FSIS host controller service getting stopped frequently on windows 2008 machine

We have 6 Windows hosts out of which 1 is admin node for FSIS and other 5 have IMS instances running. Of late we observed that FSIS host controller service is getting stopped on many of these windows hosts almost every day and sometimes 5-6 times a day.
From the event viewer we could not find much errors except messaging saying FSIS host controller service got terminated unexpectedly. below are the message from one of the host controller service log. I have enabled debug mode today so waiting for debug logs
to give some more information
2013-01-29T20:07:55.3371746-08:00 Warning [11] WcfReplicationManager - Exception in replication handler, backing off for 300 seconds
System.ServiceModel.EndpointNotFoundException: Could not connect to net.tcp://srch-fsis-001-p.cisco.com:17001/ceres/hostcontroller/nettcp. The connection attempt lasted for a time span of 00:00:00.9961320. TCP error code 10061: No connection could be made because
the target machine actively refused it 72.163.42.208:17001.
Server stack trace:
   at System.ServiceModel.Channels.SocketConnectionInitiator.Connect(Uri uri, TimeSpan timeout)
   at System.ServiceModel.Channels.BufferedConnectionInitiator.Connect(Uri uri, TimeSpan timeout)
   at System.ServiceModel.Channels.ConnectionPoolHelper.EstablishConnection(TimeSpan timeout)
   at System.ServiceModel.Channels.ClientFramingDuplexSessionChannel.OnOpen(TimeSpan timeout)
   at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
   at System.ServiceModel.Channels.ServiceChannel.OnOpen(TimeSpan timeout)
   at System.ServiceModel.Channels.CommunicationObject.Open(TimeSpan timeout)
   at System.ServiceModel.Channels.ServiceChannel.CallOnceManager.CallOnce(TimeSpan timeout, CallOnceManager cascade)
   at System.ServiceModel.Channels.ServiceChannel.EnsureOpened(TimeSpan timeout)
   at System.ServiceModel.Channels.ServiceChannel.Call(String action, Boolean oneway, ProxyOperationRuntime operation, Object[] ins, Object[] outs, TimeSpan timeout)
   at System.ServiceModel.Channels.ServiceChannelProxy.InvokeService(IMethodCallMessage methodCall, ProxyOperationRuntime operation)
   at System.ServiceModel.Channels.ServiceChannelProxy.Invoke(IMessage message)
Exception rethrown at [0]:
   at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
   at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
   at Microsoft.Ceres.HostController.WcfTypes.IRepositoryVersionManagement.GetRepositoryGuid()
   at Microsoft.Ceres.HostController.WcfServer.WcfReplicationManager.get_PrimaryRepositoryGuid()
   at Microsoft.Ceres.HostController.Repository.Replication.ReplicationManager.ReplicationHandler()
System.Net.Sockets.SocketException: No connection could be made because the target machine actively refused it 72.163.42.208:17001
   at System.Net.Sockets.Socket.DoConnect(EndPoint endPointSnapshot, SocketAddress socketAddress)
   at System.Net.Sockets.Socket.Connect(EndPoint remoteEP)
   at System.ServiceModel.Channels.SocketConnectionInitiator.Connect(Uri uri, TimeSpan timeout)
2013-01-30T07:55:05.1432766-08:00 Info    [5] ServiceRunner - Starting host controller service
2013-01-30T07:55:05.1921066-08:00 Info    [5] ServiceRunner - Machine Configuration:
    Machine Name          : SRCH-FSIS-006-P
    Operating System      : Microsoft Windows NT 6.1.7601 Service Pack 1
