Hi,
I have a problem regarding a generic delta extractor. The pointer stored in rsa7 (ROOSGENDLM table) is not UTC but system time. As standard tables store the timestamp using UTC format the delta extractor is not picking up the correct data.
Do you know a solution for this?

Hi,
Thanks for your reply. However I think that unfortunately this solution is not enough
For example:
I execute a delta. My TimeStamp is registered as UTC +2: 20080612160000. (Here I have the error, it should be in UTC)
Now I modify a record in R3 and it is registered with timestamp UTC: 20080612140000.
If I execute a delta it will take all the records higher than 20080612160000. Therefore my modification will never be uploaded.

Similar Messages

  • Generic Delta based off TimeStamp field is extracting full load

    I have a generic delta in place which is extracting a full load every time instead of only extracting the changes.
    I have created a generic delta based off a timestamp using a "Last Changed by" field of type Dec15, format YYYYMMDDHHMMSS.
    This datasource is populated via a FM which is only used to update two fields, all other fields (including last changed by field) are taken straight from the source table. Entries to the last changed by field are entered like this:
    20080310021530, then show up like this: 20,080,310,021,530.
    All relevent entries are showing in the tables ROOSOURCE, ROOSGENDLM, and ROOSPRMSC. There is also an entry in RSA7, status Green, Total = 1, and Status is showing the correct Delta relevent field as well as the correct timestamp of the last extraction.
    The entry in ROOSGENDLM contains:
    Current Pointer          Repeat Pointer
    20080320091503       20080320091653                               
    Yet every time I extract a "delta" from BI, it pulls a full load.
    Does anyone have an idea of how I can get the generic delta to work properly? I'm using 7.0 transformation/DTP. This field in BI uses a routine to convert the timestamp to a date field. Any help is greatly appreciated.
    Thanks!

    I think I found the issue. This timestamp is UTC timestamp, and until we implement SP13 (which is being onboarded in a week), this type of timestamp is not delta-relevent. Only timestamps on the local application server are delta-relevent pre-SP13, which can cause issues if the time is updated in a different timesone (to the east) of the application server.
    The following note corrects this issue:
    1073871
    Edited by: Cote Adams on Mar 20, 2008 4:59 PM

  • Generic Datasource Delta upload Issue

    Hi all,
    I have created a Generic Datasource for Solution Manager ODS 0crm_process_srv_h which contains the userstatus, transaction number, transaction desc and GUID of CRM Order Object (ods key field),only these fields.
      I have taken transaction number as delta field and it is as timestamp. But delta upload is not happening. If I give GUID or Status also delta upload is not happening . Please suggest which is the best way to give to delta upload.
    Thanks and Regards,
    SGK.

    Hi,
    in your case you need to create a function module as a extractor. Create a extract structure as well and add a timestamp field (lets call it zdeltahelp) to be used as the delta relevant field of the datasource. After successful init the last extraction timestamp will be passed to the fm and you can start selecting all resb entries for orders created and/or changed from that time on as well as the ones deleted (but therefore you need to read the change documents as well). For more information about generic extraction using fm search the forum or check out my business card. There you will find a link to a weblog about that issue.
    regards
    Siggi

  • Generic Delta with Timestamp Field

    Dear SDN Team,
    We changed one of our HR datasource from FULL to DELTA with Timestamp(TMSTMP)-Time Stamp(UTC).
    Which Delta we need to take Timestamp(Local) or Timestamp(UTC)
    Our Generic Datasource is based on Function Module.This data source contains HR Hours Data i.e Direct Hours & Indirect Hours.
    With interval settings has
    Safety Interval Upper Limit - 'Blank' .
    Safety Interval Lower Limit - 1800
    New status for Changed Records (Selected)
    It is a HR Generic Data Source.
    We are creating the records in PA30,PA40 and going to take the records from PA0000,PA0001
    Delta type for this DS is "AIE" as our delta type process for our DS.
    I am trying to load the INIT to Cube,but its not allowing to load,saying with 'AIE' delta type its not possible to load to cube.
    I changed the delta type to 'ADD' then the safety interval limits changed to
    Safety Interval Upper Limit - 1800 .
    Safety Interval Lower Limit - Blank.
    Additive Delta (selected)
    Is it possible to load the Generic Delta Time stamp to Cube?
    Please let us know what are the settings & delta type needs to be there to load the Generic Delta Timestamp to Cube.
    Your suggestions are really appreciated.
    Thanks and Kind Regards,
    Lakshman Kumar G

