Exit LabView, clean up code.

Hello!
I'm about to finish my LabView application. I have some problems left and I need help to solve them.
My porgram uses some C++ code (which I call from the "Call Library Function Node"). In LabView I've made a sequence where in the first frame all C++ init code is executed, the second frame is the main program and the last frame is the exit and clean up code. The clean up code must execute or there will be ports open, memory leaks, etc. My problem is that if you stop the program from the LabView menu stop button, the program terminates before the last frame is executed. I would like to either remove the LabView stop button or, connect the stop button to my exit code somehow.
Follow up question: If I make an .exe (which is pos
sible right?) are the stop start, stop, debug, etc -buttons still there? Or can you make a "real" application that don't use the LabView buttons to start, stop, etc?
Thanks in advance,
/Thomas

Hi,
I don't know how it is done in C++, but in asssembler, a (windows) dll has a
DllEntry Proc. C++ shoud not be too different.
If the dll is loaded, this proc is called, with reason= DLL_PROCESS_ATTACH.
If the dll is removed from memory, DLL_PROCESS_DETACH is the reason.
If the DllEntry proc is called with reason= DLL_PROCESS_DETACH (when the dll
is removed, e.g. when labview is closed, or all the dll references are
removed from memory), a proper cleanup can be made.
Of cource, this does require keeping track of all things to clean up (memory
created by the dll, etc.).
This is kinda fun, because you can make popups when a dll is loaded. The vi
does not even need to be started. Or you can make the popup appear when the
user is done with the dll, even if no vi is running.
Btw. In LV6, you can capture the 'close' event, and close everything
properly. You can choose to close the window, or to ignore the close.
Btw2. You can remove the menu (or just the exit), so the user is not able to
close LV.
Regards,
Wiebe.
"Tobe" wrote in message
news:[email protected]...
> Hello!
>
> I'm about to finish my LabView application. I have some problems left
> and I need help to solve them.
>
> My porgram uses some C++ code (which I call from the "Call Library
> Function Node"). In LabView I've made a sequence where in the first
> frame all C++ init code is executed, the second frame is the main
> program and the last frame is the exit and clean up code. The clean up
> code must execute or there will be ports open, memory leaks, etc. My
> problem is that if you stop the program from the LabView menu stop
> button, the program terminates before the last frame is executed. I
> would like to either remove the LabView stop button or, connect the
> stop button to my exit code somehow.
>
> Follow up question: If I make an .exe (which is possible right?) are
> the stop start, stop, debug, etc -buttons still there? Or can you make
> a "real" application that don't use the LabView buttons to start,
> stop, etc?
>
> Thanks in advance,
>
> /Thomas

Similar Messages

  • Why do I get "The exception Privileged instruction (0xc0000096) occured in the application" error message when exiting LabVIEW 6.1?

    I have created a vi that uses the LV-GPIB and database connectivity vis. The program runs fine and it ends execution by running the "Close Database Connection.vi".
    After closing out my front panel windows and exiting LabVIEW 6.1, I get an error dialog box that reads the message "The exception Privileged instruction (0xc0000096) occured in the application". What does this error mean and how do I resolve it?
    Thanks,
    Taf

    Hi Taf,
    Given the broad scope of your application, it may be best to try and isolate the problem down by taking out parts of your application and simplifying it down as much as possible until you can get a consistent version that throws this exception. I would first try to take out either the GPIB or database connectivity portions of the application to narrow down our problem. This error generally occurs when accessing DLLs and external applications, so I wouldn't be surprised if it's the GPIB or database. Let's try to see exactly which one it is and then we can dig deeper into that part of the code. Thanks for your cooperation!
    Jeremy L.
    National Instruments
    Jeremy L.
    National Instruments

  • VBAI 2011, possible to migrate directly to LabVIEW 8.6 code?

