I am having touble logging alarm status in labview

I have written a vi that reads information from to data aquisition boards and compiles the info into a 1d boolean array(1x16) for its analog inputs and a 2d boolean array(9x23)for its digital inputs, I use a for loop and a case structure to index the arrays and return an alarm text if any of the booleans go HI. I want to display the alarm text on the front screen for each alarm that is Hi as well as save to disk and print. I have too small problems with my vi. Any alarms after the first one overwrite previouse alarm instead of adding to the current alarms, as well alarms continusly update making it impossible to save them as it would save every time the program cycles, I guess what I am asking is the
re any way for the alarm status to be updated with each new alarm only and not updating untill it finds another change of state.
thank you for any help or ideas
drw

For the alarm output, you can use shift registers and replace values if an alarm goes HI, letting the array pass trough if not. This way, only data passing to HI will write to the output, and won't overwrite it. You can save data everytime a bool goes high, so that only this makes data be saved. Attached there's a vi that gives some idea of what i mean.
Hope this helps
Attachments:
alarm.llb ‏46 KB

Similar Messages

  • WCS Alarm Status shows green but LAP is unplugged ?! Oper Staus shows Down

    Hello,
    we are operating a Cisco WLAN environment with 1242 and 1131 LAP. Some of them have been converted from AP to LAP.
    Now we took some LAP off the wall.
    They are now packed in a box in our storage room.
    But the WCS is showing a green Alarm Status for these LAP and as Oper Status Down.
    How can that be ?
    Is there a way to fix this problem, because we want to see the Alarm Status in Red.
    Thx for all your input.
    Best Regards
    Christian

    This is very interesting. If I try to put myself in the WCS developer's shoes, I think:
    - if you get an alarm for missing AP, then acknowledge the alarm, WCS has no reason to re-display the same alarm. This is precisely what Acknowledge is for, to say "don't bother me with this issue anymore".
    - Even if you manually remove the AP from WCS, it clearly keeps some memory of it, at least for a while. This is something you can clearly see if you run a report of any kind, WCS has to keep track of objects even if you remove them.
    My suggestion would be:
    - Unacknowledge the alarm, then delete it... acknowledging an alarm is probably not the best way to deal with removing an AP. You would use Aknowledge for alarms such as "your neighbour AP keep being detected as rogue, you can't remove your neighbour AP but don't want to hear about this warning anymore." You acknowledge the alarm, WCS keeps it in its database and remembers NOT to bother you with it anymore (exactly what happens in your case).
    For an AP you remove, I would not acknowledge the alarm, but simply delete it after having removed the AP. This removes the alarm from the WCS database.
    If you ever re-plug this AP to the network, WCS may remember it, but any new alarm about it will display.
    Hope it helps
    Jerome

  • LabVIEW DSC: How to get alarm status from the area?

    Colleagues,
    I have, lets say, 50 Shared Variables where alarming enabled. Some of these variables assigned to area, so I can get status of the entire area or acknowledge an entire area of alarms (prior to version 8.x there was groups of the tags).
    Now I would like to get alarm status from the entire area. How can I do it?
    In version 6 I was able to wire tag group to Get Alarm Summary Status. Now, in version 8, Alarm Status.vi can be wired to the array of the variables, but not to area. Is it possible to get all variables from the area?
    regards,
    Andrey.

    I am not sure if I should be posting my problem under this particular topic. I am having trouble understanding acknowledge alarm vi and what this vi is supposed to do is not clear to me yet.
    I have around 300 shared variables in my project and I have created a particular vi just to view the alarms that may pop up during runs. I created a main menu and this alarm vi can be accessed upon a button click in the main menu. Users get alarm alert based on sound configuration. Then he can navigate to the alarm vi and acknowledge the alarm. The alarm vi only contains alarm and event display found under DSC module.
    The problem is everytime I click the alarm button in the main menu, it takes around 2 minutes for the alarm vi to update which is very annoying and unsatisfactory in the middle of run. I am not sure why it happens and I haven't got any response from support yet. These shared variables are managed under 10 different library files that are set up based on different loops of the process (flow, pressure and so on).
    Then I looked into three alarm examples that ship with DSC module. None of these examples use acknowledge alarm vi. I implemented another vi similar to alarm demo vi in that example - containing multicolumn listbox. I created acknowledge event containing acknowledge button and used the acknowledge alarm vi under this event. Read vi alarm is under timeout event.
    When I click the acknowledge button  as soon as I see the alarm in multicolumn listbox, nothing happens - the color of font does not get changed to purple neither any alarms get acknowledged. I tried to aknowledge alarm by variable name or  alarms or alarm area, it does not give me anything. What is this acknowledge alarm supposed to do? I tried to find examples everywhere in the web that uses this particular vi and haven't found one yet. 

