Do I configure spanning-tree port type ed trunk on LACP port-channels

Hello,
Can't seem to see a clear answer and wondering if something could offer some advice please?
We are using LACP aggregation across all our 10 gig attached servers and also trunking them.  We're running a VPC pair of 5596 Nexus.
For a standard trunk port I always add the spanning-tree port type edge trunk to the interface config.
However I think I should be adding this to the overiding port-channel config.  At present a colleague has configured the VPC below omitting the spanning-tree port type config.
interface port-channel100
  description a-server
  switchport mode trunk
  switchport trunk allowed vlan 100
  vpc 100
The port member configs are these which do contain the spanning tree port type:
interface Ethernet1/1
  description a-server(1)
  switchport mode trunk
  switchport trunk allowed vlan 100
  spanning-tree port type edge trunk
  channel-group 100 mode active
I always try to keep the overiding port channel config the same as its members and obviously for most config, you can't have disparate configs anyway.
However for the spanning tree config the NexOS allows you to have the members with spanning tree port types and not have to reflect that in the port-channel.
However I have this issue with STP:
Switch1# show spanning-tree interface po100
Vlan             Role Sts Cost      Prio.Nbr Type
VLAN0100         Desg BKN*200       128.4996 (vPC) Network P2p *BA_Inc
Is this due to the inconsistency with my port channel to member configs?
Any advice would be gratefully accepted.
Thanks!

Hi Paul, there are some parameters you can define on individual ports and there are some of them that will be inherited from the port-channel configuration no matter what has been configured under the infidividual ports. Spanning-tree configuration is one of the inherited ones. As soon as the port joins into a port-channel, it will start to use spanning-tree settings under the port-channel. When it leaves the channel, then it can continue to use the individual configuration.
There is a nice summary here under NX-OS Interface Conf Guide > Port-Channel Conf:
http://www.cisco.com/en/US/docs/switches/datacenter/sw/6_x/nx-os/interfaces/configuration/guide/if_portchannel.html#wp1798338
Evren

Similar Messages

  • Spanning-tree link-type shared

    Hi,
    i 've this problem.
    My PC must boot OS (windows) from network (Server sends Operating System by PC's mac-address)
    PC needs a ip-address within 5-10 seconds.
    I try it using hub and PC loads correctly OS and works properly.
    I try on my network (without hub) using Catalyst Switch in 2 ways:
    IOS and CatOS
    For the IOS i find this solution:
    i use the follows CLI:
    spanning-tree portfast
    spanning-tree link-type shared
    in this case i resolved my problem.
    FOR catOS , this command not work properly
    i use the follows CLI:
    set spantree portfast mod/port enable
    set spantree link-type mod/port shared
    After, if i see the configuration , i find the CLI
    "set spantree mst link-type mod/port shared"
    Can you help me?
    Thanks
    FCostalunga

    Configuring a ports STP link type to shared is sort of invalid if the port is also configured as an STP portfast port. 'Shared' effectively means this is a half-duplex connection to a hub that may also be connected to another switch (hence it can't be a point-to-point link). Normal STP operation should operate over 'shared' links and you won't get the rapid start a P2P link has.
    If the port is connected directly to a host then simply configuring the port as a portfast port will be enough (it will also make it a P2P link by default).
    HTH
    Andy

  • Blocked Stack Ports on 2960X-48FPD-L Stack (Unstable Switch Stack!) Spanning Tree?