    Runtime Version       : v2.0.50727
2013-01-30T07:55:05.2057790-08:00 Info    [5] ServiceRunner - Service Configuration:
    Log Level             : Info
    Log Max FileSize      : 1 GB
    Log Max Log Volume    : 100 GB
    Log Retention Period  : 40320 minutes
    Log Rotate Daily      : True
    Log Rotate Hour of Day: 0
    EventLog Source       : FSIS Host Controller
    EventLog Level        : Info
    Runtimes              : C:\Program Files\FAST Search Server 2010 for Internet Sites\Runtime\
    Repository Path       : C:\Users\fsis.gen\AppData\Local\FSIS\Repository\
    Replicated From       : net.tcp://srch-fsis-001-p.cisco.com:17001/ceres/hostcontroller/nettcp
    Node Path             : C:\Users\fsis.gen\AppData\Local\FSIS\Nodes\
    Node Port Allocation  : Start = 17002, End = 17199, Block Size = 20
    Node Memory Limit     : Soft = 70%, Hard = 80% of installed physical memory
    On Shutdown           : Teminate all nodes
2013-01-30T07:55:05.4196544-08:00 Info    [5] RepositoryManager - Initializing repository
2013-01-30T07:55:05.7399792-08:00 Info    [5] RepositoryManager - Initializing repository journal
2013-01-30T07:55:05.9519014-08:00 Info    [5] HostController - 16383 MB physical memory installed
2013-01-30T07:55:05.9538546-08:00 Info    [5] HostController - 13106 MB physical memory available for nodes
2013-01-30T07:55:06.1716364-08:00 Info    [5] ServiceRunner - Repository being replicated from the primary repository at net.tcp://srch-fsis-001-p.cisco.com:17001/ceres/hostcontroller/nettcp
2013-01-30T07:55:06.4118800-08:00 Info    [5] ServiceRunner - Service available at
http://srch-fsis-006-p:17000/ceres/hostcontroller
2013-01-30T07:55:06.4128566-08:00 Info    [5] ServiceRunner - Service available at net.tcp://srch-fsis-006-p:17001/ceres/hostcontroller
2013-01-30T07:55:06.4206694-08:00 Info    [5] WcfReplicationManager - Replication manager started
2013-01-30T10:05:08.2641940-08:00 Warning [12] HostController - Failed to determine if the node running [System = Fsis, Node = InteractionEngineNode42]
System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation.
   at System.RuntimeMethodHandle._InvokeMethodFast(Object target, Object[] arguments, SignatureStruct& sig, MethodAttributes methodAttributes, RuntimeTypeHandle typeOwner)
   at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture, Boolean skipVisibilityChecks)
   at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture)
   at System.RuntimeType.InvokeMember(String name, BindingFlags bindingFlags, Binder binder, Object target, Object[] providedArgs, ParameterModifier[] modifiers, CultureInfo culture, String[] namedParams)
   at Microsoft.Ceres.HostController.Controller.RuntimeProxy.InvokeControllerMethod(String method, Object[] args)
   at Microsoft.Ceres.HostController.Controller.RuntimeProxy.IsNodeOperating(String nodeRoot)
   at Microsoft.Ceres.HostController.Controller.RuntimeProxy.IsNodeOperating(String nodeRoot)
   at Microsoft.Ceres.HostController.Controller.HostController.IsNodeOperating(String systemName, String nodeName)
System.ArgumentException: A node is not deployed at C:\Users\fsis.gen\AppData\Local\FSIS\Nodes\Fsis\InteractionEngineNode42
   at Microsoft.Ceres.CoreServices.Deployment.DeploymentController.ValidateDeployed(String nodeRoot)
   at Microsoft.Ceres.CoreServices.Deployment.DeploymentController.IsNodeOperating(String nodeRoot)