    Hi,
    Just wondering if VBAI 2011 can migrate inspections directly to LabVIEW 8.6 code.  I have installed on my computer:
    VBAI 2011
    LabVIEW 8.6
    LabVIEW 2010
    LabVIEW 2011
    NI Vision Development Module 2011
    I don't see the option for LabVIEW 8.6 on my menu.  Any suggestions?
    John Wu
    Riobotics Consulting
    Solved!
    Go to Solution.
    Attachments:
    problem.png ‏34 KB

    I encourage you to look at the Vision Builder AI LabVIEW API, which is supported in LabVIEW 8.6.
    This feature allow you to control Vision Builder AI from LabVIEW (open inspection, run once, get results etc.)
    Unless your application requires really tight hardware integration, with hardware that you can only do in LabVIEW code, the code you're going to write with the API will be much cleaner than working with the code generated, which is somehow complex.
    Look at the examples located here:
    C:\Program Files (x86)\National Instruments\Vision Builder AI 2011\API Examples\LabVIEW Examples
    Best regards,
    Christophe

  • How to find the user exit for the T-code 'RECN'

    Hi friends,
    I have a requirement as-
    In 'General Data with Fast Entry' tab of tcode 'RECN' there are 2 fields as contract conclusion date and contract end date.
    Now, the requirement is as if entered contract end date is less than contract conclusion date then we have to display a warning message as "contract end date cannot be less than contract conclusion date".
    So, how to find the right user exit to enter the code.
    Plz help me.I will surely reward points.
    Thanks,
    Rishi

    Hi Rishi,
    If User exits and BAdi's are not provided,  then  you will for Enhancement points.
    Procedure:
                     When you are in a particular transaction, Go to System--> status and you find the standard program of that particular screen. Go to SE38 and give that program name, display mode.
    After that you click on the spiral icon there onthe top. Then,
    You go to menu bar, Edit> Enhancement opitons> show implicit enhancement options.
    You will be shown the points where you need to write the code.
    For creating it you will go to Edit >  Enhancement opitons> Create.
    By this you will add some code in the standard programs.
    Reward points if it helps you.
    Cheers,
    Swamy Kunche

  • What can I do about "LabVIEW load error code 38: Failed to uncompress part of the VI."

    While attempting to load an executable LabVIEW application for LabVIEW 2009 SP1 on a Windows-XP machine when the following pop-up message occurs. "LabVIEW: Memory or data structure corrupt. An error occurs in loading VI 'NI_Gmath.lblib: Backward Bracket Search.VI'. LabVIEW load error code 38: Failed to uncompress part of the VI. The VI is most likely corrupt." What seems odd is that the same LabVIEW application loads fine when logged on as a privileged user account, but fails to load on a private user account.
    Attachments:
    2012-07-18 LabVIEW Load error code 38.jpg ‏1314 KB

    Here's a thought:
    So when something is decompressed, a temp folder is often used. 
    I have no idea why LabVIEW would be decompressing anything, but I suspect it is trying to put the decompressed file into a temp folder where the user does not have write permissions.
    In the .ini file for your executable, you can add a line that specified the location of the temp folder to use:
    tmpdir=C:\Temp
    On my Win7 machine, the location is:
    C:\Users\MyUserName\AppData\Local\Temp
    On WinXP, it is probably:
    C:\Documents And Settings\YourUserName\local settings\temp
     Try changing the tmpdir key in your ini file to something to C:\Temp and see if that helps.
    - john

  • User exit for rerapp t-code

    Hello,
    i m looking for user exit for rerapp t-code but i couldnt find anything about that from internet. it s about e coming invoice. the invoice is being committed from rerapp t-code; then the view is being matched with invoice and clicked documents button.  i m looking for a user exit when user click 'documents' button,
    Thanks a lot,
    Ayşegül

    Hi,
    Follow this steps, you will get the exact BADI.
    1.     Go to the TCode SE24 and enter CL_EXITHANDLER as object type.
    2.     In 'Display' mode, go to 'Methods' tab.
    3.     Double click the method 'Get Instance' to display it source code.
    4.     Set a breakpoint on 'CALL METHOD cl_exithandler => get_class_name_by_interface'.
    5.     Then run your transaction.
    6.     The screen will stop at this method.
    7.     Check the value of parameter 'EXIT_NAME'. It will show you the BADI for that transaction.
    Regards
    Chaitanya

  • User exit to substitute Tax code

    Hi  Guys,
    I want to know is there any user exit to substitute tax code in MM. we have substitution in FI which is fine but fails when doc. posted through MIRO, my MM consultant say as BSEG table is updated in FI simarly MSEG table is updated in MM, so if there is a substitution in FI to substitute the tax code similarly there should be an user exit or substituion to substitute tax code in MM.
    Any body can help locate user exit for tax code substitution in MM.
    Thanks,
    Shubham

    Hello Shubham,
    check this exit "EXIT_SAPMM06E_012". Reply if this serves your purpose.
    regards,
    Prashant Rathore.