    I am having an issue where 2 2960X-48FPD-L Switches in a redundant flexstack (stack port 1 SW1 to port  2 SW2 and port 2 SW1 to port 1 SW2) ring. 
    At first running the 15.0(2).EX5 (and earlier EX3, and EX4) version IOS yielded all the ports on the stack master switch refusing to run spanning tree and would only link in amber and not pass any traffic other than CDP information (the slave switch linked in fine). 
    I upgraded to 15.2(3)E and this solved the problem of the ports not linking in green and participating in spanning tree. 
    Now, however, about every week or two I lose connectivity to the switch stack and I was able to go to the switch stack locally and found that for some reason the switch stack is blocking and unblocking VLANs on StackPort1 frequently (see below).  When I was at the site, I sometimes had connectivity, sometimes not.  A stack hard reboot brought everything back up, but this is the second time this has occurred and I would expect the same problem in the next week or so. 
    Has anyone else run into these issues, and have you found a solution?
    I'm guessing that if I either get rid of the redundancy on the switch stack or stack using Ethernet cables between switches the problem will go away, but then what is the point of using stackable switches in a non redundant low speed stack.  It seems to me that Spanning tree thinks that I have a spanning tree loop going on with the stack ports which I didn't even think was possible.   
    What do you think?
    Jim
    _BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:02:59: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking StackPort1 on VLAN0307. Port consistency restored.
    Mar 11 09:03:16: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:03:27: %SPANTREE-2-BLOCK_PVID_PEER: Blocking StackPort1 on VLAN0307. Inconsistent peer vlan.
    Mar 11 09:03:42: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking StackPort1 on VLAN0307. Port consistency restored.
    Mar 11 09:03:46: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:03:47: %SPANTREE-2-BLOCK_PVID_PEER: Blocking StackPort1 on VLAN0307. Inconsistent peer vlan.
    Mar 11 09:04:12: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking StackPort1 on VLAN0307. Port consistency restored.
    Mar 11 09:04:22: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:04:56: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:05:13: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with inconsistent peer vlan id 207 on StackPort1 VLAN307.
    Mar 11 09:05:13: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking StackPort1 on VLAN0307. Inconsistent local vlan.
    Mar 11 09:05:30: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:06:00: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:06:04: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking StackPort1 on VLAN0307. Port consistency restored.
    Mar 11 09:06:32: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:07:02: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:07:03: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with inconsistent peer vlan id 207 on StackPort1 VLAN307.
    Mar 11 09:07:03: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking StackPort1 on VLAN0307. Inconsistent local vlan.
    Mar 11 09:07:34: %SPANTREE-2-RECV_BAD_TLV: Received SSTP BPDU with bad TLV on StackPort1 VLAN1.
    Mar 11 09:07:45: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking StackPort1 on VLAN0307. Port consistency restored.

    Jim,
    We have also the same problem with our 2960-X switches (access) connecting to a pair of 4500x (VSS) except our issue is with Portchannel with 2 physical links connecting the 2960xs to the 4500.
    If we disconnect one of the physical links from the portchannel everything works fine, but when we connect the same physical link back all users lose connectivity and the physical link starts flapping. Here are some of the messages we see in the logs when both physical links are in the portchannel:
    Mar 10 18:00:43 EST: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with inconsistent peer vlan id 1 on Port-channel5 VLAN90.
    Mar 10 18:00:43 EST: %SPANTREE-2-BLOCK_PVID_PEER: Blocking Port-channel5 on VLAN0001. Inconsistent peer vlan.
    Mar 10 18:00:43 EST: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking Port-channel5 on VLAN0090. Inconsistent local vlan.
    Mar 10 18:00:58 EST: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking Port-channel5 on VLAN0001. Port consistency restored.
    Mar 10 18:00:58 EST: %SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking Port-channel5 on VLAN0090. Port consistency restored.
    Mar 10 18:01:29 EST: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/1, changed state to down
    Mar 10 18:01:37 EST: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/1, changed state to up
    Mar 10 18:01:48 EST: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/1, changed state to down
    Mar 10 18:01:51 EST: %LINEPROTO-5-UPDOWN: Line protocol on Interface TenGigabitEthernet1/0/1, changed state to up
    We have upgraded to 15.0(2a).EX5 and still have the same issue.
    We have a ticket open with Cisco and have sent them all the logs and debugs and waiting to hear back from IOS developers.
    HTH