    Hi,
    We used TMSTMP filed with Data element TZNTSTMPS with data type DEC Length 15 in Function Module & Extract Structure.
    Default filed name is TIMESTAMP_UTC,Domain is TZNTSTMPS.
    Generic Delta -
    Filed name - TMSTMP
    Timestamp (UTC) selected
    With interval limits
    Safety Interval Upper Limit      1800
    Safety Interval Lower Limit
    New Status or Changed Records selected.
    Thanks and Kind Regards,
    lakshman

  • Generic delta extractors without timestamp!

    Hi,
    For a certain requirement, I have to develop generic extractors which should be delta capable. But unfortunately the source tables donu2019t have a timestamp; hence I canu2019t create delta enabled generic extractors using timestamp. Moreover most of the tables are standard SAP tables, which are used across different modules so it is not possible to introduce timestamp in these tables.
    I am working on extractors for Business Partners in SAP Transaction Banking.
    I have got couple of options:
    1) To use the change pointers by activating CNS service in source system. It is possible to activate the service and set up the segments for standard and custom tables, from where I need to extract the data.
    2) To develop the function module and create the generic extractors using delta queue functionality.
    Issues: In the first approach, I have created an extractor and it is possible to recognize the changed records. But the issue is I need some kind of flag which tracks the information regarding last successful delta extraction for an extractor based on change pointers and standard SAP table. I am not sure how does standard extractors maintains this status and picks up new/changed records in delta functionality. Not sure how to achieve this.
    In second approach I am not sure if it is possible to create generic extractors using delta queue and what are the complexities involved.
    If someone has already worked on these areas, any inputs are most welcome.
    Thanks and Regards,
    Amit

    Hi Amit,
    I haven't worked on SAP Transaction Banking but I hope you can get most of Business Partner data in standard extractors. Try to look for some.
    If you have to go for Generic extractor. there are 2 options:
    1. Use BTE
    [How To Create GDS which uses Delta Queue|https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/10b68b99-022e-2a10-999d-c4dc9ec24a59]
    2.Use FM based GDS
    [How to Create Generic Delta|https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/84bf4d68-0601-0010-13b5-b062adbb3e33]
    [Generic Delta Using Funtion Module |Re: Generic Delta Using Funtion Module]
    You can also look for some numeric pointer from RSO2.
    Hope it will help you...
    Regards,
    Ashish

