Hi expertsu2026u2026u2026
I am working on the scenario BDC Recording for fk01 and I am getting an error?
Error is : Different number of parameters in FORM and PERFORM(routine:BDC_FIELD,number of normal parameters:2,number of actual parameters:3).
Following is as follows source code.
report ZROHIT_BDC_FK01 no standard page heading line-size 255.
include bdcrecx1.
DATA:BEGIN OF ITAB OCCURS 0,
     LIFNR(16),
     BUKRS(4),
     KTOKK(4),
     ANRED(15),
     NAME1(35),
     SORTL(35),
     STRAS(3),
     ORT01(35),
     ORT02(35),
     LAND1(10),
     AKONT(10),
     END OF ITAB.
start-of-selection.
CALL FUNCTION 'UPLOAD'
* EXPORTING
*   FILENAME                      = 'D:\'
*   ACT_FILETYPE                  =
  TABLES
    DATA_TAB                      = ITAB
IF SY-SUBRC <> 0.
* MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
*         WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
ENDIF.
perform open_group.
LOOP AT ITAB.
perform bdc_dynpro      using 'SAPMF02K' '0105'.
perform bdc_field       using 'BDC_CURSOR'
                              'RF02K-KTOKK'.
perform bdc_field       using 'BDC_OKCODE'
                              '/00'.
perform bdc_field       using 'RF02K-LIFNR'
                              ITAB-LIFNR                  'ROHIT100'.
perform bdc_field       using 'RF02K-BUKRS'
                              ITAB-BUKRS                  '1000'.
perform bdc_field       using 'RF02K-KTOKK'
                              ITAB-KTOKK                  '0002'.
perform bdc_dynpro      using 'SAPMF02K' '0110'.
perform bdc_transaction using 'FK01'.
END LOOP.
perform close_group.
thanks in advance
Moderator message - Please respect the 2,500 character maximum when posting. Post only the relevant portions of code and please use code tags.
Edited by: Rob Burbank on Oct 7, 2009 10:34 AM

Hi,
The performs should be like this:
FORM bdc_dynpro USING program TYPE bdc_prog
                      dynpro TYPE bdc_dynr.
  CLEAR wa_bdcdata.
  wa_bdcdata-program = program.
  wa_bdcdata-dynpro = dynpro.
  wa_bdcdata-dynbegin = 'X'.
  APPEND wa_bdcdata TO gi_bdcdata.
ENDFORM .                    " bdc_dynpro
*&      FORM  BDC_FIELD
FORM to get the field name and field value
FORM bdc_field  USING fnam TYPE any
                      fval TYPE any.
  CLEAR wa_bdcdata.
  wa_bdcdata-fnam = fnam.
  wa_bdcdata-fval = fval.
  APPEND wa_bdcdata TO gi_bdcdata.
ENDFORM .                    " bdc_field
and make the changes as stated in your code:
LOOP AT ITAB.
perform bdc_dynpro      using 'SAPMF02K' '0105'.
perform bdc_field       using 'BDC_CURSOR'
                              'RF02K-KTOKK'.
perform bdc_field       using 'BDC_OKCODE'
                              '/00'.
>>perform bdc_field       using 'RF02K-LIFNR'
        >>                      ITAB-LIFNR                  " 'ROHIT100'.
>>perform bdc_field       using 'RF02K-BUKRS'
    >>                          ITAB-BUKRS                "  '1000'.
>>perform bdc_field       using 'RF02K-KTOKK'
    >>                          ITAB-KTOKK                  " '0002'.
perform bdc_dynpro      using 'SAPMF02K' '0110'.
perform bdc_transaction using 'FK01'.
END LOOP.
Regards,
Rajesh Kumar

Similar Messages

  • How to capture F4 help during bdc recording

    Hello All,
    I need one help to solve one of the requrimkents..
    In transaction Co02, user have to add the compoenents manually..but before user adds the components manually, i need to call the transaction co02, then i have do F4 help and fill the data for the user and then user will handle it manually...
    So till F4 help and filling the data in F4 help, i need to do through my program using bdc...when i try to do, F4 help is not captured in my recording..
    So please help me how to capture F4 help during BDC recording.
    Thanks in advance
    Sangeetha

    HI Sangeetha,
    I have one question for you!!!!
    Capturing F4 help  in BDC recording is secondary thing. First, If you want the user to select the value from the F4 help, then in that case user will have to run the BDC program in the foreground mode which is not possible and time consuming if your file is having more records (say >100). Then in that case will you prompt the user every time for selecting the component values, as many records there will be in the file to be uploaded??? I think it is not a way of handling or capturing the component values. I would prefer that pass the component values in the file which has to be uploaded.
    Please let me know if you still have some doubts on the same.
    Thanks
    VJ

  • Need help for bdc recording TC fp05

    Hi,
    My requirement is: I want to create a Payment lot using fp05 and then post   
                                it through a program.
    First i want to know is there any BAPI available to do that.
    I couldnt find any BAPI. That is why i did BDC Recording. The recording is working till Payment Lot creation. But after creation when i try to post the lot, it is giving status as "Direct Posting Stopped". Again if i come out of the program and then manually post it, it is working fine. But through program if i try to post it, it is giving status as "Direct Posting Stopped".
    Is this because we cannot Post a Payment Lot programatically or some Authorisation issue is there.
    Can anyone respond immediately
    Regards,
    Sheron

    Hi Raj,
    May be this can be useful.
    BAPI_INSPOPER_RECORDRESULTS
    You can search other in se37 BAPIINSP.
    Regards,
    Amit Mittal.

  • BDC recording for AS01

    hi all,
    how to do bdc recording for AS01.please send me step step by approach.

