Do 15 times varying problem

hi all,
i have to pic the value of BET01.....BET15 from PA0589 according to PERNR where LGA01 = '4004'.
but i m not able to find the same. can anyone please halp me?
codes:
INFOTYPES: 0589.
DATA : BEGIN OF itab OCCURS 0 ,
       pernr LIKE pa0000-pernr ,                       "Personel no.
END OF itab .
DATA: BEGIN OF wagetypes,
      lga LIKE p0008-lga01,
      bet LIKE p0008-bet01,
  END OF wagetypes.
DATA : BEGIN OF it_itab OCCURS 0 ,
       pernr LIKE pa0000-pernr ,                       "Personel no.
       lga01 LIKE pa0589-lga01,
       bet01 LIKE pa0589-bet01,
       begda LIKE pa0589-begda ,                       "Lta start date
       lgart LIKE pa0015-lgart,                        "SUBTYPE OF INFOTYPE
       endda LIKE pa0015-endda ,                       "LTA Taken Date
       betrg LIKE pa0015-betrg,                        "LTA Amount
       zuord LIKE pa0015-zuord,                        "Assignment number
       ename LIKE pa0001-ename ,                       "Employee name
       ent_amt TYPE p DECIMALS 2,
       pending TYPE p DECIMALS 2,                      "Pending LTA amount
END OF it_itab .
START-OF-SELECTION.
  SELECT pernr INTO TABLE itab FROM pa0000 WHERE pernr IN pernr AND endda = '99991231' AND stat2 = '3'.
SORT itab BY pernr.
LOOP AT itab.
    rp_provide_from_last p0589 space pn-begda pn-endda.
    DO 15 TIMES VARYING wagetypes-lga
              FROM p0589-lga01
              NEXT p0589-lga02
       VARYING wagetypes-bet
              FROM p0589-bet01
              NEXT p0589-bet02.
      IF wagetypes-lga EQ '4004'.
        CLEAR wa_itab.
        MOVE p0589-pernr   TO wa_itab-pernr.
        MOVE p0589-begda   TO wa_itab-begda.
        MOVE wagetypes-lga TO wa_itab-lga01.
        MOVE wagetypes-bet TO wa_itab-bet01.
        APPEND wa_itab TO it_itab.
      ELSE.
        EXIT.
      ENDIF.
    ENDDO.
actually i need amount according to wage type '4004', and this wage type can maintain the value in any colom of table pa0589 as ita define as LGA01....to....LGA15 and respective amount maintained in BET01.....to.....BET15.
so please help me.
regards saurabh.
Edited by: saurabh srivastava on Jan 17, 2009 6:26 AM
Edited by: saurabh srivastava on Jan 17, 2009 6:40 AM
Edited by: saurabh srivastava on Jan 17, 2009 7:22 AM

Hi, Saurabh,
Following code may help you in this way here i am getting wage types 3003, 3004 and 3005.
get payroll.
  clear: p0001.
  rp_provide_from_last p0001 space payroll-evp-fpbeg payroll-evp-fpend.
  if ( payroll-evp-srtza = 'A' ).
    clear: orgeh_val .
    clear: wa_wpbp.
    loop at payroll-inter-wpbp into wa_wpbp ."where pernr = pernr.
      orgeh_val = wa_wpbp-orgeh.
    endloop.
    " Test on orgeh_val to get it's ist level node and 2nd  level node value
    if orgeh_val in department.
      objid_root_level = orgeh_val.
      objid_child_level = orgeh_val.
    else.
      perform get_2_dept using orgeh_val changing objid_root_level objid_child_level.
      objid_root_level = objid_root_level.
      objid_child_level = objid_child_level.
    endif.
    "-------------- End of getting ist level and 2nd level node value---------------------
    "----- Now get it's lgart value-------------->
    loop at payroll-inter-rt into wa_rt where   lgart =  '3003' or lgart =  '3004' or lgart = '3005'.
      if sy-subrc = 0.
        clear wa_it_final.
        "     BREAK-POINT.
        wa_it_final-objid = objid_root_level.
        wa_it_final-orgeh = objid_child_level.
        wa_it_final-tot_emp = 1.
        wa_it_final-amount = wa_rt-betrg.
        collect wa_it_final into it_final.
      endif.
    endloop.
    "BREAK-POINT.
  endif.
Please Reply if any Issue,
Kind Regards,
Faisal