Hello,
The answer for this is in the error message:
2013-01-29T20:07:55.3371746-08:00 Warning [11] WcfReplicationManager - Exception in replication handler, backing off for 300 seconds
System.ServiceModel.EndpointNotFoundException: Could not connect to net.tcp://srch-fsis-001-p.cisco.com:17001/ceres/hostcontroller/nettcp. The connection attempt lasted for a time span of 00:00:00.9961320. TCP error code 10061:
No connection could be made because the target machine actively refused it 72.163.42.208:17001
Verify that you have connectivity from this server to server 72.163.42.208 in port 17001.
You can test this with telnet:
telnet 72.163.42.208 17001
You can check the documentation for the list of ports used by SharePoint @
http://technet.microsoft.com/en-us/library/cc262849.aspx
Cheers

Similar Messages

  • Exchange 2013 The Microsoft Exchange Search Host Controller service terminates

    Hi Folks,
    at our Exchange Server ( Version 15.0 (Build 775.38 / 0.1 (8.0.535.0 ) we found over 200k entrys / day saying that:
    The Microsoft Exchange Search Host Controller service terminated unexpectedly.  It has done this 193270 time(s).  The following corrective action will be taken in 30 milliseconds: Restart the service.
    The Command:
    Get-MailboxDatabaseCopyStatus | fl 'Content*'
    shows the following:
    ContentIndexState            : Failed
    ContentIndexErrorMessage     : An internal error occurred for the database or its index
    ContentIndexVersion          :
    ContentIndexBacklog          :
    ContentIndexRetryQueueSize   :
    ContentIndexMailboxesToCrawl :
    ContentIndexSeedingPercent   :
    ContentIndexSeedingSource    :
    i investigated a bit further:
    RunspaceId                            : 06d7b8f6-969f-47f8-89ba-87b2fed639bb
    Identity                              : db_1\exch1
    Id                                    : db_1\exch1
    Name                                  : db_1\exch1
    DatabaseName                          : db_1
    Status                                : Healthy
    InstanceStartTime                     : 14.10.2014 21:03:38
    LastStatusTransitionTime              : 14.10.2014 21:03:45
    MailboxServer                         : exch1
    ActiveDatabaseCopy                    : exch2
    ActiveCopy                            : False
    ActivationPreference                  : 1
    StatusRetrievedTime                   : 15.10.2014 13:36:52
    WorkerProcessId                       : 2076
    ActivationSuspended                   : False
    ActionInitiator                       : Unknown
    ErrorMessage                          :
    ErrorEventId                          :
    ExtendedErrorInfo                     :
    SuspendComment                        :
    RequiredLogsPresent                   :
    SinglePageRestore                     : 0
    ContentIndexState                     : Failed
    ContentIndexErrorMessage              : An internal error occurred for the database or its index
    ContentIndexVersion                   :
    ContentIndexBacklog                   :
    ContentIndexRetryQueueSize            :
    ContentIndexMailboxesToCrawl          :
    ContentIndexSeedingPercent            :
    ContentIndexSeedingSource             :
    CopyQueueLength                       : 0
    ReplayQueueLength                     : 0
    ReplaySuspended                       : False
    ResumeBlocked                         : False
    ReseedBlocked                         : False
    MinimumSupportedDatabaseSchemaVersion : 0.121
    MaximumSupportedDatabaseSchemaVersion : 0.126
    So i read that the Database is OK, but the Index is broken somewhow ?
    I`ve read somewhere that i should delete the GUID Folder and restart the Hostcontroller service, can somebody explain HOW to do this ? where can i Find the GUID Folder ? Is it the correct way to solve this problem ?
    thx in advance!

    Hi,
    after i removed the suggested Folder, i disabled both "Microsoft Exchange Search service and Microsoft Exchange Search Host Controller service, than i restarted the Exchange Server.
    After that i restarted both services.
    Sadly nothing has changed, hostcontroller.exe is still crashing:
    The Microsoft Exchange Search Host Controller service terminated unexpectedly.  It has done this 153 time(s).  The following corrective action will be taken in 30 milliseconds: Restart the service.
    The sequence is like this:
    First the Search controller starts:
    Search HostController Starts: Service started successfully.
    After that the hostcontroller crashes:
    .NET Runtime: Application: hostcontrollerservice.exe
    Framework Version: v4.0.30319
    Description: The process was terminated due to an unhandled exception.
    Exception Info: Microsoft.Ceres.HostController.Controller.HostControllerException
    Stack:
       at Microsoft.Ceres.HostController.WcfServer.WcfService.StartService()
       at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
       at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
       at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object)
       at System.Threading.ThreadHelper.ThreadStart()
    Than we get this Application Error:
    Application Error:
    Faulting application name: hostcontrollerservice.exe, version: 16.0.775.0, time stamp: 0x5211bea8
    Faulting module name: KERNELBASE.dll, version: 6.2.9200.16864, time stamp: 0x531d34d8
    Exception code: 0xe0434352
    Fault offset: 0x0000000000047b8c
    Faulting process id: 0x2a08
    Faulting application start time: 0x01cfe90eb249f511
    Faulting application path: C:\Program Files\Microsoft\Exchange Server\V15\Bin\Search\Ceres\HostController\hostcontrollerservice.exe
    Faulting module path: C:\Windows\system32\KERNELBASE.dll
    Report Id: f2351e08-5501-11e4-940b-00155d203202
    Faulting package full name:
    Faulting package-relative application ID:
    So if anybody can help - feel free!

