Hi,
Try to use:
1.3.6.1.4.1.9.2.2.1.1.6 - InBitRate
1.3.6.1.4.1.9.2.2.1.1.8 - OutBitRate
1.3.6.1.4.1.9.2.2.1.1.28 - ifDescription

Similar Messages

  • How to check current PulseAudio sampling rate and other parameters?

    # pacmd list-sinks
    Daemon not responding.
    http://askubuntu.com/questions/299597/g … d-bit-rate

    lucke wrote:Did it mention having permission denied to /run/user/1000? If so, "chown bbarcher.users /run/user/1000" and perhaps "pkill pulseaudio; pulseaudio &".
    On pulse restart I get
    Unable to contact D-Bus session bus
    And a whole galore of errors.

  • OBIEE11g: How to check current environment installed/applied patches?

    Hi all,
    Does anyone know how to check current OBIEE environment installed/applied patches? I don't have the patch installs anymore and now trying to figure out how to view them. My current environment is OBIEE 11.1.1.5.
    Thank you in advance!

    To check Patches applied, do changes where ever required.
    Use this command
    cd $FMW_HOME/Oracle_BI1
    opatch lsinventory|grep applied
    In Windows from C:\OFM\Oracle_BI1\OPatch
    Use this command
    opatch lsinventory applied
    opatch.bat lsinventory –oh <EPM_ORACLE_HOME> –jdk <MIDDLEWARE_HOME>/jdk160_21
    To check the version login to Answers-> Administration you can find the version a top use weblogic user to see.
    Appreciate if you mark as correct/helpful

  • Ser. Int. 5 min Input/Output Rate

    Dear Net Pros,
    On my serial interface of my AS 5350, I am having the following output as given below. The 5 minute input rate is half of the 5 minute output rate. Can someone suggest how I can fix this problem. I am currently also having access-lists configured in my gateway. Need some solution at the earliest possible.
    Serial0/0 is up, line protocol is up
    Hardware is DSCC4 Serial
    Internet address is 61.11.227.114/30
    MTU 1500 bytes, BW 8192 Kbit, DLY 20000 usec,
    reliability 255/255, txload 11/255, rxload 5/255
    Encapsulation HDLC, loopback not set
    Keepalive set (10 sec)
    Last input 00:00:00, output 00:00:00, output hang never
    Last clearing of "show interface" counters 05:49:59
    Queueing strategy: fifo
    Output queue 0/4096, 8898 drops; input queue 0/4096, 0 drops
    5 minute input rate 162000 bits/sec, 240 packets/sec
    5 minute output rate 373000 bits/sec, 718 packets/sec
    6151942 packets input, 515269067 bytes, 0 no buffer
    Received 2447 broadcasts, 0 runts, 0 giants, 0 throttles
    39 input errors, 8 CRC, 31 frame, 0 overrun, 0 ignored, 0 abort
    17398133 packets output, 1121504239 bytes, 0 underruns
    0 output errors, 0 collisions, 0 interface resets
    0 output buffer failures, 0 output buffers swapped out
    0 carrier transitions
    DCD=up DSR=up DTR=up RTS=up CTS=up
    Rushabh