Similar Messages

  • Very annoying Time Capsule problem - Not responding

    Hi,
    I have a really annoying problem with my Time Capsule and/or network setup. Although I did huge research on this matter, I still have no solution for the problem, nor any more ideas how to get rid of this misbehavior.
    First of all, I would like to introduce a draft of my current network setup with all included clients, switches and routers:
    As you can see, I have 3 Apple computers, 1 Windows 7 client, a Canon MX895 network printer, the said time capsule and an AVM Fritz!Box WLAN Router for internet access.
    Both MacBooks are WiFi connected to the Fritz! which serves as the central WLAN accesspoint with simultaneous 2.4/5 GHz. The interconnection between the Fritz! and the Time Capsule is a wired 100MBit. Also it manages the IP adresses via DHCP enabled.
    The Windows PC, iMac and MX895 are directly connected to the remaining 3 network ports of the Time Capsule. The Time Capsule is a 2ng gen one equipped with a Samsung 2TB drive. WiFi on the Time Capsule is disabled. Firmware is 7.6.3
    And here is the problem description:
    After adding the Time Capsule to the network, there was no problem configuring it as a switch with Time Machine sharing available to the 3 Macs. Everything worked as expected... until...
    ...the Time Capsule does not respond any more. In more detail:
    The LED of the capsule is still green, not blinking or amber!
    I can access the capsule with Airport Utility but as soon as I try to do a remote restart, the Time Capsule is not responding any more.
    First I thought: "Okay, probably there has happened something" but I didn't care much about it and did a restart by pulling the power cord out and plug it back in after some seconds. Then it seems to work again... for some hours/days...
    ...then it happened again:
    My MacBook's Time Machine tells me that "the network drive does not respond", "...does not exist" or "...identity has changed". It seems to happen randomly, I don't have a clue what is causing this!
    What I have tried to fix this:
    Tried another Time Capsule (1st gen) with the same hard drive
    Tried this 1st gen with another Samsung 2TB HD
    Reset the 1st and 2nd gen TC and started with fresh backups
    Tried different TC settings, like transfering DHCP from the Fritz! to the TC, fixed IP
    Reset the complete Time Machine settings on all Macs and configured it again
    At the moment I'm trying, if a specific Mac in the network causes the issue by disabling the automatic Time Machine backups. I checked the TC log with the old Airport Utility - there is no error.
    I know, this is a bit strange and maybe I make some mistake, but I don't know what to do next. Maybe someone has an idea or can give me a hint what to try.
    Any help is very appreciated.
    Thanks
    Alex

    I don't see anything wrong in your setup.
    Unfortunately I think this is just network bug in mountain lion and the TC.. this is fairly common that the two will lose connection and a reboot will get things perked up again for times varying from a few hours to days or weeks.
    I don't have a bug killing solution either sorry to say.
    Let me recommend a few things.
    1. Do not use 7.6.3 firmware on those old TC.. go back to 7.5.2
    It has proven much more reliable. Do a factory reset after you flash back and redo the setup from scratch.
    2. Names on the TC for network sharing to be kept short, no spaces pure alphanumeric. Do not use apple type names with spaces and particularly the apostrophe.
    3. Whichever is running dhcp.. it should normally be the Fritz though, set dhcp lease to a very short time.. eg 30min. This will get the lease renewal faster and hopefully keep the ARP tables in the computers updated.
    4. But even though the TC is in bridge it should have a static IP address. That can help so you can link not just to the TC by name but also by IP address. The static IP is better handled by the Fritz though via fixed host type setting.. I am sure the fritz offers that.
    5. Just as a matter of interest why keep the link between the fritz and the TC to 100mbit.. both can do gigabit? It has nothing to do with the problem and there is nothing in the current setup that needs more than 100mbit link unless you are getting super speed on the 5ghz from the fritz. 
    Your post and picture of network are excellent.. helps when you are so clear.

