Neo4 does not POST (Power cuts + 3 second Power LED Blinking)

Hi,
This is my first build and I have already been plagued with 2 problems.  First, I finished the build and ran for one night and then the PSU went bad and needed to be replaced (replaced with same model).  Now, after running fine for about two weeks, the system shutdown over night and won't restart.  No activity should have been happening overnight.   When I try to start the system, the fans and everything start for about one second and then stop.  The power LED begins to blink every 3 seconds and no power is given to the system.  The D-bracket does not have any lights showing, they go out after the first second of running.  Here is what I have tried so far:
1.  Tested power supply on second system and it worked fine.
2.  Removed the motherboard from the case and set it on the static bag it came in.  Then with only the video (with it's power) and the two MB power cables connected, I tried to boot the system.  The same problem occured, power off after 1 second and LED blinks.
3.  Bought a new PSU (Mad-Dog 500W which has +12V/30A) and still the same problem.
4.  Removed each RAM module and tried with just one stick, still the same problem. 
So I think I the only things left are MOBO and CPU...  I would think if it was the CPU, I would get a signal from the D-Bracket.  Any help? 
Thanks in advance!

Quote from: Deathstalker on 12-April-05, 00:14:59
I would try removing the Power Cord from the Power Supply and the Battery from the mobo. Leave them out a good 15 to 20 minutes before putting them back.
If that does not work, try a different brand of RAM for testing purposes.
Deathstalker,
Thanks for the suggestions.  I tried removing the battery and power for 15 minutes and replacing, but no luck, same problem.  This system was working for two weeks with the PQI RAM modules. Can this compatability change all of a sudden while running and just power down the system?

Similar Messages

  • WRT54GP2 not working - Power LED blinking fast.

    My WRT54gp2 has been working without issues for 2 years. All of a sudden from yesterday, the power LED is blinking fast. I am not able to connect to the web interface. My computer says limited or no connectivity. The internet and WAN LED are steadily lit. Has anyone faced this issue ? Is my router brick now ?

    As the power light on the router is blinking..It means that the firmware of router is corrupted..Check this link to unbrick the router.

  • HP MS218 Not Booting - Does not POST - Cannot reach BIOS

    Hello,
    I have an MS218 (product number: BR372AA #ABA) that I have been having issues with. It used to work fine (ran on WinXP), but currently will not even boot properly at all. No software or hardware changes were made to cause this problem to begin occurring, it simply just started happening one day when I went to turn the computer back on. The issue that I am currently experiencing is as follows:
    - Power stays on, but nothing is ever displayed on the screen
    - Does not post, cannot reach BIOS
    - Acts almost as if it is resetting itself constantly, the fan in the back will start to spin for a second or two, then stop, then start again, and repeat indefinitely until I unplug the power adapter.
    I initially figured it was a hardware issue, likely the motherboard, and began to troubleshoot the problem. As I removed non-vital components, the problem would persist. For instance, it happens regardless of external things (keyboard, mouse, etc.) being plugged in, or regardless of the hard drive or optical drive being plugged in. It still appears to happen in the absense of memory, however, I will instead hear beep codes (likely telling me that I don't have any RAM in). Ultimately, I decided to order a replacement motherboard, which recently arrived. Upon replacing the motherboard, the exact same problems happen, which leads me to believe that the motherboard was somehow not the culprit. I have also tried multiple power adapters to no avail, as well as resetting the CMOS battery without any luck. I'm really at a loss for what to do from here, and am currently sitting on hold with HP tech support.
    Any advice is welcome. Thanks in advance for your time and assistance.

    Hello Jaycera,
    There are two more components that we haven't replaced or look at and I would approach them in the order listed.
    1. Power supply
    2. Processor
    It sounds like it's a power issue the computer is getting enough power to start booting up and then losing it. Thus anytime I hear a power issue the first thing I think of is a power supply issue.
    The other thing is it could be the processor. The computer starts booting, makes a call to the processor, fails, boots down, starts booting up, makes a call to the processor and here we are in a vicious cycle.
    It could just be the processor needing reseated. Take it out, put it back in and make sure it's in properly and no pins are bent, or the processor could be bad.
    If I have helped you in any way click the Kudos button to say Thanks.
    The community works together, click Accept as Solution on the post that solves your issue for other members of the community to benefit from the solution.
    - Friendship is magical.

