Error on PA infotypes

Hi,
    I got some errors while doing PA infotypes creation.please help me.
  Short text
    A table name, specified in an SQL command, is unknown.
What happened?
    Error in the ABAP Application Program
    The current ABAP program "SAPFP50P" had to be terminated because it has
    come across a statement that unfortunately cannot be executed.
What can you do?
    Note down which actions and inputs caused the error.
    To process the problem further, contact you SAP system
    administrator.
    Using Transaction ST22 for ABAP Dump Analysis, you can look
    at and manage termination messages, and you can also
    keep them for a long time.
Error analysis
    An exception occurred that is explained in detail below.
    The exception, which is assigned to class 'CX_SY_DYNAMIC_OSQL_SEMANTICS', was
     not caught in
    procedure "READ_DATABASE" "(FORM)", nor was it propagated by a RAISING clause.
    Since the caller of the procedure could not have anticipated that the
    exception would occur, the current program is terminated.
    The reason for the exception is:
    An invalid table name "PA9667" was specified in an Open SQL command:
    Due to one of the following reasons, the error occurs only at runtime:
    - the table name was specified dynamically, or
    - the SELECT clause, WHERE clause, GROUP-BY clause, HAVING clause, or
      ORDER-BY clause was specified dynamically.

Hi
Do the creation with the following steps correctly
Steps to create a HR Infotype:
1) Go to Transaction PM01.
2) Enter the custom Infotype number which you want to create (Should be a 4 digit number, start with 9).
3) Select the 'Employee Infotype' radio button.
4) Select the 'PS Structure Infotype'.
5) Click on Create... A separate table maintenance window appears...
6) Create a PS structure with all the fields you want on the Infotype
7) Save and Activate the PS structure
8) Go back to the initial screen of PM01.
9) Click on 'All' push button. It takes a few moments.
10) Click on 'Technical Characteristics'. Infotype list screen appears
11) Click on 'Change'(pencil) button
12) Select your Infotype and click on 'Detail' (magnifying glass) button
13) Give 'T591A' as subtype table
14) Give 'T591S' as subtype txt tab
15) Give your subtype field as subtype field
16) Save and come back to PM01 initial screen
17) Click on 'Infotype Characteristics' ... Infotype list screen appears
18) Click on 'Change' (pencil) button
19) Click on 'New Entries'
20) Enter your Infotype number and short text
21) Here we have to set different Infotype Characteristics as per the requirement. (Better open another session with some standard Infotype's infotype characteristics screen and use as the reference to fill yours)
22) Save your entries.
23) Now the Infotype is created and ready to use.
24) If you want to change the layout of the Infotype as per your requirement...
25) In the PM01 initial screen...Select 'Screen' radio button and give 2000 as the screen name, then click on edit.
26) In the next screen.. Select 'Layout Editor' and click 'Change'.
27) Screen default layout appears...here you can design/modify the screen..change the attributes of the fields..etc.
28) Save and activate. (Don't forget to 'Activate at every level)
Subtype Creation :
Transaction PM01 Goto Subtype Characteristics. Click on Append and then subtype. Enter the name and description of subtype on screen.
Then goto technical Characteristics and maintain the details of subtype there. I.e name of subtype i.e. component name defined in PSnnnn. Subtype table is T591A.
Subty.text tab is T591S and time const tab is T591A.
See:
http://help.sap.com/saphelp_46c/helpdata/en/4f/d5268a575e11d189270000e8322f96/content.htm
HR related site:
http://www.sapdevelopment.co.uk/hr/hrhome.htm
Enhancement of Infotype
Check the following
http://help.sap.com/printdocu/core/Print46c/en/data/pdf/PAXX/PYINT_INFOTYP.pdf
Infotype Enhancement overview screen
https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/60a7586d-edd9-2910-68a8-8204303835a1
Regards
Anji

Similar Messages

  • Error: insertion of infotype 1000 (return code 2)