  • STP Port type Network in VPC

    Hi All,
    I have a topology like two vpc peer connected to down catalyst switch 3750 with VPC 51. My left switch is primary in VPC and other is secondary.
    if i enable spanning tree port type Network on VPC member ports and peer link. Then Secondary peer device start generating BPDU's and advertise its own bridge ID to Down host swich.
    Then Can you explain how down switch react to that because in this scenario down switch recieve two different Bridge ID's one from Primary and other from Secondary on same port channel which is logical one port.
    How it gonna handle this?
    I read regardless of the Spanning-tree root, VPC primay always generate BPDU and seconday device only rely that bpdu and never generate itself.
    what if somebody enable spanning tree port type Network towards down host switch on VPC member ports. Type network would generate BPDU's.

    Hie Bhanu,
    The STP is working as expected in your design. For a gig port port cost is 4. So for 1st 2950 cost to root is 8 thr 3550a. For 2nd 2950 cost to root is 12 thr 3550a and 16 thr 3550b so first one in preferred and later one is blocked. But for 3rd 2950 cost to root is 16 thr 3550a but thr 3550 b it is 12. Hence 3rd 2950 forwards traffic thr 3550b-6513b-6513a. This operation seems to be ok unless you have some specific requirements to change.
    Changing port channel cost is not a good idea. both the 6500s are using this channel for communication between them. If you block this link, the 6500s will have to communicate thr all the access switches which is not a good design.

  • ESW 500 Spanning Tree Protocol

    Hi:
    I have designed my network as Follows:
    Cisco Catalyst 3750G Stack as the Core Switches
    Cisco ESW 500 Switches as the Edge switches
    I am trying to configure Spanning tree on my network with The Core Switches as the root. But i am having a problem with that.
    I set the Catalyst 3750 as the root Bridge for all Vlans. But i am having a hard time to configure that on the ESW 500 Switches, as there is no place to configure Per VLAN spanning tree.
    Once I configure trunk Ports between the Core and the Edges. The Edge Switches don't consider the the Catalyst 3750G as the root, although it is configured with 0 Periority.
    Can you please help me with that?

    Hi Mohamed,
    Thank you for participating in the Small Business support community. My name is Nico Muselle from Cisco Sofia SBSC.
    The reason for this not to work is the following : The ESW switches do not support PVST(+) or PVRST like the 3750G does, on the other hand, they support STP, RSTP, and MSTP (MSTP is not supported on the 3750)
    So, keeping this in mind, it will not be possible to implement your STP per vlan. In this scenario however, where you set the 3750 as a root bridge for all VLANs, you could easily use RSTP, which is functional on both 3750 and ESW500 switches.
    Hope this helps.
    Best regards,
    Nico Muselle
    Sr. Network Engineer - CCNA

  • Core (4500x vss) with Access HP switch spanning tree

    Hello Friends,
    i need your support to guide me for this type of topology network in-order to avoid loops...
    like
    2  4500X series switch configure as a VSS working as core switch
    in access layer i have HP switches which are connected with 1G fiber uplinks to each other (cascaded) and back to these Core switch for Vlan forwarding.
    i need help to configure  spanning tree  for such topology and avoid loops.
    Topology is in attached..

    Hi,
    you mean to say, connect each HP switch back to core (VSS) with 2 uplinks and configure as a ether-channel?
    Yes, exactly.
    actually that is  not possible because the lack of fiber cable between the cabinets (core to access) are not much cores.
    How could it not be possible? According to your drawing in your current design ASW-HP1 and ASW-HP3 both connect to the core VSS, core anyway. So it is just a matter of connecting ASW-HP2 to the core.
    Of course you want 2 uplinks from each HP.
    HTH

  • Can I disable spanning-tree in a vpc domain ?

    i have two N7718s in a vpc domain and each have a vpc connection to  300+ TORs(non cisco switch).
    each 7718 have 300+ trunk port and a trunk port carring 80 vlans . so the logical port number is 300*80 = 24000
    the problem is n7k r-pvst logical ports limit is 16000,it causes the vpc primary 7718 ping latancy time exceed 1000ms
    2 ways to solve this problem : use mst instead of rpvst or disable spanning-tree
    if i use mst , the logical ports limit is 90000, the problem will appear one day
    so i want to disable spanning-tree . 7718s' vpc link to TOR use lacp ,it will prevent some  layer2 loops. can i do it?