    Here is the Gateway Config for you:
    AS5350_1#sh run
    Building configuration...
    Current configuration : 11303 bytes
    ! Last configuration change at 01:30:05 UTC Mon Dec 15 2003
    ! NVRAM config last updated at 01:30:08 UTC Mon Dec 15 2003
    version 12.2
    service timestamps debug datetime msec
    service timestamps log datetime msec localtime
    service password-encryption
    hostname AS5350_1
    boot system flash c5350-is-mz.122-2.XB6.bin
    no boot startup-test
    logging buffered 30000 debugging
    aaa new-model
    aaa group server radius mind
    server 202.183.221.215 auth-port 1645 acct-port 1646
    server 61.11.231.122 auth-port 1645 acct-port 1646
    aaa authentication login default local
    aaa authentication login h323 group mind
    aaa authorization exec h323 group mind
    aaa accounting network h323 start-stop group mind
    aaa accounting connection h323 start-stop group mind
    aaa session-id common
    resource-pool disable
    spe country e1-default
    spe 1/00 2/09
    firmware location flash:np.8.8.1.spe
    ip subnet-zero
    ip cef
    no ip domain-lookup
    voice class codec 1
    codec preference 1 g723r63 bytes 48
    codec preference 2 g723ar63
    codec preference 3 g723ar53
    codec preference 4 g729r8
    mta receive maximum-recipients 0
    dial-control-mib retain-timer 1000
    dial-control-mib max-size 1200
    controller E1 3/0
    framing NO-CRC4
    ds0-group 1 timeslots 1-15,17-31 type r2-digital r2-compelled ani
    cas-custom 1
    country china
    category 2
    answer-signal group-b 1
    dnis-digits min 1 max 9
    groupa-callerid-end
    controller E1 3/1
    framing NO-CRC4
    ds0-group 1 timeslots 1-15,17-31 type r2-digital r2-compelled ani
    cas-custom 1
    country china
    category 2
    answer-signal group-b 1
    dnis-digits min 1 max 9
    groupa-callerid-end
    controller E1 3/2
    framing NO-CRC4
    ds0-group 1 timeslots 1-15,17-31 type r2-digital r2-compelled ani
    cas-custom 1
    country china
    category 2
    answer-signal group-b 1
    dnis-digits min 1 max 9
    groupa-callerid-end
    controller E1 3/3
    framing NO-CRC4
    ds0-group 1 timeslots 1-15,17-31 type r2-digital r2-compelled ani
    cas-custom 1
    country china
    category 2
    answer-signal group-b 1
    dnis-digits min 1 max 9
    groupa-callerid-end
    gw-accounting h323
    gw-accounting syslog
    gw-accounting h323 vsa
    gw-accounting voip
    translation-rule 1
    Rule 0 ^111856 0
    translation-rule 2
    Rule 0 ^112856 0
    translation-rule 3
    Rule 0 ^113856 0
    interface FastEthernet0/0
    ip address x.x.x.x 255.255.255.248
    ip access-group 101 in
    ip accounting output-packets
    ip route-cache flow
    duplex auto
    speed auto
    interface FastEthernet0/1
    no ip address
    shutdown
    duplex auto
    speed auto
    interface Serial0/0
    ip address x.x.x.x 255.255.255.252
    ip access-group 101 in
    ip accounting output-packets
    no cdp enable
    interface Serial0/1
    no ip address
    shutdown
    clockrate 2000000
    ip classless
    ip route 0.0.0.0 0.0.0.0 61.11.227.113
    ip http server
    logging 61.11.231.122
    access-list 101 permit ip 202.183.221.208 0.0.0.15 any
    access-list 101 permit ip 61.11.231.120 0.0.0.7 any
    access-list 101 permit ip host 64.50.72.85 any
    access-list 101 permit ip host 210.55.9.194 any
    access-list 101 permit ip host 64.50.72.123 any
    access-list 101 permit ip host 203.144.226.198 any
    access-list 101 permit ip host 66.15.38.214 any
    access-list 101 deny tcp any any
    access-list 101 deny udp any any
    access-list 101 deny ip any any
    snmp-server community CSCO14344 RW