    Hi All,
    We are trying to Update the Org Structure in ECC which is typically used for the MM Processes.
    When ever we are trying to update the BP or create a new BP for Few Specific Company Codes we are receiving the below error
    Error: insertion of infotype 1000 (return code 2).
    SImilary we also see this error as well
    Database update not possible, data record    01S 500304541001A0031
    Your inputs are highly valuable.
    Regards,
    Satya

    the problem you mentioned here is not the whole problem in my opinion, so let me take a few assumptions and you tell me if some/all of em are correct or alternately you put in more detail in your query.. ok?
    well here goes:
    1. you mentioned BP which is a business partner object but you did not talk about hcm at all so am assuming sap hr has not been implemented at all in your sap box... right/
    2. then the infotype 100 and insert error is the least of your worries if the above point is correct.
    3. then you also have some nominal positions in your sap box to support your logistics process...
    4. and then I am taking a wild guess here --> you are trying to have a relation between a position and bp objects directly ...
    well I may be totally off the rocker in the above but what you need to tell us  could be :
    1. explain the business process.
    2. then we talk about how you are doing the business process in sap (is hr implemented or not? if yes to what extent etc...) and dont limit this point to logistics,.. cover the whole gamut of how you are doing it in sap today and am sure it spans across hcm and logistics
    3. then, a bit more info on what you were trying to do in a step by step fashion,... and where exactly you are encountering the error,.. --> the reason am asking for this is --> in my expereince I have seen a lot of logistics guys who are gurus intheir areas of expertise but you talk sap hr they are like babies,.. and the vice versa is also true,.. so if you are not able to explain point 2 above in full this point will give the complete technical picture.
    provide the above and loads of folks here will be able to help you out.
    cheers

  • Error while creating infotype 1764

    Hi All,
    When i am trying to give special booking authorization for a student to a module in student file, i am getting an error msg " error while creating infotype 1764".   The same is working in EHP4 but not in EHP3.
    Pls give your valuable inputs to resolve the issue.
    Regards,
    Sravan

    Dear Sravan,
    Check whether module in question is included in appraisal or not. If not then maintain it.
    Hope it will solve your issue.
    Regards
    Vinod Kumar

  • Error while creating infotype message no. pg293

    Hi guys,
    I am creating a new infotype after creating the PS structure when i click on generate objects i get an error saying "An internal error has occurred" message no. PG293.
    kindly provide a solution.
    points will be rewarded.
    thanks

    INFOTYPE CREATION WILL BE TAKEN CARE OF THE ABAPER AS RAO SAID
    AS THE OUT PUT WILL HAVE TO SEEN IN ALL THE SERVERS THIS IS A LITTLE BIT TECHNICAL WORK
    Start transaction PM01, Create Infotype, by entering the transaction code.
    You access the Create Infotype screen:
    2. In the Infotype no. field, enter the four-digit number of the infotype you want to create.
    When you specify the infotype number, please remember to enter any leading zeros.
    3. Choose IT characteristics.
    This accesses the Display View “Infotypes”: Overview screen.
    4. Choose Table view   Display   Change.
    This accesses the Change View “Infotypes”: Overview screen.
    5. Create a new entry for your infotype.
    You can create new entries by
    – choosing Edit   New entries or
    – copying an infotype entry with similar characteristics.
    If you want to copy an existing entry, select the entry you want to copy and choose
    Edit   Copy as.
    6. Check the entries in the individual fields.
    Result: You have maintained the characteristics of your infotype.
    Please check the above config for maintaining your infotype in PA30 and also check your entries in T582A & S.
    Edited by: Sikindar on Mar 9, 2008 8:23 PM

  • Getting error while Updating Infotype 0377

    Hi All,
    I am using FM 'HR_ECM_INSERT_INFOTYPE' for updating data from an excel file in infotype 0377 but i am getting this error 'Entry   VSEL   does not exist in T5UBA (check entry)'. This is coming due to the foreign key validation on the fields BPLAN & LEVL1. So the records are not getting updated in the infotype. But when i am trying to create a record with same data manually through PA30 its getting created. Can you please tell me which FM is being used for infotype updation in PA30. If i use the same FM, may be my issue gets resolved.Thanks.
    Regards,
    Arpita.