  • Do 20 times varying

    hi all,
    can anyone plz tell me the use of Varying? tell me with example. actually i m using statement like below but i m getting only 0 values.--
    DATA: BEGIN OF WAGETYPES,
          LGA LIKE P0008-LGA01,
          BET LIKE P0008-BET01,
      END OF WAGETYPES.
    DO 20 TIMES VARYING WAGETYPES
                  FROM P0008-LGA01
                  NEXT P0008-LGA02.
        IF WAGETYPES-LGA IS INITIAL.
          EXIT.
        endif.
    DO 15 TIMES VARYING WAGETYPES
                  FROM P0589-LGA01
                  NEXT P0589-LGA02.
        IF WAGETYPES-LGA IS INITIAL.
          EXIT.
        endif.
    problem is that i m not getting any value in output only showing 0 value. can anyone please solve this issue?
    regards Nitin.

    Hi Saurabh,
      Check this sample code
    REPORT z_sdn.
    PARAMETERS:
      p_pernr TYPE pa0000-pernr,
      p_dat TYPE t548t-datar.
    DATA:
      BEGIN OF fs_pa0000,
        pernr TYPE pa0000-pernr,
      END OF fs_pa0000,
      w_dtype TYPE pa0041-dar01,
      w_dat TYPE pa0041-dat01.
    DATA: fs_548 TYPE t548t.
    DATA: t_548 LIKE
          TABLE OF
                fs_548.
    DATA:
      t_pa0000 LIKE
         TABLE OF
               fs_pa0000.
    DATA:
      fs_p41 TYPE p0041.
    DATA:
      t_p41 TYPE
      TABLE OF
            p0041.
    START-OF-SELECTION.
      PERFORM get_pernr.
      PERFORM get_data.
      PERFORM disp_data.
    *&      Form  get_pernr
    *       text
    *  -->  p1        text
    *  <--  p2        text
    FORM get_pernr .
      SELECT pernr
        FROM pa0000
        INTO TABLE t_pa0000
       WHERE pernr EQ p_pernr
         AND begda LT sy-datum
         AND endda GT sy-datum.
    ENDFORM.                    " get_pernr
    *&      Form  get_data
    *       text
    *  -->  p1        text
    *  <--  p2        text
    FORM get_data .
      LOOP AT t_pa0000 INTO fs_pa0000.
        CALL FUNCTION 'HR_READ_INFOTYPE'
          EXPORTING
            pernr                 = fs_pa0000-pernr
            infty                 = '0041'
          TABLES
            infty_tab             = t_p41
         EXCEPTIONS
           infty_not_found       = 1
           OTHERS                = 2
        IF sy-subrc <> 0.
          MESSAGE ID sy-msgid TYPE sy-msgty NUMBER sy-msgno
                   WITH sy-msgv1 sy-msgv2 sy-msgv3 sy-msgv4.
        ENDIF.
      ENDLOOP.
    ENDFORM.                    " get_data
    *&      Form  disp_data
    *       text
    *  -->  p1        text
    *  <--  p2        text
    FORM disp_data .
       READ TABLE t_p41 INTO fs_p41 INDEX 1.
       DO 12 TIMES VARYING w_dtype FROM fs_p41-dar01 NEXT fs_p41-dar02
          VARYING w_dat FROM fs_p41-dat01 NEXT fs_p41-dat02.
         IF p_dat EQ w_dtype.
           SELECT *
             FROM t548t
             INTO TABLE t_548
            WHERE datar = w_dtype
              AND sprsl = 'EN'.
           READ TABLE t_548 INTO fs_548 INDEX 1.
             WRITE: /2  'Personnel Number'(002),
                     15 'Begin Date'(003),
                     28 'End Date'(004),
                     40 'Date Type'(005),
                     53 'Date'(006),
                     65 'Date Text'(007).
             WRITE: / fs_p41-pernr UNDER text-002,
                      fs_p41-begda UNDER text-003,
                      fs_p41-endda UNDER text-004,
                      w_dtype      UNDER text-005,
                      w_dat        UNDER text-006,
                      fs_548-dtext UNDER text-007.
           EXIT.
         ENDIF.
       ENDDO.
    ENDFORM.                    " disp_data
    Regards
    Abhijeet

