FRM-92101 RUNTIME error - No HTTP headers received from runform

Oracle IAS 9.0.4 servers are configured to serve up webforms. The Server is configured to run only forms.Is it possible to run report files from this SERVER.
Iam getting FRM-92101 RUNTIME error - No HTTP headers received from runform.
Iam not able to run any reports.
Thanks
Himabala

Hello,
Q: Is it possible to run reports from Oracle IAS 9.0.4 server that is not running the reports server locally ?.
A: Yes
For the error FRM-92101 when using RUN_REPORT_OBJECT, check that the CLASSPATH contains the necessary jar files rwrun.jar and zrclient.jar .
Regards

Similar Messages

  • Frm-92101 happens when I open a form from another form and close it.

    Frm-92101 happens when I open a form from another form, check something, show a message to the user and exit the form to the previous form.
    Forms version: 10.1.2.0.2. Java: 1.6.0_23. Browser: IE6
    When I put before the "EXIT_FORM" two messages, everything is fine and the second form is closed and I repeat to the first form just as I wanted.
    In forms 9.0 it didn't happen.
    Does it have a connection with the fact I use JRE instead of JInitiator?
    Thank you.

    >
    There are numerous causes of the FRM-92101 error. I recommend you start your investigation by tracing your Forms session so you can see what your form is doing when the error occurs. Check out My Oracle Support document How to Use Forms Trace with Forms [ID 209372.1] for information on how to enable the trace. Also, take a look at My Oracle Support document Known Causes of FRM-92101 Error In Forms [ID 604633.1].
    Hope this helps,
    Craig
    >
    I have just found that there is a "Synchronize" command in one of the main attached libraries, and when I comment that command the application works well. But I don't want to comment it because it's a great library and I assume it has a part in the system.
    I have discovered that in the new Forms' help, the fact that the System.Current_Item mustn't be null so the command "Synchronize" will work, is mentioned. In the old Forms' help, that fact is not mentioned.
    So I tried to put it inside a condition that checks if the current item is not null, but the compiler doesn't recognize the "current_item". I don't know why. Because it's a library? So how can I check this? I can sent it as a parameter, but I don't want. Do you know something about it? Thank you.

  • Fieldpoint write.vi error - 33816 (Unexpected character received from Optomux response)

    Hi, I have been running a program for a few months now and yesterday I got an error at the fieldpoint write.vi error - 33816 (Unexpected character received from Optomux response). The program will run fine for approx. 5 minutes and then the error occurs, if I click continue the program will run fine again for another 5-10 minutes before occuring again. The field point module that is being affected is a digital output which is controlling a relay connected to a heating element. When the error occurs it freezes the program and if the relay happens to be on it can cause a potentially dangerous over temperature event. Luckily I happened to be in the room when it first occured but the program is supposed to rund 24-7. I tried taking off automatic error handling but that caused the program to run incorrectly.
    What is causing this error ?? Why did it just materialize ? How can prevent it from happening again ?
    Any insight would be greatly appreciated !

    beaster wrote:
    Hi, I have been running a program for a few months now and yesterday I got an error at the fieldpoint write.vi error - 33816 (Unexpected character received from Optomux response). The program will run fine for approx. 5 minutes and then the error occurs, if I click continue the program will run fine again for another 5-10 minutes before occuring again. The field point module that is being affected is a digital output which is controlling a relay connected to a heating element. When the error occurs it freezes the program and if the relay happens to be on it can cause a potentially dangerous over temperature event. Luckily I happened to be in the room when it first occured but the program is supposed to rund 24-7. I tried taking off automatic error handling but that caused the program to run incorrectly.
    What is causing this error ?? Why did it just materialize ? How can prevent it from happening again ?
    Any insight would be greatly appreciated !
    I believe Optomux was used for the serial connection scheme (please correct me if I'm wrong) so we are looking for something that could corruprt the serial comm.
    Quick Test:
    Try disconnecting the relay and run the program without the heater and external circuitry to rule out glitches etc.
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Frm-92101 getting error when running form using webutil

    hi
    I get an error FRM-92101:There was a failure in the Forms Server during startup. This could happen due to invalid configuration. Please look into the web-server log file for details
    i am using form version
    Forms [32 Bit] Version 10.1.2.0.2 (Production)
    problem is some time form runs and some time dont any solution or possibility???

    check this for configuration of webutil
    http://baigsorcl.blogspot.com/search/label/WebUtil
    Baig
    [My Oracle Blog|http://baigsorcl.blogspot.com/]

  • I receive a Runtime Error when trying to go from Organizer to Editor. It reads:  Microsoft Visual C   Runtime Error....Runtime Error....Program c:/ (x....

