How to address digital input & output, analogue input & output when communicate with mitsubishi fx1n plc

dear all,
i am new to labview, how to code or address digital input & output, analogue input & output when communicate with mitsubishi fx1n plc or crouzet plc.
pls help.
HM

http://search.mywebsearch.com/mywebsearch/redirect.jhtml?searchfor=mitsubishi+fx1n&cb=ZO&p2=%5EZO%5E...
Try the above link. I know it is a screen-full, but is a search result for Matrikon. They have a whole slew of OPC servers/clients you can try out. Personally, I would go with their OPC server for the Mitsubishi, and use Labview Datasockets. That would be the simplest with the lowest learning curve.
Otherwise, if you wish to use Modbus, you would have to get the commands/syntax from Mitsubishi; might be in their user manual, but I wouldn't lay bets on it. With the Matrikon stuff, the syntax is all built in.
Good luck which ever way you decide to go.
Dave

Similar Messages

  • How do you turn off the auto select behavior when working with shape layers?

    How do you turn off the auto select behavior when working with shape layers?
    I am using either of the path selection tools to select only some of the paths on the layer. I have the proper layer targeted. I have the selection too auto select option turned off.
    If another layer has a path in that area, that layer becomes auto targeted and I get the wrong path. Turning off the layer is the only way to avoid this but then I have to  turn on the layer back on between making my selection and transforming to use the other layer as guide. Is there any way to stop this auto select? Locking the other layer does not stop the auto select, just prevents editing.

    As far as i know the move tool options don't have any effect on the path selection tools.
    You might try clicking on one of the path points or on the path itself with one of path selection tools and if you want to select multiple points
    you can shift click with the Direct Selection Tool or Alt click to select the entire path.
    more path shortcuts:
    http://help.adobe.com/en_US/photoshop/cs/using/WSDA7A5830-33A2-4fde-AD86-AD9873DF9FB7a.htm l
    http://help.adobe.com/en_US/photoshop/cs/using/WSfd1234e1c4b69f30ea53e41001031ab64-7391a.h tml

  • How to force digital input sample rate?

    Does anyone know how to force a Digital Input sample rate and/or tell Core Audio which conversion clock to use... internal or external? Apparently both things can be done from Pro Tools, but I don't have it.  My problem is locking onto an A/D converter's 48K Toslink output.  I can set 48K in 'Audio - Midi' setup and the audio is perfect, but a few seconds later  Core Audio returns to the default 44.1K.  I need to force it to stay at 48K, or clock on the signal rather than internal clock.

    Braver,
    Let me clarify a few things. First, the 6733 supports correlated digital I/O. This means that the digital operation does not have its own clock. You can correlate the digital operation with the AO clock, which will allow a digital operation up to the max AO rate. You can generate a pulse train with an onboard counter and use that as your digital clock source. Also, you can use a completely external clock source to achieve the max digital rate of 10MHz. The knowledge base, linked below, points you to a couple of examples that ship with LabVIEW. Be sure and read the documentation associated with each example.
    Knowlege Base
    As for
    the example CDI Single Point clocked by Counter (E).vi, notice how the output of...

  • How to give digital inputs to ni 6501

    I am trying to give a digital data to a port of ni 6501... Can some one exlain in which format this datas shuld be given in a C++ code 

    Hi,
    You just need to change the XSD of your process.
    Someone posted something similar last week : How to change the input and output schema in BPEL process
    Hope it will help you ..
    romain.

  • 1820M digital inputs don't work with cable box, receiver digital outputs?

    I just installed an 1820M on an XP-Pro machine (AMD 3800+ X2). Downloaded the optical and coax loopback tests and they work fine. But I can't get it to take digital input from either my Comcast HD-DVR or my Denon AVR-1907 receiver. I know the Comcast DVR digital outputs work - they worked with my receiver and with my old Logitech 5300s.
    I've tried everything I can think of:
    - take external sync from S/PDIF
    - set the optical to ADAT so it doesn't mess up the coax s/pdif input
    This seems like such an obvious application. Has anyone gotten it to work?
    Thanks

    This is my point - the currently active channel does not produce sound through its multiple outputs unless Logic is playing.
    So, for example, if I am auditioning different drum grooves from RMX through the multiple outputs (for the purpose of putting effects/processors on the outputs in Logic) this only works when Logic is playing.
    Or if, in BFD, I have the direct Snare coming out of one output into an aux, and then a direct Kick coming out and output into another aux, I cannot hear them unless Logic is playing - I can only hear the ambient mic's as these are mapped to Outputs 1-2 which are the initial track you set the multiple output AU up on.
    If none of this is something you tend to do, I guess it's hard to understand!
    Thanks,
    Alex.