  • Having trouble logging onto iMessage

    Having trouble logging onto iMessage through my iPad air using my valid apple
    What do I do?

    Using FaceTime http://support.apple.com/kb/ht4319
    Troubleshooting FaceTime http://support.apple.com/kb/TS3367
    The Complete Guide to FaceTime + iMessage: Setup, Use, and Troubleshooting
    http://tinyurl.com/a7odey8
    Troubleshooting FaceTime and iMessage activation
    http://support.apple.com/kb/TS4268
    iOS: FaceTime is 'Unable to verify email because it is in use'
    http://support.apple.com/kb/TS3510
    Using FaceTime and iMessage behind a firewall
    http://support.apple.com/kb/HT4245
    iOS: About Messages
    http://support.apple.com/kb/HT3529
    Set up iMessage
    http://www.apple.com/ca/ios/messages/
    iOS and OS X: Link your phone number and Apple ID for use with FaceTime and iMessage
    http://support.apple.com/kb/HT5538
    How to Set Up & Use iMessage on iPhone, iPad, & iPod touch with iOS
    http://osxdaily.com/2011/10/18/set-up-imessage-on-iphone-ipad-ipod-touch-with-io s-5/
    Set Up Alert Sounds
    http://www.quepublishing.com/articles/article.aspx?p=1873027&seqNum=3
    Extra FaceTime IDs
    http://tinyurl.com/k683gr4
    Troubleshooting Messages
    http://support.apple.com/kb/TS2755
    Troubleshooting iMessage Issues: Some Useful Tips You Should Try
    http://www.igeeksblog.com/troubleshooting-imessage-issues/
    Setting Up Multiple iOS Devices for iMessage and Facetime
    http://macmost.com/setting-up-multiple-ios-devices-for-messages-and-facetime.htm l
    FaceTime and iMessage not accepting Apple ID password
    http://www.ilounge.com/index.php/articles/comments/facetime-and-imessage-not-acc epting-apple-id-password/
    Fix Can’t Sign Into FaceTime or iMessage iOS 7
    http://ipadtutr.com/fix-login-facetime-imessage-ios-7/
    FaceTime, Game Center, Messages: Troubleshooting sign in issues
    http://support.apple.com/kb/TS3970
    Unable to use FaceTime and iMessage with my apple ID
    https://discussions.apple.com/thread/4649373?tstart=90
    iOS 7 allows you to block phone numbers or e-mail addresses from contacting you via the Phone, FaceTime, or Messages
    http://howto.cnet.com/8301-11310_39-57602643-285/you-can-block-people-from-conta cting-you-on-ios-7/
    How to Block Someone on FaceTime
    http://www.ehow.com/how_10033185_block-someone-facetime.html
    My Facetime Doesn't Ring
    https://discussions.apple.com/message/19087457#19087457
    How to watch FaceTime calls on the big screen with Apple TV
    http://www.imore.com/daily-tip-ios-5-airplay-mirroring-facetime
    Send an iMessage as a Text Message Instead with a Quick Tap & Hold
    http://osxdaily.com/2012/11/18/send-imessage-as-text-message/
    To send messages to non-Apple devices, check out the TextFree app https://itunes.apple.com/us/app/text-free-textfree-sms-real/id399355755?mt=8
    How to Send SMS from iPad
    http://www.iskysoft.com/apple-ipad/send-sms-from-ipad.html
    How to Receive SMS Messages on an iPad
    http://yourbusiness.azcentral.com/receive-sms-messages-ipad-16776.html
    Apps for Texting http://appadvice.com/appguides/show/apps-for-texting
    You can check the status of the FaceTime/iMessage servers at this link.
    http://www.apple.com/support/systemstatus/
     Cheers, Tom

