JMS in Enterprise with multiple VM's fail

Hi
Im running 9.0.3 enterprise on Windows 2000. I have a servlet that dumps messages into a JMS queue which invokes a MDB.
The Server is running 2 VM's in the same island.
If I chooses the restart option with enterprise manager interface, all works well until the JMS part gets used.
Only every second request/message gets handled!!
Choosing a shutdown and then a startup sometimes resolve this.
Choosing a total server reboot resolves this problem.
Any know workaround to this ?
Tks
Andre

Hi - even more
Looking at the server.log file on a working one, it seems impossible to define a correct port in the jms.xml file as the server starts on any one of the ports from 3201 to the upper limit defined!
What must be in the jms.xml file as 9217 doesn't work as in the OC4J standalone version?
4/24/03 9:06 AM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#232660#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3103&JMS:sdtias1#3203
4/24/03 1:50 PM 9.0.3.0.0 Started
4/24/03 1:58 PM 9.0.3.0.0 Stopped (JVM termination)
4/24/03 1:58 PM 9.0.3.0.0 Started
4/24/03 1:58 PM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#970662#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3102&JMS:sdtias1#3202
4/24/03 1:58 PM 9.0.3.0.0 Stopped (JVM termination)
4/24/03 2:02 PM 9.0.3.0.0 Started
4/24/03 2:02 PM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#316011#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3105&JMS:sdtias1#3204
4/24/03 3:51 PM 9.0.3.0.0 Stopped (JVM termination)
4/24/03 3:56 PM 9.0.3.0.0 Started
4/24/03 3:56 PM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#322739#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3105&JMS:sdtias1#3204
4/24/03 4:09 PM 9.0.3.0.0 Stopped (JVM termination)
4/24/03 4:09 PM 9.0.3.0.0 Started
4/24/03 4:09 PM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#453811#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3101&JMS:sdtias1#3201
4/24/03 4:09 PM 9.0.3.0.0 Stopped (JVM termination)
4/24/03 4:13 PM 9.0.3.0.0 Started
4/24/03 4:13 PM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#323857#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3105&JMS:sdtias1#3204
4/25/03 7:26 AM 9.0.3.0.0 Started
4/25/03 7:26 AM Forced or abrupt (crash etc) server shutdown detected, starting recovery process...
4/25/03 7:26 AM Recovery completed, 0 connections committed and 0 rolled back...
4/25/03 7:26 AM Published an event: C_10.0.67.244.79f9d8.f49a578d51.-8000#p2.sdtias1.mtn.co.za#313000#home#home#default_island&sdtias1&HTTP:sdtias1#3000&RMI:sdtias1#3105&JMS:sdtias1#3204

Similar Messages

  • Jms message filtering with multiple fields

    Hi
    Can anybody please tell me how to do message filtering with multiple fields. i using jdeveloper11.1.1.4.0 , soa11g suite and weblogic 10.3.
    previously i used JMSType property for one field filtering.
    and is it possible to invoke jms adapter with our own properties (adding property to jms).
    thanks,
    Sourbh

    thanks atheek
    i worked with the same and it helped me a lot i can share one more link that will help.
    http://forums.oracle.com/forums/thread.jspa?messageID=9650255&#9650255
    Regards,
    Sourbh.

  • Win7 install with multiple/all the FAILS! Satellite P750 (PART NO. PSAY3A-02T001)