    Hi Satya,
    Welcome to SDN.
    Check this Sample program.
    REPORT ZASSET .
    INCLUDE ZASSET_INC .
    PARAMETERS: P_PCFILE LIKE RLGRAP-FILENAME.
    *PARAMETERS: P_FILE_S LIKE RLGRAP-FILENAME.
    PARAMETER : H_CHK AS CHECKBOX.
    "Proc Mode
    Include the BDC *
    **BDC DATA STUCTURE
    *DATA: BEGIN OF BDCDATA OCCURS 0.
    INCLUDE STRUCTURE BDCDATA.
    *DATA: END OF BDCDATA.
    messages of call transaction
    *DATA: MESSTAB LIKE BDCMSGCOLL OCCURS 0 WITH HEADER LINE.
    TYPE-POOLS
    TYPE-POOLS TRUXS.
    DATA IT_DATA1 TYPE TRUXS_T_TEXT_DATA.
    DATA : BEGIN OF IT_DATA OCCURS 0,
    INVZU(015),
    ANLKL(008),
    BUKRS(004),
    TXT50(100),
    SERNR(018),
    MENGE(018),
    INKEN(001),
    AKTIV(010),
    KOSTL(010),
    WERKS(004),
    STORT(010),
    ORD41(004),
    ORD42(004),
    EQANZ(001),
    LIFNR(010),
    AFASL(004),
    NDJAR(003),
    AFABG(010),
    ANLGR(012),
    ANLGR2(004),
    ANBTR01_01(016),
    ANBTR01_06(016),
    ANBTR01_16(016),
    TDATE(010),
    TCODE(004),
    TAMT(018),
    PERNR(012),
    KFZKF(015),
    SAP_ASSET(12),
    ERR_ASSET,
    END OF IT_DATA.
    DATA : BEGIN OF IT_DATA2 OCCURS 0,
    INVZU(015),
    TDATE(010),
    TCODE(004),
    TAMT(018),
    END OF IT_DATA2.
    DATA : BEGIN OF IT_DATA3 OCCURS 0,
    ITEM(003),
    INVZU(015),
    ANLKL(010),
    BUKRS(010),
    TXT50(050),
    SERNR(018),
    MENGE(018),
    INKEN(001),
    AKTIV(010),
    KOSTL(010),
    WERKS(004),
    STORT(010),
    ORD41(004),
    ORD42(004),
    EQANZ(001),
    LIFNR(010),
    AFASL(004),
    NDJAR(003),
    AFABG(010),
    ANLGR(012),
    ANLGR2(004),
    ANBTR01_01(016),
    ANBTR01_06(016),
    ANBTR01_16(016),
    TDATE(010),
    TCODE(004),
    TAMT(018),
    SAP_ASSET(12),
    ERR_ASSET,
    END OF IT_DATA3.
    SUB ASSET MASTER TABLE
    DATA : BEGIN OF IT_DATA_SUB OCCURS 0,
    INVZU_M(015),
    INVZU(015),
    BUKRS(004),
    TXT50(100),
    ANLHTXT(050),
    SERNR(018),
    MENGE(018),
    MEINS_007(003),
    XHIST_008(001),
    AKTIV(010),
    GSBER_011(004),
    KOSTL(010),
    STORT(010),
    ORD41(004),
    ORD42(004),
    EQANZ_016(001),
    LIFNR(010),
    LIEFE(030),
    NDJAR(003),
    NDPER(003),
    ANBTR01_01(016),
    ANBTR01_06(016),
    ANBTR01_16(016),
    BZDAT(010),
    BWASL(003),
    ANBTR01(016),
    ANLN1(012),
    ERR_SUB,
    SUB_CODE(012),
    ERR_SUB1,
    END OF IT_DATA_SUB.
    *& At selection-screen on value request for getting f4 help
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_PCFILE.
    PERFORM VALUE_REQUEST_P_FILE.
    *AT SELECTION-SCREEN ON VALUE-REQUEST FOR P_FILE_S.
    PERFORM VALUE_REQUEST_P_FILE_S.
    START OF SELECTION *
    START-OF-SELECTION.
    To Upload the flat file datas *
    PERFORM GET_DATA.
    PERFORM UP_LOAD.
    PERFORM SUB_UPLOAD.
    WRITE :/ 'FOLLOWING ASSETS CREATED'.
    WRITE:/ 'OLD ASSET'.
    WRITE: 20 'COMPANY'.
    WRITE: 30 'SAP CODE'.
    LOOP AT IT_DATA WHERE ERR_ASSET NE 'X'.
    WRITE :/ IT_DATA-INVZU,
    20 IT_DATA-BUKRS, 30 IT_DATA-SAP_ASSET.
    ENDLOOP.
    SKIP 2.
    WRITE :/ 'FOLLOWING SUB ASSETS CREATED'.
    WRITE:/ 'OLD ASSET'.
    WRITE: 16 'OLD SUB ASSET'.
    WRITE: 35 'COMPANY'.
    WRITE: 45 'SAP CODE'.
    WRITE: 60 'SUB ASSET'.
    LOOP AT IT_DATA_SUB WHERE ERR_SUB NE 'X' AND ERR_SUB1 NE 'X'.
    WRITE :/ IT_DATA_SUB-INVZU_M,
    16 IT_DATA_SUB-INVZU,
    35 IT_DATA_SUB-BUKRS, 45 IT_DATA_SUB-ANLN1, 60
    *IT_DATA_SUB-SUB_CODE.
    ENDLOOP.
    *& Form value_request_p_file
    FORM VALUE_REQUEST_P_FILE .
    CALL FUNCTION 'F4_FILENAME'
    EXPORTING
    PROGRAM_NAME = SYST-CPROG
    DYNPRO_NUMBER = SYST-DYNNR
    FIELD_NAME = 'x'
    IMPORTING
    FILE_NAME = P_PCFILE.
    ENDFORM. " value_request_p_file
    *& Form UP_LOAD
    text
    --> p1 text
    <-- p2 text
    FORM UP_LOAD .
    SORT IT_DATA BY INVZU.
    SORT IT_DATA2 BY INVZU.
    DATA : V_LEN1 TYPE I, V_LEN2 TYPE I, V_SUBSTR1(50) ,V_SUBSTR2(50).
    perform open_dataset using dataset.
    PERFORM OPEN_GROUP.
    LOOP AT IT_DATA.
    CONDENSE IT_DATA-TXT50.
    V_LEN1 = STRLEN( IT_DATA-TXT50 ).
    IF V_LEN1 > 50.
    V_SUBSTR1 = IT_DATA-TXT50+0(50).
    V_LEN2 = V_LEN1 - 50.
    V_SUBSTR2 = IT_DATA-TXT50+50(50).
    ELSE.
    V_SUBSTR1 = IT_DATA-TXT50.
    V_SUBSTR2 = ''..
    ENDIF.
    REFRESH BDCDATA.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '0105'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-BUKRS'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '/00'.
    PERFORM BDC_FIELD USING 'ANLA-ANLKL'
    IT_DATA-ANLKL.
    PERFORM BDC_FIELD USING 'ANLA-BUKRS'
    IT_DATA-BUKRS.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB02'.
    PERFORM BDC_FIELD USING 'ANLA-TXT50'
    V_SUBSTR1. "IT_DATA-TXT50.
    PERFORM BDC_FIELD USING 'ANLA-TXA50'
    V_SUBSTR2.
    PERFORM BDC_FIELD USING 'ANLA-SERNR'
    IT_DATA-SERNR.
    PERFORM BDC_FIELD USING 'ANLA-MENGE'
    IT_DATA-MENGE.
    *perform bdc_field using 'ANLA-INKEN'
    record-INKEN_006.
    PERFORM BDC_FIELD USING 'ANLA-INVZU'
    IT_DATA-INVZU.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-AKTIV'.
    PERFORM BDC_FIELD USING 'ANLA-AKTIV'
    IT_DATA-AKTIV.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB03'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLZ-PERNR'.
    PERFORM BDC_FIELD USING 'ANLZ-PERNR'
    IT_DATA-PERNR.
    PERFORM BDC_FIELD USING 'ANLZ-KOSTL'
    IT_DATA-KOSTL.
    PERFORM BDC_FIELD USING 'ANLZ-WERKS'
    IT_DATA-WERKS.
    PERFORM BDC_FIELD USING 'ANLZ-STORT'
    IT_DATA-STORT.
    IF IT_DATA-ANLKL = 'VHCL'.
    PERFORM BDC_FIELD USING 'ANLZ-KFZKZ'
    IT_DATA-KFZKF.
    ENDIF.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB04'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ORD42'.
    PERFORM BDC_FIELD USING 'ANLA-ORD41'
    IT_DATA-ORD41.
    PERFORM BDC_FIELD USING 'ANLA-ORD42'
    IT_DATA-ORD42.
    *perform bdc_field using 'RA02S-EQANZ'
    record-EQANZ_014.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB06'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-LIFNR'.
    PERFORM BDC_FIELD USING 'ANLA-LIFNR'
    IT_DATA-LIFNR.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB08'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLV-VSART'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=SELZ'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'RA02S-XAKPLA(02)'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '0195'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLB-AFASL'.