    Please find the code below:
    CREATE OBJECT v_message_handler.
        CLEAR: v_is_ok.
        CALL FUNCTION 'HR_ECM_INITIALIZE_BUFFER'
          EXPORTING
            message_handler = v_message_handler.
        CALL FUNCTION 'HR_ECM_ENQUEUE_PERNR'
          EXPORTING
            pernr           = wa_p0377-pernr
            message_handler = v_message_handler
          IMPORTING
            is_ok           = v_is_ok.
        CLEAR v_error_mssg.
        IF v_is_ok IS INITIAL.
          PERFORM get_error_msg USING v_message_handler
                                      wa_p0377-pernr
                                CHANGING v_error_mssg.
          v_tot_err = v_tot_err + 1.
        ELSE.
    *      CALL FUNCTION 'HR_ECM_INSERT_INFOTYPE'
    *        EXPORTING
    *          pnnnn           = wa_p0377
    *          message_handler = v_message_handler
    *        IMPORTING
    *          is_ok           = v_is_ok.
    *      IF  v_is_ok IS INITIAL.
    *        PERFORM get_error_msg USING v_message_handler
    *                                    wa_p0377-pernr
    *                              CHANGING v_error_mssg.
    *        v_tot_err = v_tot_err + 1.
    *      ELSE.
    *        v_tot_suc = v_tot_suc + 1.
    *        CLEAR wa_error.
    *        wa_error-cnt = '1'.
    *        wa_error-pernr = wa_p0377-pernr.
    *        wa_error-desc = 'Data Successfully Uploaded'.
    *        APPEND wa_error TO i_error.
    *      ENDIF.
          CALL FUNCTION 'HR_INFOTYPE_OPERATION'
            EXPORTING
              infty            = '0377'
              number           = wa_p0377-pernr
    *         SUBTYPE          =
    *         OBJECTID         =
    *         LOCKINDICATOR    =
              validityend      = wa_p0377-endda
              validitybegin    = wa_p0377-begda
    *         RECORDNUMBER     =
              record           = wa_p0377
              operation        = 'INS'
    *         TCLAS            = 'A'
    *         DIALOG_MODE      = '0'
    *         NOCOMMIT         =
    *         VIEW_IDENTIFIER  =
    *         SECONDARY_RECORD =
            IMPORTING
              return           = v_return
              key              = wa_perdatakey
            EXCEPTIONS
              OTHERS           = 0.
          IF sy-subrc = 0.
            "Success
          ENDIF.
          IF v_error_mssg IS INITIAL.
            CALL FUNCTION 'HR_ECM_FLUSH_INFOTYPE'
              EXPORTING
                nocommit        = ' '
                message_handler = v_message_handler.
          ENDIF.
          CLEAR v_is_ok.
          CALL FUNCTION 'HR_ECM_DEQUEUE_PERNR'
            EXPORTING
              pernr           = wa_p0377-pernr
              message_handler = v_message_handler
            IMPORTING
              is_ok           = v_is_ok.
        ENDIF.
        CLEAR wa_p0377.
      ENDLOOP.
      FREE i_it0377.           "Clearing the internal table
    ENDFORM.                    " SELECT_UPLOAD_DATA
    Actually in this program i am fetching values from an excel file & updating them into IT0377.Yes the IT171 is maintained for those employees. CAn you please guide me as how to resolve this issue? If need more info, pls let me know.Thanks.

  • Error while updating Infotype P9002

    Dear Experts,
    I am trying to modify infotype P9002 using FM 'HR_INFOTYPE_OPERATION.....
    and I getting my dump error while uploading text format.
    some times I get message : No data stored for 9002 in the selected period.
    my requirement is: I need to modify amount fields in P9002 for some existing records in PA9002.
    My question is :
    1. how should be my ( notepad ) text format which is to be uploaded, should I include all the fields in P9002 in my notepad trext or just include all the fields in my internal table or only the fields which needs to be modified.
    2. If I modify infotype P9002 will the data gets modified in PA9002.
    Please advice
    Karthik

    hi,
        I read your error. You just use fm 'HR_MAINTAIN_MASTERDATA', for this we doesn't require to give the fm in bapi_emp_enqueue and bapi_emp_dequeue.
        You want to modify, so first of all you just get the begda and endda of that record, then pass these values in fm.
         For this you have to fill mandatory fields like pernr, and fields.nd
         You just have to pass table pprop. In this we have to fill infty, fieldname and fieldvalue for each and every field.
    thanks & regards,
         sekhar.

  • Error while updating infotype using HINUINFO_UPDATE

    Hi All,
    While executing the program 'HINUINFO_UPDATE'
    i am getting an error 'No object identification permitted for infotype 0582, subtype LTA'.
    After the approval for LTA claim is done in ESS i have executed the program 'HINUINFO_UPDATE' to update he infotypes 15 and 582. Infotype 15 is getting created but while creating the infotype 582 system gives the above error message.
    In the detailed error log system gives the following message.
    "You attempted to access a data record with the object identification 1. However, according to the Customizing settings, object identifications cannot be used for subtype LTA of infotype 0582".
    Helpful answers will be rewarded .

