Hetis 945-E, no POST
Hello,
I have an MSI Hetis 945-E, motherboard MS-7231 ver4.0.
I am using an E7400 CPU (FSB 1066) and a Kingston KVR667D2N5/2G RAM module.
The system fails to reach POST, although the power LED lights and the fans start.
CPU and RAM has been tested in another MB and work OK.
I have also connected a 450W PSU instead of the standard one but still no POST.
There are also no beeps from the built-in speaker.
Should I try another CPU, eg. an E5300, or another RAM module?
What else should I try?
Thank you in advance!
The CPU used its not in the QVL list:
http://eu.msi.com/index.php?func=prodcpusupport&maincat_no=134&prod_no=1117#menu
Quote
Should I try another CPU, eg. an E5300, or another RAM module?
Yes to both, [The CPU is main suspected].
The E5300 is also not in the list.
Stick/use the CPU from the QVL list
Similar Messages
-
I am using a Hetis 945 (MS-6410) Barebone System as an Embedded Print Controller with a Touch Screen Monitor. I get a No Keyboard Error at boot up when no keyboarsd is connected. I can't find any keyborad settings within the Bios (Award Ver 6.00PG). How can I disable the keyboard?
Have a look in BIOS settings, under 'Standard CMOS settings', there is usually a 'Halt On...' option, which you should be able to change to 'No Errors'.
-
Paypal is duplicating on EVERY photo in my galery - help!!! Please!!!
I am a photographer looking to sell my photos through the web site I created on IWeb using Paypal. Here is my problem, I will give you an example:
Your at my home page.
You choose the Gallery/Web Page "Belgium"
Inside "Belgium" you pick the gallery named "Antwerp".
The 1st photo is called "Het Steen"
When I post my PayPal web widget of "ADD TO CART" and named the photo "Het Steen" in PayPal. It posts to ALL the other 25 photos inside the Antwerp Gallery. So, if someone bought "Het Steen" or "Main Square" or any other photo I have listed, I wouldn't be able to tell the difference b/c it duplicates the same "Add to Cart" button on every photo.
I thought I would be clever and add a field entitled: "Item Number" so I would know what the customer is buying no matter where they are. BUT if you put item number "101" ... it then copies "101" to 25 of the other photos listed in Antwerp.
How do I get this to stop??? I need help! Anyone know how to stop the duplication or is IWeb built this way and is there NO way to cure it????Things I have tried:
I have inserted a paypal button in the area below the photo. The problem with that is that it puts the PayPal entries on top of the enlarged photo of the gallery. Not only that but lets pretend you buy photo 111. Once you choose 111. It duplicates 111 to all the other photos in the gallery. If the customer forgets to insert the new number, I may think they want two copies of 111, but in reality they bought 111 and 115.
I have also tried creating numerous links to a PayPal page assigning just that paypal link to the specific photo...it still duplicated the same problem.
The reason I have a lot of photos on my gallery is for 2 reasons. One is to sell them and the other is b/c I help people ALL of the time to plan their trips. Which is always the question, "What should we see, what shouldn't be missed?".
It looks like either some stroke of luck will happen and someone will know how to create the pop up screen. Or I am stuck putting up multiple gallery/pages that hold roughly 30 photos, which I could do b/c it is probably better than the crazy way I have it set up now.
I just wish there was SOME WAY to keep my gallery the way it is or to have more pixels per page. I have been playing around with SmugMug which does all of the above. However, it is reinventing the wheel and I already love my gallery.
BTW on the one photo site, how did you get the arrows to pan to the next page? Also, did you create links for each photo to point to a page and when you are in your admin page do you have a ton of pages all down the side of your screen?
I have to go back and see if either of you have inserted directions. I am totally burnt out from work and I should probably re-read this tomorrow. Sorry if I still sound stressed..I am. If "smugmug" can do this, why can't I-Web? Sniff!!!! -
[945 Series] 945P Neo will not Post
Hi all! I have a 945 Neo Board with an Intel Pentium D processor. I also have 2 GB of RAM, a PCI-E RadeonX700 vid card, a SATA HD, and DVD burner. It is in an Antec case w/ 350 W power supply. I have a ps2 kb and mouse. I put it all together last night and the Black screen begins to boot. It detects the processor, the full amount of RAM, and the DVD burner and HD. Then I get a series of continuous beeps and a message that "keyboard cannot be detected" The BIOS then sits there asking to press DEL to enter into it. Obviously I cant because it does not detect the KB. I tried removing one stick of ram, and then I tried removing everything from the board except the vid card, kb and mouse. This is all to no avail.