    I have the same problem. :)

  • Spanning Tree on 2950 (High CPU)

    Just swapped out a 2924 with a 2950 (Copying config as closely as the 2950 would allow), and now icmp to Management IP is extremely latent (200m/sec+ from server connected directly to it)....icmp through the 2950 is unaffected.
    Spanning tree appears to be the culprit:
    36 12275368 3206214 3828 4.99% 4.07% 4.05% 0 Spanning Tree
    2950 connects to Cat4k on multiple ports (Both trunks/Non Trunks)
    spanning-tree mode is pvst on 2950.
    Hoping someone has come across this before :)
    Regards,
    MB

    Further investigation revealed that all the cat4k's vlans where in the 2950's dynamic table (show mac-address-table dynamic) - These vlans where definitely not supposed to be there, so I checked out the interconnecting ports(On Cat4k) to discover that about 5 had turned into trunk ports!(Does CatOS automagically enable trunking on ports in certain circumstances?)
    Systematically disabling trunking on these ports stopped all the cat4k's vlans being advertised to the 2950, and also reduced the cpu of spanning tree:
    36 15213172 3875075 3925 1.14% 1.37% 1.61% 0 Spanning Tree
    icmp had now also dramatically reduced.
    Regards,
    MB

  • Spanning tree selection

    Can anyone please tell me how spanning tree decides where to block a certain port, and also how would I change this port so I can block the port on my choosen switch ?
    thanks
    Carlos

    Hi
    please find the below how it is
    http://www.cisco.com/en/US/partner/tech/tk389/tk621/technologies_configuration_example09186a008009467c.shtml
    if its useful just rate it

  • How to implement uplink redundancy and spanning tree in SFP-300 switches

    We have several Small Business 300 Series Managed Switches, the 10/100 ones with PoE, the first generation ones.
    We've been advised to implement uplink redundancy and spanning tree on these switches.
    I'm sure spanning tree is a checkbox somewhere in the web interface.
    How does one implement uplink redundancy besides interconnecting the switches plus turning on spanning tree (RSTP)??
    Thank you, Tom
    P.S. I also tried to file a service request but it does not work, I get: "Error 500: Request processing failed; nested exception is java.lang.NullPointerException"

    Hello Thomas,
    Thanks for using the Cisco Small Business eSupport Community. I've looked through the articles that are available in our Knowledge Base and found a few that I hope will be able to assist you in setting up spanning tree and link redundancy on your SFP300s:
    In regards to link redundancy, the following article on LAG can hopefully provide some guidance:
    Link Aggregate Group (LAG) Configuration on 200/300 Series Managed Switches
    And for your question on setting up STP, here are a few articles with additional information:
    Configure Spanning Tree Protocol (STP) Status and Global Settings on 200/300 Series Managed Switches
    Setup Spanning Tree Protocol (STP) on a Interface on the 300 Series Managed Switches
    I hope that this information helps! Please remember to mark your question as answered and rate if this solves your problem.
    Best,
    Gunner

  • Spanning-Tree Port Type Edge & Router

    I am wondering if a switch trunk port that is facing a router that is connected with subinterface can be classified as an edge port in the eyes of Spanning-Tree.
    Thanks.