  • How can i show input text when no row present in database.

    Hi All,
    I am using Jdeveloper 11g Release1(11.1.1.4.0)
    I have created EO and VO which is based on that EO.
    By using Vo i have designed .jspx page ,on that page i have taken adf form which is based on that VO.
    My problem is when database table is blank (i.e zero row) then input text on page not displayed.
    I want to show blank input text when such condition occurs.
    Thanks
    Imran.

    Hi,
    You can set ExecuteWithParams as default activity in the task flow then method activity to return total no of rows passing to Router activity if your method has value 0 then call Create insert operation else do directly to page.
    Following idea could be your task flow
    Execute With param (default) > SetCurrentRowWithKey > GetTotalNoOfRows (VOImpl Method)
    |
    v
    Router
    1. If pageFlowScope outcome is 0 then call CreateInsert > MyPage
    2. if pageFlowScope outcome > 0 then MyPage
    hope it helps,
    Zeeshan

  • DAQmx: Digital - Continuous Output.vi example with PCI-6519 (error -200077)

    Bonjour everyone,
    Main goal :
    I want to use 1 digital output of the PCI-6519 harware to make  a staked light indicator blink when user is needed to operate the test station. 
    What I am trying:
    I open the labview 2013 wxample "DAQmx: Digital - Continuous Output.vi" to learn how I could use a DAQmx task to perform this blink instead of using a dynamic call of a VI changing the output in 'while loop'.
    The example states that my hardware should be able to run it but I always get an error -200077 right at the beginning with the DAQmx Timing.vi mentionning that my PORT2, line 0 does not support the 'Sample Clock' property which is hard coded in the example. I can't find a different property that this example will accept to try to change the status of my digital output on a time basis.  Does the PCI-6519 device support timing for a digital output or not?
    If anyone has a better or simplier idea to achieve such a simple goal, feel free to suggest.  I am using DAQmx for the first time and I don't know much about what my options are.
    Thanks 

    Hi Nienscecco,
    Unfortunately PCI-6519 doesn't support HW timing, I've just tried with a simulate PCI-6519 device and I confirm you that you must specify an external clock in order to use this example.
    Do you have some kind of frequency generator to provide it ? Or maybe another NI board with embedded counters in order to build it ?
    Thanks in advance for your answers.
    Mathieu_T
    Certified LabVIEW Developer
    Certified TestStand Developer
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    LabVIEW Tour
    Journées Techniques dans 10 villes en France, du 4 au 20 novembre 2014

  • How to use a GPIB card's LabView drivers to communicate with the card?

    I have an axiomtek AX4810P PCI-GPIB card and i have aquired LabView drivers from the manufacturer.
    This has put VI's for the GPIB functions on the 'user palette' but i can't work out how to use them to communicate with the card. can anyone help? please.

    LS,
    Thank you for contacting National Instruments.
    Unfortunately, since you are not using a National Instruments GPIB card, I do not have access to the drivers that were provided to you by your card's manufacturer. I would suggest contacting Axiomtek directly to obtain support using their drivers.
    However, I did write a small VI that demonstrates how to use similar National Instruments drivers with a National Instruments GPIB card. Keep in mind, this example VI is not intended to work with your particular card. The drivers you obtained from Axiomtek may have similar functions, however, and you can use my VI as a guide. My VI allows you to send a command to an instrument at address 2 on the GPIB card.
    Hope this helps!
    Matthew C
    Applications
    Engineer
    National Instruments
    Attachments:
    GPIB_Communication.vi ‏23 KB

  • How can I have each pass through a for loop communicate with a new indicator?

    Hello,
    I am using 16 color boxes to indicate how 16 channels are behaving.  If a color box is blue, its respective channel is running correctly, red means it has failed etc.  I am continuously checking each channel using a loop, and I wanted to update the channel colors every loop.  I have made an array of 16 numbers corresponding to the color I wish to have (which are blue = running, red = failed, green = completed, black = not in use).  However, I cannot find a way to pull these 16 numbers out of the array and to the color boxes short of 16 index arrays connected to the color boxes. 
    I understand how to convert each individual number to a color, I just don't know how to use a 16 times for loop to communicate with a different color box each pass through.  Is there any way to do this or should I just go for brute force?
    Thank you.
    Solved!
    Go to Solution.

