JNI function name length exceeds linker support size?
hi,
JNI function names are Java_Package_classname_functionname. But i have a package+classname itself crossing 32 characters. i need to have more than one native function in the same class. so linker cannot distinguish these names. any workarounds?
thanx in advance
Hi,
I don't know of any way around JNI's name mangling rules, but pardon me for asking, the linker of what platform supports symbols with length <= 32 only these days?
Kind Regards,
Tobias
Similar Messages
-
Column name length exceeds maximum allowed
Hello,
I get this error when am trying to create a table. ERROR: Column name length exceeds maximum allowed length(30).
Is it able to extend this length to be more than 30 ? By the way I am using Oracle 11g
Regards,
Moussa El Tayeb
about.me/MoussaEltayebHello,
also Oracle has some limits. For more Information see the logical limits
http://docs.oracle.com/cd/E14072_01/server.112/e10820/limits.htm
regards
Peter -
Column Name Length of Tables In ODI
Hello Everyone,
I am facing with an unique issue in ODI. We are using ODI AIA for Integration, which has default XML exports of some JD Edwards tables.
These tables are automatically reversed and models are created using AIA, one such file is named Base.xml and is reversed as a Model named 'Base' in ODI. In this model there are various tables which are created on the basis of the contents of XML file. The column names are derived from XML Tags. Some XML tags are having length greater than 30. This does not create a problem in the model as such, but when using it as source in interface, the temporary tables that are created on-the-fly in a schema (Oracle) does not allow the length to be greater than 30 and hence the interface fails (error : Column name length exceeded), add to it, ODI suffixes column names with a Cnumber_. Since the XML file and tags are standard within the AIA, we cannot alter the length.
So is there a way to reduce the column name length of temporary tables which are created at runtime by ODI based on the source XML files ?
Thanks in advance,
NJIf you are using temp table that are created on the fly, you can not control the column length, so you have only one alternative just change the column name (less than 30) in model level.
Thanks -
Is there a way for my CVI project to reference the functions in the ActiveX without including the instrument .fp in the project?
Thanks much.
I'm confused on how CVI uses ActiveX components and hope someone can help.
I'm using an ActiveX driver from an instrument manufacturer and I use the .TLB to generate a .fp, .c, and .h file. If I register the .dll and load the .fp in my project, all is well. Unfortunately in my application the functions to control this instrument are in another DLL whose .lib I include in my CVI projec
t. Running the CVI project this way gives me "The procedure entrypoint ssSr192x__ssSr192drvssSrReset could no be located in the dynamic link library ssSR192x.dll" because the instrument function names aren't in the export table in the instrument DLL. Non-ActiveX DLLs have the export tables so everything works for them.
Program structure with non-ActiveX DLLs:
CVI project (.exe with common.lib in project list)
|
V
Common DLL (MeasDMM() with hp1234.lib in project list)
|
V
Instrument DLL (hp1234_measure())
Since I get a .c and .h file from the .TLB, I've tried recompiling the DLL (.dll and .lib produced) and the functions seem to work, but I get "Class not registered" errors unless I play games with the registry so I'm obviously violating numerous Microsoft rules!
Is there a way for my CVI project to reference the functions in the ActiveX without including the instrument .fp in the project? Thanks much.
Jeff Fish
Advisory Test Engineer
StorageTekHello Jeff,
Where were your getting the .lib file for the ActiveX DLL? Did you use the "hp1234"
ActiveX driver generated by the "Create ActiveX Automation Controller" CVI Tool to build a static library? If you open an include file and choose Options >> Generate DLL..., it will generate source code or a static import library to load the specified DLL and load functions specified in the include file (this only works if the functions are exported from a DLL). However, in the case of our ActiveX Automation Controllers, ActiveX calls are used to access a DLL. This means that you do not need an import library. You should be able to open the "hp1234" source file and click Options >> Create Object File. Simply #include "hp1234.h" and add "hp1234.obj" to your Common DLL project;
the .fp file is not necessary. If this does not answer your questions or if you experience further difficulty, please post further details on what you are doing and the errors that are being encountered ("play games with the registry" and "recompiling 'the' DLL" are a bit vague in this case).