    Laptop: Toshiba Satellite P750 (PART NO. PSAY3A-02T001)
    Installing: Windows 7 Home Premium SP1 (64 bit)
    Background: Laptop is around 2-3 years old now. Formatting and installing a fresh copy of Win7. Doing this for a close friend.
    Issue #1: Using the "Windows 7 USB DVD Download Tool" off the microsoft website, I attemped to install Win7 via USB drive (had so many issues before using this tool ). It boots to USB perfectly and starting going through the installation options. When it gets to "Where do you want to install Windows?"  (creating and seleting HDD partitions) I hit a major road-block!
    p.s. USB in USB2.0 as I originally tried 3.0 and coudln't even make it that far....
    I get the Error "Setup was unable to create a new system partition or locate an existing systm partition. See the Setup log files for more information." Basically the Primary disk is created but the system disk wont.
    p.s. The HDD still does show up and worked before this all. it's not a failed HDD.
    I've tried (most of these were "Fixes" I found on forums that never worked):
    1. Creating different size partitions, multiple partitions, leaving GB's of "Unallocated Space" hoping it will create a system partition. Didn't work.....
    2. Formating the whole HDD using Command-line and wiping it completely clean. Honestly, this was stupid because now I cannot even go back! Didn't work.....
    3.Changing BIOS settings and praying it will work. Most of the BIOS settings these fixes told me to change, aren't actaully on this Toshiba model. I even restart to default settings. Didn't work....
    4. Even tried a "load Drivers" fix I found. The fix asked for a SATA driver, but I got every driver just incase. Not a single driver even appeared on the "Select the driver to be installed" screen. Unticked the "hide drivers.." box also... So that didn't work either...
    At this point I was pretty mad so I went and purcahsed some DVD-RW's to burn the ISO onto and try that instead.
    Issue #2: Using the same tool as before, I installed Win7 onto a DVD. I then ran the DVD on my PC to test and the setup.exe showed up. I then put the DVD in the Toshiba laptop and using F12 to select "ODD        TSSTcorp CDDVDw TS-L633F" (the other options were "HDD/SSD, USB and LAN).
    p.s. The DVD drive lights up and I can hear it reading the disc (normal slight humm).
    I then get:
    "Intel UNDI, PXE-2.1 (build 083)
    Copyright (C) 1997-2000 Intel Corporation
    This product is covered by one or more of the following patents:
    US5,307,459, US5,434,872, UD5,732,094, US6, 570, 884, US6,115,776 and
    US6,327,625
    Realtek PCI Express Gigabit Ethernet Controller Series v2.35 (06/14/10)
    PXE-E61: Media test failure, check cable
    PXE-M0F: Exiting PXE ROM.
    Reboot and Select proper Boot device
    or Insert Boot Media in selected Boot Device and Press a key_"
    To me, this is the LAN controller boot, but it didn't even read the disk.
    I've tried (and again, most of these were "Fixes" I found on forums that never worked):
    1. Changing Boot priorities and settings. I even tried to disable LAN boot in BIOS (but you cannot on this model). Didn't work..
    2. Yelling at it and holding myself back from hitting it with a hammer. Still attempting..
    3. Praying to a higher power. Didn't work...
    Ideas I have left that may work:
    1. Downloading and burning a different ISO. maybe even trying 32bit. (was 64bit before starting)
    2. Waiting for someone much smarter than me to reply on this post and help me!
    3. Telling my friend that "It's not my problem, while I run off into the sunset!"
    PLEASE SOMEONE HELP! This is doing my head in!
    and yes, I've tried turning it off and on again 

    oh my **bleep**ing god...... I am so mad right now! 95% butthurt infact!
    MY RAGE IS STRONG!
    Just found out off the owner that the DVD drive doesn't work.. 
    SO! The DVD drive doesn't work and it seems like the only way to install Win7. I have a feeling that this model doesn't do USB very well....
    will an external DVD drive work for this? or some I find someone with a toshiba that has the same model dvd drive inside and swap them for an hour while I do it...
    or should I try LAN... havn't one LAN install in a home environment before..

  • JMS to communicate with multiple 3rd party systems

    Hi,
    I'm fairly new to JMS and I need to build a system where I communicate with several third party systems through JMS.
    Basically what I need is some sort of synchronous message system, as I need the result to display on my webpage.
    In this scenario, I was wondering what is the most common design here, in terms of queues or topics.
    Would it be normal for each system to have a input and output queue, or is it more practical that I provide a outbound topic and an inbouw queue that these systems could use?
    I know how I can set this up, but I just wanted to ask if it is normal practice to ask a third party to connect to your own JMS system, rather than connecting to their queue/topic?
    Thanks,
    Steven