  • OC4J as a service getting stopped

    Hi,
    We made OC4J as a service but the service is getting stopped for every 2 days. Where can I check the log for this...
    What are the changes I need to make to keep it running continously..
    Thanks

    Hi I used the following command to make it as a service
    "C:\Program Files\JavaService\javaservice.exe" -install "Oracle BI OC4J Server" "C:\Program Files\Java\jre1.5.0_11\bin\client\jvm.dll" -XX:MaxPermSize=128m -Xmx512m "-Djava.class.path=C:\OracleBI\oc4j_bi\j2ee\home\oc4j.jar" -start oracle.oc4j.loader.boot.BootStrap -description "Oracle BI Oc4J Service"
    I think this doesnt have a log ..
    Please guide me..

  • HOST APP SERVICE has stopped working

    I keep getting the message "HOST APP SERVER has stopped working" whenever I try to select the home button on my screen. It simply says that Windows will close the application and notify me when a solution has been found, but this has been going
    on for a week and it has yet to message me a solution. The error message isn't very specific as to what is going on and I have no idea what to do!

    Hi kgabriella,
    Please open Event Viewer and check the related logs, if possible, post the information here.
    Further, follow the advice posted by Arnav Sharma, follow the guide to boot into clean boot and check the issue again.
    Besides, see if the thread below would help:
    Catalyst control centre host has stopped working.
    Best regards
    Michael Shao
    TechNet Community Support

  • Ricoh memory stick host controller version 6.3.x for windows 7

    hi
    i have a dv 9000 series computer with vista x64 and the windows 7 ugrade advisor tell me i have only the  ricoh memory stick host controller driver not compatible
    i have the version 6.1 but i need the 6.3.x version
    i can't find that
    anyone can help me plz for finding this driver
    i see in this link
    http://www.pcpitstop.com/drivers/download/Ricoh~Me​mory~Stick~Host~Controller.html
    the driver but we have no link for downloading
    thanks

    I just ended up using the Vista (64-bit) driver provided on the dv9000 support webpage and everything seems to work fine.

  • SAP Backup Service  SAP 8.8 and Windows 2008 R2 64 Bit

    Dear All ( Mr Gordon)
    I am facing problem with the Backup Service on windows 2008 R2 64 Bit.
    1)The Service starts - There is no Issue
    2)THere is no Backup - Even though i schedule it perform the backup
    3)EvenLog has a lot of messages -   Messages says some Dll are Missing or Corrupt.
    COmpletely Uninstalled the Server Tools and Reinstalled back ,still there is error.
    PLease help !
    Best Regards
    Dayal

    Dear Dayal,
    Thank you for your trust on me. To be honest, I never use SAP Backup Service. This is because: SQL Server provides its own Backup Service. No other vendor can compete with its build in function.
    Thanks,
    Gordon

  • How to Upgrade Service Manager 2012 SP1 with Windows 2008 R2 to SCSM 2012 R2 with Windows 2012 R2

    Hi,
    We are using Service Manager 2012 SP1 UR2 with Windows 2008 R2.
    I am planning to upgrade Service Manager to R2 with Windows 2012 R2. I found the steps to upgrade SCSM 2012 Sp1 to R2 but need assistance to upgrade with 2012 R2 OS.
    Please suggest how to achieve the above mentioned objective.
    Regards, Syed Fahad Ali

    Virtualization solves this problem handily, by allowing you to create a new server to run the new program on the same hardware. it also solves the related problem of moving off unsupported hardware without changing OS or application. VMware is my personal
    favorite, but Hyper-V, Xen, and VirtualBox all have similar capabilities.
    Compare the cost of work and confidence in success of a upgrade, where any of thousands or millions of uncontrolled settings could cause an issue, to the cost of work and confidence in success of installing a new OS instance and configuring a known state
    for the new environment.
    In short, upgrades should no longer be a thing. there are just too many ways they can go wrong, and it's far too easy to create a new OS with minimal expense and effort.