    When trying to go from Organizer to Editor, I receive a Ryntime Error.  It reads: Microsoft Visual C++ Runtime Error.    Runrime Error  Program c:\(x....

    I kept getting the same error message too! Thank goodness I'm not alone in this!

  • RUNTIME ERROR - Trying to INSERT dbtab FROM dynamic itab

    Hi guys,
    I'm trying to do this
    INSERT (l_nametab) FROM TABLE <dynamic_table>.
    where:
    DATA: l_nametab TYPE TABNAME VALUE 'PA0002'.
    FIELD-SYMBOLS: <dynamic_table> TYPE STANDARD TABLE.
    DATA: dy_table2 type ref to data.
    CREATE DATA dy_table2 TYPE STANDARD TABLE OF (l_nametab).
    ASSIGN dy_table2->* TO <dynamic_table>
    ... but I received this runtime error:
    DBIF_RSQL_INTERNAL_ERROR
    Internal error when accessing a table.
    The current ABAP/4 program terminated due to
    an internal error in the database interface.
    An internal error in the database interface occurred during access to
    the data of table "PA0002 ".
    The situation points to an internal error in the SAP software
    or to an incorrect status of the respective work process.
    For further analysis the SAP system log should be examined
    (transaction SM21).
    For a precise analysis of the error, you should supply
    documents with as many details as possible.
    Does anybody know how can it be solved?
    I'll really apreciate it.
    Thanks and Regards.

    Hi Max,
    How can I upload this data if I'm reading the info from an Input File.
    The FM HR_INFOTYPE_OPERATION is useless because the UNAME fild doesn't remain into the record. They really need these field.
    The main idea of these program is to read the Input File Line, wich can belong to any infotype.
    I'm already reading the Infotype data from the input file and I need to transfer it to the PAXXXX table.
    Next, a little explanation of it:
    This program is to INSERT DATA INTO HR TABLES...
    The FM HR_INFOTYPE_OPERATION is useless in this process...
    Only with INSERT dbtab it has to be done!!!
    1.- Read HR data from an input file. The data type of the file lines is PRELP.
    2.- Get the input file data into an internal table (TYPE PRELP) using the ABAP Method CL_GUI_FRONTEND_SERVICES=>GUI_UPLOAD.
    3.- Get the DDic. Table Name using CONCATENATE 'PA' wa_file-infty INTO l_nametab.
    4.- Get the DDic.Struct.Name using CONCATENATE 'P' wa_file-infty INTO l_nametype.
    5.- Assign values with the same code:
      FIELD-SYMBOLS: <dyn_table> type standard table,
                     <dyn_wa>,
                     <dyn_field>.
      FIELD-SYMBOLS: <dyn_table2> type standard table,
                     <dyn_wa2>,
                     <dyn_field2>.
      DATA: dy_table2 type ref to data,
            dy_line2  type ref to data.
      DATA: dy_table type ref to data,
            dy_line  type ref to data,
                CREATE DATA dy_table TYPE STANDARD TABLE OF (l_nametype).
                ASSIGN dy_table->* TO <dyn_table>.
                " Create dynamic work area and assign to FS
                CREATE DATA dy_line LIKE LINE OF <dyn_table>.
                ASSIGN dy_line->* TO <dyn_wa>.
                CREATE DATA dy_table2 TYPE STANDARD TABLE OF (l_nametab).
                ASSIGN dy_table2->* TO <dyn_table2>.
                " Create dynamic work area and assign to FS
                CREATE DATA dy_line2 LIKE LINE OF <dyn_table2>.
                ASSIGN dy_line2->* TO <dyn_wa2>.
    6.- Convert the Input File Line from PRELP type to PNNNN type with the ABAP method
          CL_HR_PNNNN_TYPE_CAST=>PRELP_TO_PNNNN            EXPORTING        PRELP  = wa_file
                                                                                    IMPORTING        PNNNN  = <dyn_wa>.
    7.- As <dyn_wa2> and <dyn_table2> are of PANNNN Data Type, there is an structure with the MANDT field to be assigned to it:
    " Type Definition
    TYPES: BEGIN OF type_mandt,
              mandt TYPE MANDT,
           END OF type_mandt.
    " Structure Definition
    DATA: wa_mandt TYPE type_mandt.
    " Structure value assignation
    wa_mandt-mandt = sy-mandt.
    8.- Assign corresponding values and INSERT INTO dbtab
              MOVE-CORRESPONDING <dyn_wa> TO <dyn_wa2>. "XXXX
              MOVE-CORRESPONDING wa_mandt TO <dyn_wa2>.
              APPEND <dyn_wa2> TO <dyn_table2>.
             INSERT (l_nametab) FROM TABLE <dyn_table2> ACCEPTING DUPLICATE KEYS.
    9.- In these code line, the menctioned runtime error appears.
    I hope it can be solved...
    Thanks and regards...

