How to Define Limit to Numeric Control

Dear all,
I am controlling a motor which is pressing to load cell. I am controlling the motor position with a numeric controller in the front panel, the question is when i  accidently enter a large value(undesired motor's new motor position), than it could damage the load cell.
In this case : Can we arrange a numeric control in the front panel so that it can accept numbers only between "0" and "10".
Also : Is it also possible to arrange this from block diagram with wiring reference element as maksimum limit to the numeric control ?
Kind Regards,
Best Wishes.

Right click on your numerical control, go to properties, click the 'Data Entry' tab. Un-tick 'Use Default Limits'.
You can now set Minimum, maximum, Increment etc.
This can be done with a property node too if you want to change the values programatically.
Attachments:
dataentry.png ‏41 KB

Similar Messages

  • How to stop text labels on numeric controls from disappeari​ng

    Got a nuisance problem I'd like to correct.  When I've got a previously defined numeric control (such as a slide or knob) with text labels, upon entering the control properties window and selecting the "text labels" tab, the first label defaults to clear/empty.  This is a nuisance because the text has to be retyped every time when modifying the text labels.  Is this a bug or a feature?  Is there any way to turn it off?  Thanks.

    "I've always wanted to be the first to discover a bug in a new LV release! "
    Thank you for sharing that with us. You are helping to make LV even beeter than it is.
    regarding your quote "I've always wanted to be the first to discover a bug in a new LV release! "
    Please see the LabVIEW Champions Blog titled "The Leaders Lead" that can be found here.
    http://forums.lavag.org/blog/champions/index.php?
    How is your nose?
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • How to create a numeric control (of any type) that can ONLY be increased or decreased by one 'unit' at a time?

    As in the title.  I wish to create a numeric control (no current limitations on its type) with a range of 1-10 (and a step of 1).  The only difficulty I'm having is that the user must only be able to increase or decrease it by 1 at any time.  The code initiated by this value change must have completed at least once before the value can be changed again.  This is because the VI's code is mostly contained in a while loop, and the control is read once every iteration and its last value must not differ by more than 1.
    Is this possible with LabVIEW 6.1 and if so, how?
    One of the solutions I've come up with so far is to disable the control immediately after it's read, and to enable it again immediately before it's read for the next time (I have to assume that the user is unable to click twice before the control is disabled).  Is this an acceptable method or is there a better way?
    I also had an idea of partially disabling a normal numeric control such that it could not be typed in - only the arrows remained operational.  However, i don't know quite how to do this.
    James
    Never say "Oops." Always say "Ah, interesting!"
    Solved!
    Go to Solution.

    Yes, i realize my solution needs the idea that followed it to be feasable in order to work properly.  My bad!
    I did wonder about using a combination like that, but I hoped it could all be done with one object.  Ah well - just means adding an extra little bit of code.  No probs.
    Thank you anyway.
    Never say "Oops." Always say "Ah, interesting!"

  • How can I limit numeric codes in a text field?

    How can I limit numeric codes in a text field? For example I want to list Industry SIC codes and I want to block someone from inputting an exlcuded industry code.

    We don't offer that type of input restriction for a text field. 
    Can you create a list of all allowed codes and use a Drop Down menu or Single/multiple Choice field? 
    Thanks,
    Josh

  • How to get y axis value(in a numeric control) by providing x-axis value using wave graph

    Hi,
    I'm new here, Sorry if i have selected wrong Location.
    I want to get Y-axis value (in a numeric Control) by providing X-axis Value using Wave graph.
    i want to do calculations with the obtained value.
    i have attached File and Snapshot.

    Well, you are using the Dynamic Data Type, which I almost never use, but if you convert the data to a WaveForm (using From DDT on the Signal Manipulation Palette, which is a choice when you right-click on the DDT Wire), you should be able to do this.  Do you know about how Waveforms are stored?  They are a Cluster, with t0 being a TimeStamp for the start of the Waveform, dt being the time step, and Y being the samples.  So if you want a point at 0.5 seconds and dt is 0.001, you would pull out the point at Index 499 (offset 0) from the Y array.
    Bob Schor

  • How to change numeric control and indicator radix programmat​ically?

    Hi All,
     I need to know how can we change the radix of numeric control as well as numeric indicator while program is running.
    Regards,
    Pramod M G
    Solved!
    Go to Solution.