  • Issues with using SV Time-Varying Loudness.vi

    Hi,
      I am rather new to Labview and am having issues getting my Time-Varying Loudness calcuations to come out correctly. Attached is my current VI and a .csv file of a set of my data (calibrated in Pa. Sample rate = 50kHz for 5 seconds). When i run the VI it does not output what I would expect. Here are my questions:
    Time-Varying Loudness:
    1) What are there so many signals? There are hundreds of lines, but I only expected one.
    2) Why is my x-axis not a range of 1 to 24 like Barks should be?
    1/3 Octave Band Analsysis:
    1) Why does it look incorrect? Their shouldnt be a linear increase as a function of frequency...
    The data is of a part being squeezed and making a squeek. So it is a transient noise that happens around 2 seconds. Additionaly, how would I go about making a waterfall (Time(s),Frequency(Hz),Amplidtude(sones)) of this signal? Is there any easy way? or do I have to make all three signals and add them to make one plot?
    Thank you for your help! Let me know if you need more infromation,
    -Troy
    p.s. i included a picture of the results as well.
    Solved!
    Go to Solution.
    Attachments:
    TimeVaryingIssue.zip ‏668 KB

    Hi Troy,
    1) The SV Specific Loudness VI "chunks" data into 2 ms blocks, and then returns these as individual Specific Loudness vs. Sone plots.  The colored lines you are seeing on your graph are representative of the 2,500 2 ms time periods within your five-second acquisition.  Each of these plots contains 241 points, however they should occur in ten sample "steps", one for each sone.  The digital filter's buffer takes a bit to fill and kick in properly, however, so you may want to give your first few rows( 0-.02 seconds or so) a closer look before using them- you may see a number of unexpected zeroes around the lowest sones.
    2) Since you are using a chart, the x-axis will increment with every subsequent run (the previous data is retained.)  If you only want to display the most recent data, I would recommend switching to a graph, which can also be found in the graph controls palette.  Also, see above (#1) for why the x-axis is longer than 24 points.
    3) Remember that dB is a unitless measure, and can only be used in reference to another value. A typical reference for sound is 20 uPa, however you will likely need to equalize your input data and determine/set a dB reference.  You may want to take a look at SVL Scale voltage to EU.vi (EU stands for equalized units) and SVL Set dB reference.vi.  In your case, I believe the Octave plot is showing your dB relative to a default value of 1.  The values should be accurate with respect to one another, but you will need to provide a reference value to calibrate the scale.
    4) I think that this VI serves as a good example of how to go about creating a waterfall plot:
    Waterfall Display for Octave (DAQmx)
    http://zone.ni.com/devzone/cda/epd/p/id/5562
    You will need to break up your waveform into chunks, much like the specific loudness VI, but the basic concept is roughly the same (take waveform chunk, take octave measurement of chunk, append octave measurement output cluster to array of clusters, repeat for remainder of waveform, display)
    Phew!  That was quite a bit of information.  Let me know if that makes sense, and don't be intimidated by the detail and/or unfamiliar functions or methods  - you're definitely on the right track, or at the very least asking the right questions.
    Tom L.