    IF IT_DATA-TCODE IS INITIAL.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTD'.
    ELSE.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTB'.
    ENDIF.
    PERFORM BDC_FIELD USING 'ANLB-ANLGR'
    IT_DATA-ANLGR.
    PERFORM BDC_FIELD USING 'ANLB-ANLGR2'
    IT_DATA-ANLGR2.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1100'.
    IF IT_DATA-TCODE IS INITIAL.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=BUCH'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(01)'
    IT_DATA-ANBTR01_01.
    IF H_CHK NE 'X'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(06)'
    IT_DATA-ANBTR01_06.
    ENDIF.
    ELSE.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTB'.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1200'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=BUCH'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-BZDAT(01)'
    IT_DATA-TDATE.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-BWASL(01)'
    IT_DATA-TCODE.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(01)'
    IT_DATA-TAMT.
    ENDIF.
    REFRESH MESSTAB.
    CALL TRANSACTION 'AS91' USING BDCDATA
    MODE H_MODE
    UPDATE 'S'
    MESSAGES INTO MESSTAB.
    PERFORM BDC_TRANSACTION USING 'AS91'.
    ENDLOOP..
    PERFORM CLOSE_GROUP.
    *perform close_dataset using dataset.
    ENDFORM. " UP_LOAD
    *& Form GET_DATA
    text
    --> p1 text
    <-- p2 text
    FORM GET_DATA .
    CALL FUNCTION 'TEXT_CONVERT_XLS_TO_SAP'
    EXPORTING
    I_TAB_RAW_DATA = IT_DATA1
    I_FILENAME = P_PCFILE
    TABLES
    I_TAB_CONVERTED_DATA = IT_DATA.
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    LOOP AT IT_DATA3.
    IF IT_DATA3-ITEM = '1'.
    MOVE-CORRESPONDING IT_DATA3 TO IT_DATA.
    APPEND IT_DATA.
    ELSEIF IT_DATA3-ITEM = '2'.
    IT_DATA2-INVZU = IT_DATA3-INVZU.
    IT_DATA2-TDATE = IT_DATA3-ANLKL.
    IT_DATA2-TCODE = IT_DATA3-BUKRS.
    IT_DATA2-TAMT = IT_DATA3-TXT50.
    APPEND IT_DATA2.
    ENDIF.
    ENDLOOP.
    IF NOT P_FILE_S IS INITIAL.
    CALL FUNCTION 'TEXT_CONVERT_XLS_TO_SAP'
    EXPORTING
    I_TAB_RAW_DATA = IT_DATA1
    I_FILENAME = P_FILE_S
    TABLES
    I_TAB_CONVERTED_DATA = IT_DATA_SUB.
    IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    ENDIF.
    ENDFORM. " GET_DATA
    FORM BDC_DYNPRO
    --> PROGRAM
    --> DYNPRO
    **FORM BDC_DYNPRO USING PROGRAM DYNPRO.
    CLEAR BDCDATA.
    BDCDATA-PROGRAM = PROGRAM.
    BDCDATA-DYNPRO = DYNPRO.
    BDCDATA-DYNBEGIN = 'X'.
    APPEND BDCDATA.
    **ENDFORM. " BDC_DYNPRO
    FORM BDC_FIELD
    --> FNAM
    --> FVAL
    **FORM BDC_FIELD USING FNAM FVAL.
    CLEAR BDCDATA.
    BDCDATA-FNAM = FNAM.
    BDCDATA-FVAL = FVAL.
    APPEND BDCDATA.
    **ENDFORM. "BDC_FIELD
    ***& Form bdc_transaction
    text
    -->TCODE text
    **FORM BDC_TRANSACTION USING TCODE.
    REFRESH MESSTAB.
    CALL TRANSACTION TCODE USING BDCDATA
    MODE H_MODE
    UPDATE 'S'
    MESSAGES INTO MESSTAB.
    **ENDFORM. " bdc_transaction
    *& Form VALUE_REQUEST_P_FILE_S
    text
    --> p1 text
    <-- p2 text
    FORM VALUE_REQUEST_P_FILE_S .
    CALL FUNCTION 'F4_FILENAME'
    EXPORTING
    PROGRAM_NAME = SYST-CPROG
    DYNPRO_NUMBER = SYST-DYNNR
    FIELD_NAME = 'x'
    IMPORTING
    FILE_NAME = P_FILE_S.
    ENDFORM. " VALUE_REQUEST_P_FILE_S
    *& Form sUB_upload
    text
    --> p1 text
    <-- p2 text
    ***FORM SUB_UPLOAD .
    DATA : V_LEN1 TYPE I, V_LEN2 TYPE I, V_SUBSTR1(50) ,V_SUBSTR2(50).
    LOOP AT IT_DATA_SUB WHERE ERR_SUB NE 'X'.
    CONDENSE IT_DATA_SUB-TXT50.
    V_LEN1 = STRLEN( IT_DATA_SUB-TXT50 ).
    IF V_LEN1 > 50.
    V_SUBSTR1 = IT_DATA_SUB-TXT50+0(50).
    V_LEN2 = V_LEN1 - 50.
    V_SUBSTR2 = IT_DATA_SUB-TXT50+50(50).
    ELSE.
    V_SUBSTR1 = IT_DATA_SUB-TXT50.
    V_SUBSTR2 = ''..
    ENDIF.
    REFRESH BDCDATA.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '0110'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ANLN1'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=MAST'.
    PERFORM BDC_FIELD USING 'ANLA-ANLN1'
    IT_DATA_SUB-ANLN1.
    PERFORM BDC_FIELD USING 'ANLA-BUKRS'
    IT_DATA_SUB-BUKRS.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB02'.
    PERFORM BDC_FIELD USING 'ANLA-TXT50'
    V_SUBSTR1. "IT_DATA_SUB-TXT50.
    PERFORM BDC_FIELD USING 'ANLA-TXa50'
    V_SUBSTR2. "IT_DATA_SUB-TXT50.
    ****perform bdc_field using 'ANLH-ANLHTXT'
    it_data_sub-ANLHTXT_004.
    PERFORM BDC_FIELD USING 'ANLA-SERNR'
    IT_DATA_SUB-SERNR.
    PERFORM BDC_FIELD USING 'ANLA-MENGE'
    IT_DATA_SUB-MENGE.
    ****perform bdc_field using 'ANLA-MEINS'
    it_data_sub-MEINS_007.
    ****perform bdc_field using 'RA02S-XHIST'
    it_data_sub-XHIST_008.
    PERFORM BDC_FIELD USING 'ANLA-INVZU'
    IT_DATA_SUB-INVZU.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-AKTIV'.
    PERFORM BDC_FIELD USING 'ANLA-AKTIV'
    IT_DATA_SUB-AKTIV.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB03'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLZ-GSBER'.
    ****perform bdc_field using 'ANLZ-GSBER'
    it_data_sub-GSBER_011.
    ****perform bdc_field using 'ANLZ-KOSTL'
    it_data_sub-KOSTL_012.
    PERFORM BDC_FIELD USING 'ANLZ-STORT'
    IT_DATA_SUB-STORT.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB04'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ORD41'.
    PERFORM BDC_FIELD USING 'ANLA-ORD41'
    IT_DATA_SUB-ORD41.
    PERFORM BDC_FIELD USING 'ANLA-ORD42'
    IT_DATA_SUB-ORD42.
    ****perform bdc_field using 'RA02S-EQANZ'
    it_data_sub-EQANZ_016.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB07'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-LIFNR'.
    PERFORM BDC_FIELD USING 'ANLA-LIFNR'
    IT_DATA_SUB-LIFNR.
    ****perform bdc_field using 'ANLA-LIEFE'
    IT_DATA_SUB-LIEFE.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB08'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-LEART'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=SELZ'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'T093T-AFBKTX(01)'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '0195'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLB-NDPER'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTD'.
    PERFORM BDC_FIELD USING 'ANLB-NDJAR'
    IT_DATA_SUB-NDJAR.
    PERFORM BDC_FIELD USING 'ANLB-NDPER'
    IT_DATA_SUB-NDPER.