Jeremiah
Applications Engineer
National Instruments
http://www.ni.com/ask -
Bcp doesnt throw an error when the data length exceeds size of the column
Hi,
We are using bcp in SQL 2008 R2 to import the data from flat file. When the data length exceeds the size of the column, it doesn't throw any error instead it has ignored the row.
Please suggest me how to truncate and load the data into table.
Thanks,
PashaHi Pasha,
According to your description, you want to import the data from flat file to SQL Server table with truncated data in SQL Server 2008 R2. To achieve your requirement, we can use Import and Export wizard. For more details, please refer to the following steps:
Launch SSMS by clicking SQL Server Management Studio from the Microsoft SQL Server program group.
Right click on the destination database in the Object Explorer, select Tasks, then Import Data from the context menu to launch the Import Wizard.
Choose Flat File Source as Data Source, then browser to the flat file.
Choose SQL Server Native Client 10.0 as Destination, then select the destination database.
Click Edit Mappings button to change column size or other properties.
Finish the processing.
For the example about how to use Import and Export wizard, please refer to the blog below:
http://www.mssqltips.com/sqlservertutorial/203/simple-way-to-import-data-into-sql-server/
Thanks,
Katherine Xiong
Katherine Xiong
TechNet Community Support -
Link options to hide function names
We are looking for a better way to keep function names hidden in our executable. Strip is still leaving names we'd like to remove and using -Beliminate seems to remove everything including environment variable names we are passing from the shell, breaking Tcl scripts we use in conjunction with the app. Is there a way to tell the linker to strip functions and allow exported vars?
Thanks!You can have fewer global symbols in the executable by restricting their scope. Refer to the C++ Users Guide, chapter 4, under Linker Scoping. You can get the same effect with a linker map file, but the source code extensions are usually more convenient.
-
I have a File to IDOC Message Mapping Scenario:
Source Field Targefield
Communiication Address-(Email ID) E1EDK2 - TDLINE
Source Field length: 1/80 target Field length: Char\70
Mapping Condition:
Note: TDFORMAT = ‘=’ (Long Line), may need to create 2 TDLINE fields depending on length of text
So give the Solution for handling text Length exceed than target field lenght Using TDLNE and TDFORMAT......
Guide me and give Suggestions to achive this.Hi ,
Below is the generic sol for your problem .Graphical mappings wont workout for your problem while using sub string .
Input -->Input string
Length -->length of TDLINE
MESSAGE_V1,V2,V3,V4....depends on how many TDLINES you expect .Here I have taken 4 .
public void SplitbyLength(String[] Input, String[] Length, ResultList MESSAGE_V1, ResultList MESSAGE_V2, ResultList MESSAGE_V3, ResultList MESSAGE_V4, Container container) throws StreamTransformationException{
int lengthVal = Integer.parseInt(Length[0]);
int InpLenVal ;
for(int i=0;i<Input.length;i++)
InpLenVal =Input[i].length() ;
if (InpLenVal<=lengthVal)
MESSAGE_V1.addValue(Input[i].substring(0));
MESSAGE_V2.addValue(ResultList.SUPPRESS);
MESSAGE_V3.addValue(ResultList.SUPPRESS);
MESSAGE_V4.addValue(ResultList.SUPPRESS);
else if ((InpLenVal>lengthVal) && (InpLenVal <= (lengthVal*2)))
MESSAGE_V1.addValue(Input[i].substring(0,lengthVal));
MESSAGE_V2.addValue(Input[i].substring(lengthVal,InpLenVal));
MESSAGE_V3.addValue(ResultList.SUPPRESS);
MESSAGE_V4.addValue(ResultList.SUPPRESS);
else if ((InpLenVal>(lengthVal*2)) && (InpLenVal <= (lengthVal*3)))
MESSAGE_V1.addValue(Input[i].substring(0,lengthVal));
MESSAGE_V2.addValue(Input[i].substring(lengthVal,(lengthVal*2)));
MESSAGE_V3.addValue(Input[i].substring((lengthVal*2),InpLenVal));
MESSAGE_V4.addValue(ResultList.SUPPRESS);
