Failover cluster validation errors

We are trying to set up a failover cluster file server between two domain controllers running Windows Server 2012 RC.
When we go through the Validate Configuration wizard, we receive the following errors messages against the Active Directory configuration (names have been changed).
"It could not be determined whether node computer1.example.com is a read only domain controller because of this error: The object does not exist."
and
"Node(s) computer1.example.com computer2.example.com cannot reach a writable domain controller. Please check connectivity of these nodes to the domain controllers."
Does anyone have any ideas why this might be happening? Replication and DNS appear to be working fine for all other services.

I did some tracking down of the problem, and it appears that it stems from the cluster not being able to retrieve the node names.  The function specifically is called GetFqdnNodeNamesFromCluster( ).
It can be seen if you run "Get-ClusterLog" while the cluster is in the process of being created.  This error seems to be the root of the cluster creation failure.  Here is a stacktrace:
PS C:\Users\gamroot> Get-ClusterLog -v
VERBOSE: Connecting to cluster on local computer TESTNODE1.
VERBOSE: at MS.Internal.ServerClusters.Cluster.GetNodes()
at Microsoft.FailoverClusters.PowerShell.FCCmdlet.GetFqdnNodeNamesFromCluster(Cluster cluster, Boolean onlineOnly)
at Microsoft.FailoverClusters.PowerShell.GetClusterLogCommand.WrappedProcessRecord()
at Microsoft.FailoverClusters.PowerShell.FCCmdlet.ProcessRecord()
VERBOSE: at MS.Internal.ServerClusters.Cluster.GetCoreClusterGroup()
at MS.Internal.ServerClusters.SafeFilteredEnumHandle..ctor(Cluster cluster, Boolean filterCoreGroups, Boolean
filterCoreResources)
at MS.Internal.ServerClusters.SafeClusterEnumHandle..ctor(Void* enumHandle, Cluster cluster, ClusterEnumType
enumType, SafeClusterEnumHandleOptions options, SafeClusEnumHandleType safeClusEnumHandleType)
at MS.Internal.ServerClusters.NativeMethods.ClusterOpenEnum(Cluster cluster, ClusterEnumType enumType,
SafeClusterEnumHandleOptions options)
at MS.Internal.ServerClusters.Cluster.GetNodes()
VERBOSE: at MS.Internal.ServerClusters.ClusterRegistryKey.GetValue(String name)
at MS.Internal.ServerClusters.Cluster.GetCoreClusterGroup()
VERBOSE:
Get-ClusterLog : Failed to retrieve the list of nodes for 'TESTCLUSTER1'.
Could not retrieve the core cluster group for the cluster 'TESTCLUSTER1'.
An error occurred while querying the value 'ClusterGroup'.
Element not found
At line:1 char:1
+ Get-ClusterLog -v
+ ~~~~~~~~~~~~~~~~~
+ CategoryInfo : ObjectNotFound: (:) [Get-ClusterLog], ClusterCmdletException
+ FullyQualifiedErrorId : NotFound,Microsoft.FailoverClusters.PowerShell.GetClusterLogCommand

Similar Messages

  • Failover Cluster Validation Report Error with IBM USB Remote NDIS Network device

    We are setting up Microsoft Windows Server 2008 R2 Failover Cluster on IBM X3850 X5 and get errors in the Failover cluster Validation Report due to the IBM USB Remote NDIS Network Device is using APIPA adresses and both servers are using same APIPA-adresse.
    How should I configure the Server and OS for the Failover cluster to be MS approved?
    IBM don't recommend that i disable the Network device, but it is a possible solution!?!

    What I did was use ipconfig /all to see the settings it is using and then when and set the ip setting on the NDIS driver to be that except I increment the last value by 1 for each node so that they do not have the same IP address.   I ran the
    cluster validation again and it came up clean and I have not experienced any issues yet.  It does give warnings about it being an Automatic Private IP Address and should not be used, which is ok because we are not going to use it anyways.
    Rich Baumet

  • Cluster Validation error.