  • Help, I am about to pull my hair out, can't get into a locked drive and Time Machine problem

    I've screwed everything up, I think.  I had Time Machine doing backups to an external 500Gig drive and somehow it got locked.  I went into Get Info to try and change the access but it won't allow me.  On top of this problem, my original drive died and I can't get into Time Machine to restore.  When I click "Enter Time Machine", nothing happens.  I created an eDisk and a startup disk to another external drive that I'm using now, but since everything that's been backed up is on the other drive that I can't access.  When I try accessing the drive it gives:  "The folder “G-DRIVE ” can’t be opened because you don’t have permission to see its contents."  I'm not knowledgeable enough to work from the command line, so if I need to do that to access the drive, please walk me though it.  As for the Time Machine problem, I have no idea how to recover anything since it won't even come up, it just sits there.  Outside of blowing my brains out, I don't know what to do.  Any help would be greatly appreciated as I can't afford to take it to Apple to let them try and fix it.

    Hello, not sure how this might affect a TM drive, or not, but...
    Here is what i needed to do for my drive "320GB HD", the last command is just for clean up
    Open Terminal and type these commands carefully with the spaces & change 320GB HD to the name of your drive.
    sudo chflags 0 "/volumes/320GB HD"
    sudo chown root "/volumes/320GB HD"
    sudo chmod 1775 "/volumes/320GB HD"
    sudo -k
    That said, these should be sufficient to do the job:
    sudo chflags 0 "/Volumes/320GB HD"
    sudo chmod a+rx "/Volumes/320GB HD"

  • Time out problem in BPS

    BPS friends,
    We have a planning function to copy Versions based with some filters. The copy function takes 5 hours and times out after that. The function is reaching max buffer size as recommended by SAP so we cant increase the buffer size anymore.
    We are on BW-BPS 3.5.
    How can I solve this time out problem? Please respond to me.

    Hi Pat,
    How many record did you copy ??
    Could you restrict the copy in not 1 package ??
    Package per package ...
    I suggest you ..
    e.g. you have restriction by a 0CALMONTH / something ..
    Then,
    You can copy e.g. for January to March, then March to August, etc.
    You can automate it by planning sequence.
    Hopefully it can help you a lot.
    Regards,
    Niel.
    thanks for the points you choose to assign.

  • When I tap the mail icon on my iPhone 4s, the menu of email servers pops up.  I already have a me acct that I check all the time, no problem.  So I choose iCloud, sign in and it tells me that I already have an acct-.so why can't I get to my emails then?

    When I tap the mail icon on my iPhone 4s, the menu of email servers pops up.  I already have a me acct that I check all the time, no problem.  So I choose iCloud, sign in and it tells me that I already have an acct….so why can't I get to my emails then?  I've turned the phone off and on twice....that has fixed it in the past but not this time....

    all fixed ha

  • I have the latest version of free Quicktime, Itunes  and unable to view video on my PC all i get is a pink screen the audio is OK i have uninstalled and installed several times same problem, i have a Iphone 4 and unable to view the content.

    i have the latest version of free Quicktime, Itunes  and unable to view video on my PC all i get is a pink screen the audio is OK i have uninstalled and installed several times same problem, i have a Iphone 4 and unable to view the content.

    Open your QuickTime control panel (either via the Control panels, or by going "Edit > Preferences > QuickTime Preferences" in the Quicktime Player). In the Advanced tab, uncheck Enable Direct3D video acceleration:
    ... and click OK. Quit and restart the QuickTime Player prior to checking to see if the settings change has had any effect.