    snmp-server trap-source FastEthernet0/0
    snmp-server packetsize 8192
    no snmp-server enable traps tty
    radius-server host 202.183.221.215 auth-port 1645 acct-port 1646 key 7 0822455D0
    A16081E1C0F
    radius-server host 61.11.231.122 auth-port 1645 acct-port 1646 key 7 094F471A1A0
    A1A1B0508
    radius-server retransmit 3
    radius-server authorization permit missing Service-Type
    radius-server vsa send accounting
    radius-server vsa send authentication
    call rsvp-sync
    call application voice debit tftp://61.11.231.122/app_debitcard.2.0.2.8.tcl
    call application voice debit uid-len 6
    call application voice debit pin-len 6
    call application voice debit language 1 en
    call application voice debit set-location en 0 tftp://61.11.231.122/prompts/en/
    voice-port 3/0:1
    echo-cancel coverage 24
    compand-type a-law
    cptone CN
    bearer-cap Speech
    voice-port 3/1:1
    echo-cancel coverage 24
    compand-type a-law
    cptone CN
    bearer-cap Speech
    voice-port 3/2:1
    echo-cancel coverage 24
    compand-type a-law
    cptone CN
    bearer-cap Speech
    voice-port 3/3:1
    echo-cancel coverage 24
    compand-type a-law
    cptone CN
    bearer-cap Speech
    mgcp profile default
    dial-peer cor custom
    dial-peer voice 1 pots
    preference 1
    destination-pattern 111856T
    translate-outgoing called 1
    direct-inward-dial
    port 3/0:1
    dial-peer voice 2 pots
    preference 2
    destination-pattern 111856T
    translate-outgoing called 1
    direct-inward-dial
    port 3/1:1
    dial-peer voice 3 pots
    preference 3
    destination-pattern 111856T
    translate-outgoing called 1
    direct-inward-dial
    port 3/2:1
    dial-peer voice 4 pots
    preference 4
    destination-pattern 111856T
    translate-outgoing called 1
    direct-inward-dial
    port 3/3:1
    dial-peer voice 5 pots
    preference 1
    destination-pattern 112856T
    translate-outgoing called 2
    direct-inward-dial
    port 3/0:1
    dial-peer voice 6 pots
    preference 2
    destination-pattern 112856T
    translate-outgoing called 2
    direct-inward-dial
    port 3/1:1
    dial-peer voice 7 pots
    preference 3
    destination-pattern 112856T
    translate-outgoing called 2
    direct-inward-dial
    port 3/2:1
    dial-peer voice 8 pots
    preference 4
    destination-pattern 112856T
    translate-outgoing called 2
    direct-inward-dial
    port 3/3:1
    dial-peer voice 9 pots
    preference 1
    destination-pattern 113856T
    translate-outgoing called 3
    direct-inward-dial
    port 3/0:1
    dial-peer voice 10 pots
    preference 2
    destination-pattern 113856T
    translate-outgoing called 3
    direct-inward-dial
    port 3/1:1
    dial-peer voice 11 pots
    preference 3
    destination-pattern 113856T
    translate-outgoing called 3
    direct-inward-dial
    port 3/2:1
    dial-peer voice 12 pots
    preference 4
    destination-pattern 113856T
    translate-outgoing called 3
    direct-inward-dial
    port 3/3:1
    dial-peer voice 5555 pots
    dial-peer voice 333 voip
    destination-pattern 111856T
    fax rate 14400
    fax protocol t38 ls-redundancy 0 hs-redundancy 0
    gateway
    line con 0
    line aux 0
    line vty 0 1
    exec-timeout 20 0
    password xxxx
    logging synchronous
    line vty 2 4
    exec-timeout 20 0
    password xxx
    line vty xxx
    exec-timeout 2 0
    password xxxxxx
    line 1/00 1/59
    no flush-at-activation
    modem InOut
    line 2/00 2/59
    no flush-at-activation
    modem InOut
    scheduler allocate 10000 400
    ntp clock-period 17179604
    ntp update-calendar
    ntp server 192.16.202.3
    ntp server 134.222.86.7 prefer
    end
    Rushabh