  • Generic Delta extraction by Function module issue

    Hello Experts,
    Please help !!!
    I have problem for delta extraction by Function module.  For the full load, I wrote function module based on RSAX_BIW_GET_DATA_SIMPLE. It works fine.
    But I would like to have the delta load enabled. Therefore, I modified the datasource, add a delta specific field u2018ztimestampu2019, which type is calendar day.
    Then I create a function module based on template u2018RSAX_BIW_GET_DATAu2019, as this support the upload mode. But when I test this datasource in RSA3, no matter itu2019s full load or initial delta load, it always send me an error, u201CErrors occurred during the extractionu201D.
    I had some debug, and found that there is no value  for i_isource when my function module is called. Therefore it raised the exception.
    But I do not have the chance to debug my code for the delta logic, can somebody help to check?
    I also check the entries in ROOSOURCE,
    For my datasource ZTRNREC_FM_DELTA, The DELTA value is u2018AIEu2019, and extraction method is u2018F2u2019, should I change them to DELTA= u2018Du2019 and extraction method to u2018F1u2019? Where to change?
    FUNCTION ZRSAX_TRAININGREC_DELTA.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SBIWA_S_INTERFACE-REQUNR
    *"     VALUE(I_ISOURCE) TYPE  SBIWA_S_INTERFACE-ISOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SBIWA_S_INTERFACE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SBIWA_S_INTERFACE-INITFLAG OPTIONAL
    *"     VALUE(I_UPDMODE) TYPE  SBIWA_S_INTERFACE-UPDMODE OPTIONAL
    *"     VALUE(I_DATAPAKID) TYPE  SBIWA_S_INTERFACE-DATAPAKID OPTIONAL
    *"     VALUE(I_PRIVATE_MODE) OPTIONAL
    *"     VALUE(I_CALLMODE) LIKE  ROARCHD200-CALLMODE OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SBIWA_T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SBIWA_T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZTRN_REC_TIME OPTIONAL
    *"      E_T_SOURCE_STRUCTURE_NAME OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    The input parameter I_DATAPAKID is not supported yet !
    Example: InfoSource containing TADIR objects
    Auxiliary Selection criteria structure
      DATA: l_s_select TYPE sbiwa_s_select.
    Maximum number of lines for DB table
      STATICS: l_maxsize TYPE sbiwa_s_interface-maxsize,
              S_S_IF TYPE SRSC_S_IF_SIMPLE,
              S_COUNTER_DATAPAKID LIKE SY-TABIX.
    Parameter I_PRIVATE_MODE:
    Some applications might want to use this function module for other
    purposes as well (e.g. data supply for OLTP reporting tools). If the
    processing logic has to be different in this case, use the optional
    parameter I_PRIVATE_MODE (not supplied by BIW !) to distinguish
    between BIW calls (I_PRIVATE_MODE = SPACE) and other calls
    (I_PRIVATE_MODE = X).
    If the message handling has to be different as well, define Your own
    messaging macro which interprets parameter I_PRIVATE_MODE. When
    called by BIW, it should use the LOG_WRITE macro, otherwise do what
    You want.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF i_initflag = sbiwa_c_flag_on.
    Initialization: check input parameters
                    buffer input parameters
                    prepare data selection
    The input parameter I_DATAPAKID is not supported yet !
    Invalid second initialization call -> error exit