else if (Input[i].length()>(lengthVal*3) && (InpLenVal <= (lengthVal*4)))
MESSAGE_V1.addValue(Input[i].substring(0,lengthVal));
MESSAGE_V2.addValue(Input[i].substring(lengthVal,(lengthVal*2)));
MESSAGE_V3.addValue(Input[i].substring((lengthVal*2),(lengthVal*3)));
MESSAGE_V4.addValue(Input[i].substring((lengthVal*3),InpLenVal));
else if (Input[i].length()>(lengthVal*4) )
MESSAGE_V1.addValue(Input[i].substring(0,lengthVal));
MESSAGE_V2.addValue(Input[i].substring(lengthVal,(lengthVal*2)));
MESSAGE_V3.addValue(Input[i].substring((lengthVal*2),(lengthVal*3)));
MESSAGE_V4.addValue(Input[i].substring((lengthVal*3),(lengthVal*4)));
Regards
Venkat -
I am trying to deploy an RDL file (5MB) to SQL Azure Reporting server in South Central US using the deploy function in SQL Server Data Tools but facing the following error during deployment to Azure Reporting server.
"There was an exception running the extensions specified in the config file. ---> Maximum request length exceeded."
Is there any limit on the size of RDL files which can be deployed to Azure Reporting server? I have seen some online posts which talk about increasing the maxRequestLength in httpruntime of web.config in Reporting server. But in case of Azure Reporting server
how can be make modification to this configuration?
I have tried to upload it directly to SQL Azure Reporting server from the Management Portal --> Upload Report function which still resulted in error.
Thanks & Regards, DeepThanks for your question. Unfortunately we are in the process of deprecating SQL Reporting services. Full details are available at http://msdn.microsoft.com/en-us/library/gg430130.aspx
Thanks Guy -
Exceeds data buffer size discarding this snmp request
Morning
Cisco Prime LMS 4.2.3 is sending SNMP request too big for asa interface buffer.
LMS is running on Windows server
incoming SNMP request (528 bytes) from IP address x.x.x.x Port 50592 Interface "inside" exceeds data buffer size, discarding this SNMP request.
212005: incoming SNMP request (%d bytes) from %s exceeds data buffer size, discarding this SNMP request.
It is very much like this error
Error Message %PIX-3-212005: incoming SNMP request (number bytes) on interface
interface_name exceeds data buffer size, discarding this SNMP request.
Explanation This is an SNMP message. This message reports that the length of the incoming SNMP request, destined for the firewall, exceeds the size of the internal data buffer (512 bytes) used for storing the request during internal processing; therefore, the firewall is unable to process this request. This does not affect the SNMP traffic passing through the firewall via any interface.
Recommended Action Have the SNMP management station resend the request with a shorter length, for example, instead of querying multiple MIB variables in one request, try querying only one MIB variable in a request. This may involve modifying the configuration of the SNMP manager software.
how do I change the SNMP request size in LMS?
I can only find the following that might be an option
http://blogs.technet.com/b/mihai/archive/2012/05/14/reducing-the-maximum-number-of-oids-queried-in-a-single-batch-in-om-2012.aspx
any thoughts on the matter would be appreciated
just using default settings with snmpv3Bug in lms 4.2.3
CSCtj88629 Bug Details
SNMP packet size requests from LMS is too large
Symptom:
LMS sends more than 512 SNMP requests to the FWSM, so it rejects the requests.
Conditions:
This occurs with FWSM and ASA's.
Workaround:
None.
http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCtj88629 -
Maximum request length exceeded
I'm trying to upload a file to mobile services .NET backend, however I'm getting the error "Maximum request length exceeded". I tried increasing the limit in web.config file, but it only worked on the local version and still throws the error when
published to Azure.