  • How to force digital input sample rate?

    Does anyone know how to force a Digital Input sample rate and/or tell Core Audio which conversion clock to use... internal or external? Apparently both things can be done from Pro Tools, but I don't have it.  My problem is locking onto an A/D converter's 48K Toslink output.  I can set 48K in 'Audio - Midi' setup and the audio is perfect, but a few seconds later  Core Audio returns to the default 44.1K.  I need to force it to stay at 48K, or clock on the signal rather than internal clock.

    Braver,
    Let me clarify a few things. First, the 6733 supports correlated digital I/O. This means that the digital operation does not have its own clock. You can correlate the digital operation with the AO clock, which will allow a digital operation up to the max AO rate. You can generate a pulse train with an onboard counter and use that as your digital clock source. Also, you can use a completely external clock source to achieve the max digital rate of 10MHz. The knowledge base, linked below, points you to a couple of examples that ship with LabVIEW. Be sure and read the documentation associated with each example.
    Knowlege Base
    As for
    the example CDI Single Point clocked by Counter (E).vi, notice how the output of...

  • How to bind complex input/output types in web service data control

    Hi,
    I have created data control using external web service for simple input & output data type and its working fine.
    But I don't know how it can be done for complex data types.
    My external Web services have complex input & output types. Such as java object which contains another java object again it contains another java object or arry or java collection etc.
    Each my service has one complex input data type and for this no user input is require so how I can do it without using any component for it.
    I want to bind my page components with this input & output type.
    What is the best approach to do this and how to bind screen component.
    Regards,
    Devang

    Hi,
    Thanks frank.
    I already check this link before posting this so if you have any other link then kindly reply.
    Regards,
    Devang

  • How to Immediately Change Counter Output Rate?

    I have a piece of code that largely works like this example: http://zone.ni.com/devzone/cda/epd/p/id/5493
    In other words, I set up the Counter Output with some initial frequency and duty cycle, but then during the main loop of my program I continuously change the frequency to a new value based on other criteria.
    I'm using an M-series PXI card and LabVIEW RT.
    The problem I'm having is that the card waits for the next edge before changing the counter output rate. For instance, lets say it is going at a low frequency and I am upping to a high frequency. If the command arrives in the middle of the current pulse, it will wait to complete the low-rate pulse before starting the high frequency output. Is there a way to make it interrupt the current count and immediately start counting at the new rate?
    Thanks,
    Isaac

    Hi Isaac,
    I posted the code in LV 8.2 so you should be able to open it now (it sometimes takes several minutes to upload).
    There are a few limitations to using the digital lines instead of the counters:
    1.  The digital lines are updated off of a sample clock which will be much slower than a timebase.  For example, on the 6221 the maximum update rate is 1 MHz, while the counter output has a max timebase of 80 MHz. As a result, the number of frequencies you can generate are going to be more restricted (divide down from 1 MHz vs. 80 MHz).
    2.  On M series devices, the digital lines must be clocked from an external source.  This could be generated from a counter
    3.  You have to build the digital waveform, which is a bit tricky (I think the example code should help out with that but I haven't had time to thoroughly test it).
    4.  If you are generating digital lines at fast rates, you will need to write quite a few samples at a time to the output buffer to ensure the data does not underflow.  If the buffer includes multiple periods of the digital signal, you would have the case that using the counter output would still update more immediately.
    Again, to determine the best course of action it would be useful to know what frequencies you want to generate and which exact hardware you are using. I just mentioned the digital lines as an alternative to the counters, but it might not be ideal for your situation.
    -John
    John Passiak

  • How to address digital input & output, analogue input & output when communicate with mitsubishi fx1n plc

    dear all,
    i am new to labview, how to code or address digital input & output, analogue input & output when communicate with mitsubishi fx1n plc or crouzet plc.
    pls help.
    HM

    http://search.mywebsearch.com/mywebsearch/redirect.jhtml?searchfor=mitsubishi+fx1n&cb=ZO&p2=%5EZO%5E...
    Try the above link. I know it is a screen-full, but is a search result for Matrikon. They have a whole slew of OPC servers/clients you can try out. Personally, I would go with their OPC server for the Mitsubishi, and use Labview Datasockets. That would be the simplest with the lowest learning curve.
    Otherwise, if you wish to use Modbus, you would have to get the commands/syntax from Mitsubishi; might be in their user manual, but I wouldn't lay bets on it. With the Matrikon stuff, the syntax is all built in.
    Good luck which ever way you decide to go.
    Dave

  • How to check users inputs

    hi,there
    i am developing an on-line shop,at the end of checking out process , the users are supposed to submit a details form which including first name ,surname, address,email, phone no, card number etc. Can any one tell me how to check those details are valid before sending to database by using javabean or taglib.
    any information is helpful , thanks in advance.

    You have three choices:
    (1) Client-side checking using JavaScript,
    (2) Server-side checking using JavaBeans,
    (3) Both.
    You can check on the client side using JavaScript to make sure that e-mail address formats are valid, numbers are numbers, strings are the right length and format, dates are correct for the locale, etc. You might want to look at the JSTL I18N capabilities here to make sure your pages can handle different locales. This saves you a network roundtrip if something is formatted incorrectly.
    The server-side checking is different: it makes sure that the input satisfies business rules. You can check for correct format again if you wish, OR assume that the client has already taken care of this. (Depends on how paranoid you want to be.) The business rules for correctness belong on the server side, not in the client.
    I'd recommend both. They really are two different kinds of checks.
    MOD

  • How to check date input.

    In a JText, I input a date valu, when i got the value ,i want to check if it's reasonable.
    but idon't know how to check a number:
    for example:
    i input 31/31/2004,
    you know it's not reasonable.
    how to check it?