    ****perform bdc_field using 'ANLB-AFABG'
    record-AFABG_029.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1100'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ANLN1'.
    IF IT_DATA_SUB-BWASL IS INITIAL.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=BUCH'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(01)'
    IT_DATA_SUB-ANBTR01_01.
    Accu deprn automatically calculated by system changed on 6th Aug.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(06)'
    IT_DATA_SUB-ANBTR01_06.
    ELSE.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTB'.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1200'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '/00'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-BZDAT(01)'
    IT_DATA_SUB-BZDAT.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-BWASL(01)'
    IT_DATA_SUB-BWASL.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(01)'
    IT_DATA_SUB-ANBTR01.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1200'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ANLN1'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=BUCH'.
    ****perform bdc_transaction using 'AS94'.
    ENDIF.
    REFRESH MESSTAB.
    CALL TRANSACTION 'AS94' USING BDCDATA
    MODE H_MODE
    UPDATE 'S'
    MESSAGES INTO MESSTAB.
    IF SY-SUBRC = 0.
    READ TABLE MESSTAB INDEX 1.
    IT_DATA_sub-SUB_CODE = MESSTAB-MSGV1.
    DATA AN1 TYPE ANLN1.
    DATA AN2 TYPE ANLN2.
    GET PARAMETER ID 'AN2' FIELD AN2.
    IT_DATA_SUB-SUB_CODE = AN2. "MESSTAB-MSGV1.
    MODIFY IT_DATA_SUB TRANSPORTING SUB_CODE.
    ELSE.
    IT_DATA_SUB-ERR_SUB1 = 'X'.
    MODIFY IT_DATA_SUB TRANSPORTING ERR_SUB1.
    ENDIF.
    REFRESH BDCDATA.
    ENDLOOP.
    ***ENDFORM. " sUB_upload
    ****& Form SUB_UPLOAD1
    text
    ***FORM SUB_UPLOAD1 .
    LOOP AT IT_DATA_SUB WHERE ERR_SUB NE 'X'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '0110'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ANLN1'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=MAST'.
    PERFORM BDC_FIELD USING 'ANLA-ANLN1'
    IT_DATA_SUB-ANLN1.
    PERFORM BDC_FIELD USING 'ANLA-BUKRS'
    IT_DATA_SUB-BUKRS.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB02'.
    PERFORM BDC_FIELD USING 'ANLA-TXT50'
    IT_DATA_SUB-TXT50.
    ****perform bdc_field using 'ANLH-ANLHTXT'
    it_data_sub-ANLHTXT_004.
    PERFORM BDC_FIELD USING 'ANLA-SERNR'
    IT_DATA_SUB-SERNR.
    PERFORM BDC_FIELD USING 'ANLA-MENGE'
    IT_DATA_SUB-MENGE.
    ****perform bdc_field using 'ANLA-MEINS'
    it_data_sub-MEINS_007.
    ****perform bdc_field using 'RA02S-XHIST'
    it_data_sub-XHIST_008.
    PERFORM BDC_FIELD USING 'ANLA-INVZU'
    IT_DATA_SUB-INVZU.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-AKTIV'.
    PERFORM BDC_FIELD USING 'ANLA-AKTIV'
    IT_DATA_SUB-AKTIV.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB03'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLZ-GSBER'.
    ****perform bdc_field using 'ANLZ-GSBER'
    it_data_sub-GSBER_011.
    ****perform bdc_field using 'ANLZ-KOSTL'
    it_data_sub-KOSTL_012.
    PERFORM BDC_FIELD USING 'ANLZ-STORT'
    IT_DATA_SUB-STORT.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB04'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ORD41'.
    PERFORM BDC_FIELD USING 'ANLA-ORD41'
    IT_DATA_SUB-ORD41.
    PERFORM BDC_FIELD USING 'ANLA-ORD42'
    IT_DATA_SUB-ORD42.
    ****perform bdc_field using 'RA02S-EQANZ'
    it_data_sub-EQANZ_016.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB07'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-LIFNR'.
    PERFORM BDC_FIELD USING 'ANLA-LIFNR'
    IT_DATA_SUB-LIFNR.
    ****perform bdc_field using 'ANLA-LIEFE'
    IT_DATA_SUB-LIEFE.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=TAB08'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-LEART'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '1000'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=SELZ'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'T093T-AFBKTX(01)'.
    PERFORM BDC_DYNPRO USING 'SAPLAIST' '0195'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLB-NDPER'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTD'.
    PERFORM BDC_FIELD USING 'ANLB-NDJAR'
    IT_DATA_SUB-NDJAR.
    PERFORM BDC_FIELD USING 'ANLB-NDPER'
    IT_DATA_SUB-NDPER.
    ****perform bdc_field using 'ANLB-AFABG'
    record-AFABG_029.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1100'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ANLN1'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=ALTB'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(01)'
    IT_DATA_SUB-ANBTR01_01.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(06)'
    IT_DATA_SUB-ANBTR01_06.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1200'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '/00'.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-BZDAT(01)'
    IT_DATA_SUB-BZDAT.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-BWASL(01)'
    IT_DATA_SUB-BWASL.
    PERFORM BDC_FIELD USING 'RALT_DYNP_STRUC-ANBTR01(01)'
    IT_DATA_SUB-ANBTR01.
    PERFORM BDC_DYNPRO USING 'SAPLALTD' '1200'.
    PERFORM BDC_FIELD USING 'BDC_CURSOR'
    'ANLA-ANLN1'.
    PERFORM BDC_FIELD USING 'BDC_OKCODE'
    '=BUCH'.
    ****perform bdc_transaction using 'AS94'.
    REFRESH MESSTAB.
    CALL TRANSACTION 'AS94' USING BDCDATA
    MODE H_MODE
    UPDATE 'S'
    MESSAGES INTO MESSTAB.
    IF SY-SUBRC = 0.
    READ TABLE MESSTAB INDEX 1.
    IT_DATA_sub-SUB_CODE = MESSTAB-MSGV1.
    DATA AN1 TYPE ANLN1.
    DATA AN2 TYPE ANLN2.
    GET PARAMETER ID 'AN2' FIELD AN2.
    IT_DATA_SUB-SUB_CODE = AN2. "MESSTAB-MSGV1.
    MODIFY IT_DATA_SUB TRANSPORTING SUB_CODE.
    ELSE.
    IT_DATA_SUB-ERR_SUB1 = 'X'.
    MODIFY IT_DATA_SUB TRANSPORTING ERR_SUB1.
    ENDIF.
    REFRESH BDCDATA.
    ENDLOOP.
    ***ENDFORM. " sUB_upload
    and one more thing i face some issues when doing bdc for AS01, so i use AS91 and AS92 for uploading by using LSMW (direct input method and recording method) and it was successful.(if u have to do coding go for BDC/BAPI or there is no coding better to choose LSMW (it is the easiest way) as of my knowledge, so before starting just analyze once which method is best for ur requirement.
    Reward Points for Useful Answers
    Thanks
    Naveen khan
    Message was edited by:
            Pattan Naveen