As far as I understand the mobile services is ignoring the web.config file. So is there any other way to increase the upload limit?good news.. found a fix for this.
it's actually the same fix for file uploads that exceed the default 4mb set by IIS. however, the change needs to made to the report manager web.config file and not the report server web.config file. that's why it didn't work for me the first time.
here is an article that talks about it http://support.softartisans.com/kbview_825.aspx
if you have kept the default installation directory, the file you edit is:
C:\Program Files\Microsoft SQL Server\MSSQL.3\Reporting Services\ReportManager\Web.config
Just add the maxRequestLength property here and set a size appropriate to you. Not to large to discourage DoS attacks.
The example below is 10mb
<httpRuntime executionTimeout="9000" maxRequestLength="10240"/>
hope it helps. -
I'm trying to determine if I can have names greater than 15 characters in both Windows server 2012 and AD. To be clear, we are not concerned with backwards compatibility with anything older than Windows 7/2008 R2, so NetBIOS is not a factor that I know of.
I'm just wondering if using log server names will cause issues in AD, or from a stability/supportability standpoint. Please advise.The maximum length of the host name and of the fully qualified domain name (FQDN) is 63 bytes per label and 255 bytes per FQDN. Note Windows does not permit computer names that exceed 15 characters, and
you cannot specify a DNS host name that differs from the NETBIOS host name. -
Domain name does not link to index page.
Having a lot of difficulty publishing to FTP, have researched many forums and unable to find answers. Whether I publish to FTP via iWeb or Cyberduck, my domain name danbaileymusic.com shows a 403 Forbidden Error. However if i type in danbaileymusic.com/index or /music, ect it loads. The whole site functions fine, but the domain name does not link to the index page.
In Cyberduck all permissions have been turned on. Also I noticed that when publishing to a local folder, iWeb creates a folder "danbailey" and an index.html. This index page does not work in Cyberduck, however the index page that is WITHIN the folder "danbailey" does work, but it doesn't link to the domain name.
Please help! I've been working on this for weeks and cannot figure out why the domain name is not working!It only creates the page names with first letter capitalized (as in Index not index) I have tried changing it from the sidebar and from the Page Name in the Inspector -- typing "index" comes back as "Index" It's easy enough to change the "I" to an" i" at the file level (which did fix the problem) but doing this also breaks all the links I have to "Index.html" Fixing this on the creation side would be ideal. Thoughts?
I am using iWeb '09 v.3.0.1 if that makes a difference -
How to get the function name/ID of the current page
HI,
I searched the forum and google, but it is not clear on how to get the function name of the current page.
I have 4 functions in my self service A ,B,C,D (seeded page links ) they all have to go to a page called hhhPG. Based on which function user is clicks I have to show the data in hhhPG.
so my question is how to get the function name ? I mean I need to know if user click on link A , B, C or D link and came to this page.
I found below in one forum and also there is getfunctionID in pageContext , but I do not know what to pass to getfunctionid("???") to get value.
FunctionSecurity funcSecurity = pageContext.getFunctionSecurity();
Or is there a better way of know where user is coming from ? like geturl....
Please help, I need this ASAP.
Thank you.Use below to find out how the user came into the page
FunctionSecurity funcSecurity = pageContext.getFunctionSecurity();
boolean isFunc1 = funcSecurity.testFunction(funcSecurity.getFunction("YOUR_FUNCTION_SHORT_NAME1"));
boolean isFunc2 = funcSecurity.testFunction(funcSecurity.getFunction("YOUR_FUNCTION_SHORT_NAME2"));
boolean isFunc3 = funcSecurity.testFunction(funcSecurity.getFunction("YOUR_FUNCTION_SHORT_NAME3"));
boolean isFunc4 = funcSecurity.testFunction(funcSecurity.getFunction("YOUR_FUNCTION_SHORT_NAME4"));
So one of them will be true based on the function the user came in.
Write your logic based on these flags.
Regards,
Peddi. -
Newbie ERROR- URL Encoded SQL Length exceeds allowed 32K limit
My SQL Query worked fine yesterday.( I'm still in developing mode)
I made a copy of it and put it into a text file.( Just to be sure I had it.)
Today When I tried to run it in APEX , I get error
URL Encoded SQL Length exceeds 32K limit.