    Here is a function that check for a valid date:
    public boolean validDate(String strDatum)
    boolean dane = true;
    Calendar calendarDatum = Calendar.getInstance();
    int godina = 0, mesec = 0, den = 0, najgolemDen = 0;
    int i;
    if(strDatum.length()<10)
    dane = false;
    else
    for(i=0;i<2;i++)
    if(!Character.isDigit(strDatum.charAt(i)))
    dane = false;
    for(i=3;i<5;i++)
    if(!Character.isDigit(strDatum.charAt(i)))
    dane = false;
    for(i=6;i<10;i++)
    if(!Character.isDigit(strDatum.charAt(i)))
    dane = false;
    if(dane)
    godina = Integer.parseInt(strDatum.substring(6,10));
    mesec = Integer.parseInt(strDatum.substring(3,5));
    den = Integer.parseInt(strDatum.substring(0,2));
    if(mesec>12||mesec<1)
    dane = false;
    else
    calendarDatum.set(godina,mesec-1,1);
    najgolemDen = calendarDatum.getActualMaximum(Calendar.DAY_OF_MONTH);
    if(den>najgolemDen)
    dane = false;
    }//if(dane)
    }//else (ako dolzinata e 10)
    return dane;
    }

  • Help,how to check a input type?

    Dear all experts,
    in the selection-screen,user need to key in the vendor consignment code ( vdrcsg  for mslb-lifnr ) some user key in storage location ( mseg-lgort ) in this field. Is there anyway tat i can do verification before procees to the start-of-selection? how to check if the user key in correct data type to the selection screen? thanks

    hi Joan,
            Check these links :
    http://help.sap.com/saphelp_erp2005vp/helpdata/en/79/34a234d9b511d1950e0000e8353423/frameset.htm
    http://www.erpgenie.com/abap/selection_screens.htm
    http://www.sapdevelopment.co.uk/reporting/selscr/selscr_loopscreen.htm
    priyanka.

  • [SOLVED] how to check current colorscheme in vimrc?

    I am trying to write a function in vimrc that behaves differently based on colorscheme but I can't work out how to test the value of :colorscheme in vimrc. I'm trying to do this:
    if (&colorscheme == 'myscheme')
    ...something...
    else
    ...something else...
    endif
    But colorscheme is isn't a variable so the usual way of checking &variable doesn't work. Thanks for heping...
    Last edited by starfry (2013-01-19 20:12:21)

    Thank you Vain, that is the answer I was looking for. "color[scheme]"  does indeed output the name of the current color scheme but I cound not get it to work in the conditional. Using the g:colors_name variable works a treat. Very much appreciated

  • How many number of input/output arguments allowed in Stored procedure

    Please let me know how may input and output arguments are allowed in Oracle stored procedure.
    I wan't to writer one generic SP and for that I need to know the limitation on the number of arguments. I am using Oracle 8.0.5.

    The output from the BPEL process will be in XML format.
    Your requirement is not clear, please state it properly what are you trying to do.
    -Yatan

  • How to check current package/software versions?

    How do I check the current versions of packages or software? For example which version of apache or svn I have installed.
    Thanks.
    -z

    Most software that's installed via Apple's installer stores a receipt in /Library/Receipts
    You can look at the /Contents/version.plist file within the .pkg to see the version number associated with the package.
    This doesn't always cut it, though - for example Apache (as well as several other server components) may get updated as part of a security update so you won't see an 'apache.pkg' in /Library/Receipts
    In this case, though, it's probably easier to ask Apache directly...
    $ httpd -v
    Server version: Apache/2.2.13 (Unix)
    Server built: Oct 16 2009 02:12:22
    Most services support some kind of command-line switch (typically -v or -V) that gives you version information.

  • How to check current Autoconfig version

    How can we check Autoconfig current version/Rollup level

    What patch should i apply to make the Autoconfig as latest?
    The latest AutoConfig patch is "Patch 5985992 - TXK AUTOCONFIG ROLLUP PATCH Q (JUL/AUG 2007)" which is also included in "Patch 5903765 - Applications Technology 11i.ATG_PF.H.delta.6"
    Is autonfig patch cumulative ?Yes.

Maybe you are looking for