  • RUNTIME ERROR! While syncing contacts from 9900 to windows contacts

    BlackBerry Desktop Software Version :- 7.1.0.37
    BlackBerry Device Software Version :- 7.1 Bundle 1646 (v7.1.0.523, Platform 5.1.0.393)
    BlackBerry Device :- Bold 9900
    Windows 7
    While syncing contacts to and fro , from the device and windows contacts, experiencing the following Runtime Error :-
    ' Microsoft Visual C++ Runtime Library
    Runtime Error!
    Program: C:\Program ...
    This application has requested the Runtime to terminate it in an unusual way. Please contact the application's support team for more information. '

    Hi and Welcome to the Community!
    I don't find a specific KB that is exactly on point to your description...perhaps you will have better luck searching:
    http://btsc.webapps.blackberry.com/btsc/microsites/microsite.do
    Otherwise, I'd suggest this thread:
    http://supportforums.blackberry.com/t5/Desktop-Software-for-PC/Cleanly-quot-Starting-Over-quot-with-...
    It starts with a process for cleanly starting over, and there is some discussion, and there is also a post (15) with links to older Desktop Software versions, if those are needed. Note that this is not, by any means, guaranteed to work...but it has worked for many to resolve issues they are having.
    Good luck!
    Occam's Razor nearly always applies when troubleshooting technology issues!
    If anyone has been helpful to you, please show your appreciation by clicking the button inside of their post. Please click here and read, along with the threads to which it links, for helpful information to guide you as you proceed. I always recommend that you treat your BlackBerry like any other computing device, including using a regular backup schedule...click here for an article with instructions.
    Join our BBM Channels
    BSCF General Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Portal Runtime Error while executing GP tasks from UWL

    Hi all,
    I am trying to create a process in Guided Procedures.
    The activities involved in this process include calling some standard R/3 transactions.
    For this, I first created Portal Iviews of the SAP R/3 transactions involved. Then In GP Design time, I created corresponding callable objects of type Portal Iviews.
    User's can view the tasks assigned to them in their UWL without any problems. To execute a particular task, user clicks on the corresponding Work item in UWL.
    However, this gives a portal runtime error.
    The log file has the following error.
    com.sap.portal.prt.runtime#sap.com/irj#com.sap.portal.prt.runtime#LAAJ#9176##LTIVSH01.vshodc_LP1_11774250#LAAJ#4474b4ce1db811ddba24001871775ce5#SAPEngine_Application_Thread[impl:3]_33##0#0#Error##Java###04:38_09/05/08_0046_11774250
    [EXCEPTION]
    #1#com.sapportals.portal.prt.runtime.PortalRuntimeException: Exception in SAP Application Integrator occured: Unable to parse template &\#39;<System.ConnectionString>&\#39;; the problem occured at position 0. Cannot process expression <System.ConnectionString> because Invalid System Attribute:
    System: &\#39;SAP_LocalSystem&\#39;,
    Attribute: &\#39;ConnectionString&\#39;.
    Please suggest a solution for this problem.
    Regards,
    Preksha

    Dear Friends
    I have the same with this problem
    Please help us to resolve this problem
    Thanks and best regards

  • Runtime Error in VL01N after upgrade from 4.6c to ECC 6.0

    hi, 
       We are doing a upgrade project from 4.6c to ECC 6.0 and when we are running the VL01n tcode and as soon as we hit enter in easy access screen its throwing a runtime error as " The key of internal table "XLIPS" contains components of type  'X' or "XSTRING". The "READ TABLE XLIPS" statement is not permitted for such tables in a unicode context'. The xlips is declared as:
    DATA: BEGIN OF XLIPS OCCURS 15.
    INCLUDE STRUCTURE LIPSVB.
    DATA: END OF XLIPS.
    so i have checked the lipsvb structure in that i dont find the key fields of type X or XSTRING all are of type CHAR 4. this LIPSVB is the Reference structure for  XLIPS and YLIPS.
    THANKS IN ADVANCE.