  • BDC recording not executing last OK code for order technical completion

    Hello!
    Regarding a QM requirement, I have created a rather simple BDC recording to change the activity type of an order to new ones (based on particular conditions not relevant here) on transaction IW32.
    However, if the order is technically complete, I have to cancel the technical completion, change the activity type, and then complete the order technically again (so it remains just the way it was before modification).
    The only order types relevant in the requirement are YM01 and YM02. For YM01, the BDC recording works like a charm. But when executing the proper recording for type YM02, the last OK code (i.e. pressing the OK button on the Complete subscreen) is ignored and the process remains incomplete: the orders are never completed technically again.
    Here is the recording:
    0     T     IW32     BS AA X   F
    SAPLCOIH                       101     X                                                                               
    0           BDC_OKCODE     /00
                                            0           CAUFVD-AUFNR     80000005
    SAPLCOIH                       3000     X                                                                               
    0           BDC_OKCODE      =WIAR
    SAPLCOIH                       3000     X                                                                               
    0           BDC_OKCODE     /00
                                            0           CAUFVD-ILART     206
    SAPLCOIH                       3000     X                                                                               
    0           BDC_OKCODE      =ARCH
    SAPLIWO1                           200             X                                                                               
    0           BDC_OKCODE      =WTER
                                            0           RIWO1-CLNOT     X
    Any help would greatly appreciated!
    Best regards,
    André Santos

    Leandro, thanks for the answer!
    The BDC recording does not work when executed visibly or step by step. After some extensive debugging, I realized that the final screen (the technical complete confirmation screen) is not an actual subscreen, even though it has its own number. That screen is actually generated by an FM, so apparently that's why it's ignored when the BDC is executed.
    I found a BAPI to replace that missing step: BAPI_ALM_ORDER_MAINTAIN. However, I'm having a hard time figuring out how to reference the orders I need it to complete. The FM asks for an IT_METHODS table and I couldn't tie the method to the orders:
    it_methods-refnumber = ???
    it_methods-objecttype = 'HEADER'. "That's what I found on the example, not sure whether this is right or not.
    it_methods-method = 'TECHNICALCOMPLETE'.
    it_methods-objectkey = ??? "Maybe the order number itself?
    APPEND it_methods.
    Has anyone used this BAPI before?
    Edited by: André Felipe Oliveira dos Santos on Oct 20, 2010 2:18 PM

  • CA01 Routing BDC Recording

    I have done a BDC recording for CA01, in the Setup Time and Machine Time column there was a warning message saying "Enter the Setup Time", we press enter and enter a value for both these fields. But the OK Code for this ENTER is not being recorded, and when we run the BDC Program, it comes and halts at this field with the warning message. How to avoid this warning message (or) overcome this problem..?
    Your help is highly appreciated.
    Thanks
    Murugappa

    Hi,
    I suggest to use the BI program with following details for the creation step by CA01 tx.:
    Objekt               0170   Arbeitsplan
    Methode              0001   Batch Input
    Programmname         RCPTRA01          
    Programmtyp          B   Batch-Input   
    Since the Routings have a complex data dependency on other objects and screen sequence, this would be helpful.
    May be the problem you are facing also could be addressed in this standard object. I have not faced any such message problem as I have loaded Normal / Standard routings, Quality routings in above method.
    Hope this helps.
    Best Regards, Murugesh AS

  • My wifes iphone was too full to record a video so I upgraded her cloud storage to 20g and did mine at same time. Cloud is showing 15g free storage butshe still cannot take any mor photos as "not enough memory" What is the point of paying for the extr

    My wifes iphone was too full to record a video so I upgraded her cloud storage to 20g and did mine at same time. Cloud is showing 15g free storage butshe still cannot take any mor photos as "not enough memory" What is the point of paying for the extr

    Hello Pushtheriver,
    After reviewing your post, I have located an article that can help in this situation. It contains a number of troubleshooting steps and helpful advice concerning iCloud storage issues:
    Get help using iCloud storage
    This may also help:
    Understanding iOS device capacity
    You can sync and download many different types of content on your device. Some types of content (such as music and videos) typically take more space than others (such as notes and books). The amount of space taken by an app depends on the app's purpose; complex or graphically intense apps usually take more space than simpler apps.
    If your device is near its capacity, you can remove some of the less used content to make room for more.
    Thank you for contributing to Apple Support Communities.
    Cheers,
    BobbyD

  • Problem in BDC Recording

    Hi I am having a problem in BDC Recording. My requirement is that when I input data in transaction fb02 to block the invoices, It shows a list of invoices. Now i need to double click that item(line) in which PK = 06 at runtime during bdc recording. During BDC recording it takes the line number on which we have clicked which is constant but i want it dynamic that if item 1 is having PK=6, that line should be double clicked and if item 3 is having PK=6, the third item should be double clicked to open another screen. Kindly help me... Thanks in advance.

    Hi Ravi,
    While writing your code that is in your code you know which line number is having the PK = 06, then you can use the same line number and add the code for double click after that.
    Regards,
    Atish