    Solved by SAP

  • Error in saving Infotype

    Dear Experts,
    while creating infotype in my name space it is not allowing me to save the structures(PS...,) which is automatically created by SAP.
    it is showing an error :
    Customer object TABL PS9250 cannot be assigned to
    package /ABC/ZTEST
    Regards,
    Anoop Chandran

    Ashu
    Please paste the error here then only we can give
    if possible write what you did what error you got
    I think you didn't create Data elements properly. Make sure you create Data element created actiated and activate strucre too.
    Then click on Generate or if it is 4.7 click on All button
    Best Regards

  • Error executing Custom Infotype..

    An Invalid table name PA9001 is mentioned in the open SQL Statement.
    Runtime Error:SAPSQL_INVALID_TABLENAME
    Exception:CX_SY_DYNAMIC_OSQL_SEMANTICS occoured in procedure READ_DATABASE but neither
    handled locally nor declared in the RAISING clause of its signature.
    Termination occoured in ABAP Program SAPFP50P- in "READ_DATABASE".
    The main Program was "MP900100".
    I did not do any modifications in the programming part.Even then I am getting the errors..

    I had faced these issues before while creation of custom infotype. But I found later that its the incorrect authorizations which is not allowing the system to create the structures.
    When you create an infotype, sap follows few steps to create various strcutures and table enties.
    But due to insufficient authorizations, many of them are skipped. e.g. A functional person does not have authorization to create tables/ structures through SE11. I think this is the reason why the table PA9xxx is not created in your case.
    Fix your authorizations, and recreate the custom infortype.
    Reward points if it helps.

  • Error when sending infotype 2 via ALE - start date

    Hi all,
    we are facing the following error when using the standard method for HR distribution: changes in infotype 2 cannot be processed in the receiving system; each change results in a 51 error in the iDoc, with message "PA0002 could not be updatedu201D (msg number 5-108).
    For some background: we're using message type HRMD_A06 and the standard configuration as described in the "ALE Quickstart" document. We've sent the full set of employee data via report RHALEINI, and use RBMDIDOC and change pointers to send changes on a daily basis. All infotypes are updated correctly except 2.
    From our tests, it seems that the problem is the following:
    - the initial send via RHALEINI created infotype 2 records with start date 01.01.1900. The sent iDocs had at the level E1P1TYP for infotype 2, start date 01.01.1800
    - the daily report RBMDIDOC is sending the infotype 2 records with their real start date (i.e. birthdate of the employee). Since this is later than 01.01.1900, the replacement of one infotype by another in the receiving system fails. By manually changing the start date of infotype 2 in the receiving system, the next update is successful --but we do not want to manually update all records in the receiving system.
    Has anyone else faced this or a similar issue with RHALEINI and infotype start dates?
    Thanks in advance,
    Mariana
    Edited by: Mariana Lasprilla on Feb 5, 2009 10:35 AM

    The mystery has been solved: customer system had a conversion rule for message type HRMD_A in order to send a fixed value of BEGDA for all infotype 2 records.
    ALE conversion rules are set via table TBD30.

  • Error for custom infotype in PPOME

    Hello Experts,
    I have created one custom OM infotype for object position.Now when i am trying to acccess that Infotype in PO13 it is working fine but when i am trying to acccess the custom infotype in PPOME it is giving a dump.
    EERROR:
    Error in the ABAP program "SAPLRHOMDETAIL_PP01" had to be terminated because it has come accross a statement which cannot be exceuted.
    An exception occurred.
    The exception, which is assigned to class 'CX_SY_ASSIGn_CAST_UNKNOWN_TYPE', was not caught in procedure "INIT_SUBSCREEN" "(FORM)" nor was it propagagted by raising clause exception.
    The reason for the exception is :
    The type "" dynamically specified with ASSIGN....CASTING TYPE is unknown.
    Please guide me where i am doing mistake.
    Thanks in advance.
    Shweta

    Hi Sudha,
    PM01 is the tcode.
    Similar questions were already answered in the following threads
    ABAP HR : Infotype Enhancement
    So please search and then post specific queries.
    rgds
    gayathri