    Ricardo
    You should configure the switchport as "spanning-tree portfast trunk"
    As Glen says that is assuming you are not connecting to a switch module on the router.
    Jon

  • Nexus spanning tree pseudo configuration

    Hi
    I am trying to understand the pseudo configuration commands in a Nexus hybrid topology.
    I have vlans a, b and c only in the vPC side of the topology.  I have peer switch configured and the same stp priority on both switches.
    In the standard Spaning-tree topology I have completely seperate vlans x, y and z.
    What should I be configuring in the pseudo config section ?  Do I define a pseudo root priority for all vlans a, b, c and x, y, z or just for the standard spanning tree vlans x, y and z.  I need to avoid and, even short, spanning tree outages if I take one Nexus out of service for a short time.
    My thinking is that if one Nexus is out of service the physical mac will be used and potentially reduce the root priority of the vPC vlans causing a TCN and STP recalculation in vlans a, b and c.  This can be avoided by configuring a pseudo root priority for all Vlans lower than the current spanning tree priority shared by the vPC peers.  Is this correct ?  However, since I have a shared priority of 8192 on current vPC vlans will configuring, for example, a pseudo root priority of 4096 on those vPC vlans won't this also cause the TCN and recalculation I am trying to avoid ?  Is the benefit of the pseudo root config only obtained if it is configured at the start when the vPC is formed and prior to the peer switch command being issued ?
    Thanks, Stuart.

    Hi Ajay,
    It is recommended that switch-to-switch links are configured with the spanning-tree port type normalcommand. The one exception is the vPC peer-link which is recommended to configure with the spanning-tree port type network command.
    Take a read of the Best Practices for Spanning Tree Protocol Interoperability from page 56 of the vPC Best Practice Design Guide for further information on this.
    Regards

  • Spanning tree root ports in back to back VPC

    Ok so I have a question about back to back VPC configuration.
    I have a back to back VPC from core to agg layer so that I have 2 logical switches in my path.
    However I am seeing an issue on the agg layer.  Traffic is traversing the VPC peerlink instead of being sent up to the core which is where the spanning-tree root is configured.
    Po1 is my uplink from the agg
    Po4 is my vpc peerlink on the Agg
    Po1              Root FWD 200       128.4096 (vPC) P2p
    Po2              Desg FWD 200       128.4097 (vPC) P2p
    Po4              Root FWD 330       128.4099 (vPC peer-link) Network P2p
    Eth2/6           Altn BLK 2000      128.262  P2p

    a little more info.
    Po1 is my uplink to the core
    Po4 is my agg vpc peer.
    I see 2 paths to root on one swith.  it is choosing Po4 (vpc peerlink) instead of Po1 (uplink to core)
    MST0000
      Spanning tree enabled protocol mstp
      Root ID    Priority    4096
                 Address     0023.04ee.be01
                 Cost        0
                 Port        4099 (port-channel4)
                 Hello Time  2  sec  Max Age 20 sec  Forward Delay 15 sec
      Bridge ID  Priority    8192   (priority 8192 sys-id-ext 0)
                 Address     547f.eea6.d2c1
                 Hello Time  2  sec  Max Age 20 sec  Forward Delay 15 sec
    Interface        Role Sts Cost      Prio.Nbr Type
    Po1              Root FWD 200       128.4096 (vPC) P2p
    Po2              Desg FWD 200       128.4097 (vPC) P2p
    Po4              Root FWD 330       128.4099 (vPC peer-link) Network P2p
    MST0000
      Spanning tree enabled protocol mstp
      Root ID    Priority    4096
                 Address     0023.04ee.be01
                 Cost        0
                 Port        4096 (port-channel1)
                 Hello Time  2  sec  Max Age 20 sec  Forward Delay 15 sec
      Bridge ID  Priority    8192   (priority 8192 sys-id-ext 0)
                 Address     547f.eea6.ce41
                 Hello Time  2  sec  Max Age 20 sec  Forward Delay 15 sec
    Interface        Role Sts Cost      Prio.Nbr Type
    Po1              Root FWD 200       128.4096 (vPC) P2p
    Po2              Desg FWD 200       128.4097 (vPC) P2p
    Po3              Desg FWD 200       128.4098 (vPC) P2p
    Po4              Desg FWD 330       128.4099 (vPC peer-link) Network P2p