  • Find active user exit for a transaction code

    Hi All,
    Please help to find the active user exit for a transaction code.
    for Ex. below is the list of user exits for package VA ( for creation of sales order and changing sales order). Let me know which user exit is active and which is not active.
      Exit name    Short text
      SDTRM001  Reschedule schedule lines without a new ATP check
      V45A0001  Determine alternative materials for product selection
      V45A0002  Predefine sold-to party in sales document
      V45A0003  Collector for customer function modulpool MV45A
      V45A0004  Copy packing proposal
      V45E0001  Update the purchase order from the sales order
      V45E0002  Data transfer in procurement elements (PRreq., assembly)
      V45L0001  SD component supplier processing (customer enhancements)
      V45P0001  SD customer function for cross-company code sales
      V45S0001  Update sales document from configuration
      V45S0003  MRP-relevance for incomplete configuration
      V45S0004  Effectivity type in sales order
      V45W0001  SD Service Management: Forward Contract Data to Item
      V46H0001  SD Customer functions for resource-related billing
      V60F0001  SD Billing plan (customer enhancement) diff. to billing plan
    Thanks & Regards,
    Sabu

    Goto TADIR table give program id as R3TR ,Objec type as CMOD and execute.
    You will get all active exits in system.
    Exits related to SD may be in ZSD package.

  • JDS: Panel will exit now. Error code is 3

    Good morning,
    first of all excuse my bad english. I have a very big
    problem with my Sun Blade 1000 with Solaris 10
    at home. I have a local 192.168.0.0/24 network with
    static configured ips on each host. The gateway
    (W2003K-Server) is configured to dial out to the
    internet via modem.
    The ips and hostname are well configured on the
    Sun Blade 1000 and on each other host. All values
    (ips, hostnames, hosts, ipnodes, nsswitch.conf,
    resolv.conf, defaultrouter) are correct configured and
    the local and global name resolution is fully functional.
    Now the problem:
    If Solaris is booted with the gateway up and running
    a user cannot login using JDS, giving the
    error "Panel will exit now. Error code is 3". If Solaris
    is booted when the gateway is down, anything is
    working perfect.
    There were no such problems using Solaris 9.
    I thought it was a name resolution problem. So i
    configured a local DNS-Server on the gateway and
    changed resolf.conf on the Blade, but that did not
    solve the problem.
    Does any one encounter similar problems. Does
    anyone know how to solve this problem?

    That's a licensing error. You can read through several possible solutions here. Also, you can download the Adobe Licensing Repair Tool, which is suggested in the first solution.

  • User Exits for a Trans code

    Can any one help me out about how to find out the user exixts available for a particular T-code?
    Kindly explain the step by step process.
    Thanks ,
    Priya