  • "Date/Time To Seconds" Function does not respond to "fractiona​l second" input

    The "Date/Time To Seconds" function (contained in the Fuctions\Programming\Timing - Palette) does not respond to the "fractional second" input (see attached example).
    Reimar Spohr
    Attachments:
    Date-Time To Seconds VI Example.png ‏18 KB

    Instead of creating a new post, you should have posted this in the original thread, where people already tried to help you. Please keep the discussion in that thread.

  • Ask for help :( "%ILPOWER-3-CONTROLLER_PORT_ERR: Controller port error, Interface Gi1/0/17: Power given, but Power Controller does not report Power Good"

    This question is used a translator.... 
    Current conditions 
     - SW1 ----- Power injector ------ AP(cisco is not another model)
     - Port, AP, Power injector, Switch <-> Injector UTP cable  Problems occur even after replacement
     - Power injector <->AP UTP canle No exchange
     - Poe was OFF the function. This is because it is being used for Power Injector. -> Do not generate failure logs
     - But even if another AP is turned ON POE function, no error messages.
    SW1#show logging (5 mins cycle persists)
    May  4 10:37:32.527: %ILPOWER-3-CONTROLLER_PORT_ERR: Controller port error, Interface Gi1/0/17: Power given, but Power Controller does not report Power Good
    May  4 10:37:42.556: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to down
    May  4 10:37:43.562: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to down
    May  4 10:37:50.032: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to up
    May  4 10:37:52.046: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/17, changed state to up
    May  4 10:38:03.238: %ILPOWER-7-DETECT: Interface Gi1/0/17: Power Device detected: IEEE PD
    SW1#show cable-diagnostics tdr interface gi 1/0/17    <----- Issues AP         
    TDR test last run on: May 04 10:49:14
    Interface Speed Local pair Pair length        Remote pair Pair status
    Gi1/0/17  1000M Pair A     84   +/- 10 meters Pair B      Normal              
                                Pair B     84   +/- 10 meters Pair A      Normal              
                                Pair C     84   +/- 10 meters Pair D      Normal              
                                Pair D     84   +/- 10 meters Pair C      Normal              
    SW1#show cable-diagnostics tdr interface gigabitEthernet 1/0/18    <--------- Normal AP
    TDR test last run on: May 04 11:01:04
    Interface Speed Local pair Pair length        Remote pair Pair status
    Gi1/0/18  1000M Pair A     92   +/- 10 meters Pair B      Normal              
                               Pair B     92   +/- 10 meters Pair A      Normal              
                               Pair C     92   +/- 10 meters Pair D      Normal              
                               Pair D     92   +/- 10 meters Pair C      Normal  
    SW1#show cable-diagnostics tdr interface gigabitEthernet 1/0/1   <--------- Normal AP
    TDR test last run on: May 04 11:01:56
    Interface Speed Local pair Pair length        Remote pair Pair status
    Gi1/0/1   1000M Pair A     79   +/- 10 meters Pair B      Normal              
                               Pair B     79   +/- 10 meters Pair A      Normal              
                               Pair C     79   +/- 10 meters Pair D      Normal              
                               Pair D     79   +/- 10 meters Pair C      Normal              
    SW1#show power inline    <-------- (Check every 5 seconds)
    Module   Available     Used     Remaining
                   (Watts)     (Watts)    (Watts) 
    1              370.0      200.2       169.8
    Interface Admin  Oper       Power     Device                           Class   Max
                                                (Watts)                            
    SW1#show power inline | in 17
    Gi1/0/17  auto     off        0.0                 n/a                               n/a   30.0 
    SW1#show power inline | in 17
    Gi1/0/17  auto     on         15.4             Ieee PD                         0     30.0 
    SW1#show power inline | in 17
    Gi1/0/17  auto     on         15.4             Xirrus XR2426, 1.0G     0     30.0 
    SW1#show power inline | in 17
    Gi1/0/17  auto     faulty     0.0              n/a                                 n/a   30.0 
    SW1#show power inline | in 17
    Gi1/0/17  auto     off        0.0                n/a                                  n/a   30.0

    Plug the Xirrus AP directly to the switch port and see if the logs go away or not.