As far as the power supply it only had the four prong connector instead of the eight that is on the board. I did plug the four prongs into the eight prong connector. Could this be the issue? Is the adapter necessary? Or is it a different issue? Any help would be appreciated because I am going nuts!!Well I have only tried to post this new mobo. ( Just to look around the BIOS)
I am still whiting to get my New PSU and HS&F.
I think my problem is similar to yours. Right now I'm using a P.O.S. PSU w/ a 20pin to 24pin adapter & only one P4 plug.
The mobo comes on for a few seconds then powers down. (Probably because of this POS PSU)
Once I get the new parts in the mail I think I will be fine.
There is a little more info on my New system in the tread
https://forum-en.msi.com/index.php?topic=92545.0 -
Delivery and Shipments for idocs posting
Hi
- warehouse shipment advice (EDI 945) related (to update qties, packing info, and post G/I)
can i use DELVRY01 or DELVRY02. . which one for what.
- customer ASN (EDI 856) related - SHPMNT01 to SHPMNT03
will it update delivery
& also the shipment documentHi there,
as its quite a bit of work to find out which fields to fill when posting idocs, here is an example idoc that updates LE shipments and does a shipment completion:
Message Type SHPMNT Basic Type: SHPMNT05
Segment Field Description Sample
E1EDT20 TKNUM Shipment Number 1101933359
E1EDT20 EXTI1 Shipment External reference 1101933359
E1EDT18 QUALF Qualifier CHA3%
E1EDT18 PARAM 3% (Means that all fields that are filled in the idoc shall be changed. others unchanged.
E1EDT10 QUALF To indicate that the sap must do a shipment completion 004
Repeat segment if you need to do other things
E1EDT10 IEDD Shipment completion end date 20110926
E1EDT10 IEDZ Shipment completion end time 101344
E1EDT20 VBELN Delivery number (with leading zeroes 10 digits) 0083127938
E1EDL24 POSNR Item Number (with leading zeroes 6 digits) 000001
E1EDL24 MATNR Material Number (with leading zeroes 18 digits) 000000000000450931
E1EDL24 WERKS Plant 74A7
E1EDL24 LGORT Storage location POLC
E1EDL24 CHARG Batch number LOLO -
Total Net Value is picking automatically into one G/l a/c in posting time
Hi to all,
i have one critical issuse ,
here i am doing new pricing procedure in that i put 4 condition types
80 ZLLU Actual user price ERL
850 Sub Total 80 849
860 ZTCS Tax collection 850 ZTS
872 ZOT1 Other charges 1 ZPK
880 Grand Total 850 879
946 ZGPS Price+ Tax + other 880 ZTS
955 Total 945 954
PR00 ERL
ZTCS ZTS
ZOT1 ZPK
ZGPS ERL for this 4 account keys i have assigned different G/L A/C's but while posting into account's. Total net value of billing is hitting into one G/l A/c (that is ERL). it is not hitting into different G/l A/c's
how it is possible can any clear by issuse ASAP
REgards
MuraliHi,
Check Price procedure which key's assign to each condition.
Check/Carry out configuration in t-code VKOA.
ELSE,
Go to VF02, put invoice number
Environment >>> Account determination analysis >>> Revenue account,
Here u will get detailed analysis, which condition is hitting proper G/L.
Kapil -
Update intel 945 graphics drivrs in xp?
hi,
i have the latest mac mini, and it has 945 intel graphics.
i want to know if i can DL and use the newest driver from intel, or will that botch my mini?
obviously, i only want to use the driver on the xp side, but i think it also has video bios enhancements and so on and i did some surfing and saw some posts that made it sound like this wasn't wise.
does anyone know if i can do this or not? the driver i want to use is here:
http://downloadcenter.intel.com/filter_results.aspx?strTypes=all&ProductID=2102& OSFullName=Windows*XPProfessional&lang=eng&strOSs=44&submit=Go%21
i assume i want the first one, not the embedded one.