    I have 2012 R2 Failover cluster with two nodes.
    When I try to add third node and run Validation test, I've got error in Validation Report:
    "Two disks have been found on node Hyperv01.local.com with duplicate disk signatures or disk GUIDs. The disks involved are physical disk 2 and physical disk 12. There may be a Multipath I/O (MPIO) problem such as the software is not installed or is not
    working properly. If MPIO is not involved, or MPIO has been verified as working, you must either mask one of these disks off at this node, or run validation and specify a disk list that includes only one of these disks, for example by using the Test-Cluster
    cmdlet in Windows PowerShell."
    But disk signature and disk GUIDs are different.
    All disks connected via ISCSI.
    Can anyone please help?
    Thank you.

    Hi oxyGEN_ua,
    Please confirm your storage compatible with server 2012r2 and your do not use the disk which marked as active and please confirm all your node have the same update and hotfix,
    please install the following update.
    Recommended hotfixes and updates for Windows Server 2012 R2-based failover clusters
    https://support.microsoft.com/kb/2920151/en-us?wa=wsignin1.0
    I’m glad to be of help to you!
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Failover Cluster Validation Report with warnings

    Hi,
    I have 2 Node cluster on windows 2008 R2.I have run cluster validation report and found following warnings pls suggest and guide me health of cluster and how to fix and remove these warnigns. thx.
    Validate All Drivers Signed
    Validate that tested servers contain only signed drivers.
    Validating that the servers contain only signed drivers...
    The node 'cluster1.domain.com'has unsigned drivers.
    Device Name  Device Class  Driver Version  Driver Date  Manufacturer  Inf Name  Driver Name  Device ID  Description  Status  Start Mode 
    Virtual CloneDrive  SCSIADAPTER  5.4.4.3  1/15/2011 12:00:00 AM  Elaborate Bytes AG  oem1.inf  Value Not Found  ROOT\SCSIADAPTER\0000  Virtual CloneDrive  Value Not Found  Unknown 
    Unsigned drivers were found on one or more of the servers.

    Hi,
    you need to run iso files at your cluster nodes often?
    Well i think you need to provide iso files to your VMs. This is possible without "Virtual CloneDrive"!
    I have seen many errors with this kind of software up to bluescreens.
    But ok if you really need this software just ignore the warning from cluster validation report.
    The cluster will work correctly if this are the only warnings from cluster validation report.
    Regards
    Sebastian

  • Failover cluster Validation

    Hi
    If i have production servers working on hyper v failover cluster and i want for some reason to run the validaion on the failover cluster
    what is the consideration before i ran the validation ?
    shall i shutdown all vms?
    Thanka
    MCP MCSA MCSE MCT MCTS CCNA

    Hi Yasser,
    Here are a few articles that might help. I've pointed out a few of the key comments here, and it appears that storage validation is the only category that will cause downtime. So if you want to validate storage, then yes, you'll need to shut them down.
    http://technet.microsoft.com/en-us/library/cc732035(WS.10).aspx (Server 2008/2008R2)
    "By default, the wizard warns you if storage tests have been selected but will not be run on storage that is online, that is, storage used by clustered services or applications. In this situation, you can run validation tests (including
    storage tests) by creating or choosing a new logical unit number (LUN) from the same shared storage device and presenting it to all nodes. By testing this LUN, you can avoid disruption to clustered services and applications already online within the cluster
    and still test the underlying storage subsystem."
    http://blogs.msdn.com/b/clustering/archive/2011/06/28/10180803.aspx (Server 2008R2)
    "Across these dozens of tests, only a few of them will impact running cluster workloads and these are all within the storage category, so skipping this entire category is an easy way to avoid disruptive tests."
    http://technet.microsoft.com/library/jj134244#BKMK_RUN_TESTS (Server 2012/2012R2)
    "If a clustered role is using a disk when you start the wizard, the wizard will prompt you about whether to take that clustered role offline for the purposes of testing. If you choose to take a clustered role offline, it will remain offline
    until the tests finish."