  • HP OM : OVepmessageactionserver service gets stopped every time we try to restart it

    Hi,
    We have OMW ver 9.00.00231 installed in windows 2k8 server. I got an error while I was working with LogFile monitoring policy. I am attaching the error below:
    "Faulting application OvEpMsgActSrv.exe, version 6.0.94.34, time stamp 0x50f6e141, faulting module ntdll.dll, version 6.0.6002.18881, time stamp 0x51da3d16, exception code 0xc0000005, fault offset 0x0000000000048f12, process id 0xcf8, application start time 0x01cf8f98fe24a8c1."
    I restarted the system since I had the error saying that the management server was unable to forward the messages as email, since then I am unable to login to the console. The ovepmessagesActionServer service
    and the OvepstatusEngine service starts and stops immediately.
    FYI, I have done the below activites to make the server up (seeing similar forums):
    1) When I restarted the server there was windows updates happening which I removed later on all the patches that were updated during the restart.
    2) We didn't install any hotfix on the management server since last year and this issue we are facing for the very first time, even doing nothing on the server
    3) I have executed the below steps too:
    vpstat -3 -r stop
    net stop winmgmt
    vpstat -3 -r start
    vpstat -3
    vpstat -p
    4) As given in a forum, in the sql database (openview) I have executed the below query:
    select count (*) from ov_ms_keyrelationcache where messageid not in (select
    id from ov_ms_message);
    if it's value is more than 0 ,delete is using :-
    delete from ov_ms_keyrelationcache where messageid not in (select id from
    ov_ms_message);
    5) Also executed,
     -  truncate table OV_MS_Message
    - truncate table OV_MS_Annotation
    - truncate table OV_MS_KeyRelationCache
    But of no use till now, expecting your help asap..
    Regards,
    Saravanan.M

    HP all-in-one 6500A has worked fine until this afternoon.  Now I am getting Paper size mismatch error message.  Uninstalling and reinstalling driver did not help.

  • Host process for windows services has stopped working in windows server 2008

    hi ..
    i can access to server from any where by remote desktop
    the problem is if you want access the error in client is can not connect to user profile and in server the error is (failed to connect to windows service
    windows could not connect to user profile service service .. )

    This one may help.
    You receive a "The User Profile Service failed the logon” error message
    Regards, Dave Patrick ....
    Microsoft Certified Professional
    Microsoft MVP [Windows]
    Disclaimer: This posting is provided "AS IS" with no warranties or guarantees , and confers no rights.

  • No method (within view controlle) to get reference to the window controller

    Hello all,
    I need to fire the exit plug of the window controller out of an embedded view.
    All help I can find in the internet tell me to "easily" get a ref to the window controller and thus to fire its plug as follows:
    data: L_REF_MAIN_WINDOW type ref to IG_MAIN_WINDOW .
    L_REF_MAIN_WINDOW =   WD_THIS->GET_MAIN_WINDOW_CTR( ).
    L_REF_MAIN_WINDOW->FIRE_MY_EXIT_PLUG_PLG(  ).
    But my view-controller dos not implement a method like
    GET_MAIN_WINDOW_CTR( )
    How can I get this method generated? What am I doing wrong?
    Thanks for your replies.
    Edited by: iSD1977 on Aug 23, 2011 4:09 PM

    Hello,
    in the Properties tab of the View Controller, add Window Controller as Used Controller.
    BR, Saravanan

  • How do I stop frequent configuring windows update?

    I have a personal Computer and observing  recently it is configuring windows updates frequently.It is very annoying for me and I want to get rid from this problem.For your information I am using Windows 7 Professional.
    Thanks

    You're in luck. Windows 7 updates can involve quite a few files to download and install, but as of yesterday, full support of Windows 7 is over. You'll still get some security updates but feature updates are finished. That should ease the problem. Of course, you can turn off automatic updates completely, as long as you're not concerned about security issues.

  • MobileMe Services has stopped working in Windows.