  • EPICS alarm status is incorrect

    I am using LV2010SP1 with the DSC module and EPICS Server/Client. I have used EPICS in DSC before, but only for passing values. Now I am interested in alarms and alarm status and I am getting strange results. I have attached a zip file with  a project that illustrates the problem. The server publishes a single integer, and in DSC I enabled alarms with the default thresholds: below 10 is LOLO, 10-25 is LOW, 25-75 is NO_ALARM, 75-90 is HIGH and above 90 is HIHI. When I run the server and look at the values of the shared variable and the EPICS Server variable using Distributed Server Manager then everything looks good. On the client side, though, the alarm status readings are messed up. The status changes at the correct levels, but the status reads wrong. LOLO shows up as STATE, LOW shows up as COS, HIGH shows up as LOW and HIHI shows up as LOLO! STATE and COS are not even legitimate options for status. Here is a screen shot of the Distributed System Manager display. Has anyone else encountered this problem? I have tried Int16 and Int32 with the same results. I will try DBL next, but eventually I need this to work for integers.
    Rich
    Attachments:
    EPICS Alarms.zip ‏19 KB

    Rich:
    So, it turns out that COS and STATE are valid values for the STAT field in EPICS, but they definitely don't make sense for the alarm states of the bound shared variables.
    (Brief mention of some of the STAT field values can be found on aps.anl.gov here)
    I've filed this under Corrective Action Request (CAR) #297362 with R&D. In the meantime, is it possible to use the server's STAT value (instead of the client's) as a workaround?
    Caleb Harris
    National Instruments | Mechanical Engineer | http://www.ni.com/support

  • Alarm status drawing iow: recolour JInternalFrame components

    Greetings,
    Please have a look at this picture. It's a low res snapshot of
    a few quite complicated components. Most of the functionality isn't
    visible nor relevant in the example. What you're looking at is a real time
    process of some sort. Things can go wrong in that process. In a previous
    version of my views I'd turn the background colour of some components
    red/yellow/green according to the 'alarm status' of the process. One of
    my customers suggested the idea of turning everything red/yellow/green
    inside those JInternalFrames (that's what you're looking at in the example).
    Of course one fool can ask more than a dozen of wise men can answer
    and I am not that wise, so my question is: how would one change the
    colour of all components that are part of a JInternalFrame (or any
    other container) such that the colour wouldn't be 100% opague but
    still visible by itself and still showing the information originally present
    in each individual component. iow, as if a transparent monochrome
    filter were positioned in front of that entire JContainer.
    In a naive way I like the idea; if the idea turns out to be too complicated
    to realize I'd be happy with visual alternatives also. (such as big arrows
    pointing to the JContainer where the alarm happened).
    Note that these appliations run in a 'factory' environment where people
    either hardly watch the screens or they watch them at quite a great
    distance. The changing colours should just attract their attention so they
    will walk/run/drive/ride to the screens for a second inspection.
    Any ideas are appreciated.
    kind regards,
    Jos

    Not sure I understand the question, but I keyed in on:
    as if a transparent monochrome filter were positioned in front of that entire JContainer.So maybe you could use a GlassPane:
    import java.awt.*;
    import java.awt.event.*;
    import javax.swing.*;
    public class GlassPaneTest extends JFrame
        public GlassPaneTest()
            final JComponent glassPane = new JComponent()
                public void paintComponent(Graphics g)
                    g.setColor( getBackground() );
                    g.fillRect(0, 0, getSize().width, getSize().height);
            glassPane.setOpaque( false );
            glassPane.setBackground( new Color(240, 20, 20, 100) );
            setGlassPane( glassPane );
            glassPane.addKeyListener( new KeyAdapter()
                public void keyPressed(KeyEvent e)
                    e.consume();
            glassPane.addMouseListener( new MouseAdapter()
                public void mousePressed(MouseEvent e)
                    e.consume();
            final JButton button = new JButton( "Click Me" );
            button.setMnemonic('c');
            button.addActionListener( new ActionListener()
                public void actionPerformed(ActionEvent e)
                       glassPane.setCursor(Cursor.getPredefinedCursor(Cursor.WAIT_CURSOR));
                       glassPane.setVisible( true );
                       glassPane.requestFocus();
                       Thread thread = new Thread()
                            public void run()
                                try { this.sleep(5000); }
                                catch (InterruptedException ie) {}
                                 glassPane.setVisible( false );
                                 glassPane.setCursor(null);
                    thread.start();
            getContentPane().add(new JLabel("NORTH"), BorderLayout.NORTH );
            getContentPane().add( button );
            getContentPane().add(new JTextField(), BorderLayout.SOUTH);
        public static void main(String[] args)
            GlassPaneTest frame = new GlassPaneTest();
            frame.setDefaultCloseOperation( EXIT_ON_CLOSE );
            frame.setSize(300, 300);
            frame.setLocationRelativeTo( null );
            frame.setVisible(true);
    }The Swing tutorial on [url http://java.sun.com/docs/books/tutorial/uiswing/components/rootpane.html]How to Use Glass Panes shows how you can also do a simple drawing (your arrow?) on the glass pane.