  • Material Master BDC recording

    hi gurus,
    i am trying to do a material master creation using BDC recording,
    i am new i dont know how to modify the code,
    the following is the code, please let me know how to make changes.
    report ZTEST95
           no standard page heading line-size 255.
    include bdcrecx1.
    parameters: dataset(132) lower case default
                                  'C:\Documents and Settings\Deskt'
                                & 'op\test95.txt'.
       DO NOT CHANGE - the generated data section - DO NOT CHANGE    ***
      If it is nessesary to change the data section use the rules:
      1.) Each definition of a field exists of two lines
      2.) The first line shows exactly the comment
          '* data element: ' followed with the data element
          which describes the field.
          If you don't have a data element use the
          comment without a data element name
      3.) The second line shows the fieldname of the
          structure, the fieldname must consist of
          a fieldname and optional the character '_' and
          three numbers and the field length in brackets
      4.) Each field must be type C.
    Generated data section with specific formatting - DO NOT CHANGE  ***
    data: begin of record,
    data element: MATNR
            MATNR_001(040),
    data element: MBRSH
            MBRSH_002(001),
    data element: MTART
            MTART_003(004),
    data element: REF_MATNR
            MATNR_004(040),
    data element: XFELD
            KZSEL_01_005(001),
    data element: MAKTX
            MAKTX_006(040),
    data element: MEINS
            MEINS_007(003),
    data element: MATKL
            MATKL_008(009),
    data element: SPART
            SPART_009(002),
    data element: MTPOS_MARA
            MTPOS_MARA_010(004),
    data element: BRGEW
            BRGEW_011(017),
    data element: GEWEI
            GEWEI_012(003),
    data element: NTGEW
            NTGEW_013(017),
          end of record.
    End generated data section ***
    start-of-selection.
    perform open_dataset using dataset.
    perform open_group.
    do.
    read dataset dataset into record.
    if sy-subrc <> 0. exit. endif.
    perform bdc_dynpro      using 'SAPLMGMM' '0060'.
    perform bdc_field       using 'BDC_CURSOR'
                                  'RMMG1-MATNR'.
    perform bdc_field       using 'BDC_OKCODE'
                                  '=ENTR'.
    perform bdc_field       using 'RMMG1-MATNR'
                                  record-MATNR_001.
    perform bdc_field       using 'RMMG1-MBRSH'
                                  record-MBRSH_002.
    perform bdc_field       using 'RMMG1-MTART'
                                  record-MTART_003.
    perform bdc_field       using 'RMMG1_REF-MATNR'
                                  record-MATNR_004.
    perform bdc_dynpro      using 'SAPLMGMM' '0070'.
    perform bdc_field       using 'BDC_CURSOR'
                                  'MSICHTAUSW-DYTXT(01)'.
    perform bdc_field       using 'BDC_OKCODE'
                                  '=ENTR'.
    perform bdc_field       using 'MSICHTAUSW-KZSEL(01)'
                                  record-KZSEL_01_005.
    perform bdc_dynpro      using 'SAPLMGMM' '4004'.
    perform bdc_field       using 'BDC_OKCODE'
                                  '/00'.
    perform bdc_field       using 'MAKT-MAKTX'
                                  record-MAKTX_006.
    perform bdc_field       using 'MARA-MEINS'
                                  record-MEINS_007.
    perform bdc_field       using 'MARA-MATKL'
                                  record-MATKL_008.
    perform bdc_field       using 'MARA-SPART'
                                  record-SPART_009.
    perform bdc_field       using 'MARA-MTPOS_MARA'
                                  record-MTPOS_MARA_010.
    perform bdc_field       using 'BDC_CURSOR'
                                  'MARA-BRGEW'.
    perform bdc_field       using 'MARA-BRGEW'
                                  record-BRGEW_011.
    perform bdc_field       using 'MARA-GEWEI'
                                  record-GEWEI_012.
    perform bdc_field       using 'MARA-NTGEW'
                                  record-NTGEW_013.
    perform bdc_dynpro      using 'SAPLSPO1' '0300'.
    perform bdc_field       using 'BDC_OKCODE'
                                  '=YES'.
    perform bdc_transaction using 'MM01'.
    enddo.
    perform close_group.
    perform close_dataset using dataset.
    thanks.

    Hi,
    It is better if the Material Master creation step is done by LSMW - Direct Input method with the following object:
    Object               0020   Material master
    Method               0000                 
    Program name         RMDATIND             
    Program type         D   Direct input
    Check the program documentation for more details.
    For a sample data file generation ( Sequential file ),  check the program RMDATGEN
    If the reqmt., is for a repetetive loading of Material Master you could schedule / execute the LSMW by following program: /SAPDMC/SAP_LSMW_INTERFACE.
    Hope this helps.
    Best Regards, Murugesh

  • How to use BDC recording in Workflow.

    Hi experts,
    Anyone kindly help me for the following case...
    If sales order gets created, mail has to be sent to every user. Also for that sales order, delivery should be created in background and again mail has to be sent to all users...
    I m clear with sending mail. but i m struggled while creating delivery in background. i dont know how to do this. I hav an idea that it can be created using BDC recording and this recording program can be called in our method which is created in our business object.
    How to create a single BDC recording to create sales order as well as creating delivery in background... Is it possible to do like this. Or is there any function module to create delivery in background with respect to sales order number?
    kindly give some suggestion and step by step procedure to do this...
    Thanks in advance...
    Regards
    Raaams...

    Hi Ram
    Check this BAPI once BAPI_OUTB_DELIVERY_CREATE_SLS.
    If this doesnt help do BDC recording and create a FM with the help of BDC recording. Please note that Call Transaction should happen in background otherwise your BDC wont work.
    Please revert back if you have any queries.
    Regards,
    Gautham Paspala

  • BDC recording for s_alr_87012090

    Hi Friends,
    My requirement :
    As we do vendor changes in xk02, the critical data like bank details, name and address are to be confirmed. so my client want, the changes done in address should not got to confirmation, so I want to do BDC recording for S_ALR_87012090 ( confir vendor changes ). and will check if only address changes are done then i will run these BDC recording .
    but i am unable to do recording.
    please help me out.
    regards
    Kumar M

    Hello Kumar M,
    What is the issue with it? Why cant you do the recording?
    BR,
    Suhas

  • Bdc recording for trancastion ME01

    Hi,
    Can u help me in BDC recording for transaction 'ME01' .
    I have no idea for transaction 'ME01'  & here i like to know how to handle table ctr during bdc recording?
    give sample code if possible.
    Thanks