    Thanks,
    Jared

  • Failover cluster validation tool report

    I have two same model and config HP server form 2 nodes cluster, in Windows 2008R2 enterprise, when use failover cluster manager validate a configure, the result report said system configuration - software update level, some software updates missing on 1
    node:
    KB3029944, KB3023562, KB3021952, KB3013455, KB3004394, KB2980245, KB2926765, KB2913152, KB2862966, KB2847311 and KB2709981 (all version is correct for Windows 2008R2 64bit)
     I try manual download from Microsoft and standalone install, all security update get "The update is not applicable to your computer" .
    So how to install security update back the sever match 2 nodes software level ? 

    Both server is same day purchasing inside hardware and firmware is same, only deploy Windows days is not same, Windows update method via internet, if both server is same why after Windows update some
    software updates missing on 1 node ?
    Honestly the failover cluster manager validate report all pass except system
    configuration - software update level not pass, if
    I don't care missing updates form cluster any large critical will happen?  

  • Access is denied messages in Win2012 R2 Failover Cluster validation report and CSV entering a paused state

    Been having some issues with nodes basically dropping out of clusters config.
    Error showing was
    "Cluster Shared Volume 'Volume1' ('Data') has entered a paused state because of '(c000020c)'. All I/O will temporarily be queued until a path to the volume is reestablished."
    All nodes (Poweredge 420) connected a Dell MD3200 shared SAS storage.
    Nodes point to Virtual 2012 R2 DC's
    Upon running validation with just two nodes, get the same errors over and over again.
    Bemused!
    List Software Updates
    Description: List software updates that have been applied on each node.
    An error occurred while executing the test.
    An error occurred while getting information about the software updates installed on the nodes.
    One or more errors occurred.
    Creating an instance of the COM component with CLSID {4142DD5D-3472-4370-8641-DE7856431FB0} from the IClassFactory failed due to the following error: 80070005 Access is denied. (Exception from HRESULT: 0x80070005 (E_ACCESSDENIED)).
    and
    List Disks
    Description: List all disks visible to one or more nodes. If a subset of disks is specified for validation, list only disks in the subset.
    An error occurred while executing the test.
    Storage cannot be validated at this time. Node 'zhyperv2.KISLNET.LOCAL' could not be initialized for validation testing. Possible causes for this are that another validation test is being run from another management client, or a previous validation test was
    unexpectedly terminated. If a previous validation test was unexpectedly terminated, the best corrective action is to restart the node and try again.
    Access is denied
    The event viewer on one of the hosts shows
    Cluster node 'zhyperv2' lost communication with cluster node 'zhyperv1'.  Network communication was reestablished. This could be due to communication temporarily being blocked by a firewall or connection security policy update. If the problem persists
    and network communication are not reestablished, the cluster service on one or more nodes will stop.  If that happens, run the Validate a Configuration wizard to check your network configuration. Additionally, check for hardware or software errors related
    to the network adapters on this node, and check for failures in any other network components to which the node is connected such as hubs, switches, or bridges.
    The Cluster service is shutting down because quorum was lost. This could be due to the loss of network connectivity between some or all nodes in the cluster, or a failover of the witness disk.
    Run the Validate a Configuration wizard to check your network configuration. If the condition persists, check for hardware or software errors related to the network adapter. Also check for failures in any other network components to which the node is connected
    such as hubs, switches, or bridges.
    Only other warning is because the 4 nic ports in each node server are teamed on one ip address split over two switches - I am not concernd about this and could if required split then pairs, I think this is a red herring????

    Hi,
    Such events happen because of the following reason:
    1- Client for Microsoft Networks and File and Printer Sharing for Microsoft Networks not enabled on all network interfaces. Check this KB article: http://support.microsoft.com/kb/2008795
    . Please make sure these two protocols are enabled on all cluster networks
    2- Network connectivity issue can cause this event as well. Please make sure the network cabling/Cards/Switches are correctly configured and working as expected
    3- Connectivity issue with the storage can also cause this event. Please make sure all the nodes are connected to storage. Check HBA/Cabling connectivity to SAN. Make sure
    that the SAN drivers are up-to-date.