  • 2960X 15.0(2)EX5 Stack Bug? Master Switch Ports link in Orange, no spanning Tree

    Is anyone aware of a bug in version 15.0(2)EX5 for 2960X Switches that would cause a switch in the master role to stop linking in new ports in green (and passing traffic).  I have 2 2960X-48FPD-L Switches in a stack and whichever switch I designate master will only link new connections in orange and not pass traffic.  All ports linked in show up/up and can be seen in a show cdp neighbor but won't pass any other traffic. 
    If I unplug the Stacking cables both switches become masters and ports linked in green on the previous member switch stay green, but after it switches to master any new connections plugged in only link in orange. 
    If I switch priorities and reboot the problem switches to the new master switch and the problem goes away on the member switch.
    Also, a switch in the master role does not show any spanning tree instances for ports in the orange link state. 
    Has anyone seen this issue and do you know of a solution? 
    Jim

    A quick update for those with this same problem.
    1.  15.2(3)E turned out to be very unstable causing my switch stack to randomly lockup/reboot one of the switches about once a week.
    2.  I downgraded back to 15.0(2)EX5 but found a workaround.  It turns out the switch stack with the 15.0 versions does not like the switchport voice vlan command on any of the interfaces on the master switch.  I simply removed the voice vlan configuration on the interfaces and all the switch ports linked in just fine.  I would prefer to run the phones on a voice vlan, but it still works without, just the PC's and phones are on the same vlan. 
    Jim

  • Spanning Tree Reconfiguration - If Root Port is down.

    Hello All,
    I have some doubt on STP reconfiguration if Root port is down ...Can any one help...?
    As per my understanding, if any port is down due to any reason, the corresponding bridge shall sends a TCN to the root bridge through the root port.
    Lets say if a root port is down on a bridge, and so, the topology has to be re-established. As the root port itself is down, how does the Bridge convey the TCN to the root bridge ?
    Thanks,
    RajaSekhar                  

    Hi Raja, if the root port is down, the TCN notification can't make it to the root bridge since the link is down. The affected device will rely on the last known good bpdu. When the affected device has it's designated port down, it will remove the alternate port from discard once it hits the max age table then progress through the listening, learning, forwarding, at this time the new tcn is sent through the spanning tree topology. Once the TCN reached the root bridge, the root bridge will send a configuration bpdu then the whole spanning tree topology will update.
    It can take up to 52 seconds to have the topology update in the entirety depending on spanning tree mode and size of topology.
    -Tom
    Please rate helpful posts

Maybe you are looking for

  • Split CLOB column to improve performance

    Hi All, We have a transactional table which has 3 columns and one among those is CLOB which holds XML data.Inserts are coming at 35K/hr to this table and data will be deleted as soon as job is completed. So anytime the total records in this table wil

  • Credit Card number disappears

    We have an odd situation for one of our customer The sales user1 enter the sales order and enter the credit card number under the customer Payment terms. When the user2 copies to an Invoice and drill down to the BP Payment terms the card number disap

  • Flex incompatibility issue with SDK 3.5.0.12683 and IE6

    Anyone have experience with issues for IE6 and Flex SDK 3.5.0.12683? As a secondary issue, does anyone know of a way to force a browser cache refresh? thanks Simon

  • Porting a Processing (32bit) library from Windows to Mac (64bit)

    Some months ago I developed a library in Windows for Processing (http://code.google.com/p/touchatag-processing/). It basically allows users to work with touchatag RFID readers and tags on the Processing environment. For the last couple of days I've b

  • RFC Communication - error CPIC return code 020, SAP return code 665

    Hello, I have created RFC destination for connecting SCM system from Solution Manager. Both the systems are Unicode. I am getting the following error -- ERROR                service '?' unknown LOCATION             SAP-Gateway on host gva4103 / sapgw