    Hi
    After I updated iTunes to 11.1.4.62, then a few problems appeared. When the update was finish a .dll file was missing, so I had to uninstall iTunes and all other programs and services to make it work again. But after that and what is wrong now is the MobileMe add-in when I'm starting up Microsoft Outlook 2010.
    I appreciate any help. This is the problem details and I don't know exactly what I can do to fix it.
    Problem signature:
      Problem Event Name:          APPCRASH
      Application Name:          MobileMeServices.exe
      Application Version:          1.6.65.0
      Application Timestamp:          4cafa71a
      Fault Module Name:          kernel32.dll
      Fault Module Version:          6.0.6002.18005
      Fault Module Timestamp:          49e037dd
      Exception Code:          c06d007e
      Exception Offset:          0003fbae
      OS Version:          6.0.6002.2.2.0.256.1
      Locale ID:          1033
      Additional Information 1:          ef22
      Additional Information 2:          066084566954155364c4268f67b734ef
      Additional Information 3:          5673
      Additional Information 4:          7135fc18150805302d952cd2d41e1e3f
    Read our privacy statement:
      http://go.microsoft.com/fwlink/?linkid=50163&clcid=0x0409

    turingtest2 wrote:
    MobileMe is a discontinued service and the control panel should be removed if still present. Not doing so could cause Microsoft Outlook to freeze and/or issue error messages. See HT2992: MobileMe: Uninstalling the MobileMe Control Panel for Windows for details.
    tt2
    Information on time, but ok thanks anyway! It has already been done since I got suggestions from another person in the Apple community forum.

  • Getting Mac Address of Windows 7 Machine

    Hi all,
    Our application used to gather the Mac address of the client machine. For this purpose, i was using the Java bean(ClientInfos.fmb) to get the information. It used to work fine until
    the OS was Windows XP. As soon as the Windows 7 has come, the application/java bean could not collect the mac address.
    Pls let me know if there is any working for this problem.
    Even if there is any other alternative, I would love to adopt.
    One of the solution, I was thinking that to run a client_host command using webutil, write the output in a notepad. Get the mac address from the notepad.
    If it is possible, give me some clue,so that i can fight it down.
    Thanks & Regards,
    Alok Dubey

    There are likely several ways to accomplish this. You will need a custom java bean or webutil. WebUtil does not have a built-in function that can do what you want, but it will give you access to the system and/or registry. The problem with which you are faced is that some machines may have more than one net adapter and therefore more than one mac. Anyway.... you can use the CLIENT_HOST command to execute this Windows command:
    GETMAC*
    You can also execute GETMAC /NH+ and the data will be displayed without the column headers. If you write this info to a temp text file on the client, you can then read it with CLIENT_TEXT_IO. Use the pl/sql substr function to exact whatever part of the info you want to use.
    More info about the above command can be found on the MS website here:
    http://technet.microsoft.com/en-us/library/bb490913.aspx

  • LSI 1394 OHCI Compliant Host Controller driver for Windows 8.1

    I have an HP Z600 with a LSI 1394 OHCI Compliant Host Controller and get an error. It is a "This device cannot start. (Code 10) STATUS_DEVICE_POWER_FAILURE error
    When Windows 7 is installed, there is no error but with Windows 8.1 running there is this error.
    There are no installed legacy drivers that I can use and I have tried many different permutations of driver installs.
    Any thoughts?
    Thank you in advance.
    Sal

    Hi:
    You may also want to post your question on the HP Business Support Forum -- z Workstations section.
    http://h30499.www3.hp.com/t5/Workstations-z-series​-xw-series/bd-p/bsc-272#.VIMqRDh0zGg
    If you tried manually installing the W7/W8 driver (I have no clue which one of the several LSI drivers listed that you need), then that would have been the only suggestion I could have offered.

  • Oracle SID 102TNSListener stops frequently

    Hi All,
    Recently we installed Oracle 10.2.0.2.0.
    Now we observe that Oracle<SID>102TNSListener service is stopping frequently.
    We read below application error in event log:
    Faulting application TNSLSNR.EXE, version 0.0.0.0, faulting module oranl10.dll, version 10.2.0.1, fault address 0x000232ba.
    Can anyone tell us how we can resolve this problem.
    Thank you.
    Prashanth.R.G.

    If you have Metalink support read article "TNS LISTENER (10GR2 WIN32) CRASHES DUE TO MEMORY FAULT IN MODULE ORANL10.DLL" document number 5214373 and see if that applies.
    I would suggest upgrading to 10.2.0.3 or higher as the fix is listed in 11.1 and the bug reports lists only one customer as hitting the bug but the report is from Jan. 2007.
    Restarting the listener seems to be the suggested action.
    HTH -- Mark D Powell --