  • Time offset problems with file i/o

    Hello everyone, I'm having a problem with the file i/o VI's. I require my application to save serial data at constant five minute intervals. The problem I'm currently seeing is that on each save to a file a time offset is being added which eventually becomes seconds, then minutes and so on. Since this application is meant to be run for a whole year this is a serious problem.
    Attached is the VI, an Arduino program simulating how the DAQ sends data and a file showing my time offset problem. 
    Any ideas/suggestions/fixes are appreciated.
    Thanks
    Jose Molina
    P.S.
    To run the VI upload the code to an Arduino, select it's serial port in the popup VI then click on Ok. The VI will wait for a time that is a modulo of 5 then create a folder structure inside the same location as the LLB. Inside this folder structure should be a file with the data which should be saved every five minutes if left at the default averaging time.
    Attachments:
    7-8-2012.txt ‏3 KB
    Daq_Simulator.zip ‏1 KB
    Weather_DAQ.zip ‏117 KB

    Sorry I forgot to mention that the averaging time is configurable in the pop up vi at the start. I tried 20 seconds because it's much faster for testing than 5 minutes. Timing is being done by a simple counter that increments each time data is received. So if I receive data the timer increments by 5 because data is sent every 5 seconds. Once the timer is equal to the averaging time the data is sent to the enqueue function and then the blocking dequeue function on the second loop sends the data to the file save vi which then saves the data to the file. 
    Attachments:
    counter.PNG ‏13 KB

  • Question on Time Variant

    Hello All
    How is the time variants gets the data, Do we need to LOAD data from Source system, like how we do for Master Data Load ?
    Thanks, looks silly questions, but good to understand ....
    BI

    Hi,
    In rsa1 of BW goto the source systems. Right click on your source system and select Transfer Global Settings. This will do your job. You need not to LOAD any data from Source system.
    Hope this Helps,
    Thanks,
    Amit

  • Time consuming problem in Self update rule

    Hi all:
         We have time consuming problem in self update rule.I have ODS ZOMS001,for this we created self update rule.In process chain we include this self update rule and during delta update,it takes 20 to 25 mins even if there is two records or 10000 records.In delta for this self update rule,it takes the whole records in ODS
        EX: If i have 10000 records during initialise and 10 records in Delta update...For the delta self update rule it takes 100010 records..But it only update delta records values.
    we have to reduce the total time consuming for this self update during delta..
    Waiting for your inputs.
    It would be helpful for your valuable reply.
    Rgds
    MSK

    I think retransporting is the only option available to you. You cannot modify anything in your production system.
    IF you have a chance to speak with basis people,ask them to open the system status to modifiable for few minutes.
    and make necessary changes in production and bring it back to normal (This is not a best practise in all situations).
    hope this helps.
    Praveen

  • Time varying velocity input for servo motor

    I 'm running a PXI-8145RT CPU with a 7344 motion controller.I want to load a time varying velocity profile for my servo motor.How can I do this? The "load velocity" tile does not have an input for such a profile,but only for a maximum velocity that will be reached after a certain time.

    Are you using the Motion Assistant or a programming language like LabVIEW? If you are using the motion assistant, you can do a contoured move with a Position-Velocity-Time Profile. I have never done this, but it sounds to be what you are looking for. This assumes that you have a controller that can do contoured moves.
    Hope that this helps,
    Bob
    Bob Young - Test Engineer - Lapsed Certified LabVIEW Developer
    DISTek Integration, Inc. - NI Alliance Member
    mailto:[email protected]

  • Import times vary-explain this to me please

    Why is it that when I’m importing a CD to iTunes (this is with either a new CD or an old CD) the import times vary so drastically?

    2. It displays the objects on the stage. (It displays them one by one in the order in which they
    were dragged to the stage from the Library when you designed the game in the FLA.)what does he mean by saying display them on the stage?? because i cant see them without addchild method and he said the swf file display them??!!!!!!!!
    are you using pure AS3 or are you using the design tool in CS4/5
    when using the design tool in CS4/5 you can have objects in the library and drag them to the stage. this will automatically at the objects to the stage without having to call addChild()
    if you are using pure AS3 you don't have access to this and you have to explicity add all you objects using addChild
    Here’s the issue: if the class’s constructor method includes a reference to the stage or an object that
    is on the stage that hasn’t yet been displayed, you’ll get an error message saying this: here i cant understand any single word!!
    Error #1009: Cannot access a property or method of a null object reference.
    you would only need to add a reference to the stage for non DisplayObjects (e.g. generally things that aren't sprites or MovieClips)
    All DisplayObjects have access to the stage via the stage property. The stage property for an object is always null until you call addChild, not when they are constructed as you mention.
    if you are trying to use the stageWidth and stageHeight property you shouldn't do this in the constructor of the object instead you would need to add an Event.ADDED_TO_STAGE listener and then do any configuration based ont he stage within this listener.
    hope that clears it up a little