Is there any way to tell how the size of my query ( for example 33K)
is using?
TIA
Steve42I had to put out some other fires for the last few days.
I'm trying to use it in SQL worksheet.
That is my entire error message. It does NOT have an Error #.
Product Build: 3.0.0.00.20
TIA,
Steve42 -
Module Function Name Resolution - Issues with DefaultCommandPrefix
Just getting started on module development, running PS4, and I've run into an... inconsistency... that I'm trying to understand. I've got two test functions, Get-Something and Set-Something in a script module. In my manifest file I specify a DefaultCommandPrefix
of 'Test'.
My issue is the function name resolution doesn't result in an executable result if you leave PowerShell up to it's own process.
To begin with I closed all sessions and deleted all files in the CommandAnalysis directory. After starting a session I waited for the CommandAnalysis cache to populate. Then I ran a series of test commands to illustrate how, most of the time, the function
name PowerShell registers with tab completion can't be executed because it lacks the 'Test' prefix. Even worse, much of the time tab completion won't recognize the correct (i.e., with prefix) name of the function and honor tab completion for it.
Having just learned of the CommandAnalysis cache I assumed I would see it change as PowerShell 'learned' more about the module because the name resolves differently over time. I've included three files at the end of this post, the module code (ModuleTest.psm1),
the manifest (ModuleTest.psd1) and the capture of output to the PowerShell session (ModuleTest.txt). I've tried to include the times I used <tab> and <ret> for tab completion and execution as well as (comments in parenthesis for things I did like
starting a new session and checking the CommandAnalysis cache for changes).
An example is, when first starting a session typing 'get-som<tab>' will resolve to 'Get-Something' (prefix 'Test' missing) and typing 'get-test<tab>' won't resolve to 'Get-TestSomething'. Try to execute the 'Get-Something' from tab completion
and you'll get the 'name not recognized, blah, blah'.
Now if you type 'get-som<tab>' PowerShell will resolve to 'ModuleTest\Get-Something' - looks promising... but no. Try to execute the 'ModuleTest\Get-Something' from tab completion and you'll still get the 'name not recognized, blah, blah'.
Even though the same key strokes resolved differently there were no changes made to the CommandAnalysis cache so I'm lost on why it produces two different (though equally useless) results.
Manually importing the module and sometimes running Get-Command -Module ModuleTest will make tab completion of the function names behave correctly. Is this a known issue with using DefaultCommandPrefix in script modules or is there something I need to include
in the manifest to enforce strict name recognition (including the prefix)?
<ModuleTest.psm1>
function Get-Something
Write-Host "Get-Something Executed"
function Set-Something
Write-Host "Set-Something Executed"
<ModuleTest.psd1>
# Script module or binary module file associated with this manifest
ModuleToProcess = 'ModuleTest.psm1'
# Version number of this module.
ModuleVersion = '1.0.0.0'
# ID used to uniquely identify this module
GUID = '241877ff-64be-40c8-a603-8d5acf7a48d8'
# Author of this module
Author = 'wb3'
# Company or vendor of this module
CompanyName = ''
# Copyright statement for this module
Copyright = '(c) 2015. All rights reserved.'