    See the sample attached code for ME51 using table control.
    similarly record the same for ME01 and copy the TC logic from this.
    REPORT zmm_pr_upload_mat
    NO STANDARD PAGE HEADING
    LINE-SIZE 255.
    Standard Include for Selection Screen
    INCLUDE bdcrecx1.
    Internal Table for Upload Data
    DATA: BEGIN OF i_pr OCCURS 0,
    Header Screen
    sno(3), " SNo
    bsart(004), " PR Type
    epstp(001), " Item Category
    knttp(001), " Account Assignment
    eeind(010), " Delivery Date
    lpein(001), " Category of Del Date
    werks(004), " Plant
    lgort(004), " Storage Location
    ekgrp(003), " Purchasing Group
    matkl(009), " Material Group
    bednr(010), " Tracking No
    afnam(012), " Requisitioner
    Item Details
    matnr(018), " Material No
    menge(017), " Quantity
    badat(010),
    frgdt(010),
    preis(014), " Valuation Price
    waers(005), " Currency
    peinh(005),
    wepos(001),
    repos(001),
    sakto(010), " GL Account
    kostl(010), " Cost Center
    bnfpo(005),
    END OF i_pr.
    Internal Table for header Data
    DATA: BEGIN OF it_header OCCURS 0,
    sno(3), " SNo
    bsart(004), " PR Type
    epstp(001), " Item Category
    knttp(001), " Account Assignment
    eeind(010), " Delivery Date
    werks(004), " Plant
    lgort(004), " Storage Location
    ekgrp(003), " Purchasing Group
    matkl(009), " Material Group
    bednr(010), " Tracking No
    afnam(012), " Requisitioner
    END OF it_header.
    Internal Table for Item Data
    DATA: BEGIN OF it_item OCCURS 0,
    sno(3), " SNo
    matnr(018), " Material No
    menge(017), " Quantity
    preis(014), " Valuation Price
    sakto(010), " GL Account
    kostl(010), " Cost Center
    END OF it_item.
    Data Variables & Constants
    CONSTANTS : c_x VALUE 'X'. " Flag
    DATA : v_l(2), " Counter
    v_rowno(5), " Row No
    v_2(2), " Counter
    v_rows LIKE sy-srows, " Rows in TC
    v_field(45). " String
    Parameters
    PARAMETERS: p_file LIKE ibipparms-path. " Filename
    At selection-screen on Value Request for file Name
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_file.
    Get the F4 Values for the File
    CALL FUNCTION 'F4_FILENAME'
    EXPORTING
    program_name = syst-cprog
    dynpro_number = syst-dynnr
    IMPORTING
    file_name = p_file.
    Start of Selection
    START-OF-SELECTION.
    Open the BDC Session
    PERFORM open_group.
    Upload the File into internal Table
    CALL FUNCTION 'UPLOAD'
    EXPORTING
    filename = p_file
    filetype = 'DAT'
    TABLES
    data_tab = i_pr
    EXCEPTIONS
    conversion_error = 1
    invalid_table_width = 2
    invalid_type = 3
    no_batch = 4
    unknown_error = 5
    gui_refuse_filetransfer = 6
    OTHERS = 7.
    IF sy-subrc <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    SORT i_pr BY sno.
    LOOP AT i_pr.
    MOVE-CORRESPONDING i_pr TO it_item.
    APPEND it_item.
    CLEAR it_item.
    AT END OF sno.
    READ TABLE i_pr INDEX sy-tabix.
    MOVE-CORRESPONDING i_pr TO it_header.
    APPEND it_header.
    CLEAR it_header.
    ENDAT.
    ENDLOOP.
    SORT it_header BY sno.
    SORT it_item BY sno.
    v_rows = sy-srows - 6.
    Upload the Data from Internal Table
    LOOP AT it_header.
    Header Data
    PERFORM bdc_dynpro USING 'SAPMM06B' '0100'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'EBAN-BEDNR'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'EBAN-BSART'
    it_header-bsart.
    PERFORM bdc_field USING 'RM06B-EPSTP'
    it_header-epstp.
    PERFORM bdc_field USING 'EBAN-KNTTP'
    it_header-knttp.
    PERFORM bdc_field USING 'RM06B-EEIND'
    it_header-eeind.
    PERFORM bdc_field USING 'RM06B-LPEIN'
    it_header-lpein.
    PERFORM bdc_field USING 'EBAN-WERKS'
    it_header-werks.
    PERFORM bdc_field USING 'EBAN-LGORT'
    it_header-lgort.
    PERFORM bdc_field USING 'EBAN-EKGRP'
    it_header-ekgrp.
    PERFORM bdc_field USING 'EBAN-MATKL'
    it_header-matkl.
    PERFORM bdc_field USING 'EBAN-BEDNR'
    it_header-bednr.
    PERFORM bdc_field USING 'EBAN-AFNAM'
    it_header-afnam.
    Item Details
    v_l = 0.
    To add no. of rows
    v_2 = 0 .
    As the screen is showing 13 rows defaulted to 130
    v_rowno = 130 .
    LOOP AT it_item WHERE sno = it_header-sno.
    v_l = v_l + 1.
    IF v_l = 14 .
    IF v_2 = 12 .
    v_2 = 12 .
    v_l = 2 .
    From second time onwards it is displaying 12 rows only
    v_rowno = v_rowno + 120 .
    PERFORM bdc_dynpro USING 'SAPMM06B' '0106'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'RM06B-BNFPO'.
    PERFORM bdc_field USING 'RM06B-BNFPO'
    v_rowno.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    ELSE.
    V_2 initialized to 12 for second screen purpose
    v_2 = 12 .
    v_l = 2 .
    PERFORM bdc_dynpro USING 'SAPMM06B' '0106'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'RM06B-BNFPO'.
    PERFORM bdc_field USING 'RM06B-BNFPO'
    v_rowno .
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    ENDIF.
    ENDIF.
    PERFORM bdc_dynpro USING 'SAPMM06B' '0106'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    CLEAR v_field.
    CONCATENATE 'EBAN-MATNR(' v_l ')' INTO v_field.
    PERFORM bdc_field USING v_field it_item-matnr.
    CLEAR v_field.
    CONCATENATE 'EBAN-MENGE(' v_l ')' INTO v_field.
    PERFORM bdc_field USING v_field it_item-menge.
    PERFORM bdc_dynpro USING 'SAPMM06B' '0102'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'EBAN-PREIS'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '/00'.
    PERFORM bdc_field USING 'EBAN-PREIS'
    it_item-preis.
    PERFORM bdc_dynpro USING 'SAPMM06B' '0505'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'EBKN-SAKTO'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTE'.
    PERFORM bdc_field USING 'EBKN-SAKTO'
    it_item-sakto.
    Cost Center
    PERFORM bdc_dynpro USING 'SAPLKACB' '0002'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'COBL-KOSTL'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTE'.
    PERFORM bdc_field USING 'COBL-KOSTL'
    it_item-kostl.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=ENTE'.
    ENDLOOP.
    PERFORM bdc_dynpro USING 'SAPMM06B' '0106'.
    PERFORM bdc_field USING 'BDC_CURSOR'
    'RM06B-BNFPO'.
    PERFORM bdc_field USING 'BDC_OKCODE'
    '=BU'.
    Call The Transaction
    PERFORM bdc_transaction USING 'ME51'.
    ENDLOOP.
    Close the BDC Session
    PERFORM close_group.
    reward if useful
    Regards
    Vasu

  • BDC recording for transaction 'Me01'

    Hi,
    Can u help me in BDC recording for transaction 'ME01' .
    I have no idea for transaction 'ME01' .
    give sample code if possible.
    Thanks

    For creating source list you will check that purchasing view has been maintained for this material
    Source list for resticting, purcasing a material from a specific vendor only for the period specified in source list
    Regards,
    Amit R.

  • To display flatfile rec's under 1 Alternative BOM using BDc recording.