  • System does not post after Bios Flash

    After using Live Update to flash my Bios to the new version, the computer does not POST. The Bios Flash was successful - it rebooted and started normally. When I tried to restart it the normal way, it will not boot. The fans run when the "power on" button is pressed but nothing more. I cleared the CMOS using the jumpers but the problem was not solved. Can any one help?
    Can some good Samaritan give me a step by step method to resolve this problem?

    I followed the link you provided and managed to resolved it:
    1) Removed one memory stick and floppy;
    2) Cleared CMOS and rebooted successfully;
    3) Inserted floppy and reverted to the previous BIOS;
    4) Inserted the other memory stick and brought system back to full power again.
    Thank you very much for your assistance. I am sure MSI is aware of the problem and will take steps to rectify it ASAP

  • K9N2 plat does not post

     I have been having multiple issues with my system and I later determined that it was the power supply. I replaced the PSU and I also got a new case in the process. I installed everything in the new case including the PSU. I turned it on to test the system before I put all the USB stuff and peripherals into the mobo and it works good, everything is normal, but once I hooked all my peripherals like my keyboard, mouse, monitor it completely stopped posting the little LEDs are all red and the speaker does not make a beep. I unhooked it all and the problem still persisted. Then i took out my GPU and tried to turn it on and still and the LEDs are red I took out the mobo out of the case took all but one stick of ram off the mobo and hooked it up to the PSU and still it does not post,  and the LEDs are still red. Can someone tell me how to fix this problem or do i need to get a new mobo all together?   

    Read the posting guide as Stu says and post your system specs.
    To start with clear the CMOS: >>Clear CMOS Guide<<

  • Work order to cost center settlement does not post to GL module (FI)

    Dear Expert,
    I find the Maintenance Work order to cost center settlement does not post to GL module (FI)?Also, the settlement cost element is primary element define in GL chart of account.
    When an maintenance order is settled with KO88 or KO8G the work order value posted cost center and  the value is display in cost center report but not post to GL module in FI.As I notice only good issue or receive to/from work order is posted in GL but not the settlement of work order.Why?
    Between, Kindly advise what are the report or T-code to view the maintenance order is done the settlement and what are the value is settle for maintenance work order?
    Kindly advice under what circumstance when maintenance work order to cost center settlement is posted to GL(FI module)?
    Please advice.
    Thank you.
    KH

    Hi Kiran,
    The error message clearly says that "Cost Center validity starts from 01.10.2014" i.e. in the future period.
    Change the cost center from period in the past date and try.
    BR, Srinivas Salpala

  • FSCM 9.0: COBOL Process GLPPPOST does not post Journal Entry correctly

    Folks,
    Hello. I am workin on FSCM 9.0 General Ledger module. "Edit Journal" is AE program that works correctly. But "Post Journal" is a COBOL program that does not works correctly.
    COBOL process GLPPPOST posts only debit accounts of a Journal entry into table PS_LEDGER but does not post credit accounts of a Journal Entry into table PS_LEDGER. When run the Ledger Report, the report has only column headers and has no data.
    Does FSCM 9.0 have a problem or COBOL process does not work correctly ? Can any folks help me ? Thanks.

    Folks,
    Hello. Thanks a lot for replying.
    I linked my Ledger Group RECORDING with my Business Unit BU01 using "Set Up Financials/Supply Chain > Business Unit Related > Ledgers For A Unit". Then linked UserID VP1 with BU01 in User Preference. I have checked all information about the 3 concepts (VP1, BU01 and RECORDING) and don't see anything wrong.
    I suspect the problem is in the Journal Line page because its Chartfileds belong to 2 SetID (SHARE and FEDRL) and 2 Business Unit (BU01 and BU02).
    When define Chartfields value using "Setup FSC > Common Definition > Design Chartfield > Define Value", I see Chartfields "Fund", "Class" and "Program" with SetID "FEDRL", and other Chartfields with SetID "SHARE". The 2 SetIDs are default in the system.
    Because one Business Unit (BU01) can link to only one SetID (SHARE), I create one more Business Unit BU02 and linked with SetID "FEDRL". Thus, when create a Journal entry using "General Ledger > Journal > Create Journal ", we type in Business Unit (BU01) and Ledger Group (RECORDING) in Header page, but in Line page, some of Chartfields link with SetID SHARE and BU01, and some of Chartfields link with SetID FEDRL and BU02. The journal entry indicates "Inter/Intra Unit Journal". When select "Edit Journal" and click "Process", the message comes up as follows:
    "Ledger Group RECORDING is not valid for Business Unit BU01. Ledger Group defined for this journal is not valid for the Business Unit BU01".
    My question is: That the Chartfields in Journal Line page link with 2 SetIDs and 2 Business Units causes the above error ? Can any folks help ? Thanks.