# Description of the functionality provided by this module
Description = 'Module description'
# Minimum version of the Windows PowerShell engine required by this module
PowerShellVersion = '2.0'
# Name of the Windows PowerShell host required by this module
PowerShellHostName = ''
# Minimum version of the Windows PowerShell host required by this module
PowerShellHostVersion = ''
# Minimum version of the .NET Framework required by this module
DotNetFrameworkVersion = '2.0'
# Minimum version of the common language runtime (CLR) required by this module
CLRVersion = '2.0.50727'
# Processor architecture (None, X86, Amd64, IA64) required by this module
ProcessorArchitecture = 'None'
# Modules that must be imported into the global environment prior to importing
# this module
RequiredModules = @()
# Assemblies that must be loaded prior to importing this module
RequiredAssemblies = @()
# Script files (.ps1) that are run in the caller's environment prior to
# importing this module
ScriptsToProcess = @()
# Type files (.ps1xml) to be loaded when importing this module
TypesToProcess = @()
# Format files (.ps1xml) to be loaded when importing this module
FormatsToProcess = @()
# Modules to import as nested modules of the module specified in
# ModuleToProcess
NestedModules = @()
# Default command prefix
DefaultCommandPrefix = 'Test'
# Functions to export from this module
FunctionsToExport = '*'
# Cmdlets to export from this module
CmdletsToExport = '*'
# Variables to export from this module
VariablesToExport = '*'
# Aliases to export from this module
AliasesToExport = '*'
# List of all modules packaged with this module
ModuleList = @()
# List of all files packaged with this module
FileList = @()
# Private data to pass to the module specified in ModuleToProcess
PrivateData = ''
<ModuleTest.output>
PS C:\Scripts\PowerShell> Get-ChildItem -Path 'C:\Program Files\WindowsPowerShell\Modules' -Recurse<ret>
Directory: C:\Program Files\WindowsPowerShell\Modules
Mode LastWriteTime Length Name
d---- 3/5/2015 9:06 AM ModuleTest
Directory: C:\Program Files\WindowsPowerShell\Modules\ModuleTest
Mode LastWriteTime Length Name
-a--- 3/5/2015 8:50 AM 2907 ModuleTest.psd1
-a--- 3/5/2015 9:01 AM 140 ModuleTest.psm1
PS C:\Scripts\PowerShell> Get-Module -ListAvailable<ret>
Directory: C:\Program Files\WindowsPowerShell\Modules
ModuleType Version Name ExportedCommands
Script 1.0.0.0 ModuleTest {Get-Something, Set-Something}
PS C:\Scripts\PowerShell> get-som<tab>
PS C:\Scripts\PowerShell> Get-Something<ret>
Get-Something : The term 'Get-Something' is not recognized as the name of a cmdlet, function, script file, or operable
program. Check the spelling of the name, or if a path was included, verify that the path is correct and try again.
At line:1 char:1
+ Get-Something
+ ~~~~~~~~~~~~~
+ CategoryInfo : ObjectNotFound: (Get-Something:String) [], CommandNotFoundException
+ FullyQualifiedErrorId : CommandNotFoundException
(No change in CommandAnalysis cache)
PS C:\Scripts\PowerShell> get-som<tab>
PS C:\Scripts\PowerShell> ModuleTest\Get-Something<ret>
ModuleTest\Get-Something : The term 'ModuleTest\Get-Something' is not recognized as the name of a cmdlet, function,
script file, or operable program. Check the spelling of the name, or if a path was included, verify that the path is
correct and try again.
At line:1 char:1
+ ModuleTest\Get-Something
+ ~~~~~~~~~~~~~~~~~~~~~~~~
+ CategoryInfo : ObjectNotFound: (ModuleTest\Get-Something:String) [], CommandNotFoundException
+ FullyQualifiedErrorId : CommandNotFoundException
(No change in CommandAnalysis cache)
PS C:\Scripts\PowerShell> get-tes<tab>
PS C:\Scripts\PowerShell> Get-TestSomething<ret>
Get-Something Executed
(New Session)
(No change in CommandAnalysis cache)
PS C:\Scripts\PowerShell> get-tes<tab><ret>
get-tes : The term 'get-tes' is not recognized as the name of a cmdlet, function, script file, or operable program.
Check the spelling of the name, or if a path was included, verify that the path is correct and try again.
At line:1 char:1
+ get-tes
+ ~~~~~~~
+ CategoryInfo : ObjectNotFound: (get-tes:String) [], CommandNotFoundException
+ FullyQualifiedErrorId : CommandNotFoundException
PS C:\Scripts\PowerShell> Import-Module ModuleTest<ret>
(No change in CommandAnalysis cache)
PS C:\Scripts\PowerShell> get-tes<tab><ret>
PS C:\Scripts\PowerShell> Get-TestSomething
Get-Something Executed
(New Session)
(No change in CommandAnalysis cache)
PS C:\Scripts\PowerShell> get-tes<tab><ret>
get-tes : The term 'get-tes' is not recognized as the name of a cmdlet, function, script file, or operable program.