    Hi,
    I m trying to display flat file entire(i.e.. 4 rec's i m using) records vertically under one (Alternative BOM) for CS01-BOM using BDC recording method.
    Now i m tried with the following code,i m getting as one (Alternative BOM) for one ff record,by replacing one by one.
    But i want as vertically under one (Alternative BOM).
    Can anyone help me to overcome this.
    report ZBOM
    no standard page heading line-size 255.
    *include bdcrecx1.
    DATA: BEGIN OF bdc OCCURS 0,
    matnr(18),
    werks(4),
    stlan(1),
    END OF BDC.
    DATA: BEGIN OF BDC1 OCCURS 0,
    idnrk(18),
    MENGE(18),
    MEINS(3),
    postp(1),
    posnr(4),
    END OF bdc1.
    DATA: BEGIN OF BDCDATA OCCURS 0,
    matnr(18),
    werks(4),
    stlan(1),
    idnrk(18),
    MENGE(18),
    MEINS(3),
    postp(1),
    posnr(4),
    END OF BDCDATA.
    data ibdcdata type standard table of bdcdata WITH header line.
    *start-of-selection.
    CALL FUNCTION 'GUI_UPLOAD'
    EXPORTING
    FILENAME = 'C:\Documents and Settings\dilipkumar.b\Desktop\soft.txt'
    FILETYPE = 'ASC'
    HAS_FIELD_SEPARATOR = ','
    HEADER_LENGTH = 0
    READ_BY_LINE = 'X'
    DAT_MODE = ' '
    CODEPAGE = ' '
    IGNORE_CERR = ABAP_TRUE
    REPLACEMENT = '#'
    CHECK_BOM = ' '
    VIRUS_SCAN_PROFILE =
    NO_AUTH_CHECK = ' '
    IMPORTING
    FILELENGTH =
    HEADER =
    TABLES
    DATA_TAB = BDCDATA
    EXCEPTIONS
    FILE_OPEN_ERROR = 1
    FILE_READ_ERROR = 2
    NO_BATCH = 3
    GUI_REFUSE_FILETRANSFER = 4
    INVALID_TYPE = 5
    NO_AUTHORITY = 6
    UNKNOWN_ERROR = 7
    BAD_DATA_FORMAT = 8
    HEADER_NOT_ALLOWED = 9
    SEPARATOR_NOT_ALLOWED = 10
    HEADER_TOO_LONG = 11
    UNKNOWN_DP_ERROR = 12
    ACCESS_DENIED = 13
    DP_OUT_OF_MEMORY = 14
    DISK_FULL = 15
    DP_TIMEOUT = 16
    OTHERS = 17
    IF SY-SUBRC 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    *perform open_group.
    loop at bdcdata.
    perform bdc_dynpro using 'SAPLCSDI' '0100'.
    perform bdc_field using 'BDC_CURSOR'
    'RC29N-STLAN'.
    perform bdc_field using 'BDC_OKCODE'
    '/00'.
    perform bdc_field using 'RC29N-MATNR'
    'SOFTDRINKS'.
    perform bdc_field using 'RC29N-WERKS'
    'WIND'.
    perform bdc_field using 'RC29N-STLAN'
    '1'.
    perform bdc_field using 'RC29N-DATUV'
    '16.09.2008'.
    perform bdc_dynpro using 'SAPLCSDI' '0110'.
    perform bdc_field using 'BDC_OKCODE'
    '/00'.
    perform bdc_field using 'RC29K-BMENG'
    '1'.
    perform bdc_field using 'RC29K-STLST'
    '1'.
    perform bdc_field using 'BDC_CURSOR'
    'RC29K-EXSTL'.
    perform bdc_dynpro using 'SAPLCSDI' '0111'.
    perform bdc_field using 'BDC_CURSOR'
    'RC29K-LABOR'.
    perform bdc_field using 'BDC_OKCODE'
    '/00'.
    perform bdc_dynpro using 'SAPLCSDI' '0140'.
    perform bdc_field using 'BDC_CURSOR'
    'RC29P-POSTP(01)'.
    perform bdc_field using 'BDC_OKCODE'
    '=FCBU'.
    perform bdc_field using 'RC29P-IDNRK(001)'
    BDCDATA-IDNRK.
    perform bdc_field using 'RC29P-MENGE(001)'
    BDCDATA-MENGE.
    perform bdc_field using 'RC29P-MEINS(001)'
    BDCDATA-MEINS.
    perform bdc_field using 'RC29P-POSTP(001)'
    BDCDATA-POSTP.
    perform bdc_dynpro using 'SAPLCSDI' '0130'.
    perform bdc_field using 'BDC_OKCODE'
    '/00'.
    perform bdc_field using 'BDC_CURSOR'
    'RC29P-POSNR'.
    perform bdc_field using 'RC29P-POSNR'
    BDCDATA-POSNR. "'0010'.
    perform bdc_field using 'RC29P-IDNRK'
    BDCDATA-IDNRK. "'15'.
    perform bdc_field using 'RC29P-MENGE'
    BDCDATA-MENGE. "'1'.
    perform bdc_field using 'RC29P-MEINS'
    BDCDATA-MEINS. "'ml'.
    perform bdc_dynpro using 'SAPLCSDI' '0131'.
    perform bdc_field using 'BDC_OKCODE'
    '/00'.
    perform bdc_field using 'BDC_CURSOR'
    'RC29P-POTX1'.
    perform bdc_field using 'RC29P-SANKA'
    'X'.
    *perform bdc_transaction using 'CS01'.
    *perform close_group.
    CALL TRANSACTION 'CS01' USING IBDCDATA MODE 'A' UPDATE 'S'.
    REFRESH IBDCDATA.
    clear ibdcdata.
    endloop.
    Start new screen *
    FORM BDC_DYNPRO USING PROGRAM DYNPRO.
    CLEAR iBDCDATA.
    iBDCDATA-PROGRAM = PROGRAM.
    iBDCDATA-DYNPRO = DYNPRO.
    iBDCDATA-DYNBEGIN = 'X'.
    APPEND ibDCDATA .
    ENDFORM.
    Insert field *
    FORM BDC_FIELD USING FNAM FVAL.
    IF FVAL NODATA.
    CLEAR iBDCDATA.
    iBDCDATA-FNAM = FNAM.
    iBDCDATA-FVAL = FVAL.
    APPEND iBDCDATA .
    ENDIF.
    ENDFORM.

    Hi Dilip,
    Please change your code.
    I request you to please go through BDC tutorials before even starting to write the program.
    There are many online tutorials which can help you with.
    Also, search in SDN.. there you will get more than thousand results.. with the search term BDC.
    Take this suggestion seriously before nayone reports the moderators that u have been posting this thread daily without taking into consideration the previous replies.
    Regards,
    Vishwa.

  • Vendor Master (XK02) - Missing Screen fields in BDC recording.

    Hi All,
    I have extended IDOC type cremas03 to add some extended fields (sort1 and sort2) which are not in the standard IDOC.  In the exit ZXVSVU04, I plan on doing a call transaction to XK02 to update the required fields.  In my BDC recording, the two fields are not available, but are available when not in BDC both in change and create.   I have also tried recording FK02 and this behaves the same way. Is there a way of having these fields added so they are available in the BDC session?
    Best regards,
    James.

    Hi
    Really strange ...
    What all comes in the last section of the Web page, when you are using BBPMAINTINT transaction in SRM4.0?
    Look carefully, below the email option, there is an option for FTP as well.
    OR
    Is email option is coming as a drop-down list ?
    Hope this will help.
    Please reward suitable points.
    Regards
    - Atul

Maybe you are looking for

  • SALES ORDER LINE IS CANCELLED BUT DELIVERY DETAIL IS SHOING AS BACKORDERED

    SALES ORDER LINE IS CANCELLED BUT still the DELIVERY DETAIL IS showing as BACKORDERED it should be in cancelled status.The Sales order (only one ex:3904854) is cancelled , however order in shipping transactions screen indicates order is on backorder.

  • System crashes

    I can honestly say that since I've had my G5, I've always experienced problems of one type or another. Of course, most were user errors or conflicts that I could easily resolve. Recently, however, I have experienced crashes that have literally devast

  • Unable to open any folders in my HOTMAIL ACCOUNT inspite of logging in it

    I am able to log in to my HOTMAIL ACCOUNT, from the mozilla firefox. But unable to open or read or forward or delete any of the emails from the inbox and all the other folders. It seems there is a problem on the mozilla and not the hotmail account. A

  • HTC Touch 2 Alarm

    Hi All, new to this forum but seen some really neat ideas I can go play with. My question is the alarm on my phone. When I set it the alarm and switch the phone off it doesn't switch or wake up the phone and hence me!!  I have to leave the it on all

  • How to export a muse websiite into Dreamweaver?

    There are certain things I wan to add to my website that muse dose not offer. How do I export my muse sit to dream weaver?