        IF NOT g_flag_interface_initialized IS INITIAL.
          IF 1 = 2. MESSAGE e008(r3). ENDIF.
          log_write 'E'                    "message type
                    'R3'                   "message class
                    '008'                  "message number
                    ' '                    "message variable 1
                    ' '.                   "message variable 2
          RAISE error_passed_to_mess_handler.
        ENDIF.
    Check InfoSource validity
        CASE i_isource.
          WHEN 'ZTRNREC_FM_DELTA'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e009(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      i_isource            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Check for supported update mode
        CASE i_updmode.
          WHEN 'F'.
          WHEN 'D'.
          WHEN 'R'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE e011(r3). ENDIF.
            log_write 'E'                  "message type
                      'R3'                 "message class
                      '011'                "message number
                      i_updmode            "message variable 1
                      ' '.                 "message variable 2
            RAISE error_passed_to_mess_handler.
        ENDCASE.
    Check for obligatory selection criteria
        APPEND LINES OF i_t_select TO g_t_select.
    Fill parameter buffer for data extraction calls
        g_s_interface-requnr    = i_requnr.
        g_s_interface-isource   = i_isource.
        g_s_interface-maxsize   = i_maxsize.
        g_s_interface-initflag  = i_initflag.
        g_s_interface-updmode   = i_updmode.
        g_s_interface-datapakid = i_datapakid.
        g_flag_interface_initialized = sbiwa_c_flag_on.
    Fill field list table for an optimized select statement
    (in case that there is no 1:1 relation between InfoSource fields
    and database table fields this may be far from beeing trivial)
        APPEND LINES OF i_t_fields TO g_t_segfields.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call      OPEN CURSOR + FETCH
                   Following Calls FETCH only
      LOOP AT G_T_SELECT INTO L_S_SELECT
            WHERE FIELDNM = 'ZTIMESTAMP'.
      ENDLOOP.
          IF G_COUNTER_DATAPAKID = 0.
            IF L_S_SELECT-LOW = '' AND L_S_SELECT-HIGH = ''.
            OPEN CURSOR WITH HOLD G_CURSOR FOR
                SELECT (g_t_fields)
                FROM ZTRN_REC_TIME.
            ELSE.
              OPEN CURSOR WITH HOLD G_CURSOR FOR
                SELECT (g_t_fields)
                FROM ZTRN_REC_TIME
                WHERE ZTIMESTAMP >= L_S_SELECT-LOW
                  AND ZTIMESTAMP  <= L_S_SELECT-HIGH.
            ENDIF.
          ENDIF.
      FETCH NEXT CURSOR G_CURSOR
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE E_T_DATA
                   PACKAGE SIZE S_S_IF-MAXSIZE.
        IF SY-SUBRC <> 0.
          CLOSE CURSOR G_CURSOR.
          RAISE NO_MORE_DATA.
        ENDIF.
        S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
      ENDIF.
    ENDFUNCTION.
    I found some similar issue in this forum by link
    Generic Extractor Delta Function Module code, but still I could not get clear answer.
    Can you please help me:
    1)     why there is no value for i_source , how to fix it?
    2)     For the delta logic for ztimestemp, is it correct?
    3)     Need I modify the entries in ROOSOURCE ?
    Thanks a lot !!!

