks

Maybe you are looking for

  • Win 8.1

    i am using  win 8.1 pro 64bit have failed to install the latest itunes software  instillation fails and stops is their a work around to my problem ??? regards ultan [email protected]

  • Upload Document in SAP DMS

    Hi SDNites, My requirement is to upload document in SAP DMS and this document we are receiving from an external system. Can you please let me know, 1. Is there any way I can provide a link in ECC SAP DMS for the documents which are stored in external

  • Rollover links don't work! iweb 08

    I've added a few rollover links to my text and they don't work when I upload the html to my non-mobileme server. I don't see any of my rollover picture sources in the code, but I don't know where or how to add them... Here is the code: <area href="ma

  • T440p wifi slow reconnect after sleep

    Hi, I have a T440p with the intel 7260AC wifi card. I recently upgraded my HDD to an SSD and did a clean windows 7 install. Now, when waking up from sleep, it alwas takes about a min before it reconnects to a wifi network. The reconnect used to be in

  • Getting started using iMac email

    Hi all, I have had my new iMac for a few weeks now and tried to use my Mac email account. The account is set up but when I sent myself a test email to my Yahoo email account, nothing happened. I sent another test email to another Yahoo email recipien