anyone have any exp with this? my current driver seems to be: 6.14.10.4833 (may 25 '07)Hello mrsinatra,
So why did you buy mac mini since you want to use it with Windows XP?! You should better buy Dell mini pc or whatever (maybe AOpen mini pc). Mac mini is a MAC MINI, and its power is on MacOS do not forget this
Now seriously,
Using BootCamp you can install XP and then on your MacOS DVD you have all necessary drivers for your mac mini. You can of course download the latest drivers from Intel. However I think they are the same as the ones provided on your MacOS DVD. Personally I would not experiment with suspicious drivers, even if they are pretend to be the ones made by the manufacturer. Mac mini has one advantage over all other computers : its hardware is carefully selected to run with maximum power and robustness, so its better to trust on Apple provisioning rather than someone else.
Best regards.
Message was edited by: Getcho -
Migration Monitor error during Het. Sys Copy
We are doing an Het. Sys Copy from Aix-Orcle to Win IA64-Oracle using the standard indipendent procedure (export-import), on an Abap only instance.
During the import we got errors for the wrong migration key, despite it seemed well generated and we applied at the end the note 970518 point "D019527, 09/MAY/06".
Anyway after a bit the import process stopped due this error and we do not how what's went wrong:
" Execution of the command "C:\j2sdk1.4.2_04\bin\java.exe -classpath
migmon.jar -showversion com.sap.inst.migmon.imp.ImportMonitor -dbType
ORA -importDirs E:\Iveco_export\TS1\ABAP -installDir "C:\Program
Files\sapinst_instdir\NW04S\LM\COPY\ORA\SYSTEM\CENTRAL\AS-ABAP" -
orderBy "" -r3loadExe E:\usr\sap\TS1\SYS\exe\uc\NTIA64\R3load.exe -
tskFiles yes -extFiles yes -migrationKey 1G5fdEM50T1IrBzjt6TE5Pae -
dbCodepage 4103 -jobNum 3 -monitorTimeout 30 -loadArgs " -
stop_on_error" -trace all -sapinst" finished with return code 128.
Output: java version "1.4.2_04"Java(TM) 2 Runtime Environment, Standard
Edition (build 1.4.2_04-b05)Java HotSpot(TM) 64-Bit Server VM (build
1.4.2_04-b05, mixed mode)
ERROR 2007-06-21 08:33:44
CJS-30022 Program 'Migration Monitor' exits with error code 128. For
details see log file(s) import_monitor.java.log, import_monitor.log.
ERROR 2007-06-21 08:33:44
FCO-00011 The step runMigrationMonitor with step key
|NW_ABAP_OneHost|ind|ind|ind|ind|0|0|NW_Onehost_System|ind|ind|ind|ind|1|0|NW_CreateDBandLoad|ind|ind|ind|ind|10|0|NW_ABAP_Import_Dialog|ind|ind|ind|ind|5|0|NW_ABAP_Import|ind|ind|ind|ind|0|0|runMigrationMonitor was
executed with status ERROR .
byeIf you post logfiles, please put "code tags" around, this makes your logs readable.
If you read what you posted you will find:
> ERROR Import Monitor jobs: running 0, waiting 1, completed 17, failed 1, total 19. ERROR 2009-03-31 18:14:16 CJSlibModule::writeError_impl() CJS-30022 Program 'Migration Monitor' exits with error code 103. For details see log file(s) import_monitor.java.log, import_monitor.log.
Do that.
Markus -
Error: "Transaction not posted due to errors in price determination"
Hello,
Please tell me why this error occurs "Transaction not posted due to errors in price determination"
for purchasing document.
I have checked the PO and it contains all the valid pricing details.
Then why the error?
Thanks & Regards,
PriyankaHai
Check ur Pur.Grp and the Vendor U are using some time u may be using the differrnt vendor grp and pur grp or pur org thru which the pricing procedure hets triggered
thnk u
with rgds
moosa anis -
Inventory management: posting block : material master field
Hi,
In het material master you have a field Physical Inventory Blocking Indicator, but when I create a counting document (MI01) with posting block. The field in the material master is still blank. How can this happen?
Best regards,
Eric.Hi Eric,
I guess there is some inconsistency in your system,
Please refer to the SAP Note 355939 & 192571 and you might be able to fix the bug..