    Hi,
    I'm fairly new to JMS and I need to build a system where I communicate with several third party systems through JMS.
    Basically what I need is some sort of synchronous message system, as I need the result to display on my webpage.
    In this scenario, I was wondering what is the most common design here, in terms of queues or topics.
    Would it be normal for each system to have a input and output queue, or is it more practical that I provide a outbound topic and an inbouw queue that these systems could use?
    I know how I can set this up, but I just wanted to ask if it is normal practice to ask a third party to connect to your own JMS system, rather than connecting to their queue/topic?
    Thanks,
    Steven

  • Configure Enterprise Manager with multiple Listener

    Configure Enterprise Manager with multiple Listener
    I have created 2 listeners and connected my database with both the listeners. If I stop one listener then it automatically uses second listener vice versa. But facing problem in case of enterprise manager. If i stop first listener which is on 1521 port it is not connecting to another listener which is on 1522 port.
    any help ?

    Your potential problem is Enterprise Manager simply doesn't KNOW about that second listener. You can easily verify that when you look at the monitored targets.
    Enterprise Manager also reconstructs automagically it's own tnsnames.ora! So, it doesn't connect to second -completely redundant and useless - listener, because the tnsnames.ora entry on the Management Sever is incorrect.
    Simply because you didn't made sure OEM could discover the second -completely redundant and useless- listener.
    I notice you apparently don't want to read documentation. Yet the only way to work successfully with Oracle, and to become independent, is to read that documention.
    Apart from that you should be able to find agentca.bat on your OS with one command, so, yes, I pointed you to the documentation, yes, you can find agentca.bat.
    Sybrand Bakker
    Senior Oracle DBA

  • When iam loading multiple datatargets with single datasource request failed

    when iam loading multiple datatargets with single datasource request failed
    i want to delete the  bad request at a time in all datatargets

    Hi Neeraj,
    The only thing you can do is go in to theMonitor screen of that IP and select the datatargets from the Monitor screen.In the next screen you can see all the targets included in the IP at the top.But the only bad thing is you have to manually delete the Bad request only from each target.
    Regards
    Sandeep

  • DataSocket fails intermittently with multiple NICs enabled using LV7.1

    Using LV7.1 and Datasocket v4.2, I was intermittently (but quite often) having problems reading and writing to the datasocket server (primarily from the server side). My application should read the value in the item and upon finding a specific string it should immediately follow it with a write of a default string. However, it can find the same string multiple times and not complete the write. Logging the errors from the write shows that no error is occurring. The client is not at fault because it only writes the string once every few minutes. I was able to finally show that by disabling the extra NIC on my system running the datasocket server that the connection seems to operate reliably. Both NICs
    were set to static IP addresses, but only one was connected. I do have the program writing to "dstp://localhost/UUT" as opposed to a specific IP address (not sure if it matters).
    With Labview6.1 I did not have this problem. It was only after I re-compiled my application with LV7.1 that I started having issues.

    Philip,
    I do not feel I am running out of bandwidth since I have run it successfully on 1Gbit NIC connections on a P4 2.4GHz system as well as a 10/100Gbit NIC on an old 650MHz system with LV6.1. I only do two writes per variable (on up to 8 variables) once every few minutes. I did not seem to be a re-entrant VI issue.
    I have created two VIs which should allow you to recreate the failing conditions with multiple NICs enabled. It responds very quickly with one NIC enabled, but when one or two more NICs is enabled, it gets very slow to respond and has some timeouts.
    One VI is the writer, the other is the reader. Start both VIs and start all 8 reader loops. Then you can consecutive
    ly click on all 8 sender loops. Doing this with and without multiple NICs enabled should show you the problem.
    Note: I think the issue I was talking about in earlier posts about getting multiple strings back before it wrote out "Loop" was due to the fact that the writes were not occurring quickly enough and the reads were happening multiple times. Therefore, in these VIs, I revised the read and close timeouts to -1.
    I think it would be best if you could call me so we can discuss this issue. If you can email me, I will send you my contact information if you don't already have access to it.
    Attachments:
    ReadSocket_Multiple_MSHv1.vi ‏360 KB
    WriteSocket_Multiple_MSHv1.vi ‏216 KB