    Hello Andre,
            Thanks a lot for your help. I did some change , but still does not work. Could you please help check.
    Now the source code are the following, It's based on the RSAX_BIW_GET_DATA_SIMPLE, as you confirm that this also supply the update mode (full, initial delta, delta).
    FUNCTION RSAX_BIW_GET_DATA_TRAININGREC1.
    ""Local Interface:
    *"  IMPORTING
    *"     VALUE(I_REQUNR) TYPE  SRSC_S_IF_SIMPLE-REQUNR
    *"     VALUE(I_DSOURCE) TYPE  SRSC_S_IF_SIMPLE-DSOURCE OPTIONAL
    *"     VALUE(I_MAXSIZE) TYPE  SRSC_S_IF_SIMPLE-MAXSIZE OPTIONAL
    *"     VALUE(I_INITFLAG) TYPE  SRSC_S_IF_SIMPLE-INITFLAG OPTIONAL
    *"     VALUE(I_READ_ONLY) TYPE  SRSC_S_IF_SIMPLE-READONLY OPTIONAL
    *"     VALUE(I_REMOTE_CALL) TYPE  SBIWA_FLAG DEFAULT SBIWA_C_FLAG_OFF
    *"  TABLES
    *"      I_T_SELECT TYPE  SRSC_S_IF_SIMPLE-T_SELECT OPTIONAL
    *"      I_T_FIELDS TYPE  SRSC_S_IF_SIMPLE-T_FIELDS OPTIONAL
    *"      E_T_DATA STRUCTURE  ZTRN_REC_TIME OPTIONAL
    *"  EXCEPTIONS
    *"      NO_MORE_DATA
    *"      ERROR_PASSED_TO_MESS_HANDLER
    Auxiliary Selection criteria structure
      DATA: L_S_SELECT TYPE SRSC_S_SELECT.
    Maximum number of lines for DB table
      STATICS: S_S_IF TYPE SRSC_S_IF_SIMPLE,
    counter
              S_COUNTER_DATAPAKID LIKE SY-TABIX,
    cursor
              S_CURSOR TYPE CURSOR.
    Select ranges
    RANGES:
            L_R_ZTIMESTAMP FOR ZTRN_REC_TIME-ZTIMESTAMP.
    Initialization mode (first call by SAPI) or data transfer mode
    (following calls) ?
      IF I_INITFLAG = SBIWA_C_FLAG_ON.
    Initialization: check input parameters
                    buffer input parameters
                    prepare data selection
    Check DataSource validity
        CASE I_DSOURCE.
          WHEN 'ZTRNREC_FM'.
          WHEN OTHERS.
            IF 1 = 2. MESSAGE E009(R3). ENDIF.
    this is a typical log call. Please write every error message like this
            LOG_WRITE 'E'                  "message type
                      'R3'                 "message class
                      '009'                "message number
                      I_DSOURCE   "message variable 1
                      ' '.                 "message variable 2
            RAISE ERROR_PASSED_TO_MESS_HANDLER.
        ENDCASE.
        APPEND LINES OF I_T_SELECT TO S_S_IF-T_SELECT.
    Fill parameter buffer for data extraction calls
        S_S_IF-REQUNR    = I_REQUNR.
        S_S_IF-DSOURCE = I_DSOURCE.
        S_S_IF-MAXSIZE   = I_MAXSIZE.
    Fill field list table for an optimized select statement
    (in case that there is no 1:1 relation between InfoSource fields
    and database table fields this may be far from beeing trivial)
        APPEND LINES OF I_T_FIELDS TO S_S_IF-T_FIELDS.
      ELSE.                 "Initialization mode or data extraction ?
    Data transfer: First Call      OPEN CURSOR + FETCH
                   Following Calls FETCH only
    First data package -> OPEN CURSOR
        IF S_COUNTER_DATAPAKID = 0.
          LOOP AT S_S_IF-T_SELECT INTO L_S_SELECT WHERE FIELDNM = 'ZTIMESTAMP'.
          MOVE-CORRESPONDING L_S_SELECT TO L_R_ZTIMESTAMP.
          APPEND L_R_ZTIMESTAMP.
          ENDLOOP.
    Determine number of database records to be read per FETCH statement
    from input parameter I_MAXSIZE. If there is a one to one relation
    between DataSource table lines and database entries, this is trivial.
    In other cases, it may be impossible and some estimated value has to
    be determined.
         IF L_S_SELECT-LOW = '' AND L_S_SELECT-HIGH = ''.
            OPEN CURSOR WITH HOLD S_CURSOR FOR
            SELECT (S_S_IF-T_FIELDS)
            FROM ZTRN_REC_TIME.
            ELSE.
            OPEN CURSOR WITH HOLD G_CURSOR FOR
            SELECT (S_S_IF-T_FIELDS)
            FROM ZTRN_REC_TIME
            WHERE ZTIMESTAMP >= L_S_SELECT-LOW
            AND ZTIMESTAMP <= L_S_SELECT-HIGH.
         ENDIF.
        ENDIF.                             "First data package ?
    Fetch records into interface table.
      named E_T_'Name of extract structure'.
        FETCH NEXT CURSOR S_CURSOR
                   APPENDING CORRESPONDING FIELDS
                   OF TABLE E_T_DATA
                   PACKAGE SIZE S_S_IF-MAXSIZE.
        IF SY-SUBRC <> 0.
          CLOSE CURSOR S_CURSOR.
          RAISE NO_MORE_DATA.
        ENDIF.
        S_COUNTER_DATAPAKID = S_COUNTER_DATAPAKID + 1.
      ENDIF.              "Initialization mode or data extraction ?
    ENDFUNCTION.
    I think it already includes the important statements you suggested.
    I test this FM in RSA3, for the Full load mode, it works fine. Also if I checked the debug mode in execution , it will stop in the code and let me debug.
    But when I choose other mode, like 'initializion of the delta transfer'  or simulation of initial delta, I always get error 'error occurs  during the extraction' .. even I choose debug mode, but it could not enter the code for debug..
    Till now I did not see any parameter or value for the upload mode..
    Another questions is that, in RSO2, I define Ztimestamp as my delta field.. But , can I add other field as selection condition in the datasource definition, and has its range table in this function module ?
    Should I change the entries in ROOSOURCE for this datasource ??
    Please let me know your feedback, do you have some concret example for generic delta extraction ?
    Thanks a lot !