Note 355939
Summary
Symptom
This note is only of importance for you if you execute physical inventory functions using the R/3 System. The inconsistencies can usually be adequately eliminated using Note 192571. This note is only intended for customers who did not discover the inconsistency in the first period of the new fiscal year and who now have problems with the physical inventory indicators.
Additional key words
RMMMPERI, MMPV, physical inventory, PIINKON, MARD-KZILL, MARD-SPERR
Cause and prerequisites
See Note 192571.
Solution
To eliminate the inconsistencies, carry out the following steps in the corresponding sequence:
1. Implement the corrections from Note 192571
2. Also implement the attached correction instructions
3. Start program ZREPPI_FLAGS (from Note 192571)
4. Start program ZINVUT30 (from Note 67072)
Source code corrections
Note 192571
Summary
Symptom
Preliminary note:
This note only applies to you if you execute physical inventory functions in the R/3 System.
In the log of the period closing program running during the fiscal year change, the number of the records closed does not correspond to the actual number of records in the corresponding stock table on the database.
As a result, the physical inventory indicators were not moved from the current fiscal year to the previous year in the records that are not closed. This means that materials, for which a physical inventory was carried out in the previous year, are dealt with by the system as if a physical inventory has already been carried out in the current year.
This problem can affect materials created before the upgrade to Release 4.5.
Additional key words
RMMMPERI, MMPV, inventory, PIINKON, MARD-KZILL, MARD-SPERR
Cause and prerequisites
The problem is caused by a program error.
Solution
If you have not yet carried out the fiscal year change (for example, if you have a fiscal year variant with non-calendar fiscal year), the attached correction can correct the error.
If you do not yet use Release 4.5B with at least Hot Package 09, in the four following form routines you must implement the deletion/insertion sequence listed in the attachment only once. Do not implement them twice each time as described in the "Corrections" section.
- Form MARD_UPDATE_JW_DB2DB4
- Form MCHB_UPDATE_JW_DB2DB4
- Form MSKA_UPDATE_JW_DB2DB4
- Form MSKU_UPDATE_JW_DB2DB4
Caution: Implement the corrections WITHOUT comment lines or added comments !!!
Comments between EXEC SQL and ENDEXEC can lead to the 'DBIF_DSQL2_SQL_ERROR' at the fiscal year change.
If you carried out the fiscal year change in Release 4.5 or 4.6A and use R/3 Physical Inventory Management, you can, after implementing the attached correction in your system, repair the affected records as follows:
Run correction report ZREPPI_FLAGS.
After the execution of report ZREPPI_FLAGS, you should implement report ZINVUT30 mentioned in Note 67072 in your system and execute the report for those materials for which a physical inventory has already been executed in the current fiscal year.
If you recognize the inconsistency only in a later period, also refer to Note 355939.
Trust this helps
Regards
Merwyn -
ik heb gisteren het programma zoomit geïnstalleerd (vergrootglas). Ondertussen heb ik alles zo goed mogelijk weer verwijderd maar volgens mij heb ik het originele firefox-startscherm niet meer
waar vroeger Google stond staat nu Google default. Ik heb met het knipprogramma van windows een kopie van mijn startscherm gemaakt.You can't attach a screenshot to the first post that starts a thread, but you can do that in subsequent replies.
You can use the SearchReset extension to reset some preferences to the default values.
*https://addons.mozilla.org/firefox/addon/searchreset/
Note that the SearchReset extension only runs once and then uninstalls automatically, so it won't show on the "Firefox > Add-ons" page (about:addons).
If you do not keep changes after a restart or otherwise have problems with preferences, see:
*http://kb.mozillazine.org/Preferences_not_saved -
EDI 940 inbound,requisition, outbound 945 ship notice
I need to post EDI inbound warehouse shipping orders (i.e. requisitions) from a customer whose stock we maintain in our warehouse. I also want to respond with a
945 Warehouse Shipping Advice in response to actual shipment, follow-up to a status request and requisition cancellation request.
What standard functions, if any, can be used to run such a process and what IDocs should be used to support it?
Any help to get onto the right track with this project would be most appreciated.
Thank you.Hi Karuna,
I would like to know what is required to be configured in SAP for a reverse scenario than what was discussed in the thread.
i.e.