  • Subtype ERROR in Custom infotype

    Hi,
    i have created a custome infotype.
    i have assigned a subtype for the same.
    but it is not working.
    when i press F4 in subtype field  error is displayed.
    ERROR MESSAGE is " infoytpe xxxx not supported".
    regards
    thiru

    I am also facing the same problem  .
    Can anybody tell how to remove this error.
    Thanx
    Prabhati

  • Error in custom infotype creation

    Hi
    I have created a custom infotype IT9100 .
    When I am seeing the screen layout in se51 information message
    Element PSPAR-ITTXT touches or overlaps other element
    ITTXT stores the infotype text
    Now when I am activating my screen its showing error
    Collision at target location.*
    Could you please let me know how to deal with such prob.
    P

    Hi,
    please check whether in the layout set may be those fields are overlaping.
    generally i didnt get those type of messages.

  • Error when create Infotype 0007-Planned Working Time of Personnel data

    Hi Experts,
    I'm creating Infotype 0007-Planned Working Time for Personnel data then having a error below.( I created Work schedule rule and Gennerated it).
    Feature structure cannot be recognized, please see documentation
    Message no. P0568
    Diagnosis
    Cause 1:
    The structure of the feature is not saved in the feature directory.
    Cause 2:
    The feature structure is not defined in the program that reads the feature.
    Cause 3:
    The feature that the program expects does not match the actual feature structure.
    Procedure
    Cause 1:
    Please advise your system administrator that all features must be regenerated. Please note that this generation must take place in client 000 first, and then in all other clients (report RPUMKF00 or the Generation function in the feature maintenance transaction (transaction PE03)).
    Cause 2:
    The feature structure must always be defined in the program reading the feature (see documentation for program RPUMKC00).
    Cause 3:
    Please contact your system administrator
    I did using T.Code PE03 in Client 000 but I don't know what is Features?
    Please tell me how solves it ?
    Thanks so much.
    Dungnv

    infotype 0007 reads two features
    SCHKZ  - Default value for Shift indicator
    TMSTA     DEFAULT VALUE FOR TIME MANAGEMENT STATUS
    Please have a look at both these features

  • Error when executing infotype in PA30

    Hi all,
    i have created an infotype. now when i am accesssing that infotype in PA30, it throws a run time exception (some people call it Dump). the error analysis in the dump is given as:
    An invalid table name "PA9804" was specified in an Open SQL command:
    Due to one of the following reasons, the error occurs only at runtime:
    - the table name was specified dynamically, or
    - the SELECT clause, WHERE clause, GROUP-BY clause, HAVING clause, or
      ORDER-BY clause was specified dynamically.
    when i check the infotype, there are no errors.can anyone tell me what the problem is?
    regards,
    Hamza

    Did you set up the settings for your infotype? If you did not, then you need to go to transaction PM01, enter your infotype, click on Technical Attributes, on the next screen scroll down all the way until you find your infotype, double click on it and enter the Database table name there.
    If this helps, don't forget to award points.

Maybe you are looking for

  • Hr_maintain_masterdata to create new emp, error='Pers num not yet assigned'

    Hi All, I'm going to need to use the fm hr_maintain_masterdata to create a new employee.  I've done up a test program just to get it working before i begin.  When i run the code below i keep getting the error 'Personnel number has not yet been assign

  • PDF form not working in Reader 7.0.5

    Hello! We had created PDF form with Adobe Designer to work with Acrobat Reader 7. It contains a submit button to send XML with results via e-mail. This form works fine with Reader 7.0.0., but not with version 7.0.5. - in the latter version the submit

  • CS4 crashes on launch as of today

    Friday I upgraded to 10.6.4 (after making a clone of my stable 10.6.3 system). Today I booted PS CS4 (11.0.2) for the first time and it crashed, with the attached (also sent to Adobe) crash report. I restored my 10.6.3 system with no change; then rei

  • Opening PDF Form in Body Page

    Hi, It will be really great if some one can answer two of my question. 1. Is it possible to open a deployed form into a subsection of our web browser where company logo, left navigation panel , right navigation panel remain on there postion and filla

  • Java 6 plug-in

    I have been updating Java 6 with update 1,2,3,5,7,11 and J2SE runtime environment 5.0 update 6,9,10. They are all listed in the add/remove program section of xp. Are they all being used when I use java or simply occupying space on the HD? Could I uni