  • B2B Inbound File with Multiple Transactions failing

    Hi ,
    Problem Summary: When the inbound file is coming with multiple transactions (combination of 997 and non-997) ,
    If the 997 is the FIRST transaction in file, B2B is processing only 997 and remaning transactions are getting rejected.
    Where as if the 997 is the LAST transaction in file, then all the transactions are processing correclty.
    SOA Version: SOA 11G (11.1.1.5).
    Example 1: below sample we got two transactions, 997 and 214. here 997 is the FIRST transaction in the file.
    in this case B2B is processing 997 correctly, and 214 is errored with below error message
    "B2B-51507 - A data segment with 'Mandatory' status is missing. A data segment with 'Mandatory' status is missing. An X12 syntax error occurred. An X12 syntax error occurred. An X12 syntax error occurred. A data segment with 'Mandatory' status is missing. A data segment with 'Mandatory' status is missing.
    ISA00* *00* *02*xxxx *01*1234555 *120516*1018*U*00401*000005822*0*P*:~*
    GSFA*xxxx*1234555*20120516*1018*5822*X*004010~*
    ST997*58220001~*
    AK1SM*7159~*
    AK9A*1*1*1~*
    SE000004*58220001~*
    GE1*5822~*
    IEA1*000005822~*
    ISA*00* *00* *02*xxxx *01*1234555 *120516*1018*U*00401*000005823*0*P*:~
    GS*QM*xxxx*1234555*20120516*1018*5823*X*004010~
    ST*214*58230001~
    B10*2313813*M1213131*xxxx~
    N1*SF*xxxxxx*ZZ*124~
    N4*xxxxxx*AR~
    LX*1~
    AT7*AF*NS***20120516*1017*LT~
    MS1*xxxxx*AR~
    L11*01*QN~
    AT8*G*L~
    SE*10*58230001~
    GE*1*5823~
    IEA*1*000005823~
    Example 2 : below sample we got two transactions, 997 and 214. here 997 is the LAST transaction in the file.
    in this case B2B is processing ALL TRANSACTIONS correctly
    ISA*00* *00* *02*xxxx *01*1234555 *120516*1018*U*00401*000005823*0*P*:~
    GS*QM*xxxx*1234555*20120516*1018*5823*X*004010~
    ST*214*58230001~
    B10*2313813*M1213131*xxxx~
    N1*SF*xxxxxx*ZZ*124~
    N4*xxxxxx*AR~
    LX*1~
    AT7*AF*NS***20120516*1017*LT~
    MS1*xxxxx*AR~
    L11*01*QN~
    AT8*G*L~
    SE*10*58230001~
    GE*1*5823~
    IEA*1*000005823~
    ISA00* *00* *02*xxxx *01*1234555 *120516*1018*U*00401*000005822*0*P*:~*
    GSFA*xxxx*1234555*20120516*1018*5822*X*004010~*
    ST997*58220001~*
    AK1SM*7159~*
    AK9A*1*1*1~*
    SE000004*58220001~*
    GE1*5822~*
    IEA1*000005822~*
    Thanks,
    Naveen

    Hi,
    My name is Phil DeLaine and I work for one of Oracle's Gold Partners, TechDemocracy.
    I saw your post about the B2B transaction errors you are experiencing. We have great experience with B2B and have solved very complex problems. (References available.)
    Would you like to use one of our B2B expert technical resources to solve this problem and deliver your project error free and fully functional?
    Please let me know if you would like to discuss what we can do for you. You can reach me anytime.
    Regards,
    Phil
    Phil DeLaine
    Sales Director - Northeast
    TechDemocracy
    (978) 758-3156 (Cell)
    [email protected]
    http://www.techdemocracy.com/
    Our Successes:
    1) We won the 2011 Oracle Titan Award for the Best Middleware Implementation. Our award winning solutions included SOA, IAM and BI.
    2) We have been awarded with the highly prestigious Oracle ACE Director status for outstanding industry achievement and track record.
    3) We sit on several Advisory Boards for Oracle Product Management (for Fusion Middleware Products).
    4) We are an Oracle Center of Excellence Partner for SOA and IAM.
    5) We are frequently invited to speak at a number of Oracle Customer Success forums such as Oracle's "OpenWorld".
    6) We have been rated by Inc. Magazine as one of the top 10 fastest growing companies for 3 consecutive years.
    7) We have won and successfully deliveried several projects at Fortune 100, 500 and 1,000 companies. (References Available)

  • Problem with multiple Toplink/JPA apps in same server

    Anyone have experence of running serveral Toplink/ EJB-3 Web apps in the same server (OC4J, alas)?
    We seem to get a problem with the second app failing to initialise toplink, with an entity not found message. Each app runs OK on it's own.