  • Have loaded lion and now cant access office for mac or apple works as it says it does not support power pc applications, how can I acces them or better still reinstate them please

    Have loaded lion and now can't access office for mac or apple works as it says it does not support power pc applications, how can I acces them or better still reinstate them please?

    MS-Office for Mac versions 2004 and older do not run in Lion since these are PPC-apps for which Apple has dropped support.
    Free alternatives to open Word and Excel files:
    NeoOffice http://www.neooffice.org/neojava/en/index.php
    OpenOffice http://www.openoffice.org/
    Or get the 2011 MS-Office

  • Recently got new iMac with Lion.....when I try to load my LogicPro software, I get 'OS does not support power PC'.  Is there a download to fix or must I spend another 500 on software?

    Recently got new iMac with Lion.....when I try to load my LogicPro software, I get 'OS does not support power PC'.  Is there a download to fix or must I spend another 500 on software?

    What version of Logic do you have?
    And if you end up upgrading, it's only $199 now.

  • Deactivate a depreciation area (Real area but does not post)

    Hi Guys
    I want to deactivate a depreciation area.
    It is a real depreciation area but area does not post in GL.
    Is there any risk in deactivating the depreciation area in the asset class ? We do not want to use this area any more '
    Thanks

    Thanks Anil
    But my question is
    Should I only have  to deactivate the depreciation area in the asset class OAYZ ? In this case new asset won´t see this depreciation area , but old asset still show this depreciation area in AS03. It seems no issue with this approach.
    Someone has suggested me also to deactivate it in OABN (but this depreciation area did not post) If I untick ordinary depreciation field  in OABN when I go to the asset I have an error message:
    "You cannot manage ordinary depreciation in area 60
    Message no. AA656
    Diagnosis
    According to Customizing settings, ordinary depreciation cannot be managed in area 60. The posting being processed changes ordinary depreciation.
    Procedure
    Check the amount entered and the transaction type."
    So, what is the safety procedure just go to OAYZ (I think this is the right way) and unclick the field "deact" ?
    "Indicator: Depreciation area is deactivated
    Set this indicator if you want the depreciation area to be inactive in this asset class or asset (although it is defined in the chart of depreciation)."
    Any other suggestion ?
    Regards

  • After I upgraded to OS x 10.7.5 my Mail account does not post mail, how come?

    After I upgraded to OS x 10.7.5 my Mail account does not post mail, how come?

    No. Tried all that. Server finally says they don't understand what's happening so better if I just delete accounts and set them up again from scratch. Haven't done that yet in hopes someone in the Apple world will have found a solution.

  • [ADF] Focus does not get set on a second level dialog/popup

    Hi,
    While working on a related bug, I've discovered that for every second level dialog/popup(a popup that is invoked from another popup), the focus does not get set to the second level dialog if the first component in that popup is an inputText, unless a user explicitly clicks on it. By focus I mean that on pressing tab, the fields on the previous popup still get selected/highlighted.
    This does not happen if the first UI Component is any other; everything else kept the same. I suspect this is an ADF bug; does anyone know of a workaround?
    Thanks,
    Ravikiran Sastry
    Edited by: 911228 on Jan 30, 2012 11:59 PM

    Hello,
    we are having the same issue using JDeveloper 11.1.1.4 and Internet Explorer 8.
    The code is really simple: just a regular popup with an inputListOfValues component inside. Open the popup, open the inputListOfValue's "Search and Select" popup and if you press the Esc key, the first one will be closed, while the "Search and select" popup will remain there.
    Jordi

  • IMac does not support Power PC. A fix?

    My iMac does not support Power PC. Is there a Reader fix?

    If your Mac is PowerPC the latest version that you can run is Reader 9.4. Adobe stopped ALL development of PowerPC versions of software in November of 2010, and Apple doesn't even support PowerPC Macs or software anymore. It may not be what you want ot here, but your Mac is obsolete.

Maybe you are looking for