  • Frequency analysis of time varying data

    I want to add a routine for frequency analysis of before and after strong impulse on a body.
    Some vibration sensors will be attached to the body.
    In this case, I was told I need to use a time-varying method like wavelet or any other to analysis instead of simple FFT.
    I installed wavelet package but I have no idea how to use it.
    (Wavelet method seems to be popular in reduction of noise.)
    Only what I want to know is the frequency elements in dynamics.
    Can you recommend any tools (functions) for my purpose?
    Are there some LabVIEW examples?
    I am using LV2009 and some extra toolkits (developer suites).
    labmaster.

    labmaster wrote:
    I want to ask some curious things.
    1. I have to analysis the spectrum of frequency in dynamic signal.
    In case of presenting dB, how to know the frequencies?
    2. In high sampling rate (1MHz), the low frequency element can't be analyzed. (too small window for 60Hz in my last example).
    If so, generally, do I have to down sampling to ~1kHz for the 1MHz in wavelet or short time FT?
    Take a look on how the Express VI you are using are made. The Express VI you are using is located here
    C:\Program files\National Instruments\LabVIEW 2010\vi.lib\addons\Time Frequency Analysis\_express\_TimeFrequencySpectrogramConfig.llb
    The VI you need to open is the configure.vi. Copy this VI to your user.lib folder before doing any work on it.
    To answer your first question. The dB setting will change the Y axis scaling, and not the X axis scaling. Which is the frequncy axis 
    The step between each frequncy bin will be( number of Frequency bins/(Fsample/2)). So using 1 MHz may reduce resolution. Perhaps 10 KHz will be bettter for you to use. 
    Besides which, my opinion is that Express VIs Carthage must be destroyed deleted
    (Sorry no Labview "brag list" so far)

  • I have windows xp. I downloaded quick time no problem still can't get itunes to install. Still get same message (a program for this install to complete could not be run).

    I have windows xp. I downloaded quick time no problem still can't get itunes to install. Still get same message (a program for this install to complete could not be run).

    Try the following user tip:
    "There is a problem with this Windows Installer package ..." error messages when installing iTunes for Windows

Maybe you are looking for

  • How to use recovery partition for installing OS

    hello,          i tried a lot to recover my os with lenove own button for system restore but it did't work and finaly i install OS XP Professional and manualy install all drivers. i must wanna say to lenove mangment that their this way is absolut mor

  • Does anyone know how I can edit a site created by another user on my imac?

    Hi, We are a family new to our imac. One of us created a site with iweb. Now I want to get to the site and edit it? I don't see the site when I start iweb...Can someone provide an answer and any recommendations on how to set up multiple sites so that

  • TO_DATE to insert in DB

    Hi everybody I need insert the date and time to Data Base with TO_DATE, but I don´t know if is functioning TO_DATE to insert the time or only the date. Can someone help me? Thanks. Paul.

  • Forcing a

    Scripting noob here in search of assistance... I have a script that passes the following command to force the removal of a particular package: echo "y" | pkgrm -s /var/sadm/pkg <pkg name> 2>&1 | tee -a $logfile However, this will only work on package

  • Use of configurator across organizations

    Hi, I have developed configurator some time back and we had just 2 organizations then (Say V1 and M1, V1 being master org and M1 being manufacturing org). Recently a new sales office has come up in Europe (E4 - Netherlands), which only procures the c