    4- Antivirus may interrupt network communication and cause this failure. Please exclude CSV volumes from being scanned by AV: http://social.technet.microsoft.com/wiki/contents/articles/953.microsoft-anti-virus-exclusion-list.aspx
    5- Disable TCP Chimney related settings on all cluster nodes. http://support.microsoft.com/kb/951037
    6- Please check the Network Binding Order (http://social.technet.microsoft.com/Forums/windowsserver/en-US/2535c73a-a347-4152-be7a-ea7b24159520/hyperv-r2-csv-cluster-recommended-binding-order?forum=windowsserver2008r2highavailability)
    7- Firewall Rules For All Inbound and Outbound For Cluster and Hyper-V for all the Profiles
    8- Update NIC Driver/Firmware.
    9- Check Compatibility of the NIC with Windows Server 2012R2
    10- Set-NetAdapterRss - Resources and Tools for IT Professionals | TechNet : http://technet.microsoft.com/en-us/library/jj130863.aspx
    11- Check the Following Article http://social.technet.microsoft.com/Forums/windowsserver/en-US/e06fede9-931c-4dee-8379-4fd985e20f0a/hypervvmswitch-eventid-106
    12- General Updates to be applied on the nodes :
    Windows RT 8.1, Windows 8.1, and Windows Server 2012 R2 update rollup: November 2013 : http://support.microsoft.com/kb/2887595
    Windows 8.1 and Windows Server 2012 R2 General Availability Update Rollup :
    http://support.microsoft.com/kb/2883200
    Hope this helps.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Cluster Validation Errors

    Scenario:
    Trying to do "cluster across box" with Server 2012 R2 and ESXi 5.5 using
    http://pubs.vmware.com/vsphere-55/topic/com.vmware.ICbase/PDF/vsphere-esxi-vcenter-server-55-setup-mscs.pdf and I am getting some disk errors in the validation logs. 
    "A failure occurred while attempting to arbitrate for Test Disk 1 on node <hostname>. 0x80070022"
    "Node <hostname> holds the SCSI PR on Test Disk 2 but has failed in its attempt to bring the disk online. The requested resource is in use."
    The storage is a virtualized SAN serving out iSCSI LUNs to the VMWare hosts.  These LUNs are then presented to the VM's as RDM.  Both VM’s can see the shared disks just fine and I can even create the cluster.  I have rebuilt the VM's I am
    trying to cluster, destroyed the disks and started over from scratch yet the errors come back.
    I am at a loss.  I will be opening up support requests with VMWare and DataCore to assist but we do not have a Premium subscription for Microsoft.  Any ideas?

    Hi BlitzSonik,
    “Node <hostname> holds the SCSI PR on Test Disk 2 but has failed in its attempt to bring the disk online. The requested resource is in use” This error is typically caused
    by the MSCS incompatible storage and from the document you presented I found the iSCSI support for latest edition of MSCS is Server 2012, please confirm your design is supported.
    The similar thread:
    WS2012R2 SCSI-3 Persistent Reservation requirements
    https://social.technet.microsoft.com/Forums/Windows/en-US/b78f0b84-4054-47c8-bd1c-878d02b464ae/ws2012r2-scsi3-persistent-reservation-requirements?forum=winserverClustering
    The related VMware KB:
    Microsoft Cluster Service (MSCS) support on ESXi/ESX (1004617)
    http://kb.vmware.com/selfservice/search.do?cmd=displayKC&docType=kc&docTypeID=DT_KB_1_1&externalId=1004617
    I’m glad to be of help to you!