I want to sent a 940 to the Warehouse and receive a 945. Can you say what needs to be configured in SAP.
Thanks,
Raj -
Ik word steeds afgemeld in het came center, zeer frusterend. Hoe blijf ik online?
That's a good thought that could explain some cases, but not mine: these people definitely don't know my email address, and I'm not in their Address Book. (Some of these are people I might meet on a hike, say, and nod to in passing on other hikes once a or twice a year, and that's the extent of the "relationship"--no contact info ever exchanged. We don't even know what cities each other are from.)
we don't even know each others' email addresses, and even if we did, my Apple ID email is not one I use for actual emailing purposes. Nor do we know each others' phone numbers, nor gaming nicknames; often not even last names.
I should correct my first post: I said I "do now know well"... that should be "do NOT know well". -
Het GEAR-stuurprogramma kan momenteel niet worden geïnstalleerd.
Wie kan mij helpen met het oplossen van dit probleem?
Ik krijg na het downloaden van i-Tunes (alle versies), de volgende melding: Het GEAR-stuurprogramma kan momenteel niet worden geïnstalleerd. Het gebruik van de GEARAspiWD-voorziening door het GEAR-stuurprogramma wordt verwijderd als het systeem opnieuw wordt opgestart. Start het systeem opnieuw op en voer iTunes opnieuw uit.
Als ik dan opnieuw opstart en iTunes opnieuw wil installeren krijg ik opnieuw dezelfde melding.
Alvast bedankt voor de reacties!Fingers crossed, this post from the GEARsoft forums may be of assistance. (Unfortunately, it's in English.)
http://www.gearsoftware.com/support/forum/viewtopic.php?p=3452 -
K9AG Neo2-Digital Dead? Not Posting but all powered up
Hmm.
have just plugged back in my machine after decorating my flat, Vista fired up and went to desktop, I went in the kitchen to grab a drink, came back, and the monitor is on powersaving mode as if it blanked out for the screensaver. Wiggled the mouse, nothing. Hit some keys, nothing. Pressed the power button, nothing. Held the power button down for an eternity - didnt even shut down. No HDD activity, but all fans whirring away and seemingly 'on'.
Spec:
600W OCZ PSU
XFX 260GTX GFX
4x 1GB 633mhz DDR2
Phenom II 945 x 4 CPU
Vista 32 Bit
Now, the only way to shut down my pc was to turn the power off from the PSU. I switched back on. No post screen, nothing on the display. Sat in sleep mode. However, all fans on, DVD-R light gives a flash, HDD spins up, but no HDD light, nothing. Again, only way to turn off was to turn the PSU off.
So I go about taking the components out, cleaning, reseating, even took the CPU out and replaced with my original Athlon x 2. Still nothing.
Anyway, I'm at a loss. Im guessing the motherboard must be fried? Is there anything I can do without having to take it to a specialist to charge me the same money as a new mobo will cost me?Is your CPU the 95W or 125W version?
I suspect that CPU VRM MOSFET(s) may be fried. None of the 125W AM2/AM2+ were supported and then along comes AM3 and they show support for those 125W CPU's. Doesn't make a bit of sense to me, I've seen it on other similar MB's also. Look at the MOSFET's to the left of the CPU and see if any look overheated or burned.
This is a different MB but is an example of what to look for:
Maybe you are looking for
-
How many times can I re-install CS6?
How many times can I re-install CS6?
-
Xcode snapshots not working?
My snapshots are not restoring even though they say they are. My code is not changing and all the errors are still there. I'm panicking because this app may be a goner if I can't undo some of the things I did.
-
Mifi 4510l and Windows Live Mail
I recently purchased the 4510l to use while I was on the road. On the first trip I had excellent connection/speed and signal throughout. My biggest problem is when accessing some of my mail servers (mainly Mediacom) I get error 0x800ccc0e on all acco
-
Unlock code to Photoshop album Starter Edition 3
I need an unlock code so I can view my photos
-
API to Apply Credit Memo to a Deposit
We have a requirement to apply the Credit Memo to an outstanding Deposit in Oracle Financials through a program. Can someone provide me 1. An API to Create a Credit Memo 2. An API to apply the Credit Memo to a Deposit Thanks Vasu