    Please  see the  Patch level of the  SD, FI ,etc...
    and  apply  it   the basis   should   find  it  out  .... for  ECC6.0   then  minimum level  of  patches  should  be   upgraded.
    please  ,login to help.sap.com  ... there  in the  search  see the  document   of the pateches  for the   ECC6.0 for SD & FI ... like wise  for  all  Modules  ....
    Reward  points if it is usefulll ...
    Girish

  • Runtime Error in MIGO after upgrade from 4.6c to ECC 6.0

    hi,
        We are doing a upgrade project from 4.6c to ECC 6.0 and when we are posting the MIGO a runtime error is occuring from the method
    "IF_EX_MB_DOCUMENT_BADI~MB_DOCUMENT_BEFORE_UPDATE" which is
    in the class "ZCL_IM_MMIM_STK_TRANSFER".
    The error is as follows :
    method IF_EX_MB_DOCUMENT_BADI~MB_DOCUMENT_BEFORE_UPDATE
    >>>>>CALL FUNCTION 'Z_MM_STK_TSFR'  
    TABLES     
    T_XMKPF = XMKPF
    T_XMSEG = XMSEG.  
    END METHOD.
    the errror is showing at function  'Z_MM_STK_TSFR'   .
    I would be happy if anyone could give any inputs i hav also put chek in unicode in attributes in main program however still the error is arising.
    thanks in advance

    hi,
         thanks for the inputs i have done the syntax check on the main program and the FM the error which is coming is Field "ENJPREVIEW" is unknown. its neither in one of the specified tables nor defined by a DATA 'statement' . THis error is showing in the include LMEDRUCKF1K.
    Thanks in advance

  • Getting a runtime error in reading long text from production order

    Hi all,
    I am trying to read production order long text and the code is not showing any syntax error but if i execute it i am getting a runtime error as "Text object aufk is not available".
    But i did check for the text object , text id enties in TTXOB and TTXID tables. Also i am able to see the relevant text in tables STXH and STXL, dont know why i am getting this runtime error and unable to debug.
    I tried a lot searching in forums, but they all ask me to write the code in the way i did, so dont know what is the problem.
    Data Declarations
    data: xaufk  type aufk.
    data: l_name type thead-tdname.
    data: ilines type table of tline with header line.
    Parameters
    parameters: p_aufnr type aufk-aufnr.
    concatenate sy-mandt p_aufnr into l_name.
    condense l_name no-gaps.
              CALL FUNCTION 'READ_TEXT'
                EXPORTING
                 CLIENT                         = SY-MANDT
                  ID                                =  'kopf'
                  LANGUAGE                 =  sy-langu
                  NAME                          = l_name
                  OBJECT                       = 'aufk'
                TABLES
                  LINES                         =  ilines
              write : ilines.
    Regards
    Jessica

    Hey Vijay,
    Thanks for you reply, It worked, i am not getting the runtime error, but also not getting the output.
    am i missing anywrite statements?
    Please check the code and suggest changes if required. i want to see the long text in the production order in the output. should i say write: ilines.?
    Data Declarations
    data: xaufk  type aufk.
    data: l_name type thead-tdname.
    data: ilines type table of tline with header line.
    Parameters
    parameters: p_aufnr type aufk-aufnr.
    concatenate sy-mandt p_aufnr into l_name.
    condense l_name no-gaps.
              CALL FUNCTION 'READ_TEXT'
                EXPORTING
                 CLIENT                         = SY-MANDT
                  ID                            = 'KOPF'
                  LANGUAGE                      =  sy-langu
                  NAME                          = l_name
                  OBJECT                        = 'AUFK'
                TABLES
                  LINES                         =  ilines
                 write : ilines.
    Regards,
    Jessica.