  • Issue with generic extraction (Generic Delta)

    I have one more issue with Generic Delta Extraction. Here I selected the field related to my requirement but when I am trying to save I am getting error Still OLTP have errors.
    I need some help when we select generic delta wht are the settings. Like now I am working on Inventory Management.
    Please Some one help me as soon as possible.
    Thanks In advance.....
    Regds
    SDR.

    Hi ,
    I think there are some of the Keyfigure fields which needs 0Unit or 0Currency field to be present in the Extract Structure but they are not present . Check All unit of measure and Currency unit fields are not hidden .
    Regards,
    Vijay.

  • Generic delta issue - INITIALIZATION - Missing some records

    Hello all,
    We have create a specific table on our SAP system (4.6C) and a specific datasource.
    We have customized a generic delta process (DELTA SPECIFIC FIELD = Last Change Date type DATS).
    The table contains 38 records.
    When we launch a full loading all the records are extracted (that is to say 38 records).
    When we launch a INIT loading (with no selection) only 6 records are extracted.
    The generic TYPE for delta field is CALENDAR DAY.
    Why the init loading doesn't load all the data contain in the table ?
    Some of you have already meet such problem ?
    The table structure can be the reason of this problem ?
    Points will be done
    Edited by: Marc Marquez on Jul 24, 2008 10:56 AM

    This test is already done, the problem is on ECC system.
    On RSA3 side the behaviour is the same than in BW
    FULL loading is ok (all records are extracted)
    INIT loading is ok but most of the records are not loaded (6 instead of 38)
    Christophe
    Edited by: Marc Marquez on Jul 28, 2008 3:18 AM

  • Problem in extracting Generic Delta Records

    Hi BW Experts,
    I have an issue. I am using Generic Extractor using View from Tables CATSCO and CATSDB. At the time of  Generic Delta, I am using the field PERNR(Personal Number) to use Generic Delta. I am using Time Stamp. For this I have selected Safety Interval Upper Limit 100 seconds.But now I am testing whether we get delta records or not. But I am not getting records to BW. They are changed in R/3. So please guide me whether I should use Calday or Time Stamp . How can  I get delta records to BW.For testing , I am executing InfoPackage immediately after changes in R/3 like for two or three minutes. Once I will be sure on getting records to BW, then I can move to Production where we execute process chain at 1:00 a.m
    there I can use Calday giving Safety Interval Upper Limit as 1 day. Considering the above factors please guide me .
    I will be thankful for solving my issue.

    PERNR doesn't contain a date right?  so timestamp tells the system PERNR is a date field...  That will never work.
    What kind of value does PERNR contain, is it an incremental value that adds up at every new entry?
    Generic delta needs a field that changes in a way that can be predicted.

  • EKBE table for Generic Delta

    Hi Gurus,
    Good Day to all. I just like to inquire some details for creating generic datasource with delta enabled. I have created a view table with fields from EKBE table, and created generic datasource that reads the view table I have created from EKBE, now it needs delta process with CPUDT as delta specific field name, seeing the data type of CPUDT, it is DATS with 8 length.
    I would like to assure if what will be use as marker of delta, timestamp utc, timestamp local, calendar day and numeric pointer?
    And if I use one of the above, what settings that needs to be use for the safety interval upper and lower limit?
    Thank you for your inputs and really appreciate it.

    Hi,
    use the CALDAY as a generic delta pointer.
    i would like to recommend as: Safety Interval for Upper Limit as 1 and Safety Interval for lower Limit as ZERO
    i think your are using the DSO as a staging layer no worry about duplicates.
    Thanks,
    Phani.