  • DSC 8.6.1 doesn't log alarms

    My alarms are not being logged in DSC 8.6.1.
    I can tell that the alarms are being properly generated when I monitor them in the Distributed System Manger.  In keeping with previous posts, I know that the MSSQL server is running in the taskbar.  I've also tried changing the permissions for NETWORK SERVICE in the citadel directory.
    When I try to monitor alarms in LV, it returns error code 1967386611: HIST_RunAlarmQueryCORE.vi, Citadel:  (Hex 0x8ABC100D) The given Citadel database is not currently configured to log alarms to a relational database.
    I also notice that the time stamp on all of the citadel files is not being updated with each alarm, so it really seems like the alarms not being logged.
    I have alarm logging enabled in all the appropriate places (at the variable, and in the library properties).
    When I check the alarm log history in MAX, there is nothing there.
    Thanks,
    Charlie

    Hello David,
    I have the same Problem with LabVIEW and DSC8.5.1 and, yes, SQL-Server 2000 was installed before I tried to install DSC the first time.
    But after I uninstalled the DSC, SQL-Server-Express 2005 and the old 2000-Version and reinstalled the complete DSC-Module it still didn't work. MAX doesn't display any error message but doesn't also show any data. ldf- and mdf-Files are not contained in the database folder.
    Right after installation and first reboot I get an Error-Message: IN MSDE Security Setup Error „NI MSDE is not accessable or currently logged
    user doesn't have sysadmin permissions“. I found a post for this issue, but the suggested solutions didn't work for me too ( http://forums.ni.com/ni/board/message?board.id=170&message.id=243298). And if I try to use the DSC's alarm-loging feature I end up with the Error:"...database is not currently configured to log alarms...".
    The DSC and the application we developed work fine on two other
    XP-Pro-PC's and I was surprised to get in trouble with installing it on
    the customers PC.
    The Windows XP Pro has been installed by our customer and I don't want to touch that installation. My user account has admin permissions. I have no clue how to fix this and I hope you have an idea what to try next.
    Thanks in advance,
    Thomas

  • I am having trouble logging in to my iTunes Account. When it ask mI am having trouble loe to verify my payment information. I check that everything is correct and it gives me this error message " Please contact iTune support to complete this transaction"?

    I am having trouble logging into my iTunes Account. When it ask me to verify my payment information. I verify that all the information is correct and press the done tab and get back this error message " Please contact iTunes support to complete this tranaction". What do I need to do to correct this problem because I can't buy anything with this problem? I have also made sure I have the latest version of iTunes.

    check all payment parts are filled in and u have endered you last 3 digs on back on card used to set up account
    if using an other computer make sure all fileds are right and filled in
    and u enter to itunes sec code

  • View alarm status of shared variable

    Hello:
    I need to know the alarm status (I mean, if the shared variable is currently alarmed) of some shared variables hosted in a Compact Fieldpoint Controller.
    I've seached for options on how to do this (like searching for a property through a property node of the SharedVariableIO class) but haven't found a succesful method to do it.
    Anybody knows how to do that?
    Thanks in advance!
    Robst.
    Robst - CLD
    Using LabVIEW since version 7.0

      Hola Robst, para ver las propiedades de una variable lo que necesitas hacer es habilitar el porperty node para que acepte como entradas las constantes de Variables Compartidas. Para que property node acepte esta referencia como entrada tienes que decirle que en clase es una variable compartida. Para seleccionar la clase da clic derecho sobre el nodo, y ahí aparece en el menu class. Después selecciona Shared Variable. Una vez que tengas la Shared Variable vas a tener todas las propiedades, sin embargo aquí no hay una propiedad que diga si está o no activa la alarma este nodo más bien te permite saber la configuración de la alarma y modificarla.
    Aquí hay tres opciones sencillas para sacar esto. La primera es utiliza solo una variable y conectala al Read Alarms, o Alarm Status a partir de aquí puedes saber si existe o no alarmas.
    Con el de Read Alarms si el arreglo regresa vacio es que no hay alarmas. Con el de alarm Status hay una elemento del Cluster que te indica que si hay alguna alarma.
    Ahora otra opción es utilizar Read Alarms y de ahí extraer cuales son las alarmas.
    Saludos
    Message Edited by BeCeGa on 12-18-2008 05:43 PM
    Benjamin C
    Senior Systems Engineer // CLA // CLED // CTD
    Attachments:
    Alarmas2.PNG ‏21 KB
    Alarms Variables.vi ‏22 KB

  • I have qualitynet either wired internet. I buy a card good for a month at a time, I can only log into one device at any one time.  Are there settings I can adjust on my airport express to allow all my devices to connect to wi-fi without having to log out.