    Right.  Sorry   Display Format -> Format
    Jim
    You're entirely bonkers. But I'll tell you a secret. All the best people are. ~ Alice

  • Dynamically set the upper limit of a numerical control

    I want to dynamically setting the upper limit of a numerical control. The maximal value that is allowed to input is calculated by the code, so that if the value input by the user exceeds the upperlimit,  a warning comes out and the input value is automaticaly reset to zero.
    I wired the calculated upper-limit to the property node of the numerical control using ''Data Range > Maximum" property, but it does not work as I expected.
    Anyone has suggestion on this? Thanks a lot.

    Can you attach your code?
    Dejun wrote:
    ... but it does not work as I expected.
    I cannot read your mind. What do you expect? What to you see instead?
    Overall, you are in a catch22 scenario if I understand you right. If you set the max of the control to coerce to a certain value and you enter a larger value, it will be coerced to the upper limit and the code does not see the original out-of-range value and you cannot successfully test it with a comparison operation. Maybe you can set it to "ignore" instead of "coerce" or not even set an upper limit. Simply use "in range and coerce" and reset the value under the desired conditions (e.g. via  a local variable) before handing it to the rest of the code. You could even wrap this into an xcontrol.
    LabVIEW Champion . Do more with less code and in less time .

  • How to detect the key enter with a numerical control without using loop event?

    I want to accept a numerical value only when the key enter is pressed, but without using the event. How to detect the char "enter" with a numerical control?
    Thanks!

    When the user edits a numeric control with a keyboard, its property "key focus" is true. When the user hits enter, key focus becomes false. Poll the property to latch the control valuse at the true-false transition. That won't work if the user modify the control using up and down arrows.
    LabVIEW, C'est LabVIEW

  • How to concatenate string with a numeric control ?

    Hi,
    How to concatenate string with a numeric control ?
    Thankyou.
    Solved!
    Go to Solution.

    Its simpler to just use the Format Into String.
    Attachments:
    Format Into String.png ‏11 KB

  • How to modify input range (DAQ assistant) with a numeric control ?

    hello every one
    I am currently working with the NI USB-6218 acquisition card.
    I would like, in order to acquire a signal, to be able to choose the input range of the DAQ assistant with a numeric control ( and not by opening the DAQ assistant window ) (like the "number of sample" and the "rate" entry...)
    Is it possible and if yes, how ?
    Thanks so much in advance for your answers !
    Solved!
    Go to Solution.

    hello
    sorry I forgot it. but after spending a few hours on the problem this morning, i solved it Apparently, I corrupted the general DAQmx assistant last friday. By restarting my computer this morning, this issue was solved and I was able to transform the constant into command for the input range.
    Thanks a lot for your help !!!
    Guyua

  • How can I highlight the default data in a numeric control when a VI loads.

    I have a VI that features a string constant that asks for a numeric response via a numeric control, a "next" button that enters the data (controlled by the enter key), and two leds, one that lights if the data entered is correct, and one that lights if the data entered is incorrect.  Is there anyway that I can make sure that when this VI loads, the zero in the numeric control is highlighted?
    Currently the opeator must use the mouse to highlight the zero in the numeric control, type the number and press enter ("next") to advance in the program.  I want the operator to be able to simply type the number after the VI loads and press enter.  This would require the zero to be highlighted when the VI loads.
    Is there anyway that I can format the numeric control to do this?

    If you set the key focus of the control to true (Right click on
    control->Create->Property Node, then on the property node, select
    "Key Focus") before anything else, it should be highlighted when you
    run the program.

  • How to separate "Key down" event from panel and numerical control

    Hi, All
    I have a vi proecess key down events for panel and  a numerical control in this panel. the application will do: 
    1. when panel is focused, user can use "up" and "down" key to driver some hardware.
    2. when the numerical control has the focus, "up" and "down" key will change it's value as usual.
    somehow the second one did not work, because the panel "key down" event was trigger as well when I use "up' "down" key inise the numerical control. 
    then I used "Key down?" of numerical control to block the "up/down" key. But the first time when I run the Vi, the panel still got triggered one time. 
    any suggestions on this? test code attached  in this post too. 
    thanks
    CQ
    Solved!
    Go to Solution.
    Attachments:
    KeyDown_Up_valuechange.vi ‏16 KB