    Yes, they access the same datasource and most of the tables overlap.
    We're thinking it might help to have common entity classes and put them in a shared library, but I don't know if this is relevant (setting up shared libraries complicates testing and tends to snowball, I reckon we need about 15 jars all told).
    I''ve had some funnies on OC4J before which I think may be to do with it's use of ClassLoaders, for example I initially put persistence.xml in the libary jar with the data model, but for some reason I get the entity not found error that way. It only seems to work if it's in the classes folder.
    For the moment we're getting arround the problem with multiple OC4J instances in the server.

  • Scheduled Report - Bug with Multiple Selection LOV parameter

    Problem:
    I have a scheduled report with a parameter that has it's "Multiple Selection" checkbox checked. I schedule the report with multiple values selected. When I receive the report via email, the report ran as if I only selected one LOV value instead of multiple values.
    Facts:
    1) Enterprise version 10.1.3.2.1
    2) When you run the report manually with multiple values selected in the LOV, it runs great with the correct dataset.
    3) This scheduled report does not have a Data Template.
    James
    P.S. - I searched this forum for other treads on this issue. I didn't find any. Sorry if this is a duplicate.

    I have this same problem, too.
    When I select multiple parameters on the "View" screen for a given report, everything works fine.
    When I schedule it, however, only the last parameter I clicked on (regardless of whether a select a range or multiple individual values) is passed to the query. The other selections I make are ignored.
    What gives? Am I doing something wrong? Is this a bug? Is there a workaround?

  • Scheduling Agreement  with multiple line items of different plants

    Dear Gurus,
    In all plants, delivery of goods is done through multiple plants under one sales order.
    The system is given provision to create centralized sales order with multiple delivery plants but it fails at the time of execution.
    Hence sales order of same customer has to be prepared three times which leads to lack of control at central office.
    scheduling agreement is created and scheduled to deliver through multiple plants. While creating outbound delivery flashes error message as " Delivery split due to different shipping points"
    Please help me out.
    Regards,
    Anbu

    Hi Naveen,
    I guess you would like to change the delivery adress in the BBP_DOC_CHANGE_BADI.
    Here you can identify the delivery adress (partner function 00000027) line item by the field P_GUID. This P_GUID in the partner table (ET_PARTNER-P_GUID) consists the GUID of the SC line item (ET_ITEM-GUID).
    When you know the line item GUID, you can find the SC line item number in the item table (ET_ITEM-NUMBER_INT) and you can see which is the first, second... line item of the SC.
    Regards,
    Peter

  • How to Activate Windows 8.1 Enterprise with Windows 8 Enterprise MAK?

    I bumped into this problem when being assigned to deal with the activation of Windows 8.1 Enterprise.
    There are around 6 notebooks in my team, and they seldom connect to corporation network so are essentially isolated from our KMS server. Therefore we used to install Windows 8 Enterprise and activate these Windows 8's with an Enterprise MAK. However, These
    Windows 8 are going to be upgraded to Windows 8.1 Enterprise but my team is not given the MAK of Windows 8.1 Enterprise. Hence I am going to activate the Windows 8.1 Enterprise with my existing Windows 8 Enterprise MAK.
    To the best of my knowledge, there are 3 ways to upgrade Windows 8 to Windows 8.1:
    Install Windows 8.1 with a Windows 8.1 DVD.
    Install Windows 8 first, and upgrade to 8.1 through an Upgrade ISO.
    Install Windows 8 first, and upgrade to 8.1 through Windows Marketplace.
    I tried method 1 and 2 and found the Windows 8 MAK does not apply to Windows 8.1, in which slmgr -ipk would fail. Method 3 requires a full installation of all available Windows Updates first so I did not try it yet. I wonder if there is any possibility to
    activate the Windows 8.1 Enterprise with a Windows 8 Enterprise MAK. Any reply would be appreciated.
    By the way, my corporation do purchase the Software Assurance. I cannot get the 8.1 MAK due to management issue.