  • Generic delta extraction using function module

    Hi.
    I have a generic datasource , extraction being performed by a function module. The extraction works fine in full update mode. The extract structure has a timestamp field.
    I have enabled generic delta using this field(i.e., marked this field in RSO2). I understand that with this setting, I should be able to get delta data when I do a delta request. But it does not seem to happen.
    I checked the ROOSPRMSC table for the last(local) timestamp stored there. Now when I do the delta upload I expect to see only those records which are younger than the stored timestamp of last upload.
    But I still get the entire set of records.
    Questions are :
    1. Do I need to explicitly code for fetching the delta in the extractor ?
    2. If not, what could be the reason why generic delta is not working ?
    Thanks and regards,
    Anuradha

    Hi GFV,
    I read-up all the forum entries on this topic but could not find anything specifically dealing with my problem. I have browsed through the how-to paper on generic delta as well.
    I am quite sure that we don't need any special coding in the extrator for generating delta generically. Even the how-to paper does not mention that.
    I have used the FM RSAX_BIW_GET_DATA_SIMPLE as a template
    for my extractor(as suggested by F1 help in RSO2). This FM does not even have the i_updmode flag in its interface. 
    Thus this function module always does full extraction and I expect the system to take care of delta using the timestamp field.
    Are these assumptions incorrect ?
    Regards,
    Anuradha

  • Generic Delta with numeric pointer (Without safety interval and no field)

    Hi
    We have problems with Generic Delta extraction. Our previous Dev has created the data source with numeric pointer as the data source without any safety interval and without any field for numeric pointer selection even we have the date field (creation and change dates in view)....
    He created the generic delta with numeric pointer and Additive delta selection on top of view (EKKO,EKPO and EKKN). So we are missing lot of records. Now I need to fix this asap, I have done generic delta with timestamp and cal day with change/creation date.
    Now in order to fix our delta loads should I use the cal day as the delta pointer with change or creation date already available or is it ok to use numeric pointer with additive delta and safety lower limit as 10 or 20 with upper limit blank?
    Also Should I use any field in the field nm section or is it ok to leave it blank ? Please advice...
    Note: I checked the missing delta records in ECC and the change timing is in the afternoon and our load time is only night...We also have several other data sources with same settings (numeric with no safety and no field) but it is not giving any issues.
    Thanks
    Edited by: ganesh uttitti on Jan 26, 2011 10:33 PM

    Hi Ganesh  ,
      I'm a little confuse,Why are you not use LO Delata for it?

  • Generic Delta Extraction (Bill Plan Data)

    Hi BW Gurus,
    We need to cerate data source from Bill plan extractor.
    Please note that there is no SAP standard extractor for the bill plan data. So that is the reason we are using generic extractor (RSO2). We were using sales order delta extract program to find out the changes in bill plan data and there was routine in that extract which updated the custom table. But, soon they have to get rid of this design, because they observed that all the changes being done to bill plan were not being captured in the sales order delta extract. So, they have to go ahead with a full extract instead of the delta extract for bill plan data. Now we need to create design so we can do a delta extract on the billing plan data.
    Please advice me ASAP.
    In Advance Many thanks for your help.
    Regards
    SAP Team

    You could use the date field instead , you could have a lower safety interval and then when you do the delta again the records included in the lower safety interval are included. As for delta with timestamp , I have a question what is the timestamp used for delta - is it UTC Timestamp or the date and time concatenated together. UTC Timestamp did not seem to work for me and I did not have the luxury of having a concatenated timestamp.
    When I checked the base tables for delta maintenance , I found both timestamps and am confused as to what timestamps to use.
    Arun
    P.S I have a current delta with changed date and a lower safety interval of 1 day and it is working fine so far.