    This works for me in 2014.  In short, you just need to check to see if your numeric has the focus.  If it doesn't, then you process the key value.  No need for any other event here except for the stop button.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines
    Attachments:
    KeyDown_Up_valuechange_BD.png ‏32 KB

  • Numeric control error handling

    Hi all,
    I have two question about numeric control.
    1) "How to handle invalid inputs?"
    Let say, I have one numeric control that can only accept 0 to +inf (Range). So negative input will be invalid data input. Whenever I typed the negative value on it, this control automatically changed back to default (min) value. What I want is that. Is there anyway to detect invalid user input? So that I can program whenever user input negative number, it will automatically change back to previous valid input (not default value).
    2) "How to assign the dynamic range of numeric control?"
    I used property node to assign the range but my problem is that. I assigned min 0.1, max 1.2 and increment 0.1 but I cant able to select 1.2 or sometime 0.1 by using increment/decrement arrow. Maybe because of floating points? And also I want to do when user input overrange value (eg.1.3) by typing, the value should go back to previous valid input.
    Any idea? Thanks

    You can choose how LV will react on entries exceeding a limit. The default is, that LV coerces the value to the limit. But you can also ignore the limit and the user can enter any value.
    Nevertheless, if you ignore the limits, you always have to check in your software for invalid values!
    Regarding 2) i couldn't reproduce what you described. Maybe you should post a little example....
    For the 2nd part of your question, please see my answer above...
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • How to define the size of private folder in Easy DMS?

    Hi,
    I have to ristrict the user to keep  the data in private folder after the maximum limit
    please help me how to define the private folder size in easy DMS.
    after the limit user is not able to keep data in private folder.

    Hi,
    This can be done in SAP Customization / SPRO
    Pl. check :
    Cross-Application Components>Document Management>Control Data>Define Document types
    Here the size limit can be defined.
    Also check : http://scn.sap.com/community/plm/document-management/blog/2014/06/20/how-to-create-dir-and-document-type-in-dms
    Hope this helps
    Regards,
    Remi

  • How to populate data in table control  .

    hi all,
    i put matnr no. in screen no. 103
    validation is done at that screen only.
    now when i want to modify dat record
    when i put matnr no. at screen 103
    so how i will get all  data of dat number to table control screen.