    Use below code. Enter Transaction code and the output will be list of all the user exits associated with it.
    *& Report  ZUSEREXIT                                                   *
    *& Finding the user-exits of a SAP transaction code                    *
    *& Enter the transaction code in which you are looking for the         *
    *& user-exit and it will list you the list of user-exits in the        *
    *& transaction code. Also a drill down is possible which will help you *
    *& to branch to SMOD.                                                  *
    REPORT zuserexit NO STANDARD PAGE HEADING.
    TABLES : tstc, tadir, modsapt, modact, trdir, tfdir, enlfdir.
    TABLES : tstct.
    DATA : jtab LIKE tadir OCCURS 0 WITH HEADER LINE.
    DATA : field1(30).
    DATA : v_devclass LIKE tadir-devclass.
    PARAMETERS : p_tcode LIKE tstc-tcode OBLIGATORY.
    SELECT SINGLE * FROM tstc WHERE tcode EQ p_tcode.
    IF sy-subrc EQ 0.
      SELECT SINGLE * FROM tadir WHERE pgmid = 'R3TR'
                       AND object = 'PROG'
                       AND obj_name = tstc-pgmna.
      MOVE : tadir-devclass TO v_devclass.
      IF sy-subrc NE 0.
        SELECT SINGLE * FROM trdir WHERE name = tstc-pgmna.
        IF trdir-subc EQ 'F'.
          SELECT SINGLE * FROM tfdir WHERE pname = tstc-pgmna.
          SELECT SINGLE * FROM enlfdir WHERE funcname = tfdir-funcname.
          SELECT SINGLE * FROM tadir WHERE pgmid = 'R3TR'
                                      AND object = 'FUGR'
                                    AND obj_name EQ enlfdir-area.
          MOVE : tadir-devclass TO v_devclass.
        ENDIF.
      ENDIF.
      SELECT * FROM tadir INTO TABLE jtab
                    WHERE pgmid = 'R3TR'
                     AND object = 'SMOD'
                   AND devclass = v_devclass.
      SELECT SINGLE * FROM tstct WHERE sprsl EQ sy-langu
                                  AND  tcode EQ p_tcode.
      FORMAT COLOR COL_POSITIVE INTENSIFIED OFF.
      WRITE:/(19) 'Transaction Code - ',
           20(20) p_tcode,
           45(50) tstct-ttext.
      SKIP.
      IF NOT jtab[] IS INITIAL.
        WRITE:/(95) sy-uline.
        FORMAT COLOR COL_HEADING INTENSIFIED ON.
        WRITE:/1 sy-vline,
               2 'Exit Name',
              21 sy-vline ,
              22 'Description',
              95 sy-vline.
        WRITE:/(95) sy-uline.
        LOOP AT jtab.
          SELECT SINGLE * FROM modsapt
                 WHERE sprsl = sy-langu AND
                        name = jtab-obj_name.
          FORMAT COLOR COL_NORMAL INTENSIFIED OFF.
          WRITE:/1 sy-vline,
                 2 jtab-obj_name HOTSPOT ON,
                21 sy-vline ,
                22 modsapt-modtext,
                95 sy-vline.
        ENDLOOP.
        WRITE:/(95) sy-uline.
        DESCRIBE TABLE jtab.
        SKIP.
        FORMAT COLOR COL_TOTAL INTENSIFIED ON.
        WRITE:/ 'No of Exits:' , sy-tfill.
      ELSE.
        FORMAT COLOR COL_NEGATIVE INTENSIFIED ON.
        WRITE:/(95) 'No User Exit exists'.
      ENDIF.
    ELSE.
      FORMAT COLOR COL_NEGATIVE INTENSIFIED ON.
      WRITE:/(95) 'Transaction Code Does Not Exist'.
    ENDIF.
    AT LINE-SELECTION.
      GET CURSOR FIELD field1.
      CHECK field1(4) EQ 'JTAB'.
      SET PARAMETER ID 'MON' FIELD sy-lisel+1(10).
      CALL TRANSACTION 'SMOD' AND SKIP FIRST   SCREEN.
    *---End of Program.
    Best Regards,
    Vibha
    *Please mark all the helpful answers

  • Labview load error code 10:VI version (8.2b23) is too old to convert to the current

    trabajo en la version de LabVIEW 8.2, 20th aniversary edition, Professional y cuando intentaba abrir la parte de examples en la primera ventana me aparecia el siguiente error:
    LABVIEW:VI version is too early to convert to the current labview version.
    An error occurred loading VI "find examples.vi".
    Labview load error code 10:VI version (8.2b23) is too old to convert to the current
    labview version (8.2.1f4)
    luego de la primera intaslacion de la version 8.2b23 tambien me salia el mismo error, desintale y reinstale pero igual, asi que probe instalar un parche que actuliza a la version 8.2.1f4, pero como ven sigo con el mismo problema ademas de intentar mass compile pero no me funcina al parecer son muchos VIs que hay que compilar... tambien busque el LabVIEW conversion kit, pero son para versiones demasiado anteriores agradeceria me ayudaran a solucionar este problema.
    MUCHAS GRACIAS
    ATT: Carlos Andres Rosero, Colombia

    According to this, 8.2b23 is an illegal, bootlegged copy of LabVIEW.

  • LabVIEW load error code 10?

    Hello..
    I have received an .llb file from support at Anritsu, for a Wiltron 56100a Scalar network analyzer. It contains numerous priceless VI's. Unfortunately, when I try to open it, I get an error..
    "An error occurred loading VI ''. LabView load error code 10: VI version (3.1) is too old to convert to the current LabView version (6.1)"
    Is there any way I can convert this code at all? It would be most valuable! Would it be possible to get ahold of an older labview version, perhaps 4 or 5, convert to that version, then convert to 6.1? We really need these drivers..
    Thanks for any suggestions!