    I have qualitynet either wired internet. I buy a card good for a month at a time, I can only log into one device at any one time.  Are there settings I can adjust on my airport express to allow all my devices to connect to wi-fi without having to log out of one devise before using another?

    Some Internet providers that limit access to a single device at a time do so by the device's hardware MAC address. If your ISP is one of those, you may be able to substitute the MAC address of your AirPort Express base station for the computer. I would suggest that you contact them to find out if this is allowable.

  • Hi, so I keep having problems logging onto the iTunes store in iTunes and I get this error message: "iTunes could not connect to the iTunes Store. An unknown error occurred (0x80090318) Make sure your network connection is active and try again."

    Hi,
    So I keep having problems logging onto the iTunes store in iTunes where an error message pops up saying: "iTunes could not connect to the iTunes Store. An unknown error occurred (0x80090318) Make sure your network connection is active and try again."
    How do I fix this?

    Hey thatssoivi,
    If you are having an issue with being unable to connect to the iTunes store, I would suggest that you troubleshoot using the steps in this article - 
    iTunes for Windows: iTunes Store connection troubleshooting - Apple Support
    Thanks for using Apple Support Communities.
    Be well,
    Brett L 

  • I have just upgraded from an iPhone 3Gs to an iPhone 5. I am trying to transfer all my content via icloud but having problems logging in - it keeps telling me the server is not responding. Nano sim hasn't yet been registered - does this affect things?

    i have just upgraded from an iPhone 3Gs to an iPhone 5. I am trying to transfer all my content via icloud but having problems logging in - it keeps telling me the server is not responding. Nano sim hasn't yet been registered - does this affect things?

    Have you activated your phone with your carrier yet?

  • Hello I want to know why am I hAving trouble logging on to craigslist

    Hello I wanted to know why am having trouble logging on to craigslist

    Hard to say without knowing what you are doing and what happens.

  • Having trouble logging in since last night, anyone else? Using iPad 3

    Having trouble signing in, buffering color squares, since last night...anyone else with same problem?

    Hi hipshots,
    Are you still having issues logging into Revel? If you are, could you please try logging in to adoberevel.com from a browser and see if you can log in.
    Thank you,
    Glenyse

  • Log version status in Integration Engine

    Hi,
    When montioring in Integration engine, couple of my messages are in 'Log version' status. These messages are in this status for the past two days.
    We are not able to cancel these messages also.
    What is the workaround solution to these messages.
    Thanks,
    Swapna

    It could be due to huge processing of message/data
    Do a complete cache refresh and check the same
    The solution in this thread points to XI BATCH.
    Log version in sxmb_moni in recever system (soap to proxy scenario)
    Edited by: Anusha  Ramsiva on Aug 6, 2008 2:57 PM

Maybe you are looking for

  • Cannot delete row in A/P Credit Memo

    hi experts              I created the A/P Invoice of Rs.580000 and partial payment Rs.120000 was made to this Invoice through Banking->OutgoingPayment now the balance due of this Invoice is Rs. 460000.       When this Invoice is copyto A/P Credit Mem

  • Java 1.4.2_04-b05 not working with netscape 7.1

    I am unable to get java to work with netscape 7.1 on Windows XP. I just get the puzzle icon when running the installation test. 1. I have de-installed and reinstalled java 1.4.2_04-b05 multiple times 2. Netscape/Plugins directory has npjpi142_04.dll,

  • End of Useful life for an asset

    Hello, Does anyone know if there is any standard report which states when the asset's useful life is going to end? Even if there is no standard report, does anyone know if this information is stored in any tables from which it can be extracted. Basic

  • How to connect to my stereo

    How can I stream video to a Sony Blu-Ray player (BDP-BX18) from my Airport Extreme?

  • User won't add to an AD security group

    Hello,      I've been scouring around the last few days and I've come up empty handed with an issue I'm having on a personal domain and I'm hoping someone here can point me in the right direction.      I have a domain controller set up in a lab envir