    Hi Darshan,
       Here is a detailed description of how to update data in table controll.
      Updating data in table control
    The ABAP language provides two mechanisms for loading the table control with data from the internal table and then storing the altered rows of the table control back to the internal table.
    Method 1: Read the internal table into the Table Control in the screenu2019s flow logic.  Used when the names of the Table Control fields are based on fields of the internal table.
    Method 2: Read the internal table into the Table Control in the module pool code. Used when the names of the Table Control fields are based on fields of the database table.
    Method 1 (table control fields = itab fields)
    In the flow logic we can read an internal table using the LOOP statement. Define the reference to the relevant able control by specifying WITH CONTROL <ctrl>
    Determine which table entry is to be read by specifying CURSOR <ctrl>-CURRENT_LINE.
    After the read operation the field contents are placed in the header line of the internal table. If the fields in the table control have the same name as the internal they will be filled automatically. Otherwise we need to write a module to transfer the internal table fields to the screen fields.
    We must reflect any changes the user makes to the fields of the table control in the internal table otherwise they will not appear when the screen is redisplayed after PBO processing, (eg, after the user presses Enter or scrolls) However, this processing should be performed only if changes have actually been made to the screen fields of the table control (hence the use of the ON REQUEST)
    PROCESS BEFORE OUTPUT.
    LOOP AT ITAB_REG WITH CONTROL TCREG
    CURSOR TCREG-CURRENT_LINE.
    ENDLOOP.
    PROCESS AFTER INPUT.
    LOOP AT ITAB_REG.
    MODULE MODIFY_ITAB_REG.
    ENDLOOP.
    MODULE MODIFY_ITAB_REG INPUT.
    MODIFY ITAB_REG INDEX TCREG-CURRENT_LINE.
    ENDMODULE.
    Method 2 (table control fields = dict. fields)
    If using a LOOP statement without an internal table in the flow logic, we must read the data in a PBO module which is called each time the loop is processed.
    Since, in this case, the system cannot determine the number of internal table entries itself, we must use the EXIT FROM STEP-LOOP statement to ensure that no blank lines are displayed in the table control if there are no more corresponding entries in the internal table.
    PROCESS BEFORE OUTPUT.
    LOOP WITH CONTROL TCREG.
    MODULE READ_ITAB_REG.
    ENDLOOP.
    PROCESS AFTER INPUT.
    LOOP WITH CONTROL TCREG.
    CHAIN.
    FIELD: ITAB_REG-REG,
    ITAB_REG-DESC.
    MODULE MODIFY_ITAB_REG
    ON CHAIN-REQUEST.
    ENDCHAIN.
    ENDLOOP.
    MODULE READ_ITAB_REG OUTPUT.
    READ TABLE ITAB_REG INDEX TCREG-CURRENT_LINE.
    IF SY-SUBRC EQ 0.
    MOVE-CORRESPONDING ITAB_REREG TO TCREG.
    ELSE.
    EXIT FROM STEP-LOOP.
    ENDIF.
    ENDMODULE.
    MODULE MODIFY_ITAB_REG INPUT.
    MOVE-CORRESPONDING TCREG TO ITAB_REG.
    MODIFY ITAB_REG INDEX
    TCREG-CURRENT_LINE.
    ENDMODULE.
    Updating the internal table
    Method 1
    PROCESS AFTER INPUT.
    LOOP AT ITAB_REG.
    CHAIN.
    FIELD: ITAB_REG-REG,
    ITAB_REG-DESC.
    MODULE MODIFY_ITAB_REG ON CHAIN-REQUEST.
    ENDCHAIN.
    ENDLOOP.
    MODULE MODIFY_ITAB_REG INPUT.
    ITAB_REG-MARK = u2018Xu2019.
    MODIFY ITAB_REG INDEX TCREG-CURRENT_LINE.
    ENDMODULE.
    Method 2
    PROCESS AFTER INPUT.
    LOOP WITH CONTROL TCREG.
    CHAIN.
    FIELD: TCREG-REG,
    TCREG-DESC.
    MODULE MODIFY_ITAB_REG ON CHAIN-REQUEST.
    ENDCHAIN.
    ENDLOOP.
    MODULE MODIFY_ITAB_REG INPUT.
    MOVE-CORRESPONDING TCREG TO ITAB_REG.
    ITAB_REG-MARK = u2018Xu2019.
    MODIFY ITAB_REG INDEX TCREG-CURRENT_LINE.
    ENDMODULE.
    Updating the database
    MODULE USER_COMMAND_100.
    CASE OK_CODE.
    WHEN u2018SAVEu2019.
    LOOP AT ITAB-REG.
    CHECK ITAB_REG-MARK = u2018Xu2019.
    MOVE-CORRESPONDING ITAB_REG TO TCREG.
    UPDATE TCREG.
    ENDLOOP.
    WHEN u2026
    u2026
    ENDCASE.
    ENDMODULE.
    Hope this will solve your problem.
    Regards,
    Pavan.
    Edited by: PAVAN CHANDRASEKHAR GANTI on Aug 3, 2009 12:48 PM

Maybe you are looking for

  • Using SubReport to show Details of field grouped in Main Report

    Hi Experts I am creating a Crystal Report from BEx Query . In Report i have Created a group on Cost center field. & some other fields are in detail section. Suppose if i execute report then groups are A, B, C, D ...... Now further requirement  is  wh

  • Custom Error message for BI iview

    Hi guys, We have configured over 100 BI iviews in Portal which we do not want people to access for a certain period. A simple option we have thought is to remove all permissions on the System connector created for BI which would automatically deny us

  • ASN REPORT NEEDED

    Hi, I need an ASN report that shows ASN number the expected arrival date as well as material,vendor,quantity,current price and value. Can anyone please let me know if there is a standard report that can do this. If not can anyone propose me how this

  • 2G shuffle autofill with convert not working

    Since updating to iTunes 7.5 I've been unable to sync (autofill with convert to 128 kbps). It begins syncing but repeatedly goes back to the beginning and resyncs. It's been going three days straight without making it through. I'm running Vista and t

  • jsp:include in taglibs

    Can I use jsp includes inside the taglib