    *** This response contains a reference to a third party World Wide Web site. Microsoft is providing this information as a convenience to you. Microsoft does not control these
    sites and has not tested any software or information found on these sites; therefore, Microsoft cannot make any representations regarding the quality, safety, or suitability of any software or information found there. There are inherent dangers in the use
    of any software found on the Internet, and Microsoft cautions you to make sure that you completely understand the risk before retrieving any software from the Internet. ***
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Windows Failover Cluster Manager Error

    I have a node that is not able join the Hyper-V cluster that it was previously running in the cluster without problems.
    The cluster service encountered an unexpected problem and will be shut down. The error code was '2'.
    C:\Windows\Cluster>clussvc.exe -s
    -----------------------------+ LOG BEGIN +-----------------------------
    [CS] Starting clussvc as a service
    [CS] cluster service logging level is 5
    [CS] Caught exception ERROR_FAILED_SERVICE_CONTROLLER_CONNECT(1063)' because of 'StartServiceCtrlDis
    patcher( ServiceTable )'
        000007fe:fda6aa7d( ERROR_MOD_NOT_FOUND(126) )
        00000000:0018f5d0( ERROR_MOD_NOT_FOUND(126) )
        00000000:0018fbb0( ERROR_MOD_NOT_FOUND(126) )
        00000000:ffd1a368( ERROR_MOD_NOT_FOUND(126) )
        00000000:0018f5a0( ERROR_MOD_NOT_FOUND(126) )
        00000001:e06d7363( ERROR_MOD_NOT_FOUND(126) )
    [CS] About to exit process...
    C:\Windows\Cluster>
    thank you for any guidance you may provide
    ron
    Ron Finnegan DHHS NIH NIMH LNT

    Hi Ron,
    Thank you for the reply.
    Have you installed this hotfix?
    http://support.microsoft.com/kb/975486
    Related information:
    http://blogs.technet.com/b/rspitz/archive/2010/08/26/the-cluster-service-service-terminated-with-service-specific-error-183-0xb7.aspx
    http://technet.microsoft.com/en-us/library/cc756369(WS.10).aspx
    Tim Quan
    TechNet Subscriber Support in forum
    If you have any feedback on our support, please contact [email protected]  
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer
    your question. This can be beneficial to other community members reading the thread. 

  • DAG Failover Cluster Service Errors

    Hi all,
    I have six Exchange 2013 SP1 mailbox servers installed on Server 2008 R2 configured in two seperate DAG's (3 and 3).
    I'm using a single NIC on all the servers for replication and server connectivity. 
    I pre-staged the DAG computer object in AD (and assigned permissions), and configured DNS entries for both (confirmed and resolvable). I also configured the DAG network subnet and DAG IP address via EAC. 
    At the moment I have active DB's on each server and then a passive copy on each other server, and all instances are healthy.
    However, when I look in the WFC on each server, there are a ton of errors in the cluster event logs. All of the nodes show up as green, along with the cluster network, but the cluster shows "The cluster network name is not online". 
    Cluster resource 'Cluster Name' in clustered service or application 'Cluster Group' failed.
    Cluster network name resource 'Cluster Name' cannot be brought online. The computer object associated with the resource could not be updated in domain 'contoso.com' for the following reason:
    Unable to obtain the Primary Cluster Name Identity token.
    The text for the associated error code is: An attempt has been made to operate on an impersonation token by a thread that is not currently impersonating a client.
    The cluster identity 'DAG$' may lack permissions required to update the object. Please work with your domain administrator to ensure that the cluster identity can update computer objects in the domain.
    I've removed and re-added DNS records, and double checked the permissions on the CNO object. What else can I do?

    Hi,
    Its not a good idea to add a static DNS-Record for the DAG - Remove it and on the member holding the PAM, run ipconfig /registerdns.
    Martina Miskovic
    It also turns out that the CNO objects were never re-enabled by Exchange during the DAG creation process. Once I followed your steps above, and manually enabled the object in AD, the DNS entries auto-populated and everything came online.
    Thanks for the help!

  • Microsoft update KB 3002657 and 2008 R2 failover cluster for virtualization

    After installing Microsoft update KB 3002657 on my Windows 2008 R2 failover cluster for virtualization, nodes in cluster lost connection to CSV and all my VM's were moved to node owning the volume.