    Go here
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=0
    Click on "become an Enthusiats".
    Write a short bio,
    Indicate what catagory,
    Submit!
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • An error occurred loading VI. LabView load error code 1: LabView load error code %ld: %p"

    I have been developing a VI file that has
    been working fine, until now. I am using 8.6.
    Every time I attempt to open this file
    I keep getting:
    How do I fix the error code:
    Labview: Memory is
    full.
    An error occurred loading VI. LabView load error code 1:
    LabView load error code %ld: %p”
    On a separate dialog:
    “Not enough memory to complete this
    operation.”
    I ran VI analyzer which told that the
    VI:
    One or more errors occurred during
    analysis.
    Testing errors tab – Vi not loadable
    and my file name. At the bottom in the error description I got:
    “Error 74. Memory or data structure
    corrupt. <my file path> and <file name>.”
    Could not be opened.
    Is there anything I can do to recover
    the file?

    Hi kevin_khan,
    I went ahead and tried to open it and got the error attached.
    Peter T
    Applications Engineer
    National Instruments
    Attachments:
    test.png ‏14 KB

  • LabVIEW load error cod %ld: %p

    All of the sudden, when I tried to open a VI, I got an error message that said, "LabVIEW: Resource not found.  An error occured loading VI 'VI name.vi".  LabVIEW load error code 1: LabVIEW load error code %ld: %p".  I tried to revert that particular VI to the previous version through source control, but that didn't help.  Does anyone know what I need to do to fix this?  Thanks!
    Kudos and Accepted as Solution are welcome!

    It was fine, and now I can't open the VI.  It is possible that I forcefully closed the VI a few times with ctrl+alt+del.  The name.vi is the host vi for an fpga application.  It interacts with user, calls .NET DLL to communite with a DUT, pass data to/from FPGA, etc.
    I had already looked at the link that you posted.  Not sure does it apply to me.  
    Kudos and Accepted as Solution are welcome!

  • Why I get Labview load error code 16?

    "Labview load error code 16 preventing me from opening the VI"
    "I'm having some problems opening a particular VI. I get an error called: "Resource not found"; "Labview Load Error Code 16; Could not load data space link information." This VI cannot be opened, but I would like to somehow get into it (some important codes are in it). The Labview version is 7, the size of vi is about 1.08 Mb, and the system is on a Windows 98. Thanks in advance."

    Hello James,
    Thank you for contacting National Instruments.
    Try opening the VI with another version of LabVIEW. You can also try placing the VI as a subVI and then viewing its block diagram.
    You're also welcome to post your VI, and we can try to open it up here.
    I hope this helps!
    Matthew C
    Applications Engineer
    National Instruments

Maybe you are looking for

  • Acrobat 7.0 Pro on Vista freezes when PDF from Multiple

    I try to create a PDF from multiple files and Acrobat just sits there looking stupid. I've checked for updates - Fully updated. It's from my CS2 Premium Professional edition. I have it installed on a Dell e1705 with Vista Home. Dual Processor, but st

  • Can't set up Outlook email in the Mail app. All fine on my phone but not after Yosemite upgrade

    I've gone through every Microsoft screen saying how each account should be set up and nothing is working. I've managed to set up my business account which 1and1 Webmail without any issues at all. I have tried pretty much everything I have seen on her

  • PSE 8.0 Cannot See All Tools

    Good Day Eveyone: I cannot see all the tools that are listed in PSE Help for PSE 8.0.  For example Healing Tool - I only see the Spot Healing Tool on side of my screen.  I do not see both clone tools.  How do I get these other tools listed?  Thanks.

  • Open Directory Storing AD information

    I am looking for documentation that explains that Open Directory does NOT house Active Directory account information (passwords specifically). It is my understanding that when a server is set up as an Open Directory master, it only references Active

  • Cursor Disappearing Upon Waking

    Since upgrading to 10.4.7, I've had a frequent problem with the arrow cursor not appearing after waking my G5 from sleep; also the desktop will not respond to keyboard commands. After I shut down the machine (holding power button for 5 sec) and turn