    Sorry I keep making new posts.  Attached is an example i wrote up.  There are three cases in the disabled structure, each has a different implementation of what i belive your specs are.
    Tim Elsey
    LabVIEW 2010, 2012
    Certified LabVIEW Architect
    Attachments:
    update color box.vi ‏24 KB

  • Different family class used for input  and output when working with sockets

    I have seen more or less everywhere the following code to open a socket and to receive input and send output through it:
    Socket server = new Socket("anyservername", 25):
    OutputStream out = server.getOutputStream();
    PrintWriter pout = new PrintWriter (out, true);
    pout.println("Hello");
    InputStream in = server.getInputStream();
    BufferedReader bin = new BufferedReader (new InputStreamReader(in));
    String response = bin.readLine();
    What I do not understand is:
    Why the BufferedReader needs InputStreamReader as an argument whereas printwriter does not want the OutputStreamReader as an argument but it is OK with just the OutPutStream?
    I would tend to believe that they should be more or less at the same level and use the same arguments?.
    In that sense if I use BufferWriter instead of PrintWriter I bet It should be OK the following code?:
    OutputStream out = server.getOutputStream();
    BufferedWriter bout = new BufferedWriter (out);
    String myOut = bout.writeLine();
    Cheers
    Umbi
    Edited by: Imbu on Jun 2, 2008 2:40 PM

    1. Does it even compile?
    2. While there is a fair amount of symmetry between reader and writer classes, don't assume it's exhaustive. Your best friend is the API:
    [http://java.sun.com/javase/6/docs/api/]
    3. Those were just examples. Code it the way you feel is best. I would specify charsets to make sure the encodings were platform independent. Networking and all that, don't you know...

  • How to get default input values when using promt user for input

    I use "promt user for input" to input some values. The messageboard appears with blank boxes then I will input  new values. I want to make some default values in this blank boxes so that I needn't to enter new values. Is it possible ?

    Right click on he Express Vi terminal and choose open Front panel to convert it into a standard vi. Then open it. Enter a default value for each control, then right-click on the controls and go to data operation > make current value default.
    Message Edité par chilly charly le 11-18-2007 12:52 PM
    Chilly Charly    (aka CC)
             E-List Master - Kudos glutton - Press the yellow button on the left...        

  • How can I use the parallel port as an input channel to communicate with a SPECTROMETER?

    Hello,
    The sensing system we use is called: FieldSpec Pro from www.asdi.com.
    The spectrometer has a LPT terminal. I'd like to use LabVIEW to acquire signals from the spectrometer for further analysis.
    Thank you!

    Dennis,
    I appreciate your time.
    I have asked the copmany for such infos, but it seems to be confidential.
    Do I need an I/O DAQ-Card?
    Dennis Knutson wrote:
    About all that tells me is
    that I'm located in the same town as the manufacturer. You'll need to
    find some specification that describes the parallel port protocol.
    Without that, you're just wasting your time. Even if the instrument is
    constantly sending data, you'll need to know how to interpret the data
    and there's nothing that says it has to be sending constantly. Maybe
    you first have to write something to the port first. Talk to them and
    tell them you want to replace their software with software of your own
    and need to be able to read the data.

  • How to get the input values when create shpping cart(FPM_OIF_COMPONENT)?

    We want to remote other applications when create a new SC(neither ordered nor saved).
    We must transport the screen data which entired by users.
    Do you have a methord to get the screen value of SC in the FPM component FPM_OIF_COMPONENT?
    Thank you very much!
    I am looking forward to your reply!

    Solved,use the BADI BBP_DOC_CHANGE_BADI

  • How to make my input variable when labview is running ( URGENT)

    Hi I need help on labview.
    (1) I need to create a knob that increase the amplitude of a sine wave. I need to increase the amplitude of the sine wave while the program is running using the knob. I am only able to increase the amplitude of the sine wave when i stop the program, turn the knob to another amplitude and start running again. I cant increase the amplitude of the sine wave while running. Pls help me in this area.
    (2) I need also to create an array to store the amplitudes of the waveform that i need.The array must send in information One by one to the waveform generator at time intervals. Can someone help me in this area. Thanks

    Ah, the end of the semester, and school projects are due.  You won't find anyone on the list that will write you rprogram for you.  You would be better off posting the code you have so we can guide you to the solution better.
    1.  LabVIEW only reads a control value when you tell it to, so you'll either need a while loop and read the control over and over or use a while loop with an event structure which will read the control everytime you change it.
    2.  Use a while or for loop (while loop would be better, especially if your timing constant is large) and index the values use a delay or wait(ms) to add a delay before the next point.