    Seems like it is illegal issue if management is against upgrade ;-)
    I do not think that this is a right way for Enterprise edition. New install is tyhe only option. There are some workaround on Internet, but these are not according to official upgrade path.
    Every multilicense program has its program administrator that could either help or can elevate problem to MS support services.
    M.

  • [repo_proxy 13] SessionFacade::openSessionLogon with user info has failed(Transport error: Communication failure.

    Post Author: LeeCUK
    CA Forum: Authentication
    I have installed Enterprise XIR2 onto a Windows 2003 server and all services are running.I have installed the client on another windows 2003 server and I can connect to the console via the web.
    Firstly desktop intel would not work and gave me the error below, however a new entry appeared in my server dropdown with servername (.Net Portal) and after selecting this Desktop intell worked.
    When I try to run designer I dont get the extra server in the dropdown nor does it connect when tryped manually and gives me the same error I was getting for desktop intel.
    Im using enterprise authentication
    Has anyone figured this out please?
    The error im getting is below[repo_proxy 13] SessionFacade::openSessionLogon with user info has failed(Transport error: Communication failure.(hr=#0x80042a01)

    Post Author: jsanzone
    CA Forum: Authentication
    LeeCUK:
    The &#91;repo_proxy 13&#93; error seems to be a catch-all for BO in that I've worked with this software (XI R2) for 1 1/2 years now and each time I've encountered &#91;repo_proxy 13&#93; it has been for a different reason, thus, you're going to have to apply troubleshooting checks all over the place until you find the problem. In my particular case I just resolved my &#91;repo_proxy 13&#93; error I've been working on this week, and here was my scenario.  Our server in the lab died due to a hard drive failure, so we cut our losses and installed a new & more powerful server.  When the rebuild was done I could not connect from my laptop to the repository via Designer (good old &#91;repo_proxy 13&#93; error).  After much angst, etc, etc I found out that the servers in the CMC (/businessobjects/enterprise115/admin/en/admin.cwrwere"&gt;http://<server>/businessobjects/enterprise115/admin/en/admin.cwrwere) were all down except for one (even though CCM showed all servers "up").  When I went to start the servers in the CMC I was prompted for an account, and no matter what account I tried it won't work.  So I went back to the CCM servers and stopped them all, then changed the default account it was using from LocalSystem to the administrator account, restarted all servers in CCM, went back to CMC and noted that all servers were now up as well.  Then I went back to my laptop and used Designer and was able to successfully log in.  Thus, the end of my story, however, it seems that many &#91;repo_proxy 13&#93; errors have different beginning and endings.  For instance, a year ago I had the same &#91;repo_proxy 13&#93; error and brought it to BO tech support.  They determined that I had to uninstall my client from my laptop, clean out the registry for any references to BO keys, and remove the c:\program files \Business Objects  folder, then reinstall, and sure enough it worked in that case, but not in this case when I tried it again.  By digging deeper I found out the root cause to my current problem, and voila, I'm in!
    Good luck!

  • Programming multiple smart cards with multiple smart card readers in a PC causes a PCSCException in a smart card that is in progress

    Hi,
    I develop a Java code using smartcardio API to program a smart card. My GUI allows to add at most 5 smart card readers that will wait for card present, then do authentication and program the smart card with an application, then wait for card removal. This is a separate thread running in a loop for each smart card reader added as programmer.
    The problem occurs when a certain smart card is in progress and I inserted another smart card to another smart card reader.  Both smart card reader halts and throw sun.security.smartcardio.PCSCException: Unknown error 0x8010002f.
    I also observed that every time there is an attempt to insert/remove a smart card in the smart card reader that is connected to the USB port would cause the programming in progress to be interrupted and throw the PCSCException.
    These are some exceptions I got during my testing:
    sun.security.smartcardio.PCSCException: Unknown error 0x8010002f
      at sun.security.smartcardio.PCSC.SCardTransmit(Native Method)
      at sun.security.smartcardio.ChannelImpl.doTransmit(ChannelImpl.java:171)
    java.lang.Exception: Loader Record Failed: 6E | 0 //Sometimes I got this return code SW1 0x6E SW2 0x00 which means an APDU with an invalid 'CLA' bytes was received. I had check the command before it was sent and it was correct.
    Help me understand this issue. I think the CardTerminal.isCardPresent(), CardTerminal.waitForCardPresent(0), and CardTerminal.waitForCardAbsent(0) cause this issue that CardChannel.transmit(apduCommand) is interrupted or the smart card insertion/removal causes the CardChannel.transmit(apduCommand) is interrupted.
    Regards,
    Knivez