    I lost whole day to solve that problem.
    But should i keep that update not installed on cluster nodes or anyone maybe has a solution for that ?

    Hi a3pl,
    Unfortunately, the available information is not enough to have a clear view of the occurred behavior from the cluster perspective. Please offer us
    more information such as the failover cluster validation error, the failover error event ID, with the current information it is difficult to presume which part may cause this issue, we strongly suggest you install the following update when you use failover
    cluster.
    Recommended hotfixes and updates for Windows Server 2008 R2-based server clusters
    http://support.microsoft.com/en-us/kb/980054
    I’m glad to be of help to you!
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Install Guide - SQL Server 2014, Failover Cluster, Windows 2012 R2 Server Core

    I am looking for anyone who has a guide with notes about an installation of a two node, multi subnet failover cluster for SQL Server 2014 on Server Core edition

    Hi KamarasJaranger,
    According to your description, you want configure a SQL Server 2014 Multi-Subnet failover Cluster on Windows Server 2012 R2. Below are the whole steps for the configuration. For the detailed steps about the configuration, please download
    and refer to the
    PDF file.
    1.Add Required Windows Features (.NET Framework 3.5 Features, Failover Clustering and Multipath I/O).
    2.Discover target portals.
    3.Connect targets and configuring Multipathing.
    4.Initialize and format the Disks.
    5.Verify the Storage Replication Process.
    6.Run the Failover Cluster Validation Wizard.
    7.Create the Windows Server 2012 R2 Multi-Subnet Cluster.
    8.Tune Cluster Heartbeat Settings.
    9.Install SQL Server 2014 on a Multi-Subnet Failover Cluster.
    10.Add a Node on a SQL Server 2014 Multi-Subnet Cluster.
    11.Tune the SQL Server 2014 Failover Clustered Instance DNS Settings.
    12.Test application connectivity.
    Regards,
    Michelle Li

  • Windows 2012 Server multinode failover cluster (6 nodes)

    Dear All,
    We are facing problem of Huge time takes for cluster validation test on IBM Blade Server with Storage. The details are given below. 
    Escalated with IBM OEM, confirmed that "there is no hardware issue with Server and storage, Please take support from OS (Microsoft) OEM as 2 node validation test is working fine".   
    Server : IBM BladeCenter S-HS23
    OS : Windows 2012 X64 Datacenter Edition
    MPIO.SYS Version: Default came from OS
    Note : Failover cluster validation test is successful on 2 nodes in 15 min with 5 shared volumes between 2 nodes and also between set of 2 on other 6 nodes.
    When we are running validation test on 6 nodes its taking 30 min in list and more than 45 min potential cluster disk.
    Thanks in adv for support from your end....
    T & R,
    Kamlesh
    kamlesh

    Hello,
    I'd ask in the
    High Availability (Clustering) subforum of the Windows Server forums.
    Karl
    When you see answers and helpful posts, please click Vote As Helpful, Propose As Answer, and/or Mark As Answer.
    My Blog:http://unlockpowershell.wordpress.com
    My Book:Windows PowerShell 2.0 Bible
    My E-mail: -join ('6F6C646B61726C40686F746D61696C2E636F6D'-split'(?<=\G.{2})'|%{if($_){[char][int]"0x$_"}})

  • Server 2008 Hyper-V Failover Cluster Error on Domain Controller Reboot

    I am pretty new to Hyper-V virtual but I have 2 Hyper-V Clusters, each with 2 Nodes and a SAN, 1 Physical Domain Controller for failover cluster management and 1 virtual domain controller as backup.  All is running well, no issues.  I installed
    windows updates on the physical DC and upon reboot, got an error 5120 on cluster 2 that says "Cluster Shared Volume 'Volume1' ('Cluster Disk 1') is no longer available on this node because of 'STATUS_CONNECTION_DISCONNECTED(c000020c)'.  All I/O will
    temporarily be queued until a path to the volume is reestablished.  It pointed to the 2nd node in that cluster as being the issue but when I look at it, it is online and all healthy so I don't understand why the error was triggered and if the DC would
    go down for a failure, would that node not be able to access the CSV permanently.