  • Runtime error encounter when getting instance from ResourceFactory

    Hi,
       I'm developing a IView report on the documents' status in the repository, but i have encounter the following runtime error when I get an resource instance from the ResourceFactory,
    <i>Portal Runtime Error
    An Exception occurred while processing a request for:
    IView: N/A
    Component: N/A
    com/sapportals/wcm/repository/IResourceFactory</i>
    My codes are as follows:
    <i>IResourceFactory factory = Resourcefactory.getInstance()</i>
    I try to catch the ResourceException(), but an similar runtime error occured. I'm using PDK EP 6.0_60.2.2
    Thanks for any suggestions/solutions provided.

    Hi,
    did you set the SharingReference attribute in portalapp.xml to "knowledgemanagement, usermanagement" ?
    Best regards,
    Thilo

  • Encountering a RunTime error when I try running from command prompt

    When I try to load my class from the command prompt I get the error:
    Exception in thread "main" java.lang.NoClassDefFoundError: MiniTriangle
    Since this seems like a pretty basic error, I'm hoping there's a black and white solution to it. Unfortunatly I don't have the slightest idea what that might be.
    Any help would be appreciated, thanks in advance!!!

    I'm pretty new to this myself but have encountered this error before. I've found it happens when you try to run the programme and the class name isn't the same as the file name. So if you named the text file when you wrote the code MiniTriangle when you compile it you will get a file called MiniTriangle.class which is what you are trying to run. However if you inadvertently misspelled the class definition in the code and entered say
    class MiniTringle {
    you would get the error you are experiencing when you try to run MiniTriangle.class
    Hope this helps

  • Runtime error in updating initialization data from ODS in to an Infocube

    Hi experts,
    i have uploaded the init request in to an ODS.Now when i am trying to update this init request by selecting <b>Update ODS Data in to data target</b> fron the context menu of ODS I am getting Short dump saying:
    MESSAGE_TYPE_X" C
    SAPLRSSM" or "LRSSMU36"
    RSSM_OLTPSOURCE_SELECTIONS.
    furthermore as i am udating data from an ODS to infocube,  would the esource system be my BW system it self.
    Please help me ASAP.
    Thanks in advance.
    Jitendra Joshi

    hi Jagdeesh,
    thanks for your help.it has probably solved the problem i was previously facing but now when i am trying to schedule the update , it is getting faild along with following error message:
    The InfoSource 80FIGL_O02 specified in the data request, is not defined in the source system.
    the system suggest following solution :
    In the Administrator Workbench of the Business Information Warehouse, update the metadata for this source system, and delete the InfoPackages belonging to InfoSources that no longer existing .
    I tried it by replicating datasource but it has not solved the problem.
    Please Help ASAP.
    i have assigned point to for the solution  you gave...........
    Thanks in advance
    Jitendra Joshi

  • FRM-92101-Did any one migrate to 10GR2 from Forms 6 generated by Designer 6

    I am using designer 6 PLLs . We are migrating to 10GR2; Recompiled all plls in 10GR2 and it is throughing FRM92101 for all Tabbed forms. Upon debugging it is breaking at the OFGTAB.pll.
    Any help is appreciated!
    Thanks.

    oops!!
    Kindly excuse me i totally missed the error code.
    Did you compare designer plls for 10GR2 designer?
    It is possible that some procedures/packages are obsolete.
    I would recommend to use 10g Designer plls.
    Cheers
    AT

Maybe you are looking for

  • Not able to closing the maintenance cycle of charm

    Hi Team I am not able to close the maintenance cycle of charm. I had already tried with the phase utility report, I had checked my all authorizations and it is fine. I had gone through most of SCN queries for same, current phase of project cycle is c

  • IS-U: ABAP Objects or Classic?

    Hi all, I have a general question regarding programming in IS-Utilities: I have to develope some reports on BUT100, FKKOP, etc. and someone told me that for performance reasons the program should be developed in traditional ABAP and not using methods

  • Actionscript, displaylist rendering and stage3d rendering not showing up

    Hi, I'm using flash builder 4.7, with overlayed the air sdk 3.5. I'm working on a desktop adobe air project with away3d. WIndows 7 64 bit business. I enable the telemetry tick in the flash builder compiler options. But when Scout runs the thre tabs a

  • Patch 119059-40 cannot be downloaded

    Patch 119059-40 cannot be downloaded. I get recommendations to install this patch on six different hosts. When I run "smpatch update -i 119059-40", I get the message:

  • Features in SD module

    Hi Team, Am new in SD module could you pls share some of the functions available in SD module.. same like product interchangeability process? For sure this will help us implement new methods in our process. Thanks, Vijesh