  • Generic delta with function module

    Hi Gurus,
    Is it possible to create a generic DataSource with delta support using function module following the queue delta mechanism (u can get some function moduel in MCEX function group, and check the outbound delta queue before and after update in transaction smq1.
    I can store the delta data using qRFC and collective update mechanism. but I don't know how to create a generic data with delta and how to attach a rfc destination (& logical system) to the data source. The Source system information is stored in the table "ROOSGEN".  Is there any configuration setting required to do the same.
    Regards,
    Jugal

    Jugal,
    What I understand you to be asking is if it is possible to create a generic delta extractor which uses the delta queue. If this indeed is your question the answer is yes.
    First you need to create your data source so it is visible via tx RSA5 and need to make sure that the delta type (ie ABR, AIM)is set appropriately for the datasource.
    The issue however is determining from where you will associate your delta hook (when will you write to the queue)? I have in the past utilized BTE's, Business Transaction Events to write information out to the delta queue, you can see a list of available BTE's in your system via tx FINF.
    Once you find a place to write your deltas from you call the below FM with the appropriate datasource.
    RSC1_TRFC_QUEUE_WRITE.
    Once you have done this the standard BW extractor for deltas will pull the information from the delta queue. But from what I understand you just want to know how to associate the data with the delta and that is the FM listed above.
    Hope this helps,
    Cheers,
    Scott
    > Hi Gurus,
    >
    > Is it possible to create a generic DataSource with
    > delta support using function module following the
    > queue delta mechanism (u can get some function moduel
    > in MCEX function group, and check the outbound delta
    > queue before and after update in transaction smq1.
    > I can store the delta data using qRFC and collective
    > update mechanism. but I don't know how to create a
    > generic data with delta and how to attach a rfc
    > destination (& logical system) to the data source.
    > The Source system information is stored in the table
    > "ROOSGEN".  Is there any configuration setting
    > required to do the same.
    >
    > Regards,
    > Jugal

  • Problem in getting Generic Delta records to BW

    Hi BW Gurus,
    I have got one issues with which I have been struggling a lot for several days . i.e
    I am extracting data from R/3 using Generic Extractor (View) from CATSCO and CATSDB. At the time of delta, I tried using Personal  No with Time Stamp giving Upper limit as 1800 seconds. I executed Infopackage in BW immediately. But it didn't work out. So plz guide me how I can get Delta Records to BW. Or should I do any  necessary factors apart from these in Generic Delta Screen (RSO2).
    It is very urgent.
    I will be thankful for solving this issue.

    Hey I am "Intros" again,,
    I am sorry man for giving the wrong T-code mistakenly in my last reply..
    To solve the proble...the whole process is same what I told u before..
    But... you got to go to T-Code :  BD87   , then execute the IDocs manually to bring them in to BW
    identify your IDocs which are missing in Monitor screen, then goto BD87 and select those IDocs and click execute... )you can search the IDoc's based on selection conditions)
    I hope this will help u...
    cheers man..
    ---Intros

Maybe you are looking for

  • Pictures in camera roll erased after restart of phone

    Need help with this. First note that this is not a syncing with computer/itunes matter. All pictures that I take and that are stored in the camera roll are gone after I restart the iPhone 3G (even if I dont connect to a computer after the pictures ar

  • How to create a multiple existing users in exch 2013

    Hi  Do you know how to add a multiple existing users in Exchange 2013,only permits add one user at time. I need add 200 users. In exchange 2007 and 2010 this feature is possible through the management console It´s possible in Exchange 2013?

  • Using motion clips for overlays in dvd studio?

    does anyone know if you can use a motion file,(eg. highlight for a dvd menu button), in dvd studio pro for overlays? like if you had a menu set up, and you need to put a highlght on a button for it's selected state? thanks

  • How to alphabetically sort albums and folders within a folder

    Much to my dismay, I discovered that iPhoto will not alphabetically sort folders or albums that are within a folder. It will only sort folders and albums (in separate groups) that are at the "root" level beneath the ALBUMS label. I used "iPhoto Folde

  • WIFI DROPS OUT AFTER MOUNTAIN LION UPDATE

    Since upgrade to mountain lion my wifi keeps dropping out after sleep i have ipad and that is ok.