    Hi,
    when you work with one smartcard reader only usually you address the slot -1 that means "the first found".
    But to deal with multiple readers you have to use slots of course since one reader will be slot 0, next reader will be slot 1 and so on...
    So a credential object will be identified on a system by a couple
    <slot,alias>
    After that, the way to address slots (I mean the syntax) depends on the classes you are using...
    Bye

  • I have a page with multiple quicktime players on it, and want to close all other players when any of the players is started.

    I have a page with multiple quicktime players on it, and want to close all other players when any of the players is started.
    <div id="mp3-player" style="display:none;height:15px !important;float:left;margin:0px 0 15px 0px; width:270px !important;">
                           <div style="height:15px !important;width:270px !important;">
                               <embed src='http://209.15.205.3/~cityval2/MP3/352681.mp3' width="270px" height="15px" AUTOPLAY=false CONTROLLER=true LOOP=false PLUGINSPAGE="http://www.apple.com/quicktime/" />
                            </div>
                        </div>

    One key point.
    1. Migration within  the same forest ; we can say operation is cut & paste (Source account wil be not present)
    2. Migration between the forest ; we can say operation is copy  & paste ( Source account will be present)
    Also find some ADMT cool stuffs.
    ADMT Series – 1. Preparing Active Directory
    ADMT Series – 2. Preparing the ADMT Machine
    ADMT Series – 3. SID History
    ADMT Series – 4. Password Export Server
    ADMT Series – 5. Machine Preparation
    ADMT Series – 6. Service Account Migration Wizard
    ADMT Series – 7. Group Account Migration Wizard
    ADMT Series – 8. User Account Migration Wizard
    ADMT Series – 9. Merging Users with a Different sAMAccountName
    ADMT Series – 10. Security Translation Wizard – Local Profiles
    ADMT Series – 11. Computer Migration Wizard
    Regards,
    Biswajit
    MCTS, MCP 2003,MCSA 2003, MCSA:M 2003, CCNA, Enterprise Admin, ITIL F 2011
    Blog:
      Script Gallary:
    LinkedIn:
    Note: Disclaimer: This posting is provided & with no warranties or guarantees and confers no rights..

Maybe you are looking for

  • Problems with SMTP port forwarding on ASA 5505

    Cannot telnet to port 25 to test for SMTP traffic.  Packet trace indicates that the packet is dropped by the implicit rule, but I have tried an access rule specifically for SMTP, and the trace appears to skip the rule and drop the packet when it hits

  • Outlook 2013 (included with Home and Business 2013) does not archive everything

    We are running on Exchange 2010 SP3. We have about 5 PCs with Office Home and Business 2013 (click-to-run version). We set up auto-archiving on all machines and set the options to apply on all folders. It's supposed to back up everything 24 months pr

  • How to remove sd card from iMac

    hi how to remove sd card from imac ,thanks

  • Port Forwarding for Filemaker Pro on Airport Extreme

    I really don't know what I'm doing - I'm trying to get my Instant Web for Filemaker to work - It was set up on my MacBook Pro and then I moved everything to this iMac and now it's not working. I do know that the port for FM Pro is 591. I have it set

  • Where does iTunes keep the "comments" field info?

    I've lost all the comments I recently entered for a particular CD and I need to figure out what file iTunes keeps that infomation in so I can get only that file out of a recent back up. This info is not in the file titled "iTunes Music Library.xml" i