Check the spelling of the name, or if a path was included, verify that the path is correct and try again.
At line:1 char:1
+ get-tes
+ ~~~~~~~
+ CategoryInfo : ObjectNotFound: (get-tes:String) [], CommandNotFoundException
+ FullyQualifiedErrorId : CommandNotFoundException
PS C:\Scripts\PowerShell> Get-Command -Module ModuleTest<ret>
CommandType Name
ModuleName
Function Get-TestSomething
ModuleTest
Function Set-TestSomething
ModuleTest
(No change in CommandAnalysis cache)
PS C:\Scripts\PowerShell> get-tes<tab>
PS C:\Scripts\PowerShell> Get-TestSomething<ret>
Get-Something Executed
PS C:\Scripts\PowerShell> moduletest\get<tab><ret>
PS C:\Scripts\PowerShell> Get-TestSomething<ret>
Get-Something Executed
William Busby, PMPHi William,
yes, that's something you'll either have to do the hard way or live with admin confusion.
If you're using Sapien's PowerShell Studio as an Editor (hint: Usually a great idea), you can very easily rename a function, even in a multi-file module project, by rightcklicking on the function-name and selecting "rename".
Alternatively you can do a bulk rename with Powershell:
Get all functions in your module (Load it and check exportedcommands)
loop over each function-name
calculate new name
search your entire project for all references and replace them.
Let me see ...
function Rename-ModulePrefix
[CmdletBinding()]
Param (
[Parameter(Position = 0, Mandatory = $true)]
[string]
$ModuleName,
[Parameter(Position = 1, Mandatory = $true)]
[string]
$OldPrefix,
[Parameter(Position = 2, Mandatory = $true)]
[string]
$NewPrefix,
[Parameter(Position = 3)]
[string]
$Path
# Catch all typos
Import-Module $ModuleName -ErrorAction 'Stop'
# Get root path if not manually passed
if (-not $PSBoundParameters["Path"])
$Path = (Get-Module $ModuleName).Path
# Get module files
$Files = Get-ChildItem -Path $path -Recurse -Include "*.ps1", "*.psm1", "*.psd1"
# Iterate over each file
foreach ($file in $Files)
# Null variable in case you get an empty file somewhere and run this from Win 7
$data = $null
# Get Content of file
$data = Get-Content $file
# Replace strings
foreach ($c in (Get-Module $ModuleName).ExportedCommands)
$newName = $c.Name -replace $OldPrefix, $NewPrefix
$data = $data | ForEach-Object { $_ -replace $c.Name, $newName }
# Write back to file
$data | Set-Content $file
While I didn't proof it, in theory this should do it (Make a backup before running it :) ).
Cheers,
Fred
There's no place like 127.0.0.1
Maybe you are looking for
-
How can we copy FSV from one system to another system
Hi Gurus, I was created FSV in sand box, i want to creat same in Dev system also like this i have to create 5 fsv s in dev system which already created in sandbox is there any way to copy from sandbox to Devsystem Kindly guide me on this Thanks in
-
old pc from which i synced my ipod is broken. cannot perform a direct file transfer. need to import music to new pc from ipod, but neither itunes nor the computer itself will import the music files. i do not have all of the old cds, and it would be a
-
Importing NT User information into Portal
We are using Portal in an NT environment, and we have been able to get through the necessary single sign on issues. Now, we need to pull our NT user information into Portal's user database, including all the groupings we already have set up so that w
-
IPod shows white screen (issue?)
My 8GB Ipod touch 4th gen has locked up. Shows me a solid white screen and will not show anything. Is there a way to reset it? I tried to hold the main home button and the button on top and no luck HELP PLEASE>.....
-
SQL extraction from network trace?
Anyone know of a way to easily extract SQL statements from a ".cap" file created from a protocol analyzer like "snoop" or MS Network Monitor? It seems too useful for someone not to have created such a utility. I can use something like Ethereal to bro