    Appreciate any help anyone can provide.

    Hi mtnbikediver,
    In theory, if you has the correct configuration of cluster the DC restart will not cause the CSV down, does your shared storage installed on your DC? Did you run
    the cluster validation before you install the cluster? We strongly recommend you run the cluster validation before you build the cluster, same time please install the recommend update of 2008 cluster first.
    Recommended hotfixes for Windows Server 2008-based server clusters
    http://support.microsoft.com/kb/957311
    I found a similar scenario issue the DC restart will effect the cluster network name resource offline, but it is for 2008R2.
    Cluster network name resource cannot be brought online when one of the domain controllers is partly down in Windows Server 2008 R2
    http://support2.microsoft.com/?id=2860142
    I’m glad to be of help to you!
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • MS- WIN SERVER 2008-R2 FAILOVER CLUSTER --ERROR 1127 ,1583

    DEARS ,
    I HAVE BEEN FACING PROBLEM FOR MY WINDOWS FAIL OVER CLUSTER SCENARIO.
    THE ERROR CODES ARE 1127 AND 1583 WHICH ARE STATING THAT
    All nodes IPv4 networks should be configured properly.
    Nodes which are using Automatic Private IP Address (APIPA) for adapter Cluster.will not be added to the Windows Failover Cluster. If the adapter is to be used by Windows Failover Cluster, the IPv4 properties of the adapter should be changed to allow assignment
    of a valid IP address that is not in the APIPA range.
    However , I have checked that all of my NIC adapters have valid Static IP addresses. Also , when one of the nodes is down ,it cannot look for another node.
    Please advise for the solution.

    Hi,
    Could you clarify your described “Nodes which are using Automatic Private IP Address (APIPA) for adapter Cluster.will not be added to the Windows Failover Cluster.” Did you
    found one of your cluster node “automatically” have the APIPA address? If so, it seems is the IP conflict issue.
    If it is not the IP address conflict issue, please try to disable your all the nodes firewall 
    or AV soft have the event 1583 typically cause by this function incorrect configured.
    More information:
    Event ID 1127 — Cluster Network Connectivity
    http://technet.microsoft.com/en-us/library/dd353958(v=ws.10).aspx
    Event ID 1583 — Network Connectivity and Configuration
    http://technet.microsoft.com/en-us/library/ee830320(v=ws.10).aspx
    Hope this helps.
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

Maybe you are looking for

  • How do I receive a serial number for lightroom 5

    I purchased a software CD from Amazon for Lightroom 5 upgrade and now I need a serial number so that it can be registered and operational.  The box shows these two numbers,  PN: 65215274  and also,  LTRM,5.0,MLP,UPG,UE001,DV. Neither of these numbers

  • How I Got iChat to Work

    I finally got my iChat to work after a lot of research, especially from reading this forum. I want to thank Ralph John (Great website), Tony defcom1 (netgear suggestions), and RJ in WI (for testing my iChat connection). I want to share with the reade

  • Using CAST function to convert to timestamp

    I have a select statement that runs via JDBC and is not using any index as timestamp is explicitly used. I would like to be able to convert to Date so the proper index can be used as this column is of Date datatype. I'm having "ORA-25137: Data value

  • Macbook pro running very slowly when the energy cable is unplugged?

    Hey Guys. My laptop has this exact same problem. I got it in March 2012, and it was working perfectly fine both on power and on the battery. I'm trying to apply this solution, but I'm stuck on step 3, because my Extensions folder is empty. There are

  • Print more than 255 columns ABAP List

    Dear gurus, We'd like to print this report S_ALR_87012357 on A4 paper. Thing is, the column is wider than 255 columns (342). I've made and use Z_65_342 format, but still when printing, it truncated, with same result as if i'm using x_65_255 format. I