  • How to Right Align the output of amount with currency?

    Hi,
    I have the following SQL query, which basically is the duplication of the SAP standard Item List.  The only difference is, the stock on hand is only for Warehouse 01.
    In the output, I manage to display eg: AUD 1321.00.  However, it is aligned to the center.  Is there a way that I can make it right align like the standard report?  Appreciate your help.
    SELECT T0.[ItemCode], T0.[ItemName], (select T100.OnHand from OITW T100 where T100.ItemCode=T0.ItemCode and T100.WhsCode='01') as 'InStock',T0.[CodeBars], T1.[ItmsGrpNam], T2.[FirmName], T0.[InvntryUom],
    ('AUD'+ replicate(' ',16-len(T0.[LstEvlPric])) + Convert (char(18),(cast ((round(T0.[LstEvlPric], 2)) as decimal(16,2))))  ) as 'Last Eval Price', (T0.[LastPurCur]+ replicate(' ',16-len(T0.[LastPurPrc])) + Convert (char(18),(cast ((round(T0.[LastPurPrc], 2)) as decimal(16,2))))  ) as 'Last Pur. Price',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=1 and T200.ItemCode=T0.ItemCode) as 'L 1',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=2 and T200.ItemCode=T0.ItemCode) as 'L 2',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=3 and T200.ItemCode=T0.ItemCode) as 'L 3',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=4 and T200.ItemCode=T0.ItemCode) as 'L 4',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=5 and T200.ItemCode=T0.ItemCode) as 'L 5',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=6 and T200.ItemCode=T0.ItemCode) as 'Price List 6',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=7 and T200.ItemCode=T0.ItemCode) as 'Price List 7',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=8 and T200.ItemCode=T0.ItemCode) as 'Price List 8',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=9 and T200.ItemCode=T0.ItemCode) as 'Price List 9',
    (SELECT T200.[Currency] + replicate(' ',16-len(T200.Price)) + Convert (char(18),(cast ((round(T200.[Price], 2)) as decimal(16,2)))) FROM ITM1 T200  INNER JOIN OPLN T201 ON T200.PriceList = T201.ListNum where T200.PriceList=10 and T200.ItemCode=T0.ItemCode) as 'Price List 10'
    FROM OITM T0  INNER JOIN OITB T1 ON T0.ItmsGrpCod = T1.ItmsGrpCod INNER JOIN OMRC T2 ON T0.FirmCode = T2.FirmCode

    Thanks. 
    But, does that mean the the right alignment in SAP Item list was done through UI? 
    Another question is:
    Normally, in an SAP query, when click Ctrl + left click the mouse at the bottom, I can see the total.
    However, with the query that I have created, it seems to cut off the first number.  Eg: The total should be AUD 231,123.00, but it is showing me AUD 31,123.
    Can you see how I can fix that?

Maybe you are looking for

  • Target is not coming in KKBC_PKO report

    Hi, In KKBC_PKO report showing actual cost for for the given period i.e 05. but the same time it is not showing the target cost. I have checked the COSP table for the target cost. It is also not there. In KKS5 report showing the target and Actual. Al

  • Displaying pagenumbers in table of contents in the 2nd page of a smartform.

    We have a requirement where we need to display "Table of contents" with headings and corresponding page numbers .The page numbers for the headings need to be picked up at run time.But the "Table of contents" is in the second page whereas the headings

  • Installation PB on Virtual PC

    Hi All, I'm Trying to Install A solaris 9 I386 on a Virtual PC. When boot using the Installation CD Setup loop on configuration Assistant and installation is not possible. When I'm using installation softaware CD1 I'm hanging after the interactive (o

  • Define a start page in reports

    hi, how can i define the start page and the total pages of a report(reports 6i) passing a parameter from Forms 6.0 to make this?? thanks

  • MacBook won't upgrade to Snow Leopard

    I have a Macbook 13" Late 2008 "Unibody" which I just downgraded from Mountain Lion to Leopard. That really upped the speed of the computer, which really was extremely slow on Mountain Lion. I then wanted to upgrade to Snow Leopard, for which I purch